August 02, 2023 Ken Peters Senior Vice President Chief Nuclear Officer P.O. Box 1002 Glen Rose, TX 76043
SUBJECT:
VISTRA OPERATIONS COMPANY, LLC - NOTIFICATION OF LICENSE RENEWAL INSPECTION AND REQUEST FOR INFORMATION (05000445/2023012 and 05000446/2023012)
Dear Ken. Peters:
During the weeks of September 11 and September 25, 2023, the Nuclear Regulatory Commission (NRC) will begin a license renewal inspection at your facility. Six inspectors will perform this two-week inspection in accordance with NRC Inspection Procedure 71002, License Renewal Inspection. This inspection focuses on aging management activities to verify that the applicant: (1) identified non-safety-related structures, systems, and components for inclusion within their aging management programs; (2) established aging management program for managing the effects of aging; and (3) ensured aging management programs accurately reflected requirements consistent with in the Generic Aging Lessons Learned Report (GALL Report)
To minimize the inspection impact on the site and to ensure a productive inspection for both parties, we have enclosed a request for information needed for the inspection. It is important that all these documents are up to date and complete to minimize the number of additional documents requested during the preparation and/or the on-site portions of the inspection.
Please provide this information electronically to the lead inspector. The information request has two groups:
The first group lists information necessary for our initial inspection scoping and in-office preparation activities. During the in-office preparation activities, the team will identify as much as possible the information and activities to be reviewed during the inspection.
This information should be provided to the lead inspector by August 21.
The second group includes additional information required for the team to review the selected activities. This information should be available to the team by the first day of the inspection. It is also requested that corrective action documents and/or questions developed during the inspection be provided to the lead inspector as the documents are generated.
K. Peters 2
The schedule for the inspection is as follows:
Offsite Preparation Week: September 5 - September 8, 2023
Onsite Inspection Weeks: September 11-15 & September 25-29, 2023 PAPERWORK REDUCTION ACT STATEMENT This letter contains mandatory information collections that are subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). The Office of Management and Budget (OMB) approved these information collections (approval number 3150-0011). Send comments regarding this information collection to the Information Services Branch, Office of the Chief Information Officer, Mail Stop: T6 A10M, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by e-mail to Infocollects.Resource@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0011) Office of Management and Budget, Washington, DC 20503.
PUBLIC PROTECTION NOTIFICATION The NRC may not conduct nor sponsor, and a person is not required to respond to, a request for information or an information collection requirement unless the requesting document displays a currently valid OMB control number.
This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely, Shiattin T. Makor, Senior Reactor Inspector Engineering Branch 2 Division of Operating Reactor Safety Signed by Makor, Shiattin on 08/02/23
K. Peters 3
Docket No. 05000445 and 05000446 License No. NPF-87 and NPF-89
Enclosure:
1.
License Renewal 71002 Document Request cc w/ encl: Distribution via LISTSERV
SUNSI Review X
Non-Sensitive
Sensitive X
Publicly Available
Non-Publicly Available OFFICE SRI:DORS/EB2 NAME SMakor SIGNATURE
/RA/
DATE 08/02/23 License Renewal Document Requests Inspection Report: 05000445/2023012 and 05000446/2023012 Onsite Inspection Dates:
September 11 - 15, 2023; and September 25 - 29, 2023 Inspection Procedure:
IP 71002 License Renewal Inspection The documents and information requested below should generally be made available to the inspection team for the team's use both on-site and off-site. Electronic format is the preferred media, preferably in a searchable format. Electronic media should contain descriptive names and be indexed and hyperlinked to facilitate ease of use. Information in lists should contain enough information to be easily understood by someone who has knowledge of light water reactor technology. If electronic media is made available via an internet based remote document management system, then the remote document access must allow inspectors to download, save, and print the documents in the NRC's office. Electronic media on compact disc or paper records (hard copy) are acceptable. At the end of the inspection, the documents in the team's possession will not be retained.
This document request is based on typical documents that a generic plant might have. As such, this document request is not meant to imply that any specific plant is required to have all the listed documents. In addition, your plant specific document titles may vary from the document titles listed below. We also request that the information provided be sorted by the list below.
A. Documents requested by August 21, 2023 (prior to on-site inspection) 1.
Provide copies of the program basis document for each aging management program.
2.
License Renewal Application Development Instructions (station blackout, scoping and screening, aging management reviews, operating experience reviews) 3.
License Renewal Process Instructions (developing aging management review report, developing the aging management programs, working with the database) 4.
References specified in the aging management programs, aging management reviews, and scoping and screening processes.
5.
Copy of any license amendment updates and responses to Requests for Additional Information if related to the selected aging management programs or scoping and screening.
6.
A minimum of 10 years of operating experience related to the aging management programs selected.
7.
Issued or draft procedures related to the aging management programs selected.
2 8.
Single set of marked up license renewal drawings (hard copy); size 24 x 36 9.
Provide current management and license renewal organizational charts, electronic copies of the Updated Final Safety Analysis Report, Technical Specifications, Technical Specifications Bases, and Licensee Controlled Specifications.
- 10. Provide copies of any internal/external self-assessments and associated corrective action documents generated in preparation for the inspection.
B. Documents requested for on-site inspection 1.
Contact information for selected inspection samples to facilitate inspector observations and questions.
C. Documents requested through the inspection 1.
Copies of any corrective action documents generated because of the teams questions or queries during this inspection.
2.
Copies of the list of questions submitted by the team members and the status/resolution of the information requested (provide daily during the inspection to each team member).
If you have questions regarding the information requested, please contact the lead inspector.
Inspector Contact Information:
Senior Reactor Inspector 817-200-1507 Shiattin.Makor@nrc.gov Greg Pick (Technical Asst.)
Senior Reactor Inspector 817-200-1207 Greg.Pick@nrc.gov James Mejia Reactor Inspector 817-200-1102 James.Mejia@nrc.gov Ata Istar Civil Engineer 301-415-4049 Ata.Ista@nrc.gov George Wang Civil Engineer 301-415-5862 George.Wang@nrc.gov Andy Johnson Senior Materials Engineer 301-415-1475 Andrew.Johnson@nrc.gov Mailing Address:
U.S. NRC, Region IV Attn: First Last Name 1600 East Lamar Blvd.
Arlington, TX 76011-4511