Surry Power Station Updated Final Safety Analysis Report Chapter 4
Intentionally Blank Intentionally Blank
Revision 52Updated Online 09/30/20 SPS UFSAR 4-i 4.1 DESIGN BASES..................................................
4.1-1 4.1.1 Performance Objectives...........................................
4.1-1 4.1.2 Design Criteria..................................................
4.1-1 4.1.2.1 Quality Standards...............................................
4.1-1 4.1.2.2 Performance Standards..........................................
4.1-2 4.1.2.3 Records Requirements...........................................
4.1-2 4.1.2.4 Missile Protection..............................................
4.1-2 4.1.2.5 Reactor Coolant Pressure Boundary................................
4.1-2 4.1.2.6 Monitoring Reactor Coolant Leakage...............................
4.1-2 4.1.2.7 Reactor Coolant Pressure Boundary Capability.......................
4.1-2 4.1.2.8 Reactor Coolant Pressure Boundary Rapid Propagation Failure Prevention.
4.1-3 4.1.2.9 Reactor Coolant Pressure Boundary Surveillance......................
4.1-3 4.1.3 Design Characteristics.............................................
4.1-4 4.1.3.1 Design Pressure................................................
4.1-4 4.1.3.2 Design Temperature.............................................
4.1-4 4.1.3.3 Seismic Loads.................................................
4.1-4 4.1.4 Cyclic Loads....................................................
4.1-5 4.1.5 Service Life.....................................................
4.1-6 4.1.6 Codes And Classifications.........................................
4.1-6 4.1.7 Irradiation Surveillance Program....................................
4.1-8 4.1.7.1 General Description.............................................
4.1-8 4.1.7.2 Measurement of Integrated Fast Neutron (E Greater than 1.0 MeV) Flux at the Irradiation Samples.............................................
4.1-12 4.1.7.3 Calculation of Integrated Fast Neutron (E Greater than 1.0 Mev) Flux at the Irradiation Samples.............................................
4.1-15 4.1.7.4 Measurement of the Initial RTNDT of the Reactor Pressure Vessel Baseplate and Forgings Material...............................................
4.1-17 4.1 References........................................................
4.1-19 4.2 SYSTEM DESIGN AND OPERATION................................
4.2-1 4.2.1 General Description...............................................
4.2-1 4.2.2 Components.....................................................
4.2-1 4.2.2.1 Reactor Vessel.................................................
4.2-1 4.2.2.2 Pressurizer....................................................
4.2-5 4.2.2.3 Steam Generators...............................................
4.2-6 4.2.2.4 Reactor Coolant Pumps..........................................
4.2-9 Chapter 4: Reactor Coolant System Table of Contents Section Title Page
Revision 52Updated Online 09/30/20 SPS UFSAR 4-ii Chapter 4: Reactor Coolant System Table of Contents (continued)
Section Title Page 4.2.2.5 Pressurizer Relief Tank..........................................
4.2-11 4.2.2.6 Piping........................................................
4.2-12 4.2.2.7 Small Valves..................................................
4.2-13 4.2.2.8 Loop Stop Valves..............................................
4.2-13 4.2.3 Pressure-Relieving Devices.........................................
4.2-14 4.2.4 Protection Against Proliferation of Dynamic Effects.....................
4.2-16 4.2.5 Materials of Construction..........................................
4.2-16 4.2.6 Maximum Heat-Up and Cooldown Rates..............................
4.2-18 4.2.7 Leakage........................................................
4.2-19 4.2.7.1 Leakage Detection..............................................
4.2-19 4.2.7.2 N-16 Primary to Secondary Leakage Detection System.................
4.2-20 4.2.7.3 Leakage Prevention.............................................
4.2-21 4.2.7.4 Locating Leaks.................................................
4.2-21 4.2.8 Water Chemistry.................................................
4.2-21 4.2.9 Reactor Coolant Flow Measurements.................................
4.2-22 4.2.9.1 Secondary Heat Balance.........................................
4.2-22 4.2.9.2 Elbow Tap Differential Pressure...................................
4.2-22 4.2.9.3 Experience....................................................
4.2-22 4.2.9.4 Low-Flow Trip Setpoint.........................................
4.2-23 4.2.10 Loose Parts Monitoring System.....................................
4.2-23 4.2.10.1 Design Criteria.................................................
4.2-23 4.2.10.2 System Description.............................................
4.2-24 4.2.11 Loss of Decay Heat Removal.......................................
4.2-24 4.2 References........................................................
4.2-26 4.2 Reference Drawings.................................................
4.2-27 4.3 SYSTEM DESIGN EVALUATION...................................
4.3-1 4.3.1 Safety Factors...................................................
4.3-1 4.3.1.1 Reactor Vessel.................................................
4.3-1 4.3.1.2 Steam Generators...............................................
4.3-5 4.3.1.3 Steam Generator Tube Vibration Considerations......................
4.3-6 4.3.1.4 Piping Quality Assurance........................................
4.3-6 4.3.2 Reliance on Interconnected Systems..................................
4.3-7 4.3.3 System Integrity.................................................
4.3-7 4.3.3.1 Reactor Coolant Pump Flywheel Integrity...........................
4.3-8
Revision 52Updated Online 09/30/20 SPS UFSAR 4-iii Chapter 4: Reactor Coolant System Table of Contents (continued)
Section Title Page 4.3.3.2 Pressurized Thermal Shock.......................................
4.3-9 4.3.4 Overpressure Protection...........................................
4.3-10 4.3.4.1 Operational Conditions..........................................
4.3-10 4.3.4.2 Air Supply....................................................
4.3-11 4.3.5 System Accident Potential.........................................
4.3-12 4.3.6 Redundancy.....................................................
4.3-12 4.3 References........................................................
4.3-12 4.4 TESTS AND INSPECTIONS........................................
4.4-1 4.4.1 Reactor Coolant System Inspection..................................
4.4-1 4.4.1.1 Non-destructive Inspection of Materials and Components...............
4.4-1 4.4.1.2 Electroslag Weld Quality Assurance................................
4.4-2 4.4.1.3 Continuous Drive Friction Weld Process............................
4.4-4 4.4.1.4 Reactor Coolant System Field Erection and Welding...................
4.4-5 4.4.1.5 Reactor Coolant System Cleanliness................................
4.4-5 4.4.1.6 Reactor Coolant System Testing Following Opening...................
4.4-5 4.4.1.7 Inservice Inspection Capability....................................
4.4-5
Revision 52Updated Online 09/30/20 SPS UFSAR 4-iv Table 4.1-1 Reactor Coolant System Pressures.............................
4.1-23 Table 4.1-2 Reactor Vessel Design Data..................................
4.1-24 Table 4.1-3 Pressurizer and Pressurizer Relief Tank Design Data..............
4.1-25 Table 4.1-4 Steam Generator Design Data (Per Steam Generator)..............
4.1-26 Table 4.1-5 Reactor Coolant Pump Design Data...........................
4.1-27 Table 4.1-6 Reactor Coolant Piping Design Data...........................
4.1-28 Table 4.1-7 Loop Stop Valves..........................................
4.1-28 Table 4.1-8 Thermal and Loading Cycles.................................
4.1-29 Table 4.1-9 Reactor Coolant System - Code Requirements...................
4.1-30 Table 4.1-10 Capsule Specimen Data, Unit 1...............................
4.1-31 Table 4.1-11 Capsule Specimen Data, Unit 2...............................
4.1-32 Table 4.1-12 Surveillance Capsule Withdrawal Schedulea for Surry Unit 1.......
4.1-33 Table 4.1-13 Surveillance Capsule Withdrawal Schedulea for Surry Unit 2.......
4.1-34 Table 4.1-14 Unit 1 Reactor Pressure Vessel Toughness Data (Unirradiated)d.....
4.1-35 Table 4.1-15 Unit 2 Reactor Pressure Vessel Toughness Data (Unirradiated)......
4.1-38 Table 4.2-1 Reactor Coolant System Materials of Construction................
4.2-28 Table 4.2-2 Reactor Coolant System Water Chemistry Specificationsa..........
4.2-30 Table 4.2-3 Radiation-Induced Increase in Transition Temperature for A302B Steel................................
4.2-31 Table 4.3-1 Summary of Estimated Primary-Plus-Secondary Stress Intensity for Components of the Reactor Vessel - Unit 1......................
4.3-15 Table 4.3-2 Summary of Estimated Primary-Plus-Secondary Stress Intensity for Components of the Reactor Vessel - Unit 2......................
4.3-15 Table 4.3-3 RTPTS Values for Surry Unit 1...............................
4.3-16 Table 4.3-4 RTPTS Values for Surry Unit 2...............................
4.3-17 Table 4.4-1 Reactor Coolant System Quality Assurance Program..............
4.4-6 Chapter 4: Reactor Coolant System List of Tables Table Title Page
Revision 52Updated Online 09/30/20 SPS UFSAR 4-v Figure 4.1-1 Typical Surveillance Capsule, Elevation View..................
4.1-41 Figure 4.1-2 Installed Surveillance Capsule, Plan View.....................
4.1-42 Figure 4.2-1 Reactor Coolant System (Unit 1).............................
4.2-33 Figure 4.2-2 Reactor Vessel Schematic (Unit 1)...........................
4.2-34 Figure 4.2-3 Reactor Vessel Schematic (Unit 2)...........................
4.2-35 Figure 4.2-4 Pressurizer..............................................
4.2-36 Figure 4.2-5 Steam Generator Tube-to-Tubesheet Juncture...................
4.2-37 Figure 4.2-6 Typical Reactor Coolant Pump..............................
4.2-38 Figure 4.2-7 Reactor Coolant Pump Estimated Performance Characteristics.....
4.2-39 Figure 4.2-8 Reactor Coolant Loop Stop Valve............................
4.2-40 Figure 4.2-9 Radiation Induced Increase In Transition Temperature for a 302-B Steel...............................
4.2-41 Figure 4.2-10 Containment Air Particulate Monitor Response Time as a Function of Percentage of Failed Fuel and Rate of Coolant Leakage.........
4.2-42 Figure 4.2-11 Containment Gas Monitor Minimum Time to Detect Leak.........
4.2-43 Figure 4.3-1 Reactor Vessel Stress Evaluation Sheet 1......................
4.3-18 Figure 4.3-2 Reactor Vessel Stress Evaluation Sheet 2......................
4.3-19 Figure 4.3-3 Reactor Coolant Pump Flywheel Dimensions...................
4.3-20 Figure 4.3-4 Reactor Coolant Pump Flywheel Stresses......................
4.3-21 Chapter 4: Reactor Coolant System List of Figures Figure Title Page
Revision 52Updated Online 09/30/20 SPS UFSAR 4-vi Intentionally Blank
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-1 CHAPTER 4 REACTOR COOLANT SYSTEM 4.1 DESIGN BASES Note: As required by the Renewed Operating Licenses for Surry Units 1 and 2, issued March 20, 2003, various systems, structures, and components discussed within this chapter are subject to aging management. The programs and activities necessary to manage the aging of these systems, structures, and components are discussed in Chapter 18.
4.1.1 Performance Objectives The reactor coolant system transfers the heat produced by the nuclear reaction in the core to the steam generators, where steam is generated to drive the turbine generator. Borated demineralized light water is circulated at the flow rate and temperature consistent with achieving the reactor core thermal-hydraulic performance presented in Section 3.4. The water also acts as a neutron moderator, a reflector, and a solvent for the neutron absorber.
The reactor coolant system provides a boundary for containing the primary coolant under operating temperature and pressure conditions. It serves to confine radioactive material and limits its uncontrolled release to the secondary system and to the other parts of the unit. During transient operation, the system heat capacity attenuates thermal transients generated by the core or extracted by the steam generators. The reactor coolant system accommodates coolant volume changes within the protection system criteria both during normal operation and during anticipated transient conditions.
The thermal-hydraulic effects resulting from loss of power to the reactor coolant pumps are reduced to acceptable levels by appropriate selection of the inertia of the reactor coolant pumps so that core damage does not result. The layout of the system ensures natural circulation capability following a loss-of-flow incident to permit cooldown without overheating the core.
A portion of the reactor coolant system piping is used by the safety injection system to deliver cooling water to the core for emergency core cooling during a loss-of-coolant accident (LOCA).
4.1.2 Design Criteria 4.1.2.1 Quality Standards Quality standards of material selection, design, fabrication, and inspection conform to the applicable provisions of recognized codes and good nuclear practice (Section 4.1.6). Details of the quality assurance test procedures and inspection acceptance levels are given in Sections 4.3.1 and 4.4. Particular emphasis is placed on the quality assurance of the reactor vessel
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-2 4.1.2.2 Performance Standards All piping, components, and supporting structures are designated and designed as Seismic Class I components, and are designed to withstand the jet thrust forces of a pipe rupture1. Details are given in Section 4.1.3.
4.1.2.3 Records Requirements Records of the design, fabrication, quality control, and construction of the major reactor coolant system components and the related engineered safety features components are maintained by or are available to Vepco throughout the station life.
4.1.2.4 Missile Protection The dynamic effects of a pipe rupture accident1 and other postulated accidents have been evaluated in the detailed layout and design of the high-pressure equipment and missile barriers.
The design ensures the missile protection necessary to maintain functional capability.
4.1.2.5 Reactor Coolant Pressure Boundary The reactor coolant system, with its control and protective provisions, accommodates the pressures and temperatures attained under all expected modes of station operation or anticipated system interactions, and maintains the stresses within applicable code stress limits (Section 4.3.1).
4.1.2.6 Monitoring Reactor Coolant Leakage Positive indications in the control room of leakage of coolant from the reactor coolant system to the containment are provided by equipment that permits continuous monitoring of the containment internal pressure, temperature, and gaseous and particulate activity; of containment sump water level; of makeup water to the primary system; and of the temperature of water leaking from the reactor vessel through its head flange. This equipment provides information that is indicative of a basic level of leakage from primary systems and components. Any increase observed may be indicative of an increase in the leakage rate from the reactor coolant system. The equipment provided is capable of monitoring such a change. Refer to Section 4.2.7.
4.1.2.7 Reactor Coolant Pressure Boundary Capability The reactor coolant pressure boundary is capable of accommodating, without rupture, the loads resulting from a sudden reactivity insertion such as results from rod ejection. Details of this analysis are provided in Section 14.3.3.
The operation of the reactor is such that the severity of an ejection accident is inherently limited. Since control rod assemblies are used to control load variations only, and core depletion is followed with boron dilution, only the control rod assemblies in the controlling groups are
- 1. As discussed in Section 4.1.3 and Section 15.6.2, it is no longer necessary to consider the dynamic effects of postulated rupture of the primary reactor coolant loop piping. However, other pipe ruptures as discussed in Section 15.6.2 must still be considered.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-3 inserted in the core at power, and at full power these rods are only partially inserted. A rod insertion limit monitor is provided as an administrative aid to the operator to ensure that this condition is met.
The reactor design is such that the maximum fuel temperature for the highest-worth ejected rod is below the threshold for resultant damage to the primary system pressure boundary.
The failure of a rod mechanism housing, causing a control rod assembly to be rapidly ejected from the core, is evaluated as a theoretical but not credible accident. While limited fuel damage could result from this hypothetical event, the fission products would be confined to the reactor coolant system and the reactor containment. The environmental consequences of rod ejection would be less severe than from the hypothetical LOCA, for which public health and safety is shown to be adequately protected.
4.1.2.8 Reactor Coolant Pressure Boundary Rapid Propagation Failure Prevention The probability of a rapid propagation type failure is remote. The reactor coolant pressure boundary is designed to reduce to an acceptable level the probability of this type of failure.
In the core region of the reactor vessel it is expected that the notch toughness of the material will change as a result of fast neutron exposure. This change is evidenced as a shift in the reference temperature for the nil ductility transition (RTNDT) which is factored into the operating procedures. The RTNDT shift of the vessel material and welds, due to radiation effects, is monitored by an integrated surveillance program that conforms with the requirements of 10 CFR 50, Appendix H and ASTM E 185, and is described in Section 4.1.7.
All pressure-containing components of the reactor coolant system are designed, fabricated, inspected, and tested in conformance with the applicable codes. Further details are given in Section 4.1.6.
The reactor vessel closure heads were replaced with closure heads with impact properties that exceed the original head requirements. The low alloy steels have an RTNDT of less than 10°F for Unit 1 and -60°F for Unit 2. The analysis which satisfies 10 CFR 50, Appendix G is less limiting than that assumed in the development of the Technical Specification pressure/temperature limit curves. Therefore, the Technical Specification pressure/temperature limit curves will not change.
4.1.2.9 Reactor Coolant Pressure Boundary Surveillance The design of the reactor vessel and its arrangement in the system provides the capability for accessibility during service life to all the internal surfaces of the vessel and to certain external zones of the vessel, including the nozzle to reactor coolant piping welds and the top and bottom heads. The reactor arrangement within the containment provides sufficient space for inspection of the external surfaces of the reactor coolant piping, except for the area of pipe within the primary shielding concrete.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-4 4.1.3 Design Characteristics 4.1.3.1 Design Pressure The reactor coolant system design and operating pressure, the safety, power relief, and pressurizer spray valve design setpoints, and the protection system pressure setpoints are listed in Table 4.1-1. The design pressure allows for operating transient pressure changes. The selected design margin considers core thermal lag, coolant transport times and pressure drops, instrumentation and control response characteristics, and system relief valve characteristics. The design pressures and data for the respective system components are listed in Tables 4.1-2 through 4.1-7.
4.1.3.2 Design Temperature The design temperature for each component is selected to be above the maximum coolant temperature in that component under all normal and anticipated transient load conditions. The design and operating temperatures of the respective system components are listed in Tables 4.1-2 through 4.1-7.
4.1.3.3 Seismic Loads The seismic loading conditions are established by the operating-basis earthquake (OBE) and design-basis earthquake (DBE). The ground acceleration values and the basis for their selection are presented in Section 2.5. The seismic analysis of the reactor coolant system is described in more detail in Appendix 15A.
For the OBE loading condition, the nuclear steam supply system is capable of continued safe operation. Therefore, for this loading condition, critical structures and equipment are required to operate within allowable code stress limits. The seismic design for the design-basis earthquake provides a margin that ensures the capability to shutdown and maintain the nuclear facility in a safe condition. In this case, it is only necessary to ensure that the reactor coolant system components are able to perform their safety function. This has come to be referred to as the no-loss-of-function criterion and the loading condition as the no-loss-of-function earthquake loading condition.
The criteria adopted for allowable stresses and stress intensities in vessels and piping subjected to normal loads plus seismic loads are defined in Section 15A.
To further ensure against accident aggravation, the reactor coolant system has been checked for the combination of stresses associated with the design-basis earthquake and the most severe pipe rupture loadings on the reactor coolant system.1 These stress loadings are designed to be below the limits assumed to cause rupture, as illustrated in Section 15A.
- 1. As discussed in Section 15.6.2, it is no longer necessary to consider the dynamic effects of postulated rupture of the primary reactor coolant loop piping. However, other pipe ruptures as discussed in Section 15.6.2 must still be considered.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-5 For the combination of normal and operating-basis earthquake loadings, the stresses in the support structures are designed to be within the limits of the applicable codes as discussed in Section 15A.
For the combination of normal and operating-basis earthquake loadings, and for the combination of these loads plus the most severe on the primary reactor coolant system due to postulated pipe rupture loadings1, the stresses in the support structures are limited to values that ensure structural integrity and maintain the component stresses within the limit previously established.
4.1.4 Cyclic Loads All components in the reactor coolant system are designed to withstand the effects of cyclic loads due to reactor coolant system temperature and pressure changes. These cyclic loads are introduced by normal power changes and reactor trip, start-up, and shutdown operations. The number of thermal and loading cycles used for design purposes are given in Table 4.1-8. Heatup and cooldown rates are limited as indicated in Section 4.2.6.
The number of cycles for unit heatup and cooldown at 100°F/hr was selected as a conservative estimate based on an evaluation of the expected requirements. The resulting number, which averages five heatup and cooldown cycles per year and was based on the original license period of 40 years, could be increased significantly; however, it is intended to represent a conservative realistic number rather than the maximum allowed by the design. This estimate has been retained for the 60-year renewed operating license period.
Although loss-of-flow and loss-of-load transients are not included in the tabulation, since the tabulation is intended to represent only normal design transients, the effects of these transients have been analytically evaluated and are included in the fatigue analysis for primary system components.
The reactor coolant system and its components are designed to accommodate 10% of full-power step changes in station load and 5% of full-power-per-minute ramp changes over the range from 15% full power up to and including, but not exceeding, 100% of full power without reactor trip. Automatic rod withdrawal is disabled. The station loading from 15% to 100% is accomplished by manual control rod withdrawal. Operator action will be needed to restore the station parameters to the reference values on design basis load increase transients. The reactor coolant system accepts a complete loss of load from full power with reactor trip. In addition, the steam dump system makes it possible to accept a 50% load rejection from full power without reactor trip.
- 1. As discussed in Section 15.6.2, it is no longer necessary to consider the dynamic effects of postulated rupture of the primary reactor coolant loop piping. However, other pipe ruptures as discussed in Section 15.6.2 must still be considered
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-6 4.1.5 Service Life The service life of reactor coolant system pressure components depends upon the material irradiation, unit operational thermal cycles, quality manufacturing standards, environmental protection, and adherence to established operating procedures.
The reactor vessel is the only component of the reactor coolant system that is exposed to a significant level of neutron irradiation. It is therefore the only component that is subject to any appreciable material irradiation effects. These effects are discussed in Section 4.1.7.
Reactor vessel design is based on the transition temperature method of evaluating the possibility of brittle fracture of the vessel material as a result of operations. The service life of the reactor coolant system components, as required by the ASME Code,Section III, for Class A vessels, is established for the 60-year design life. These operating conditions include the cyclic application of pressure loadings and thermal transients listed in Table 4.1-8.
4.1.6 Codes And Classifications All pressure-containing components of the reactor coolant system are designed, fabricated, inspected, and tested in conformance with the applicable codes listed in Table 4.1-9.
The reactor coolant system is classified as Class I for seismic design. The load combinations for Class I design are described in Chapter 15.
The Westinghouse Equipment Specification for the reactor vessel contains many requirements that are supplemental to those specified in ASME Code,Section III. These requirements include the following:
- 1. Design
- a. Design pressures and temperatures have been selected to be above pressures and temperatures that would be expected to occur under all normal and transient conditions.
- b. A complete fatigue analysis was performed on the entire vessel.
- 2. Inspection and Quality Assurance
- a. In addition to the normal straight-beam ultrasonic examination required by the ASME Code, all pressure boundary plate material was examined by the angle-beam ultrasonic method.
- b. All weld deposit overlay cladding used for the vessel corrosion resistant lining was 100%
ultrasonically inspected to verify that the cladding is bonded to the base metal.
- c. After the vessel hydrostatic test, all vessel and head internal surfaces were liquid penetrant inspected, and all external surfaces were magnetic particle inspected.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-7
- d. Prior to placing the vessel in service, an ultrasonic examination of pressure boundary welds was performed in accordance with the ASME Code for inservice inspection of nuclear reactor coolant systems.
- e. In addition to the ASME Code-required third-party inspector, Westinghouse provided full-time quality assurance coverage in the Babcock & Wilcox Co. shop, and also in the Rotterdam Dockyard (RDM) shop during the fabrication of the Surry vessels.
- f. In addition to the quality assurance coverage provided by Westinghouse, Vepco and the architect-engineer, Stone & Webster, performed regular quality assurance audits of reactor vessel fabrication as performed by RDM.
Unit 1 Reactor Vessel Closure Head was replaced with a closure head fabricated and manufactured in accordance with the French Construction Code (R-CCM) 1993 Edition with 1st Addenda June 1994, 2nd Addenda June 1995, 3rd Addenda June 1996 and Modification Sheets FM 797, 798, 801, 802, 803, 804, 805, 806, and 807. The sizing calculations and the stress and fatigue analysis were performed to ASME B&PV Code,Section III, 1995 Edition 1996 Addenda.
The Design Report (Reference 14) certified that the closure head meets the design requirements and stress limits for the ASME B&PV Code,Section III, 1995 Edition addenda through 1996, except as noted below.
Exception: The CRDM Adapter Tube Assembly includes a friction weld at the bimetallic joint between the housing flange and the tube. The use of friction welds in the fabrication of vessels and piping is not in accordance with the requirements of Section III of the ASME Boiler and Pressure Vessel Code. Consideration of this weld as a Category B full penetration weld in the stress analysis is justified in the Report of Reconciliation (Reference 15) for the Surry Unit 1 replacement reactor vessel closure head.
The Unit 2 reactor vessel closure head was replaced with a closure head fabricated and manufactured by Mitsubishi Heavy Industries (MHI). The replacement reactor vessel closure head was designed and fabricated in accordance with ASME B&PV Code,Section III, 1995 Edition with 1996 Addenda. The stress and fatigue analyses were performed to ASME B&PV Code,Section III, 1995 Edition with 1996 Addenda. The Mitsubishi Heavy Industries Design Specification, Reference 16, for the Unit 2 reactor vessel head contains many requirements that are supplemental to those specified in ASME Code,Section III. These requirements include the following:
- 1. Design
- a. Design pressures and temperatures have been selected to be above the pressures and temperatures that would be expected to occur under all normal and transient conditions.
- b. A complete fatigue analysis was performed on the entire head.
- 2. Inspection and Quality Assurance
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-8
- a. All weld deposit overlay cladding used for head corrosion resistant lining was 100%
ultrasonically inspected to verify that the cladding is bonded to base metal.
- b. The final non-destructive examination of the pressure boundary materials was conducted in the following:
(1) Low alloy materials were magnetic particle examined after final machining of the reactor vessel head.
(2) Surfaces that are clad were magnetic particle examined prior to cladding.
(3) Surfaces were magnetic particle examined after removal of temporary attachments.
4.1.7 Irradiation Surveillance Program 4.1.7.1 General Description In the surveillance program (References 4 & 5) the evaluation of the radiation damage is based on pre-irradiation testing of Charpy V-notch and tensile specimens, and post-irradiation testing of Charpy V-notch and tensile specimens. Wedge opening loading (WOL) fracture mechanics test specimens are also irradiated for potential supplemental testing. This program is directed toward evaluation of the effect of radiation on the fracture toughness of reactor vessel steels based on the transition temperature approach and the fracture mechanics approach, and is in accordance with ASTM-E-185, Recommended Practice for Surveillance Tests on Structural Materials in Nuclear Reactors. Low melting point alloys are included as thermal control specimens. They provide indication if the area of surveillance has exceeded a given temperature.
The reactor vessel surveillance program uses eight specimen capsules, more than the minimum number recommended by ASTM-E-185. The capsules are located about 3 inches from the vessel wall, directly opposite the center portion of the core. Elevation and plan views showing the location and dimensional spacing of the capsules with relation to the core, thermal shield, and vessel and weld seams are shown in Figures 4.1-1 and 4.1-2, respectively. The capsules can be removed or relocated when the vessel head and upper internals are removed. The capsules contain specimens of some of the materials found in the Surry reactor vessel. These specimens include material from the shell plates located in the core region of the reactor and associated weld metal and heat-affected-zone metal. (As part of the surveillance program, a report of the residual elements in weight percent to the nearest 0.01% will be made for surveillance material base metals and as deposited weld metal.) In addition, 8 Charpy specimens in each of the surveillance capsules are made from fully documented specimens of SA533 Grade B correlation monitor material obtained through Subcommittee II of ASTM Committee E10, Radioisotopes and Radiation Effects. The eight Unit 1 capsules contain approximately 32 tensile specimens, 240 Charpy V-notch specimens (which include weld metal and heat-affected-zone material), and 40 WOL specimens. The eight Unit 2 capsules contain a total of 32 tensile specimens, 352 Charpy V-notch specimens (which include weld metal and heat-affected-zone material), and 32 WOL specimens.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-9 The dosimeters permit evaluation of the flux seen by the specimens and vessel wall. In addition, thermal monitors made of low-melting alloys are included to monitor temperature of the specimens. The specimens are enclosed in a tight-fitting stainless steel sheath to prevent corrosion and ensure good thermal conductivity. The complete capsule is helium leak tested. Vessel material sufficient for additional capsules is kept in storage should the need arise for additional replacement test capsules in the program.
The anticipated degree to which the specimens will perturb the fast neutron flux and energy distribution will be considered in the evaluation of the surveillance specimen data. Verification and possible readjustment of the calculated wall exposure will be made by use of data on all capsules withdrawn.
Specimen data for Unit 1 capsules are given in Table 4.1-10. Specimen data for Unit 2 capsules are given in Table 4.1-11. The schedule for removal and reinsertion of capsules is shown on Table 4.1-12 (Unit 1) and Table 4.1-13 (Unit 2). Irradiated surveillance capsules which do not require testing to satisfy ASTM E-185 are designated as standby capsules. There currently is no detailed regulatory guidance regarding the treatment of standby capsules that are removed but not tested. To address this concern, all surveillance capsules placed in storage will be maintained for possible future insertion. If one or more capsules will not be maintained in such a way as to permit future insertion, then the NRC staff will be notified of this change.
Irradiation of the specimens is higher than the irradiation of the adjacent vessel wall because they are closer to the core than the vessel itself. Since these specimens experience higher irradiation and are actual samples from the materials used in the vessel, the RTNDT measurements are representative of the vessel at a later time in life. Data from fracture toughness samples (WOL) are expected to provide additional information for use in determining allowable stresses for irradiated material, if required.
The reactor vessel surveillance capsule holders are located at 15, 25, 35, and 45 degrees relative to the core symmetry, as shown in Figure 4.1-2.
The unirradiated reference temperature for the nil ductility transition (RTNDT) for a material may be determined either by large specimen drop weight tests or by Charpy V-notch impact tests.
The unirradiated RTNDT is the higher of (a) the nil ductility transition temperature as determined by drop weight test, or (b) the temperature at which Charpy test specimens exhibit at least 50 ft-lb of absorbed energy and 35 mils of lateral expansion, minus 60°F. RTNDT values for irradiated materials are calculated in the manner prescribed by Regulatory Guide 1.99, Revision 2, Radiation Embrittlement of Reactor Vessel Materials using data from the rector vessel material surveillance program.
Framatome ANP Topical Report BAW-2308, Revision 1-A (Reference 17) provides an alternate method for determining the adjusted RTNDT (reference nil-ductility temperature) of the Linde 80 weld materials present in the beltline region of the reactor pressure vessels at Surry Power Stations Unit 1 and 2. Topical Report BAW-2308, Revision 1-A, also provides revised
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-10 initial (unirradiated) RTNDT values and initial (unirradiated) uncertainty terms for the Linde 80 weld materials present in the reactor pressure vessels of Surry Units 1 and 2. Topical Report BAW-2308, Revision 1-A was approved by the NRC in August 2005.
The alternative initial reference temperature values provided in Topical Report BAW-2308, Revision 1-A are obtained by using the B&W Owners Group Master Curve reference temperature database and ASME Code Case N-629. As described in Topical Report BAW-2308, Revision 1-A, previous initial RTNDT values for Linde 80 class of weld materials were determined by the 50 ft-lb Charpy impact energy according to NB-2331 of Section III of the ASME B&PV Code, which gave overly conservative initial RTNDT values.
The Master Curve methodology permits establishment of a reference temperature, T0, using direct fracture toughness testing of compact tension (CT) specimens ranging in size from 0.5-inch thickness CTs (0.5T-CTs) to 2.0T-CTs, and precracked Charpy-sized bend specimens, based on ASTM standard Test Method E 1921. The value of T0 is statistically related to the temperature at which fracture toughness specimens from a given weld wire heat exhibited a median fracture toughness of
, which is equivalent to
. The Master Curve method therefore represents an alternative to the indirect tests of fracture toughness using drop weight and Charpy V-notch testing per ASME Code Section III, Paragraph NB-2331, which are used to establish values of RTNDT.
Topical Report BAW-2308, Revision 1-A concludes that the use of initial (unirradiated) reference temperature values and appropriate uncertainty terms for certain Linde 80 weld materials, based on Master Curve method and ASME Code Case N-629, provide an acceptable alternate means of predicting irradiation induced shift in fracture toughness when the RTNDT-based irradiation induced shift models of Regulatory Guide 1.99, Revision 2 are employed.
NRC approved use of Topical Report BAW-2308, Revision 1-A subject to certain conditions and limitations delineated in the final safety evaluation attached to Reference 17.
By letter dated February 5, 2007, the PWROG submitted Topical Report BAW-2308, Revision 2, Initial RTNDT of Linde 80 Weld Materials, to NRC for review. The intent of Topical Report BAW-2308, Revision 2, was to supplement Topical Report BAW-2308, Revision 1-A, by addressing two of the NRC imposed conditions. NRC has determined that Topical Report BAW-2308, Revision 2 is acceptable for referencing in licensing applications to the extent specified in the final safety evaluation attached to Reference 23.
ASME Section XI Appendix G provides guidance for translating the value of RTNDT into a K value, representative of the materials resistance to fracture. Normal operation and hydrostatic test pressure/temperature operating limits which satisfy the requirements of 10 CFR 50 Appendix G are established on the basis of linear-elastic fracture mechanics theory, such that thermal and pressure stresses will not result in combined stresses in excess of the materials resistance to fracture (K). Because the normal operating temperature of the reactor vessel is well 100 MPa m 90 ksi in
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-11 above the RTNDT of the limiting reactor vessel beltline material, brittle fracture during normal operation is not considered to be a credible mode of failure.
The allowable pressures are revised periodically according to the schedule in the reactor vessel surveillance program. The revised curves are based upon the experimentally determined fluence from the last analyzed capsule, and a conservative fluence projection for the next scheduled capsule withdrawal. The use of an RTNDT which includes the projected change in RTNDT due to irradiation provides additional conservatism for the non-irradiated components of the reactor coolant system.
Virginia Power has been a member of the Babcock and Wilcox Owners Group (B&WOG)
Reactor Vessel Working Group (RVWG). Surry Units 1 and 2 are participants in the RVWGs Master Integrated Reactor Vessel Surveillance Program (MIRVSP) (Reference 8). The program integrates (a) the plant specific reactor vessel surveillance programs of the participants, (b) the existing supplemental B&W Owners Group irradiation capsules, (c) additional supplemental irradiation capsules to assure the availability of high fluence and thermal annealing data for the participants reactor vessels, (d) existing test reactor irradiation data sources, and (e) provisions for additional test reactor irradiation data sources. The objectives of the MIRVSP are as follows:
- 1. Provide a unified power reactor data base for Linde 80 welds necessary to perform the analysis required by 10 CFR 50, Appendix G for materials that may exhibit < 50 ft-lb Charpy upper-shelf energy.
- 2. Maximize the effectiveness of data sharing among participants to assure that required data is available to all participants for current and extended plant operation.
- 3. Provide the materials, specimens, irradiation capsules, and power reactor irradiation sites required to obtain data that can be used to evaluate the thermal annealing process.
- 4. Minimize testing of redundant capsules (those which do not provide useful information) in existing plant-specific RVSPs to ensure optimum utilization of data sources.
- 5. Simplify the licensing process by providing a single document that covers the RVSP integration and capsule withdrawal schedules and which can be referenced in each utilitys design documentation.
The MIRVSP does not reduce the number of required capsules in the plant-specific programs, nor does it eliminate the requirement that an acceptable reactor vessel fluence monitoring program be maintained. An integrated program must meet the criteria enumerated in 10 CFR 50, Appendix H, Paragraph III.C.
These criteria and considerations are satisfied by the MIRVSP approach (Reference 9). The Surry 1 and 2 plant-specific surveillance capsule withdrawal schedules presented in Tables 4.1-12 and 4.1-13 are consistent with the guidelines of the MIRVSP as described above. Standby Capsules U, S, and Y (Unit 1) and T and Z (Unit 2) are available to satisfy potential fluence monitoring requirements during the 20-year license renewal period.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-12 4.1.7.2 Measurement of Integrated Fast Neutron (E Greater than 1.0 MeV) Flux at the Irradiation Samples The Surry Units 1 & 2 surveillance program capsules contain passive neutron flux monitors made of U-238, Np-237, Co-Al, Cu, Ni, Cadmium-shielded Co-Al, and Fe. The iron, nickel, copper, and cobalt-aluminum monitors, in wire form, are placed in holes drilled in spacers at several axial levels within the capsules. Cadmium-shielded neptunium and uranium fission monitors are accommodated within a dosimeter block located near the center of the capsule.
The use of passive monitors does not yield a direct measure of the energy dependent flux level at the point of interest. Rather, the activation or fission process is a measure of the integrated effect that the time-and energy-dependent neutron flux has on the target material over the course of the irradiation period. An accurate assessment of the average neutron flux level incident on the various monitors may be derived from the activation measurements only if the irradiation parameters are well known. In particular, the following variables are of interest:
- The operating history of the reactor
- The energy response of the monitor
- The neutron energy spectrum at the monitor location
- The physical characteristics of the monitor The analysis of the passive monitors and subsequent derivation of the average neutron flux requires completion of two procedures. First, the disintegration rate of product isotope per unit mass of monitor must be determined. Second, in order to define a suitable spectrum averaged reaction cross section, the neutron energy spectrum at the monitor location must be calculated.
The specific activity of each of the monitors is determined using established ASTM procedures. Following sample preparation, the activity of each monitor is determined by means of a lithium-drifted germanium, Ge(Li), gamma spectrometer. The overall standard deviation of the measured data is a function of the precision of sample weighing, the uncertainty in counting, and the acceptable error in detector calibration. For the samples removed from Surry Units 1 & 2 the overall 2s deviation in the measured data is determined to be +/-10%. The neutron energy spectra are determined analytically using the method described in Section 4.1.7.3.
Having the measured activity of the monitors and the neutron energy spectra at the locations of interest, the calculation of the neutron flux proceeds as follows.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-13 The reaction product activity in the monitor is expressed as:
where:
R
= induced product activity No
= Avagadros number A
= atomic weight of the target isotope fi
= weight fraction of the target isotope in the target material Y
= number of product atoms produced per reaction (E) = energy-dependent reaction cross section
ø(E) = time-averaged energy-dependent neutron flux at the monitor location with the reactor at full power Pj
= average core power level during irradiation period j Pmax = maximum of reference core power level
= decay constant of the product isotope tj
= length of irradiation period j td
= decay time following irradiation period j Cj
= ø(E > 1.0 MeV) during irradiation period j divided by the average ø(E > 1.0 MeV) over the total irradiation period. Cj is calculated with the adjoint neutron transport method and accounts for the change in neutron monitor response caused by core power distribution variations from cycle to cycle. Pj/Pmax, which accounts for the month-by-month variation of power level within a cycle, is applied to the full-power-based flux ratio, Cj.
Since neutron flux distributions are calculated using multigroup transport methods and, further, since the prime interest is in the fast neutron flux above 1.0 MeV, spectrum-averaged reaction cross sections are defined such that the integral term in the reaction product activity equation (above) is replaced by the following relation.
R No A
fiY E
( ) E
( )
Pj Pmax
Cj 1 e
j t
(
)
j i
=
N
e d
t E
=
E
( ) E
( )
E d
E E
1.0Mev
(
)
=
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-14 where:
Thus, the equation for the reaction product activity in the monitor noted above is rewritten or, solving for the neutron flux, The total fluence above 1.0 Mev is then given by:
where:
tj = total effective full power seconds of reactor operations up to the time of capsule removal An assessment of the thermal neutron flux levels within the surveillance capsules is obtained from the bare and cadmium-covered Co59 (n, ) Co60 data by means of cadmium ratios and the use of a 37-barn, 2200 m/sec cross section. Thus:
where:
D is defined as:
E
( ) E
( )
E d
0
E
( ) E d
1.0 Mev
gg G
1
=
N
g G
G1.0Mev
=
N
=
=
R No A
fiY E 1.0 Mev
(
)
Pj Pmax
Cj 1 e t
- j
(
)e t
- d j
1
=
N
=
E 1.0Mev
(
)
R No A
fi Y Pj Pmax
Cj 1 e t
- j
(
)e t
- d j
1
=
N
=
E 1.0Mev
(
)
E 1.0Mev
(
)
Pj Pmax
tj j
1
=
N
=
Pj Pmax j
1
=
N
Th Rbare D
1 D
No A
fiY Pj Pmax
Cj 1 e t
- j
(
)e t
- d j
1
=
N
=
R bare RCd covered
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-15 4.1.7.3 Calculation of Integrated Fast Neutron (E Greater than 1.0 Mev) Flux at the Irradiation Samples Knowledge of the neutron environment within the pressure vessel-surveillance capsule geometry is required as an integral part of LWR pressure vessel surveillance programs for two reasons. First, in the interpretation of radiation-induced property changes observed in materials test specimens, the neutron environment (fluence, flux) to which the test specimens were exposed must be known. Second, in relating the changes observed in the test specimens to the present and future condition of the reactor pressure vessel, a relationship between the environment at various positions within the reactor vessel and that experienced by the test specimens must be established.
The former requirement is normally met by employing a combination of rigorous analytical techniques and measurements obtained with passive neutron flux monitors contained in each of the surveillance capsules. The latter information, on the other hand, is derived solely from analysis.
This section describes a discrete ordinates Sn transport analysis performed for the Surry Units 1 & 2 reactor to determine the fast neutron (E > 1.0 Mev) flux and fluence as well as the neutron energy spectra within the reactor vessel and surveillance capsules; and, in turn, to develop data for use in relating neutron exposure of the pressure vessel to that of the surveillance capsules.
A plan view of the Surry reactor geometry at the core midplane is shown in Figure 4.1-2.
Eight irradiation capsule holders attached to the thermal shield are included in the design to support the reactor vessel surveillance program (References 4 & 5). The capsules were originally located at 45°, 55°, 65°, 165°, 245°, 285°, 295°, and 305° relative to the major axis at 0°.
An axial and plan view of a single surveillance capsule attached to the thermal shield is shown in Figure 4.1-1. The stainless steel specimen container is 1-inch square and approximately 3 feet in height. The containers are positioned axially such that the specimens are centered on the core midplane, thus spanning the central 3 feet of the 12-foot high reactor core.
From a neutronic standpoint, the surveillance capsule structures are significant. In fact, they have a marked impact on the distributions of neutron flux and energy spectra in the water annulus between the thermal shield and the reactor vessel. Thus, in order to properly ascertain the neutron environment at the test specimen locations, the capsules themselves must be included in the analytical model. Use of at least a two-dimensional computation is, therefore, mandatory.
Fast neutron fluence (E > 1.0 MeV) analyses (References 18 & 19) were performed in support of the transition to integral fuel burnable absorber (IFBA) for Surry Units 1 and 2, and the removal of flux suppression inserts for Unit 1. The neutron fluence analyses are valid to a cumulative core exposure of 48 Effective Full Power Years for both units. Core power distributions for use in the plant specific fluence evaluations for Surry Units 1 and 2 are derived from measured assembly and cycle burnups for operating cycles 1 through 19 for Unit 1, and cycles 1 through 18 for Unit 2. The fluence evaluations reflect the low leakage fuel management strategies employed in previous operating cycles, and also include the rated thermal power uprate
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-16 from 2441 MWt to 2546 MWt. Future operating cycles were assumed to be representative of reload core designs with integral fuel burnable absorber and without flux suppression inserts. A capacity factor of 95% was assumed to be representative of future operation.
The primary tool used in the determination of the flux and fluence exposure to the reactor vessel and surveillance capsules is the two-dimensional discrete ordinates transport code DORT (Reference 2). The neutron fluence analysis is divided into seven tasks: (1) generation of the neutron source, (2) development of the DORT geometry models, (3) calculation of the macroscopic material cross sections, (4) synthesis of the results, and (5-7) estimation of the calculational bias, the calculational uncertainty, and the final fluence.
The time-averaged space and energy-dependent neutron sources were calculated for the previous cycles explicitly modeled in the fluence evaluations. The effects of burnup on the spatial distribution of the neutron source were accounted for by calculating the cycle average fission spectrum for each fissile isotope on an assembly-by-assembly basis, and by determining the cycle-average specific neutron emission rate. This data was then used with the normalized time weighted average pin-by-pin relative power density (RPD) distribution to determine the space and energy-dependent neutron source. The azimuthally averaged, time averaged axial power shape in the peripheral assemblies was used with the fission spectrum of the peripheral assemblies to determine the neutron source for the DORT analyses.
The BUGLE-93 (Reference 3) cross section library was used for the neutron fluence analyses. The BUGLE-93 library is an ENDF/B-VI based data set produced specifically for light water reactor applications.
The system geometry is approximated using a combination of two-dimensional DORT models. The radial plane DORT model, (R,), encompasses a plane bounded radially by the center of the core and extending through the reactor vessel wall and into the concrete shield, and azimuthally by the major axis at 0° and the adjacent 45° radius. The vertical plane DORT model, (R, ), encompasses a plane bounded axially by the upper and lower grid plates, and radially by the center of the core and a vertical line within the concrete shield. For the Unit 1 cycles where flux suppression inserts were modeled, the DORT models were further refined into multiple axial regions due to the asymmetric flux distribution.
The cross sections, geometry, and appropriate neutron sources were combined to create a set of DORT neutron transport models (R,) and (R, ) for the analysis. Each (R,) and (R, )
DORT run utilized a cross section Legendre expansion of three (P3), at least forty-eight directions (S8), with the appropriate boundary conditions. The DORT analyses produce two sets of two-dimensional flux distributions, one for a vertical plane (R, ), and one for the radial plane (R,), for each set of dosimetry.
Under the assumption that the three-dimensional neutron flux is a separable function, both two-dimensional data sets were mathematically combined to estimate the flux at all three-dimensional points (R,,) of interest.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-17 The neutron fluence evaluations documented in References 18 and 19 were performed by Framatome ANP with acceptable methods that are in compliance with NRC Regulatory Guide 1.190, Calculational and Dosimetry Methods for Determining Pressure Vessel Neutron Fluence. Compliance with NRC Regulatory Guide 1.190 requires that fluence values must be unbiased best-estimate calculations with a well-defined uncertainty. The neutron fluence analyses of References 18 and 19 meet these conditions, with a calculational uncertainty (1) of less than or equal to 15 percent.
The fluence values used in References 18 and 19 have been determined to conservatively bound the more recently developed fluence analyses that explicitly consider the effects of a Measurement Uncertainty Recapture (MUR) uprated core power level (2597 MWth).
The neutron fluence evaluations documented in References 32 and 33 were performed by Westinghouse Electric Company. The fluence projections from Framatome ANP are more conservative than the Westinghouse fluence projections.
4.1.7.4 Measurement of the Initial RTNDT of the Reactor Pressure Vessel Baseplate and Forgings Material The temperature at which a material transitions from failure by ductile tearing to failure by brittle fracture is known as the Reference Temperature for the Nil Ductility Transition (RTNDT).
The unirradiated RTNDT is the higher of (a) the nil-ductility transition temperature (NDTT or TNDT) as determined by drop weight test, or (b) the temperature at which Charpy test specimens exhibit at least 50 ft-lb of absorbed energy and 35 mils of lateral expansion, minus 60°F. The unirradiated (or initial) NDTT for the pressure vessel baseplate and forged materials was determined in accordance with ASTM requirements in place at the time of the original design and licensing of Surry Units 1 and 2. Drop weight and Charpy V-notch testing was performed in accordance with the then-applicable versions of ASTM E208 and ASTM E23, respectively.
The quantity identified as TNDT in Tables 4.1-14 and 4.1-15 is defined in the version of ASTM E208 applicable at the original design and licensing of Surry Units 1 and 2 as the temperature at which a specimen is broken in a series of tests in which duplicate no-break performance occurs at 10°F higher temperature. Using the Charpy V-notch test, the NDTT is defined as the temperature at which the energy required to break the specimen is a certain fixed value. For SA 533B Class 1 and A 508 Class 2 steel, the ASME III Table N-421 specifies an energy value of 30 ft-lb. This value is based on a correlation with the drop weight test and is referred to as the 30 ft-lb-fix. A curve of the temperature versus energy absorbed in breaking the specimen is plotted. To obtain this curve, 15 tests are performed, which include three tests at five different temperatures. The intersection of the energy versus temperature curve with the 30 ft-lb ordinate is designated as the NDTT.
The available data indicate differences as great as 40° between curves plotted through the minimum and average values, respectively. The determination of NDTT from the average curve is
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-18 considered representative of the material and is consistent with procedures as specified in ASTM E23. In assessing the NDTT shift due to irradiation, the translation of the average curve is used.
As part of the Westinghouse surveillance program referred to above, Charpy V-notch impact tests, tensile tests, and fracture mechanics specimens are taken from the core region plates and forgings, and core region weldments including heat-affected-zone material. The test locations are similar to those used in the tests by the fabricator at the plate mill.
The uncertainties of measurement of the baseplate NDTT are:
- 1. Differences in Charpy V-notch ft-lb values at a given temperature between specimens.
- 2. Variation of impact properties through plate thickness.
The fracture toughness technology for pressure vessels and correlation with service failures based on Charpy V-notch impact data is based on the averaging of data. The Charpy V-notch 30-ft-lb fix temperature is based on multiple tests by the material supplier, the fabricator, and by Westinghouse as part of the surveillance program. The average of sets of three specimens at each test temperature is used in determining each of five data points (total of 15 specimens). In the review of available data, differences of 0°F to approximately 40°F are observed in comparing curves plotted through the minimum and average values, respectively. The value of NDTT derived from the average curve is judged to be representative of the material because of the averaging of at least 15 data points, consistent with the specified procedures of ASTM E23. In the case of the assessment of NDTT shift due to fast neutron flux, the displacement of transition curves is measured. The selection of maximum, minimum, or average curves for this assessment is not significant since like curves are used.
There are quantitative differences between the NDTT measurements at the surface, one-quarter thickness (1/4-T), or center of a plate. The NDTT from 1/4-T to the center in heavy plates is observed to vary from improvement in the NDTT to increases up to 85°F. The NDTT at the surface is measured to be as much as 85°F lower than at 1/4-T.
The 1/4-T location is considered conservative since the enhanced metallurgical properties of the surface are not used for the determination of NDTT. In addition, the limiting NDTT for the reactor vessel after operation is based on the NDTT shift due to irradiation. The design value of NDTT after irradiation is assessed at the tip of an assumed quarter-thickness flaw for purposes of establishing Reactor Coolant System (RCS) pressure/temperature operating limits.
Data have been accumulated on the variation of NDTT across heavy section steels at Westinghouse, Nuclear Energy Systems. Similarly, an evaluation of properties of pressure vessel steels in plates 6 to 12 inches thick has been sponsored by the Pressure Vessel Research Committee. Data show NDTT differences between 1/4-T and center of less than 20°F. The criterion of using NDTT + 60°F at the 1/4-T location without taking advantage of the enhanced properties at the surface of reactor vessel plates is conservative.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-19 To assess any possible uncertainties in the consideration of NDTT shift for welds, heat-affected zones, and base metals, test specimens of these three material types are included in the reactor vessel surveillance program.
Additional information is available in References 4 and 5, which were submitted to the NRC by Vepco letter dated January 23, 1978, and in References 6 and 7 which were sent to the NRC by letters dated May 22, 1987 and December 15, 1987, respectively. Data obtained from Surry Unit 1 Capsule X is provided in Reference 20, which was sent to the NRC by letter dated June 18, 1998. Data obtained from Surry Unit 2 Capsule Y is provided in Reference 21, which was sent to the NRC by letter dated March 27, 2003. Additional information concerning upper shelf energy and chemical composition is reported in References 10, 11, and 12. Although Reference 12 considered higher cumulative core burnups (effective full power years, EFPY) than the values assumed in the pressure/temperature limits and the low temperature overpressure protection system (LTOPS) enable temperature, the then-existing Technical Specification bases were considered conservative, and were not revised to take credit for the additional margin.
References 24 and 25 extended the cumulative core burnup applicability limit for the pressure/temperature limits and low temperature overpressure protection system (LTOPS) enabling temperature to 48 EFPY, and included consideration of Measurement Uncertainty Recapture (MUR) uprate.
4.1 REFERENCES
- 1. A. L. Lowe, Jr., Reactor Pressure Vessel and Surveillance Program Materials Licensing Information for Surry Units 1 and 2, BAW-1909, March 1986.
- 2. Rutherford, M. A., Hassan, N. M. et al., Eds., DORT, Two Dimensional Discrete Ordinates Transport Code, BWNT-TM-107, Framatome ANP, Lynchburg, Virginia, May 1995.
- 3. Ingersoll, D. T., et al., BUGLE-93, Production and Testing of the VITAMIN-B6 Fine Group and the BUGLE-93 Broad Group Neutron/photon Cross-Section Libraries Derived from ENDF/B-VI Nuclear Data, ORNL-DLC-175, Radiation Safety Information Computational Center, Oak Ridge National Laboratory, Oak Ridge, Tennessee, April 1994.
- 4. Virginia Electric and Power Company, Surry Unit No. 1, Reactor Vessel Radiation Surveillance Program, WCAP-7723.
- 5. Virginia Electric and Power Company, Surry Unit No. 2, Reactor Vessel Radiation Surveillance Program, WCAP-8805.
- 6. S. E. Yanichko, et al., Analysis of Capsule V from the Virginia Electric and Power Company, Surry Unit 1, Reactor Vessel Radiation Surveillance Program, WCAP-11415, dated February 1987.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-20
- 7. S. E. Yanichko, et al., Analysis of Capsule V from the Virginia Electric and Power Company, Surry Unit 2, Reactor Vessel Radiation Surveillance Program, WCAP-11499, dated June 1987.
- 8. L. S. Harbison, Master Integrated Reactor Vessel Surveillance Program, BAW-1543, Revision 4, dated February 1993. Also Supplement 5 dated December 2003.
- 9. Letter from NRC to J. S. Holm (Framatome ANP), Final Safety Evaluation for Babcock and Wilcox Owners Group Topical Report BAW-1543(NP), Revision 4, Supplement 5, Supplement to the Master Integrated Reactor Vessel Surveillance Program (TAC No. MC1762), dated May 16, 2005.
- 10. M. J. DeVan, et al: Response to Closure Letters to Generic Letter 92-01, Revision 1, BAW-2222, dated June 1994.
- 11. Letter from L. N. Hartz, (Virginia Power) to USNRC, Virginia Electric and Power Company, Surry Power Station Units 1 and 2, Supplement to Response to NRC Request for Additional Information (RAI) on Generic Letter 92-01, Revision 1, Supplement 1, Serial No.99-034, dated February 24, 1999.
- 12. Letter from L. N. Hartz to USNRC, Virginia Electric and Power Company, North Anna Power Station Units 1 and 2, Surry Power Station Units 1 and 2, Evaluation of Reactor Vessel Materials Surveillance Data, Serial No. 99-452A, dated November 19, 1999.
- 13. Letter from NRC to Virginia Electric and Power Company, dated October 1, 2002, Docket Nos. 50-280 and 50-281, Safety Evaluation by the Office of Nuclear Reactor Regulation, Inservice Inspection Relief Requests SR-27, SR-28, SR-32, and SR-33.
- 14. Framatome ANP Document No. 33-1011607, Surry Unit 1 Replacement Reactor Vessel Closure Head Design Report.
- 15. Framatome ANP Document No. 51-5026905, Surry 1 RV Closure Head Report of Reconciliation.
- 16. Mitsubishi Heavy Industries, LTD., Design Report DG KCS-03-0003, Dominion Generation, Surry Power Station Unit 2, Design Report (RVCH), Rev. 3.
- 17. Framatome ANP Topical Report BAW-2308, Revision 1-A, Initial RTNDT of Linde 80 Weld Materials, dated August 2005.
- 18. Framatome ANP Report 32-5068629-00, Surry Unit 1 Updated Fluence Calculation -
Cycles 1 to 19, July 2005.
- 19. Framatome ANP Report 32-5070607-00, Surry Unit 2 Fluence Calculation - Cycles 1 to 18, September 2005.
- 20. Framatome Report BAW-2324, Analysis of Capsule X Virginia Power Surry Unit 1 - Reactor Vessel Material Surveillance Program, April 1998.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-21
- 21. Westinghouse WCAP-16001, Revision 0, Analysis of Capsule Y from Dominion Surry Unit 2 Reactor Vessel Radiation Surveillance Program, February 2003.
- 22. Framatome ANP Report BAW-2494, Revision 1, Low Upper-Shelf Toughness Fracture Mechanics Analysis of Reactor Vessel of Surry Units 1 and 2 for Extended Life through 48 Effective Full Power Years, September 2005.
- 23. Framatome ANP Topical Report BAW-2308, Revision 2-A, Initial RTNDT of Linde 80 Weld Materials, March 24, 2008.
- 24. Letter from L. N. Hartz (Dominion) to NRC, Virginia Electric and Power Company (Dominion), Surry Power Station Units 1 and 2, License Amendment Request, Measurement Uncertainty Recapture Power Uprate, Serial No.09-223, January 27, 2010.
- 25. Letter to D. A. Heacock (Dominion) from K. Cotton (USNRC), Surry Power Station, Unit Nos. 1 and 2, Issuance of Amendments Regarding Measurement Uncertainty Recapture Power Uprate (TAC Nos. ME3293 and ME3294), Dominion Serial No.10-580, dated September 24, 2010.
- 26. Letter from J. A. Price to USNRC, Virginia Electric and Power Company (Dominion), Surry Power Station Units 1 and 2, Revised Reactor Vessel Materials Surveillance Capsule Withdrawal Schedules - UFSAR Change, Serial No.09-507, dated October 26, 2009.
- 27. Letter from J. A. Price to USNRC, Virginia Electric and Power Company (Dominion), Surry Power Station Units 1 and 2, Revised Reactor Vessel Materials Surveillance Capsule Withdrawal Schedules - UFSAR Change, Serial No. 09-507A, dated September 13, 2010.
- 28. Letter from J. A. Price to USNRC, Virginia Electric and Power Company (Dominion), Surry Power Station Units 1 and 2, Revised Reactor Vessel Materials Surveillance Capsule Withdrawal Schedules - UFSAR Change, Serial No.10-721, dated January 3, 2011.
- 29. Letter to D. A. Heacock (Dominion) from K. Cotton (USNRC), Surry Power Station, Unit Nos. 1 and 2 - Safety Evaluation for Revision to Reactor Vessel Surveillance Capsule Withdrawal Schedule (TAC NOS. ME4133 and ME4134), Serial No.11-064, dated January 31, 2011.
- 30. Letter from J. A. Price to USNRC, Surry Power Station Units 1 and 2, License Amendment Request Revised Cumulative Core Burnup Applicability Limit for Heatup and Cooldown Curves, low Temperature Overpressure Protection System (LTOPS) Setpoint and LTOPS Enable Temperature, dated May 6, 2010.
- 31. Letter from Karen Cotton to (USNRC) to D. A. Heacock, Surry Power Station Unit Nos. 1 and 2, - Issuance of Amendments Regarding Reactor Vessel Heatup and Cooldown Curves For 48 effective Full-Power Years (TAC Nos. ME3920 and ME3921), Serial No.11-322, dated May 31, 2011.
- 32. CN-REA-08-74, Pressure Vessel Neutron Fluence Evaluation to Support the MUR for Surry Unit 1, July 29, 2009.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-22
- 33. CN-REA-08-75, Pressure Vessel Neutron Fluence Evaluation to Support the MUR for Surry Unit 2, July 30, 2009.
- 34. WCAP-18028-NP, Revision 0, Extended Beltline Pressure Vessel Fluence Evaluations Applicable to Surry Unit 1 and 2, September 2015.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-23 Table 4.1-1 REACTOR COOLANT SYSTEM PRESSURES Pressure (psig)
Hydrostatic test pressure 3107 Design pressure 2485 Safety valves (open) 2485 High-pressure trip setpoint 2370 Power relief valves (open) 2335 High-pressure alarm 2310 Pressurizer spray valves (open) 2260 Operating pressure (at pressurizer) 2235 Low-pressure alarm 2210 Low-pressure trip setpoint 1885
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-24 Table 4.1-2 REACTOR VESSEL DESIGN DATA Design pressure 2485 psig Operating pressure 2235 psig Hydrostatic test pressure 3107 psig Design temperature 650°F Overall height of vessel and closure head 40 ft. 5 in.
Water volume, with core and internals in place Approximately 3720 ft3 Thickness of insulation, vessel & flange 3 in. (nominal)
Thickness of insulation, reactor closure head dome 5 in.a (nominal)
Number of reactor closure head studs 58 Diameter of reactor closure head studs 6 in.
I.d. of flange 149.7205 in. (Unit 1) 149.563 in. (Unit 2)
O.d. of flange 184 in.
I.d. at shell 157 in.
Inlet nozzle i.d.
Tapered 27.437 to 35.406 in.
Outlet nozzle i.d.
28.97 in. straight Clad thickness, minimum 0.1968 in. (Unit 1) 0.125 in. (Unit 2)
Lower head thickness, minimum 5 in.b Vessel belt-line thickness, minimum 7.875 in.b Closure head thickness, minimum 6.286 in.c (Unit 1) 6.188 in.b (Unit 2)
Reactor coolant inlet temperature (100% power) 536.7 - 542.9°F Reactor coolant outlet temperature (100% power) 603.3 - 609.1°F Reactor coolant flow (100.8 - 101.6) x 106 lb/hr
- a. Some areas at tangent points are less than 5 in.
- b. Not including 0.125-inch minimum thickness of cladding.
- c. Not including 0.1968 minimum thickness of cladding.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-25 Table 4.1-3 PRESSURIZER AND PRESSURIZER RELIEF TANK DESIGN DATA Pressurizer Design pressure 2485 psig Operating pressure 2235 psig Hydrostatic test pressure 3107 psig Design/operating temperature 680/653°F Water volume, 100% power 780 ft3 a Steam volume, 100% power 520 ft3 Surge line nozzle diameter 14 in.
Shell i.d.
84 in.
Minimum shell thickness 4.1 in.
Minimum clad thickness 3/16 in.
Electric heaters capacity (total) 1300 kW Heatup rate of pressurizer using heaters only 55 °F/hr Power-operated pressurizer relief valves Number 2
Opening pressure 2335 psig Capacity, saturated steam/valve (maximum) 210,000 lb/hr (nominal) 179,000 lb/hr Pressurizer safety valves Number 3
Opening pressure 2485 psig ASME rated flow 293,330 lb/hr Pressurizer Relief Tank Design pressure 100 psig Rupture disk (or safety head) relief pressure 100 psig Design temperature 340°F Normal water temperature 120°F Standby water volume 900 ft3 Total volume 1300 ft3 Rupture disk (or safety head) total relief capacity 900,000 lb/hr Number of rupture disks 2
- a. Contents at 60% of net internal volume = 100% power.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-26 Table 4.1-4 STEAM GENERATOR DESIGN DATA (PER STEAM GENERATOR)
Number of steam generators per unit 3
Design pressure, reactor coolant/steam 2485/1085 psig Reactor coolant hydrostatic tested pressure (tube side) 3107 psig Hydrostatic test pressure (shell side) 1356 psig Design temperature, reactor coolant/steam 650/600°F Reactor coolant flow (33.6 - 33.9) x 106 lb/hr Total heat transfer surface area 51,500 ft2 Heat transferred at 100% load 2968 x 106 Btu/hr Steam conditions at 100% load, outlet nozzle Steam flow (3.86 - 3.87) x 106 lb/hr Steam temperature (509.2 - 518.3)°F Steam pressure 738.9 - 800.3 psia Feedwater temperature at 100% load 452.0°F Overall height 67 ft. 8 in.
Shell o.d., upper/lower 178/135 in.
Shell thickness 2.9 in.
Number of U-tubes 3342 U-tube o.d.
0.875 in.
Tube wall thickness (average) 0.050 in.
Number of manways/i.d.
6/16 in.
Number of handholes/i.d.
6/6 + 2/2 in.
At 2652 MWt a, b At Zero Power b Reactor coolant water volume 1077 ft3 1077 ft3 Primary-side fluid heat content 28.4 x 106 Btu 27.5 x 106 Btu Secondary-side water volume 1688.5 ft3 3581.8 ft3 Secondary-side steam volume 3870 ft3 1976.7 ft3 Secondary-side fluid heat content 45.53 x 106 Btu 95.0 x 106 Btu
- a. 2652 MWt represents the steam generator design performance capability and is not intended to indicate reactor thermal power rating.
- b. The parameter values listed in this section of the table represent initial plant design and operating information. These values are not intended to be updated in the future.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-27 Table 4.1-5 REACTOR COOLANT PUMP DESIGN DATA Number of pumps 3
Design pressure/operating pressure 2485/2235 psig Hydrostatic test pressure 3107 psig Design temperature (casing) 650°F Revolutions per min at nameplate rating 1170 Design head 280 ft Design capacity/pump 88,500 gpm Flow at 542.9°F/pump 33.6 x 106 lb/hr Seal-water injection/pump 8 gpm Seal-water return/pump 2.5 gpm Pump discharge nozzle i.d.
27.5 in.
Pump suction nozzle i.d.
31 in.
Overall pump assembly height 25 ft. 5 in.
Pump casing water volume/pump 56 ft3 Thermal barrier water volume/pump 25 ft3 Approximate pump-motor moment of inertia 70,000 lb/ft2 North Anna Motors Original Surry Motors Motor data Type ac induction single speed, air cooled ac induction single speed, air cooled Voltage 4000V 4000V Insulation class B thermolastic epoxy B thermolastic epoxy Phase 3
3 Frequency 60 Hz 60 Hz Starting Input (hot reactor coolant) 5163 kW 4375 kW Input (cold reactor coolant) 6839 kW 5740 kW Power (nameplate) 7000 hp 6000 hp
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-28 Table 4.1-6 REACTOR COOLANT PIPING DESIGN DATA Design/operating pressure 2485/2235 psig Hydrostatic test pressure (cold) 3107 psig Design temperature (except pressurizer surge line) 650°F Design temperature (pressurizer surge line)b 680°F Reactor inlet piping i.d.
27.5 in.
Reactor inlet piping, nominal thickness 2.375 in.
Reactor outlet piping, i.d.
29 in.
Reactor outlet piping, nominal thickness 2.50 in.
Coolant pump suction piping, i.d.
31 in.
Coolant pump suction piping, nominal thickness 2.625 in.
Pressurizer surge line piping, nominal diametera 12 in.
Pressurizer surge line piping, nominal thickness 1.125 in.
Water volume (all three loops) 1041 ft3
- a. Surge line fitted with a 14 in./12 in. adapter at the pressurizer.
- b. Pressurizer surge line is also evaluated for the effect of thermal stratification and stripping per NRC Bulletin 88-11, dated December 20, 1988 (Appendix 15A, References 37 & 38).
Table 4.1-7 LOOP STOP VALVES Design/normal operating pressure 2485/2235 psig Hydrostatic test pressure shop/loop 5400/3107 psig Design temperature 650°F Hot-leg valve size, nominal 29 in.
Cold-leg valve size, nominal 27.50 in.
Open/close travel time 210 sec
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-29 Table 4.1-8 THERMAL AND LOADING CYCLES Transient Conditions Design Cyclea Heatup at 100°F/hr 200 Cooldown at 100°F/hr 200 Loading at 5% of full power per min (15 to 100% equals one cycle) 18,300 Unloading at 5% of full power per min (100 to 15% equals one cycle) 18,300 Step load increase of 10% full power (but not to exceed full power) 2000 Step load decrease of 10% of full power 2000 Step load reduction from 100 to 50% load 200 Reactor trip from full power 400 Hydrostatic test pressure, 3107 psig at 100°F 5
Hydrostatic test pressure, 2485 psig at 400°F 40 Steady-state fluctuations - the reactor coolant average temperature for purposes of design will be assumed to increase and decrease a maximum of 6°F in 1 minute. The corresponding reactor coolant pressure variation will be less than 100 psig. It is assumed that an infinite number of such fluctuations will occur.
- a. Estimated for equipment design purposes (using the original license period of 40 years as a basis) and not intended to be an accurate representation of actual transients, or to reflect actual operating experience. These estimates have been retained for the 60-year renewed operating license period.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-30 Table 4.1-9 REACTOR COOLANT SYSTEM - CODE REQUIREMENTS Component Codes Reactor vessel a ASME IIIbClass A Control rod drive mechanism housing ASME IIIb Class A Unit 1 control rod drive mechanism head adapter plugs ASME IIIb Class 1 Steam generators Tube side ASME IIIb Class A Shell sidec ASME IIIb Class C Reactor coolant pump casing No code (design per ASME III - Article 4)
Pressurizer ASME IIIb Class A Pressurizer relief tank ASME IIIb Class C Pressurizer safety valves ASME IIIb Reactor coolant piping USAS B31.1d System valves, fittings, and piping USAS B31.1d,e
- a. Unit 1 Reactor Vessel Closure Head replaced with closure head designed to French Construction Code (R-CCM) 1993 Edition with 1st Addenda June 1994, 2nd Addenda June 1995, 3rd Addenda June 1996, and Modification Sheets FM 797, 798, 801, 803, 804, 805, 806, and 807. The sizing calculations and the stress and fatigue analysis were performed to ASME B&PV Code,Section III, 1995 Edition 1996 Addenda. The Design Report certified that the Unit 1 closure head meets the design requirements and stress limits for the ASME B&PV Code,Section III, 1968 Edition through Winter 1968 Addenda
- b. ASME Boiler and Pressure Vessel Code,Section III, Nuclear Vessels.
- c. The shell side of the steam generator conforms to the requirements for Class A vessels and is so stamped as permitted under the rules of Section III.
- d. USAS B31.1 Code for Pressure Piping.
- e. A reanalysis of the pressurizer surge line to account for the effect of thermal stratification and striping was performed in accordance with the requirements of ASME Boiler and Pressure Vessel Code,Section III 1986 with addenda thru 1987 incorporating high cycle fatigue as required by NRC Bulletin 88-11, dated December 20, 1988.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-31 Table 4.1-10 CAPSULE SPECIMEN DATA, UNIT 1 Number of Specimens Charpy Tensile WOL Material - Type I Capsules (S, U, W, and Y)
Plate #1 (high NDT) 10 2
3 Plate #2 10 2
3 Correlation monitor 8
Material - Type II Capsules (T, V, X, and Z)
Plate #2 8
2 2
Weld metal 8
2 2
Heat-affected-zone metal 8
Correlation monitor 8
Dosimeters Pure Cu Pure Fe Pure Ni CoAl (0.15% Co)
CoA1 (cadmium shielded)
U238 (Type II capsules only)
Np237 (Type II capsules only Thermal Monitors 97.5% Pb, 2.5% Ag (579°F melting point) 97.5% Pb, 1.75% Ag, 0.75% Sn (590°F melting point)
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-32 Table 4.1-11 CAPSULE SPECIMEN DATA, UNIT 2 Number of Specimens Charpy Tensile WOL Material - Capsules X, W, V, and S Plate #1 (Longitudinal Orientation) 10 Plate #1 (Transverse Orientation) 10 2
4 Weld metal 8
2 Heat-affected-zone metal 8
Correlation monitor 8
Material - Capsules T and U Plate #1 (Longitudinal Orientation) 10 2
4 Plate #1 (Transverse Orientation) 10 Weld metal 8
2 Heat-affected-zone metal 8
Correlation monitor 8
Material - Capsules Y and Z Plate #1 (Longitudinal Orientation) 10 2
Plate #1 (Transverse Orientation) 10 Weld metal 8
2 4
Heat-affected-zone metal 8
Correlation monitor 8
Dosimeters - Capsules S, T, U, V, W, X, Y, Z Pure Cu Pure Fe Pure Ni CoAl (0.15% Co)
CoA1 (cadmium shielded)
U238 NP237 Thermal Monitors - Capsules S, T, U, V, W, X, Y, Z 97.5% Pb, 2.5% Ag (579°F melting point) 97.5% Pb, 1.75% Ag, 0.75% Sn (590°F melting point)
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-33 Table 4.1-12 SURVEILLANCE CAPSULE WITHDRAWAL SCHEDULEa FOR SURRY UNIT 1 Capsule Identification Capsule Location Estimated Withdrawal EFPY/Year Insert EFPY/Year Estimated Capsule Fluence (x 1019)b Tc 285° 1.1/1974 NA 0.281 Wc 55° 3.5/1978 NA 0.431 Vc 165° 8.2/1986 NA 1.94 X
65° 13.3/1994 NA 1.28 X
165° NA 13.3/1994 NA Xc 165° 16.3/1997 NA 1.60 Z
245° 13.3/1994 NA 2.11 Z
285° NA 13.3/1994 NA Zc 285° 44.0/2027 NA 6.35 U
45° 13.3/1994 NA 0.95 U
65° NA 13.3/1994 NA Ud 65° NA NA 4.59 (48.0 EFPY) 6.82 (68.0 EFPY)
Sd 295° NA NA 5.42(48.0 EFPY) 7.65 (68.0 EFPY)
Y 305° 15.8/1997 NA 1.52 Y
165° NA 15.8/1997 NA Yd 165° NA NA 6.24 (48.0 EFPY) 7.82 (58.0 EFPY)
- a. Withdrawal schedule meets requirements of ASTM E 185-82, Standard Practice for Conducting Surveillance Tests for Light - Water Cooled Nuclear Power Reactor Vessels, dated July 1, 1982.
- b. 48. 0 EFPY corresponds to the estimated cumulative core burnup at the end of the 60 - year license period. Fluence values for withdrawn capsules are obtained from capsule test reports.
- c. These capsules are required to satisfy the requirements of ASTM E 185-82 during the license period.
- d. Standby Capsules S, U, and Y are available to satisfy potential f1uence monitoring requirements during the 20 - year license renewal period. Future projected capsule fluence values are related to asset management objectives.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-34 Table 4.1-13 SURVEILLANCE CAPSULE WITHDRAWAL SCHEDULEa FOR SURRY UNIT 2 Capsule Identification Capsule Location Estimated Withdrawal EFPY/Year Insert EFPY/Year Estimated Capsule Fluence (x 1019)b Xc 285° 1.2/1975 NA 0.297 Wc 245° 3.8/1979 NA 0.636 Vc 165° 8.7/1986 NA 1.89 Y
295° 14.3/1995 NA 1.97 Y
165° NA 14.3/1995 NA Yc 165° 20.8/2002 NA 2.73 U
65° 27.9/2009 NA 3.49 U
285° NA 27.9/2009 NA Uc 285° 49.0/2032 NA 7.26 T
55° 19.7/2002 NA 1.82 T
165° NA 19.7/2002 NA Td 165° NA NA 6.65 (48.0 EFPY) 9.06 (60.0 EFPY)
Z 305° 13.7/1994 NA 1.34 Z
245° NA 13.7/1994 NA Zd 245° NA NA 5.39 (48.0 EFPY) 8.21 (68.0 EFPY)
S 45° 15.0/1996 NA 1.07 W1 285° NA 10.9/1991 NA W1e 285° 16.4/1997 NA 0.690
- a. Withdrawal schedule meets requirements of ASTM E 185-82, Standard Practice for Conducting Surveillance Tests for Light - Water Cooled Nuclear Power Reactor Vessels, dated July 1, 1982.
- b. 48. 0 EFPY corresponds to the estimated cumulative core burnup at the end of the 60 - year license period. Fluence values for withdrawn capsules are obtained from capsule test reports.
- c. These capsules are required to satisfy the requirements of ASTM E 185-82 during the license period.
- d. Standby Capsules T and Z are available to satisfy potential f1uence monitoring requirements during the 20 - year license renewal period. Future projected capsule fluence values are related to asset management objectives.
- e. Master Integrated Reactor Vessel Materials Surveillance Program capsule.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-35 Table 4.1-14 UNIT 1 REACTOR PRESSURE VESSEL TOUGHNESS DATA (UNIRRADIATED)d Material Heat or Code No Material Spec. No.
Cu (%)
Ni (%)
TNDT (°F)
(°F)
NMWDb Upper Shelf Energy (ft-lb)
Closure head dome 7096 SA-533B Cl. 1 16MND5 (M2122)
.08
.66
-49
-49 Head flange E4381-E4382 SA-508 Gr. 3 Cl. 1 16MND5 (M2113)
.06
.73
-67
-67 180c Vessel flange ZV-3339 A508 Cl. 2
.10
.65
-114.6f
-114.6f
>83 Inlet nozzle 9-5078 A508 Cl. 2
.159g
.87 3.4f 11.6f 64 Inlet nozzle 9-4819 A508 Cl. 2
.159g
.84
-47.2f
-47.2f 68 Inlet nozzle 9-4787 A508 Cl. 2
.159g
.85 3.1f 10.3f 63 Outlet nozzle 9-4762 A508 Cl. 2
.159g
.83
-92.0f
-87.5f 82 Outlet nozzle 9-4788 A508 Cl. 2
.159g
.84
-54.2f
-50.2f 71 Outlet nozzle 9-4825-1 A508 Cl. 2
.159g
.85 47.2f
-44.9f 68 Upper shell 122V109VA1 A508 Cl. 2
.11
.74 40 40 114c Intermediate shell C4326-1 A533B Cl. 1
.11
.55 10 10 115c Intermediate shell C4326-2 A533B Cl. 1
.11
.55 0
11.4a 94 Lower shell C4415-1 A533B Cl. 1
.102
.493 20 20 103c Lower shell C4415-2 A533B Cl. 1
.11
.50 0
04.6a 82 Bottom head ring 123T338VA1 A508 Cl. 2 185h
.69 50 50a 96 Bottom dome C4315-3 A533B Cl. 1
.14
.59 0
0 85
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-36 Table 4.1-14 (continued)
UNIT 1 REACTOR PRESSURE VESSEL TOUGHNESS DATA (UNIRRADIATED)d Material Heat or Code No Material Spec. No.
Cu (%)
Ni (%)
TNDT (°F)
(°F)
NMWDb Upper Shelf Energy (ft-lb)
Inter. Shell Vertical Weld Seam (L3, L4) & Lower Shell Vertical Weld Seam (L1) 8T1554 & Linde 80 flux Lot 8579
.16
.57 0a
-48.6 64/EMAe Lower shell vertical weld seam, L2 299L44 & Linde 80 flux Lot 8596
.34
.68 0a
-74.3 64/EMAe Inter. to lower shell girth seam 72445 & Linde 80 flux Lot 8597 and 8632
.22
.54 0a
-72.5 64/EMAe Upper shell to Inter. shell girth seam & lower shell to bottom head ring girth seam (OD) 25017 & SAF 89 flux Lot 1197
.33
.10 0a 0a 64/EMAe Inlet nozzle to upper shell weld seamsi 299L44 & Linde 80 flux, Lot 8596 8T1762 & Linde 80 flux, Lot 8596
.34i
.19i 0.68i 0.57i
-7.0i
-4.9i 64i 64i Outlet nozzle to upper shell weld seamsi 8T1762 & Linde 80 flux, Lot 8578 8T1554B & Linde 80 flux, Lot 8579
.19i
.16i 0.57i 0.57i
-4.9i
-4.9i 64i 64i Lower shell to bottom head ring girth weld (Root ID) 721858 & SAF 89 flux, Lot 1197
.08 1.0j 10a 78k NOTES:
- a. Estimated per NRC standard review plan, NUREG-0800, Section BTP 5-3.
- b. Normal to major working direction - estimated per NRC standard review plan, NUREG-0800, Section BTP 5-3 for base metal material.
- c. Actual values based on tests performed normal to the major working direction.
- d. Reactor Vessel Fabricator Certified Test Reports
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-37
- e. The equivalent margins analysis in Reports BAW-2494, Revision 1; BAW-2178NP, Supplement 1; and BAW-2192NP, Supplement 1, demonstrate compliance with the requirements of 10 CFR 50, Appendix G.
- f. Determined per BWRVIP-173-A, Appendix B Alternative Approach 2.
- g. Generic value for nozzle forging based on mean plus two sigma approach and the data in Westinghouse nozzle database.
- h. Generic value for A508, Class 2 shell forging based on mean plus two sigma approach and the data in ORNL/TM-2006/530 Table G.2.
- i. Determined per BAW-2313, Revision 7, Supplement 1. The initial USE values for the Linde 80 welds are set to the generic value of 64 ft-lbs per BAW-2313, Revision 7, Supplement 1, Revision 1. Only limited Charpy test information is available for Heat #25017. Based on the average Charpy energy valve of the weld qualification tests completed at 10°F, the USE for Heat #25017 is at least 64 ft-lbs.
- j. Generic value per 10 CFR 50.61.
- k. Determined from surveillance capsule results from a sister plant.
Table 4.1-14 (continued) (CONTINUED)
UNIT 1 REACTOR PRESSURE VESSEL TOUGHNESS DATA (UNIRRADIATED)d Material Heat or Code No Material Spec. No.
Cu (%)
Ni (%)
TNDT (°F)
(°F)
NMWDb Upper Shelf Energy (ft-lb)
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-38 Table 4.1-15 UNIT 2 REACTOR PRESSURE VESSEL TOUGHNESS DATA (UNIRRADIATED)
Material Heat or Code No Material Spec. No.
Cu (%)
Ni (%)
TNDT (°F)
(°F)
NMWDb Upper Shelf Energy (ft-lb)
Closure head 02W1-1-1-1 SA508 Gr.3 Cl. 2
<.13
.37-1.03
-60
-60 191c Vessel flange ZV-3476 A508 Cl. 2
.10
.64
-156.3e
-156.3e 128 Inlet nozzle 9-4815 A508 Cl. 2
.159f
.87
-7.5e 4.5e 66 Inlet nozzle 9-5104 A508 Cl. 2
.159f
.84
-36.7e
-29.7e 73 Inlet nozzle 9-5205 A508 Cl. 2
.159f
.86 6.5e 6.5e 67 Outlet nozzle 9-4825 A508 Cl. 2
.159f
.85
-58.1e
-58.1e 73 Outlet nozzle 9-5086 A508 Cl. 2
.159f
.86
-26.6e
-26.6e 77 Outlet nozzle 9-5086 A508 Cl. 2
.159f
.87
-33.8e
-33.8e 71 Upper shell 123V303 A508 Cl. 2
.11
.72 30 30a 104 Intermediate shell C4331-2 A533B Cl. 1
.12
.60
-10 15.0a 84 Intermediate shell C4339-2 A533B Cl. 1
.11
.54
-20 7.8a 83 Lower shell C4208-2 A533B Cl. 1
.15
.55
-30
-30a 94 Lower shell C4339-1 A533B Cl. 1
.107
.53
-10
-4.4a 101c Bottom head ring 123T321 A508 Cl. 2
.185g
.71 10 10a 101 Bottom dome C4361-3 A533B Cl. 1
.15
.52
-20
-20 80
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-39 Inter. shell vertical weld seam L3 (100%), L4 (OD50%)
72445 & Linde 80 flux Lot8579
.22
.54
-72.5 64h/EMAd Inter. & lower shell vertical welds Seam L1 (100%)
8T1762 & Linde 80 flux 8597
.19
.57
-48.6 64h/EMAd Seam L2 (ID63%)
8T1762 & Linde 80 flux 8597
.19
.57
-48.6 64h/EMAd Seam L2 (OD37%)
8T1762 & Linde 80 flux 8632
.19
.57
-48.6 64h/EMAd Seam L4 (ID50%)
8T1762 & Linde 80 flux 8597
.19
.57
-48.6 64h/EMAd Inter. to lower shell girth seam & lower shell to bottom head ring girth weld 0227 and Grau Lo Flux Lot LW320
.187
.545 0a 82/EMAd Upper shell to Inter.
shell girth seam 4275 & SAF 89 flux Lot 02275
.35
.10 0a 68h/EMAd Inlet nozzle to upper shell weld seamsg 8T1762 & Linde 80 flux Lots 8597 and 8632)
.19h
.57h
-4.9h 64h Outlet nozzle to upper shell weld seamsh Rotterdam Weld
.35i 1.0i 30i 71i Table 4.1-15 (continued)
UNIT 2 REACTOR PRESSURE VESSEL TOUGHNESS DATA (UNIRRADIATED)
Material Heat or Code No Material Spec. No.
Cu (%)
Ni (%)
TNDT (°F)
(°F)
NMWDb Upper Shelf Energy (ft-lb)
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-40 NOTES:
- a. Estimated per NRC standard review plan, NUREG-0800, Section MTEB 5-2
- b. Normal to major working direction - estimated per NRC standard review plan, NUREG-0800, Section BTP 5-3 for base metal material.
- c. Actual values based on test performed normal to the major working direction
- d. The equivalent margins analysis in Reports BAW-2494, Revision 1; BAW-2178NP, Supplement 1; and BAW-2192NP, Supplement 1, demonstrate compliance with the requirements of 10 CFR 50, Appendix G.
- e. Determined per BWRVIP-173-A, Appendix B Alternative Approach 2.
- f. Generic value for nozzle forging mean plus two sigma approach and the data in Westinghouse nozzle database.
- g. Generic value for A508, Class 2 shell forging based on mean plus two sigma approach and the data in ORNL/TM-2006/530 Table G.2.
- h. Determined per BAW-2313, Revision 7, Supplement 1. The initial USE values for the Linde 80 welds are set to the generic value of 64 ft-lbs per BAW-2313, Revision 7, Supplement 1, Revision 1. Only limited Charpy test information is available for Heat #4275. Based on the average Charpy energy value of the weld qualification tests completed at 10°F, the USE for Heat#4275 is at least 68 ft-lbs.
- i. No data available. The chemistry values of this weld were taken to be generic values per Regulatory guide 1.99, Revision 2. The initial RTNDT value was determined using ASME III minimum requirements at the time of fabrication and NUREG-0800, Section BTP 5-3, Position 1.1(4). The value was determined using ASME III minimum requirements at the time of fabrication and NUREG-0800, Section BTP 5-3, Position 1.2 Table 4.1-15 (continued)
UNIT 2 REACTOR PRESSURE VESSEL TOUGHNESS DATA (UNIRRADIATED)
Material Heat or Code No Material Spec. No.
Cu (%)
Ni (%)
TNDT (°F)
(°F)
NMWDb Upper Shelf Energy (ft-lb)
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-41 Figure 4.1-1 TYPICAL SURVEILLANCE CAPSULE, ELEVATION VIEW
Revision 52Updated Online 09/30/20 SPS UFSAR 4.1-42 Figure 4.1-2 INSTALLED SURVEILLANCE CAPSULE, PLAN VIEW
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-1 4.2 SYSTEM DESIGN AND OPERATION 4.2.1 General Description The reactor coolant system consists of three similar heat transfer loops connected in parallel to the reactor vessel. Each loop contains a steam generator, a pump, two loop-stop valves, loop piping, and instrumentation. The pressurizer surge line is connected to one of the loops on the reactor side of a stop valve. Auxiliary system piping connections into the reactor coolant piping are provided as necessary. A flow diagram of the system is shown in Figure 4.2-1 and Reference Drawings 1 and 2. All of the major components of the reactor coolant system are located inside containment.
Reactor coolant system and component design data are listed in Tables 4.1-1 through 4.1-7.
Pressure in the system is controlled by the pressurizer, where water and steam pressure are maintained through the use of sprays and electrical heaters. Steam can be formed by the heaters or condensed by pressurizer spray to minimize pressure variations due to contraction and expansion of the coolant. Instrumentation to be used in the pressure control system is described in Chapter 7.
Spring-loaded code safety valves and power-operated relief valves are connected to the pressurizer and discharge to the pressurizer relief tank, where the discharged steam is condensed and cooled by mixing with water. To ensure degassification and decay heat removal under certain accident conditions without relying on main coolant pump operation the reactor coolant vent system provides remote venting capability of the reactor vessel head and pressurizer steam space.
4.2.2 Components 4.2.2.1 Reactor Vessel The reactor vessel is a cylinder with a hemispherical bottom and a flanged and gasketed removable upper head. Figure 4.2-2 is a schematic of the reactor vessel. The materials of construction of the reactor vessel are given in Table 4.2-1. Provision is made for removal of reactor internals if required during reactor life.
Coolant enters the reactor vessel through inlet nozzles in a plane just below the vessel flange and above the core. The coolant flows downward through the annular space between the vessel wall and the core barrel into a plenum at the bottom of the vessel, where it reverses direction. Approximately 95% of the total coolant flow is effective for heat removal from the core. The remainder of the flow includes the flow through the control rod assembly guide thimbles, the leakage across the fuel assembly outlet nozzles, and the flow deflected into the head of the vessel for cooling the upper flange. All the coolant is united and mixed in the upper plenum, and the mixed coolant stream then flows out of the vessel through exit nozzles located on the same plane as the inlet nozzles.
The reactor vessel contains the core support assembly, upper plenum assembly, fuel assemblies, control rod assemblies, surveillance specimens, and incore instrumentation. The
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-2 reactor vessel internals are designed to direct the coolant flow, support the reactor core, and guide the control rod assemblies in the withdrawn position.
The reactor internals are described in detail in Section 3.5, and the general arrangement of the reactor vessel and internals is shown in Figure 3.5-2. Design data are listed in Table 4.1-2.
A one-piece thermal shield, concentric with the reactor core, is located between the core barrel and the reactor vessel. The thermal shield is bolted and welded to the top of the lower core barrel. The thermal shield, which is cooled by the coolant on its downward pass, protects the vessel by attenuating much of the gamma radiation and some of the fast neutrons that escape from the core. This reduces thermal stresses in the vessel that result from heat generated by the absorption of gamma energy. The thermal shield is illustrated in Figure 3.5-6 and described in Section 3.5.1.1.
Fifty incore instrumentation nozzles are located on the lower head. The reactor vessel closure head and the reactor vessel flange are joined by 58 6-inch-diameter studs. Two concentric metallic o-rings seal the reactor vessel when the reactor closure head is bolted in place. A leakoff connection is provided between the two o-rings to monitor leakage across the inner o-ring. In addition, a leakoff connection is also provided beyond the outer o-ring seal.
The reactor vessel insulation is of the reflective type, supported from the nozzles, and consisting of inner and outer sheets of stainless steel spaced 3 inches apart with multilayer aluminum foil as the insulating agent. The clearance between the reactor vessel and insulation is 0.5 inch. Insulation sheets are also provided for the reactor closure head and are supported on the refueling seal ledge and vent shroud support rings.
For Unit 1, to reduce radiation exposure to personnel during reactor vessel head removal and during maintenance operations in the vicinity of the head a permanent reactor vessel head shield has been installed. This shielding consists primarily of cylindrical steel plate (ASTM A36) that is permanently attached to the intermediate lift ring. The shielding is comprised of three sections, each spanning 120 inches. Each section is approximately one inch thick, six feet tall and weighs 3500 pounds. To allow ease of maintenance activities a cutout is provided in the shield for access to the Reactor Vessel Level Indication System. Cutouts are also provided for cooling shroud ventilation nozzles, which are covered by swing doors.
For Unit 2, to reduce exposure to personnel during reactor vessel head removal and during maintenance operations in the vicinity of the head a permanent reactor vessel head shield has been incorporated as an integral part of the CRDM cooling shroud. The shield consists of upper and lower sections. The lower section consists primarily of cylindrical stainless steel plate that is permanently attached to the reactor vessel head lifting rig lugs by special mounting devices. The lower shield/cooling shroud is comprised of four curved segments bolted together to encircle the RV head. These segments are constructed of 3/8 inch ASTM A240, TP304 stainless steel plate that is 40 inches high welded to the inside of one inch ASTM A240, TP304 stainless steel that is 43 inches high and weighs approximately 4500 lb. Three of the segments each have an opening
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-3 through which air is drawn from the containment as part of the CRDM cooling system. There are holes in two of the segments, such that the RV head vent line passes through one without contacting the shield/shroud and the RVLIS line passes through the other one without contacting the shield/shroud. To accomplish the radiation shielding function, a sliding door is provided to cover each opening when work is being performed in the head area. The doors slide on wheels on a rail mounted above each opening. Door restraints are mounted on the lower shield/shroud to keep the door from moving radially away from the lower shield/shroud. The upper shield/cooling shroud is square in design. The upper shield/cooling shroud consists of four flat side panels and four corner panels. The side and corner panels are constructed of one inch ASTM A240, TP304 stainless steel that is approximately 50 inches high and weighs approximately 7000 lb.
The head lifting rig is classified as QA Category II and since the addition of the shielding to the reactor vessel head does not modify or change the operation, function, or design of the Reactor Coolant System (RCS) or any of its components, this design change is classified as QA Category II. The head shielding is seismically designed in order to protect safety-related equipment in the area following a postulated seismic event.
Protective coating of the Unit 1 shielding was performed in accordance with ANSI N101.4, Quality Assurance for Protective Coatings Applied to Nuclear Facilities, prior to receipt on site.
All material installed by this design is environmentally qualified for pressure, temperature, relative humidity, and radiation conditions inside the containment during normal operation and following accident conditions. There are no protective coatings on the Unit 2 shielding.
Manufacture of the original Surry vessels was begun by the Babcock & Wilcox Company at Mt. Vernon, Indiana. However, due to scheduling problems, it was necessary to transfer these vessels in a partially fabricated state to the Rotterdam Dockyard Company, Rotterdam, The Netherlands, for completion of fabrication.
The basic construction of the Surry vessels consists of the following:
- 1. Vessel assembly
- a. Vessel flange - Machined forging.
- b. Nozzle shell - Machined forging, penetrated by six primary coolant nozzles.
- c. Intermediate and lower shells - Each fabricated from two formed cylindrical plates. Two longitudinal weld seams.
- d. Lower head transition ring - Machined forging.
- e. Lower head - Formed from single plate, penetrated by 50 instrumentation tubes.
- 2. Closure head assembly Unit 1 Dome section - Hemispherical dished segment plate (one piece), penetrated by 65 control rod drive mechanism housings.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-4 Unit 2 closure head assembly is a single forging (one piece), penetrated by 71 total penetrations as follows:
- a. 48 penetrations for Control Rod Drive Mechanism (CRDM) head adapters with threaded
- housings,
- b. 17 penetrations for spare CRDM head adapters with threaded capped housings,
- c. 4 penetrations with cap,
- d. 1 penetration for reactor vessel head venting,
- e. 1 penetration for Reactor Vessel Level Indication System (RVLIS).
The replacement RVCH was originally intended for NAPS Unit 2. Some fabrication was performed before it was redesigned for Surry Unit 2. Therefore there are 4 penetrations with cap on the Surry Unit 2 head.
Inside surfaces of both closure head and vessel assembly that contact primary coolant are clad with corrosion-resistant material.
At the time of their transfer from Babcock & Wilcox to Rotterdam, the original vessels were at the following stages of completion:
- 1. Surry Unit 1
- a. Closure head Original closure head has been replaced with a closure head fabricated by Framatome ANP for a French utility power plant and purchased by Dominion for Surry Unit 1.
- b. Vessel Flange welded to nozzle shell, six nozzles welded in nozzle shell, inside surfaces clad.
Intermediate shell welded to lower shell, not clad.
Lower head dome welded to transition ring, inside surfaces clad.
- 2. Surry Unit 2
- a. Closure head The replacement Unit 2 closure head was fabricated by Mitsubishi Heavy Industries, LTD at the Kobi Shipyard and Machinery Work, Japan.
- b. Vessel Flange welded to nozzle shell, three of six primary nozzles welded.
Intermediate and lower shells formed and welded but not welded together, no clad.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-5 Lower head dome welded to transition ring, not clad.
Four solenoid operated globe valves initiate and terminate venting in two redundant flow paths at each vent location. These isolation valves are powered by vital dc power supplies and are fail-closed active valves. A 3/8-inch orifice is installed in each flow path to minimize the reactor coolant pressure boundary extension and to maintain the venting rate at an acceptable value.
System operation is conducted from the control room of each unit.
4.2.2.2 Pressurizer The general arrangement of the pressurizer is shown in Figure 4.2-4, and the design data are listed in Table 4.1-3.
The pressurizer maintains the required reactor coolant pressure during steady-state operation, limits the pressure changes caused by coolant thermal expansion and contraction during normal load transients, and prevents the pressure in the reactor coolant system from exceeding the design pressure.
The pressurizer contains replaceable direct immersion heaters, safety and relief valves, a spray nozzle, a vent system, and interconnecting piping, valves, and instrumentation. The electric heaters are located in the lower section of the vessel, and maintain the pressure of the reactor coolant system by keeping the water and steam in the pressurizer at system saturation temperature. Table 4.1-3 indicates initial design capacity for pressurizer heaters. The initial heater design capacity allows for operation with some heaters out of service. With all heaters in service, the heaters are capable of raising the temperature of the pressurizer and contents at approximately 55°F/hr during reactor start-up. Acceptable operation has been evaluated with 1200 kW of heater capacity, which would be capable of raising the temperature of the pressurizer and contents at approximately 52°F/hr during reactor start-up.
The pressurizer is designed to accommodate positive and negative surges caused by load transients. The surge line attached to the bottom of the pressurizer connects the pressurizer to the hot leg of a reactor coolant loop. During a positive surge, caused by a decrease in load, the spray system, which is fed from the cold leg of a coolant loop, condenses steam in the vessel to prevent the pressurizer pressure from reaching the operating point of the power-operated relief valves.
Power-operated spray valves on the pressurizer limit the pressure during load transients. In addition, the spray valves can be operated remote manually from the control room. A small continuous spray flow is provided to ensure that the pressurizer liquid is homogeneous with the coolant and to prevent excess cooling of the spray and surge line piping.
During a negative pressure surge, caused by an increase in load, flashing of water to steam and generation of steam by automatic actuation of the heaters keep the pressure above the minimum allowable limit. Heaters are also energized on high water level during positive surges to heat the subcooled surge water entering the pressurizer from the reactor coolant loop.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-6 A Westinghouse Owners Group analysis has determined that the minimum requirement to maintain natural circulation in a three-loop plant with a pressurizer volume of 1300 ft3 is 125 kW of heater capacity. Two backup heater groups rated at 250 and 200 kW and their associated controls are energized from redundant emergency buses H and J, which are capable of being fed from either offsite power or emergency power. The Class 1E interfaces for motive and control power are protected by safety grade circuit breakers.
The pressurizer heaters are not automatically shed from the emergency power sources upon the occurrence of a safety injection actuation signal. The pressurizer heaters will, however, be automatically shed from the Emergency Bus with a Loss of Offsite Power (LOOP). Once the Emergency Bus has been reenergized, the pressurizer heaters are sequenced onto the bus after a 180-second time delay. Refer to Section 8.5 for a more detailed description of the Emergency Power System. Procedures have been implemented to instruct the operator in the use of pressurizer heaters in establishing and maintaining natural circulation. This is the preferred method of controlling the RCS pressure during a cooldown.
The pressurizer is constructed of carbon steel, with internal surfaces clad with austenitic stainless steel. The heaters are sheathed in austenitic stainless steel.
The pressurizer vessel surge nozzle is protected from thermal shock by a thermal sleeve. A thermal sleeve also protects the pressurizer spray nozzle connection. A manway is provided in the top portion of the pressurizer.
The pressurizer vent system is provided to remove non-condensable gasses from the pressurizer steam space. The pressurizer vent is designed and operated like the reactor head vent system discussed in Section 4.2.2.1. The pressurizer vent system does not provide a means of pressure control.
4.2.2.3 Steam Generators A steam generator repair program was completed at the Surry Power Station in 1980 and 1981 for Units 2 and 1, respectively. The purpose of the program was to repair degradation caused by corrosion-related phenomena and to restore the integrity of the steam generators to a level equivalent to new equipment. The repair program basically consisted of replacing the steam generator lower assembly and refurbishing the upper assembly. This program is described in Reference 1. The following description pertains to the as-modified system. Principal design data are given in Table 4.1-4; a general sectional view is given in Figure 10.3-2.
4.2.2.3.1 General System Description Each loop of the reactor coolant system contains a vertically mounted U-tube steam generator. These generators consist of two integral sections: an evaporator section and a steam drum section. The evaporator section consists of a U-tube heat exchanger, while the steam drum section houses moisture-separating equipment. The steam drum section is located in the upper part of the steam generator. The lower assembly of each steam generator is designed and
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-7 manufactured in accordance with Sections III and XI of the 1974 edition of the ASME Boiler and Pressure Vessel Code, including addenda through Winter 1976. The steam generator lower assemblies bear the applicable ASME Code stamp. The original upper shell was reanalyzed based on the above referenced version of the Code (excluding the Appendix G fracture mechanics analysis).
High pressure and high temperature reactor coolant flows into the channel head, through the Inconel U-tubes, and back to the channel head. A partition plate divides the channel head into inlet and outlet sections. An access opening for inspection and maintenance is provided in each section of the channel head. Welding of the U-tubes to the tube support plate ensures zero leakage across the tube joints. The tubes are supported at intervals by horizontal support plates.
4.2.2.3.2 Steam Generator Design Features The current steam generators include many design improvements over the original steam generators. These features improve the flow distribution, improve bundle access, reduce secondary-side corrosion, facilitate maintenance and inservice inspection activities, and ultimately ensure the integrity of the steam generators. The replacement lower assembly includes the following features:
- 1. A cast channel head is used to meet current inservice inspection (ISI) requirements.
Improvements incorporated affect the tube-to-tubesheet weld and the ends of the primary nozzles.
- 2. Primary nozzle closure rings are welded inside the channel head at the base of each primary nozzle so that closure plates can be installed during primary chamber maintenance. This design allows the plates to be bolted to the rings for quick installation and removal. Closure plates allow maintenance or inspection to be conducted in the channel head while other operations are conducted with the reactor cavity flooded.
- 3. The steam generators were originally equipped with a channel head drain that allowed the steam generator to be completely drained before performing inspection and maintenance activities. The channel head drains have since been removed and capped due to transgrannular stress corrosion cracking.
- 4. Recessed tube-to-tubesheet welds were used in conjunction with full-depth tube roll for all tubes (see Figure 4.2-5). Absence of the protruding tube stub in the present design results in lower entry losses and therefore a lower pressure drop in the primary loop. In addition, a possible point of crud buildup is avoided with this design.
- 5. The primary manways and all handholes are designed to receive either welded diaphragms, gaskets, or both, without any modifications. In addition, bolt-on trunnions are provided for two handholes to facilitate installation.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-8
- 6. All pressure-containing parts, with the exception of the Inconel tubes, are made of carbon or low-alloy steel. All surfaces in contact with the reactor coolant are made of, or clad with, stainless steel or Inconel.
- 7. The locations of each tube are marked in accordance with an established grid system, i.e.,
row and column number. The marking of the tubes facilitates identification of tubes for plugging or inspection, thereby minimizing radiation exposure and time required for the activity.
- 8. The insulation for the steam generators and associated piping is reflective type, stainless steel jacket, fabricated in removable sections where access to welds is required for inservice inspection.
Reflective insulation was chosen for the following reasons:
- a. Chloride and fluoride free.
- b. Quickly removed and replaced for inservice inspection.
- c. All metal, will not absorb water.
- d. Easy to decontaminate.
Areas covered with this insulation are as follows:
- a. Steam generators - the entire steam generator.
- b. Reactor coolant piping - reactor coolant piping in each loop from just beyond the hot-leg loop stop valve to the steam generator, and from the bottom of the loop at the pipe restraint on the cold leg to the steam generator.
- c. Main steam piping - from just beyond the crane wall penetration back to the steam generator.
- d. Feedwater piping - from just beyond the crane wall penetration back to the steam generator.
The insulation was cleaned, tested, and/or inspected, and protected against contamination prior to shipping to the site. During installation, handling was performed in a manner that prevented contamination by chlorides, halogens, and other contaminants as described in the specification for steam generator insulation. All surfaces over which the insulation was placed were cleaned and decontaminated of corrosion-forming residues. Cleaning of stainless steel piping met the criteria described in Regulatory Guides 1.37 and 1.44.
- 9. Each steam generator was constructed with 3342 Inconel-600 thermally treated tubes. The tube dimensions are 7/8-inch o.d. with 0.05-inch wall thickness.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-9 Extensive research has determined that significant improvement in the stress corrosion resistance of Inconel-600 tubing can be achieved by modification of the metallurgical structure through thermal treatment. The primary objective of this treatment is to develop an improved metallurgical structure, associated with the grain boundary precipitate morphology, which provides increased margin with respect to stress corrosion performance.
Several benefits result from this treatment: improved resistance to stress corrosion cracking in NaOH, resistance to intergranular attack in oxygenated environments and in sulfur-containing species, and reduction of residual stress imparted by tube processing.
Certain heat treatments can improve caustic stress corrosion resistance but result in a chromium-depleted grain boundary layer (sensitization) that is not as resistant to off-chemistry environments, should they be experienced. Analysis of available data indicates that there is a broad band of temperature and time within the typical sensitization range for Inconel-600 which provides improved resistance to stress corrosion cracking in both caustic and pure water environments. The thermal treatment used was within this time-temperature band.
The thermal treatment was designed to improve the corrosion resistance against secondary-side attack, specifically caustic stress corrosion. The treatment also results in resistance to primary-side stress corrosion cracking. The thermal treatment was performed as a final operation on the straight-length tubing, after the straightening and polishing. It consisted of heat-treating the tubing in a vacuum at a nominal temperature of 1300°F for about 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br />. This treatment results in a microstructure consisting of semi-continuous grain boundary precipitates, but with little or no chromium depletion adjacent to the boundaries. In addition, the eight inner rows (smallest diameter) of tubes were stress-relieved following bending at a temperature of about 1300°F for several hours. This microstructure change in conjunction with the relief of most residual stresses provides the corrosion resistance to both primary-side and secondary-side environments.
Intergranular attack in environments containing oxygen and/or sulfur has been evaluated.
The special thermal heat treatment was established to ensure that the grain boundary morphology is not conducive to intergranular attack. It is known that grain boundary carbide precipitation, while beneficial in caustic and other species, may be detrimental in certain oxygenated and sulfur-bearing environments if the material is sensitized, i.e., there is a chromium-depleted region adjacent to the boundaries. The time and temperature of the special heat treatment have been established to ensure that the microstructure is desensitized toward intergranular attack in environments containing oxygen and sulfur.
Test results obtained during the development of the special heat-treating process validated the above. Desensitization of the material was routinely monitored during production.
4.2.2.4 Reactor Coolant Pumps Each reactor coolant loop contains a vertical single stage centrifugal pump using a controlled leakage seal assembly. A view of a controlled leakage pump is shown in Figure 4.2-6.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-10 The principal design parameters for the pumps are listed in Table 4.1-5. The reactor coolant pump estimated performance and NPSH characteristics are shown in Figure 4.2-7. The performance characteristic is common to all of the higher specific speed centrifugal pumps, and the knee at about 45% design flow introduces no operational restrictions since the pumps operate at full speed.
Reactor coolant is pumped by the impeller attached to the bottom of the rotor shaft. The coolant is drawn up through the impeller, discharged through the passages in the diffuser, and out through a discharge nozzle in the side of the casing. The motor-impeller is removed from the casing for maintenance or inspection without removing the casing from the piping. All parts of the pumps in contact with the reactor coolant are austenitic stainless steel or equivalent corrosion-resistant materials.
The pump uses a three-stage seal arrangement. The seals control leakage, used as seal lubrication and cooling, along the pump shaft. The number 1 and 2 seals divert the majority of seal leakage to the VCT. The number 3 seal minimizes the leakage of water and vapor from the pump into the containment atmosphere. Leakage past the number 3 seal is directed to the suction of the PDTT pump.
High-pressure water flow from the charging pumps is injected into the reactor coolant pump, where a portion of the flow goes down the pump shaft past the thermal barrier to the reactor coolant system, and a portion travels up the shaft past the lower radial bearing to the number 1 seal cavity. The thermal barrier functions to cool hot reactor coolant flowing to the seal package, in the event seal injection flow is lost.
Component cooling water is supplied to the motor bearing lube oil coolers, air coolers, and the thermal barrier cooling coil. On loss-of-offsite power, the reactor coolant pumps and the component cooling pumps are de-energized due to the loss of station service and emergency stub buses. Component cooling water flow to the thermal barrier can be manually reinitiated following the restoration of the emergency stub bus after the automatic start of the diesel generators.
The squirrel cage induction motor driving the pump is air-cooled, and has oil-lubricated thrust and radial bearings. A water-lubricated bearing provides radial support for the pump shaft.
A flywheel on the shaft above the motor provides additional inertia to extend flow coastdown. Each pump contains a ratchet mechanism to prevent reverse rotation.
The original RCP motors can be replaced with motors from the North Anna plant, with appropriate compensatory measures taken. An oil collection system attaches to the original RCP motors to reduce the potential for fire in the Containment Building (see Section 9.10.4.12 for further information).
All the pressure-bearing parts of the reactor coolant pump are analyzed in accordance with Article 4 of the ASME Code,Section III. This includes the casing, the main flange, and the main
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-11 flange fasteners. The analysis includes pressure, thermal, and cyclic stresses; and these are compared with the code allowable stresses.
Mathematical methodologies are prepared and used in the analysis, which proceeds in two phases:
- 1. In the first phase, the design is checked against the design criteria of the ASME Code, with pressure stress calculations, although thermal effects are included implicitly with the experience factors. By this procedure, the shells are profiled to attain optimum metal distribution, with stress levels adequate to meet the more limiting requirements of the second phase.
- 2. In the second phase, the interactivity forces needed to maintain geometric capability between the various components are determined at design pressure and temperature, and applied to the components along with the external loads, to determine the final stress state of the components. These are finally compared with the code allowable values.
There are no other sections of the code that are specified as areas of compliance, but where code methods, allowable stresses, fabrication methods, etc., are applicable to a particular component, these are used to give a rigorous analysis and conservative design.
4.2.2.5 Pressurizer Relief Tank Principal design parameters of the pressurizer relief tank are given in Table 4.1-3.
Steam discharged from the power-operated relief valves or from the safety valves passes to the pressurizer relief tank, which is partially filled with water at or near containment ambient temperature, under a predominantly nitrogen atmosphere. Steam is discharged under the water level to condense and cool by mixing with the water. The tank is equipped with a spray, and a drain to the vent and drain system (Section 9.7), which is operated to cool the tank following a discharge.
The tank size is based on the requirement to condense and cool a discharge equivalent to 110% of volume between zero-power pressurizer water level setpoint and the high water level reactor trip setpoint.
Rupture disks protect the tank from overpressurization caused by a discharge exceeding the design value. The rupture disks, which discharge into the reactor containment, have a relief capacity in excess of the combined capacity of the pressurizer safety valves. The tank design pressure (and the rupture disk setting) is twice the calculated pressure resulting from the maximum safety valve discharge described above. This margin is to prevent deformation of the disks. The tank and rupture disk holders are also designed for full vacuum to prevent tank collapse if the tank contents cool without nitrogen being added.
The discharge piping from the safety and relief valves to the relief tank is sufficiently large to prevent backpressure at the valves from exceeding 20% of the setpoint pressure at full flow.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-12 The pressurizer relief tank, by means of its connection to the vent and drain system (Section 9.7), provides a way for removing any non-condensable gases from the reactor coolant system that might collect in the pressurizer vessel.
The tank is constructed of carbon steel with a corrosion-resistant coating on the internal surface.
4.2.2.6 Piping The general arrangement of the reactor coolant system piping is shown on the station layout drawings in Section 15.1. Piping design data are presented in Table 4.1-6.
The reactor coolant piping layout is designed on the basis of providing floating supports for the steam generators and reactor coolant pumps to absorb the thermal expansion from the fixed or anchored reactor vessel.
The austenitic stainless steel reactor coolant piping and fittings that make up the loops are 29-inch i.d. in the hot legs, 27.5-inch i.d. in the cold legs, and 31-inch i.d. between each loops steam generator outlet and its reactor coolant pump suction.
Smaller piping, including the pressurizer surge relief and spray lines, as well as drains and connections to other systems, are austenitic stainless steel. Joints and connections are welded except for stainless steel flanges such as the connections to the carbon steel pressurizer relief tank and the connections at the relief and safety valves, the MOV relief header drains, the loop flow elements, the reactor head vent piping spectacle flanges, and the reactor head vent valve pipe flanges.
Three resistance temperature detectors are installed in the hot leg of each loop near the inlet to the steam generator. One resistance temperature detector is installed in the cold leg of each loop at the discharge of the reactor coolant pump. These detectors are mounted in thermowells and provide reactor protection and control. A resistance temperature detector is also provided on each hot and cold leg to provide information when the loop is shut down.
As a result of IE Bulletin 79-27, the power supplies to each reactor coolant system loop wide-range TH-TC combination have been diversified. The associated hot-leg and cold-leg temperature loops in each reactor coolant system loop are supplied by the same vital power source, which is different from the other two TH-TC combinations. Also, the associated TH and TC instruments of each reactor coolant system loop input to their own recorder on the main control board. This modification of the wide-range temperature loops ensures that indication of differential temperature between TH and TC in at least two reactor coolant loops will be available in the event of the loss of reactor coolant pumps and any vital bus.
Thermal sleeves are installed at the following locations where high thermal stresses could otherwise develop due to rapid changes in fluid temperature during normal operational transients:
- 1. Return line from the residual heat removal loop.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-13
- 2. Both ends of the pressurizer surge line.
- 3. Pressurizer spray line connection to the pressurizer.
- 4. Charging line connection.
- 5. Loop fill header connections to each loop.
4.2.2.7 Small Valves All valve surfaces in contact with reactor coolant are austenitic stainless steel or equivalent corrosion-resistant materials. Connections to stainless steel piping are welded.
Valves that perform a modulating function are equipped with two sets of packing and an intermediate leakoff connection.
4.2.2.8 Loop Stop Valves The reactor coolant loop stop valves, one of which is shown on Figure 4.2-8, are remotely controlled, motor-operated gate valves that permit any loop to be isolated from the reactor vessel during cold or refueling shutdowns. A stop valve is installed on each hot leg and in each cold leg.
During return to service of an isolated filled loop, coolant is circulated through a bypass line, which contains a remotely controlled, motor-operated stop valve. This bypass valve is closed during normal loop operation. A valve pump interlock circuit prevents the starting of the reactor coolant pump in a given loop unless either (a) both hot leg and cold leg loop stop valves are open or (b) the cold leg loop stop valve is closed and the bypass valve is open. The interlock also prevents pump operation if the bypass valve and either of the stop valves are closed.
To ensure against an accidental start-up of an unborated and/or cold isolated loop, an additional valve interlock system is provided that meets the IEEE-279 Criteria for Nuclear Power Plant Protection Systems, August 1968. This is shown on Reference Drawing 1, which indicates a relief line and bypass around the cold-leg stop valve. These additional valve temperature and flow interlocks require that a controlled flow of reactor coolant is circulated through the relief line of the inactive loop insuring that boron concentration and temperature of the isolated loop are brought to equilibrium with the remainder of the reactor coolant system, prior to opening the cold leg loop stop valve. This controlled flow will minimize the possibility of a sudden reactivity addition from cold water or boron dilution.
The valve-temperature and valve-flow relief line interlocks are provided to:
- 1. Prevent opening of a hot-leg loop stop valve unless the cold-leg loop stop valve is closed.
- 2. Prevent opening of a cold-leg loop stop valve unless:
- a. The hot-leg loop stop valve has been opened a specified time.
- b. The loop bypass valve has been opened a specified time.
- c. Flow has existed through the relief line for a specified time.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-14
- d. The cold-leg temperature is within 20°F of the highest cold-leg temperature in other loops and the hot-leg temperature is within 20°F of the highest hot-leg temperature in the other loops.
Returning an isolated loop to service requires that the above interlocks be satisfied, a minimum temperature exists in the loop, and that core reactivity be monitored using a source range nuclear instrument channel.
If a loop was initially drained, the above interlocks can be bypassed. The initially isolated and drained loop may be returned to service by partially opening a loop stop valve and filling the loop in a controlled manner from the reactor coolant system. If using the Volume Control Tank (VCT) as the makeup source, the charging flow from the VCT is periodically sampled during the backfill evolution to ensure its boron concentration meets the minimum refueling water boron concentration requirement established by Technical Specification 3.10.A.9. Makeup to the Reactor Coolant System solely through auxiliary spray during the backfill evolution is prohibited to ensure that a sufficient fraction of makeup flow is mixed with coolant in the active Reactor Coolant System volume and flows through the core, where the source range instrumentation is available to provide secondary indication of improperly blended makeup flow. The vacuum-assisted backfill evolution involves initiation of reactor coolant pump seal injection in the isolated and drained loop to allow establishment of a partial vacuum prior to partially opening the cold leg loop stop valve. The following controls are required to assure that no sudden positive reactivity addition or loss of reactor coolant system inventory occurs during the backfill evolution:
- 1. Only one loop should be filled at a time.
- 2. The isolated loop must be verified to be drained.
- 3. Adequate reactor coolant inventory exists to assure that, during the fill operation, decay heat removal is maintained. This minimum inventory level should not be violated during the fill operation.
If this method is used to fill a loop, then the loop is no longer considered to be isolated and the requirements for returning the isolated loop to service are not applicable as long as the loop stop valves are opened within a specified time.
The parameters of each reactor coolant loop stop valve are shown in Table 4.1-7.
4.2.3 Pressure-Relieving Devices The reactor coolant system is protected automatically against overpressure by control and protective circuits such as the high-pressure trip, and by code safety valves connected to the top head of the pressurizer. The code safety and power-operated relief valves discharge into the pressurizer relief tank, which condenses and collects the valve effluent. The schematic arrangement of the relief devices is shown in Reference Drawing 2, and the valve design parameters are given in Table 4.1-3. Valve sizes are determined as indicated in Section 4.3.4.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-15 Power-operated relief valves and code safety valves are provided to protect against pressure surges which are beyond the pressure limiting capacity of the pressurizer spray. The self-actuated code safety valves provide ultimate overpressure protection; these valves are completely independent of all control and protective circuits.
The 6-in. pipes connecting the pressurizer nozzles to their respective code safety valves are shaped in the form of a loop seal. As a result of normal heat loss to the ambient, steam continually condenses in the loops. The 1-inch drain lines on the bottom of each PSV loop seal join to form a common line which connects to the pressurizer at a point approximately 30 feet below the loops.
This allows the condensate to continuously drain back to the pressurizer and prevents the accumulation of water in the loop seals.
The pressurizer code safety valves are provided with an indirect indication of valve position located in the control room. This indication is derived from temperature detectors installed in the discharge piping of each safety valve. A high temperature annunciator is provided to warn of a leaking/lifting valve.
The power-operated relief valves are also equipped with a single temperature detector downstream. A high temperature annunciator is provided to warn of a leaking/lifting valve. This system is common to both power-operated relief valves. The power-operated relief valves are equipped with redundant limit switches that provide indication of the valves being fully closed, fully open, or some intermediate position.
In addition to the above methods of monitoring valve position, the code safety valves have been equipped with acoustic sensors. Two sensors are attached to the discharge piping of each valve. One of the sensors provides active indication of flow through the valve while the other sensor is used in a passive backup capacity, capable of being utilized if necessary. The operator is alerted to a detection of flow through a valve via a flashing annunciator. The specific valve causing the annunciator alarm can be determined by an indication on the acoustic monitoring panel located in the cable spreading room. The system is powered from either Unit 1 or Unit 2 semi-vital bus with automatic transfer on loss of either units power via voltage monitoring relays.
One relief valve in the discharge piping of the RHR pumps provides a small degree of relief capacity in the event of an overpressure transient during RHR operation. The water relief capacity of the valve is 750 gpm at a backpressure of 5 psig. The RHR system relief valve is set at 600 psig and has no automatic isolation.
The pressurizer relief tank is protected against a steam discharge exceeding the design pressure value by rupture disks that discharge into the reactor containment. The rupture disk relief conditions are given in Table 4.1-3. The rupture disks are also designated as safety heads.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-16 4.2.4 Protection Against Proliferation of Dynamic Effects Essential operating and protective systems are protected from loss of function due to dynamic effects and missiles that might result from a pipe rupture1. Protection is provided by missile shielding and/or segregation of redundant components.
The reactor coolant system is surrounded by concrete shield walls. These walls provide shielding to permit access into the containment during full-power operation for inspection and maintenance of selected equipment. These shielding walls also provide missile protection for the containment liner plate.
The concrete covering over the reactor coolant system and the concrete floor under the reactor coolant system also provides for shielding and missile protection.
Steam generator restraints are provided at the upper support ring to resist lateral loads resulting from seismic and main steam line pipe rupture forces.
Missile protection afforded by the arrangement of the reactor coolant system is illustrated in the containment structure drawings given in Section 15.1. As can be seen from these drawings, protection against dynamic effects results from separation of loops by compartment walls.
4.2.5 Materials of Construction Each of the materials used in the reactor coolant system was selected for the expected environmental and service conditions. The major component materials are listed in Table 4.2-1.
All materials that are exposed to the reactor coolant are corrosion-resistant. They were chosen for specific purposes at various locations within the system and for their superior compatibility with the reactor coolant. The chemical composition of the reactor coolant is maintained within the specification given in Table 4.2-2. Reactor coolant chemistry is further discussed in Section 4.2.8. Secondary chemistry is discussed in Section 10.3.5.
The phenomena of stress-corrosion cracking and corrosion fatigue are not encountered in these materials unless a specific combination of conditions is present. The necessary conditions are a metallurgically susceptible alloy, an aggressive environment, stress, and time.
Unit 1 reactor vessel closure head has been replaced with a closure head designed for a French nuclear power plant of similar design. The code for the replacement closure head materials was the French R-CCM Code. Equivalence documents were prepared to identify equivalent ASME Code materials. Table 4.2-1 summarizes the major component materials for the closure head and provides ASME equivalent materials where appropriate. RCCM/ASME Equivalency Report - Base Materials (Reference 11) provides ASME equivalent base materials used for the pressure boundary (including structural attachments). RCCM/ASME Equivalency Report - Filler
- 1. As discussed in Section 15.6.2, it is no longer necessary to consider the dynamic effects of a postulated rupture of the primary reactor coolant loop piping. However, other pipe ruptures as discussed in Section 15.6.2 must still be considered.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-17 Materials (Reference 12) provides ASME equivalent of the filler materials used for pressure boundary and attachments welded on the closure head. RCCM/ASME Equivalency Reports -
Base Materials and RCCM/ASME Equivalency Reports for Filler Metals provides analysis and justification for deviations identified in the base materials and filler materials equivalency reports (References 11 & 12).
It is characteristic of stress corrosion that combinations of alloy and environment that result in cracking are usually quite specific. Environments that have been shown to cause stress-corrosion cracking of stainless steels are free alkalinity in the presence of a concentrating mechanism, and the presence of chlorides and free oxygen. With regard to the former, experience has shown that deposition of chemicals on tube surfaces can occur in a steam-blanketed area within a steam generator. In the presence of this environment, stress-corrosion cracking can occur in stainless steels having only the nominal residual stresses resulting from normal manufacturing procedures. However, the steam generator contains Inconel tubes. Testing to investigate the susceptibility of heat exchanger construction materials to stress corrosion in caustic and chloride aqueous solutions indicates that the Inconel alloy used has excellent resistance to general and pitting-type corrosion in severe operating water conditions.
The use of lead in the materials of the secondary side of the station is minimized except for that occurring as an insignificant trace element in metallurgical alloys.
All external insulation of reactor coolant system components is compatible with the component materials. The cylindrical shell exterior and closure flanges to the reactor vessel are insulated with metallic reflective insulation. The closure head is insulated with low halide-content insulating material. All other external corrosion-resistant surfaces in the reactor coolant system are insulated with inhibited low-halide or halide-free insulating material as required.
The stress limits established for the reactor vessel are dependent upon the temperatures at which the stresses are applied. As a result of fast neutron irradiation in the region of the core, the material properties change, including an increase in the NDTT. This was discussed in Section 4.1.7. An NDTT no greater than 40°F was set as the design limit. The material was tested to verify conformity to specified requirements and to determine the actual NDTT value. In addition, this plate was 100% volumetrically inspected by ultrasonic test using both longitudinal and shear wave methods.
The remaining material in the reactor vessel and other reactor coolant system components meets the appropriate design code requirements and specific component function.
The reactor vessel material was heat-treated specifically to obtain good notch-ductility. This ensured a low NDTT, and thereby gave assurance that the finished vessel could be initially hydrostatically tested and operated as near to room temperature as possible without restrictions.
The techniques used to measure and predict the integrated fast neutron (E greater than 1 MeV) fluxes at the sample locations are described in Section 4.1.7. The calculation method used
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-18 to obtain the maximum neutron (E greater than 1 MeV) exposure of the reactor vessel is identical to that described for the irradiation samples. Since the neutron spectra at the samples are applied with confidence to the adjacent section of reactor vessel, the maximum vessel exposure is obtained from the measured sample exposure by appropriate application of the calculated azimuthal neutron flux variation.
The estimated integrated fast neutron fluence to the reactor vessel beltline (E greater than 1 MeV, core centerline, 0° azimuthal) after 60 years of operation at a 95% capacity factor is 5.66 x 1019 n/cm2 and 5.38 x 1019 n/cm2 for Units 1 and 2, respectively. These values include the effects of the rated thermal power uprate from 2441 MWt to 2546 MWt, a MUR uprate up to 2597 MWt starting in Cycle 23 for Units 1 and 2, removal of flux suppression inserts from Unit 1, and IFBA reload core designs for Units 1 and 2. When calculated in the manner prescribed by Regulatory Guide 1.99, Revision 2, Topical Report BAW-2308, Revision 1-A and Topical Report BAW-2308, Revision 2-A, the limiting value of RTNDT is predicted to occur in the Unit 2 intermediate to lower shell circumferential weld. Unirradiated RTNDT values for reactor vessel materials are presented in Tables 4.1-14 and 4.1-15. Data used in the original design assessment of radiation-induced transition temperature increases is presented in Table 4.2-3 and Figure 4.2-9.
To evaluate the RTNDT shift of welds, heat-affected zones, and base material for the vessel, test coupons of these material types are included in the reactor vessel surveillance program described in Section 4.1.7.
4.2.6 Maximum Heat-Up and Cooldown Rates The reactor coolant system operating cycles used for design purposes are given in Table 4.1-8 and described in Section 4.1.4. During unit heat-up and cooldown, the rates of temperature and pressure changes are limited. The system design heat-up and cooldown rate of 100°F/hr satisfies stress limits for cyclic operation (ASME Vessel Code,Section III) and is consistent with the expected number of cycles. However, the normal system heat-up and cooldown rates are conservatively set at 50°F/hr. Sufficient electrical heaters are installed in the pressurizer to permit an adequate pressurizer heat-up rate of 55°F/hr when starting with a minimum water level and all pressurizer heaters in service. This rate takes into account the small continuous spray flow provided to maintain the pressurizer liquid homogeneous with the coolant.
The heat-up and cooldown rate for the pressurizer should not exceed 100°F/hr and 200°F/hr, respectively. A maximum temperature difference of 303°F between the pressurizer and reactor coolant hot leg is specified to maintain thermal stresses and fatigue in the surge line below design limits. Pressurizer spray should not be used if the temperature difference between the pressurizer and the spray fluid is greater than 320°F.
The fastest cooldown rates, which result from the hypothetical case of a break of a main steam line, are discussed in Section 14.3.2.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-19 4.2.7 Leakage 4.2.7.1 Leakage Detection Coolant leakage from the reactor coolant system to the containment is indicated in the control room by one or more of the following methods:
- 1. The containment air particulate monitoring system - A system is provided to monitor particulate activity from the areas enclosing the reactor coolant system components so that any leakage from them can be easily detected. Experience has shown that the containment air particulate monitoring system responds rapidly to primary system leakage and will provide a sensitive indication of such leakage. The curves in Figure 4.2-10 indicate the air particulate monitor response times as a function of percentage of failed fuel and rate of coolant leakage.
For example, the curves indicate, for 1% failed fuel, monitor response times of approximately 20 minutes, 6 minutes, and 2 minutes for assumed leakage rates of 10, 100, and 1000 cm3/min, respectively. Lesser quantities of failed fuel will, of course, result in increasingly longer response times.
In the range of percent failed fuel covered by Figure 4.2-10, the effect of activated corrosion products is negligible. If there is no failed fuel, the containment air particulate monitor will still detect a leak, if there are sufficient activated corrosion products present in the reactor coolant. With equilibrium activated corrosion products present in the reactor coolant, a leak of 1000 cm3/min would be detected in less than 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. Lesser quantities of activated corrosion products will result in increasingly longer response times.
The containment air particulate monitor is indicated, recorded, and alarmed in the control room.
- 2. The containment gas monitor - A system is provided to monitor gaseous activity from areas enclosing the reactor coolant system. Even though the gas monitor itself is less sensitive than the particulate monitor, the gaseous activity from any leakage is expected to be higher than the particulate activity, so that the gas monitor will also be sensitive to a leak. The containment gas monitor is indicated, recorded, and alarmed in the control room.
The capability and sensitivity of the containment gas monitor to detect primary coolant system leakage is highly dependent on the operating condition of the plant. The following three cases illustrate this:
Case 1. If there is no prior leakage into the containment and the primary coolant gaseous activity is a maximum (about 200 Ci/cm3), a leak of 0.1 gpm can be easily detected in less than 30 minutes.
Case 2. If there is no prior leakage into the containment and the primary coolant gaseous activity is 0.6 Ci/cm3 (typical of operating pressurized-water reactors), a 1-gpm leak should be detected within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-20 Case 3. If there is prior continuing leakage of 0.5 gpm into the containment and the containment gas monitor high radiation alarm setting is twice the existing steady state activity in the containment, it will take about 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> to detect a 2-gpm leak and 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to detect a 100-gpm leak, as shown in Figure 4.2-11.
- 3. Abnormal makeup water requirements - Any leakage will cause an increase in the amount of makeup water required to maintain normal level in the pressurizer. The primary-grade water and concentrated boric acid makeup flow rate are both recorded and alarmed in the control room.
- 4. Containment instrumentation - The reactor containment sump level instrumentation and the containment pressure and temperature instrumentation could all indicate leakage in the containment, but not necessarily from the primary coolant system. These measurements are also subject to variations unrelated to leakage from ruptured fluid systems. The instruments all indicate in the control room; however, it is not the primary purpose of the containment sump level and containment pressure or temperature instrumentation to detect primary coolant system leakage. Primary coolant system leakage can be most readily detected by increased makeup requirements to the primary coolant system and by the containment gas monitors.
The containment pressure and temperature are recorded by the data logger. The containment pressure also alarms in the control room.
- 5. Reactor vessel leakoff - Leakage through the reactor vessel head flange will leak off between the double o-ring seal to the leakoff provided. Leakage into this leakoff will cause high temperature in this line, which will actuate an alarm in the control room.
Methods 1 and 2 can only be used for leakage detection if there are sufficient activated products in the reactor coolant. If there are no such activated products in the reactor coolant, the other methods can be used to detect a leak.
In accordance with the information provided in Reference 2, and the safety evaluation of Reference 3, it was concluded that the reactor coolant leakage detection capability meets the staff guidelines of 1 gpm in 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
4.2.7.2 N-16 Primary to Secondary Leakage Detection System There are three N-16 leak detection channels per unit. The detectors are located adjacent to each of the main steam lines in the Mechanical Equipment Room (MER). They continuously monitor main steam and provide indication locally via Local Processing Display Units (LPDUs).
The LPDUs provide a leakrate signal to a recorder remotely in the control room for each unit. The N-16 recorder is located in the main control board vertical section. They provide a digital indication up to 1000 gallons per day of primary to secondary leakage as well as trending information. Alarm inputs are provided to the control room annunciator cabinet to alert operators of steam generator leakage and also provide an operational fault alarm in case of an internal malfunction in an N-16 channel. All LPDUs are mounted in the cable spreading rooms.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-21 The N-16 leak detection systems are designed for continuous operation. Continuous, as used to describe the operation of the N-16 leak detection systems, means that the monitors provide the required information at all times except when the system is out of service for testing or maintenance and approved alternate monitoring methods are in place.
The N-16 leak detection system is an indicating system and does not interact with any plant controlling system. Each steam generator N-16 channel provides an input to the ERF data acquisition system. The N-16 channel information is displayed on the plant computer system.
4.2.7.3 Leakage Prevention Reactor coolant system components are manufactured to normal code requirements as outlined in Section 4.1.6. Leakage through metal surfaces or welded joints is unlikely because of the welded construction of the reactor coolant system and the extensive non-destructive testing to which it is subjected.
Some leakage from the reactor coolant system is permitted by the reactor coolant pump seals. Also, all sealed joints are potential sources of leakage even though the most appropriate sealing device is selected in each case. Because of the large number of joints and the difficulty of ensuring complete freedom from leakage in each case, a small integrated leakage is considered acceptable.
All valves 3 inches or larger in lines connecting to the reactor coolant system which are normally subjected to reactor coolant system operating conditions are provided with leakoff connections. Some of these valves are equipped with backseats which limit leakage.
4.2.7.4 Locating Leaks Experience has shown that hydrostatic testing is successful in locating leaks in a pressure-containing system.
Methods of locating leaks during a station shutdown include visual observation for escaping steam or water, or of boric acid crystals near the leak. The boric acid crystals are transported outside the reactor coolant system in the leaking fluid and deposited by the evaporation process.
4.2.8 Water Chemistry The reactor coolant system water chemistry is selected to provide the necessary boron content for reactivity control and to minimize corrosion of reactor coolant system surfaces.
All materials exposed to reactor coolant are corrosion-resistant. Periodic analyses of the coolant chemical composition monitor the adherence of the system to the reactor coolant water quality listed in Table 4.2-2. Maintenance of the reactor coolant system water quality to minimize corrosion is accomplished using the chemical and volume control system and the sampling system, which are described in Sections 9.1 and 9.6, respectively.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-22 4.2.9 Reactor Coolant Flow Measurements Both the calculated system pressure drop and the pump design head contain sufficient margin to ensure a system flow rate equal to or greater than design flow rate. Straightforward hydraulics techniques are employed, together with detailed model tests using scaling techniques in accordance with Hydraulic Institute standards. This design approach has been substantiated by measurements in operating Westinghouse-designed plants.
Core safety limits are not particularly sensitive to the absolute value of reactor coolant system flow. In the course of the initial unit start-up, data pertinent to determining coolant flow, both directly and indirectly, were obtained to verify that flow was not less than design. A definite exact measurement of flow is not necessary for unit operation or for protection system purposes.
Further, there are no design provisions to vary flow, e.g. throttling devices; thus variations in absolute flow are not of concern during operation. Protection in the event of a loss of flow resulting from loss of power to one or more pumps is analyzed in Section 14.2.9.
Two methods are used in the station to measure reactor coolant system flow rate. These methods supplement each other to confirm that system flow is equal to or greater than design flow.
The methods discussed below consist of (1) a secondary heat balance coupled with coolant temperatures, and (2) elbow tap differential pressure measurements.
4.2.9.1 Secondary Heat Balance Reactor coolant system flow rate is calculated by accurately measuring the secondary system power generation together with the corresponding measured hot-leg to cold-leg temperature differential in the reactor coolant system (loop delta T). Flow is equal to power divided by the reactor coolant enthalpy decrease.
4.2.9.2 Elbow Tap Differential Pressure Measurement of the elbow tap flow meter differential pressure provides a highly repeatable measure of flow rate. The flow rate is determined from the measured 90-degree elbow differential pressure by documented (Reference 4) standard elbow characteristics.
4.2.9.3 Experience Each of the above methods is employed to obtain an independent assessment of flow. Both are evaluated in terms of consistency, one with another, as well as between loops. Possible error allowances are established on the basis of various in-plant calibrations, e.g., loop temperature.
Experience has shown that all methods used indicate greater than design flow, with good agreement between loops and reasonable agreement between methods sufficient to validate greater than design flow.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-23 4.2.9.4 Low-Flow Trip Setpoint Elbow taps are used in the reactor coolant system as an instrument device that indicates the status of reactor coolant flow. The basic function of this device is to provide information as to whether a reduction in flow rate has occurred. The correlation between flow reduction and elbow tap readout has been well established by the following equation (Reference 4):
Where:
Po = referenced pressure differential o = referenced flow rate P = pressure differential
= flow rate The full-flow reference point was established during initial unit start-up. The low-flow trip point was then established by extrapolating along the correlation curve. The technique has been used in providing core protection against low coolant flow in Westinghouse PWR plants. The expected absolute accuracy of the channel is within +/-10%. Field results have shown the repeatability of the trip point to be within +/-1%. The analysis of the loss-of-flow transient presented in Section 14.2.9 assumes an instrumentation error of +/-3%.
4.2.10 Loose Parts Monitoring System The undetected presence of loose parts or other solid objects circulating in the primary system or secondary, side of the steam generators represents an undesirable situation with regard to potential safety concerns such as flow blockage, core reactivity control, fuel damage, and degradation of the primary system pressure boundary. In addition, there is a concern over possible component damage and degradation of service life due to the impact and abrasion of the loose parts. For this reason, a loose parts monitoring system has been installed to provide the ability to monitor the primary system and secondary side of the steam generators for the presence of loose circulating parts and other foreign objects.
4.2.10.1 Design Criteria The loose parts monitoring system was designed and installed in accordance with the requirements of the appropriate edition of the ASME Code,Section III or XI, as applicable. All attachment clamps have been seismically analyzed to prevent possible damage to safety-related equipment in the event of a seismic event. The loose parts monitoring system cabinet has also been seismically analyzed and seismically mounted and supported.
The loose parts monitoring system is a non-safety-related system. The system has been reviewed for environmental qualification, and it has been determined that the requirements of IE P
Po
=
o
2
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-24 Bulletin 79-01B, NUREG-0588, and IEEE 323-1974 are not applicable. Redundancy requirements are not applicable to the loose parts monitoring system but spare channels are provided in case of instrument channel failure.
With the exception of the hard-line cable, which is Category III, the cable in the loose parts monitoring system is Category I, Class 1E, nuclear grade, flame retardant, and qualified for its intended service conditions. The hard-line cable from the reactor vessel head is routed so that it does not endanger the seismic requirements of other devices located on the reactor vessel head.
4.2.10.2 System Description The loose parts monitoring system provides the operator a means to detect and monitor the presence of a loose part or other solid object circulating freely in the primary or secondary system.
The loose parts monitoring system installed on each unit consists of 10 accelerometers, an amplifier cabinet with associated electronics, and remote alarm annunciators located in the control room. Two accelerometers are located on the reactor vessel head, two on the reactor vessel thimble tubes, one on the primary side of each of the steam generators and one on the secondary side of each steam generator.
Each accelerometer is routed to a line driver, via hardline cable, with the output of the line driver connected to twisted pair cable. The twisted pair cable is routed to the containment penetration and then to the cabinet input terminal block.
The output of each accelerometer and signal conditioner is monitored by a master alarm module. If an accelerometer detects a loose part, an alarm contact is actuated which alerts the operator to a potential loose part.
4.2.11 Loss of Decay Heat Removal Generic Letter 88-17, Loss of Decay Heat Removal, concerns the difficulties and potential consequences involved in preventing, and in recovering from, a loss of cooling to the core while the unit is shut down (References 5 though 10). The concern resulted in several initiatives to ensure adequate protection from a loss of shutdown cooling, especially during reduced inventory conditions. Reduced inventory is defined to be a RCS level lower than three feet below the reactor vessel flange. This corresponds to an inventory level of 15.7 feet elevation.
Adequate indication of RCS level and temperature, and of RHR system performance, is provided in the control room. A permanent RCS standpipe and an ultrasonic level detector are installed to ensure that at least two independent, continuous RCS level indications are monitored in the control room during reduced inventory conditions. Both level monitors provide indication, trending, and low-level alarms in the control room. Whenever the reactor vessel head is located on the reactor vessel, prior to draining the RCS to a reduced inventory condition, at least two core exit thermocouple (CET) temperature indicators are demonstrated to be operable. The CETs continuously indicate in the control room and are periodically recorded on the control room
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-25 shutdown logs. When the CETs are disconnected due to vessel disassembly, the RHR system temperature indication remains operable and available in the control room. Continuous monitoring of the RHR system performance is provided in the control room by these instruments:
suction and discharge temperature indication and trend recording, system flow indication, MOV position indication when energized, pump current indication, pump breaker status indication, system low-flow alarm, pump auto-trip alarm, pump discharge high-pressure alarm, pump cooling water low flow alarm and component cooling status (e.g. temperature, flow and pump current).
Controls are in place to implement specific actions to be taken when draining the RCS.
Those actions are based on the Westinghouse Owners Group reduced inventory project guidance and additional plant-specific analyses. The analyses consider the variables affecting time to core boiling, including RCS inventory, RCS temperature, time since shutdown, and total decay heat inventory. The analyses provide the necessary information to determine equipment and operation requirements or limitations, including:
- 1. Prior to entering a reduced inventory condition, controls are established to provide reasonable assurance containment closure can be achieved prior to the time that core uncovery could result from a loss of decay heat removal. During reduced inventory conditions, at least one boundary on each containment penetration is maintained intact, with the exception of penetrations in use or undergoing maintenance which are under administrative control. In the event of a loss of decay heat removal, a containment closure team is responsible for closing the administratively controlled penetrations.
- 2. Prior to entering a reduced inventory condition, one charging pump and one low head safety injection pump are maintained available with a specified flowpath to the core.
Administrative controls ensure that additional means of shutdown cooling or inventory make-up are also available.
- 3. Whenever possible in a reduced inventory condition, activities are avoided that could disrupt stable conditions in the RCS or RHR system, or compensatory actions are taken.
Maintenance activities are assessed prior to implementation for their potential to cause a loss of RCS inventory. Procedures include measures to prevent a loss of RHR and to enhance monitoring for early diagnosis of a loss of RHR.
- 4. To ensure that pressurization of the reactor vessel upper plenum does not occur upon a loss of cooling, procedures require that the cold leg isolation valve shall be closed first when isolating an RCS loop. When returning an RCS loop to service, the hot leg isolation valve shall be opened first. Whenever maintenance requires an opening on the cold leg during reduced inventory operation, procedural controls are in place to ensure a sufficient vent path is available.
These actions are adequate to ensure that decay heat removal capability is maintained.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-26
4.2 REFERENCES
- 1. Letter from NRC to Vepco,
Subject:
Steam Generator Program, Surry Power Station, Units 1 and 2, dated August 17, 1977, Ser. No. 351.
- 2. Letter from Vepco to NRC,
Subject:
Request for Partial Exemption from General Design Criteria 4 - Supplement, dated December 3, 1985 (Serial No. 85-136A).
- 3. Letter from NRC to Vepco transmitting Surry Unit 1 and 2 License Amendments No. 108 and related safety evaluations, dated June 16, 1986.
- 4. J. W. Murdock, Performance Characteristic of Elbow Flowmeters, Transactions of the ASME, September 1964.
- 5. VEPCO Letter Serial No.88-737, Response to Generic Letter 88-17 Loss of Decay Heat Removal, dated January 6, 1989.
- 6. VEPCO Letter Serial No. 88-737A, Response to Generic Letter 88-17 Loss of Decay Heat Removal, dated February 3, 1989.
- 7. VEPCO Letter Serial No. 88-737C, Generic Letter 88-17: Loss of Decay Heat Removal Programmed Enhancements for Instrumentation, dated October 3, 1989.
- 8. VEPCO Letter Serial No. 88-737E, Supplemental Response Generic Letter 88-17, Loss of Decay Heat Removal, dated October 5, 1990.
- 9. VEPCO Letter Serial No. 88-737D, Supplemental Response to Generic Letter 88-17 Loss of Decay Heat Removal, dated November 16, 1990.
- 10. VEPCO Letter Serial No.91-447, NRC Generic Letter 88-17, Loss of Decay Heat Removal Implementation of Programmed Enhancements, dated November 14, 1991.
- 11. Framatome ANP Document No. 38-5026914, RCCM/ASME Equivalency Report - Base Materials for Surry Unit 1 Reactor Vessel Closure Head.
- 12. Framatome ANP Document No. 39-5026915, RCCM/ASME Equivalency Report - Filler Materials for Surry Unit 1 Reactor Vessel Closure Head.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-27 4.2 REFERENCE DRAWINGS The list of Station Drawings below is provided for information only. The referenced drawings are not part of the UFSAR. This is not intended to be a complete listing of all Station Drawings referenced from this section of the UFSAR. The contents of Station Drawings are controlled by station procedure.
Drawing Number Description 1.
11448-FM-086A Flow/Valve Operating Numbers Diagram: Reactor Coolant System; Loops A, B, & C; Unit 1 11548-FM-086A Flow/Valve Operating Numbers Diagram: Reactor Coolant System; Loops A, B, & C; Unit 2 2.
11448-FM-086B Flow/Valve Operating Numbers Diagram: Reactor Coolant System, Unit 1 11548-FM-086B Flow/Valve Operating Numbers Diagram: Reactor Coolant System, Unit 2
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-28 Table 4.2-1 REACTOR COOLANT SYSTEM MATERIALS OF CONSTRUCTION Component Section Materials Reactor vessel Plate ASTM A-533B Class 1 Forgings ASTM A-508 Class 2 Cladding SS 304 equivalent and Inconel SA B166 equivalent Unit 1 closure head Plate SA-533 Type B Class 1 R-CCM 16 MND 5 (M2122)
Forgings SA-508 Grade 3 Class 1 R-CCM 16 MND 5 (M2113)
Cladding ER 309L 1st Layer ER 308L Subsequent layers Unit 2 closure head Forging SA508, Grade 3, Class 1 Cladding SS 304 equivalent Steam generator Plate ASTM A-533A Class 1 a Forgings (tubesheet)
ASTM B-508 Class 2a Cladding SS 304 equivalent Cladding for tubesheets Inconel Tubes ASTM B-163, thermally treated Support plates ASTM A-240 type 405 Channel head castings ASTM A-216 Grade WCC Pressurizer Shell SA 302 Grade B Heads SA 216 Grade WCC Support skirt SA 516 Grade 70 Nozzle weld ends b SA 182 type 316 Sockets SA 182 F316 Cladding SS 304 equivalent Internal plate SA A-240 type 304 Heat tubing SA 213 type 316 Pressurizer relief Shell ASTM A-285 Grade C Tank Heads ASTM A-385 Grade C
- a. ASTM A-533 is equivalent to ASTM A-302B. ASTM A-302B data presented elsewhere in this report are applicable to ASTM A-533B.
- b. Unit 2 surge nozzle end is SA 312 type 316. All instrument and sample nozzle ends are SA 276 type 316.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-29 Piping Pipes ASTM A-376 type 316 Fittings ASTM A-351 Group CF8M Nozzles ASTM A-182 F316 Pump Shaft ASTM A-182 Grade F304 Impeller ASTM A-351 Grade CF8 Casing ASTM A-351 Grade CF8 Valves Pressure-containing parts ASTM A-351 Grade CF8M Loop stop valves Pressure-containing parts ASTM A-351 Grade CF8M Table 4.2-1 (CONTINUED)
REACTOR COOLANT SYSTEM MATERIALS OF CONSTRUCTION Component Section Materials
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-30 Table 4.2-2 REACTOR COOLANT SYSTEM WATER CHEMISTRY SPECIFICATIONSa Electrical conductivity Determined by the concentration of boric acid and controlled chemicals present. Expected range is from less than 1 to 40 Mhos/cm at 25°C.
Solution pH Determined by the concentration of boric acid and controlled chemicals present. Expected values range between 4.2 (high boric acid concentration) to 10.5 (low boric acid concentration) at 25°C.
Oxygen, max.b 0.1 ppm Chloride, max.b 0.15 ppm Fluoride, max.b 0.15 ppm Hydrogen 5-50 cc (STP)/kg H2O Total suspended solid, max.
1.0 ppm pH control agent (Li7OH)
Determined by high temperature pH with concentration decreasing from approximately 3.5 ppm (as Li) at a RCS boron concentration of 2000 ppm until end of life cycle.
Boric acid, as ppm B Design range from 0 - 4000
- a. Applicable when the reactor is critical.
- b. Refer to the Technical Specifications for applicability.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-31 The following information is HISTORICAL and is not intended or expected to be updated for the life of the plant.
Table 4.2-3 RADIATION-INDUCED INCREASE IN TRANSITION TEMPERATURE FOR A302B STEEL Referencesa Material Temp., °F Neutron Exposure, n/cm2
(> 1 meV)
Change in
- NDTT,
°F
- 1. NRL Report 6160, p. 12 SA302B 450 5 x 1018 140
- 2. NRL Report 6160, p. 12 SA302B 550 5 x 1018 65
- 3. NRL Report 6160, p. 13 SA302B 490 1.4 x 1019 200
- 4. ASTM-STP 341, p. 226 SA302B 550 6 x 1017 30b
- 5. ASTM-STP 341, p. 226 SA302B 550 6 x 1017 45
- 6. ASTM-STP 341, p. 226 SA302B 550 8 x 1018 85b
- 7. ASTM-STP 341, p. 226 SA302B 550 8 x 1018 100
- 8. ASTM-STP 341, p. 226 SA302B 550 1.5 x 1019 130b
- 9. ASTM-STP 341, p. 226 SA302B 550 1.5 x 1019 140
- 10. NRL report 6160, p. 6 All steels 450 Various Various
- 11. Nuclear Science and Engineering 19:18-38 (1964)
SA302B 450 Various Various
- 12. Quarterly Report of Progress, Irradiation Effects on Reactor Structural Materials 11-1-64/1-31-64 SA302B 550 3 x 1019 120
- 13. Quarterly Report of Progress, Irradiation Effects on Reactor Structural Materials 11-1-64/1-31-64 SA302B 550 3 x 1019 135
- 14. Quarterly Report of Progress, Irradiation Effects on Reactor Structural Materials 11-1-64/1-31-64 SA302B 550 3 x 1019 140
- 15. Quarterly Report of Progress, Irradiation Effects on Reactor Structural Materials 11-1-64/1-31-64 SA302B 550 3 x 1019 170
- a. Applicable to Figure 4.2-9.
- b. Transverse specimens.
- c. Plotted as a 550°F data point.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-32
- 16. Quarterly Report of Progress, Irradiation Effects on Reactor Structural Materials 11-1-64/1-31-64 SA302B 550 3 x 1019 205
- 17. NRL Report 6179, p. 9 SA302B 475-540 5 x 1019 225
- 18. NRL Report 6179, p. 9 SA302B 475-540 7 x 1019 260
- 19. NRL Report 6179, p. 9 SA302B 475-540 9 x 1019 310
- 20. NRL Report 6179, p. 9 SA302B 475-540 5 x 1019 320
- 21. NRL Report 6160, p. 15 SA302B 540c 4 x 1019 200
- 22. NRL Report 6160, p. 15 SA302B 540c 3 x 1019 165
- 23. Private communication with NRL SA302B 550 3.8 x 1018 160
- 24. Progress Report, No. 1, Irradiation Tests on Reactor Pressure Vessels Steels in Br-3 Reactor Facilities, August 1965 SA302B 525 5.4 x 1018 54
- 25. Ibid.
SA302B 525 1.2 x 1019 96
- 26. Progress Report, No. 1, Irradiation Tests on Reactor Pressure Vessel Steels in Br-3 Reactor Facilities, August 1965 SA302B 600 9.5 x 1019 260
- 27. Ibid.
SA302B 600 2 x 1020 360 The following information is HISTORICAL and is not intended or expected to be updated for the life of the plant.
Table 4.2-3 (CONTINUED)
RADIATION-INDUCED INCREASE IN TRANSITION TEMPERATURE FOR A302B STEEL Referencesa Material Temp., °F Neutron Exposure, n/cm2
(> 1 meV)
Change in
- NDTT,
°F
- a. Applicable to Figure 4.2-9.
- b. Transverse specimens.
- c. Plotted as a 550°F data point.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-33 Figure 4.2-1 REACTOR COOLANT SYSTEM (UNIT 1)
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-34 Figure 4.2-2 REACTOR VESSEL SCHEMATIC (UNIT 1)
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-35 Figure 4.2-3 REACTOR VESSEL SCHEMATIC (UNIT 2)
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-36 Figure 4.2-4 PRESSURIZER
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-37 Figure 4.2-5 STEAM GENERATOR TUBE-TO-TUBESHEET JUNCTURE
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-38 Figure 4.2-6 TYPICAL REACTOR COOLANT PUMP
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-39 Figure 4.2-7 REACTOR COOLANT PUMP ESTIMATED PERFORMANCE CHARACTERISTICS
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-40 Figure 4.2-8 REACTOR COOLANT LOOP STOP VALVE
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-41 The following information is HISTORICAL and is not intended or expected to be updated for the life of the plant.
Figure 4.2-9 RADIATION INDUCED INCREASE IN TRANSITION TEMPERATURE FOR A 302-B STEEL
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-42 Figure 4.2-10 CONTAINMENT AIR PARTICULATE MONITOR RESPONSE TIME AS A FUNCTION OF PERCENTAGE OF FAILED FUEL AND RATE OF COOLANT LEAKAGE
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-43 Figure 4.2-11 CONTAINMENT GAS MONITOR MINIMUM TIME TO DETECT LEAK
Revision 52Updated Online 09/30/20 SPS UFSAR 4.2-44 Intentionally Blank
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-1 4.3 SYSTEM DESIGN EVALUATION 4.3.1 Safety Factors The safety of the reactor vessel and all other reactor coolant system pressure-containing components and piping is dependent on several major factors, including design and stress analysis, material selection and fabrication, quality control, and operations controls.
4.3.1.1 Reactor Vessel A stress evaluation of the reactor vessel was carried out in accordance with the rules of Section III of the ASME Code. The evaluation demonstrated that stress levels are within the limits of the code. Tables 4.3-1 and 4.3-2 presents a summary of the estimated stress evaluation.
Fatigue evaluations of the components having the highest cumulative usage factors including head, control rod housing, head flange, vessel flange, primary nozzles, closure studs, core support pad, bottom head to shell, and bottom instrumentation, were also performed. The evaluations show that the cumulative usage factors for these components are less than 1.0 as required by Section III of the ASME Boiler and Pressure Vessel Code, Nuclear Vessels.
The cycles specified for the fatigue analysis result from an evaluation of the expected unit operation, coupled with experience from nuclear power plants, such as Yankee-Rowe. These cycles include five heatup and cooldown cycles per year, a conservative selection and were based on the original 40-year operating license period.
The vessel design pressure is 2485 psig, while the normal operating pressure is 2235 psig.
The resulting operating membrane stress is therefore amply below the code allowable membrane stress to account for operating pressure transients.
To preclude the possibility of brittle failure, the combined pressure and thermal stresses in the reactor vessel are limited in accordance with the requirements of ASME Section XI Appendix G, which is cited in 10 CFR 50 Appendix G (Reference 1).
These stress limits are maintained by operating procedures that rely upon administrative pressure and temperature control during heatup and cooldown.
The shift in Reference Temperature for the Nil Ductility Transition (RTNDT) is established periodically during operation by testing of vessel material samples which are irradiated cumulatively by securing them near the inside wall of the vessel in the core area. To compensate for any increase in the RTNDT caused by irradiation, the limits given in the station operating manual on the pressure-temperature relationship are periodically changed to stay within the stress limits, which are stated above during heatup and cooldown. Refer to Section 4.1.7.
The vessel closure contains 58 6-inch studs. The stud material is SA-540 with a minimum yield strength of 104,400 psi at design temperature. The membrane stress in the studs at the steady-state operational condition is approximately 37,500 psi.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-2 The normal operating temperature always exceeds even the highest anticipated DTT during the life of the station. Thus, the emphasis of conservative operation is placed on heatup and cooldown because long-term irradiation of the vessel raises the DTT and thereby limits the heatup or cooldown rates. The conservatism in setting up the temperature-pressure relationship limits stated above consists of:
- 1. Use of a stress concentration factor of four on assumed flaws in calculating the stresses.
- 2. Use of nominal yield of material instead of actual yield.
- 3. Neglecting the increase in yield strength resulting from radiation effects.
As part of the initial station operator training program, Westinghouse instructed supervisory and operating personnel in reactor vessel design, fabrication, and testing, as well as present and future precautions necessary for pressure testing and operating modes. The need for record-keeping was stressed. Such records are helpful in determining the number of operating hours at various power levels and temperatures. These data are used to determine the effects of irradiation on the materials in the core region. These instructions are incorporated in the operating manuals.
The allowable stress criteria for the reactor internals indicate that for the bending state of stress, an outer fiber strain of 40% of ultimate strain is specified. This limit is equal to the average absolute strain (20% of the ultimate strain) in the cross section. If the loading is pure bending, this will give a maximum outer fiber strain of 40%. The 20% average fiber strain is 8% of the actual strain at ultimate.
The geometric shape factor does not enter directly into these strain considerations. The normal geometric shape factor that is used is 1.27 for circular piping.
The following structural elements of the reactor pressure vessel are analyzed in detail (refer to Figures 4.3-1 and 4.3-2):
A. Main closure, including adjacent shells, flange rings, and studs.
B. Inlet and outlet nozzles.
C. Core support pads and adjacent shell.
D. Transition in the cylindrical shell and transition from the cylindrical shell to bottom head.
E. Control rod drive housings.
F. Instrumentation tubes.
A description of the method of analysis for each of the above items is given below:
A. Main Closure An analytical model is used in which the cylindrical and the spherical shell courses are treated according to the thin-shell theory.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-3 The hubs, if present, are treated as either stiff rings or as a general shell. The flanges are treated as stiff rings or, when possible, partly as a shell, and the studs are treated as cantilever beams.
The deformations at the junctures between the elements are expressed in terms of thermal load, mechanical load, and redundant forces. Then the interaction analysis is performed by solving the set of equations, which is obtained by application of the equilibrium and compatibility conditions.
Once the redundant forces and displacements are known, the stresses are easily calculated.
This is done for all possible load combinations, so a complete analysis is made in which the stresses are compared with the stress and fatigue limits given by the ASME Boiler and Pressure Vessel Code,Section III.
The thermal analysis is performed by calculation of a three-dimensional model using a finite difference technique.
B. Inlet and Outlet Nozzles Including Adjacent Shell These items are analyzed by methods depending on the loads considered.
The stresses caused by internal pressure and non-uniform temperature distribution are found by means of finite element technique.
The stresses in the shell due to external forces induced by its own weight, earthquake, pipe break, etc., are calculated using the revised Bijlaard curves (Reference 2), while the stresses in the nozzle are found by treating the nozzles as cantilever beams.
The non-uniform temperature distribution due to the main thermal transient is calculated with a finite difference technique.
Finally, the stresses due to all possible load combinations are calculated for various cross sections, and compared with the applicable stress and fatigue limits.
C. Core Support Pads and Adjacent Shell The stresses in the pads due to mechanical loads are found by treating the pads as clamped cantilever beams, while the stresses in the shell are calculated with the Bijlaard curves (Reference 2).
The stresses due to steady-state temperature fluctuations are determined by means of the skin stress method.
At the end, the stresses due to the various specified load combinations are compared with the applicable stress and fatigue limits.
D. Vessel Wall Transition
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-4 The stresses in the vessel wall transition are found by treating the wall according to the thin-shell theory, with respect to the pressure stresses as well as to the temperature-induced stresses.
It is assumed that the worst temperature distribution occurs at the end of the heatup. This temperature is hand calculated. Stresses due to fast thermal transients are calculated with the formulas for skin effect stresses. The total stresses due to the possible load combinations are compared with the applicable stress and fatigue limits.
E. Control Rod Drive Housing The following paragraphs apply to Surry Unit 1 only.
The analysis of the control rod drive housing and the adjacent shell is performed in two steps.
The first step is to calculate the temperature distribution due to thermal transients using the finite difference method. The boundary condition in the thermal analysis is that in all cases the shrink fit remains, i.e., there is always conduction between the housing and the shell.
The second step is to calculate the stresses due to internal pressure, shrink fit, and temperature distribution for all load conditions. The effects due to a difference in coefficient of thermal expansion are also considered. The relative radial displacement of both housing and hole in the vessel wall is checked for all conditions to be sure that the assumed boundary condition holds. After combining the calculated stresses, the results are compared with the applicable stress and fatigue limits.
The following paragraphs apply to Surry Unit 2 only.
The analysis of the control rod drive housing and adjacent shell is performed in two steps.
The first step is to calculate the applicable thermal boundary conditions based on the design transient conditions. This is done using classical heat transfer methods. The thermal boundary conditions are applied to a finite element analysis to determine temperatures in the structure. Conduction between the adjacent shell and housing is applied in the shrink-fit region.
The second step is to calculate stresses in the housing and adjacent shell due to internal pressure and temperature distribution for all load conditions. This is also done using a finite element analysis. The effects due to a difference in coefficient of thermal expansion are considered. Shrink fit is considered in this evaluation. After combining the calculated stresses, the results are compared with the applicable stress and fatigue limits.
F. Flux Monitor Housing The analysis of the flux monitor housing is performed in the same way as for item 5. The only difference is that there exists a clearance fit between housing and shell that will remain at all load conditions.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-5 4.3.1.2 Steam Generators A stress evaluation of the steam generators was performed in accordance with Section III of the ASME Boiler and Pressure Vessel Code. Based on the stress evaluation, the critical steam generator components meet the required stress and fatigue limits of ASME Section III (1974 Edition through Winter 1976 Addendum).
The steam generator is designed to withstand a maximum primary-to-secondary pressure differential of 2485 psig coincident with a maximum temperature of 650°F. This faulted condition is postulated to result from a steam-line-break accident.
Faulted conditions are defined in paragraph N-412(t)5 of Section III of the ASME Code.
Stress limitations, based on the lower bound theorem of limit analysis for this condition, are stated in paragraph N-417.11(a & b).
The steam generator is also designed for a loss-of-coolant accident (LOCA) wherein a secondary-to-primary pressure differential of 1100 psid at 600°F can occur. This faulted condition is postulated to result from a reactor-coolant-pipe-break accident1. The above code reference is applicable.
The 1100-psid pressure differential resulting from the LOCA is less than the normal operating pressure differential of 1465 psid (2250 psia primary minus approximately 785 psia secondary). Therefore, this accident condition does not result in any stresses in the tubesheet in excess of those determined for the normal operating condition.
No significant corrosion of the Inconel tubing is expected during the lifetime of the station.
The corrosion rate reported in Reference 3 shows worst-case rates 15.9 mg/dm2 in the 2000-hour test under steam generator operating conditions. Conversion of this rate to a 60-year unit life gives a corrosion loss of less than 2.3 x 10-3 inch, which is insignificant compared to the nominal tube wall thickness of 0.050 inch.
Collapse tests of 7/8-.050 wall straight tubes at room temperature indicate that actual tube strengths are significantly higher than specification, and a collapse pressure of 6000 psi is recorded for the straight tube. The ASME Code charts indicate a collapse pressure of 2740 psi for this tube. The difference is attributed to the fact that the yield strength of the tube tested was 44,000 psi, and the code charts are based on a yield strength of approximately 29,000 psi at room temperature.
Consideration is given to the superimposed effects of secondary-side pressure loss and the design-basis earthquake loading. The fluid dynamic forces on the internal components affecting
- 1. As discussed in Section 15.6.2, leak-before-break analyses have demonstrated that the probability of rupture of the primary reactor coolant loop piping is extremely small, and it is no longer necessary to consider the dynamic effects of such an accident. However, this does not alter the primary loop LOCA as the design basis for the steam generators.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-6 the primary-secondary boundary (tubes) is considered as well. For this condition the criterion is that no rupture of primary-to-secondary boundary (tubes and tubesheet) occurs.
The fluid dynamic forces on the internals under secondary-steam-break accident conditions indicate, in the most severe case, that the tubes are adequate to constrain the motion of the baffle plates. There is some plastic deformation, but boundary integrity is maintained.
4.3.1.3 Steam Generator Tube Vibration Considerations In the design of power system steam generators, it has been recognized that an inadequately supported tube can give rise to the serious consequences of flow-induced vibration, which may lead to primary/secondary tube leakage. Historically, it has been noted that many tube vibratory failures have been due to local design configuration weaknesses such as impingement of fluid on the bundle through nozzles without protective baffle plates.
Flow induced vibration at the tubesheet caused by turbulence, fluidelastic excitation, and vortex shedding has been evaluated. These analyses have revealed that at the maximum alternating bending stress in the tube, the code allowable number of cycles is infinite and the fatigue factor is zero.
For the tube supports, the wear coefficient of the type 405 stainless steel supports is low enough to effectively maintain initial tube clearances. Although tests and calculations show that the tube support conditions will not change noticeably during the vessel life, analyses have been performed assuming loss of support at various elevations, and the alternating tube bending stress did not exceed allowed values.
The propensity for a steam generator tube rupture due to flow-induced vibration was specifically evaluated for the steam generators at the uprated conditions. The use of stainless steel essentially eliminates the potential for tube denting in the support plates. Since tube denting is a prerequisite for flow-induced vibration that can lead to tube failure, the likelihood for this type of tube degradation is not significant.
4.3.1.4 Piping Quality Assurance Quality control techniques used in the fabrication of the reactor coolant system are equivalent to those used in manufacture of the reactor vessel which conforms to Section III of the ASME Code.
The Nuclear Piping Code B31.7 is derived from ASME Section III criteria. Thus, the quality assurance requirements added by Westinghouse to USAS B31.1.0-1955 procured reactor coolant piping ensure that the quality level of a Westinghouse plant is comparable to that of Nuclear Piping Code USAS B31.7 itemized below:
- 1. The material specifications are ASTM specifications approved for nuclear use in the various code cases.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-7
- 2. The reactor system materials are non-destructively examined to levels required of Class A vessels.
- 3. Welding procedures and welders must be qualified to the requirements of Section IX of the ASME Code. The same requirement prevails in USAS B31.7.
- 4. All main primary coolant butt welds, 29, 31, and 27.5-inch o.d. are examined to the same standards required in USAS B31.7. All other butt welds are examined as required by USAS B31.1.
- 5. All nozzle welds must be radiographically examined when the branch weld is in excess of 2-inch pipe size.
- 6. All nozzle, girth, and longitudinal welds must be liquid penetrant examined. This requirement is equivalent to USAS B31.7.
- 7. Hydrostatic testing is performed in completed systems. This requirement is equivalent to USAS B31.7.
Field erection and welding procedures are governed by Westinghouse specifications, which, upon implementation, ensure that the field fabrication results in the same quality as that resulting from the shop fabrication of the same piping. In these specifications for shop fabrication and field erection are references to portions of the ASME Code.
4.3.2 Reliance on Interconnected Systems The principal heat removal systems that are interconnected with the reactor coolant system are the steam and power conversion, safety injection, and residual heat removal systems. The reactor coolant system is dependent upon the steam generators, the main steam system (Section 10.3.1), and the condensate and feedwater systems (Section 10.3.5) for stored and residual heat removal from normal operating conditions down to a reactor coolant temperature of approximately 350°F. The layout of the reactor coolant system ensures the natural circulation capability to permit unit cooldown following a loss of power to all reactor coolant pumps. The auxiliary steam generator feedwater pumps (Section 10.3.5) supply water to the steam generators in the event that the main feedwater pumps are inoperative. The safety injection system is described in Section 6.2. The residual heat removal system is described in Section 9.3.
4.3.3 System Integrity A complete stress analysis that reflects consideration of all design loadings detailed in the design specification is prepared by the manufacturer to ensure compliance with the stress limits on Section III of the ASME Boiler and Pressure Vessel Code for the reactor vessel, steam generator, reactor coolant pump casing, and pressurizer. A similar analysis of the piping is prepared by a qualified piping analyst to show compliance with the stress limits of the applicable USA Standard.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-8 As part of the design control on materials, Charpy V-notch toughness test curves are run on all ferritic material used in fabricating pressure parts of the reactor vessel, steam generator, and pressurizer to provide assurance for hydrotesting and operation in the ductile region at all times.
In addition, drop-weight tests are performed on the reactor vessel plate material.
As an assurance of system integrity, all pressure-containing components in the system were hydrotested at 3107 psig prior to initial operation.
4.3.3.1 Reactor Coolant Pump Flywheel Integrity Precautionary measures, taken to preclude missile formation from reactor coolant pump components, ensure that the pumps will not produce missiles under any anticipated accident condition.
The reactor coolant pumps run at 1189 rpm, and the controlled leakage pump assembly is capable of operation without mechanical damage with overspeeds up to and including 125% of nominal speed.
Each component of the pumps has been analyzed for missile generation. Any motor rotor fragments would be contained by the heavy stator. The same conclusion applies to the impeller, because the small fragments that might be ejected would be contained by the pump casing.
The reactor coolant pump flywheel dimensions are shown in Figure 4.3-3. As for the pump motors, the most adverse operating condition of the flywheels is considered to be the loss-of-load situation. The following conservative design-operation conditions preclude missile production by the pump flywheels. The flywheels are fabricated from rolled, vacuum-degassed, ASTM A-533 steel plates. Flywheel blanks are flame-cut from the plate, with allowance for exclusion of flame-affected metal. A minimum of three Charpy tests are made from each plate parallel and normal to the rolling direction, to determine that each blank satisfies design requirements. An NDTT less than +10°F is specified. The finished flywheels are subjected to 100% volumetric ultrasonic inspection. The finished machined bores are also subjected to magnetic particle or liquid penetrant examination. These design-fabrication techniques result in flywheels with primary stress at operating speed (shown in Figure 4.3-4) less than 50% of the minimum specified material yield strength at room temperature (100° to 150°F). A detailed evaluation has been performed to determine the critical speed for the reactor coolant pump flywheel from the standpoint of fracture and subsequent missile production. Ductile failure and brittle fracture of the flywheel were considered individually. Limiting speeds were established for each. The ductile failure limit of 3485 rpm (290% overspeed) is governing for crack sizes less than 1.15 inches, and the brittle fracture limit becomes governing for larger crack sizes. Because this crack size is very large in comparison to that which is detectable under current procedures, it is conservatively concluded that 3485 rpm is the limiting speed for the design (Reference 4).
An ultrasonic inspection capable of detecting at least 0.5-inch-deep cracks from the ends of the flywheel, and a dye penetrant or magnetic particle test of the bore, both at the end of 10 years,
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-9 were more than adequate as part of a unit surveillance program. These inspections were applicable to the first two inspection intervals.
The design specifications for the reactor coolant pumps include as a design condition the stresses generated by a design-basis earthquake ground acceleration of 0.15g. The pump would continue to run unaffected by such conditions. In no case does any bearing stress in the pump exceed or even approach a value that the bearing could not carry.
In order to preclude undetected flywheel deterioration during plant life, even though such deterioration is not expected, the flywheel will be inspected once every twenty years (Reference 14). The inspection shall be a qualified inplace UT examination over the volume from the inner bore of the flywheel to the circle of one-half the outer radius or a surface examination (MT and/or PT) of exposed surfaces defined by the volume of the disassembled flywheels.
Following a hypothetical bearing seizure, the flywheel is not expected to twist off.
Therefore, the reactor coolant pumps are not considered sources of missiles and the engineered safeguards are not in jeopardy.
4.3.3.2 Pressurized Thermal Shock The Pressurized Thermal Shock (PTS) Rule was approved by the U. S. Nuclear Regulatory Commissioners on June 20, 1985, and appeared in the Federal Register on July 23, 1985. The Code of Federal Regulations (10 CFR 50.61) contains the applicable requirements and screening criteria.
The Rule outlines regulations to address the potential for PTS events on reactor vessels in nuclear power plants. PTS events have been shown from operating experience to be transients that result in a period of severe cooldown in the primary system coincident with a high or increasing primary system pressure. The PTS concern arises if one of these transients acts on the beltline region of a reactor vessel where a reduced fracture resistance exists because of neutron irradiation. Such an event may produce the propagation of flaws postulated to exist near the inner wall surface, thereby potentially affecting the integrity of the vessel.
As part of the calculations which support the recent revisions to the Surry 1 and 2 pressure/temperature limits (References 10 & 11), RTPTS values were generated for each Surry 1 and 2 beltline material using the prescribed PTS Rule Methodology. These calculations utilized initial (unirradiated) RTNDT and end of original 40-year license fluence date presented in Reference 5. Compliance with 10 CFR 50.61 for the original 40-year license period was transmitted by References 6, 12, and 13. Reference 16 provided the most recent RTPTS values to the NRC, applicable to the current 60-year operating licenses. The results are presented in Tables 4.3-3 and 4.3-4 for Units 1 and 2, respectively. As these tables demonstrate, all RTPTS values remain below the PTS screening criteria throughout the currently licensed life of the Surry Units 1 and 2. It has been determined that all Surry Units 1 and 2 reactor vessel beltline materials meet the 10 CFR 50.61 PTS screening criteria for operation through the end of the 60-year license
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-10 period at an MUR uprated core power level (References 16 and 17).
4.3.4 Overpressure Protection The reactor coolant system is protected against overpressure by code safety valves and power-operated relief valves located on the top of the pressurizer. The safety valves on the pressurizer are sized to prevent system pressure from exceeding the design pressure by more than 10%, in accordance with Section III of the ASME Code. The capacity of the pressurizer code safety valves and power-operated relief valves is determined from considerations of the reactor protection system, and accident or transient conditions that may cause overpressure.
Mass input and heat input pressure transients were assumed, and calculations were performed to determine the low pressure overpressure protection setpoint for the power-operated relief valves (References 9 & 10).
The setpoint was chosen to ensure that 110% of the ASME Section XI Appendix G isothermal limit curve will not be exceeded during a limiting pressure transient (References 9, 10
& 11). Sufficient safety margin is provided by this setpoint, since the transient analysis shows that only one power-operated relief valve, set to open at 390 psig, is required to prevent exceeding 110% the Appendix G isothermal limit. The power-operated relief valves are set to operate as discussed above whenever the reactor coolant system is less than 350°F and the reactor head is bolted.
References 16 and 17 extended the cumulative core burnup applicability limit for the pressure/temperature limits and low temperature overpressure protection system (LTOPS) enabling temperature to 48 EFPY, included consideration of Measurement Uncertainty Recapture (MUR) uprate.
Vepco has submitted plant specific data to the NRC for safety and relief valve testing and for the power-operated relief valve block valve testing required by NUREG-0737, Item II.D.I.
This information is provided in References 7 and 8, respectively.
In Reference 7 it was concluded that the Surry Units 1 and 2 safety and relief valves, piping arrangement, and fluid inlet conditions were bounded by the valve and test parameters of the EPRI safety and relief valve test program and that the EPRI tests confirmed the ability of the safety and relief valves to open and close under the expected operating fluid conditions. In Reference 8 it was concluded that the block valve tested by EPRI was similar in design to the Surry block valves and that the valve successfully completed the evaluation and test program, fully opening and closing on demand.
4.3.4.1 Operational Conditions The operational conditions requiring overpressure protection are controlled by administrative procedures as follows:
- 1. While water-solid, only one charging pump is permitted to be operational.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-11
- 2. The safety injection accumulators must be isolated so that they do not discharge into the reactor coolant system while water-solid.
- 3. The safety injection logic must be blocked while water-solid.
- 4. The temperature of the reactor coolant system must not be more than 50°F cooler than the bulk water in the steam generators before starting the first reactor coolant pump.
4.3.4.2 Air Supply A backup air supply is provided to ensure power-operated relief valve operability in the event of a loss of the primary air supply and/or a loss of offsite power. The sizing of the redundant air supply considered both power-operated relief valve response times with the above setpoints, and assumed that operator action does not occur for 10 minutes. Annunciators are provided to alert operators of low air pressure supply. Four high-pressure air bottles are provided for each valve. Two bottles are normally aligned to the manifold, the other two are initially fully charged and used as installed spare bottle capacity. The intent is to reduce the time required to reestablish bottle pressure when a low pressure alarm occurs. Alternatively, the spare bottles may be valved in to increase the air supply available during certain modes of plant operation.
The capacity of available bottles is a function of valve stroke time and air regulator setpoint.
Valve stroke time is dependent upon the valve condition and air regulator setpoint. The air bottle volumes are each 1.74 ft3 and contain a nominal pressure of 2200 psig. The minimum pressure required to fully stroke the valve is 85 psig without assistance from Reactor Coolant System pressure. The minimum pressures required at the power operated relief valve (PORV) diaphragm to full stroke the valve at Reactor Coolant pressure of 365 psig and 2335 psig are 79 psig and 37 psig, respectively. This includes the effects of RCS pressure assistance on the required minimum backup air pressure. The following formula is used with current plant parameters and setpoints to determine required bottle capacity:
PINITIAL = PFINAL + [PCYCLE
- VCYCLE *N]/VACCUM where:
PINITIAL=
Initial pressure in the accumulator, psig PFINAL =
Final pressure in the accumulator, 100 psig PCYCLE =
Air regulator setpoint, psia VCYCLE =
Volume of air required to complete a PORV cycle, 0.126 ft3 N
=
Number of PORV cycles as analyzed for power operations or LTOPS operation VACCUM=
Total volume of the air accumulator, (total volume of bottles aligned to system, 1.74 ft3 per bottle)
The containment instrument air system header to the power-operated relief valves contains two solenoid valves in series and a backup high-pressure air supply in the line to each relief valve.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-12 Two reactor coolant system transmitters are used to provide high-pressure alarms and to control the valves. Two key-lock switches are installed in the main control board (vertical section) to permit administrative control of the system at the appropriate point during cooldown or heatup.
4.3.5 System Accident Potential The potential of the reactor coolant system as a cause of accidents was evaluated by investigating the consequences of certain credible types of component and control failures, as discussed in Sections 14.2 and 14.3. Reactor coolant pipe rupture is evaluated in Section 14.5.
As evaluated in Section 14.2, no credible component or control failure results in a DNBR less than the design DNBR limit (Section 3.2.3). Sections 14.3 and 14.5 show that for breach of the reactor coolant system boundary resulting from a steam generator tube rupture, a rod-ejection accident, or a pipe break up to and including the double-ended rupture of a reactor coolant pipe, the consequences in terms of activity releases are within the guidelines of 10 CFR 50.67 or RG 1.183, as applicable.
4.3.6 Redundancy Each loop of the reactor coolant system contains a steam generator and a reactor coolant pump. The normal power supply to the reactor coolant pumps is from electrically separate buses, as shown in Figure 8.3-1.
4.3 REFERENCES
- 1. 10 CFR 50 Appendix G, Fracture Toughness Requirements.
- 2. K. R. Wichman et al, Local Stresses in Spherical and Cylindrical Shells Due to External Loadings, Welding Research Council Bulletin, No. 107, August 1965.
- 3. W. E. Berry and F. W. Fink, The Corrosion of Inconel in High Temperature Water, Battelle Memorial Institute, April 1958.
- 4. R. Salvatori, Topical Report, Reactor Coolant Pump Integrity in a LOCA, WCAP-8163, September 1973.
- 5. M. J. DeVan, et al: Response to Closure Letters to Generic Letter 92-01, Revision 1, BAW-2222, dated June 1994.
- 6. Letter from L. H. Hartz, (Virginia Power) to USNRC, Virginia Electric and Power Company, Surry Power Station Units 1 and 2, Supplement to Response to NRC Request for Additional Information (RAI) on Generic Letter 92-01, Revision 1, Supplement 1, Serial No.99-034, dated February 24, 1999.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-13
- 7. Letter from R. H. Leasburg, Vepco, to H. R. Denton, NRC,
Subject:
Response to NUREG-0737 Post-TMI Requirement - Item II.D.1, Relief, Safety, Block Valve Test and Discharge Piping Analysis Requirements, Plant Specific Report, dated July 1, 1982 (Serial No. 392).
- 8. Letter from R. H. Leasburg, Vepco to H. R. Denton, NRC,
Subject:
Response to NUREG-0737 Post-TMI Requirement - Item II.D.1, Relief, Safety, Block Valve Test and Discharge Piping Analysis Requirements, Block Valve Reports, dated September 1, 1982 (Serial No. 514).
- 9. Letter from James P. OHanlon, (Virginia Power) to USNRC, Virginia Electric and Power Company, Surry Power Station Units 1 and 2, Request for Exemption-ASME Code Case N-514, Proposed Technical Specification Change, Revised Pressure/Temperature Limits and LTOPS Setpoint, Serial No.95-197, dated June 8, 1995.
- 10. Letter from B. C. Buckley (USNRC) to J. P. OHanlon, Surry Units 1 and 2-Issuance of Amendments Re: Surry, Units 1 and 2 Reactor Vessel Heatup and Cooldown Curves (TAC Nos. M92537 and M92538), Serial No.96-020, dated December 28, 1995.
- 11. Letter from David B. Matthews (USNRC) to J. P. OHanlon, Exemption from Requirements of 10 CFR 50.60, Acceptance Criteria for Fracture Prevention for Light-Water Nuclear Power Reactors for Normal Operation, Surry Power Station, Units 1 and 2 (TAC Nos. M92537 and M92538), Serial No.95-572, dated October 31, 1995.
- 12. Letter from L. N. Hartz to USNRC, Virginia Electric and Power Company, North Anna Power Station Units 1 and 2, Surry Power Station Units 1 and 2, Evaluation of Reactor Vessel Materials Surveillance Data, dated November 19, 1999.
- 13. Letter from L. N. Hartz to USNRC, Virginia Electric and Power Company, Surry Power Station Unit 2, Evaluation of Capsule Y Data, dated March 27, 2003.
- 14. Letter from S. R. Monarque (USNRC) to D. A. Christian, Surry Power Station Units 1 & 2 -
Issuance of Amendments to Extend the Inspection Interval for RCP Flywheels, (TAC Nos. MC4215 & MC4216), Serial No.05-413, dated June 21, 2005.
- 15. Letter from E. S. Grecheck to USNRC, Virginia Electric and Power Company Surry Power Station Units 1 and 2 Update to NRC Reactor Vessel Integrity Database and Exemption Request for Alternate Material Properties Basis Per 10 CFR 50.60(b), dated June 13, 2006.
- 16. Letter from L. N. Hartz (Dominion) to NRC, Virginia Electric and Power Company (Dominion), Surry Power Station Units 1 and 2, License Amendment Request, Measurement Uncertainty Recapture Power Uprate, Serial No.09-223, January 27, 2010.
- 17. Letter to D. A. Heacock (Dominion) from K. Cotton (USNRC), Surry Power Station, Unit Nos. 1 and 2, Issuance of Amendments Regarding Measurement Uncertainty Recapture Power Uprate (TAC Nos. ME3293 and ME3294), Dominion Serial No.10-580, dated September 24, 2010.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-14
- 18. Letter from J. A. Price to USNRC, Surry Power Station Units 1 and 2, License Amendment Request Revised Cumulative Core Burnup Applicability Limit for Heatup and Cooldown Curves, low Temperature Overpressure Protection System (LTOPS) Setpoint and LTOPS Enable Temperature, dated May 6, 2010.
- 19. Letter from Karen Cotton to (USNRC) to D. A. Heacock, Surry Power Station Unit Nos. 1 and 2, - Issuance of Amendments Regarding Reactor Vessel Heatup and Cooldown Curves For 48 effective Full-Power Years (TAC Nos. ME3920 and ME3921), Serial No.11-322, dated May 31, 2011.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-15 Table 4.3-1
SUMMARY
OF ESTIMATED PRIMARY-PLUS-SECONDARY STRESS INTENSITY FOR COMPONENTS OF THE REACTOR VESSEL - UNIT 1 Area Total Stress Intensity, psi Allowable Total Stress at Operating Temperature, psi Control rod housing 69,800 69,900 Head flange 71,700 80,000 Vessel flange 69,500 80,000 Primary nozzles 53,757 80,100 Closure studs 85,600 109,740 Core support pad 40,800 69,900 Bottom head to shell 32,736 80,100 Bottom instrumentation 56,531 69,900 Table 4.3-2
SUMMARY
OF ESTIMATED PRIMARY-PLUS-SECONDARY STRESS INTENSITY FOR COMPONENTS OF THE REACTOR VESSEL - UNIT 2 Area Total Stress Intensity, psi Allowable Total Stress at Operating Temperature, psi Control rod housing 77,500 a
Head 47,900 80,100 Vessel flange 57,700 80,100 Primary nozzles 53,757 80,100 Closure studs 87,100 110,400 Core support pad 40,800 69,900 Bottom head to shell 32,736 80,100 Bottom instrumentation 56,531 69,900
- a. The stresses in the control rod housing were determined to be acceptable using simplified elastic-plastic analysis in accordance with Paragraph NB-3228.5 of Section III of the ASME B&PV Code.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-16 Table 4.3-3 RTPTS VALUES FOR SURRY UNIT 1 Vessel Material Material Identification 48 EFPY RTPTS Value (°F)
Screening Criteria (°F)
Nozzle Shell Forging 122V109VA1 144.7 270 Intermediate Shell Plate C4326-1 148.8 270 Intermediate Shell Plate C4326-2 150.2 270 Lower Shell Plate C4415-1 158.2 270 Lower Shell Plate C4415-2 142.7 270 Nozzle to Intermediate Shell Circumferential Weld J726/25017 209.9 300 Nozzle to Intermediate Shell Circumferential Weld (ID 40%)
SA-1585/72445 226.3 300 Nozzle to Intermediate Shell Circumferential Weld (OD 60%)
SA-1650/72445 226.3 300 Intermediate Shell Longitudinal Welds L3 & L4 SA-1494/8T1554 188.6 270 Lower Shell Longitudinal Weld L1 SA-1494/8T1554 188.6 270 Lower Shell Longitudinal Weld L2 SA-1526/299L44 210.3 270 Note: This table reflects results for a cumulative core burnup of 48 EFPY which corresponds to the estimated cumulative core burnup at the end of the 60-year license period assuming a 95% capacity factor for cycles beyond Cycle 19.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-17 Table 4.3-4 RTPTS VALUES FOR SURRY UNIT 2 Vessel Material Material Identification 48 EFPY RTPTS Value (°F)
Screening Criteria Nozzle Shell Forging 123V303VA1 130.1 270 Intermediate Shell Plate C4331-2 166.6 270 Intermediate Shell Plate C4339-2 145.8 270 Lower Shell Plate C4208-2 155.9 270 Lower Shell Plate C4339-1 129.9 270 Nozzle to Intermediate Shell Circumferential Weld L737/4275 208.7 300 Intermediate to Lower Shell Circumferential Weld R3008/0227 236.4 300 Intermediate Shell Longitudinal Weld L4 (ID 50%)
WF-4/8T1762 191.1 270 Intermediate Shell Longitudinal Welds L3 (100%) and L4 (OD 50%)
SA-1585/72445 161.5 270 Lower Shell Longitudinal Welds L2 (ID 63%) and L1 (100%)
WF-4/8T1762 191.1 270 Lower Shell Longitudinal Weld L4 (OD 37%)
WF-8/8T1762 191.1 270 Note: This table reflects results for a cumulative core burnup of 48 EFPY which corresponds to the estimated cumulative core burnup at the end of the 60-year license period assuming a 95%
capacity factor for cycles beyond Cycle 18.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-18 Figure 4.3-1 REACTOR VESSEL STRESS EVALUATION SHEET 1
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-19 Figure 4.3-2 REACTOR VESSEL STRESS EVALUATION SHEET 2
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-20 Figure 4.3-3 REACTOR COOLANT PUMP FLYWHEEL DIMENSIONS
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-21 Figure 4.3-4 REACTOR COOLANT PUMP FLYWHEEL STRESSES
Revision 52Updated Online 09/30/20 SPS UFSAR 4.3-22 Intentionally Blank
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-1 4.4 TESTS AND INSPECTIONS 4.4.1 Reactor Coolant System Inspection 4.4.1.1 Non-destructive Inspection of Materials and Components Table 4.4-1 summarizes the quality assurance program for all reactor coolant system components. In this table all of the non-destructive tests and inspections required by Westinghouse specifications on reactor coolant system components and materials are specified for each component. All tests required by the applicable codes are included in this table.
Westinghouse requirements, which were more stringent in some areas than those requirements specified in the applicable codes, are also included. The fabrication and quality control techniques used in the fabrication of the reactor coolant system were equivalent to those used for the reactor vessel.
Westinghouse required, as part of its reactor vessel specification, that certain special tests, which were not specified by the applicable codes, be performed. These tests are listed below:
- 1. Ultrasonic testingWestinghouse required that a 100% volumetric ultrasonic test of reactor vessel plate for shear wave be performed in addition to code requirements. A 100%
volumetric ultrasonic test is a severe requirement, but it ensures that the plate is of the highest quality.
- 2. Irradiation surveillance testingThe cumulative effects of neutron and gamma irradiation on the reactor vessel material, including weld metal and the heat-affected zones, are monitored as described in Section 4.1.7.
Table 4.4-1 summarizes the quality assurance program with regard to inspections performed on primary system components. In addition to the inspections shown in Table 4.4-1, there were those which the equipment supplier performed to confirm the adequacy of material he received, and those performed by the material manufacturer in producing the basic material. The inspections of reactor vessel, pressurizer, and steam generator were governed by ASME Code requirements. The inspection procedures and acceptance standards required on pipe materials and piping fabrication were governed by USAS B31.1 and Westinghouse requirements, and are equivalent to those performed on ASME-coded vessels.
Procedures for performing the examinations were consistent with those established in ASME Code Section III and were reviewed by qualified engineers. These procedures were developed to provide the highest assurance of quality material and fabrication. They considered not only the size of the flaws, but, of equal importance, how the material was fabricated, the orientation and type of possible flaws, and the areas of most severe service conditions. In addition, the accessible external surfaces of the primary reactor coolant system pressure-containing segments receive a 100% surface inspection by magnetic particle or liquid penetrant testing after hydrostatic test (see Table 4.4-1). All reactor coolant system plate material was subjected to shear as well as longitudinal ultrasonic testing to give maximum assurance of
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-2 quality. All forgings received the same inspection. In addition, 100% of the material volume was covered in these tests as an added assurance over the grid basis required in the code.
Quality control engineers monitored the suppliers work, witnessing key inspections not only in the suppliers shop but in the shops of subvendors of the major forgings and plate material.
Normal surveillance included verification of records of material, physical and chemical properties, review of radiographs, performance of required tests, and qualification of supplier personnel.
Equipment specification for fabrication required that suppliers submit the manufacturing procedures (welding, heat treating, etc.) which were reviewed by qualified Westinghouse, Vepco, and Stone & Webster engineers. Field fabrication procedures were also reviewed to ensure that installation field welds were of equal quality.
Section III of the ASME Code requires that nozzles carrying significant external loads be attached to the shell by full-penetration welds. This requirement was carried out in the reactor coolant piping, where all auxiliary pipe connections to the reactor coolant loop were made using full-penetration welds.
The reactor coolant system components were welded under procedures that required the use of both pre-heat and post-heat. Pre-heat requirements, not mandatory under code rules, were performed on all weldments, including P1 and P3 materials, which are the materials of construction in the reactor vessel, pressurizer, and steam generators. Pre-heating and post-heating of weldments both served a common purpose: the production of tough, ductile metallurgical structures in the completed weldment. Pre-heating produces tough ductile welds by minimizing the formation of hard zones, whereas post-heating achieves this by tempering any hard zones which may have formed due to rapid cooling.
4.4.1.2 Electroslag Weld Quality Assurance 4.4.1.2.1 Piping Elbows The 90-degree elbows were electroslag-welded. The following were performed for quality assurance of the welding procedures:
- 1. The electroslag welding procedure employing one-wire technique was qualified in accordance with the requirements of ASME Code Section IX and Code Case 1355, plus supplementary evaluations as requested by Westinghouse. The following test specimens were removed from a 5-inch-thick weldment and successfully tested:
- a. Six transverse tensile bars - as welded.
- b. Six transverse tensile bars - 2050°F, H2O quench.
- c. Six transverse tensile bars - 2050°F, H2O + 750°F stress relief heat treatment.
- d. Six transverse tensile bars - 2050°F, H2O quench, tested at 650°F.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-3
- e. Twelve guided side bend test bars.
- 2. The casting segments were surface-conditioned for 100% radiographic and penetrant inspections. The acceptance standards were ASTM-E-186 severity level 2, except that no category D or E defectiveness was permitted, and USAS Code Case N-10, respectively.
- 3. The edges of the electroslag weld preparations were machined. These surfaces were penetrant-inspected prior to welding. The acceptance standard was USAS Code Case N-10.
- 4. The completed electroslag weld surfaces were ground flush with the casting surface. Then, the electroslag weld and adjacent base material were 100% radiographed in accordance with ASME Code Case 1355. Also, the electroslag weld surfaces and adjacent base material were penetrant-inspected in accordance with USAS Code Case N-10.
- 5. Weld metal and base metal chemical and physical analyses were determined and certified.
- 6. Heat treatment furnace charts were recorded and certified.
4.4.1.2.2 Reactor Coolant Pump Casings The reactor coolant pump casings are electroslag-welded. The following were performed for quality assurance of the components:
- 1. The electroslag welding procedure employing two-and three-wire technique was qualified in accordance with the requirements of the ASME Code Section TX and Code Case 1355, plus supplementary evaluations as requested by Westinghouse. The following test specimens were removed from an 8-inch-thick and from a 12-inch-thick weldment and successfully tested for both the two-wire and the three-wire techniques, respectively:
- a. Two-wire electroslag process, 8-inch-thick weldment.
(1) Six transverse tensile bars, 750°F post-weld stress relief.
(2) Twelve guided side bend test bars.
- b. Three-wire electroslag process, 12-inch-thick weldment.
(1) Six transverse tensile bar, 750°F post-weld stress relief.
(2) Seventeen guided side bend test bars.
(3) Twenty-one Charpy V-notch specimens.
(4) Full section macroexamination of weld-and heat-affected zones.
(5) Numerous microscopic examinations of specimens removed from the weld-and heat-affected zone regions.
(6) Hardness survey across weld-and heat-affected zones.
- 2. A separate weld test was made using the two-wire electroslag technique to evaluate the effects of a stop and restart of welding by this process. This evaluation was performed to
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-4 establish proper procedures and techniques, as such an occurrence was anticipated during production applications due to potential equipment malfunction, power outages, etc. The following test specimens were removed from an 8-inch-thick weldment in the stop-restart-repaired region and successfully tested:
- a. Two transverse tensile bars - as welded.
- b. Four guided side bend test bars.
- c. Full section macroexamination of weld-and heat-affected zone.
- 3. All of the weld test blocks in 1 and 2 above were radiographed using a 24-MeV Betatron.
The radiographic quality level (ASTM-E-94) obtained was between 0.5 to 1%. There were no discontinuities evident in any of the electroslag welds.
- a. The casting segments were surface-conditioned for 100% radiographic and penetrant inspections. The radiographic acceptance standards were ASTM-E-186 severity level 2, except that no category D or E defectiveness was permitted, for section thickness up to 4.5 inch, and ASTM-E-280 severity level 2 for section thicknesses greater than 4.5 inch.
The penetrant acceptance standards were ASME Code Section III, paragraph N-627.
- b. The edges of the electroslag weld preparations were machined. These surfaces were penetrant-inspected prior to welding. The acceptance standards were ASME Code Section III, paragraph N-627.
- c. The completed electroslag weld surfaces were ground flush with the casting surface.
Then, the electroslag weld and adjacent base material were 100% radiographed in accordance with ASME Code Case 1355. Also, the electroslag weld surfaces and adjacent base material were penetrant-inspected in accordance with ASME Code Section III, paragraph N-627.
- d. Weld metal and base metal chemical and physical analyses were determined and certified.
- e. Heat treatment furnace charts were recorded and certified.
4.4.1.3 Continuous Drive Friction Weld Process Unit 1 CRDM nozzle to adapter welds were performed by the Continuous Drive Friction process. This process is not permitted by the ASME Code Section III, but is approved by the R-CCM Code and has been used extensively for this application in non-U.S. nuclear plants. The Welding Procedure Specification (WPS), the supporting Procedure Qualification Record (PQR) and Welding Operator Performance Qualification (WPQ) were reconciled to ASME Section IX requirements for the CRDM welds. The destructive tests of the supporting PQR were compared with the required tests and criteria of the ASME Code for an equivalent full penetration weld.
These welds are deemed acceptable for this application for Surry Unit 1.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-5 4.4.1.4 Reactor Coolant System Field Erection and Welding Field erection and field welding of the reactor coolant system was performed so as to permit exact fit-up of the 31-inch i.d. closure pipe subassemblies between the steam generator and the reactor coolant pump. After installation of the pump casing and the steam generator, measurements were taken of the pipe length required to close the loop. Based on the measurements, the 31-inch i.d. closure pipe subassembly was properly machined and then erected and field-welded to the pump suction nozzle and to the steam generator exit nozzle. Thus, upon completion of the installation, the system was essentially of zero stress in the installed position.
4.4.1.5 Reactor Coolant System Cleanliness Cleaning of the reactor coolant system and associated equipment was accomplished before and/or during erection of various equipment. Stainless steel piping was cleaned in sections as specific portions of the systems were erected. Pipe and units large enough to permit entry by personnel were cleaned by locally applying approved solvents (Stoddart solvent, acetone, and alcohol) and demineralized water, and by using a rotary disk sander or 18-8 wire brush to remove all trapped foreign particles.
4.4.1.6 Reactor Coolant System Testing Following Opening For normal opening, the integrity of the system in terms of strength is unchanged. Prior to normal operation, even though it was not required, the system was pressurized to 2335 psig (operating pressure + 100 psi) to ensure leaktightness during normal operation.
For repairs on components greater than 2 inches in diameter, the thorough non-destructive testing gives a very high degree of confidence in the integrity of the system, and will detect any significant defects in and near the new welds.
Repairs on components 2 inches in diameter or smaller are relatively minor in comparison, and surface examination ensures a similar standard of integrity. In all cases, the leak test ensures leak tightness during normal operation.
4.4.1.7 Inservice Inspection Capability During the design phase of the reactor coolant system, careful consideration was given to providing access for both visual and/or non-destructive inspection. To facilitate this program, critical areas of the reactor vessel were mapped during the fabrication phase. This map serves as a reference base for subsequent ultrasonic tests.
The inservice inspection and inservice testing of ASME Code Class 1, 2, and 3 components and supports are performed in accordance with a periodically updated version of the ASME Code and Addenda, as required by 10 CFR 50.55(a). Relief from specific requirements of the Code is provided by written request for approval to the NRC.
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-6 Table 4.4-1 REACTOR COOLANT SYSTEM QUALITY ASSURANCE PROGRAM Component RTa UTa PTa MTa ETa
- 1. Steam generator 1.1 Tubesheet 1.1.1 Forging yes yes 1.1.2 Cladding yesb yesc 1.2 Channel head 1.2.1 Casting yes yes 1.2.2 Cladding yes 1.3 Secondary shell and head 1.3.1 Plates yes 1.4 Tubes yes yes 1.5 Nozzles (forgings) yes yes 1.6 Weldments 1.6.1 Shell, longitudinal yes yes 1.6.2 Shell, circumferential yes yes 1.6.3 Cladding (channel head-tubesheet joint cladding restoration) yes 1.6.4 Steam and feedwater nozzle to shell yes yes 1.6.5 Support brackets yes 1.6.6 Tube to tubesheet yes 1.6.7 Instrument connections (primary and secondary) yes 1.6.8 Temporary attachments after removal yes 1.6.9 After hydrostatic test (all welds and complete channel head-where accessible) yes 1.6.10 Nozzle safe ends yes yes 1.6.11 Nozzle safe ends (if weld deposit) yes
- a. RT-Radiographic UT-Ultrasonic PT-Dye penetrant MT-Magnetic particle ET-Eddy current
- b. Flat surfaces only
- c. Weld deposit areas only
- e. UT of clad bond-to-base metal
- f. Excluding Unit 1 and Unit 2 RVCH
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-7
- 2. Pressurizer 2.1 Heads 2.1.1 Casting yes yes 2.1.2 Cladding yes 2.2 Shell 2.2.1 Plates yes yes 2.2.2 Cladding yes 2.3 Heaters 2.3.1 Tubingd yes yes 2.3.2 Centering of element yes 2.4 Nozzle yes yes 2.5 Weldments 2.5.1 Shell, longitudinal yes yes 2.5.2 Shell, circumferential yes yes 2.5.3 Cladding yes 2.5.4 Nozzle safe end (if forging) yes yes 2.5.5 Nozzle safe end (if weld deposit) yes 2.5.6 Instrument connections yes 2.5.7 Support skirt yes 2.5.8 Temporary attachments after removal yes 2.5.9 All welds and cast heads after hydrostatic test yes 2.6 Final assembly 2.6.1 All accessible surfaces after hydrostatic test yes
- 3. Piping 3.1 Fittings (castings) yes yes 3.2 Fittings (forgings) yes yes Table 4.4-1 (CONTINUED)
REACTOR COOLANT SYSTEM QUALITY ASSURANCE PROGRAM Component RTa UTa PTa MTa ETa
- a. RT-Radiographic UT-Ultrasonic PT-Dye penetrant MT-Magnetic particle ET-Eddy current
- b. Flat surfaces only
- c. Weld deposit areas only
- e. UT of clad bond-to-base metal
- f. Excluding Unit 1 and Unit 2 RVCH
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-8
- 3. Piping (continued) 3.3 Pipe yes yes 3.4 Weldments 3.4.1 Circumferential yes yes 3.4.2 Nozzle to run pipe (No RT for nozzles less than 3 inches) yes yes 3.4.3 Instrument connections yes
- 4. Pumps 4.1 Castings yes yes 4.2 Forgings yes 4.2.1 Main shaft yes yes 4.2.2 Main studs yes yes 4.2.3 Flywheel (rolled plate) yes 4.3 Weldments 4.3.1 Circumferential yes yes 4.3.2 Instrument connections yes
- 5. Reactor vessel 5.1 Forgings 5.1.1 Flangesf yes yes 5.1.2 Studs yes yes 5.1.3 Head adaptersf yes yes 5.1.4 Head adapter tubef yes yes 5.1.5 Instrumentation tube yes yes 5.1.6 Main nozzles yes yes 5.1.7 Nozzle safe ends (if forging is employed) yes yes 5.2 Plates yes yes 5.3 Weldments 5.3.1 Main steam yes yes Table 4.4-1 (CONTINUED)
REACTOR COOLANT SYSTEM QUALITY ASSURANCE PROGRAM Component RTa UTa PTa MTa ETa
- a. RT-Radiographic UT-Ultrasonic PT-Dye penetrant MT-Magnetic particle ET-Eddy current
- b. Flat surfaces only
- c. Weld deposit areas only
- e. UT of clad bond-to-base metal
- f. Excluding Unit 1 and Unit 2 RVCH
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-9
- 5. Reactor vessel (continued) 5.3 Weldments (continued) 5.3.3 Instrumentation tube connection yes 5.3.4 Main nozzles yes yes 5.3.5 Claddingf yese yes 5.3.6 Nozzle safe ends (if forging) yes yes 5.3.7 Nozzle safe ends (if weld deposit) yes yes 5.3.9 All welds after hydrotest yes 5.4 Unit 1 Replacement RV Closure Head 5.4.1 Forgings 5.4.1.1 Flanges yes yes 5.4.1.2 Head adaptors yes yes 5.4.1.3 Head adaptor tube yes yes 5.4.2 Plates 5.4.2.1 Closure head dome yes 5.4.3 Weldments 5.4.3.1 CRD head adaptors connection to head yes 5.4.3.2 Head adaptors tube to forging yes yes 5.4.3.3 Cladding yes yes 5.4.3.4 Head lifting lugs yes yes 5.5 Unit 2 Replacement RV Closure Head 5.5.1 Forgings 5.5.1.1 Closure head yes yes 5.5.1.2 Head adapter forging yes yes 5.5.1.3 Head adapter tubing yes yes Table 4.4-1 (CONTINUED)
REACTOR COOLANT SYSTEM QUALITY ASSURANCE PROGRAM Component RTa UTa PTa MTa ETa
- a. RT-Radiographic UT-Ultrasonic PT-Dye penetrant MT-Magnetic particle ET-Eddy current
- b. Flat surfaces only
- c. Weld deposit areas only
- e. UT of clad bond-to-base metal
- f. Excluding Unit 1 and Unit 2 RVCH
Revision 52Updated Online 09/30/20 SPS UFSAR 4.4-10
- 5. Reactor vessel (continued) 5.5 Unit 2 Replacement RV Closure Head (continued) 5.5.2 Weldments 5.5.2.1 CRDM head adapters connection to head yes 5.5.2.2 RVLIS & head vent pipe connection to head yes 5.5.2.3 Cladding yes yes yes 5.5.2.4 Head lifting lugs yes yes 5.5.2.5 Head adapter forging to head adapter tube yes yes
- 6. Valves 6.1 Castings yes yes 6.2 Forgings (No UT for valves 2 inches and smaller) yes yes Table 4.4-1 (CONTINUED)
REACTOR COOLANT SYSTEM QUALITY ASSURANCE PROGRAM Component RTa UTa PTa MTa ETa
- a. RT-Radiographic UT-Ultrasonic PT-Dye penetrant MT-Magnetic particle ET-Eddy current
- b. Flat surfaces only
- c. Weld deposit areas only
- e. UT of clad bond-to-base metal
- f. Excluding Unit 1 and Unit 2 RVCH