Category:E-Mail
MONTHYEARML24023A6242024-01-23023 January 2024 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr) Preliminary Safety Analysis Report (PSAR) Section 4.3 Audit Question (4.3-25 on Material Degradation) ML24022A2122024-01-22022 January 2024 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr) Preliminary Safety Analysis Report (PSAR) Section 4.3 Audit Questions (4.3-23 and 4.3-24 on Material Degradation) ML24017A3032024-01-17017 January 2024 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr) Preliminary Safety Analysis Report (PSAR) Section 4.3 Audit Questions (Related to Material Degradation) ML24015A0102024-01-11011 January 2024 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr) Preliminary Safety Analysis Report (PSAR) Section 4.3 Audit Question (Related to Material Degradation) ML24008A0922024-01-0808 January 2024 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr) Preliminary Safety Analysis Report (PSAR) Section 4.3 Audit Questions (Related to Material Degradation) ML23354A2852023-12-20020 December 2023 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr) Preliminary Safety Analysis Report (Psar), Section 4.3 and 9.2 Audit Questions (Related to Material Degradation) ML23348A3732023-12-14014 December 2023 Acu Msrr - Environmental Review Requests for Confirmatory Information - Closure Confirmation for CA- 2, 5 and 6 ML23346A2352023-12-12012 December 2023 Acu Msrr - Environmental Review Requests for Confirmatory Information - Closure Confirmation for NO-2 and 3 ML23345A1702023-12-11011 December 2023 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr) PSAR Chapter 3 Audit Question ML23335A1172023-12-0101 December 2023 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr), Preliminary Safety Analysis Report (PSAR) Chapter 3 Audit Question ML23271A0202023-09-27027 September 2023 Acu Msrr - Environmental Review Requests for Confirmatory Information - Closure Confirmation ML23237B1492023-08-21021 August 2023 Abilene Christian University, Request for Non-Public Documents ML23241A7842023-08-16016 August 2023 Discussion with Texas Historical Commission ML23241A7932023-08-14014 August 2023 Chitimacha Tribe Response 8_14_2023 ML23241A8192023-08-11011 August 2023 Texas Historical Commission Final Response 8_11_2023 ML23241A8312023-08-11011 August 2023 THC Correspondence with Caitlin Brashear as of 8_29 ML23219A2132023-08-0202 August 2023 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr) Section 2.3 Audit Questions (Batch 2) ML23194A1592023-07-13013 July 2023 NRR E-mail Capture - Abilene Christian University (Acu), Molten Salt Research Reactor (Msrr) Chapter 16 Audit Questions ML23194A0642023-07-13013 July 2023 NRR E-mail Capture - Abilene Christian University - Audit Plan for Pre-Submittal Audit Related to Physical Security for the Molten Salt Research Reactor ML23192A4542023-07-11011 July 2023 NRR E-mail Capture - Abilene Christian University (Acu), Molten Salt Research Reactor (Msrr) Chapter 11 Audit Question ML23184A1462023-07-0303 July 2023 NRR E-mail Capture - Abilene Christian University (Acu) Molten Salt Research Reactor (Msrr) Chapter 10 Audit Questions ML23241A8262023-06-12012 June 2023 Texas Historical Commission Response 6_12_2023 ML23241A8142023-06-12012 June 2023 Delaware Nation Response 6_12_2023 ML23241A7862023-05-23023 May 2023 Caddo Nation Response 5_16_23 ML23241A8172023-05-23023 May 2023 Kickapoo Tribe Response 5_23_2023 ML23129A7802023-05-0909 May 2023 NRR E-mail Capture - Abilene Christian University (Acu) Msrr Section 1.7 and 9.5 Audit Questions ML23123A0462023-05-0202 May 2023 NRR E-mail Capture - Abilene Christian University (Acu) Msrr Chapter 13 and Section 9.2 Audit Question ML23123A0442023-05-0202 May 2023 NRR E-mail Capture - Abilene Christian University (Acu) Msrr Chapter 4, Chapter 6, and Section 9.6 Audit Question ML23116A1712023-04-26026 April 2023 NRR E-mail Capture - Abilene Christian University - Audit Questions Regarding Acu CP Chapters 1, 5, 8, 9 (Except 9.2 and 9.6), 10, 11, 12, 14-18, and General Topics (Batch 2) ML23095A0812023-04-0505 April 2023 NRR E-mail Capture - Abilene Christian University - Audit Questions Regarding Acu Construction Permit (CP) Preliminary Safety Analysis Report (PSAR) Chapters 2 and 3 (Batch 2) ML23086A0142023-03-24024 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Questions Regarding Acu CP Chapters 4, 6, and 9.6 ML23086A0172023-03-24024 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Questions Regarding Acu CP PSAR Chapters 2 and 3 (Batch 1) ML23080A1912023-03-21021 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Questions Regarding Acu CP Chapters 1, 5, 8, 9 (Except 9.2 and 9.6), 10, 11, 12, 14-18, and General Topics (Batch 1) ML23076A0152023-03-16016 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Questions Regarding Acu CP Chapters 9.2 and 13 ML23073A3022023-03-14014 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Questions Regarding Acu CP Chapter 7 ML23065A0552023-03-0202 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Plan for the Molten Salt Research Reactor Construction Permit Application Primarily Regarding Chapters 4, 6, and 9.6 ML23065A0482023-03-0202 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Plan for the Molten Salt Research Reactor Construction Permit Application Primarily Regarding Chapters 2 & 3 ML23065A0512023-03-0202 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Plan for the Molten Salt Research Reactor Construction Permit Application Primarily Regarding Chapter 7 ML23065A0522023-03-0202 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Plan for the Molten Salt Research Reactor Construction Permit Application Primarily Regarding Chapters 1, 5, 8, 9 (Except 9.2 and 9.6), 10, 11, 12, 14-18, and General Topics ML23065A0562023-03-0202 March 2023 NRR E-mail Capture - Abilene Christian University - Audit Plan for the Molten Salt Research Reactor Construction Permit Application Primarily Regarding Chapters 9.2 and 13 ML23052A0672023-02-21021 February 2023 NRR E-mail Capture - Abilene Christian University - Audit Question Regarding the Acu CP Technical Topics Audit ML23038A0092023-02-0606 February 2023 NRR E-mail Capture - Abilene Christian University - Audit Questions Regarding the Acu CP Technical Topics Audit 2024-01-08
[Table view] |
Text
From: Edward Helvenston Sent: Thursday, July 13, 2023 1:22 PM To: Rusty Towell; Lester Towell; Benjamin Beasley; Tim Head; Jordan Robison; Alexander Adams Cc: Richard Rivera; Zackary Stone (He/Him/His); Michael Wentzel; Greg Oberson (He/Him); Boyce Travis
Subject:
ACU MSRR Chapter 16 Audit Questions
Dear Dr. Towell,
Below are questions the NRC staff has prepared for Abilene Christian University (ACU) related to the ACU Preliminary Safety Analysis Report, primarily Chapter 16, Other License Considerations. The NRC staff would like to discuss these questions within the scope of the ACU construction permit (CP) application review Audit Plan for Chapters 1, 5, 8, 9 (Except 9.2 and 9.6), 10, 11, 12, 14-18, and General Topics (see audit plan dated 3/2/2023, ML23065A052), and I am providing in advance to facilitate discussion during an audit meeting. We will add this email, with the questions, to public ADAMS. If you have any questions, please let Richard, Zackary, or I know.
Thank you, Ed Helvenston, U.S. NRC Non-Power Production and Utilization Facility Licensing Branch (UNPL)
Division of Advanced Reactors and Non-Power Production and Utilization Facilities (DANU)
Office of Nuclear Reactor Regulation (NRR)
O-6B22 (301) 415-4067 Item # Question 16.1-1 The guidance in ORNL/TM-2020/1478 (ML20219A771), Appendix A, Part 1, Section 16.1, Prior Use of Reactor Components, states that [f]uel provided by the Department of Energy (DOE) for a new facility could come from DOE storage and have a history of prior use that must be considered. The guidance also states that prior use should be considered for fuel salt. PSAR Sections 4.2.1 and 16.1 do not appear to address potential prior use of fuel and/or salt. Please discuss whether the MSRR may utilize fuel and/or salt that were previously used in other reactors. If so, will ACU consider such prior use in its evaluation of the fuel salt that will be used in the MSRR?
16.1-2 PSAR Section 16.1 states that the MSRR will be integrated into a portion of the pre-existing ACU Science and Engineering Research Center (SERC) building and that the weight of the MSRR reactor system will be supported by the SERC research bay floor and systems pit; as such, these portions of the SERC will be SSCs for the MSRR. Please clarify if this description of the portions of the pre-existing SERC that will become safety-related SSCs remains accurate in light of information discussed and provided for audit in response to audit question Gen-7 and questions in the PSAR Chapter 2 and 3 audit.
16.1-3 Please clarify whether ACU plans to use any SERC features which may become MSRR SSCs for other purposes prior to installation of the MSRR. If so, discuss whether and how ACU is considering such prior use in its analysis of the ability of those SSCs to perform their applicable safety function for the MSRR.
Hearing Identifier: NRR_DRMA Email Number: 2165 Mail Envelope Properties (BY5PR09MB59560CF9FAA1C397D0757CC8E037A)
Subject:
ACU MSRR Chapter 16 Audit Questions Sent Date: 7/13/2023 1:21:40 PM Received Date: 7/13/2023 1:21:00 PM From: Edward Helvenston Created By: Edward.Helvenston@nrc.gov Recipients:
"Richard Rivera" <richard.rivera@nrc.gov>
Tracking Status: None "Zackary Stone (He/Him/His)" <Zackary.Stone@nrc.gov>
Tracking Status: None "Michael Wentzel" <Michael.Wentzel@nrc.gov>
Tracking Status: None "Greg Oberson (He/Him)" <Greg.Oberson@nrc.gov>
Tracking Status: None "Boyce Travis" <Boyce.Travis@nrc.gov>
Tracking Status: None "Rusty Towell" <rxt01a@acu.edu>
Tracking Status: None "Lester Towell" <ldt20a@acu.edu>
Tracking Status: None "Benjamin Beasley" <bgb23b@acu.edu>
Tracking Status: None "Tim Head" <tlh07b@acu.edu>
Tracking Status: None "Jordan Robison" <jcr20b@acu.edu>
Tracking Status: None "Alexander Adams" <axa20j@acu.edu>
Tracking Status: None Post Office: BY5PR09MB5956.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 2611 7/13/2023 1:21:00 PM Options Priority: Normal Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date: