ML23192A454

From kanterella
Jump to navigation Jump to search
NRR E-mail Capture - Abilene Christian University (Acu), Molten Salt Research Reactor (Msrr) Chapter 11 Audit Question
ML23192A454
Person / Time
Site: Abilene Christian University
Issue date: 07/11/2023
From: Stone Z
NRC/NRR/DANU
To: Towell R
Abilene Christian University (ACU)
References
Download: ML23192A454 (2)


Text

From:

Zackary Stone (He/Him/His)

Sent:

Tuesday, July 11, 2023 12:41 PM To:

Rusty Towell; Lester Towell; Jordan Robison; Tim Head; Alexander Adams; Benjamin Beasley Cc:

Richard Rivera; Edward Helvenston; Michael Wentzel; Greg Oberson (He/Him); Boyce Travis; Zachary Gran; Edward Stutzcage

Subject:

ACU MSRR Chapter 11 Audit Question

Dear Dr. Towell,

Below is a question the NRC staff has prepared for Abilene Christian University (ACU) related to the ACU Preliminary Safety Analysis Report, Chapter 11, Radiation Protection Program and Waste Management. The NRC staff would like to discuss this question within the scope of the ACU construction permit (CP) application review Audit Plan for Chapters 1, 5, 8, 9 (Except 9.2 and 9.6), 10, 11, 12, 14-18, and General Topics (see audit plan dated 3/2/2023, ML23065A052), and I am providing in advance to facilitate discussion during an audit meeting. We will add this email, with the question, to public ADAMS. If you have any questions, please let Richard, Edward, or I know.

Thank you, Zackary Stone, Project Manger Advanced Reactor Licensing Branch 2 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Item #

Question 11.3-1 In PSAR Section 11.3, ACU indicates that the facility is not subject to the requirements of 10 CFR Part 20, Subpart H. The NRC staff notes that 10 CFR Part 20, Subpart H not only includes requirements for respiratory protection but also requirements for process and engineering controls and other controls to control radiation exposure to airborne radioactive material and is applicable to all licensees. Fission products at the facility include noble gases and other radioactive material that could become airborne. In addition, Table 10.2-3 shows that a gas sample release in the Research Bay would exceed 1 DAC (which is the criteria for an airborne radioactivity area, as defined in 10 CFR 20.1003). While respirators may not need to be used, provided that adequate process, engineering controls, or other measures are implemented to control airborne radioactivity, as needed, the requirements of 10 CFR Part 20, Subpart H are applicable.

The NRC staff requests that ACU clarify the statement in PSAR Section 11.3.

Hearing Identifier:

NRR_DRMA Email Number:

2159 Mail Envelope Properties (SA1PR09MB86871356CA5174C2D20D6D13E131A)

Subject:

ACU MSRR Chapter 11 Audit Question Sent Date:

7/11/2023 12:40:39 PM Received Date:

7/11/2023 12:40:00 PM From:

Zackary Stone (He/Him/His)

Created By:

Zackary.Stone@nrc.gov Recipients:

"Richard Rivera" <richard.rivera@nrc.gov>

Tracking Status: None "Edward Helvenston" <Edward.Helvenston@nrc.gov>

Tracking Status: None "Michael Wentzel" <Michael.Wentzel@nrc.gov>

Tracking Status: None "Greg Oberson (He/Him)" <Greg.Oberson@nrc.gov>

Tracking Status: None "Boyce Travis" <Boyce.Travis@nrc.gov>

Tracking Status: None "Zachary Gran" <Zachary.Gran@nrc.gov>

Tracking Status: None "Edward Stutzcage" <Edward.Stutzcage@nrc.gov>

Tracking Status: None "Rusty Towell" <rxt01a@acu.edu>

Tracking Status: None "Lester Towell" <ldt20a@acu.edu>

Tracking Status: None "Jordan Robison" <jcr20b@acu.edu>

Tracking Status: None "Tim Head" <tlh07b@acu.edu>

Tracking Status: None "Alexander Adams" <axa20j@acu.edu>

Tracking Status: None "Benjamin Beasley" <bgb23b@acu.edu>

Tracking Status: None Post Office:

SA1PR09MB8687.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 1999 7/11/2023 12:40:00 PM Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date: