A Southern Nuclear MAR 1 7 2022 Docket No.:

52-025 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Michael J. Yox Regulatory Affairs Vogtle 3 & 4 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 7825 River Road Waynesboro, GA 30830 706-848-6459 tel ND-22-0162 10 CFR 52.99(c)(1)

ITAAC Closure Notification on Completion of ITAAC 2.2.01.06b (Index Number 1031 Ladies and Gentlemen:

In accordance with 10 CFR 52.99(c)(1 ), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) of the completion of Vogtle Electric Generating Plant (VEGP) Unit 3 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.2.01.06b (Index 1031. This ITAAC confirms that the Class 1 E Containment System (CNS) components identified in Combined License (COL)

Table 2.2.1-1 are powered from their respective Class 1E division. The closure process for this ITAAC is based on the guidance described in NEI 08-01, "Industry Guideline for the ITAAC Closure-Process under 10 CFR Part 52," which was endorsed by the NRC in Regulatory Guide 1.215.

This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 10 CFR 52.99.

If there are any questions, please contact Kelli Roberts at 706-848-6991.

Respectfully submitted, Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4

Enclosure:

MJY/LBP/sfr Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.2.01.06b (Index Number 1031

U.S. Nuclear Regulatory Commission ND-22-0162 Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. Peter P. Sena Ill Mr. D. L. McKinney Mr. H. Nieh Mr. G. Chick Mr. S. Stimac Mr. P. Martino Mr. J.B. Williams Mr. M. J. Yax Mr. A. S. Parton Ms. K. A. Roberts Ms. J.M. Coleman Mr. C. T. Defnall Mr. C. E. Morrow Mr. K. J. Drudy Mr. J. M. Fisher Mr. R. L. Beilke Mr. S. Leighty Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE: VND.LI.L06 File AR.01.02.06 Nuclear Regulatory Commission Ms. M. Bailey Mr. M. King Mr. G. Bowman Ms. A. Veil Mr. C. P. Patel Mr. G. J. Khouri Mr. C. J. Even Mr. B. J. Kemker Ms. N. C. Coovert Mr. C. Welch Mr. J. Gaslevic Mr. 0. Lopez-Santiago Mr. G. Armstrong Mr. M. Webb Mr. T. Fredette Mr. C. Santos Mr. B. Davis Mr. J. Vasquez Mr. J. Eargle Mr. T. Fanelli Ms. K. Mccurry Mr. J. Parent Mr. B. Griman Mr. V. Hall

U.S. Nuclear Regulatory Commission ND-22-0162 Page 3 of 3 Oglethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Dalton Utilities Mr. T. Bundros Westinghouse Electric Company, LLC Dr. L. Oriani Mr. D. C. Durham Mr. M. M. Corletti Mr. Z. S. Harper Ms. S.L. Zwack Other Mr. S. W. Kline, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GOS Associates, Inc.

Mr. S. Roetger, Georgia Public Service Commission Mr. R. L. Trokey, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. S. Blanton, Balch Bingham

U.S. Nuclear Regulatory Commission ND-22-0162 Enclosure Page 1 of 5 Southern Nuclear Operating Company ND-22-0162 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.2.01.0Gb [Index Number 103]

U.S. Nuclear Regulatory Commission ND-22-0162 Enclosure Page 2 of 5 ITAAC Statement Design Commitment 6.b) The Class 1E components identified in Table 2.2.1-1 are powered from their respective Class 1 E division.

Inspections/Tests/Analyses Testing will be performed by providing a simulated test signal in each Class 1 E division.

Acceptance Criteria A simulated test signal exists at the Class 1 E equipment identified in Table 2.2.1-1 when the assigned Class 1 E division is provided the test signal.

ITAAC Determination Basis Testing was performed on the Class 1 E components (equipment) identified in the VEGP Unit 3 COL Appendix C Table 2.2.1-1 (Attachment A) to demonstrate they are powered from their respective Class 1 E division. This ITAAC performed testing on the Containment System (CNS) equipment identified in Table 2.2.1-1 by providing a simulated test signal in each Class 1 E division. The Class 1 E electrical penetrations identified in Attachment A are also tested by this ITAAC.

The electrical penetrations identified in Attachment A provide electrical continuity from Class 1 E power supplies Outside Reactor Containment (ORC) to Class 1 E equipment Inside Reactor Containment (IRC) and are not themselves powered components. Multiple Class 1 E component and equipment ITAAC perform Class 1 E power verifications that include power verifications through the electrical penetrations identified in Attachment A.

For the remaining equipment identified in Attachment A, SV3-CNS-ITR-800103 (Reference 1) documents completion of power verification activities from the Protection and Safety Monitoring System (PMS) cabinets and the Class 1 E power distribution panels/motor control centers to the equipment identified in Attachment A. Class 1 E power verification testing of the PMS cabinets, associated with the equipment identified in Attachment A, was verified through applicable portions of ITAAC 2.5.02.05a testing (Reference 2) and confirmed the PMS cabinets are powered from their respective Class 1 E division. Reference 1 first verified that power supply cables/wiring are installed and terminated from the applicable PMS cabinet and Class 1 E power distribution panel/motor control center to the respective component identified in Attachment A using approved construction drawings and cable/wiring termination documentation. Reference 2 then confirmed, via cable/wiring termination inspection documentation, that continuity testing was performed on each of the installed cables/wiring to confirm current flow within the installed cable/wiring. The combination of cable/wiring installation and termination verification, with the installed cable/wiring continuity testing, confirmed that the equipment identified in Appendix A is powered from its respective Class 1 E division.

The Unit 3 technical reports (References 1 and 2) confirm that a simulated test signal exists at the Class 1E equipment identified in Table 2.2.1-1 when the assigned Class 1E division is provided a test signal.

U.S. Nuclear Regulatory Commission ND-22-0162 Enclosure Page 3 of 5 References 1 and 2 are available for NRC inspection as part of Unit 3 ITAAC 2.2.01.06b Completion Package (Reference 3).

ITAAC Finding Review In accordance with plant procedures for ITAAC completion, Southern Nuclear Operating Company (SNC) performed a review of all findings pertaining to the subject ITAAC and associated corrective actions. This review found there are no relevant ITAAC findings associated with this ITAAC.

The ITAAC completion review is documented in the Vogtle Unit 3 ITAAC Completion Package for ITAAC 2.2.01.06b (Reference 3) and is available for NRC inspection.

ITAAC Completion Statement Based on the above information, SNC hereby notifies the NRC that ITAAC 2.2.01.06b was performed for VEGP Unit 3 and that the prescribed acceptance criteria were met.

Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliant condition in accordance with approved plant programs and procedures.

References (available for NRC inspection)

1. SV3-CNS-ITR-800103 Rev. 0, "Unit 3 Containment System (CNS) Class 1 E Equipment Signaled from Assigned Division: ITAAC 2.2.01.06b (NRC Index #103)"
2. SV3-PMS-ITR-800527-1 Rev. 0, "Unit 3 Protection & Safety Monitoring (PMS) System Equipment by Assigned Class 1 E Division: ITAAC 2.5.02.05a"
3. 2.2.01.06b-U3-CP-Rev0, ITAAC Completion Package

U.S. Nuclear Regulatory Commission ND-22-0162 Enclosure Page 4 of 5 Attachment A COL Appendix C Table 2.2.1-1 Equipment Name*

Tag No.*

Instrument Air Supply Outside CAS-PL-V014 Containment Isolation Valve Component Cooling Water System (CCS) Containment Isolation Motor-operated CCS-PL-V200 Valve (MOV) - Inlet Line Outside Reactor Containment (ORC)

CCS Containment Isolation CCS-PL-V207 MOV Outlet Line IRC CCS Containment Isolation CCS-PL-V208 MOV Outlet Line ORC SFS Discharge Line Containment SFS-PL-V038 Isolation MOV ORC SFS Suction Line Containment SFS-PL-V034 Isolation MOV IRC SFS Suction Line Containment SFS-PL-V035 Isolation MOV ORC Containment Purge Inlet VFS-PL-V003 Containment Isolation Valve ORC Containment Purge Inlet VFS-PL-V004 Containment Isolation Valve IRC Containment Purge Discharge VFS-PL-V009 Containment Isolation Valve IRC Containment Purge Discharge VFS-PL-V010 Containment Isolation Valve ORC Vacuum Relief Containment VFS-PL-V800A Isolation A MOV ORC Vacuum Relief Containment VFS-PL-V8008 Isolation B MOV ORC Fan Coolers Return Containment VWS-PL-V082 Isolation Valve IRC Fan Coolers Return Containment VWS-PL-V086 Isolation Valve ORC Fan Coolers Supply Containment VWS-PL-V058 Isolation Valve ORC Reactor Coolant Drain Tank (RCDT)

WLS-PL-V067 Gas Outlet Containment Isolation Valve IRC RCDT Gas Outlet Containment WLS-PL-V068 Isolation Valve ORC Sump Discharge Containment WLS-PL-V055 Isolation Valve IRC

U.S. Nuclear Regulatory Commission ND-22-0162 Enclosure Page 5 of 5 Sump Discharge Containment Isolation Valve - ORC Electrical Penetration P11 Electrical Penetration P12 Electrical Penetration P13 Electrical Penetration P14 Electrical Penetration P15 Electrical Penetration P16 Electrical Penetration P27 Electrical Penetration P28 Electrical Penetration P29 Electrical Penetration P30 Electrical Penetration P31 Electrical Penetration P32

  • Excerpted from COL Appendix C Table 2.2.1-1 WLS-PL-V057 IDSA-EY-P11Z IDSA-EY-P12Y IDSA-EY-P13Y IDSD-EY-P14Z IDSD-EY-P15Y IDSD-EY-P16Y IDSC-EY-P27Z I DSC-EY-P28Y I DSC-EY-P29Y IDSB-EY-P30Z IDSB-EY-P31Y IDSB-EY-P32Y