ML22024A032

From kanterella
Jump to navigation Jump to search

Breakout Questions - Trp 44 - Appendix J
ML22024A032
Person / Time
Site: Oconee  
Issue date: 01/20/2022
From: Angela Wu
NRC/NRR/DNRL/NLRP
To:
Wu A, 301-415-2995
Shared Package
ML22024A002 List:
References
Download: ML22024A032 (1)


Text

ONS SLRA: Breakout Questions SLRA Section B2.1.31, 10 CFR Part 50, Appendix J TRP: 044 Question Number SLRA Section SLRA Page Background / Issue (As applicable/needed)

Discussion Question / Request 1

B2.1.31 N/A Scope of Program program element of GALL-SLR XI.S4 states, in part, [t]he aging effects associated with containment pressure-retaining boundary components within the scope of subsequent license renewal and excluded from Type B or C Appendix J testing must still be managed.

Other programs may be credited for managing the aging effects associated with these components; however, the component and the proposed AMP should be clearly identified.

Scope of Program program element in the ONS AMP basis document of 10 CFR Part 50, Appendix J (SLR-ONS-AMPR-XI.S4, Rev.1) provides a table (Table 4.1-

1) that identifies the penetrations excluded from Type C containment isolation value testing and provides the AMPs that are credited with managing the applicable aging effects. However, it appears that the in-scope components excluded from Type B (containment penetration leak rate) testing and proposed AMPs are not mentioned.

Please identify the in-scope components that are excluded from Type B testing, and associated AMPs credited for managing the aging effects in keeping with Scope of Program element of GALL-SLR XI.S4.