ND-22-0155, ITAAC Closure Notification on Completion of ITAAC 3.3.00.14 (Index Number 820)

From kanterella
(Redirected from ML22087A446)
Jump to navigation Jump to search

ITAAC Closure Notification on Completion of ITAAC 3.3.00.14 (Index Number 820)
ML22087A446
Person / Time
Site: Vogtle 
Issue date: 03/28/2022
From: Yox M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
ND-22-0155
Download: ML22087A446 (6)


Text

~ Southern Nuclear MAR 2 8 2022 Docket No.:

52-025 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 7825 River Road Waynesboro, GA 30830 706-848-6459 tel ND-22-0155 10 CFR 52.99(c)(1)

ITAAC Closure Notification on Completion of ITAAC 3.3.00.14 [Index Number 820)

Ladies and Gentlemen:

In accordance with 1 O CFR 52.99(c)(1 ), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) of the completion of Vogtle Electric Generating Plant (VEGP) Unit 3 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 3.3.00.14 [Index Number 820).

This ITAAC confirms that a report exists and concludes that the external walls, doors, ceilings, and floors in the main control room, the central alarm station, and the secondary alarm station are bullet-resistant to at least Underwriters Laboratory Ballistic Standard 752, level 4. The closure process for this ITAAC is based on the guidance described in Nuclear Energy Institute (NEI) 08-01, "Industry Guideline for the ITAAC Closure Process Under 1 O CFR Part 52," which was endorsed by the NRC in Regulatory Guide 1.215.

This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 1 O CFR 52.99.

If there are any questions, please contact Kelli Roberts at 706-848-6991.

Respectfully submitted,

~Li '

Michael J. Yox Regulatory Affairs Direc or Vogtle 3 & 4

Enclosure:

MJY/RLB/sfr Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 3.3.00.14 [Index Number 820)

U.S. Nuclear Regulatory Commission ND-22-0155 Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. Peter P. Sena Ill Mr. D. L. McKinney Mr. H. Nieh Mr. G. Chick Mr. S. Stimac Mr. P. Martino Mr. J. B. Williams Mr. M. J. Yox Mr. A. S. Parton Ms. K. A. Roberts Ms. J.M. Coleman Mr. C. T. Defnall Mr. C. E. Morrow Mr. K. J. Drudy Mr. J. M. Fisher Mr. R. L. Beilke Mr. S. Leighty Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:

Nuclear Regulatory Commission Ms. M. Bailey Mr. M. King Mr. G. Bowman Ms. A. Veil Mr. C. P. Patel Mr. G. J. Khouri Mr. C. J. Even Mr. B. J. Kemker Ms. N. C. Coovert Mr. C. Welch Mr. J. Gaslevic Mr. 0. Lopez-Santiago Mr. G. Armstrong Mr. M. Webb Mr. T. Fredette Mr. C. Santos Mr. B. Davis Mr. J. Vasquez Mr. J. Eargle Mr. T. Fanelli Ms. K. Mccurry Mr. J. Parent Mr. B. Griman Mr. V. Hall

U.S. Nuclear Regulatory Commission ND-22-0155 Page 3 of 3 Oglethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Dalton Utilities Mr. T. Bundros Westinghouse Electric Company, LLC Dr. L. Oriani Mr. D. C. Durham Mr. M. M. Corletti Mr. Z. S. Harper Ms. S. L. Zwack Other Mr. S. W. Kline, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GOS Associates, Inc.

Mr. S. Roetger, Georgia Public Service Commission Mr. R. L. Trokey, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. S. Blanton, Balch Bingham

U.S. Nuclear Regulatory Commission ND-22-0155 Enclosure Page 1 of 3 Southern Nuclear Operating Company ND-22-0155 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 3.3.00.14 [Index Number 820]

U.S. Nuclear Regulatory Commission ND-22-0155 Enclosure Page 2 of 3 ITAAC Statement Design Commitment

14. The external walls, doors, ceiling, and floors in the main control room, the central alarm station, and the secondary alarm station are bullet-resistant to at least Underwriters Laboratory Ballistic Standard 752, level 4.

Inspections/Tests/ Analyses Type test, analysis, or a combination of type test and analysis will be performed for the external walls, doors, ceilings, and floors in the main control room, the central alarm station, and the secondary alarm station.

Acceptance Criteria A report exists and concludes that the external walls, doors, ceilings, and floors in the main control room, the central alarm station, and the secondary alarm station are bullet-resistant to at least Underwriters Laboratory Ballistic Standard 752, level 4.

IT AAC Determination Basis A combination of type testing and analysis was performed for the external walls, doors, ceilings, and floors in the main control room (MGR), the central alarm station (GAS), and the secondary alarm station (SAS) to demonstrate that the external walls, doors, ceilings, and floors in the MGR, GAS, and SAS are bullet-resistant to at least Underwriters Laboratory Ballistic Standard 752 (UL 752), level 4 and satisfy the applicable bullet-resisting physical barrier requirements of the VEGP Unit 3 and Unit 4 Physical Security Plan associated with 1 O CFR 73.55(e)(5). The VEGP Unit 3 Plant Security System ITAACs only cover the Unit 3 plant security system design commitment scope.

Type testing was performed on the materials, used to construct the access doors to the MGR, GAS and SAS, to at least UL 752 Level 4 using guidance in Regulatory Guide 5.76 (Reference 1 ). The testing consisted of discharging a weapon using the appropriate caliber ammunition at a sample of the protective material in a controlled environment and inspecting the protective material to ensure protection is provided against complete penetration, passage of fragments of projectiles, and spalling (fragmentation) of the protective material that could cause injury to a person standing directly behind the bullet-resisting barrier.

Analyses were performed to demonstrate that the as-built external walls, floors, and ceilings of the MGR, GAS and SAS meet bullet-resistant criteria. The analyses verified that the as-built attributes of the external walls, floors, and ceilings (e.g., concrete thickness, concrete compressive strength, etc.) meet the design attributes needed to ensure protection is provided against complete penetration, passage of fragments of projectiles, and spalling (fragmentation) of the protective material that could cause injury to a person standing directly behind the bullet-resisting barrier. Penetration openings in the MGR, GAS, and SAS external wall, floor and ceiling structures are either sealed with a high-density sealant, provided with a bullet resistant design (e.g., angled entry with steel shields) preventing direct line of sight to normally occupied areas of the MGR, GAS and SAS, the penetration itself is routed with angles or baffled within the wall, floor, or ceiling structure, or any combination thereof.

U.S. Nuclear Regulatory Commission ND-22-0155 Enclosure Page 3 of 3 The results of the type testing and analyses are documented in IT AAC Technical Report SV3-SES-ITR-800820 (Reference 2) and conclude that the external walls, doors, ceilings, and floors in the main control room, the central alarm station, and the secondary alarm station are bullet-resistant to at least UL 752, level 4.

Reference 2 is available for NRC inspection as part of the Unit 3 ITAAC 3.3.00.14 Completion Package (Reference 3).

ITAAC Finding Review In accordance with plant procedures for ITAAC completion, Southern Nuclear Operating Company (SNC) performed a review of all findings pertaining to the subject ITAAC and associated corrective actions. This review found there were no relevant ITAAC findings associated with this ITAAC. The ITAAC completion review is documented in the ITAAC Completion Package for ITAAC 3.3.00.14 (Reference 3) and is available for NRC review.

ITAAC Completion Statement Based on the above information, SNC hereby notifies the NRC that ITAAC 3.3.00.14 was performed for VEGP Unit 3 and that the prescribed acceptance criteria was met.

Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliant condition in accordance with approved plant programs and procedures.

References (available for NRC inspection)

1. Regulatory Guide 5.76, Physical Protection Programs at Nuclear Power Reactors, July 2009 (Safeguards Information)
2. SV3-SES-ITR-800820, MCR, CAS, SAS Bullet-Resistant Summary Report, Rev O (Security Related Information)
3. 3.3.00.14-U3-CP-Rev0, ITAAC Completion Package