Survey Unit Maximum IC Dose (mrem/yr)
L1-SUB-TDS 0.1439 L1-010-101 C 0.0725 B1-010-001 0.0573 B1-010-004 0.5042 L1-SUB-TDS A 0.0217 L1-SUB-TDS B 0.6373 L1-010-101 0.0251 L1-010-104 0.0837 L1-010-105 0.0131 L1-010-106 0.0624 L1-010-107 0.0674 L2-011-101 0.0804 L2-011-104 0.1050 L1-SUB-CDR 0.7314 S3-012-102 B 0.0810 S3-012-109 B 0.0791
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L1-SUB-TDS-FJGS-003-SB
-2.02E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-SUB-TDS-FJGS-003-SB 1.87E+00 1.87E+00 0.0000 0.0002 Fe-55 1.02E+07 L1-SUB-TDS-FJGS-003-SB 1.36E+00 1.36E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-FJGS-003-SB
-7.39E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-FJGS-003-SB 1.35E-02 1.35E-02 0.0011 0.0263 Ni-63 9.48E+06 L1-SUB-TDS-FJGS-003-SB 1.89E-01 1.89E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-FJGS-003-SB 6.23E-02 6.23E-02 0.0000 0.0002 Nb-94 2.02E+01 L1-SUB-TDS-FJGS-003-SB 2.60E-03 2.60E-03 0.0001 0.0032 Tc-99 3.56E+02 L1-SUB-TDS-FJGS-003-SB
-3.29E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-TDS-FJGS-003-SB 8.83E-02 8.83E-02 0.0015 0.0380 Eu-152 2.84E+01 L1-SUB-TDS-FJGS-003-SB 1.20E-03 1.20E-03 0.0000 0.0011 Eu-154 2.64E+01 L1-SUB-TDS-FJGS-003-SB
-3.90E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-TDS-FJGS-003-SB 8.40E-03 8.40E-03 0.0000 0.0002 Np-237 7.99E-01 L1-SUB-TDS-FJGS-003-SB 5.00E-04 5.00E-04 0.0006 0.0156 Pu-238 1.66E+03 L1-SUB-TDS-FJGS-003-SB
-7.20E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-SUB-TDS-FJGS-003-SB
-4.80E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-FJGS-003-SB
-4.80E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-FJGS-003-SB
-8.95E-02 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-FJGS-003-SB 4.10E-03 4.10E-03 0.0000 0.0001 Am-243 1.87E+02 L1-SUB-TDS-FJGS-003-SB 1.94E-02 1.94E-02 0.0001 0.0026 Cm-243 2.88E+02 L1-SUB-TDS-FJGS-003-SB 2.20E-03 2.20E-03 0.0000 0.0002 Cm-244 2.67E+03 L1-SUB-TDS-FJGS-003-SB 2.20E-03 2.20E-03 0.0000 0.0000 0.0221 H-3 1.75E+04 L1-SUB-TDS-FJGS-004-SB
-5.28E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-SUB-TDS-FJGS-004-SB
-8.69E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-FJGS-004-SB 2.34E+00 2.34E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-FJGS-004-SB
-1.24E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-FJGS-004-SB 5.96E-02 5.96E-02 0.0047 0.1163 Ni-63 9.48E+06 L1-SUB-TDS-FJGS-004-SB 1.98E-01 1.98E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-FJGS-004-SB 2.29E-02 2.29E-02 0.0000 0.0001 Nb-94 2.02E+01 L1-SUB-TDS-FJGS-004-SB 6.01E-03 6.01E-03 0.0003 0.0074 Tc-99 3.56E+02 L1-SUB-TDS-FJGS-004-SB 5.30E-01 5.30E-01 0.0015 0.0372 Cs-137 5.81E+01 L1-SUB-TDS-FJGS-004-SB 1.03E-01 1.03E-01 0.0018 0.0443 Eu-152 2.84E+01 L1-SUB-TDS-FJGS-004-SB 9.20E-03 9.20E-03 0.0003 0.0081 Eu-154 2.64E+01 L1-SUB-TDS-FJGS-004-SB
-3.00E-04 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-TDS-FJGS-004-SB
-3.01E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-SUB-TDS-FJGS-004-SB 0.00E+00 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-SUB-TDS-FJGS-004-SB 1.83E-02 1.83E-02 0.0000 0.0003 Pu-239 1.49E+03 L1-SUB-TDS-FJGS-004-SB
-1.70E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-FJGS-004-SB
-1.70E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-FJGS-004-SB
-1.09E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-FJGS-004-SB 1.91E-02 1.91E-02 0.0000 0.0004 Am-243 1.87E+02 L1-SUB-TDS-FJGS-004-SB 2.60E-03 2.60E-03 0.0000 0.0003 Cm-243 2.88E+02 L1-SUB-TDS-FJGS-004-SB
-4.50E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-TDS-FJGS-004-SB
-4.50E-03 0.00E+00 0.0000 0.0000 0.0457 H-3 1.75E+04 L1-SUB-TDS-FJGS-005-SB 2.93E-01 2.93E-01 0.0000 0.0004 C-14 2.45E+05 L1-SUB-TDS-FJGS-005-SB 1.40E+00 1.40E+00 0.0000 0.0001 Fe-55 1.02E+07 L1-SUB-TDS-FJGS-005-SB 1.59E-01 1.59E-01 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-FJGS-005-SB
-7.51E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-FJGS-005-SB 8.16E-02 8.16E-02 0.0064 0.1593 Ni-63 9.48E+06 L1-SUB-TDS-FJGS-005-SB 1.09E+00 1.09E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-FJGS-005-SB
-3.74E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-SUB-TDS-FJGS-005-SB
-8.00E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-SUB-TDS-FJGS-005-SB 2.89E-01 2.89E-01 0.0008 0.0203 Cs-137 5.81E+01 L1-SUB-TDS-FJGS-005-SB 1.07E-01 1.07E-01 0.0018 0.0460 Eu-152 2.84E+01 L1-SUB-TDS-FJGS-005-SB 4.80E-03 4.80E-03 0.0002 0.0042 Eu-154 2.64E+01 L1-SUB-TDS-FJGS-005-SB
-6.60E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-TDS-FJGS-005-SB 3.89E-02 3.89E-02 0.0000 0.0009 Np-237 7.99E-01 L1-SUB-TDS-FJGS-005-SB 5.00E-04 5.00E-04 0.0006 0.0156 Pu-238 1.66E+03 L1-SUB-TDS-FJGS-005-SB
-4.20E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-SUB-TDS-FJGS-005-SB 9.40E-03 9.40E-03 0.0000 0.0002 Pu-240 1.50E+03 L1-SUB-TDS-FJGS-005-SB 9.40E-03 9.40E-03 0.0000 0.0002 Pu-241 3.64E+04 L1-SUB-TDS-FJGS-005-SB
-8.41E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-FJGS-005-SB 1.15E-02 1.15E-02 0.0000 0.0003 Am-243 1.87E+02 L1-SUB-TDS-FJGS-005-SB 1.70E-02 1.70E-02 0.0001 0.0023 Cm-243 2.88E+02 L1-SUB-TDS-FJGS-005-SB
-1.50E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-TDS-FJGS-005-SB
-1.50E-03 0.00E+00 0.0000 0.0000 0.0402 H-3 1.75E+04 L1-SUB-TDS-FJGS-006-SB 3.40E-01 3.40E-01 0.0000 0.0005
C-14 2.45E+05 L1-SUB-TDS-FJGS-006-SB
-1.07E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-FJGS-006-SB 1.02E+00 1.02E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-FJGS-006-SB
-1.71E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-FJGS-006-SB 4.34E-02 4.34E-02 0.0034 0.0847 Ni-63 9.48E+06 L1-SUB-TDS-FJGS-006-SB 7.96E-01 7.96E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-FJGS-006-SB
-6.57E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-SUB-TDS-FJGS-006-SB 5.40E-03 5.40E-03 0.0003 0.0067 Tc-99 3.56E+02 L1-SUB-TDS-FJGS-006-SB 6.28E-01 6.28E-01 0.0018 0.0441 Cs-137 5.81E+01 L1-SUB-TDS-FJGS-006-SB 1.89E-01 1.89E-01 0.0033 0.0813 Eu-152 2.84E+01 L1-SUB-TDS-FJGS-006-SB 4.90E-03 4.90E-03 0.0002 0.0043 Eu-154 2.64E+01 L1-SUB-TDS-FJGS-006-SB
-4.90E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-TDS-FJGS-006-SB 3.89E-02 3.89E-02 0.0000 0.0009 Np-237 7.99E-01 L1-SUB-TDS-FJGS-006-SB 4.00E-04 4.00E-04 0.0005 0.0125 Pu-238 1.66E+03 L1-SUB-TDS-FJGS-006-SB
-4.20E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-SUB-TDS-FJGS-006-SB
-1.15E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-FJGS-006-SB
-1.15E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-FJGS-006-SB
-2.80E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-FJGS-006-SB 1.76E-02 1.76E-02 0.0000 0.0004 Am-243 1.87E+02 L1-SUB-TDS-FJGS-006-SB 9.10E-03 9.10E-03 0.0000 0.0012 Cm-243 2.88E+02 L1-SUB-TDS-FJGS-006-SB
-9.50E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-TDS-FJGS-006-SB
-9.50E-03 0.00E+00 0.0000 0.0000 0.0662 H-3 1.75E+04 L1-SUB-TDS-FJGS-007-SB 3.54E+00 3.54E+00 0.0002 0.0051 C-14 2.45E+05 L1-SUB-TDS-FJGS-007-SB
-1.72E-02 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-FJGS-007-SB 7.78E-01 7.78E-01 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-FJGS-007-SB 1.88E-01 1.88E-01 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-FJGS-007-SB 1.41E-02 1.41E-02 0.0011 0.0275 Ni-63 9.48E+06 L1-SUB-TDS-FJGS-007-SB
-8.86E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-FJGS-007-SB 1.39E-02 1.39E-02 0.0000 0.0001 Nb-94 2.02E+01 L1-SUB-TDS-FJGS-007-SB
-1.28E-02 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-SUB-TDS-FJGS-007-SB 1.58E-01 1.58E-01 0.0004 0.0111 Cs-137 5.81E+01 L1-SUB-TDS-FJGS-007-SB 3.78E-02 3.78E-02 0.0007 0.0163 Eu-152 2.84E+01 L1-SUB-TDS-FJGS-007-SB
-4.38E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-SUB-TDS-FJGS-007-SB
-1.28E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-TDS-FJGS-007-SB
-1.75E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-SUB-TDS-FJGS-007-SB 5.00E-04 5.00E-04 0.0006 0.0156 Pu-238 1.66E+03 L1-SUB-TDS-FJGS-007-SB
-2.60E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-SUB-TDS-FJGS-007-SB
-1.05E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-FJGS-007-SB
-1.05E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-FJGS-007-SB
-2.05E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-FJGS-007-SB
-1.70E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-SUB-TDS-FJGS-007-SB
-2.83E-02 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-SUB-TDS-FJGS-007-SB 1.27E-02 1.27E-02 0.0000 0.0011 Cm-244 2.67E+03 L1-SUB-TDS-FJGS-007-SB 1.27E-02 1.27E-02 0.0000 0.0001 0.0330 H-3 1.75E+04 L1-SUB-TDS-FJGS-008-SB
-1.18E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-SUB-TDS-FJGS-008-SB
-8.32E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-FJGS-008-SB 3.00E+00 3.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-FJGS-008-SB
-2.60E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-FJGS-008-SB
-9.40E-03 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-SUB-TDS-FJGS-008-SB
-1.60E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-FJGS-008-SB 1.13E-01 1.13E-01 0.0000 0.0004 Nb-94 2.02E+01 L1-SUB-TDS-FJGS-008-SB
-3.10E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-SUB-TDS-FJGS-008-SB 1.98E-01 1.98E-01 0.0006 0.0139 Cs-137 5.81E+01 L1-SUB-TDS-FJGS-008-SB 7.19E-02 7.19E-02 0.0012 0.0309 Eu-152 2.84E+01 L1-SUB-TDS-FJGS-008-SB 2.03E-03 2.03E-03 0.0001 0.0018 Eu-154 2.64E+01 L1-SUB-TDS-FJGS-008-SB 1.95E-02 1.95E-02 0.0007 0.0185 Eu-155 1.12E+03 L1-SUB-TDS-FJGS-008-SB 3.67E-02 3.67E-02 0.0000 0.0008 Np-237 7.99E-01 L1-SUB-TDS-FJGS-008-SB 1.90E-03 1.90E-03 0.0024 0.0594 Pu-238 1.66E+03 L1-SUB-TDS-FJGS-008-SB
-2.10E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-SUB-TDS-FJGS-008-SB
-4.30E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-FJGS-008-SB
-4.30E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-FJGS-008-SB
-1.34E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-FJGS-008-SB 9.40E-03 9.40E-03 0.0000 0.0002 Am-243 1.87E+02 L1-SUB-TDS-FJGS-008-SB 1.47E-02 1.47E-02 0.0001 0.0020 Cm-243 2.88E+02 L1-SUB-TDS-FJGS-008-SB 3.20E-03 3.20E-03 0.0000 0.0003 Cm-244 2.67E+03 L1-SUB-TDS-FJGS-008-SB 3.20E-03 3.20E-03 0.0000 0.0000 0.0767 H-3 1.75E+04 L1-SUB-TDS-FJGS-010-SB
-8.41E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-SUB-TDS-FJGS-010-SB
-1.01E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-FJGS-010-SB 5.15E-01 5.15E-01 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-FJGS-010-SB
-4.26E-01 0.00E+00 0.0000 0.0000
Co-60 1.28E+01 L1-SUB-TDS-FJGS-010-SB
-3.20E-03 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-SUB-TDS-FJGS-010-SB
-4.08E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-FJGS-010-SB
-5.03E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-SUB-TDS-FJGS-010-SB 1.14E-02 1.14E-02 0.0006 0.0141 Tc-99 3.56E+02 L1-SUB-TDS-FJGS-010-SB 4.23E-01 4.23E-01 0.0012 0.0297 Cs-137 5.81E+01 L1-SUB-TDS-FJGS-010-SB 5.63E-02 5.63E-02 0.0010 0.0242 Eu-152 2.84E+01 L1-SUB-TDS-FJGS-010-SB 1.62E-02 1.62E-02 0.0006 0.0142 Eu-154 2.64E+01 L1-SUB-TDS-FJGS-010-SB 3.27E-02 3.27E-02 0.0012 0.0310 Eu-155 1.12E+03 L1-SUB-TDS-FJGS-010-SB 1.32E-02 1.32E-02 0.0000 0.0003 Np-237 7.99E-01 L1-SUB-TDS-FJGS-010-SB 3.10E-03 3.10E-03 0.0039 0.0970 Pu-238 1.66E+03 L1-SUB-TDS-FJGS-010-SB
-6.60E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-SUB-TDS-FJGS-010-SB
-3.03E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-FJGS-010-SB
-3.03E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-FJGS-010-SB
-3.59E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-FJGS-010-SB
-3.40E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-SUB-TDS-FJGS-010-SB 1.75E-02 1.75E-02 0.0001 0.0023 Cm-243 2.88E+02 L1-SUB-TDS-FJGS-010-SB 5.20E-03 5.20E-03 0.0000 0.0005 Cm-244 2.67E+03 L1-SUB-TDS-FJGS-010-SB 5.20E-03 5.20E-03 0.0000 0.0000 0.1439
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L1-010-101-FSGS-C06-SB 0.0000 0.0000 C-14 2.45E+05 L1-010-101-FSGS-C06-SB 0.0000 0.0000 Fe-55 1.02E+07 L1-010-101-FSGS-C06-SB
-1.84E-01 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-101-FSGS-C06-SB
-2.26E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-101-FSGS-C06-SB 1.27E-02 1.27E-02 0.0010 0.0248 Ni-63 9.48E+06 L1-010-101-FSGS-C06-SB
-2.88E-02 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-101-FSGS-C06-SB 1.49E-01 1.49E-01 0.0000 0.0006 Nb-94 2.02E+01 L1-010-101-FSGS-C06-SB 6.15E-03 6.15E-03 0.0003 0.0076 Tc-99 3.56E+02 L1-010-101-FSGS-C06-SB
-2.25E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-101-FSGS-C06-SB 2.51E-01 2.51E-01 0.0043 0.1080 Eu-152 2.84E+01 L1-010-101-FSGS-C06-SB 1.72E-02 1.72E-02 0.0006 0.0151 Eu-154 2.64E+01 L1-010-101-FSGS-C06-SB 2.18E-02 2.18E-02 0.0008 0.0207 Eu-155 1.12E+03 L1-010-101-FSGS-C06-SB 3.28E-02 3.28E-02 0.0000 0.0007 Np-237 7.99E-01 L1-010-101-FSGS-C06-SB
-3.03E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-101-FSGS-C06-SB
-3.81E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-101-FSGS-C06-SB 2.00E-02 2.00E-02 0.0000 0.0003 Pu-240 1.50E+03 L1-010-101-FSGS-C06-SB 2.00E-02 2.00E-02 0.0000 0.0003 Pu-241 3.64E+04 L1-010-101-FSGS-C06-SB
-1.18E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-101-FSGS-C06-SB 1.63E-02 1.63E-02 0.0000 0.0004 Am-243 1.87E+02 L1-010-101-FSGS-C06-SB 2.80E-02 2.80E-02 0.0001 0.0037 Cm-243 2.88E+02 L1-010-101-FSGS-C06-SB 4.21E-03 4.21E-03 0.0000 0.0004 Cm-244 2.67E+03 L1-010-101-FSGS-C06-SB 4.21E-03 4.21E-03 0.0000 0.0000 0.0135 H-3 1.75E+04 L1-010-101-FSGS-C14-SB 0.0000 0.0000 C-14 2.45E+05 L1-010-101-FSGS-C14-SB 0.0000 0.0000 Fe-55 1.02E+07 L1-010-101-FSGS-C14-SB 3.81E+00 3.81E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-101-FSGS-C14-SB 2.09E-01 2.09E-01 0.0000 0.0000 Co-60 1.28E+01 L1-010-101-FSGS-C14-SB 8.90E-02 8.90E-02 0.0069 0.1737 Ni-63 9.48E+06 L1-010-101-FSGS-C14-SB 1.16E+00 1.16E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-101-FSGS-C14-SB
-9.77E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-101-FSGS-C14-SB 1.12E-02 1.12E-02 0.0006 0.0139 Tc-99 3.56E+02 L1-010-101-FSGS-C14-SB 5.99E-01 5.99E-01 0.0017 0.0420 Cs-137 5.81E+01 L1-010-101-FSGS-C14-SB 1.27E+00 1.27E+00 0.0219 0.5463 Eu-152 2.84E+01 L1-010-101-FSGS-C14-SB 8.54E-03 8.54E-03 0.0003 0.0075 Eu-154 2.64E+01 L1-010-101-FSGS-C14-SB 4.94E-02 4.94E-02 0.0019 0.0469 Eu-155 1.12E+03 L1-010-101-FSGS-C14-SB
-3.17E-03 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-101-FSGS-C14-SB 4.05E-04 4.05E-04 0.0005 0.0127 Pu-238 1.66E+03 L1-010-101-FSGS-C14-SB
-1.61E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-101-FSGS-C14-SB
-2.95E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-101-FSGS-C14-SB
-2.95E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-101-FSGS-C14-SB 3.02E-01 3.02E-01 0.0000 0.0002 Am-241 1.09E+03 L1-010-101-FSGS-C14-SB 2.34E-02 2.34E-02 0.0000 0.0005 Am-243 1.87E+02 L1-010-101-FSGS-C14-SB 2.38E-02 2.38E-02 0.0001 0.0032 Cm-243 2.88E+02 L1-010-101-FSGS-C14-SB
-2.96E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-101-FSGS-C14-SB
-2.96E-03 0.00E+00 0.0000 0.0000 0.0725
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose pCi/g to pCi/m2 4
9 11 4
9 11 H-3 6.54E+09 B1-010-001-CSFC-C04-CV
-1.09E+05 0.00E+00 0.0000 0.0000 2.98E+04 3
-3.65E+00
-2.41E+00
-1.22E+00 3
-1.09E+05
-7.18E+04
-3.64E+04 C-14 8.03E+08 B1-010-001-CSFC-C04-CV
-3.28E+04 0.00E+00 0.0000 0.0000 14
-1.10E+00
-2.96E-01
-3.03E+00 14
-3.28E+04
-8.82E+03
-9.03E+04 Fe-55 3.35E+10 B1-010-001-CSFC-C04-CV
-1.35E+04 0.00E+00 0.0000 0.0000 55
-4.52E-01 1.66E+00 3.42E+00 55
-1.35E+04 4.95E+04 1.02E+05 Ni-59 3.17E+11 B1-010-001-CSFC-C04-CV 5.60E+03 5.60E+03 0.0000 0.0000 59 1.88E-01 6.84E-01 6.84E-01 59 5.60E+03 2.04E+04 2.04E+04 Co-60 6.57E+06 B1-010-001-CSFC-C04-CV 1.20E+03 1.20E+03 0.0002 0.0046 60 4.03E-02 6.72E-02 3.21E-03 60 1.20E+03 2.00E+03 9.57E+01 Ni-63 1.16E+11 B1-010-001-CSFC-C04-CV
-4.32E+04 0.00E+00 0.0000 0.0000 63
-1.45E+00
-2.94E-01
-1.31E-02 63
-4.32E+04
-8.76E+03
-3.90E+02 Sr-90 1.97E+07 B1-010-001-CSFC-C04-CV 2.39E+02 2.39E+02 0.0000 0.0003 90 8.01E-03
-2.56E-02 2.30E-01 90 2.39E+02
-7.63E+02 6.85E+03 Nb-94 1.06E+07 B1-010-001-CSFC-C04-CV
-2.26E+03 0.00E+00 0.0000 0.0000 94
-7.60E-02 6.47E-02 4.12E-02 94
-2.26E+03 1.93E+03 1.23E+03 Tc-99 1.59E+08 B1-010-001-CSFC-C04-CV 2.06E+04 2.06E+04 0.0001 0.0032 99 6.91E-01
-1.48E-02
-1.65E-02 99 2.06E+04
-4.41E+02
-4.92E+02 Cs-137 2.90E+07 B1-010-001-CSFC-C04-CV 1.06E+03 1.06E+03 0.0000 0.0009 137 3.56E-02 4.82E+01 1.10E+01 137 1.06E+03 1.44E+06 3.28E+05 Eu-152 1.51E+07 B1-010-001-CSFC-C04-CV 5.01E+03 5.01E+03 0.0003 0.0083 152 1.68E-01
-2.96E-01 4.55E-02 152 5.01E+03
-8.82E+03 1.36E+03 Eu-154 1.40E+07 B1-010-001-CSFC-C04-CV
-1.90E+02 0.00E+00 0.0000 0.0000 154
-6.38E-03
-9.13E-02 7.01E-03 154
-1.90E+02
-2.72E+03 2.09E+02 Eu-155 5.81E+08 B1-010-001-CSFC-C04-CV 5.01E+03 5.01E+03 0.0000 0.0002 155 1.68E-01 1.95E-01 1.73E-01 155 5.01E+03 5.81E+03 5.16E+03 Np-237 1.86E+05 B1-010-001-CSFC-C04-CV 0.00E+00 0.00E+00 0.0000 0.0000 237 0.00E+00
-5.17E-04 3.27E-03 237 0.00E+00
-1.54E+01 9.74E+01 Pu-238 2.44E+07 B1-010-001-CSFC-C04-CV 3.73E+02 3.73E+02 0.0000 0.0004 238 1.25E-02 4.76E-03
-2.14E-02 238 3.73E+02 1.42E+02
-6.38E+02 Pu-239 2.20E+07 B1-010-001-CSFC-C04-CV 3.61E+02 3.61E+02 0.0000 0.0004 239 1.21E-02
-1.10E-02
-3.73E-03 239 3.61E+02
-3.28E+02
-1.11E+02 Pu-240 2.20E+07 B1-010-001-CSFC-C04-CV 3.61E+02 3.61E+02 0.0000 0.0004 240 1.21E-02
-1.10E-02
-3.73E-03 240 3.61E+02
-3.28E+02
-1.11E+02 Pu-241 1.11E+09 B1-010-001-CSFC-C04-CV 7.06E+01 7.06E+01 0.0000 0.0000 241.1 2.37E-03 3.12E-04
-1.67E-03 241.1 7.06E+01 9.30E+00
-4.98E+01 Am-241 3.89E+07 B1-010-001-CSFC-C04-CV 5.10E+04 5.10E+04 0.0013 0.0327 241.2 1.71E+00 2.52E-01 9.58E-01 241.2 5.10E+04 7.51E+03 2.85E+04 Am-243 2.94E+07 B1-010-001-CSFC-C04-CV
-2.32E+02 0.00E+00 0.0000 0.0000 243.1
-7.80E-03
-5.57E-03 9.25E-03 243.1
-2.32E+02
-1.66E+02 2.76E+02 Cm-243 7.89E+07 B1-010-001-CSFC-C04-CV
-1.79E+02 0.00E+00 0.0000 0.0000 243.2
-6.02E-03
-3.69E-03
-1.38E-02 243.2
-1.79E+02
-1.10E+02
-4.11E+02 Cm-244 1.79E+08 B1-010-001-CSFC-C04-CV
-1.79E+02 0.00E+00 0.0000 0.0000 0.0374 244
-6.02E-03
-3.69E-03
-1.38E-02 244
-1.79E+02
-1.10E+02
-4.11E+02 H-3 6.54E+09 B1-010-001-CSFC-C09-CV
-7.18E+04 0.00E+00 0.0000 0.0000 C-14 8.03E+08 B1-010-001-CSFC-C09-CV
-8.82E+03 0.00E+00 0.0000 0.0000 Fe-55 3.35E+10 B1-010-001-CSFC-C09-CV 4.95E+04 4.95E+04 0.0000 0.0000 Ni-59 3.17E+11 B1-010-001-CSFC-C09-CV 2.04E+04 2.04E+04 0.0000 0.0000 Co-60 6.57E+06 B1-010-001-CSFC-C09-CV 2.00E+03 2.00E+03 0.0003 0.0076 Ni-63 1.16E+11 B1-010-001-CSFC-C09-CV
-8.76E+03 0.00E+00 0.0000 0.0000 Sr-90 1.97E+07 B1-010-001-CSFC-C09-CV
-7.63E+02 0.00E+00 0.0000 0.0000 Nb-94 1.06E+07 B1-010-001-CSFC-C09-CV 1.93E+03 1.93E+03 0.0002 0.0045 Tc-99 1.59E+08 B1-010-001-CSFC-C09-CV
-4.41E+02 0.00E+00 0.0000 0.0000 Cs-137 2.90E+07 B1-010-001-CSFC-C09-CV 1.44E+06 1.44E+06 0.0495 1.2382 Eu-152 1.51E+07 B1-010-001-CSFC-C09-CV
-8.82E+03 0.00E+00 0.0000 0.0000 Eu-154 1.40E+07 B1-010-001-CSFC-C09-CV
-2.72E+03 0.00E+00 0.0000 0.0000 Eu-155 5.81E+08 B1-010-001-CSFC-C09-CV 5.81E+03 5.81E+03 0.0000 0.0003 Np-237 1.86E+05 B1-010-001-CSFC-C09-CV
-1.54E+01 0.00E+00 0.0000 0.0000 Pu-238 2.44E+07 B1-010-001-CSFC-C09-CV 1.42E+02 1.42E+02 0.0000 0.0001 Pu-239 2.20E+07 B1-010-001-CSFC-C09-CV
-3.28E+02 0.00E+00 0.0000 0.0000 Pu-240 2.20E+07 B1-010-001-CSFC-C09-CV
-3.28E+02 0.00E+00 0.0000 0.0000 Pu-241 1.11E+09 B1-010-001-CSFC-C09-CV 9.30E+00 9.30E+00 0.0000 0.0000 Am-241 3.89E+07 B1-010-001-CSFC-C09-CV 7.51E+03 7.51E+03 0.0002 0.0048 Am-243 2.94E+07 B1-010-001-CSFC-C09-CV
-1.66E+02 0.00E+00 0.0000 0.0000 Cm-243 7.89E+07 B1-010-001-CSFC-C09-CV
-1.10E+02 0.00E+00 0.0000 0.0000 Cm-244 1.79E+08 B1-010-001-CSFC-C09-CV
-1.10E+02 0.00E+00 0.0000 0.0000 0.0098 H-3 6.54E+09 B1-010-001-CSFC-C11-CV
-3.64E+04 0.00E+00 0.0000 0.0000 C-14 8.03E+08 B1-010-001-CSFC-C11-CV
-9.03E+04 0.00E+00 0.0000 0.0000 Fe-55 3.35E+10 B1-010-001-CSFC-C11-CV 1.02E+05 1.02E+05 0.0000 0.0001 Ni-59 3.17E+11 B1-010-001-CSFC-C11-CV 2.04E+04 2.04E+04 0.0000 0.0000 Co-60 6.57E+06 B1-010-001-CSFC-C11-CV 9.57E+01 9.57E+01 0.0000 0.0004 Ni-63 1.16E+11 B1-010-001-CSFC-C11-CV
-3.90E+02 0.00E+00 0.0000 0.0000 Sr-90 1.97E+07 B1-010-001-CSFC-C11-CV 6.85E+03 6.85E+03 0.0003 0.0087 Nb-94 1.06E+07 B1-010-001-CSFC-C11-CV 1.23E+03 1.23E+03 0.0001 0.0029 Tc-99 1.59E+08 B1-010-001-CSFC-C11-CV
-4.92E+02 0.00E+00 0.0000 0.0000 Cs-137 2.90E+07 B1-010-001-CSFC-C11-CV 3.28E+05 3.28E+05 0.0113 0.2826 Eu-152 1.51E+07 B1-010-001-CSFC-C11-CV 1.36E+03 1.36E+03 0.0001 0.0022 Eu-154 1.40E+07 B1-010-001-CSFC-C11-CV 2.09E+02 2.09E+02 0.0000 0.0004 Eu-155 5.81E+08 B1-010-001-CSFC-C11-CV 5.16E+03 5.16E+03 0.0000 0.0002 Np-237 1.86E+05 B1-010-001-CSFC-C11-CV 9.74E+01 9.74E+01 0.0005 0.0131 Pu-238 2.44E+07 B1-010-001-CSFC-C11-CV
-6.38E+02 0.00E+00 0.0000 0.0000 Pu-239 2.20E+07 B1-010-001-CSFC-C11-CV
-1.11E+02 0.00E+00 0.0000 0.0000 Pu-240 2.20E+07 B1-010-001-CSFC-C11-CV
-1.11E+02 0.00E+00 0.0000 0.0000 Pu-241 1.11E+09 B1-010-001-CSFC-C11-CV
-4.98E+01 0.00E+00 0.0000 0.0000 Am-241 3.89E+07 B1-010-001-CSFC-C11-CV 2.85E+04 2.85E+04 0.0007 0.0183 Am-243 2.94E+07 B1-010-001-CSFC-C11-CV 2.76E+02 2.76E+02 0.0000 0.0002 Cm-243 7.89E+07 B1-010-001-CSFC-C11-CV
-4.11E+02 0.00E+00 0.0000 0.0000 Cm-244 1.79E+08 B1-010-001-CSFC-C11-CV
-4.11E+02 0.00E+00 0.0000 0.0000 0.0349 H-3 1.75E+04 B1-010-001-CIGS-BG02-SB
-9.50E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 B1-010-001-CIGS-BG02-SB
-2.11E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 B1-010-001-CIGS-BG02-SB 2.10E+00 2.10E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-001-CIGS-BG02-SB
-9.26E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-001-CIGS-BG02-SB 1.42E-03 1.42E-03 0.0001 0.0028 Ni-63 9.48E+06 B1-010-001-CIGS-BG02-SB
-9.05E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 B1-010-001-CIGS-BG02-SB
-8.69E-03 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 B1-010-001-CIGS-BG02-SB 6.13E-03 6.13E-03 0.0003 0.0076 Tc-99 3.56E+02 B1-010-001-CIGS-BG02-SB 1.01E-01 1.01E-01 0.0003 0.0071 Cs-137 5.81E+01 B1-010-001-CIGS-BG02-SB 5.35E-01 5.35E-01 0.0092 0.2301 Eu-152 2.84E+01 B1-010-001-CIGS-BG02-SB 5.51E-03 5.51E-03 0.0002 0.0048 Eu-154 2.64E+01 B1-010-001-CIGS-BG02-SB
-2.52E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 B1-010-001-CIGS-BG02-SB 5.29E-03 5.29E-03 0.0000 0.0001 Np-237 7.99E-01 B1-010-001-CIGS-BG02-SB
-7.71E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 B1-010-001-CIGS-BG02-SB
-6.16E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 B1-010-001-CIGS-BG02-SB
-8.02E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 B1-010-001-CIGS-BG02-SB
-8.02E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 B1-010-001-CIGS-BG02-SB 3.05E-01 3.05E-01 0.0000 0.0002 Am-241 1.09E+03 B1-010-001-CIGS-BG02-SB 1.51E-02 1.51E-02 0.0000 0.0003 Am-243 1.87E+02 B1-010-001-CIGS-BG02-SB 4.42E-02 4.42E-02 0.0002 0.0059 Cm-243 2.88E+02 B1-010-001-CIGS-BG02-SB
-7.32E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 B1-010-001-CIGS-BG02-SB
-7.32E-03 0.00E+00 0.0000 0.0000 0.0213 H-3 1.75E+04 B1-010-001-CIGS-BH02-SB 3.87E-01 3.87E-01 0.0000 0.0006 C-14 2.45E+05 B1-010-001-CIGS-BH02-SB
-3.37E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 B1-010-001-CIGS-BH02-SB 1.36E+00 1.36E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-001-CIGS-BH02-SB 2.05E-01 2.05E-01 0.0000 0.0000 Co-60 1.28E+01 B1-010-001-CIGS-BH02-SB
-1.65E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 B1-010-001-CIGS-BH02-SB
-1.76E+00 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 B1-010-001-CIGS-BH02-SB
-1.07E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 B1-010-001-CIGS-BH02-SB
-3.42E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 B1-010-001-CIGS-BH02-SB
-2.42E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 B1-010-001-CIGS-BH02-SB 1.33E-01 1.33E-01 0.0023 0.0572 Eu-152 2.84E+01 B1-010-001-CIGS-BH02-SB
-1.01E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 B1-010-001-CIGS-BH02-SB
-4.41E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 B1-010-001-CIGS-BH02-SB
-2.97E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 B1-010-001-CIGS-BH02-SB
-1.06E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 B1-010-001-CIGS-BH02-SB 5.82E-03 5.82E-03 0.0000 0.0001 Pu-239 1.49E+03 B1-010-001-CIGS-BH02-SB 4.15E-04 4.15E-04 0.0000 0.0000 Pu-240 1.50E+03 B1-010-001-CIGS-BH02-SB 4.15E-04 4.15E-04 0.0000 0.0000 Pu-241 3.64E+04 B1-010-001-CIGS-BH02-SB 7.48E-01 7.48E-01 0.0000 0.0005 Am-241 1.09E+03 B1-010-001-CIGS-BH02-SB 2.93E-02 2.93E-02 0.0000 0.0007 Am-243 1.87E+02 B1-010-001-CIGS-BH02-SB
-5.30E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 B1-010-001-CIGS-BH02-SB 3.19E-04 3.19E-04 0.0000 0.0000 Cm-244 2.67E+03 B1-010-001-CIGS-BH02-SB 3.19E-04 3.19E-04 0.0000 0.0000 0.0019 H-3 1.75E+04 B1-010-001-CIGS-BJ02-SB 7.13E-01 7.13E-01 0.0000 0.0010 C-14 2.45E+05 B1-010-001-CIGS-BJ02-SB 1.82E+00 1.82E+00 0.0000 0.0002 Fe-55 1.02E+07 B1-010-001-CIGS-BJ02-SB 2.29E+00 2.29E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-001-CIGS-BJ02-SB 6.79E-01 6.79E-01 0.0000 0.0000 Co-60 1.28E+01 B1-010-001-CIGS-BJ02-SB
-5.00E-04 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 B1-010-001-CIGS-BJ02-SB
-1.66E+00 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 B1-010-001-CIGS-BJ02-SB 4.55E-02 4.55E-02 0.0000 0.0002 Nb-94 2.02E+01 B1-010-001-CIGS-BJ02-SB
-1.13E-02 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 B1-010-001-CIGS-BJ02-SB 3.43E-01 3.43E-01 0.0010 0.0241 Cs-137 5.81E+01 B1-010-001-CIGS-BJ02-SB 4.64E-03 4.64E-03 0.0001 0.0020 Eu-152 2.84E+01 B1-010-001-CIGS-BJ02-SB 8.60E-03 8.60E-03 0.0003 0.0076 Eu-154 2.64E+01 B1-010-001-CIGS-BJ02-SB 1.34E-02 1.34E-02 0.0005 0.0127 Eu-155 1.12E+03 B1-010-001-CIGS-BJ02-SB 6.07E-02 6.07E-02 0.0001 0.0014 Np-237 7.99E-01 B1-010-001-CIGS-BJ02-SB 8.98E-04 8.98E-04 0.0011 0.0281 Pu-238 1.66E+03 B1-010-001-CIGS-BJ02-SB
-1.08E-02 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 B1-010-001-CIGS-BJ02-SB
-9.27E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 B1-010-001-CIGS-BJ02-SB
-9.27E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 B1-010-001-CIGS-BJ02-SB 9.11E-01 9.11E-01 0.0000 0.0006 Am-241 1.09E+03 B1-010-001-CIGS-BJ02-SB 9.43E-03 9.43E-03 0.0000 0.0002 Am-243 1.87E+02 B1-010-001-CIGS-BJ02-SB
-2.59E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 B1-010-001-CIGS-BJ02-SB 1.78E-02 1.78E-02 0.0001 0.0015 Cm-244 2.67E+03 B1-010-001-CIGS-BJ02-SB 1.78E-02 1.78E-02 0.0000 0.0002 0.0573 H-3 1.75E+04 B1-010-001-CIGS-BK01-SB
-2.39E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 B1-010-001-CIGS-BK01-SB
-6.86E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 B1-010-001-CIGS-BK01-SB 7.44E-01 7.44E-01 0.0000 0.0000 Ni-59 2.59E+07 B1-010-001-CIGS-BK01-SB 1.95E+00 1.95E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-001-CIGS-BK01-SB
-1.00E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 B1-010-001-CIGS-BK01-SB
-8.80E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 B1-010-001-CIGS-BK01-SB 5.75E-02 5.75E-02 0.0000 0.0002 Nb-94 2.02E+01 B1-010-001-CIGS-BK01-SB
-2.79E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 B1-010-001-CIGS-BK01-SB
-4.95E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 B1-010-001-CIGS-BK01-SB
-5.04E-03 0.00E+00 0.0000 0.0000 Eu-152 2.84E+01 B1-010-001-CIGS-BK01-SB
-1.21E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 B1-010-001-CIGS-BK01-SB
-1.49E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 B1-010-001-CIGS-BK01-SB 6.89E-03 6.89E-03 0.0000 0.0002 Np-237 7.99E-01 B1-010-001-CIGS-BK01-SB 6.32E-04 6.32E-04 0.0008 0.0198 Pu-238 1.66E+03 B1-010-001-CIGS-BK01-SB
-4.78E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 B1-010-001-CIGS-BK01-SB 1.09E-02 1.09E-02 0.0000 0.0002 Pu-240 1.50E+03 B1-010-001-CIGS-BK01-SB 1.09E-02 1.09E-02 0.0000 0.0002 Pu-241 3.64E+04 B1-010-001-CIGS-BK01-SB
-1.63E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 B1-010-001-CIGS-BK01-SB 4.67E-03 4.67E-03 0.0000 0.0001 Am-243 1.87E+02 B1-010-001-CIGS-BK01-SB 1.61E-02 1.61E-02 0.0001 0.0022 Cm-243 2.88E+02 B1-010-001-CIGS-BK01-SB 1.26E-02 1.26E-02 0.0000 0.0011 Cm-244 2.67E+03 B1-010-001-CIGS-BK01-SB 1.26E-02 1.26E-02 0.0000 0.0001 0.0238
RadionuclideUnadjusted DCGL Sample Activity (pCi/g)Activity (pCi/g) (zero)Fraction Dose IC Dose pCi/g to pCi/m2 9
10 11 12 13 14 15 16 9
10 11 12 13 14 15 16 H-3 5.91E+09 B1-010-04A-CJFC-009-CV 1.06E+05 1.06E+05 0.0000 0.0005 2.98E+04 3
3.57E+00 4.83E+00 4.29E+00 2.01E+00 1.82E+00 5.15E+00 3.73E+00 3.91E+00 3
1.06E+05 1.44E+05 1.28E+05 5.99E+04 5.42E+04 1.53E+05 1.11E+05 1.17E+05 C-14 5.33E+08 B1-010-04A-CJFC-009-CV
-2.10E+04 0.00E+00 0.0000 0.0000 14
-7.04E-01
-2.34E-01
-6.72E-01 9.23E-01
-1.84E+00
-1.42E-02 1.10E+00 5.25E-01 14
-2.10E+04
-6.97E+03
-2.00E+04 2.75E+04
-5.48E+04
-4.23E+02 3.28E+04 1.56E+04 Fe-55 2.32E+10 B1-010-04A-CJFC-009-CV
-8.79E+04 0.00E+00 0.0000 0.0000 55
-2.95E+00
-3.71E+00 2.68E+00
-5.75E+00
-5.77E+00
-4.84E+00 1.97E+00
-4.20E+00 55
-8.79E+04
-1.11E+05 7.99E+04
-1.71E+05
-1.72E+05
-1.44E+05 5.87E+04
-1.25E+05 Ni-59 2.09E+11 B1-010-04A-CJFC-009-CV
-6.56E+03 0.00E+00 0.0000 0.0000 59
-2.20E-01
-2.48E-01 1.01E+00
-1.35E-01
-1.81E+00 2.53E-01
-2.99E-01 5.11E-01 59
-6.56E+03
-7.39E+03 3.01E+04
-4.02E+03
-5.39E+04 7.54E+03
-8.91E+03 1.52E+04 Co-60 6.42E+06 B1-010-04A-CJFC-009-CV 7.45E+02 7.45E+02 0.0001 0.0029 60 2.50E-02 6.69E-02 0.00E+00 1.13E-01 2.66E-01 2.46E-01
-4.03E-02 6.93E-02 60 7.45E+02 1.99E+03 0.00E+00 3.37E+03 7.93E+03 7.33E+03
-1.20E+03 2.07E+03 Ni-63 8.49E+10 B1-010-04A-CJFC-009-CV 2.73E+04 2.73E+04 0.0000 0.0000 63 9.15E-01 6.41E+00 2.08E+00 2.70E+00 1.00E+01 1.07E+01 1.43E+00 1.33E+00 63 2.73E+04 1.91E+05 6.20E+04 8.05E+04 2.98E+05 3.19E+05 4.26E+04 3.96E+04 Sr-90 1.18E+07 B1-010-04A-CJFC-009-CV 3.04E+03 3.04E+03 0.0003 0.0064 90 1.02E-01 2.28E-01 1.06E-01
-2.88E-02 1.28E-01 1.09E-01
-2.17E-01
-4.27E-02 90 3.04E+03 6.79E+03 3.16E+03
-8.58E+02 3.81E+03 3.25E+03
-6.47E+03
-1.27E+03 Nb-94 1.05E+07 B1-010-04A-CJFC-009-CV
-8.37E+02 0.00E+00 0.0000 0.0000 94
-2.81E-02 3.72E-02 4.28E-02
-8.53E-04 3.00E-03
-3.79E-03 3.67E-02 1.01E-02 94
-8.37E+02 1.11E+03 1.28E+03
-2.54E+01 8.94E+01
-1.13E+02 1.09E+03 3.01E+02 Tc-99 1.50E+08 B1-010-04A-CJFC-009-CV 1.96E+03 1.96E+03 0.0000 0.0003 99 6.59E-02
-5.60E-01
-4.18E-01
-6.56E-01
-4.98E-01 2.86E+00
-5.31E-01
-5.50E-02 99 1.96E+03
-1.67E+04
-1.25E+04
-1.95E+04
-1.48E+04 8.52E+04
-1.58E+04
-1.64E+03 Cs-137 2.82E+07 B1-010-04A-CJFC-009-CV 1.59E+05 1.59E+05 0.0056 0.1405 137 5.32E+00 9.57E+00 6.02E+00 4.66E+00 2.54E+02 1.37E+02
-7.21E-03 6.64E+00 137 1.59E+05 2.85E+05 1.79E+05 1.39E+05 7.57E+06 4.08E+06
-2.15E+02 1.98E+05 Eu-152 1.51E+07 B1-010-04A-CJFC-009-CV 2.57E+03 2.57E+03 0.0002 0.0043 152 8.62E-02
-3.75E-02 5.35E-02 8.38E-03
-7.97E-01 3.33E-01 1.63E-02 1.08E-01 152 2.57E+03
-1.12E+03 1.59E+03 2.50E+02
-2.38E+04 9.92E+03 4.86E+02 3.22E+03 Eu-154 1.39E+07 B1-010-04A-CJFC-009-CV
-4.35E+03 0.00E+00 0.0000 0.0000 154
-1.46E-01
-9.50E-02
-5.66E-02
-2.99E-02
-3.84E-02
-1.01E-01
-6.24E-02 1.12E-01 154
-4.35E+03
-2.83E+03
-1.69E+03
-8.91E+02
-1.14E+03
-3.01E+03
-1.86E+03 3.34E+03 Eu-155 5.77E+08 B1-010-04A-CJFC-009-CV 2.00E+03 2.00E+03 0.0000 0.0001 155 6.72E-02 1.65E-01 7.12E-02 8.03E-02 8.70E-02 7.52E-02 1.70E-01
-8.62E-02 155 2.00E+03 4.92E+03 2.12E+03 2.39E+03 2.59E+03 2.24E+03 5.07E+03
-2.57E+03 Np-237 1.51E+05 B1-010-04A-CJFC-009-CV 3.04E+03 3.04E+03 0.0201 0.5032 237 1.02E-01
-1.19E-02 3.15E-02
-4.88E-02
-6.24E-02
-9.56E-03 1.83E-02 8.66E-03 237 3.04E+03
-3.55E+02 9.39E+02
-1.45E+03
-1.86E+03
-2.85E+02 5.45E+02 2.58E+02 Pu-238 1.77E+07 B1-010-04A-CJFC-009-CV
-1.05E+02 0.00E+00 0.0000 0.0000 238
-3.53E-03 1.64E-02 6.04E-03
-8.73E-03 1.73E-01 2.33E-01 2.16E-03 1.79E-02 238
-1.05E+02 4.89E+02 1.80E+02
-2.60E+02 5.16E+03 6.94E+03 6.44E+01 5.33E+02 Pu-239 1.46E+07 B1-010-04A-CJFC-009-CV
-1.05E+02 0.00E+00 0.0000 0.0000 239
-3.52E-03
-1.07E-02 3.62E-03
-1.02E-02 8.46E-02 2.70E-01 2.07E-02
-1.58E-03 239
-1.05E+02
-3.19E+02 1.08E+02
-3.04E+02 2.52E+03 8.05E+03 6.17E+02
-4.71E+01 Pu-240 1.46E+07 B1-010-04A-CJFC-009-CV
-1.05E+02 0.00E+00 0.0000 0.0000 240
-3.52E-03
-1.07E-02 3.62E-03
-1.02E-02 8.46E-02 2.70E-01 2.07E-02
-1.58E-03 240
-1.05E+02
-3.19E+02 1.08E+02
-3.04E+02 2.52E+03 8.05E+03 6.17E+02
-4.71E+01 Pu-241 7.81E+08 B1-010-04A-CJFC-009-CV
-6.11E+03 0.00E+00 0.0000 0.0000 241.1
-2.05E-01 9.58E-01 2.11E-01
-1.92E+00 4.40E+00 5.59E+00 4.22E-01 6.92E-01 241.1
-6.11E+03 2.85E+04 6.29E+03
-5.72E+04 1.31E+05 1.67E+05 1.26E+04 2.06E+04 Am-241 2.75E+07 B1-010-04A-CJFC-009-CV
-4.47E+02 0.00E+00 0.0000 0.0000 241.2
-1.50E-02 2.69E-02 4.40E-02 3.12E-02 5.05E-01 6.83E-01 5.13E-03 5.20E-02 241.2
-4.47E+02 8.02E+02 1.31E+03 9.30E+02 1.50E+04 2.04E+04 1.53E+02 1.55E+03 Am-243 2.16E+07 B1-010-04A-CJFC-009-CV
-1.24E+02 0.00E+00 0.0000 0.0000 243.1
-4.15E-03 3.87E-03 1.57E-02 4.43E-02
-1.06E-02 1.27E-02 4.36E-03 5.06E-04 243.1
-1.24E+02 1.15E+02 4.68E+02 1.32E+03
-3.16E+02 3.78E+02 1.30E+02 1.51E+01 Cm-243 6.66E+07 B1-010-04A-CJFC-009-CV 9.98E+01 9.98E+01 0.0000 0.0000 243.2 3.35E-03 7.57E-03 1.93E-03 4.92E-04
-2.57E-03 1.30E-02 5.10E-03
-3.40E-03 243.2 9.98E+01 2.26E+02 5.75E+01 1.47E+01
-7.66E+01 3.87E+02 1.52E+02
-1.01E+02 Cm-244 1.34E+08 B1-010-04A-CJFC-009-CV 9.98E+01 9.98E+01 0.0000 0.0000 0.5042 244 3.35E-03 7.57E-03 1.93E-03 4.92E-04
-2.57E-03 1.30E-02 5.10E-03
-3.40E-03 244 9.98E+01 2.26E+02 5.75E+01 1.47E+01
-7.66E+01 3.87E+02 1.52E+02
-1.01E+02 H-3 5.91E+09 B1-010-04A-CJFC-010-CV 1.44E+05 1.44E+05 0.0000 0.0006 C-14 5.33E+08 B1-010-04A-CJFC-010-CV
-6.97E+03 0.00E+00 0.0000 0.0000 Fe-55 2.32E+10 B1-010-04A-CJFC-010-CV
-1.11E+05 0.00E+00 0.0000 0.0000 Ni-59 2.09E+11 B1-010-04A-CJFC-010-CV
-7.39E+03 0.00E+00 0.0000 0.0000 Co-60 6.42E+06 B1-010-04A-CJFC-010-CV 1.99E+03 1.99E+03 0.0003 0.0078 Ni-63 8.49E+10 B1-010-04A-CJFC-010-CV 1.91E+05 1.91E+05 0.0000 0.0001 Sr-90 1.18E+07 B1-010-04A-CJFC-010-CV 6.79E+03 6.79E+03 0.0006 0.0144 Nb-94 1.05E+07 B1-010-04A-CJFC-010-CV 1.11E+03 1.11E+03 0.0001 0.0026 Tc-99 1.50E+08 B1-010-04A-CJFC-010-CV
-1.67E+04 0.00E+00 0.0000 0.0000 Cs-137 2.82E+07 B1-010-04A-CJFC-010-CV 2.85E+05 2.85E+05 0.0101 0.2528 Eu-152 1.51E+07 B1-010-04A-CJFC-010-CV
-1.12E+03 0.00E+00 0.0000 0.0000 Eu-154 1.39E+07 B1-010-04A-CJFC-010-CV
-2.83E+03 0.00E+00 0.0000 0.0000 Eu-155 5.77E+08 B1-010-04A-CJFC-010-CV 4.92E+03 4.92E+03 0.0000 0.0002 Np-237 1.51E+05 B1-010-04A-CJFC-010-CV
-3.55E+02 0.00E+00 0.0000 0.0000 Pu-238 1.77E+07 B1-010-04A-CJFC-010-CV 4.89E+02 4.89E+02 0.0000 0.0007 Pu-239 1.46E+07 B1-010-04A-CJFC-010-CV
-3.19E+02 0.00E+00 0.0000 0.0000 Pu-240 1.46E+07 B1-010-04A-CJFC-010-CV
-3.19E+02 0.00E+00 0.0000 0.0000 Pu-241 7.81E+08 B1-010-04A-CJFC-010-CV 2.85E+04 2.85E+04 0.0000 0.0009 Am-241 2.75E+07 B1-010-04A-CJFC-010-CV 8.02E+02 8.02E+02 0.0000 0.0007 Am-243 2.16E+07 B1-010-04A-CJFC-010-CV 1.15E+02 1.15E+02 0.0000 0.0001 Cm-243 6.66E+07 B1-010-04A-CJFC-010-CV 2.26E+02 2.26E+02 0.0000 0.0001 Cm-244 1.34E+08 B1-010-04A-CJFC-010-CV 2.26E+02 2.26E+02 0.0000 0.0000 0.0061 H-3 5.91E+09 B1-010-04A-CJFC-011-CV 1.28E+05 1.28E+05 0.0000 0.0005 C-14 5.33E+08 B1-010-04A-CJFC-011-CV
-2.00E+04 0.00E+00 0.0000 0.0000 Fe-55 2.32E+10 B1-010-04A-CJFC-011-CV 7.99E+04 7.99E+04 0.0000 0.0001 Ni-59 2.09E+11 B1-010-04A-CJFC-011-CV 3.01E+04 3.01E+04 0.0000 0.0000 Co-60 6.42E+06 B1-010-04A-CJFC-011-CV 0.00E+00 0.00E+00 0.0000 0.0000 Ni-63 8.49E+10 B1-010-04A-CJFC-011-CV 6.20E+04 6.20E+04 0.0000 0.0000 Sr-90 1.18E+07 B1-010-04A-CJFC-011-CV 3.16E+03 3.16E+03 0.0003 0.0067 Nb-94 1.05E+07 B1-010-04A-CJFC-011-CV 1.28E+03 1.28E+03 0.0001 0.0030 Tc-99 1.50E+08 B1-010-04A-CJFC-011-CV
-1.25E+04 0.00E+00 0.0000 0.0000 Cs-137 2.82E+07 B1-010-04A-CJFC-011-CV 1.79E+05 1.79E+05 0.0064 0.1590 Eu-152 1.51E+07 B1-010-04A-CJFC-011-CV 1.59E+03 1.59E+03 0.0001 0.0026 Eu-154 1.39E+07 B1-010-04A-CJFC-011-CV
-1.69E+03 0.00E+00 0.0000 0.0000 Eu-155 5.77E+08 B1-010-04A-CJFC-011-CV 2.12E+03 2.12E+03 0.0000 0.0001 Np-237 1.51E+05 B1-010-04A-CJFC-011-CV 9.39E+02 9.39E+02 0.0062 0.1554 Pu-238 1.77E+07 B1-010-04A-CJFC-011-CV 1.80E+02 1.80E+02 0.0000 0.0003 Pu-239 1.46E+07 B1-010-04A-CJFC-011-CV 1.08E+02 1.08E+02 0.0000 0.0002 Pu-240 1.46E+07 B1-010-04A-CJFC-011-CV 1.08E+02 1.08E+02 0.0000 0.0002 Pu-241 7.81E+08 B1-010-04A-CJFC-011-CV 6.29E+03 6.29E+03 0.0000 0.0002 Am-241 2.75E+07 B1-010-04A-CJFC-011-CV 1.31E+03 1.31E+03 0.0000 0.0012 Am-243 2.16E+07 B1-010-04A-CJFC-011-CV 4.68E+02 4.68E+02 0.0000 0.0005 Cm-243 6.66E+07 B1-010-04A-CJFC-011-CV 5.75E+01 5.75E+01 0.0000 0.0000 Cm-244 1.34E+08 B1-010-04A-CJFC-011-CV 5.75E+01 5.75E+01 0.0000 0.0000 0.1618 H-3 5.91E+09 B1-010-04A-CJFC-012-CV 5.99E+04 5.99E+04 0.0000 0.0003 C-14 5.33E+08 B1-010-04A-CJFC-012-CV 2.75E+04 2.75E+04 0.0001 0.0013 Fe-55 2.32E+10 B1-010-04A-CJFC-012-CV
-1.71E+05 0.00E+00 0.0000 0.0000 Ni-59 2.09E+11 B1-010-04A-CJFC-012-CV
-4.02E+03 0.00E+00 0.0000 0.0000 Co-60 6.42E+06 B1-010-04A-CJFC-012-CV 3.37E+03 3.37E+03 0.0005 0.0131 Ni-63 8.49E+10 B1-010-04A-CJFC-012-CV 8.05E+04 8.05E+04 0.0000 0.0000 Sr-90 1.18E+07 B1-010-04A-CJFC-012-CV
-8.58E+02 0.00E+00 0.0000 0.0000 Nb-94 1.05E+07 B1-010-04A-CJFC-012-CV
-2.54E+01 0.00E+00 0.0000 0.0000 Tc-99 1.50E+08 B1-010-04A-CJFC-012-CV
-1.95E+04 0.00E+00 0.0000 0.0000 Cs-137 2.82E+07 B1-010-04A-CJFC-012-CV 1.39E+05 1.39E+05 0.0049 0.1231 Eu-152 1.51E+07 B1-010-04A-CJFC-012-CV 2.50E+02 2.50E+02 0.0000 0.0004 Eu-154 1.39E+07 B1-010-04A-CJFC-012-CV
-8.91E+02 0.00E+00 0.0000 0.0000 Eu-155 5.77E+08 B1-010-04A-CJFC-012-CV 2.39E+03 2.39E+03 0.0000 0.0001 Np-237 1.51E+05 B1-010-04A-CJFC-012-CV
-1.45E+03 0.00E+00 0.0000 0.0000 Pu-238 1.77E+07 B1-010-04A-CJFC-012-CV
-2.60E+02 0.00E+00 0.0000 0.0000 Pu-239 1.46E+07 B1-010-04A-CJFC-012-CV
-3.04E+02 0.00E+00 0.0000 0.0000 Pu-240 1.46E+07 B1-010-04A-CJFC-012-CV
-3.04E+02 0.00E+00 0.0000 0.0000 Pu-241 7.81E+08 B1-010-04A-CJFC-012-CV
-5.72E+04 0.00E+00 0.0000 0.0000 Am-241 2.75E+07 B1-010-04A-CJFC-012-CV 9.30E+02 9.30E+02 0.0000 0.0008 Am-243 2.16E+07 B1-010-04A-CJFC-012-CV 1.32E+03 1.32E+03 0.0001 0.0015 Cm-243 6.66E+07 B1-010-04A-CJFC-012-CV 1.47E+01 1.47E+01 0.0000 0.0000 Cm-244 1.34E+08 B1-010-04A-CJFC-012-CV 1.47E+01 1.47E+01 0.0000 0.0000 0.0041 H-3 5.91E+09 B1-010-04A-CJFC-013-CV 5.42E+04 5.42E+04 0.0000 0.0002 C-14 5.33E+08 B1-010-04A-CJFC-013-CV
-5.48E+04 0.00E+00 0.0000 0.0000 Fe-55 2.32E+10 B1-010-04A-CJFC-013-CV
-1.72E+05 0.00E+00 0.0000 0.0000 Ni-59 2.09E+11 B1-010-04A-CJFC-013-CV
-5.39E+04 0.00E+00 0.0000 0.0000 Co-60 6.42E+06 B1-010-04A-CJFC-013-CV 7.93E+03 7.93E+03 0.0012 0.0309 Ni-63 8.49E+10 B1-010-04A-CJFC-013-CV 2.98E+05 2.98E+05 0.0000 0.0001 Sr-90 1.18E+07 B1-010-04A-CJFC-013-CV 3.81E+03 3.81E+03 0.0003 0.0081 Nb-94 1.05E+07 B1-010-04A-CJFC-013-CV 8.94E+01 8.94E+01 0.0000 0.0002 Tc-99 1.50E+08 B1-010-04A-CJFC-013-CV
-1.48E+04 0.00E+00 0.0000 0.0000 Cs-137 2.82E+07 B1-010-04A-CJFC-013-CV 7.57E+06 7.57E+06 0.2684 6.7103 Eu-152 1.51E+07 B1-010-04A-CJFC-013-CV
-2.38E+04 0.00E+00 0.0000 0.0000 Eu-154 1.39E+07 B1-010-04A-CJFC-013-CV
-1.14E+03 0.00E+00 0.0000 0.0000 Eu-155 5.77E+08 B1-010-04A-CJFC-013-CV 2.59E+03 2.59E+03 0.0000 0.0001 Np-237 1.51E+05 B1-010-04A-CJFC-013-CV
-1.86E+03 0.00E+00 0.0000 0.0000 Pu-238 1.77E+07 B1-010-04A-CJFC-013-CV 5.16E+03 5.16E+03 0.0003 0.0073 Pu-239 1.46E+07 B1-010-04A-CJFC-013-CV 2.52E+03 2.52E+03 0.0002 0.0043 Pu-240 1.46E+07 B1-010-04A-CJFC-013-CV 2.52E+03 2.52E+03 0.0002 0.0043 Pu-241 7.81E+08 B1-010-04A-CJFC-013-CV 1.31E+05 1.31E+05 0.0002 0.0042 Am-241 2.75E+07 B1-010-04A-CJFC-013-CV 1.50E+04 1.50E+04 0.0005 0.0137 Am-243 2.16E+07 B1-010-04A-CJFC-013-CV
-3.16E+02 0.00E+00 0.0000 0.0000 Cm-243 6.66E+07 B1-010-04A-CJFC-013-CV
-7.66E+01 0.00E+00 0.0000 0.0000 Cm-244 1.34E+08 B1-010-04A-CJFC-013-CV
-7.66E+01 0.00E+00 0.0000 0.0000 0.0344 H-3 5.91E+09 B1-010-04A-CJFC-014-CV 1.53E+05 1.53E+05 0.0000 0.0006 C-14 5.33E+08 B1-010-04A-CJFC-014-CV
-4.23E+02 0.00E+00 0.0000 0.0000 Fe-55 2.32E+10 B1-010-04A-CJFC-014-CV
-1.44E+05 0.00E+00 0.0000 0.0000 Ni-59 2.09E+11 B1-010-04A-CJFC-014-CV 7.54E+03 7.54E+03 0.0000 0.0000 Co-60 6.42E+06 B1-010-04A-CJFC-014-CV 7.33E+03 7.33E+03 0.0011 0.0285 Ni-63 8.49E+10 B1-010-04A-CJFC-014-CV 3.19E+05 3.19E+05 0.0000 0.0001 Sr-90 1.18E+07 B1-010-04A-CJFC-014-CV 3.25E+03 3.25E+03 0.0003 0.0069 Nb-94 1.05E+07 B1-010-04A-CJFC-014-CV
-1.13E+02 0.00E+00 0.0000 0.0000 Tc-99 1.50E+08 B1-010-04A-CJFC-014-CV 8.52E+04 8.52E+04 0.0006 0.0142 Cs-137 2.82E+07 B1-010-04A-CJFC-014-CV 4.08E+06 4.08E+06 0.1448 3.6193 Eu-152 1.51E+07 B1-010-04A-CJFC-014-CV 9.92E+03 9.92E+03 0.0007 0.0164 Eu-154 1.39E+07 B1-010-04A-CJFC-014-CV
-3.01E+03 0.00E+00 0.0000 0.0000 Eu-155 5.77E+08 B1-010-04A-CJFC-014-CV 2.24E+03 2.24E+03 0.0000 0.0001 Np-237 1.51E+05 B1-010-04A-CJFC-014-CV
-2.85E+02 0.00E+00 0.0000 0.0000 Pu-238 1.77E+07 B1-010-04A-CJFC-014-CV 6.94E+03 6.94E+03 0.0004 0.0098 Pu-239 1.46E+07 B1-010-04A-CJFC-014-CV 8.05E+03 8.05E+03 0.0006 0.0138 Pu-240 1.46E+07 B1-010-04A-CJFC-014-CV 8.05E+03 8.05E+03 0.0006 0.0138 Pu-241 7.81E+08 B1-010-04A-CJFC-014-CV 1.67E+05 1.67E+05 0.0002 0.0053 Am-241 2.75E+07 B1-010-04A-CJFC-014-CV 2.04E+04 2.04E+04 0.0007 0.0185 Am-243 2.16E+07 B1-010-04A-CJFC-014-CV 3.78E+02 3.78E+02 0.0000 0.0004 Cm-243 6.66E+07 B1-010-04A-CJFC-014-CV 3.87E+02 3.87E+02 0.0000 0.0001 Cm-244 1.34E+08 B1-010-04A-CJFC-014-CV 3.87E+02 3.87E+02 0.0000 0.0001 0.0769 H-3 5.91E+09 B1-010-04A-CJFC-015-CV 1.11E+05 1.11E+05 0.0000 0.0005 C-14 5.33E+08 B1-010-04A-CJFC-015-CV 3.28E+04 3.28E+04 0.0001 0.0015 Fe-55 2.32E+10 B1-010-04A-CJFC-015-CV 5.87E+04 5.87E+04 0.0000 0.0001 Ni-59 2.09E+11 B1-010-04A-CJFC-015-CV
-8.91E+03 0.00E+00 0.0000 0.0000 Co-60 6.42E+06 B1-010-04A-CJFC-015-CV
-1.20E+03 0.00E+00 0.0000 0.0000 Ni-63 8.49E+10 B1-010-04A-CJFC-015-CV 4.26E+04 4.26E+04 0.0000 0.0000 Sr-90 1.18E+07 B1-010-04A-CJFC-015-CV
-6.47E+03 0.00E+00 0.0000 0.0000 Nb-94 1.05E+07 B1-010-04A-CJFC-015-CV 1.09E+03 1.09E+03 0.0001 0.0026 Tc-99 1.50E+08 B1-010-04A-CJFC-015-CV
-1.58E+04 0.00E+00 0.0000 0.0000 Cs-137 2.82E+07 B1-010-04A-CJFC-015-CV
-2.15E+02 0.00E+00 0.0000 0.0000 Eu-152 1.51E+07 B1-010-04A-CJFC-015-CV 4.86E+02 4.86E+02 0.0000 0.0008 Eu-154 1.39E+07 B1-010-04A-CJFC-015-CV
-1.86E+03 0.00E+00 0.0000 0.0000 Eu-155 5.77E+08 B1-010-04A-CJFC-015-CV 5.07E+03 5.07E+03 0.0000 0.0002 Np-237 1.51E+05 B1-010-04A-CJFC-015-CV 5.45E+02 5.45E+02 0.0036 0.0903 Pu-238 1.77E+07 B1-010-04A-CJFC-015-CV 6.44E+01 6.44E+01 0.0000 0.0001 Pu-239 1.46E+07 B1-010-04A-CJFC-015-CV 6.17E+02 6.17E+02 0.0000 0.0011 Pu-240 1.46E+07 B1-010-04A-CJFC-015-CV 6.17E+02 6.17E+02 0.0000 0.0011 Pu-241 7.81E+08 B1-010-04A-CJFC-015-CV 1.26E+04 1.26E+04 0.0000 0.0004 Am-241 2.75E+07 B1-010-04A-CJFC-015-CV 1.53E+02 1.53E+02 0.0000 0.0001 Am-243 2.16E+07 B1-010-04A-CJFC-015-CV 1.30E+02 1.30E+02 0.0000 0.0002 Cm-243 6.66E+07 B1-010-04A-CJFC-015-CV 1.52E+02 1.52E+02 0.0000 0.0001 Cm-244 1.34E+08 B1-010-04A-CJFC-015-CV 1.52E+02 1.52E+02 0.0000 0.0000 0.0982 H-3 5.91E+09 B1-010-04A-CJFC-016-CV 1.17E+05 1.17E+05 0.0000 0.0005 C-14 5.33E+08 B1-010-04A-CJFC-016-CV 1.56E+04 1.56E+04 0.0000 0.0007 Fe-55 2.32E+10 B1-010-04A-CJFC-016-CV
-1.25E+05 0.00E+00 0.0000 0.0000 Ni-59 2.09E+11 B1-010-04A-CJFC-016-CV 1.52E+04 1.52E+04 0.0000 0.0000 Co-60 6.42E+06 B1-010-04A-CJFC-016-CV 2.07E+03 2.07E+03 0.0003 0.0080 Ni-63 8.49E+10 B1-010-04A-CJFC-016-CV 3.96E+04 3.96E+04 0.0000 0.0000 Sr-90 1.18E+07 B1-010-04A-CJFC-016-CV
-1.27E+03 0.00E+00 0.0000 0.0000 Nb-94 1.05E+07 B1-010-04A-CJFC-016-CV 3.01E+02 3.01E+02 0.0000 0.0007 Tc-99 1.50E+08 B1-010-04A-CJFC-016-CV
-1.64E+03 0.00E+00 0.0000 0.0000 Cs-137 2.82E+07 B1-010-04A-CJFC-016-CV 1.98E+05 1.98E+05 0.0070 0.1754 Eu-152 1.51E+07 B1-010-04A-CJFC-016-CV 3.22E+03 3.22E+03 0.0002 0.0053 Eu-154 1.39E+07 B1-010-04A-CJFC-016-CV 3.34E+03 3.34E+03 0.0002 0.0060 Eu-155 5.77E+08 B1-010-04A-CJFC-016-CV
-2.57E+03 0.00E+00 0.0000 0.0000 Np-237 1.51E+05 B1-010-04A-CJFC-016-CV 2.58E+02 2.58E+02 0.0017 0.0427 Pu-238 1.77E+07 B1-010-04A-CJFC-016-CV 5.33E+02 5.33E+02 0.0000 0.0008 Pu-239 1.46E+07 B1-010-04A-CJFC-016-CV
-4.71E+01 0.00E+00 0.0000 0.0000 Pu-240 1.46E+07 B1-010-04A-CJFC-016-CV
-4.71E+01 0.00E+00 0.0000 0.0000 Pu-241 7.81E+08 B1-010-04A-CJFC-016-CV 2.06E+04 2.06E+04 0.0000 0.0007 Am-241 2.75E+07 B1-010-04A-CJFC-016-CV 1.55E+03 1.55E+03 0.0001 0.0014 Am-243 2.16E+07 B1-010-04A-CJFC-016-CV 1.51E+01 1.51E+01 0.0000 0.0000 Cm-243 6.66E+07 B1-010-04A-CJFC-016-CV
-1.01E+02 0.00E+00 0.0000 0.0000 Cm-244 1.34E+08 B1-010-04A-CJFC-016-CV
-1.01E+02 0.00E+00 0.0000 0.0000 0.0475 H-3 1.75E+04 B1-010-04A-CJFS-001-SB 3.68E+00 3.68E+00 0.0002 0.0053 C-14 2.45E+05 B1-010-04A-CJFS-001-SB 5.87E-02 5.87E-02 0.0000 0.0000 Fe-55 1.02E+07 B1-010-04A-CJFS-001-SB
-1.34E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-04A-CJFS-001-SB 0.00E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-04A-CJFS-001-SB
-1.76E-03 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 B1-010-04A-CJFS-001-SB 4.38E-01 4.38E-01 0.0000 0.0000 Sr-90 6.59E+03 B1-010-04A-CJFS-001-SB 1.78E-01 1.78E-01 0.0000 0.0007 Nb-94 2.02E+01 B1-010-04A-CJFS-001-SB
-2.49E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 B1-010-04A-CJFS-001-SB 4.83E-01 4.83E-01 0.0014 0.0339 Cs-137 5.81E+01 B1-010-04A-CJFS-001-SB 1.88E-02 1.88E-02 0.0003 0.0081 Eu-152 2.84E+01 B1-010-04A-CJFS-001-SB
-2.59E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 B1-010-04A-CJFS-001-SB 2.14E-02 2.14E-02 0.0008 0.0203 Eu-155 1.12E+03 B1-010-04A-CJFS-001-SB 1.78E-02 1.78E-02 0.0000 0.0004 Np-237 7.99E-01 B1-010-04A-CJFS-001-SB 1.37E-03 1.37E-03 0.0017 0.0429 Pu-238 1.66E+03 B1-010-04A-CJFS-001-SB
-1.60E-02 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 B1-010-04A-CJFS-001-SB
-1.08E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 B1-010-04A-CJFS-001-SB
-1.08E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 B1-010-04A-CJFS-001-SB 1.03E+00 1.03E+00 0.0000 0.0007
Am-241 1.09E+03 B1-010-04A-CJFS-001-SB 0.00E+00 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 B1-010-04A-CJFS-001-SB
-5.65E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 B1-010-04A-CJFS-001-SB
-1.64E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 B1-010-04A-CJFS-001-SB
-1.64E-03 0.00E+00 0.0000 0.0000 0.0831 H-3 1.75E+04 B1-010-04A-CJFS-002-SB 1.44E+00 1.44E+00 0.0001 0.0021 C-14 2.45E+05 B1-010-04A-CJFS-002-SB 7.86E-01 7.86E-01 0.0000 0.0001 Fe-55 1.02E+07 B1-010-04A-CJFS-002-SB
-3.55E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-04A-CJFS-002-SB
-5.94E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-04A-CJFS-002-SB 3.68E-03 3.68E-03 0.0003 0.0072 Ni-63 9.48E+06 B1-010-04A-CJFS-002-SB 1.34E+00 1.34E+00 0.0000 0.0000 Sr-90 6.59E+03 B1-010-04A-CJFS-002-SB 2.05E-01 2.05E-01 0.0000 0.0008 Nb-94 2.02E+01 B1-010-04A-CJFS-002-SB 1.19E-02 1.19E-02 0.0006 0.0147 Tc-99 3.56E+02 B1-010-04A-CJFS-002-SB
-8.06E-02 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 B1-010-04A-CJFS-002-SB 4.96E-03 4.96E-03 0.0001 0.0021 Eu-152 2.84E+01 B1-010-04A-CJFS-002-SB
-1.69E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 B1-010-04A-CJFS-002-SB
-6.84E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 B1-010-04A-CJFS-002-SB 1.74E-02 1.74E-02 0.0000 0.0004 Np-237 7.99E-01 B1-010-04A-CJFS-002-SB 1.72E-03 1.72E-03 0.0022 0.0538 Pu-238 1.66E+03 B1-010-04A-CJFS-002-SB 2.54E-02 2.54E-02 0.0000 0.0004 Pu-239 1.49E+03 B1-010-04A-CJFS-002-SB 5.77E-03 5.77E-03 0.0000 0.0001 Pu-240 1.50E+03 B1-010-04A-CJFS-002-SB 5.77E-03 5.77E-03 0.0000 0.0001 Pu-241 3.64E+04 B1-010-04A-CJFS-002-SB 9.60E-01 9.60E-01 0.0000 0.0007 Am-241 1.09E+03 B1-010-04A-CJFS-002-SB 4.10E-02 4.10E-02 0.0000 0.0009 Am-243 1.87E+02 B1-010-04A-CJFS-002-SB 4.28E-04 4.28E-04 0.0000 0.0001 Cm-243 2.88E+02 B1-010-04A-CJFS-002-SB 4.66E-03 4.66E-03 0.0000 0.0004 Cm-244 2.67E+03 B1-010-04A-CJFS-002-SB 4.66E-03 4.66E-03 0.0000 0.0000 0.0738 H-3 1.75E+04 B1-010-04A-CJFS-003-SB 1.26E+01 1.26E+01 0.0007 0.0180 C-14 2.45E+05 B1-010-04A-CJFS-003-SB 7.37E-01 7.37E-01 0.0000 0.0001 Fe-55 1.02E+07 B1-010-04A-CJFS-003-SB
-1.30E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-04A-CJFS-003-SB
-8.05E-02 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-04A-CJFS-003-SB
-1.71E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 B1-010-04A-CJFS-003-SB 3.32E-01 3.32E-01 0.0000 0.0000 Sr-90 6.59E+03 B1-010-04A-CJFS-003-SB 2.99E-01 2.99E-01 0.0000 0.0011 Nb-94 2.02E+01 B1-010-04A-CJFS-003-SB 8.31E-03 8.31E-03 0.0004 0.0103 Tc-99 3.56E+02 B1-010-04A-CJFS-003-SB 2.56E-01 2.56E-01 0.0007 0.0180 Cs-137 5.81E+01 B1-010-04A-CJFS-003-SB
-2.21E-03 0.00E+00 0.0000 0.0000 Eu-152 2.84E+01 B1-010-04A-CJFS-003-SB 5.48E-02 5.48E-02 0.0019 0.0482 Eu-154 2.64E+01 B1-010-04A-CJFS-003-SB 4.50E-02 4.50E-02 0.0017 0.0427 Eu-155 1.12E+03 B1-010-04A-CJFS-003-SB
-1.57E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 B1-010-04A-CJFS-003-SB
-1.25E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 B1-010-04A-CJFS-003-SB
-5.73E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 B1-010-04A-CJFS-003-SB
-1.04E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 B1-010-04A-CJFS-003-SB
-1.04E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 B1-010-04A-CJFS-003-SB 1.22E+00 1.22E+00 0.0000 0.0008 Am-241 1.09E+03 B1-010-04A-CJFS-003-SB 1.06E-02 1.06E-02 0.0000 0.0002 Am-243 1.87E+02 B1-010-04A-CJFS-003-SB 1.32E-02 1.32E-02 0.0001 0.0018 Cm-243 2.88E+02 B1-010-04A-CJFS-003-SB
-9.38E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 B1-010-04A-CJFS-003-SB
-9.38E-03 0.00E+00 0.0000 0.0000 0.0492 H-3 1.75E+04 B1-010-04A-CJFS-004-SB 3.54E+00 3.54E+00 0.0002 0.0051 C-14 2.45E+05 B1-010-04A-CJFS-004-SB 9.13E-01 9.13E-01 0.0000 0.0001 Fe-55 1.02E+07 B1-010-04A-CJFS-004-SB
-1.12E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-04A-CJFS-004-SB 6.67E-01 6.67E-01 0.0000 0.0000 Co-60 1.28E+01 B1-010-04A-CJFS-004-SB
-1.03E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 B1-010-04A-CJFS-004-SB 8.61E-01 8.61E-01 0.0000 0.0000 Sr-90 6.59E+03 B1-010-04A-CJFS-004-SB 1.20E-01 1.20E-01 0.0000 0.0005 Nb-94 2.02E+01 B1-010-04A-CJFS-004-SB 2.68E-03 2.68E-03 0.0001 0.0033 Tc-99 3.56E+02 B1-010-04A-CJFS-004-SB 8.45E-01 8.45E-01 0.0024 0.0593 Cs-137 5.81E+01 B1-010-04A-CJFS-004-SB 9.21E-03 9.21E-03 0.0002 0.0040 Eu-152 2.84E+01 B1-010-04A-CJFS-004-SB
-3.22E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 B1-010-04A-CJFS-004-SB 8.23E-03 8.23E-03 0.0003 0.0078 Eu-155 1.12E+03 B1-010-04A-CJFS-004-SB
-4.45E-03 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 B1-010-04A-CJFS-004-SB 2.39E-03 2.39E-03 0.0030 0.0748 Pu-238 1.66E+03 B1-010-04A-CJFS-004-SB 2.25E-04 2.25E-04 0.0000 0.0000 Pu-239 1.49E+03 B1-010-04A-CJFS-004-SB
-2.13E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 B1-010-04A-CJFS-004-SB
-2.13E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 B1-010-04A-CJFS-004-SB
-2.75E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 B1-010-04A-CJFS-004-SB 1.33E-02 1.33E-02 0.0000 0.0003 Am-243 1.87E+02 B1-010-04A-CJFS-004-SB 6.62E-03 6.62E-03 0.0000 0.0009 Cm-243 2.88E+02 B1-010-04A-CJFS-004-SB
-6.06E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 B1-010-04A-CJFS-004-SB
-6.06E-03 0.00E+00 0.0000 0.0000 0.1437 H-3 1.75E+04 B1-010-04A-QJWS-008-SB
-1.57E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 B1-010-04A-QJWS-008-SB 1.12E+00 1.12E+00 0.0000 0.0001 Fe-55 1.02E+07 B1-010-04A-QJWS-008-SB
-2.54E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-04A-QJWS-008-SB
-3.06E-02 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-04A-QJWS-008-SB 2.26E-02 2.26E-02 0.0018 0.0441 Ni-63 9.48E+06 B1-010-04A-QJWS-008-SB 1.06E+00 1.06E+00 0.0000 0.0000 Sr-90 6.59E+03 B1-010-04A-QJWS-008-SB 1.36E-01 1.36E-01 0.0000 0.0005 Nb-94 2.02E+01 B1-010-04A-QJWS-008-SB 3.45E-03 3.45E-03 0.0002 0.0043 Tc-99 3.56E+02 B1-010-04A-QJWS-008-SB 3.87E-01 3.87E-01 0.0011 0.0272 Cs-137 5.81E+01 B1-010-04A-QJWS-008-SB 1.17E-01 1.17E-01 0.0020 0.0503 Eu-152 2.84E+01 B1-010-04A-QJWS-008-SB
-3.38E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 B1-010-04A-QJWS-008-SB
-4.01E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 B1-010-04A-QJWS-008-SB
-4.73E-03 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 B1-010-04A-QJWS-008-SB
-5.85E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 B1-010-04A-QJWS-008-SB
-1.28E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 B1-010-04A-QJWS-008-SB
-7.44E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 B1-010-04A-QJWS-008-SB
-7.44E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 B1-010-04A-QJWS-008-SB 3.90E-01 3.90E-01 0.0000 0.0003 Am-241 1.09E+03 B1-010-04A-QJWS-008-SB 4.43E-03 4.43E-03 0.0000 0.0001 Am-243 1.87E+02 B1-010-04A-QJWS-008-SB
-4.37E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 B1-010-04A-QJWS-008-SB 0.00E+00 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 B1-010-04A-QJWS-008-SB 0.00E+00 0.00E+00 0.0000 0.0000 0.0319 H-3 1.75E+04 B1-010-04A-CJWS-005-SB 2.04E+00 2.04E+00 0.0001 0.0029 C-14 2.45E+05 B1-010-04A-CJWS-005-SB 1.38E+00 1.38E+00 0.0000 0.0001 Fe-55 1.02E+07 B1-010-04A-CJWS-005-SB
-1.84E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-04A-CJWS-005-SB
-4.43E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-04A-CJWS-005-SB
-1.73E-04 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 B1-010-04A-CJWS-005-SB 1.29E-01 1.29E-01 0.0000 0.0000 Sr-90 6.59E+03 B1-010-04A-CJWS-005-SB
-7.34E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 B1-010-04A-CJWS-005-SB
-4.39E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 B1-010-04A-CJWS-005-SB 2.17E-01 2.17E-01 0.0006 0.0152 Cs-137 5.81E+01 B1-010-04A-CJWS-005-SB 1.08E-01 1.08E-01 0.0019 0.0465 Eu-152 2.84E+01 B1-010-04A-CJWS-005-SB 3.55E-02 3.55E-02 0.0012 0.0312 Eu-154 2.64E+01 B1-010-04A-CJWS-005-SB 3.49E-02 3.49E-02 0.0013 0.0331 Eu-155 1.12E+03 B1-010-04A-CJWS-005-SB
-7.90E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 B1-010-04A-CJWS-005-SB
-1.74E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 B1-010-04A-CJWS-005-SB 5.64E-03 5.64E-03 0.0000 0.0001 Pu-239 1.49E+03 B1-010-04A-CJWS-005-SB 4.51E-03 4.51E-03 0.0000 0.0001 Pu-240 1.50E+03 B1-010-04A-CJWS-005-SB 4.51E-03 4.51E-03 0.0000 0.0001 Pu-241 3.64E+04 B1-010-04A-CJWS-005-SB 1.97E+00 1.97E+00 0.0001 0.0014 Am-241 1.09E+03 B1-010-04A-CJWS-005-SB
-3.09E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 B1-010-04A-CJWS-005-SB 1.35E-03 1.35E-03 0.0000 0.0002 Cm-243 2.88E+02 B1-010-04A-CJWS-005-SB 4.84E-03 4.84E-03 0.0000 0.0004 Cm-244 2.67E+03 B1-010-04A-CJWS-005-SB 4.84E-03 4.84E-03 0.0000 0.0000 0.0205 H-3 1.75E+04 B1-010-04A-CJWS-006-SB 2.54E+00 2.54E+00 0.0001 0.0036 C-14 2.45E+05 B1-010-04A-CJWS-006-SB 1.31E+00 1.31E+00 0.0000 0.0001 Fe-55 1.02E+07 B1-010-04A-CJWS-006-SB
-2.99E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-04A-CJWS-006-SB
-1.40E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-04A-CJWS-006-SB 4.78E-03 4.78E-03 0.0004 0.0093 Ni-63 9.48E+06 B1-010-04A-CJWS-006-SB 5.74E-02 5.74E-02 0.0000 0.0000 Sr-90 6.59E+03 B1-010-04A-CJWS-006-SB
-8.75E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 B1-010-04A-CJWS-006-SB 5.81E-03 5.81E-03 0.0003 0.0072 Tc-99 3.56E+02 B1-010-04A-CJWS-006-SB 7.91E-01 7.91E-01 0.0022 0.0555 Cs-137 5.81E+01 B1-010-04A-CJWS-006-SB 3.44E-02 3.44E-02 0.0006 0.0148 Eu-152 2.84E+01 B1-010-04A-CJWS-006-SB
-1.86E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 B1-010-04A-CJWS-006-SB
-2.92E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 B1-010-04A-CJWS-006-SB 6.39E-03 6.39E-03 0.0000 0.0001 Np-237 7.99E-01 B1-010-04A-CJWS-006-SB
-1.52E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 B1-010-04A-CJWS-006-SB 6.60E-03 6.60E-03 0.0000 0.0001 Pu-239 1.49E+03 B1-010-04A-CJWS-006-SB
-7.42E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 B1-010-04A-CJWS-006-SB
-7.42E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 B1-010-04A-CJWS-006-SB 1.49E-01 1.49E-01 0.0000 0.0001 Am-241 1.09E+03 B1-010-04A-CJWS-006-SB
-4.32E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 B1-010-04A-CJWS-006-SB
-7.58E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 B1-010-04A-CJWS-006-SB 2.37E-04 2.37E-04 0.0000 0.0000 Cm-244 2.67E+03 B1-010-04A-CJWS-006-SB 2.37E-04 2.37E-04 0.0000 0.0000 0.0668 H-3 1.75E+04 B1-010-04A-CJWS-007-SB 4.33E+00 4.33E+00 0.0002 0.0062 C-14 2.45E+05 B1-010-04A-CJWS-007-SB
-9.34E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 B1-010-04A-CJWS-007-SB
-1.67E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-04A-CJWS-007-SB
-1.23E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-04A-CJWS-007-SB 1.35E-02 1.35E-02 0.0011 0.0263 Ni-63 9.48E+06 B1-010-04A-CJWS-007-SB 1.25E+00 1.25E+00 0.0000 0.0000 Sr-90 6.59E+03 B1-010-04A-CJWS-007-SB 2.10E-01 2.10E-01 0.0000 0.0008 Nb-94 2.02E+01 B1-010-04A-CJWS-007-SB 2.26E-02 2.26E-02 0.0011 0.0280 Tc-99 3.56E+02 B1-010-04A-CJWS-007-SB 1.04E+00 1.04E+00 0.0029 0.0730 Cs-137 5.81E+01 B1-010-04A-CJWS-007-SB 7.61E-02 7.61E-02 0.0013 0.0327 Eu-152 2.84E+01 B1-010-04A-CJWS-007-SB 1.24E-02 1.24E-02 0.0004 0.0109 Eu-154 2.64E+01 B1-010-04A-CJWS-007-SB 1.83E-02 1.83E-02 0.0007 0.0174 Eu-155 1.12E+03 B1-010-04A-CJWS-007-SB 5.51E-03 5.51E-03 0.0000 0.0001 Np-237 7.99E-01 B1-010-04A-CJWS-007-SB
-1.89E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 B1-010-04A-CJWS-007-SB
-4.14E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 B1-010-04A-CJWS-007-SB
-1.02E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 B1-010-04A-CJWS-007-SB
-1.02E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 B1-010-04A-CJWS-007-SB 1.39E+00 1.39E+00 0.0000 0.0010 Am-241 1.09E+03 B1-010-04A-CJWS-007-SB
-5.22E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 B1-010-04A-CJWS-007-SB
-3.63E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 B1-010-04A-CJWS-007-SB 1.52E-02 1.52E-02 0.0001 0.0013 Cm-244 2.67E+03 B1-010-04A-CJWS-007-SB 1.52E-02 1.52E-02 0.0000 0.0001 0.1097 H-3 1.75E+04 B1-010-04A-CJWS-008-SB
-3.74E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 B1-010-04A-CJWS-008-SB 8.96E-01 8.96E-01 0.0000 0.0001 Fe-55 1.02E+07 B1-010-04A-CJWS-008-SB
-2.96E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 B1-010-04A-CJWS-008-SB
-7.81E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 B1-010-04A-CJWS-008-SB
-5.94E-03 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 B1-010-04A-CJWS-008-SB 9.73E-01 9.73E-01 0.0000 0.0000 Sr-90 6.59E+03 B1-010-04A-CJWS-008-SB
-2.39E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 B1-010-04A-CJWS-008-SB
-1.05E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 B1-010-04A-CJWS-008-SB 1.03E+00 1.03E+00 0.0029 0.0723 Cs-137 5.81E+01 B1-010-04A-CJWS-008-SB 1.00E-01 1.00E-01 0.0017 0.0430 Eu-152 2.84E+01 B1-010-04A-CJWS-008-SB
-2.98E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 B1-010-04A-CJWS-008-SB 5.70E-02 5.70E-02 0.0022 0.0541 Eu-155 1.12E+03 B1-010-04A-CJWS-008-SB 1.89E-02 1.89E-02 0.0000 0.0004 Np-237 7.99E-01 B1-010-04A-CJWS-008-SB
-6.93E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 B1-010-04A-CJWS-008-SB
-1.46E-02 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 B1-010-04A-CJWS-008-SB
-4.32E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 B1-010-04A-CJWS-008-SB
-4.32E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 B1-010-04A-CJWS-008-SB
-2.37E-02 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 B1-010-04A-CJWS-008-SB
-1.76E-02 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 B1-010-04A-CJWS-008-SB 7.48E-03 7.48E-03 0.0000 0.0010 Cm-243 2.88E+02 B1-010-04A-CJWS-008-SB 0.00E+00 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 B1-010-04A-CJWS-008-SB 0.00E+00 0.00E+00 0.0000 0.0000 0.0738 0.1437
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L1-SUB-TDS-CJGS-A01-SB 4.06E+00 4.06E+00 0.0002 0.0058 C-14 2.45E+05 L1-SUB-TDS-CJGS-A01-SB
-2.58E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-CJGS-A01-SB
-1.70E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-CJGS-A01-SB
-4.64E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-CJGS-A01-SB 9.67E-03 9.67E-03 0.0008 0.0189 Ni-63 9.48E+06 L1-SUB-TDS-CJGS-A01-SB 1.70E+00 1.70E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-CJGS-A01-SB 8.73E-02 8.73E-02 0.0000 0.0003 Nb-94 2.02E+01 L1-SUB-TDS-CJGS-A01-SB 9.99E-03 9.99E-03 0.0005 0.0124 Tc-99 3.56E+02 L1-SUB-TDS-CJGS-A01-SB
-4.50E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-TDS-CJGS-A01-SB 3.12E-01 3.12E-01 0.0054 0.1342 Eu-152 2.84E+01 L1-SUB-TDS-CJGS-A01-SB 3.10E-02 3.10E-02 0.0011 0.0273 Eu-154 2.64E+01 L1-SUB-TDS-CJGS-A01-SB 2.92E-02 2.92E-02 0.0011 0.0277 Eu-155 1.12E+03 L1-SUB-TDS-CJGS-A01-SB 7.49E-03 7.49E-03 0.0000 0.0002 Np-237 7.99E-01 L1-SUB-TDS-CJGS-A01-SB
-4.40E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-SUB-TDS-CJGS-A01-SB 3.50E-03 3.50E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-SUB-TDS-CJGS-A01-SB
-4.81E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-CJGS-A01-SB
-4.81E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-CJGS-A01-SB 3.99E+00 3.99E+00 0.0001 0.0027 Am-241 1.09E+03 L1-SUB-TDS-CJGS-A01-SB 2.33E-02 2.33E-02 0.0000 0.0005 Am-243 1.87E+02 L1-SUB-TDS-CJGS-A01-SB
-1.54E-02 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-SUB-TDS-CJGS-A01-SB
-4.04E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-TDS-CJGS-A01-SB
-4.04E-03 0.00E+00 0.0000 0.0000 0.0217
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L1-SUB-TDS-CJGS-B01-SB 1.66E+00 1.66E+00 0.0001 0.0024 C-14 2.45E+05 L1-SUB-TDS-CJGS-B01-SB
-4.70E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-CJGS-B01-SB
-1.41E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-CJGS-B01-SB 7.09E-02 7.09E-02 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-CJGS-B01-SB 4.59E-03 4.59E-03 0.0004 0.0090 Ni-63 9.48E+06 L1-SUB-TDS-CJGS-B01-SB 4.90E-02 4.90E-02 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-CJGS-B01-SB
-1.41E-01 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-SUB-TDS-CJGS-B01-SB 5.76E-03 5.76E-03 0.0003 0.0071 Tc-99 3.56E+02 L1-SUB-TDS-CJGS-B01-SB
-9.58E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-TDS-CJGS-B01-SB 1.39E-01 1.39E-01 0.0024 0.0598 Eu-152 2.84E+01 L1-SUB-TDS-CJGS-B01-SB
-7.33E-03 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-SUB-TDS-CJGS-B01-SB 5.42E-02 5.42E-02 0.0021 0.0514 Eu-155 1.12E+03 L1-SUB-TDS-CJGS-B01-SB 1.04E-02 1.04E-02 0.0000 0.0002 Np-237 7.99E-01 L1-SUB-TDS-CJGS-B01-SB 2.67E-03 2.67E-03 0.0033 0.0835 Pu-238 1.66E+03 L1-SUB-TDS-CJGS-B01-SB 4.59E-03 4.59E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-SUB-TDS-CJGS-B01-SB 9.94E-04 9.94E-04 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-CJGS-B01-SB 9.94E-04 9.94E-04 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-CJGS-B01-SB 1.88E+00 1.88E+00 0.0001 0.0013 Am-241 1.09E+03 L1-SUB-TDS-CJGS-B01-SB 1.07E-02 1.07E-02 0.0000 0.0002 Am-243 1.87E+02 L1-SUB-TDS-CJGS-B01-SB 5.21E-03 5.21E-03 0.0000 0.0007 Cm-243 2.88E+02 L1-SUB-TDS-CJGS-B01-SB
-2.96E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-TDS-CJGS-B01-SB
-2.96E-03 0.00E+00 0.0000 0.0000 0.0956 H-3 1.75E+04 L1-SUB-TDS-CJGS-B02-SB
-1.54E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-SUB-TDS-CJGS-B02-SB 4.86E-01 4.86E-01 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-CJGS-B02-SB 4.78E-01 4.78E-01 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-CJGS-B02-SB
-1.23E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-CJGS-B02-SB
-4.74E-03 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-SUB-TDS-CJGS-B02-SB 8.93E-01 8.93E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-CJGS-B02-SB 1.24E-01 1.24E-01 0.0000 0.0005 Nb-94 2.02E+01 L1-SUB-TDS-CJGS-B02-SB 1.73E-02 1.73E-02 0.0009 0.0214 Tc-99 3.56E+02 L1-SUB-TDS-CJGS-B02-SB
-6.54E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-TDS-CJGS-B02-SB 4.74E-02 4.74E-02 0.0008 0.0204 Eu-152 2.84E+01 L1-SUB-TDS-CJGS-B02-SB 5.94E-02 5.94E-02 0.0021 0.0522 Eu-154 2.64E+01 L1-SUB-TDS-CJGS-B02-SB
-2.94E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-TDS-CJGS-B02-SB 0.00E+00 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-SUB-TDS-CJGS-B02-SB 2.04E-03 2.04E-03 0.0026 0.0638 Pu-238 1.66E+03 L1-SUB-TDS-CJGS-B02-SB 1.60E-03 1.60E-03 0.0000 0.0000 Pu-239 1.49E+03 L1-SUB-TDS-CJGS-B02-SB 1.67E-02 1.67E-02 0.0000 0.0003 Pu-240 1.50E+03 L1-SUB-TDS-CJGS-B02-SB 1.67E-02 1.67E-02 0.0000 0.0003 Pu-241 3.64E+04 L1-SUB-TDS-CJGS-B02-SB
-2.36E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-CJGS-B02-SB 8.39E-03 8.39E-03 0.0000 0.0002 Am-243 1.87E+02 L1-SUB-TDS-CJGS-B02-SB
-1.90E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-SUB-TDS-CJGS-B02-SB 3.41E-03 3.41E-03 0.0000 0.0003 Cm-244 2.67E+03 L1-SUB-TDS-CJGS-B02-SB 3.41E-03 3.41E-03 0.0000 0.0000 0.0864 H-3 1.75E+04 L1-SUB-TDS-CJGS-B03-SB 3.04E+00 3.04E+00 0.0002 0.0044 C-14 2.45E+05 L1-SUB-TDS-CJGS-B03-SB
-4.72E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-CJGS-B03-SB
-3.76E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-CJGS-B03-SB
-1.07E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-CJGS-B03-SB 4.43E-02 4.43E-02 0.0035 0.0865 Ni-63 9.48E+06 L1-SUB-TDS-CJGS-B03-SB 6.32E-01 6.32E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-CJGS-B03-SB 5.83E-02 5.83E-02 0.0000 0.0002 Nb-94 2.02E+01 L1-SUB-TDS-CJGS-B03-SB
-1.62E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-SUB-TDS-CJGS-B03-SB 1.10E-02 1.10E-02 0.0000 0.0008 Cs-137 5.81E+01 L1-SUB-TDS-CJGS-B03-SB 1.18E+00 1.18E+00 0.0203 0.5076 Eu-152 2.84E+01 L1-SUB-TDS-CJGS-B03-SB 2.33E-02 2.33E-02 0.0008 0.0205 Eu-154 2.64E+01 L1-SUB-TDS-CJGS-B03-SB 1.96E-02 1.96E-02 0.0007 0.0186 Eu-155 1.12E+03 L1-SUB-TDS-CJGS-B03-SB 3.93E-03 3.93E-03 0.0000 0.0001 Np-237 7.99E-01 L1-SUB-TDS-CJGS-B03-SB
-1.33E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-SUB-TDS-CJGS-B03-SB 5.38E-03 5.38E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-SUB-TDS-CJGS-B03-SB 1.05E-02 1.05E-02 0.0000 0.0002 Pu-240 1.50E+03 L1-SUB-TDS-CJGS-B03-SB 1.05E-02 1.05E-02 0.0000 0.0002 Pu-241 3.64E+04 L1-SUB-TDS-CJGS-B03-SB
-2.57E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-CJGS-B03-SB
-1.80E-02 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-SUB-TDS-CJGS-B03-SB
-1.16E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-SUB-TDS-CJGS-B03-SB 1.89E-02 1.89E-02 0.0001 0.0016 Cm-244 2.67E+03 L1-SUB-TDS-CJGS-B03-SB 1.89E-02 1.89E-02 0.0000 0.0002 0.0075 H-3 1.75E+04 L1-SUB-TDS-CJGS-B03A-SB 2.10E-02 2.10E-02 0.0000 0.0000 C-14 2.45E+05 L1-SUB-TDS-CJGS-B03A-SB
-8.60E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-CJGS-B03A-SB 4.95E-01 4.95E-01 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-CJGS-B03A-SB 1.24E+00 1.24E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-CJGS-B03A-SB 1.22E-01 1.22E-01 0.0095 0.2381
Ni-63 9.48E+06 L1-SUB-TDS-CJGS-B03A-SB 3.11E+00 3.11E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-CJGS-B03A-SB
-8.70E-03 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-SUB-TDS-CJGS-B03A-SB 9.39E-04 9.39E-04 0.0000 0.0012 Tc-99 3.56E+02 L1-SUB-TDS-CJGS-B03A-SB
-2.17E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-TDS-CJGS-B03A-SB 4.28E+00 4.28E+00 0.0736 1.8410 Eu-152 2.84E+01 L1-SUB-TDS-CJGS-B03A-SB
-4.18E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-SUB-TDS-CJGS-B03A-SB 2.41E-02 2.41E-02 0.0009 0.0229 Eu-155 1.12E+03 L1-SUB-TDS-CJGS-B03A-SB 1.48E-02 1.48E-02 0.0000 0.0003 Np-237 7.99E-01 L1-SUB-TDS-CJGS-B03A-SB
-2.86E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-SUB-TDS-CJGS-B03A-SB 6.64E-03 6.64E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-SUB-TDS-CJGS-B03A-SB 8.62E-03 8.62E-03 0.0000 0.0001 Pu-240 1.50E+03 L1-SUB-TDS-CJGS-B03A-SB 8.62E-03 8.62E-03 0.0000 0.0001 Pu-241 3.64E+04 L1-SUB-TDS-CJGS-B03A-SB
-1.50E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-TDS-CJGS-B03A-SB 7.09E-02 7.09E-02 0.0001 0.0016 Am-243 1.87E+02 L1-SUB-TDS-CJGS-B03A-SB 5.82E-02 5.82E-02 0.0003 0.0078 Cm-243 2.88E+02 L1-SUB-TDS-CJGS-B03A-SB 2.23E-02 2.23E-02 0.0001 0.0019 Cm-244 2.67E+03 L1-SUB-TDS-CJGS-B03A-SB 2.23E-02 2.23E-02 0.0000 0.0002 0.0135 H-3 1.75E+04 L1-SUB-TDS-CJGS-B04-SB 1.15E+00 1.15E+00 0.0001 0.0016 C-14 2.45E+05 L1-SUB-TDS-CJGS-B04-SB
-5.98E-02 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-CJGS-B04-SB
-2.61E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-CJGS-B04-SB
-1.78E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-CJGS-B04-SB
-2.55E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-SUB-TDS-CJGS-B04-SB
-1.04E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-CJGS-B04-SB
-2.17E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-SUB-TDS-CJGS-B04-SB 1.75E-02 1.75E-02 0.0009 0.0217 Tc-99 3.56E+02 L1-SUB-TDS-CJGS-B04-SB
-1.90E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-TDS-CJGS-B04-SB 9.09E-02 9.09E-02 0.0016 0.0391 Eu-152 2.84E+01 L1-SUB-TDS-CJGS-B04-SB
-1.87E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-SUB-TDS-CJGS-B04-SB 2.38E-02 2.38E-02 0.0009 0.0226 Eu-155 1.12E+03 L1-SUB-TDS-CJGS-B04-SB 2.43E-02 2.43E-02 0.0000 0.0005 Np-237 7.99E-01 L1-SUB-TDS-CJGS-B04-SB 1.59E-03 1.59E-03 0.0020 0.0497 Pu-238 1.66E+03 L1-SUB-TDS-CJGS-B04-SB 1.27E-02 1.27E-02 0.0000 0.0002 Pu-239 1.49E+03 L1-SUB-TDS-CJGS-B04-SB 3.38E-03 3.38E-03 0.0000 0.0001 Pu-240 1.50E+03 L1-SUB-TDS-CJGS-B04-SB 3.38E-03 3.38E-03 0.0000 0.0001 Pu-241 3.64E+04 L1-SUB-TDS-CJGS-B04-SB 5.30E-01 5.30E-01 0.0000 0.0004 Am-241 1.09E+03 L1-SUB-TDS-CJGS-B04-SB 1.23E-02 1.23E-02 0.0000 0.0003 Am-243 1.87E+02 L1-SUB-TDS-CJGS-B04-SB
-4.24E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-SUB-TDS-CJGS-B04-SB 1.07E-02 1.07E-02 0.0000 0.0009 Cm-244 2.67E+03 L1-SUB-TDS-CJGS-B04-SB 1.07E-02 1.07E-02 0.0000 0.0001 0.0756 H-3 1.75E+04 L1-SUB-TDS-CJGS-B05-SB 3.78E-01 3.78E-01 0.0000 0.0005 C-14 2.45E+05 L1-SUB-TDS-CJGS-B05-SB
-2.42E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-CJGS-B05-SB 5.27E-02 5.27E-02 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-CJGS-B05-SB 8.85E-01 8.85E-01 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-CJGS-B05-SB 1.37E-02 1.37E-02 0.0011 0.0267 Ni-63 9.48E+06 L1-SUB-TDS-CJGS-B05-SB 2.54E-01 2.54E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-CJGS-B05-SB 2.19E-02 2.19E-02 0.0000 0.0001 Nb-94 2.02E+01 L1-SUB-TDS-CJGS-B05-SB 1.05E-02 1.05E-02 0.0005 0.0130 Tc-99 3.56E+02 L1-SUB-TDS-CJGS-B05-SB
-6.40E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-TDS-CJGS-B05-SB 6.15E-01 6.15E-01 0.0106 0.2645 Eu-152 2.84E+01 L1-SUB-TDS-CJGS-B05-SB
-2.22E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-SUB-TDS-CJGS-B05-SB
-2.65E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-TDS-CJGS-B05-SB 4.41E-02 4.41E-02 0.0000 0.0010 Np-237 7.99E-01 L1-SUB-TDS-CJGS-B05-SB 9.37E-04 9.37E-04 0.0012 0.0293 Pu-238 1.66E+03 L1-SUB-TDS-CJGS-B05-SB 5.09E-03 5.09E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-SUB-TDS-CJGS-B05-SB 1.48E-02 1.48E-02 0.0000 0.0002
Pu-240 1.50E+03 L1-SUB-TDS-CJGS-B05-SB 1.48E-02 1.48E-02 0.0000 0.0002 Pu-241 3.64E+04 L1-SUB-TDS-CJGS-B05-SB 1.65E+00 1.65E+00 0.0000 0.0011 Am-241 1.09E+03 L1-SUB-TDS-CJGS-B05-SB 3.49E-02 3.49E-02 0.0000 0.0008 Am-243 1.87E+02 L1-SUB-TDS-CJGS-B05-SB 7.42E-04 7.42E-04 0.0000 0.0001 Cm-243 2.88E+02 L1-SUB-TDS-CJGS-B05-SB
-8.49E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-TDS-CJGS-B05-SB
-8.49E-03 0.00E+00 0.0000 0.0000 0.0465 H-3 1.75E+04 L1-SUB-TDS-CJGS-B06A-SB
-2.13E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-SUB-TDS-CJGS-B06A-SB
-1.75E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-TDS-CJGS-B06A-SB 1.07E+00 1.07E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-CJGS-B06A-SB 1.15E+00 1.15E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-CJGS-B06A-SB 5.40E-02 5.40E-02 0.0042 0.1054 Ni-63 9.48E+06 L1-SUB-TDS-CJGS-B06A-SB 6.93E-01 6.93E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-CJGS-B06A-SB
-2.94E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-SUB-TDS-CJGS-B06A-SB 7.44E-03 7.44E-03 0.0004 0.0092 Tc-99 3.56E+02 L1-SUB-TDS-CJGS-B06A-SB
-3.81E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-TDS-CJGS-B06A-SB 1.71E+00 1.71E+00 0.0294 0.7355 Eu-152 2.84E+01 L1-SUB-TDS-CJGS-B06A-SB 3.57E-02 3.57E-02 0.0013 0.0314 Eu-154 2.64E+01 L1-SUB-TDS-CJGS-B06A-SB 2.29E-02 2.29E-02 0.0009 0.0217 Eu-155 1.12E+03 L1-SUB-TDS-CJGS-B06A-SB
-4.28E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-SUB-TDS-CJGS-B06A-SB
-2.85E-05 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-SUB-TDS-CJGS-B06A-SB 4.16E-03 4.16E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-SUB-TDS-CJGS-B06A-SB
-8.02E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-CJGS-B06A-SB
-8.02E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-CJGS-B06A-SB 8.27E-01 8.27E-01 0.0000 0.0006 Am-241 1.09E+03 L1-SUB-TDS-CJGS-B06A-SB 2.32E-02 2.32E-02 0.0000 0.0005 Am-243 1.87E+02 L1-SUB-TDS-CJGS-B06A-SB
-5.50E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-SUB-TDS-CJGS-B06A-SB
-1.12E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-TDS-CJGS-B06A-SB
-1.12E-03 0.00E+00 0.0000 0.0000 0.0104 H-3 1.75E+04 L1-SUB-TDS-CJGS-B07-SB 2.66E+00 2.66E+00 0.0002 0.0038 C-14 2.45E+05 L1-SUB-TDS-CJGS-B07-SB 1.05E+00 1.05E+00 0.0000 0.0001 Fe-55 1.02E+07 L1-SUB-TDS-CJGS-B07-SB
-3.44E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-TDS-CJGS-B07-SB 5.02E-01 5.02E-01 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-TDS-CJGS-B07-SB 2.62E-02 2.62E-02 0.0020 0.0511 Ni-63 9.48E+06 L1-SUB-TDS-CJGS-B07-SB 6.78E-01 6.78E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-TDS-CJGS-B07-SB 2.46E-02 2.46E-02 0.0000 0.0001 Nb-94 2.02E+01 L1-SUB-TDS-CJGS-B07-SB 7.37E-03 7.37E-03 0.0004 0.0091 Tc-99 3.56E+02 L1-SUB-TDS-CJGS-B07-SB
-7.45E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-TDS-CJGS-B07-SB 1.86E+00 1.86E+00 0.0320 0.8001 Eu-152 2.84E+01 L1-SUB-TDS-CJGS-B07-SB 3.25E-02 3.25E-02 0.0011 0.0286 Eu-154 2.64E+01 L1-SUB-TDS-CJGS-B07-SB
-7.25E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-TDS-CJGS-B07-SB 1.02E-02 1.02E-02 0.0000 0.0002 Np-237 7.99E-01 L1-SUB-TDS-CJGS-B07-SB 1.51E-03 1.51E-03 0.0019 0.0472 Pu-238 1.66E+03 L1-SUB-TDS-CJGS-B07-SB 1.27E-02 1.27E-02 0.0000 0.0002 Pu-239 1.49E+03 L1-SUB-TDS-CJGS-B07-SB
-2.82E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-TDS-CJGS-B07-SB
-2.82E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-TDS-CJGS-B07-SB 5.09E-01 5.09E-01 0.0000 0.0003 Am-241 1.09E+03 L1-SUB-TDS-CJGS-B07-SB 3.51E-04 3.51E-04 0.0000 0.0000 Am-243 1.87E+02 L1-SUB-TDS-CJGS-B07-SB 3.05E-03 3.05E-03 0.0000 0.0004 Cm-243 2.88E+02 L1-SUB-TDS-CJGS-B07-SB 1.38E-02 1.38E-02 0.0000 0.0012 Cm-244 2.67E+03 L1-SUB-TDS-CJGS-B07-SB 1.38E-02 1.38E-02 0.0000 0.0001 0.0628 H-3 1.75E+04 Sump #1 2.46E+00 2.46E+00 0.0001 0.0035 C-14 2.45E+05 Sump #1 4.46E-01 4.46E-01 0.0000 0.0000 Fe-55 1.02E+07 Sump #1
-2.63E-01 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 Sump #1 1.70E+00 1.70E+00 0.0000 0.0000 Co-60 1.28E+01 Sump #1 1.23E+01 1.23E+01 0.9602 24.0047 Ni-63 9.48E+06 Sump #1 1.83E+02 1.83E+02 0.0000 0.0005 Sr-90 6.59E+03 Sump #1 4.24E+00 4.24E+00 0.0006 0.0161 Nb-94 2.02E+01 Sump #1 1.58E-03 1.58E-03 0.0001 0.0020 Tc-99 3.56E+02 Sump #1 2.33E+00 2.33E+00 0.0065 0.1635 Cs-137 5.81E+01 Sump #1 1.93E+02 1.93E+02 3.3207 83.0179 Eu-152 2.84E+01 Sump #1
-3.71E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 Sump #1 5.57E-01 5.57E-01 0.0211 0.5283 Eu-155 1.12E+03 Sump #1 9.95E-02 9.95E-02 0.0001 0.0022 Np-237 7.99E-01 Sump #1
-4.43E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 Sump #1 2.55E+00 2.55E+00 0.0015 0.0384 Pu-239 1.49E+03 Sump #1 2.73E+00 2.73E+00 0.0018 0.0457 Pu-240 1.50E+03 Sump #1 2.73E+00 2.73E+00 0.0018 0.0456 Pu-241 3.64E+04 Sump #1 4.10E+01 4.10E+01 0.0011 0.0282 Am-241 1.09E+03 Sump #1 1.04E+01 1.04E+01 0.0096 0.2388 Am-243 1.87E+02 Sump #1 4.36E-01 4.36E-01 0.0023 0.0584 Cm-243 2.88E+02 Sump #1 1.10E-01 1.10E-01 0.0004 0.0095 Cm-244 2.67E+03 Sump #1 1.10E-01 1.10E-01 0.0000 0.0010 0.6373
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L1-010-101-AJGS-007C-SS 1.18E+00 1.18E+00 0.0001 0.0017 C-14 2.45E+05 L1-010-101-AJGS-007C-SS
-9.97E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-101-AJGS-007C-SS 3.99E+00 3.99E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-101-AJGS-007C-SS
-1.30E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-101-AJGS-007C-SS 9.26E-03 9.26E-03 0.0007 0.0181 Ni-63 9.48E+06 L1-010-101-AJGS-007C-SS 6.62E-02 6.62E-02 0.0000 0.0000 Sr-90 6.59E+03 L1-010-101-AJGS-007C-SS
-5.48E-03 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-101-AJGS-007C-SS 1.66E-02 1.66E-02 0.0008 0.0206 Tc-99 3.56E+02 L1-010-101-AJGS-007C-SS
-8.62E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-101-AJGS-007C-SS 3.35E-02 3.35E-02 0.0006 0.0144 Eu-152 2.84E+01 L1-010-101-AJGS-007C-SS
-2.54E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-101-AJGS-007C-SS 4.40E-02 4.40E-02 0.0017 0.0417 Eu-155 1.12E+03 L1-010-101-AJGS-007C-SS 0.00E+00 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-101-AJGS-007C-SS
-2.32E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-101-AJGS-007C-SS 3.28E-04 3.28E-04 0.0000 0.0000 Pu-239 1.49E+03 L1-010-101-AJGS-007C-SS 1.05E-02 1.05E-02 0.0000 0.0002 Pu-240 1.50E+03 L1-010-101-AJGS-007C-SS 1.05E-02 1.05E-02 0.0000 0.0002 Pu-241 3.64E+04 L1-010-101-AJGS-007C-SS
-3.90E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-101-AJGS-007C-SS 2.30E-02 2.30E-02 0.0000 0.0005 Am-243 1.87E+02 L1-010-101-AJGS-007C-SS 1.44E-02 1.44E-02 0.0001 0.0019 Cm-243 2.88E+02 L1-010-101-AJGS-007C-SS
-1.24E-02 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-101-AJGS-007C-SS
-1.24E-02 0.00E+00 0.0000 0.0000 0.0251 H-3 1.75E+04 L1-010-101-AJGS-005-SS 5.28E-01 5.28E-01 0.0000 0.0008 C-14 2.45E+05 L1-010-101-AJGS-005-SS 8.41E-01 8.41E-01 0.0000 0.0001 Fe-55 1.02E+07 L1-010-101-AJGS-005-SS
-9.22E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-101-AJGS-005-SS 6.74E-01 6.74E-01 0.0000 0.0000 Co-60 1.28E+01 L1-010-101-AJGS-005-SS
-1.28E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-010-101-AJGS-005-SS
-8.82E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-101-AJGS-005-SS 8.92E-02 8.92E-02 0.0000 0.0003 Nb-94 2.02E+01 L1-010-101-AJGS-005-SS
-4.06E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-101-AJGS-005-SS
-3.03E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-101-AJGS-005-SS 1.93E-01 1.93E-01 0.0033 0.0830 Eu-152 2.84E+01 L1-010-101-AJGS-005-SS 4.96E-02 4.96E-02 0.0017 0.0436 Eu-154 2.64E+01 L1-010-101-AJGS-005-SS 3.51E-02 3.51E-02 0.0013 0.0333 Eu-155 1.12E+03 L1-010-101-AJGS-005-SS 3.20E-02 3.20E-02 0.0000 0.0007 Np-237 7.99E-01 L1-010-101-AJGS-005-SS
-5.68E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-101-AJGS-005-SS
-4.07E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-101-AJGS-005-SS 1.18E-02 1.18E-02 0.0000 0.0002 Pu-240 1.50E+03 L1-010-101-AJGS-005-SS 1.18E-02 1.18E-02 0.0000 0.0002 Pu-241 3.64E+04 L1-010-101-AJGS-005-SS
-9.79E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-101-AJGS-005-SS 6.25E-03 6.25E-03 0.0000 0.0001 Am-243 1.87E+02 L1-010-101-AJGS-005-SS
-8.38E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-101-AJGS-005-SS 4.79E-03 4.79E-03 0.0000 0.0004 Cm-244 2.67E+03 L1-010-101-AJGS-005-SS 4.79E-03 4.79E-03 0.0000 0.0000 0.0026 H-3 1.75E+04 L1-010-101-AJGS-010-SS
-1.39E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-101-AJGS-010-SS
-2.15E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-101-AJGS-010-SS
-3.01E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-101-AJGS-010-SS 4.13E+00 4.13E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-101-AJGS-010-SS
-1.10E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-010-101-AJGS-010-SS 4.89E-01 4.89E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-010-101-AJGS-010-SS
-4.63E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-101-AJGS-010-SS
-3.89E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-101-AJGS-010-SS
-5.14E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-101-AJGS-010-SS 3.24E-01 3.24E-01 0.0056 0.1394 Eu-152 2.84E+01 L1-010-101-AJGS-010-SS 6.10E-02 6.10E-02 0.0021 0.0536 Eu-154 2.64E+01 L1-010-101-AJGS-010-SS 2.41E-02 2.41E-02 0.0009 0.0229 Eu-155 1.12E+03 L1-010-101-AJGS-010-SS 5.32E-02 5.32E-02 0.0000 0.0012 Np-237 7.99E-01 L1-010-101-AJGS-010-SS
-2.40E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-101-AJGS-010-SS
-2.43E-02 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-101-AJGS-010-SS
-1.49E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-101-AJGS-010-SS
-1.49E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-101-AJGS-010-SS
-1.85E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-101-AJGS-010-SS
-7.21E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-010-101-AJGS-010-SS
-1.91E-02 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-101-AJGS-010-SS
-1.59E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-101-AJGS-010-SS
-1.59E-03 0.00E+00 0.0000 0.0000 0.0012 H-3 1.75E+04 L1-010-101-AJGS-001A-SS 2.54E+00 2.54E+00 0.0001 0.0036 C-14 2.45E+05 L1-010-101-AJGS-001A-SS
-2.70E+00 0.00E+00 0.0000 0.0000
Fe-55 1.02E+07 L1-010-101-AJGS-001A-SS
-1.91E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-101-AJGS-001A-SS
-8.02E-02 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-101-AJGS-001A-SS 5.95E-02 5.95E-02 0.0046 0.1161 Ni-63 9.48E+06 L1-010-101-AJGS-001A-SS 4.61E-02 4.61E-02 0.0000 0.0000 Sr-90 6.59E+03 L1-010-101-AJGS-001A-SS 4.66E-02 4.66E-02 0.0000 0.0002 Nb-94 2.02E+01 L1-010-101-AJGS-001A-SS
-3.16E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-101-AJGS-001A-SS
-8.79E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-101-AJGS-001A-SS 4.22E-01 4.22E-01 0.0073 0.1815 Eu-152 2.84E+01 L1-010-101-AJGS-001A-SS
-8.53E-03 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-101-AJGS-001A-SS 2.31E-02 2.31E-02 0.0009 0.0219 Eu-155 1.12E+03 L1-010-101-AJGS-001A-SS
-1.25E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-101-AJGS-001A-SS
-1.10E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-101-AJGS-001A-SS
-1.37E-02 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-101-AJGS-001A-SS
-1.14E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-101-AJGS-001A-SS
-1.14E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-101-AJGS-001A-SS 9.90E-02 9.90E-02 0.0000 0.0001 Am-241 1.09E+03 L1-010-101-AJGS-001A-SS 2.30E-03 2.30E-03 0.0000 0.0001 Am-243 1.87E+02 L1-010-101-AJGS-001A-SS 9.03E-03 9.03E-03 0.0000 0.0012 Cm-243 2.88E+02 L1-010-101-AJGS-001A-SS
-1.03E-02 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-101-AJGS-001A-SS
-1.03E-02 0.00E+00 0.0000 0.0000 0.0050 H-3 1.75E+04 L1-010-101-AJGS-008-SS 3.83E-01 3.83E-01 0.0000 0.0005 C-14 2.45E+05 L1-010-101-AJGS-008-SS
-2.55E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-101-AJGS-008-SS 3.29E-02 3.29E-02 0.0000 0.0000 Ni-59 2.59E+07 L1-010-101-AJGS-008-SS
-2.37E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-101-AJGS-008-SS 7.11E-03 7.11E-03 0.0006 0.0139 Ni-63 9.48E+06 L1-010-101-AJGS-008-SS
-4.78E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-101-AJGS-008-SS
-7.45E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-101-AJGS-008-SS
-1.13E-02 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-101-AJGS-008-SS
-4.18E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-101-AJGS-008-SS 8.73E-02 8.73E-02 0.0015 0.0376 Eu-152 2.84E+01 L1-010-101-AJGS-008-SS 3.33E-02 3.33E-02 0.0012 0.0293 Eu-154 2.64E+01 L1-010-101-AJGS-008-SS 1.39E-02 1.39E-02 0.0005 0.0132 Eu-155 1.12E+03 L1-010-101-AJGS-008-SS
-1.07E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-101-AJGS-008-SS
-8.06E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-101-AJGS-008-SS 2.46E-03 2.46E-03 0.0000 0.0000 Pu-239 1.49E+03 L1-010-101-AJGS-008-SS 3.07E-04 3.07E-04 0.0000 0.0000 Pu-240 1.50E+03 L1-010-101-AJGS-008-SS 3.07E-04 3.07E-04 0.0000 0.0000 Pu-241 3.64E+04 L1-010-101-AJGS-008-SS
-1.42E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-101-AJGS-008-SS 8.72E-03 8.72E-03 0.0000 0.0002 Am-243 1.87E+02 L1-010-101-AJGS-008-SS
-1.86E-02 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-101-AJGS-008-SS
-6.51E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-101-AJGS-008-SS
-6.51E-03 0.00E+00 0.0000 0.0000 0.0008
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L1-010-104-AJGS-003-SS
-2.39E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-104-AJGS-003-SS 5.53E-01 5.53E-01 0.0000 0.0001 Fe-55 1.02E+07 L1-010-104-AJGS-003-SS 3.97E+00 3.97E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-104-AJGS-003-SS
-5.76E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-104-AJGS-003-SS 3.28E-02 3.28E-02 0.0026 0.0640 Ni-63 9.48E+06 L1-010-104-AJGS-003-SS 3.21E-01 3.21E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-010-104-AJGS-003-SS
-1.67E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-104-AJGS-003-SS
-4.82E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-104-AJGS-003-SS
-8.33E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-104-AJGS-003-SS 2.42E-01 2.42E-01 0.0042 0.1041 Eu-152 2.84E+01 L1-010-104-AJGS-003-SS
-4.54E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-104-AJGS-003-SS 5.72E-03 5.72E-03 0.0002 0.0054 Eu-155 1.12E+03 L1-010-104-AJGS-003-SS 7.67E-03 7.67E-03 0.0000 0.0002 Np-237 7.99E-01 L1-010-104-AJGS-003-SS
-1.33E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-104-AJGS-003-SS
-9.20E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-104-AJGS-003-SS 6.68E-03 6.68E-03 0.0000 0.0001 Pu-240 1.50E+03 L1-010-104-AJGS-003-SS 6.68E-03 6.68E-03 0.0000 0.0001 Pu-241 3.64E+04 L1-010-104-AJGS-003-SS 1.93E+00 1.93E+00 0.0001 0.0013 Am-241 1.09E+03 L1-010-104-AJGS-003-SS 8.45E-03 8.45E-03 0.0000 0.0002 Am-243 1.87E+02 L1-010-104-AJGS-003-SS 1.39E-02 1.39E-02 0.0001 0.0019 Cm-243 2.88E+02 L1-010-104-AJGS-003-SS 1.36E-02 1.36E-02 0.0000 0.0012 Cm-244 2.67E+03 L1-010-104-AJGS-003-SS 1.36E-02 1.36E-02 0.0000 0.0001 0.0051 H-3 1.75E+04 L1-010-104-AJGS-013-SS
-4.18E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-104-AJGS-013-SS
-1.57E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-104-AJGS-013-SS 7.53E-01 7.53E-01 0.0000 0.0000 Ni-59 2.59E+07 L1-010-104-AJGS-013-SS 1.16E-01 1.16E-01 0.0000 0.0000 Co-60 1.28E+01 L1-010-104-AJGS-013-SS 1.46E-01 1.46E-01 0.0114 0.2849 Ni-63 9.48E+06 L1-010-104-AJGS-013-SS
-3.16E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-104-AJGS-013-SS
-4.94E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-104-AJGS-013-SS 2.31E-02 2.31E-02 0.0011 0.0286 Tc-99 3.56E+02 L1-010-104-AJGS-013-SS 6.57E-02 6.57E-02 0.0002 0.0046 Cs-137 5.81E+01 L1-010-104-AJGS-013-SS 1.32E-01 1.32E-01 0.0023 0.0568 Eu-152 2.84E+01 L1-010-104-AJGS-013-SS
-3.21E-03 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-104-AJGS-013-SS
-1.24E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-104-AJGS-013-SS
-1.97E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-104-AJGS-013-SS 3.23E-04 3.23E-04 0.0004 0.0101 Pu-238 1.66E+03 L1-010-104-AJGS-013-SS 4.48E-03 4.48E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-010-104-AJGS-013-SS
-1.94E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-104-AJGS-013-SS
-1.94E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-104-AJGS-013-SS 3.29E-01 3.29E-01 0.0000 0.0002 Am-241 1.09E+03 L1-010-104-AJGS-013-SS 5.86E-03 5.86E-03 0.0000 0.0001 Am-243 1.87E+02 L1-010-104-AJGS-013-SS
-4.72E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-104-AJGS-013-SS 2.91E-04 2.91E-04 0.0000 0.0000 Cm-244 2.67E+03 L1-010-104-AJGS-013-SS 2.91E-04 2.91E-04 0.0000 0.0000 0.0438 H-3 1.75E+04 L1-010-104-AJGS-014-SS
-1.10E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-104-AJGS-014-SS
-2.19E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-104-AJGS-014-SS 1.97E+00 1.97E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-104-AJGS-014-SS
-2.91E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-104-AJGS-014-SS 2.59E-02 2.59E-02 0.0020 0.0505 Ni-63 9.48E+06 L1-010-104-AJGS-014-SS 3.38E-01 3.38E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-010-104-AJGS-014-SS
-3.70E-03 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-104-AJGS-014-SS 9.65E-04 9.65E-04 0.0000 0.0012 Tc-99 3.56E+02 L1-010-104-AJGS-014-SS
-7.04E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-104-AJGS-014-SS 4.06E-01 4.06E-01 0.0070 0.1746 Eu-152 2.84E+01 L1-010-104-AJGS-014-SS 1.20E-02 1.20E-02 0.0004 0.0105 Eu-154 2.64E+01 L1-010-104-AJGS-014-SS 4.44E-02 4.44E-02 0.0017 0.0421 Eu-155 1.12E+03 L1-010-104-AJGS-014-SS
-3.98E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-104-AJGS-014-SS
-2.96E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-104-AJGS-014-SS
-3.24E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-104-AJGS-014-SS
-1.53E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-104-AJGS-014-SS
-1.53E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-104-AJGS-014-SS
-7.64E-02 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-104-AJGS-014-SS 1.57E-02 1.57E-02 0.0000 0.0004 Am-243 1.87E+02 L1-010-104-AJGS-014-SS 6.00E-03 6.00E-03 0.0000 0.0008
Cm-243 2.88E+02 L1-010-104-AJGS-014-SS
-1.66E-02 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-104-AJGS-014-SS
-1.66E-02 0.00E+00 0.0000 0.0000 0.0024 H-3 1.75E+04 L1-010-104-AJGS-021-SS 1.04E+00 1.04E+00 0.0001 0.0015 C-14 2.45E+05 L1-010-104-AJGS-021-SS
-2.05E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-104-AJGS-021-SS 3.54E+00 3.54E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-104-AJGS-021-SS 7.55E-01 7.55E-01 0.0000 0.0000 Co-60 1.28E+01 L1-010-104-AJGS-021-SS 5.68E-02 5.68E-02 0.0044 0.1109 Ni-63 9.48E+06 L1-010-104-AJGS-021-SS
-4.66E-02 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-104-AJGS-021-SS
-4.05E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-104-AJGS-021-SS 2.21E-02 2.21E-02 0.0011 0.0274 Tc-99 3.56E+02 L1-010-104-AJGS-021-SS 2.02E-01 2.02E-01 0.0006 0.0142 Cs-137 5.81E+01 L1-010-104-AJGS-021-SS 5.07E-01 5.07E-01 0.0087 0.2181 Eu-152 2.84E+01 L1-010-104-AJGS-021-SS 1.22E-02 1.22E-02 0.0004 0.0107 Eu-154 2.64E+01 L1-010-104-AJGS-021-SS 1.49E-02 1.49E-02 0.0006 0.0141 Eu-155 1.12E+03 L1-010-104-AJGS-021-SS 4.87E-03 4.87E-03 0.0000 0.0001 Np-237 7.99E-01 L1-010-104-AJGS-021-SS
-1.43E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-104-AJGS-021-SS 1.40E-02 1.40E-02 0.0000 0.0002 Pu-239 1.49E+03 L1-010-104-AJGS-021-SS 7.15E-03 7.15E-03 0.0000 0.0001 Pu-240 1.50E+03 L1-010-104-AJGS-021-SS 7.15E-03 7.15E-03 0.0000 0.0001 Pu-241 3.64E+04 L1-010-104-AJGS-021-SS
-5.58E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-104-AJGS-021-SS
-3.26E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-010-104-AJGS-021-SS 1.19E-03 1.19E-03 0.0000 0.0002 Cm-243 2.88E+02 L1-010-104-AJGS-021-SS
-1.68E-02 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-104-AJGS-021-SS
-1.68E-02 0.00E+00 0.0000 0.0000 0.0438 H-3 1.75E+04 L1-010-104-AJGS-022-SS
-2.20E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-104-AJGS-022-SS
-1.36E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-104-AJGS-022-SS 2.02E+00 2.02E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-104-AJGS-022-SS
-1.77E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-104-AJGS-022-SS 1.26E-01 1.26E-01 0.0098 0.2459 Ni-63 9.48E+06 L1-010-104-AJGS-022-SS 7.19E-01 7.19E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-010-104-AJGS-022-SS 4.30E-03 4.30E-03 0.0000 0.0000 Nb-94 2.02E+01 L1-010-104-AJGS-022-SS 1.18E-02 1.18E-02 0.0006 0.0146 Tc-99 3.56E+02 L1-010-104-AJGS-022-SS
-5.52E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-104-AJGS-022-SS 5.73E-01 5.73E-01 0.0099 0.2465 Eu-152 2.84E+01 L1-010-104-AJGS-022-SS
-3.03E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-104-AJGS-022-SS
-1.73E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-104-AJGS-022-SS
-2.87E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-104-AJGS-022-SS 2.17E-03 2.17E-03 0.0027 0.0679 Pu-238 1.66E+03 L1-010-104-AJGS-022-SS 2.12E-03 2.12E-03 0.0000 0.0000 Pu-239 1.49E+03 L1-010-104-AJGS-022-SS 3.34E-02 3.34E-02 0.0000 0.0006 Pu-240 1.50E+03 L1-010-104-AJGS-022-SS 3.34E-02 3.34E-02 0.0000 0.0006 Pu-241 3.64E+04 L1-010-104-AJGS-022-SS
-5.77E-02 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-104-AJGS-022-SS 2.32E-03 2.32E-03 0.0000 0.0001 Am-243 1.87E+02 L1-010-104-AJGS-022-SS
-1.82E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-104-AJGS-022-SS
-1.97E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-104-AJGS-022-SS
-1.97E-03 0.00E+00 0.0000 0.0000 0.0837
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L1-010-105-AJGS-005-SB
-1.19E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-105-AJGS-005-SB 9.20E-01 9.20E-01 0.0000 0.0001 Fe-55 1.02E+07 L1-010-105-AJGS-005-SB
-2.50E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-105-AJGS-005-SB 3.07E+00 3.07E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-105-AJGS-005-SB 1.86E-02 1.86E-02 0.0015 0.0363 Ni-63 9.48E+06 L1-010-105-AJGS-005-SB
-3.39E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-105-AJGS-005-SB 9.81E-02 9.81E-02 0.0000 0.0004 Nb-94 2.02E+01 L1-010-105-AJGS-005-SB
-4.69E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-105-AJGS-005-SB 1.62E-01 1.62E-01 0.0005 0.0114 Cs-137 5.81E+01 L1-010-105-AJGS-005-SB 1.79E-01 1.79E-01 0.0031 0.0770 Eu-152 2.84E+01 L1-010-105-AJGS-005-SB
-2.19E-03 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-105-AJGS-005-SB 1.85E-02 1.85E-02 0.0007 0.0175 Eu-155 1.12E+03 L1-010-105-AJGS-005-SB
-3.03E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-105-AJGS-005-SB
-3.15E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-105-AJGS-005-SB 1.58E-02 1.58E-02 0.0000 0.0002 Pu-239 1.49E+03 L1-010-105-AJGS-005-SB
-1.09E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-105-AJGS-005-SB
-1.09E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-105-AJGS-005-SB
-1.39E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-105-AJGS-005-SB 2.32E-02 2.32E-02 0.0000 0.0005 Am-243 1.87E+02 L1-010-105-AJGS-005-SB 6.70E-03 6.70E-03 0.0000 0.0009 Cm-243 2.88E+02 L1-010-105-AJGS-005-SB
-1.69E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-105-AJGS-005-SB
-1.69E-03 0.00E+00 0.0000 0.0000 0.0131 H-3 1.75E+04 L1-010-105-AJGS-007-SB
-5.52E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-105-AJGS-007-SB
-1.53E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-105-AJGS-007-SB
-4.52E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-105-AJGS-007-SB
-1.22E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-105-AJGS-007-SB 4.86E-03 4.86E-03 0.0004 0.0095 Ni-63 9.48E+06 L1-010-105-AJGS-007-SB
-7.63E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-105-AJGS-007-SB 5.10E-02 5.10E-02 0.0000 0.0002 Nb-94 2.02E+01 L1-010-105-AJGS-007-SB
-1.37E-02 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-105-AJGS-007-SB
-7.37E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-105-AJGS-007-SB 1.36E-01 1.36E-01 0.0023 0.0585 Eu-152 2.84E+01 L1-010-105-AJGS-007-SB
-9.05E-03 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-105-AJGS-007-SB
-4.62E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-105-AJGS-007-SB 4.76E-02 4.76E-02 0.0000 0.0011 Np-237 7.99E-01 L1-010-105-AJGS-007-SB
-3.37E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-105-AJGS-007-SB 3.35E-03 3.35E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-010-105-AJGS-007-SB 3.34E-03 3.34E-03 0.0000 0.0001 Pu-240 1.50E+03 L1-010-105-AJGS-007-SB 3.34E-03 3.34E-03 0.0000 0.0001 Pu-241 3.64E+04 L1-010-105-AJGS-007-SB
-2.42E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-105-AJGS-007-SB 9.35E-03 9.35E-03 0.0000 0.0002 Am-243 1.87E+02 L1-010-105-AJGS-007-SB 1.87E-02 1.87E-02 0.0001 0.0025 Cm-243 2.88E+02 L1-010-105-AJGS-007-SB 0.00E+00 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-105-AJGS-007-SB 0.00E+00 0.00E+00 0.0000 0.0000 0.0039
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L1-010-106-AJGS-004-SS 3.31E+00 3.31E+00 0.0002 0.0047 C-14 2.45E+05 L1-010-106-AJGS-004-SS
-7.28E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-106-AJGS-004-SS 5.88E+00 5.88E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-106-AJGS-004-SS 1.55E+00 1.55E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-106-AJGS-004-SS 2.19E-02 2.19E-02 0.0017 0.0427 Ni-63 9.48E+06 L1-010-106-AJGS-004-SS 7.01E-01 7.01E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-010-106-AJGS-004-SS
-3.48E-03 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-106-AJGS-004-SS
-1.84E-02 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-106-AJGS-004-SS
-1.09E+00 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-106-AJGS-004-SS 3.85E-02 3.85E-02 0.0007 0.0166 Eu-152 2.84E+01 L1-010-106-AJGS-004-SS 0.00E+00 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-106-AJGS-004-SS
-5.13E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-106-AJGS-004-SS
-3.91E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-106-AJGS-004-SS 2.54E-04 2.54E-04 0.0003 0.0079 Pu-238 1.66E+03 L1-010-106-AJGS-004-SS 2.23E-03 2.23E-03 0.0000 0.0000 Pu-239 1.49E+03 L1-010-106-AJGS-004-SS 3.60E-02 3.60E-02 0.0000 0.0006 Pu-240 1.50E+03 L1-010-106-AJGS-004-SS 3.60E-02 3.60E-02 0.0000 0.0006 Pu-241 3.64E+04 L1-010-106-AJGS-004-SS 4.84E-01 4.84E-01 0.0000 0.0003 Am-241 1.09E+03 L1-010-106-AJGS-004-SS 1.35E-02 1.35E-02 0.0000 0.0003 Am-243 1.87E+02 L1-010-106-AJGS-004-SS
-1.33E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-106-AJGS-004-SS 0.00E+00 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-106-AJGS-004-SS 0.00E+00 0.00E+00 0.0000 0.0000 0.0146 H-3 1.75E+04 L1-010-106-AJGS-006-SS 1.11E-01 1.11E-01 0.0000 0.0002 C-14 2.45E+05 L1-010-106-AJGS-006-SS
-4.43E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-106-AJGS-006-SS 1.15E+00 1.15E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-106-AJGS-006-SS 3.56E-01 3.56E-01 0.0000 0.0000 Co-60 1.28E+01 L1-010-106-AJGS-006-SS 9.67E-03 9.67E-03 0.0008 0.0189 Ni-63 9.48E+06 L1-010-106-AJGS-006-SS
-8.33E-02 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-106-AJGS-006-SS 2.89E-02 2.89E-02 0.0000 0.0001 Nb-94 2.02E+01 L1-010-106-AJGS-006-SS 1.04E-02 1.04E-02 0.0005 0.0129 Tc-99 3.56E+02 L1-010-106-AJGS-006-SS
-1.42E+00 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-106-AJGS-006-SS 8.86E-02 8.86E-02 0.0015 0.0381 Eu-152 2.84E+01 L1-010-106-AJGS-006-SS
-3.40E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-106-AJGS-006-SS 2.06E-02 2.06E-02 0.0008 0.0195 Eu-155 1.12E+03 L1-010-106-AJGS-006-SS 3.58E-04 3.58E-04 0.0000 0.0000 Np-237 7.99E-01 L1-010-106-AJGS-006-SS
-1.16E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-106-AJGS-006-SS 7.62E-03 7.62E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-010-106-AJGS-006-SS 1.56E-02 1.56E-02 0.0000 0.0003 Pu-240 1.50E+03 L1-010-106-AJGS-006-SS 1.56E-02 1.56E-02 0.0000 0.0003 Pu-241 3.64E+04 L1-010-106-AJGS-006-SS 1.85E-01 1.85E-01 0.0000 0.0001 Am-241 1.09E+03 L1-010-106-AJGS-006-SS 5.81E-03 5.81E-03 0.0000 0.0001 Am-243 1.87E+02 L1-010-106-AJGS-006-SS 4.34E-04 4.34E-04 0.0000 0.0001 Cm-243 2.88E+02 L1-010-106-AJGS-006-SS
-1.82E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-106-AJGS-006-SS
-1.82E-03 0.00E+00 0.0000 0.0000 0.0140 H-3 1.75E+04 L1-010-106-AJGS-015-SS 1.46E+00 1.46E+00 0.0001 0.0021 C-14 2.45E+05 L1-010-106-AJGS-015-SS
-2.73E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-106-AJGS-015-SS 5.98E+00 5.98E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-106-AJGS-015-SS 1.13E-01 1.13E-01 0.0000 0.0000 Co-60 1.28E+01 L1-010-106-AJGS-015-SS 7.60E-04 7.60E-04 0.0001 0.0015 Ni-63 9.48E+06 L1-010-106-AJGS-015-SS
-3.33E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-106-AJGS-015-SS 6.60E-02 6.60E-02 0.0000 0.0003 Nb-94 2.02E+01 L1-010-106-AJGS-015-SS
-2.89E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-106-AJGS-015-SS
-1.20E+00 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-106-AJGS-015-SS 1.58E-01 1.58E-01 0.0027 0.0680 Eu-152 2.84E+01 L1-010-106-AJGS-015-SS
-1.62E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-106-AJGS-015-SS
-6.21E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-106-AJGS-015-SS 2.05E-02 2.05E-02 0.0000 0.0005 Np-237 7.99E-01 L1-010-106-AJGS-015-SS 0.00E+00 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-106-AJGS-015-SS
-6.65E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-106-AJGS-015-SS 1.77E-02 1.77E-02 0.0000 0.0003 Pu-240 1.50E+03 L1-010-106-AJGS-015-SS 1.77E-02 1.77E-02 0.0000 0.0003 Pu-241 3.64E+04 L1-010-106-AJGS-015-SS 9.99E-01 9.99E-01 0.0000 0.0007 Am-241 1.09E+03 L1-010-106-AJGS-015-SS
-2.72E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-010-106-AJGS-015-SS 8.39E-03 8.39E-03 0.0000 0.0011 Cm-243 2.88E+02 L1-010-106-AJGS-015-SS
-8.09E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-106-AJGS-015-SS
-8.09E-03 0.00E+00 0.0000 0.0000 0.0050 H-3 1.75E+04 L1-010-106-AJGS-017A-SS
-1.23E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-106-AJGS-017A-SS
-1.86E-01 0.00E+00 0.0000 0.0000
Fe-55 1.02E+07 L1-010-106-AJGS-017A-SS 8.02E-01 8.02E-01 0.0000 0.0000 Ni-59 2.59E+07 L1-010-106-AJGS-017A-SS
-1.28E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-106-AJGS-017A-SS 1.74E-02 1.74E-02 0.0014 0.0340 Ni-63 9.48E+06 L1-010-106-AJGS-017A-SS
-7.13E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-106-AJGS-017A-SS
-5.05E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-106-AJGS-017A-SS 5.78E-03 5.78E-03 0.0003 0.0072 Tc-99 3.56E+02 L1-010-106-AJGS-017A-SS
-1.12E+00 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-106-AJGS-017A-SS 2.01E-03 2.01E-03 0.0000 0.0009 Eu-152 2.84E+01 L1-010-106-AJGS-017A-SS 1.39E-01 1.39E-01 0.0049 0.1222 Eu-154 2.64E+01 L1-010-106-AJGS-017A-SS 4.77E-02 4.77E-02 0.0018 0.0452 Eu-155 1.12E+03 L1-010-106-AJGS-017A-SS
-2.89E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-106-AJGS-017A-SS 3.34E-04 3.34E-04 0.0004 0.0104 Pu-238 1.66E+03 L1-010-106-AJGS-017A-SS 2.47E-03 2.47E-03 0.0000 0.0000 Pu-239 1.49E+03 L1-010-106-AJGS-017A-SS
-3.88E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-106-AJGS-017A-SS
-3.88E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-106-AJGS-017A-SS 1.78E+00 1.78E+00 0.0000 0.0012 Am-241 1.09E+03 L1-010-106-AJGS-017A-SS
-1.12E-02 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-010-106-AJGS-017A-SS
-3.00E-02 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-106-AJGS-017A-SS
-9.54E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-106-AJGS-017A-SS
-9.54E-03 0.00E+00 0.0000 0.0000 0.0189 H-3 1.75E+04 L1-010-106-AJGS-027A-SS
-4.08E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-106-AJGS-027A-SS
-2.85E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-106-AJGS-027A-SS 5.13E-02 5.13E-02 0.0000 0.0000 Ni-59 2.59E+07 L1-010-106-AJGS-027A-SS
-4.70E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-106-AJGS-027A-SS
-4.87E-03 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-010-106-AJGS-027A-SS
-6.69E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-106-AJGS-027A-SS 4.25E-02 4.25E-02 0.0000 0.0002 Nb-94 2.02E+01 L1-010-106-AJGS-027A-SS
-3.12E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-106-AJGS-027A-SS
-6.15E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-106-AJGS-027A-SS
-4.76E-03 0.00E+00 0.0000 0.0000 Eu-152 2.84E+01 L1-010-106-AJGS-027A-SS 3.18E-02 3.18E-02 0.0011 0.0280 Eu-154 2.64E+01 L1-010-106-AJGS-027A-SS 5.28E-02 5.28E-02 0.0020 0.0501 Eu-155 1.12E+03 L1-010-106-AJGS-027A-SS 4.61E-02 4.61E-02 0.0000 0.0010 Np-237 7.99E-01 L1-010-106-AJGS-027A-SS 2.92E-04 2.92E-04 0.0004 0.0091 Pu-238 1.66E+03 L1-010-106-AJGS-027A-SS
-8.33E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-106-AJGS-027A-SS
-5.55E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-106-AJGS-027A-SS
-5.55E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-106-AJGS-027A-SS 1.06E+00 1.06E+00 0.0000 0.0007 Am-241 1.09E+03 L1-010-106-AJGS-027A-SS 6.39E-04 6.39E-04 0.0000 0.0000 Am-243 1.87E+02 L1-010-106-AJGS-027A-SS
-2.02E-02 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-106-AJGS-027A-SS
-5.38E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-106-AJGS-027A-SS
-5.38E-03 0.00E+00 0.0000 0.0000 0.0109 H-3 1.75E+04 L1-010-106-AJGS-029-SS 8.24E-01 8.24E-01 0.0000 0.0012 C-14 2.45E+05 L1-010-106-AJGS-029-SS
-9.42E-02 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-106-AJGS-029-SS 4.69E-01 4.69E-01 0.0000 0.0000 Ni-59 2.59E+07 L1-010-106-AJGS-029-SS
-9.47E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-106-AJGS-029-SS 0.00E+00 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-010-106-AJGS-029-SS 4.39E-01 4.39E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-010-106-AJGS-029-SS
-4.91E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-106-AJGS-029-SS 2.50E-02 2.50E-02 0.0012 0.0310 Tc-99 3.56E+02 L1-010-106-AJGS-029-SS
-1.09E+00 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-106-AJGS-029-SS 1.84E-01 1.84E-01 0.0032 0.0791 Eu-152 2.84E+01 L1-010-106-AJGS-029-SS 4.47E-02 4.47E-02 0.0016 0.0393 Eu-154 2.64E+01 L1-010-106-AJGS-029-SS 1.86E-02 1.86E-02 0.0007 0.0176 Eu-155 1.12E+03 L1-010-106-AJGS-029-SS 3.45E-02 3.45E-02 0.0000 0.0008 Np-237 7.99E-01 L1-010-106-AJGS-029-SS 8.66E-04 8.66E-04 0.0011 0.0271 Pu-238 1.66E+03 L1-010-106-AJGS-029-SS
-1.02E-02 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-106-AJGS-029-SS 2.13E-02 2.13E-02 0.0000 0.0004 Pu-240 1.50E+03 L1-010-106-AJGS-029-SS 2.13E-02 2.13E-02 0.0000 0.0004 Pu-241 3.64E+04 L1-010-106-AJGS-029-SS
-4.19E-01 0.00E+00 0.0000 0.0000
Am-241 1.09E+03 L1-010-106-AJGS-029-SS 7.57E-03 7.57E-03 0.0000 0.0002 Am-243 1.87E+02 L1-010-106-AJGS-029-SS
-8.69E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-106-AJGS-029-SS
-1.13E-02 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-106-AJGS-029-SS
-1.13E-02 0.00E+00 0.0000 0.0000 0.0609 H-3 1.75E+04 L1-010-106-AJGS-032A-SS
-1.70E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-106-AJGS-032A-SS 2.22E-01 2.22E-01 0.0000 0.0000 Fe-55 1.02E+07 L1-010-106-AJGS-032A-SS 2.74E+00 2.74E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-106-AJGS-032A-SS
-9.53E-03 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-106-AJGS-032A-SS 5.37E-03 5.37E-03 0.0004 0.0105 Ni-63 9.48E+06 L1-010-106-AJGS-032A-SS
-1.01E+00 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-106-AJGS-032A-SS 7.64E-02 7.64E-02 0.0000 0.0003 Nb-94 2.02E+01 L1-010-106-AJGS-032A-SS
-9.53E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-106-AJGS-032A-SS
-5.88E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-106-AJGS-032A-SS
-5.79E-03 0.00E+00 0.0000 0.0000 Eu-152 2.84E+01 L1-010-106-AJGS-032A-SS
-3.48E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-106-AJGS-032A-SS 2.97E-02 2.97E-02 0.0011 0.0282 Eu-155 1.12E+03 L1-010-106-AJGS-032A-SS 5.63E-02 5.63E-02 0.0001 0.0013 Np-237 7.99E-01 L1-010-106-AJGS-032A-SS 1.86E-03 1.86E-03 0.0023 0.0582 Pu-238 1.66E+03 L1-010-106-AJGS-032A-SS
-7.27E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-106-AJGS-032A-SS 2.72E-03 2.72E-03 0.0000 0.0000 Pu-240 1.50E+03 L1-010-106-AJGS-032A-SS 2.72E-03 2.72E-03 0.0000 0.0000 Pu-241 3.64E+04 L1-010-106-AJGS-032A-SS 9.68E-01 9.68E-01 0.0000 0.0007 Am-241 1.09E+03 L1-010-106-AJGS-032A-SS 1.07E-02 1.07E-02 0.0000 0.0002 Am-243 1.87E+02 L1-010-106-AJGS-032A-SS 1.42E-02 1.42E-02 0.0001 0.0019 Cm-243 2.88E+02 L1-010-106-AJGS-032A-SS
-6.68E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-106-AJGS-032A-SS
-6.68E-03 0.00E+00 0.0000 0.0000 0.0624 H-3 1.75E+04 L1-010-106-AJGS-035A-SS
-1.91E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-106-AJGS-035A-SS
-6.25E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-106-AJGS-035A-SS 2.15E+00 2.15E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-106-AJGS-035A-SS 1.88E+00 1.88E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-106-AJGS-035A-SS
-1.33E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-010-106-AJGS-035A-SS 1.09E+00 1.09E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-106-AJGS-035A-SS
-6.36E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-106-AJGS-035A-SS
-1.38E-02 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-106-AJGS-035A-SS
-7.41E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-106-AJGS-035A-SS 1.03E-02 1.03E-02 0.0002 0.0044 Eu-152 2.84E+01 L1-010-106-AJGS-035A-SS
-7.73E-03 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-106-AJGS-035A-SS
-4.75E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-106-AJGS-035A-SS
-3.71E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-106-AJGS-035A-SS
-2.43E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-106-AJGS-035A-SS 8.70E-04 8.70E-04 0.0000 0.0000 Pu-239 1.49E+03 L1-010-106-AJGS-035A-SS
-6.95E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-106-AJGS-035A-SS
-6.95E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-106-AJGS-035A-SS 1.29E+00 1.29E+00 0.0000 0.0009 Am-241 1.09E+03 L1-010-106-AJGS-035A-SS 2.24E-03 2.24E-03 0.0000 0.0001 Am-243 1.87E+02 L1-010-106-AJGS-035A-SS 1.26E-02 1.26E-02 0.0001 0.0017 Cm-243 2.88E+02 L1-010-106-AJGS-035A-SS
-1.66E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-106-AJGS-035A-SS
-1.66E-03 0.00E+00 0.0000 0.0000 0.0026 H-3 1.75E+04 L1-010-106-AJGS-041-SS
-6.05E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-106-AJGS-041-SS
-3.58E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-106-AJGS-041-SS 3.04E+00 3.04E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-106-AJGS-041-SS
-2.40E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-106-AJGS-041-SS 1.07E-02 1.07E-02 0.0008 0.0209 Ni-63 9.48E+06 L1-010-106-AJGS-041-SS
-5.89E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-106-AJGS-041-SS 2.13E-02 2.13E-02 0.0000 0.0001 Nb-94 2.02E+01 L1-010-106-AJGS-041-SS 2.60E-02 2.60E-02 0.0013 0.0322 Tc-99 3.56E+02 L1-010-106-AJGS-041-SS
-9.37E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-106-AJGS-041-SS
-1.49E-02 0.00E+00 0.0000 0.0000 Eu-152 2.84E+01 L1-010-106-AJGS-041-SS
-4.93E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-106-AJGS-041-SS 1.53E-01 1.53E-01 0.0058 0.1451 Eu-155 1.12E+03 L1-010-106-AJGS-041-SS 5.18E-02 5.18E-02 0.0000 0.0012 Np-237 7.99E-01 L1-010-106-AJGS-041-SS
-3.47E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-106-AJGS-041-SS
-1.12E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-106-AJGS-041-SS
-2.81E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-106-AJGS-041-SS
-2.81E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-106-AJGS-041-SS
-4.69E-02 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-106-AJGS-041-SS 6.52E-03 6.52E-03 0.0000 0.0001 Am-243 1.87E+02 L1-010-106-AJGS-041-SS 2.13E-03 2.13E-03 0.0000 0.0003 Cm-243 2.88E+02 L1-010-106-AJGS-041-SS
-4.22E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-106-AJGS-041-SS
-4.22E-03 0.00E+00 0.0000 0.0000 0.0338
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L1-010-107-AJGS-001C-SS
-1.09E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-107-AJGS-001C-SS
-7.51E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-107-AJGS-001C-SS 3.39E+00 3.39E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-107-AJGS-001C-SS 3.65E-01 3.65E-01 0.0000 0.0000 Co-60 1.28E+01 L1-010-107-AJGS-001C-SS 1.35E-03 1.35E-03 0.0001 0.0026 Ni-63 9.48E+06 L1-010-107-AJGS-001C-SS 1.71E-01 1.71E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-010-107-AJGS-001C-SS
-5.86E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-107-AJGS-001C-SS 1.78E-02 1.78E-02 0.0009 0.0221 Tc-99 3.56E+02 L1-010-107-AJGS-001C-SS
-3.57E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-107-AJGS-001C-SS 2.00E-01 2.00E-01 0.0034 0.0860 Eu-152 2.84E+01 L1-010-107-AJGS-001C-SS
-2.75E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-107-AJGS-001C-SS
-2.51E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-107-AJGS-001C-SS 9.35E-03 9.35E-03 0.0000 0.0002 Np-237 7.99E-01 L1-010-107-AJGS-001C-SS 1.28E-03 1.28E-03 0.0016 0.0400 Pu-238 1.66E+03 L1-010-107-AJGS-001C-SS 1.20E-02 1.20E-02 0.0000 0.0002 Pu-239 1.49E+03 L1-010-107-AJGS-001C-SS 1.71E-02 1.71E-02 0.0000 0.0003 Pu-240 1.50E+03 L1-010-107-AJGS-001C-SS 1.71E-02 1.71E-02 0.0000 0.0003 Pu-241 3.64E+04 L1-010-107-AJGS-001C-SS
-1.23E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-107-AJGS-001C-SS 1.80E-02 1.80E-02 0.0000 0.0004 Am-243 1.87E+02 L1-010-107-AJGS-001C-SS 2.96E-02 2.96E-02 0.0002 0.0040 Cm-243 2.88E+02 L1-010-107-AJGS-001C-SS 0.00E+00 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-107-AJGS-001C-SS 0.00E+00 0.00E+00 0.0000 0.0000 0.0674 H-3 1.75E+04 L1-010-107-AJGS-006A-SS 2.19E-01 2.19E-01 0.0000 0.0003 C-14 2.45E+05 L1-010-107-AJGS-006A-SS
-1.70E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-107-AJGS-006A-SS 3.12E+00 3.12E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-107-AJGS-006A-SS
-2.52E-02 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-107-AJGS-006A-SS 1.56E-01 1.56E-01 0.0122 0.3044 Ni-63 9.48E+06 L1-010-107-AJGS-006A-SS
-9.79E-02 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-107-AJGS-006A-SS 4.15E-02 4.15E-02 0.0000 0.0002 Nb-94 2.02E+01 L1-010-107-AJGS-006A-SS 7.63E-03 7.63E-03 0.0004 0.0095 Tc-99 3.56E+02 L1-010-107-AJGS-006A-SS
-3.41E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-107-AJGS-006A-SS 4.60E-01 4.60E-01 0.0079 0.1979 Eu-152 2.84E+01 L1-010-107-AJGS-006A-SS 5.00E-01 5.00E-01 0.0176 0.4395 Eu-154 2.64E+01 L1-010-107-AJGS-006A-SS
-6.90E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-107-AJGS-006A-SS 6.68E-03 6.68E-03 0.0000 0.0001 Np-237 7.99E-01 L1-010-107-AJGS-006A-SS
-8.35E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-107-AJGS-006A-SS 3.49E-03 3.49E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-010-107-AJGS-006A-SS 8.56E-03 8.56E-03 0.0000 0.0001 Pu-240 1.50E+03 L1-010-107-AJGS-006A-SS 8.56E-03 8.56E-03 0.0000 0.0001 Pu-241 3.64E+04 L1-010-107-AJGS-006A-SS 2.83E-01 2.83E-01 0.0000 0.0002 Am-241 1.09E+03 L1-010-107-AJGS-006A-SS 5.19E-03 5.19E-03 0.0000 0.0001 Am-243 1.87E+02 L1-010-107-AJGS-006A-SS
-1.16E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-107-AJGS-006A-SS 6.45E-03 6.45E-03 0.0000 0.0006 Cm-244 2.67E+03 L1-010-107-AJGS-006A-SS 6.45E-03 6.45E-03 0.0000 0.0001 0.0112 H-3 1.75E+04 L1-010-107-AJGS-011-SS
-1.58E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-107-AJGS-011-SS
-9.22E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-107-AJGS-011-SS 4.81E+00 4.81E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-107-AJGS-011-SS 2.58E+00 2.58E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-107-AJGS-011-SS 3.27E-02 3.27E-02 0.0026 0.0638 Ni-63 9.48E+06 L1-010-107-AJGS-011-SS 4.68E-02 4.68E-02 0.0000 0.0000 Sr-90 6.59E+03 L1-010-107-AJGS-011-SS 3.81E-03 3.81E-03 0.0000 0.0000 Nb-94 2.02E+01 L1-010-107-AJGS-011-SS 7.91E-03 7.91E-03 0.0004 0.0098 Tc-99 3.56E+02 L1-010-107-AJGS-011-SS 1.74E-01 1.74E-01 0.0005 0.0122 Cs-137 5.81E+01 L1-010-107-AJGS-011-SS 2.57E-02 2.57E-02 0.0004 0.0111 Eu-152 2.84E+01 L1-010-107-AJGS-011-SS
-4.41E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-107-AJGS-011-SS 3.51E-02 3.51E-02 0.0013 0.0333 Eu-155 1.12E+03 L1-010-107-AJGS-011-SS
-4.34E-03 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-010-107-AJGS-011-SS 0.00E+00 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-107-AJGS-011-SS
-2.56E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-107-AJGS-011-SS
-1.51E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-107-AJGS-011-SS
-1.51E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-107-AJGS-011-SS
-1.08E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-107-AJGS-011-SS
-1.28E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-010-107-AJGS-011-SS
-3.91E-03 0.00E+00 0.0000 0.0000
Cm-243 2.88E+02 L1-010-107-AJGS-011-SS
-7.62E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-107-AJGS-011-SS
-7.62E-03 0.00E+00 0.0000 0.0000 0.0220 H-3 1.75E+04 L1-010-107-AJGS-013-SS
-4.07E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-107-AJGS-013-SS 1.35E-01 1.35E-01 0.0000 0.0000 Fe-55 1.02E+07 L1-010-107-AJGS-013-SS 2.12E+00 2.12E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-107-AJGS-013-SS
-1.92E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-107-AJGS-013-SS
-2.45E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-010-107-AJGS-013-SS
-3.79E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-107-AJGS-013-SS
-9.00E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-107-AJGS-013-SS 6.90E-03 6.90E-03 0.0003 0.0085 Tc-99 3.56E+02 L1-010-107-AJGS-013-SS
-3.41E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-107-AJGS-013-SS 1.52E-01 1.52E-01 0.0026 0.0654 Eu-152 2.84E+01 L1-010-107-AJGS-013-SS 3.86E-02 3.86E-02 0.0014 0.0339 Eu-154 2.64E+01 L1-010-107-AJGS-013-SS
-2.61E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-107-AJGS-013-SS 5.29E-02 5.29E-02 0.0000 0.0012 Np-237 7.99E-01 L1-010-107-AJGS-013-SS 0.00E+00 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-107-AJGS-013-SS
-1.23E-02 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L1-010-107-AJGS-013-SS
-3.98E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-107-AJGS-013-SS
-3.98E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-107-AJGS-013-SS
-1.64E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-107-AJGS-013-SS
-1.21E-02 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-010-107-AJGS-013-SS
-1.94E-02 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-107-AJGS-013-SS 1.26E-02 1.26E-02 0.0000 0.0011 Cm-244 2.67E+03 L1-010-107-AJGS-013-SS 1.26E-02 1.26E-02 0.0000 0.0001 0.0110 H-3 1.75E+04 L1-010-107-AJGS-014-SS
-1.97E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-107-AJGS-014-SS
-3.16E-02 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-010-107-AJGS-014-SS 2.74E+00 2.74E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-107-AJGS-014-SS
-1.72E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-107-AJGS-014-SS 3.12E-03 3.12E-03 0.0002 0.0061 Ni-63 9.48E+06 L1-010-107-AJGS-014-SS
-7.22E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-107-AJGS-014-SS
-2.10E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-107-AJGS-014-SS
-8.78E-05 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-107-AJGS-014-SS
-1.99E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-107-AJGS-014-SS 1.11E-01 1.11E-01 0.0019 0.0477 Eu-152 2.84E+01 L1-010-107-AJGS-014-SS
-3.58E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-010-107-AJGS-014-SS
-3.18E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-107-AJGS-014-SS 1.73E-02 1.73E-02 0.0000 0.0004 Np-237 7.99E-01 L1-010-107-AJGS-014-SS
-1.07E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-107-AJGS-014-SS 4.67E-03 4.67E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-010-107-AJGS-014-SS 1.72E-03 1.72E-03 0.0000 0.0000 Pu-240 1.50E+03 L1-010-107-AJGS-014-SS 1.72E-03 1.72E-03 0.0000 0.0000 Pu-241 3.64E+04 L1-010-107-AJGS-014-SS 1.14E-01 1.14E-01 0.0000 0.0001 Am-241 1.09E+03 L1-010-107-AJGS-014-SS
-8.77E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-010-107-AJGS-014-SS
-1.70E-02 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L1-010-107-AJGS-014-SS 0.00E+00 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-107-AJGS-014-SS 0.00E+00 0.00E+00 0.0000 0.0000 0.0006 H-3 1.75E+04 L1-010-107-AJGS-017-SS
-3.10E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-010-107-AJGS-017-SS 1.08E+00 1.08E+00 0.0000 0.0001 Fe-55 1.02E+07 L1-010-107-AJGS-017-SS 3.63E+00 3.63E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-107-AJGS-017-SS
-4.18E-02 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-107-AJGS-017-SS
-7.19E-03 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-010-107-AJGS-017-SS 2.56E-01 2.56E-01 0.0000 0.0000 Sr-90 6.59E+03 L1-010-107-AJGS-017-SS 6.90E-02 6.90E-02 0.0000 0.0003 Nb-94 2.02E+01 L1-010-107-AJGS-017-SS
-5.00E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-107-AJGS-017-SS
-2.26E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-107-AJGS-017-SS 1.70E-01 1.70E-01 0.0029 0.0731 Eu-152 2.84E+01 L1-010-107-AJGS-017-SS 1.66E-02 1.66E-02 0.0006 0.0146 Eu-154 2.64E+01 L1-010-107-AJGS-017-SS 8.02E-03 8.02E-03 0.0003 0.0076 Eu-155 1.12E+03 L1-010-107-AJGS-017-SS 2.69E-02 2.69E-02 0.0000 0.0006 Np-237 7.99E-01 L1-010-107-AJGS-017-SS
-1.57E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-107-AJGS-017-SS 1.71E-02 1.71E-02 0.0000 0.0003 Pu-239 1.49E+03 L1-010-107-AJGS-017-SS 4.71E-03 4.71E-03 0.0000 0.0001 Pu-240 1.50E+03 L1-010-107-AJGS-017-SS 4.71E-03 4.71E-03 0.0000 0.0001 Pu-241 3.64E+04 L1-010-107-AJGS-017-SS
-5.24E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-010-107-AJGS-017-SS 2.35E-03 2.35E-03 0.0000 0.0001 Am-243 1.87E+02 L1-010-107-AJGS-017-SS 8.35E-03 8.35E-03 0.0000 0.0011
Cm-243 2.88E+02 L1-010-107-AJGS-017-SS
-3.21E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-107-AJGS-017-SS
-3.21E-03 0.00E+00 0.0000 0.0000 0.0023 H-3 1.75E+04 L1-010-107-AJGS-018-SS 1.45E+00 1.45E+00 0.0001 0.0021 C-14 2.45E+05 L1-010-107-AJGS-018-SS 4.51E-01 4.51E-01 0.0000 0.0000 Fe-55 1.02E+07 L1-010-107-AJGS-018-SS
-1.94E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-010-107-AJGS-018-SS 2.58E+00 2.58E+00 0.0000 0.0000 Co-60 1.28E+01 L1-010-107-AJGS-018-SS 2.09E-02 2.09E-02 0.0016 0.0408 Ni-63 9.48E+06 L1-010-107-AJGS-018-SS
-3.93E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-010-107-AJGS-018-SS
-9.07E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-010-107-AJGS-018-SS
-8.92E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-010-107-AJGS-018-SS
-1.47E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-010-107-AJGS-018-SS 1.26E-01 1.26E-01 0.0022 0.0542 Eu-152 2.84E+01 L1-010-107-AJGS-018-SS 6.11E-02 6.11E-02 0.0021 0.0537 Eu-154 2.64E+01 L1-010-107-AJGS-018-SS
-3.23E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-010-107-AJGS-018-SS 2.28E-02 2.28E-02 0.0000 0.0005 Np-237 7.99E-01 L1-010-107-AJGS-018-SS
-2.56E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-010-107-AJGS-018-SS 4.27E-03 4.27E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-010-107-AJGS-018-SS
-1.10E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L1-010-107-AJGS-018-SS
-1.10E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L1-010-107-AJGS-018-SS 4.99E-01 4.99E-01 0.0000 0.0003 Am-241 1.09E+03 L1-010-107-AJGS-018-SS
-4.81E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L1-010-107-AJGS-018-SS 1.22E-02 1.22E-02 0.0001 0.0016 Cm-243 2.88E+02 L1-010-107-AJGS-018-SS
-1.59E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-010-107-AJGS-018-SS
-1.59E-03 0.00E+00 0.0000 0.0000 0.0047
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L2-SUB-WRS-ASGS-10A-SB 2.56E+00 2.56E+00 0.0001 0.0037 C-14 2.45E+05 L2-SUB-WRS-ASGS-10A-SB
-3.08E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L2-SUB-WRS-ASGS-10A-SB
-3.58E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L2-SUB-WRS-ASGS-10A-SB 7.07E-03 7.07E-03 0.0000 0.0000 Co-60 1.28E+01 L2-SUB-WRS-ASGS-10A-SB 3.21E-02 3.21E-02 0.0025 0.0626 Ni-63 9.48E+06 L2-SUB-WRS-ASGS-10A-SB
-4.78E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L2-SUB-WRS-ASGS-10A-SB
-8.72E-03 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L2-SUB-WRS-ASGS-10A-SB 5.36E-02 5.36E-02 0.0027 0.0664 Tc-99 3.56E+02 L2-SUB-WRS-ASGS-10A-SB 4.25E-02 4.25E-02 0.0001 0.0030 Cs-137 5.81E+01 L2-SUB-WRS-ASGS-10A-SB 3.41E-02 3.41E-02 0.0006 0.0147 Eu-152 2.84E+01 L2-SUB-WRS-ASGS-10A-SB 3.90E-02 3.90E-02 0.0014 0.0343 Eu-154 2.64E+01 L2-SUB-WRS-ASGS-10A-SB
-3.00E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L2-SUB-WRS-ASGS-10A-SB 4.28E-02 4.28E-02 0.0000 0.0010 Np-237 7.99E-01 L2-SUB-WRS-ASGS-10A-SB
-5.46E-02 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L2-SUB-WRS-ASGS-10A-SB 9.43E-02 9.43E-02 0.0001 0.0014 Pu-239 1.49E+03 L2-SUB-WRS-ASGS-10A-SB
-7.88E-04 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L2-SUB-WRS-ASGS-10A-SB
-7.88E-04 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L2-SUB-WRS-ASGS-10A-SB
-8.38E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L2-SUB-WRS-ASGS-10A-SB 4.62E-02 4.62E-02 0.0000 0.0011 Am-243 1.87E+02 L2-SUB-WRS-ASGS-10A-SB 2.89E-02 2.89E-02 0.0002 0.0039 Cm-243 2.88E+02 L2-SUB-WRS-ASGS-10A-SB 0.00E+00 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L2-SUB-WRS-ASGS-10A-SB 0.00E+00 0.00E+00 0.0000 0.0000 0.0804 H-3 1.75E+04 L2-SUB-WRS-AJGS-15A-SB 5.69E-02 5.69E-02 0.0000 0.0001 C-14 2.45E+05 L2-SUB-WRS-AJGS-15A-SB
-1.75E+00 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L2-SUB-WRS-AJGS-15A-SB
-7.22E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L2-SUB-WRS-AJGS-15A-SB
-1.86E-02 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L2-SUB-WRS-AJGS-15A-SB
-8.37E-03 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L2-SUB-WRS-AJGS-15A-SB 5.70E-01 5.70E-01 0.0000 0.0000 Sr-90 6.59E+03 L2-SUB-WRS-AJGS-15A-SB
-6.96E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L2-SUB-WRS-AJGS-15A-SB
-4.00E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L2-SUB-WRS-AJGS-15A-SB
-3.04E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L2-SUB-WRS-AJGS-15A-SB 1.87E-01 1.87E-01 0.0032 0.0804 Eu-152 2.84E+01 L2-SUB-WRS-AJGS-15A-SB 1.15E-02 1.15E-02 0.0004 0.0101 Eu-154 2.64E+01 L2-SUB-WRS-AJGS-15A-SB
-1.29E-01 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L2-SUB-WRS-AJGS-15A-SB 4.86E-02 4.86E-02 0.0000 0.0011 Np-237 7.99E-01 L2-SUB-WRS-AJGS-15A-SB
-4.56E-02 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L2-SUB-WRS-AJGS-15A-SB
-3.11E-02 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L2-SUB-WRS-AJGS-15A-SB
-3.93E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L2-SUB-WRS-AJGS-15A-SB
-3.93E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L2-SUB-WRS-AJGS-15A-SB
-1.68E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L2-SUB-WRS-AJGS-15A-SB 1.79E-02 1.79E-02 0.0000 0.0004 Am-243 1.87E+02 L2-SUB-WRS-AJGS-15A-SB
-5.38E-04 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L2-SUB-WRS-AJGS-15A-SB
-6.03E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L2-SUB-WRS-AJGS-15A-SB
-6.03E-03 0.00E+00 0.0000 0.0000 0.0016
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 L2-SUB-102-AJGS-024-SB 2.40E+00 2.40E+00 0.0001 0.0034 C-14 2.45E+05 L2-SUB-102-AJGS-024-SB 6.17E-01 6.17E-01 0.0000 0.0001 Fe-55 1.02E+07 L2-SUB-102-AJGS-024-SB 2.06E+00 2.06E+00 0.0000 0.0000 Ni-59 2.59E+07 L2-SUB-102-AJGS-024-SB 5.77E-01 5.77E-01 0.0000 0.0000 Co-60 1.28E+01 L2-SUB-102-AJGS-024-SB 3.79E-02 3.79E-02 0.0030 0.0740 Ni-63 9.48E+06 L2-SUB-102-AJGS-024-SB 4.32E-01 4.32E-01 0.0000 0.0000 Sr-90 6.59E+03 L2-SUB-102-AJGS-024-SB
-2.23E-01 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L2-SUB-102-AJGS-024-SB 1.83E-02 1.83E-02 0.0009 0.0227 Tc-99 3.56E+02 L2-SUB-102-AJGS-024-SB 1.26E-01 1.26E-01 0.0004 0.0088 Cs-137 5.81E+01 L2-SUB-102-AJGS-024-SB 1.46E-03 1.46E-03 0.0000 0.0006 Eu-152 2.84E+01 L2-SUB-102-AJGS-024-SB 9.14E-03 9.14E-03 0.0003 0.0080 Eu-154 2.64E+01 L2-SUB-102-AJGS-024-SB 1.49E-02 1.49E-02 0.0006 0.0141 Eu-155 1.12E+03 L2-SUB-102-AJGS-024-SB 0.00E+00 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L2-SUB-102-AJGS-024-SB 1.31E-03 1.31E-03 0.0016 0.0410 Pu-238 1.66E+03 L2-SUB-102-AJGS-024-SB
-7.11E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 L2-SUB-102-AJGS-024-SB 3.12E-02 3.12E-02 0.0000 0.0005 Pu-240 1.50E+03 L2-SUB-102-AJGS-024-SB 3.12E-02 3.12E-02 0.0000 0.0005 Pu-241 3.64E+04 L2-SUB-102-AJGS-024-SB 9.35E-01 9.35E-01 0.0000 0.0006 Am-241 1.09E+03 L2-SUB-102-AJGS-024-SB 1.36E-02 1.36E-02 0.0000 0.0003 Am-243 1.87E+02 L2-SUB-102-AJGS-024-SB 1.57E-02 1.57E-02 0.0001 0.0021 Cm-243 2.88E+02 L2-SUB-102-AJGS-024-SB
-3.38E-05 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L2-SUB-102-AJGS-024-SB
-3.38E-05 0.00E+00 0.0000 0.0000 0.0801 H-3 1.75E+04 L2-SUB-102-AJGS-001-SB 2.31E+00 2.31E+00 0.0001 0.0033 C-14 2.45E+05 L2-SUB-102-AJGS-001-SB 5.26E-02 5.26E-02 0.0000 0.0000 Fe-55 1.02E+07 L2-SUB-102-AJGS-001-SB 1.36E+00 1.36E+00 0.0000 0.0000 Ni-59 2.59E+07 L2-SUB-102-AJGS-001-SB
-1.02E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L2-SUB-102-AJGS-001-SB
-4.19E-04 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L2-SUB-102-AJGS-001-SB
-3.71E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L2-SUB-102-AJGS-001-SB
-1.90E-01 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L2-SUB-102-AJGS-001-SB
-1.02E-02 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L2-SUB-102-AJGS-001-SB 6.69E-01 6.69E-01 0.0019 0.0469 Cs-137 5.81E+01 L2-SUB-102-AJGS-001-SB 0.00E+00 0.00E+00 0.0000 0.0000 Eu-152 2.84E+01 L2-SUB-102-AJGS-001-SB 1.63E-02 1.63E-02 0.0006 0.0143 Eu-154 2.64E+01 L2-SUB-102-AJGS-001-SB
-3.15E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L2-SUB-102-AJGS-001-SB 2.78E-02 2.78E-02 0.0000 0.0006 Np-237 7.99E-01 L2-SUB-102-AJGS-001-SB 1.70E-03 1.70E-03 0.0021 0.0532 Pu-238 1.66E+03 L2-SUB-102-AJGS-001-SB 6.62E-03 6.62E-03 0.0000 0.0001 Pu-239 1.49E+03 L2-SUB-102-AJGS-001-SB
-1.08E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 L2-SUB-102-AJGS-001-SB
-1.08E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 L2-SUB-102-AJGS-001-SB 1.06E+00 1.06E+00 0.0000 0.0007 Am-241 1.09E+03 L2-SUB-102-AJGS-001-SB 4.62E-03 4.62E-03 0.0000 0.0001 Am-243 1.87E+02 L2-SUB-102-AJGS-001-SB
-3.66E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 L2-SUB-102-AJGS-001-SB
-1.56E-02 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L2-SUB-102-AJGS-001-SB
-1.56E-02 0.00E+00 0.0000 0.0000 0.1050 H-3 1.75E+04 L2-SUB-102-AJGS-019-SB 2.76E+00 2.76E+00 0.0002 0.0040 C-14 2.45E+05 L2-SUB-102-AJGS-019-SB
-8.79E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L2-SUB-102-AJGS-019-SB
-1.89E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L2-SUB-102-AJGS-019-SB
-7.72E-02 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L2-SUB-102-AJGS-019-SB
-1.80E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L2-SUB-102-AJGS-019-SB
-4.74E-02 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L2-SUB-102-AJGS-019-SB
-2.28E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L2-SUB-102-AJGS-019-SB
-1.11E-02 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L2-SUB-102-AJGS-019-SB 1.96E-01 1.96E-01 0.0006 0.0138 Cs-137 5.81E+01 L2-SUB-102-AJGS-019-SB 4.45E-02 4.45E-02 0.0008 0.0191 Eu-152 2.84E+01 L2-SUB-102-AJGS-019-SB 1.06E-02 1.06E-02 0.0004 0.0093 Eu-154 2.64E+01 L2-SUB-102-AJGS-019-SB
-2.09E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L2-SUB-102-AJGS-019-SB 3.60E-02 3.60E-02 0.0000 0.0008 Np-237 7.99E-01 L2-SUB-102-AJGS-019-SB
-1.46E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L2-SUB-102-AJGS-019-SB 3.83E-02 3.83E-02 0.0000 0.0006 Pu-239 1.49E+03 L2-SUB-102-AJGS-019-SB 6.65E-03 6.65E-03 0.0000 0.0001 Pu-240 1.50E+03 L2-SUB-102-AJGS-019-SB 6.65E-03 6.65E-03 0.0000 0.0001 Pu-241 3.64E+04 L2-SUB-102-AJGS-019-SB
-5.96E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L2-SUB-102-AJGS-019-SB 5.58E-03 5.58E-03 0.0000 0.0001 Am-243 1.87E+02 L2-SUB-102-AJGS-019-SB 3.33E-03 3.33E-03 0.0000 0.0004 Cm-243 2.88E+02 L2-SUB-102-AJGS-019-SB 1.11E-02 1.11E-02 0.0000 0.0010 Cm-244 2.67E+03 L2-SUB-102-AJGS-019-SB 1.11E-02 1.11E-02 0.0000 0.0001 0.0209 H-3 1.75E+04 L2-SUB-102-AJGS-001-AV 3.40E+00 3.40E+00 0.0002 0.0049 C-14 2.45E+05 L2-SUB-102-AJGS-001-AV
-1.10E+00 0.00E+00 0.0000 0.0000
Fe-55 1.02E+07 L2-SUB-102-AJGS-001-AV 7.46E+00 7.46E+00 0.0000 0.0000 Ni-59 2.59E+07 L2-SUB-102-AJGS-001-AV
-1.54E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L2-SUB-102-AJGS-001-AV 8.50E-03 8.50E-03 0.0007 0.0166 Ni-63 9.48E+06 L2-SUB-102-AJGS-001-AV
-1.77E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 L2-SUB-102-AJGS-001-AV
-2.85E-03 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L2-SUB-102-AJGS-001-AV 5.19E-02 5.19E-02 0.0026 0.0643 Tc-99 3.56E+02 L2-SUB-102-AJGS-001-AV
-2.89E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L2-SUB-102-AJGS-001-AV 2.75E-03 2.75E-03 0.0000 0.0012 Eu-152 2.84E+01 L2-SUB-102-AJGS-001-AV 1.11E-02 1.11E-02 0.0004 0.0098 Eu-154 2.64E+01 L2-SUB-102-AJGS-001-AV
-3.00E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L2-SUB-102-AJGS-001-AV
-4.00E-03 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L2-SUB-102-AJGS-001-AV 6.68E-04 6.68E-04 0.0008 0.0209 Pu-238 1.66E+03 L2-SUB-102-AJGS-001-AV 7.61E-03 7.61E-03 0.0000 0.0001 Pu-239 1.49E+03 L2-SUB-102-AJGS-001-AV 2.05E-03 2.05E-03 0.0000 0.0000 Pu-240 1.50E+03 L2-SUB-102-AJGS-001-AV 2.05E-03 2.05E-03 0.0000 0.0000 Pu-241 3.64E+04 L2-SUB-102-AJGS-001-AV
-3.14E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L2-SUB-102-AJGS-001-AV
-9.80E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 L2-SUB-102-AJGS-001-AV 8.95E-03 8.95E-03 0.0000 0.0012 Cm-243 2.88E+02 L2-SUB-102-AJGS-001-AV
-1.14E-02 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L2-SUB-102-AJGS-001-AV
-1.14E-02 0.00E+00 0.0000 0.0000 0.0915
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 NRC #4 2.09E+00 2.09E+00 0.0001 0.0030 C-14 2.45E+05 NRC #4
-4.40E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 NRC #4 2.46E+00 2.46E+00 0.0000 0.0000 Ni-59 2.59E+07 NRC #4
-1.95E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 NRC #4 1.88E+01 1.88E+01 1.4676 36.6901 Ni-63 9.48E+06 NRC #4 5.04E+01 5.04E+01 0.0000 0.0001 Sr-90 6.59E+03 NRC #4 3.55E+00 3.55E+00 0.0005 0.0135 Nb-94 2.02E+01 NRC #4 5.41E-02 5.41E-02 0.0027 0.0670 Tc-99 3.56E+02 NRC #4 7.92E+00 7.92E+00 0.0222 0.5557 Cs-137 5.81E+01 NRC #4 1.71E+02 1.71E+02 2.9422 73.5547 Eu-152 2.84E+01 NRC #4
-9.59E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 NRC #4 1.65E-01 1.65E-01 0.0063 0.1565 Eu-155 1.12E+03 NRC #4 6.94E-02 6.94E-02 0.0001 0.0015 Np-237 7.99E-01 NRC #4
-2.26E-02 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 NRC #4 6.22E-01 6.22E-01 0.0004 0.0094 Pu-239 1.49E+03 NRC #4 6.15E-01 6.15E-01 0.0004 0.0103 Pu-240 1.50E+03 NRC #4 6.15E-01 6.15E-01 0.0004 0.0103 Pu-241 3.64E+04 NRC #4 6.57E+00 6.57E+00 0.0002 0.0045 Am-241 1.09E+03 NRC #4 2.03E+00 2.03E+00 0.0019 0.0466 Am-243 1.87E+02 NRC #4 1.37E-01 1.37E-01 0.0007 0.0183 Cm-243 2.88E+02 NRC #4 4.83E-02 4.83E-02 0.0002 0.0042 Cm-244 2.67E+03 NRC #4 4.83E-02 4.83E-02 0.0000 0.0005 0.7314 H-3 1.75E+04 L1-SUB-CDR-FSGS-008-SB 1.27E+00 1.27E+00 0.0001 0.0018 C-14 2.45E+05 L1-SUB-CDR-FSGS-008-SB 7.20E-01 7.20E-01 0.0000 0.0001 Fe-55 1.02E+07 L1-SUB-CDR-FSGS-008-SB
-2.22E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-CDR-FSGS-008-SB
-1.72E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-CDR-FSGS-008-SB 2.45E-02 2.45E-02 0.0019 0.0478 Ni-63 9.48E+06 L1-SUB-CDR-FSGS-008-SB 2.73E+00 2.73E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-CDR-FSGS-008-SB 2.48E-01 2.48E-01 0.0000 0.0009 Nb-94 2.02E+01 L1-SUB-CDR-FSGS-008-SB
-9.84E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-SUB-CDR-FSGS-008-SB
-2.08E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-CDR-FSGS-008-SB 8.04E-01 8.04E-01 0.0138 0.3458 Eu-152 2.84E+01 L1-SUB-CDR-FSGS-008-SB
-5.50E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-SUB-CDR-FSGS-008-SB
-1.04E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-CDR-FSGS-008-SB 3.93E-02 3.93E-02 0.0000 0.0009 Np-237 7.99E-01 L1-SUB-CDR-FSGS-008-SB 8.76E-03 8.76E-03 0.0110 0.2741 Pu-238 1.66E+03 L1-SUB-CDR-FSGS-008-SB 1.37E-02 1.37E-02 0.0000 0.0002 Pu-239 1.49E+03 L1-SUB-CDR-FSGS-008-SB 1.83E-04 1.83E-04 0.0000 0.0000 Pu-240 1.50E+03 L1-SUB-CDR-FSGS-008-SB 1.83E-04 1.83E-04 0.0000 0.0000 Pu-241 3.64E+04 L1-SUB-CDR-FSGS-008-SB
-1.46E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-CDR-FSGS-008-SB 2.41E-02 2.41E-02 0.0000 0.0006 Am-243 1.87E+02 L1-SUB-CDR-FSGS-008-SB 6.36E-02 6.36E-02 0.0003 0.0085 Cm-243 2.88E+02 L1-SUB-CDR-FSGS-008-SB
-1.95E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-CDR-FSGS-008-SB
-1.95E-03 0.00E+00 0.0000 0.0000 0.2861 H-3 1.75E+04 L1-SUB-CDR-FSGS-009-SB 3.39E+00 3.39E+00 0.0002 0.0049 C-14 2.45E+05 L1-SUB-CDR-FSGS-009-SB
-8.51E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-CDR-FSGS-009-SB 3.82E+00 3.82E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-CDR-FSGS-009-SB
-6.49E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-CDR-FSGS-009-SB 6.95E-01 6.95E-01 0.0543 1.3564 Ni-63 9.48E+06 L1-SUB-CDR-FSGS-009-SB 9.70E+00 9.70E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-CDR-FSGS-009-SB
-1.78E-01 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 L1-SUB-CDR-FSGS-009-SB 2.20E-04 2.20E-04 0.0000 0.0003 Tc-99 3.56E+02 L1-SUB-CDR-FSGS-009-SB
-3.10E-02 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-CDR-FSGS-009-SB 1.15E+01 1.15E+01 0.1979 4.9467 Eu-152 2.84E+01 L1-SUB-CDR-FSGS-009-SB
-8.43E-03 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 L1-SUB-CDR-FSGS-009-SB 2.73E-02 2.73E-02 0.0010 0.0259 Eu-155 1.12E+03 L1-SUB-CDR-FSGS-009-SB 6.39E-03 6.39E-03 0.0000 0.0001 Np-237 7.99E-01 L1-SUB-CDR-FSGS-009-SB
-1.37E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-SUB-CDR-FSGS-009-SB 1.07E-01 1.07E-01 0.0001 0.0016 Pu-239 1.49E+03 L1-SUB-CDR-FSGS-009-SB 1.18E-01 1.18E-01 0.0001 0.0020 Pu-240 1.50E+03 L1-SUB-CDR-FSGS-009-SB 1.18E-01 1.18E-01 0.0001 0.0020 Pu-241 3.64E+04 L1-SUB-CDR-FSGS-009-SB 2.53E+00 2.53E+00 0.0001 0.0017 Am-241 1.09E+03 L1-SUB-CDR-FSGS-009-SB 5.56E-01 5.56E-01 0.0005 0.0128 Am-243 1.87E+02 L1-SUB-CDR-FSGS-009-SB 4.35E-02 4.35E-02 0.0002 0.0058
Cm-243 2.88E+02 L1-SUB-CDR-FSGS-009-SB 9.31E-03 9.31E-03 0.0000 0.0008 Cm-244 2.67E+03 L1-SUB-CDR-FSGS-009-SB 9.31E-03 9.31E-03 0.0000 0.0001 0.0321 H-3 1.75E+04 L1-SUB-CDR-FSGS-011-SB
-2.87E-01 0.00E+00 0.0000 0.0000 C-14 2.45E+05 L1-SUB-CDR-FSGS-011-SB 3.52E-01 3.52E-01 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-CDR-FSGS-011-SB
-9.50E-01 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-CDR-FSGS-011-SB
-2.54E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-CDR-FSGS-011-SB 2.29E-01 2.29E-01 0.0179 0.4469 Ni-63 9.48E+06 L1-SUB-CDR-FSGS-011-SB 1.77E+00 1.77E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-CDR-FSGS-011-SB 7.87E-02 7.87E-02 0.0000 0.0003 Nb-94 2.02E+01 L1-SUB-CDR-FSGS-011-SB 1.59E-02 1.59E-02 0.0008 0.0197 Tc-99 3.56E+02 L1-SUB-CDR-FSGS-011-SB
-1.02E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-CDR-FSGS-011-SB 3.77E+00 3.77E+00 0.0649 1.6216 Eu-152 2.84E+01 L1-SUB-CDR-FSGS-011-SB 1.19E-02 1.19E-02 0.0004 0.0105 Eu-154 2.64E+01 L1-SUB-CDR-FSGS-011-SB 4.26E-02 4.26E-02 0.0016 0.0404 Eu-155 1.12E+03 L1-SUB-CDR-FSGS-011-SB 1.20E-02 1.20E-02 0.0000 0.0003 Np-237 7.99E-01 L1-SUB-CDR-FSGS-011-SB 1.81E-03 1.81E-03 0.0023 0.0566 Pu-238 1.66E+03 L1-SUB-CDR-FSGS-011-SB 7.90E-03 7.90E-03 0.0000 0.0001 Pu-239 1.49E+03 L1-SUB-CDR-FSGS-011-SB 1.66E-02 1.66E-02 0.0000 0.0003 Pu-240 1.50E+03 L1-SUB-CDR-FSGS-011-SB 1.66E-02 1.66E-02 0.0000 0.0003 Pu-241 3.64E+04 L1-SUB-CDR-FSGS-011-SB
-1.07E+00 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-CDR-FSGS-011-SB 7.71E-02 7.71E-02 0.0001 0.0018 Am-243 1.87E+02 L1-SUB-CDR-FSGS-011-SB 1.07E-02 1.07E-02 0.0001 0.0014 Cm-243 2.88E+02 L1-SUB-CDR-FSGS-011-SB 9.30E-04 9.30E-04 0.0000 0.0001 Cm-244 2.67E+03 L1-SUB-CDR-FSGS-011-SB 9.30E-04 9.30E-04 0.0000 0.0000 0.0806 H-3 1.75E+04 L1-SUB-CDR-FSGS-012-SB 1.54E+00 1.54E+00 0.0001 0.0022 C-14 2.45E+05 L1-SUB-CDR-FSGS-012-SB 1.18E-01 1.18E-01 0.0000 0.0000 Fe-55 1.02E+07 L1-SUB-CDR-FSGS-012-SB
-1.52E-01 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-CDR-FSGS-012-SB 7.17E-01 7.17E-01 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-CDR-FSGS-012-SB 0.00E+00 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 L1-SUB-CDR-FSGS-012-SB 1.58E+00 1.58E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-CDR-FSGS-012-SB 1.63E-01 1.63E-01 0.0000 0.0006 Nb-94 2.02E+01 L1-SUB-CDR-FSGS-012-SB
-7.59E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 L1-SUB-CDR-FSGS-012-SB 3.08E-01 3.08E-01 0.0009 0.0216 Cs-137 5.81E+01 L1-SUB-CDR-FSGS-012-SB 2.21E+00 2.21E+00 0.0380 0.9506 Eu-152 2.84E+01 L1-SUB-CDR-FSGS-012-SB 6.59E-02 6.59E-02 0.0023 0.0579 Eu-154 2.64E+01 L1-SUB-CDR-FSGS-012-SB
-8.13E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-CDR-FSGS-012-SB
-1.45E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-SUB-CDR-FSGS-012-SB 0.00E+00 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-SUB-CDR-FSGS-012-SB 1.75E-02 1.75E-02 0.0000 0.0003 Pu-239 1.49E+03 L1-SUB-CDR-FSGS-012-SB 1.76E-02 1.76E-02 0.0000 0.0003 Pu-240 1.50E+03 L1-SUB-CDR-FSGS-012-SB 1.76E-02 1.76E-02 0.0000 0.0003 Pu-241 3.64E+04 L1-SUB-CDR-FSGS-012-SB
-8.49E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-CDR-FSGS-012-SB 1.13E-01 1.13E-01 0.0001 0.0026 Am-243 1.87E+02 L1-SUB-CDR-FSGS-012-SB 2.95E-03 2.95E-03 0.0000 0.0004 Cm-243 2.88E+02 L1-SUB-CDR-FSGS-012-SB
-1.59E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-CDR-FSGS-012-SB
-1.59E-03 0.00E+00 0.0000 0.0000 0.0277 H-3 1.75E+04 L1-SUB-CDR-FSGS-014-SB 2.67E+00 2.67E+00 0.0002 0.0038 C-14 2.45E+05 L1-SUB-CDR-FSGS-014-SB 1.46E+00 1.46E+00 0.0000 0.0001 Fe-55 1.02E+07 L1-SUB-CDR-FSGS-014-SB 5.27E-01 5.27E-01 0.0000 0.0000 Ni-59 2.59E+07 L1-SUB-CDR-FSGS-014-SB
-1.92E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 L1-SUB-CDR-FSGS-014-SB 1.92E-01 1.92E-01 0.0150 0.3747 Ni-63 9.48E+06 L1-SUB-CDR-FSGS-014-SB 1.95E+00 1.95E+00 0.0000 0.0000 Sr-90 6.59E+03 L1-SUB-CDR-FSGS-014-SB 7.95E-02 7.95E-02 0.0000 0.0003 Nb-94 2.02E+01 L1-SUB-CDR-FSGS-014-SB 7.26E-03 7.26E-03 0.0004 0.0090 Tc-99 3.56E+02 L1-SUB-CDR-FSGS-014-SB
-7.83E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 L1-SUB-CDR-FSGS-014-SB 2.77E+00 2.77E+00 0.0477 1.1915 Eu-152 2.84E+01 L1-SUB-CDR-FSGS-014-SB 4.72E-02 4.72E-02 0.0017 0.0415 Eu-154 2.64E+01 L1-SUB-CDR-FSGS-014-SB
-7.85E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 L1-SUB-CDR-FSGS-014-SB
-2.68E-02 0.00E+00 0.0000 0.0000 Np-237 7.99E-01 L1-SUB-CDR-FSGS-014-SB
-2.03E-03 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 L1-SUB-CDR-FSGS-014-SB 1.60E-02 1.60E-02 0.0000 0.0002 Pu-239 1.49E+03 L1-SUB-CDR-FSGS-014-SB 1.11E-02 1.11E-02 0.0000 0.0002 Pu-240 1.50E+03 L1-SUB-CDR-FSGS-014-SB 1.11E-02 1.11E-02 0.0000 0.0002 Pu-241 3.64E+04 L1-SUB-CDR-FSGS-014-SB
-9.30E-01 0.00E+00 0.0000 0.0000 Am-241 1.09E+03 L1-SUB-CDR-FSGS-014-SB 7.96E-02 7.96E-02 0.0001 0.0018 Am-243 1.87E+02 L1-SUB-CDR-FSGS-014-SB 1.38E-02 1.38E-02 0.0001 0.0018 Cm-243 2.88E+02 L1-SUB-CDR-FSGS-014-SB
-1.92E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 L1-SUB-CDR-FSGS-014-SB
-1.92E-03 0.00E+00 0.0000 0.0000 0.0173
Radionuclide Unadjusted DCGL Sample Activity (pCi/g) Activity (pCi/g) (zero) Fraction Dose IC Dose H-3 1.75E+04 Clay Pipe Sample
-1.41E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 Clay Pipe Sample
-7.55E-01 0.00E+00 0.0000 0.0000 Fe-55 1.02E+07 Clay Pipe Sample
-4.00E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 Clay Pipe Sample
-2.94E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 Clay Pipe Sample
-4.06E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 Clay Pipe Sample 9.96E-01 9.96E-01 0.0000 0.0000 Sr-90 6.59E+03 Clay Pipe Sample 1.28E-01 1.28E-01 0.0000 0.0005 Nb-94 2.02E+01 Clay Pipe Sample 6.17E-02 6.17E-02 0.0031 0.0764 Tc-99 3.56E+02 Clay Pipe Sample
-1.79E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 Clay Pipe Sample
-3.78E-03 0.00E+00 0.0000 0.0000 Eu-152 2.84E+01 Clay Pipe Sample
-2.09E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 Clay Pipe Sample 1.29E-01 1.29E-01 0.0049 0.1223 Eu-155 1.12E+03 Clay Pipe Sample 6.16E-02 6.16E-02 0.0001 0.0014 Np-237 7.99E-01 Clay Pipe Sample
-5.25E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 Clay Pipe Sample 3.70E-03 3.70E-03 0.0000 0.0001 Pu-239 1.49E+03 Clay Pipe Sample
-1.36E-02 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 Clay Pipe Sample
-1.36E-02 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 Clay Pipe Sample 9.26E-01 9.26E-01 0.0000 0.0006 Am-241 1.09E+03 Clay Pipe Sample 3.27E-03 3.27E-03 0.0000 0.0001 Am-243 1.87E+02 Clay Pipe Sample 1.83E-02 1.83E-02 0.0001 0.0024 Cm-243 2.88E+02 Clay Pipe Sample
-2.07E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 Clay Pipe Sample
-2.07E-03 0.00E+00 0.0000 0.0000 0.0810
Radionuclide Unadjusted DCGL Sample Activity (pCi/g)
Activity (pCi/g) (zero)
Fraction Dose IC Dose H-3 1.75E+04 S3-012-109B-FJGS-062-SM
-1.80E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 S3-012-109B-FJGS-062-SM 1.01E+00 1.01E+00 0.0000 0.0001 Fe-55 1.02E+07 S3-012-109B-FJGS-062-SM
-3.87E-01 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 S3-012-109B-FJGS-062-SM
-1.09E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 S3-012-109B-FJGS-062-SM 5.70E-03 5.70E-03 0.0004 0.0111 Ni-63 9.48E+06 S3-012-109B-FJGS-062-SM
-1.24E+00 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 S3-012-109B-FJGS-062-SM
-5.20E-02 0.00E+00 0.0000 0.0000 Nb-94 2.02E+01 S3-012-109B-FJGS-062-SM
-7.10E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 S3-012-109B-FJGS-062-SM
-9.68E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 S3-012-109B-FJGS-062-SM 7.66E-03 7.66E-03 0.0001 0.0033 Eu-152 2.84E+01 S3-012-109B-FJGS-062-SM
-6.17E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 S3-012-109B-FJGS-062-SM
-5.89E-03 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 S3-012-109B-FJGS-062-SM 5.07E-02 5.07E-02 0.0000 0.0011 Np-237 7.99E-01 S3-012-109B-FJGS-062-SM 1.02E-03 1.02E-03 0.0013 0.0319 Pu-238 1.66E+03 S3-012-109B-FJGS-062-SM
-4.33E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 S3-012-109B-FJGS-062-SM 2.15E-03 2.15E-03 0.0000 0.0000 Pu-240 1.50E+03 S3-012-109B-FJGS-062-SM 2.15E-03 2.15E-03 0.0000 0.0000 Pu-241 3.64E+04 S3-012-109B-FJGS-062-SM 3.31E-01 3.31E-01 0.0000 0.0002 Am-241 1.09E+03 S3-012-109B-FJGS-062-SM 2.43E-02 2.43E-02 0.0000 0.0006 Am-243 1.87E+02 S3-012-109B-FJGS-062-SM 1.08E-02 1.08E-02 0.0001 0.0014 Cm-243 2.88E+02 S3-012-109B-FJGS-062-SM
-2.93E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 S3-012-109B-FJGS-062-SM
-2.93E-03 0.00E+00 0.0000 0.0000 0.0354 H-3 1.75E+04 S3-012-109B-FJGS-063-SM 8.05E-01 8.05E-01 0.0000 0.0012 C-14 2.45E+05 S3-012-109B-FJGS-063-SM 7.84E-01 7.84E-01 0.0000 0.0001 Fe-55 1.02E+07 S3-012-109B-FJGS-063-SM 1.25E-01 1.25E-01 0.0000 0.0000 Ni-59 2.59E+07 S3-012-109B-FJGS-063-SM
-1.52E+00 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 S3-012-109B-FJGS-063-SM
-4.53E-03 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 S3-012-109B-FJGS-063-SM 3.35E-01 3.35E-01 0.0000 0.0000 Sr-90 6.59E+03 S3-012-109B-FJGS-063-SM 5.44E-03 5.44E-03 0.0000 0.0000 Nb-94 2.02E+01 S3-012-109B-FJGS-063-SM
-8.82E-03 0.00E+00 0.0000 0.0000 Tc-99 3.56E+02 S3-012-109B-FJGS-063-SM
-8.51E-01 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 S3-012-109B-FJGS-063-SM 4.97E-02 4.97E-02 0.0009 0.0214 Eu-152 2.84E+01 S3-012-109B-FJGS-063-SM 2.60E-02 2.60E-02 0.0009 0.0229 Eu-154 2.64E+01 S3-012-109B-FJGS-063-SM
-4.92E-02 0.00E+00 0.0000 0.0000 Eu-155 1.12E+03 S3-012-109B-FJGS-063-SM 1.91E-02 1.91E-02 0.0000 0.0004 Np-237 7.99E-01 S3-012-109B-FJGS-063-SM 2.42E-03 2.42E-03 0.0030 0.0757 Pu-238 1.66E+03 S3-012-109B-FJGS-063-SM
-2.97E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 S3-012-109B-FJGS-063-SM
-8.03E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 S3-012-109B-FJGS-063-SM
-8.03E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 S3-012-109B-FJGS-063-SM 2.39E+00 2.39E+00 0.0001 0.0016 Am-241 1.09E+03 S3-012-109B-FJGS-063-SM 4.61E-03 4.61E-03 0.0000 0.0001 Am-243 1.87E+02 S3-012-109B-FJGS-063-SM
-5.93E-03 0.00E+00 0.0000 0.0000 Cm-243 2.88E+02 S3-012-109B-FJGS-063-SM
-5.21E-03 0.00E+00 0.0000 0.0000 Cm-244 2.67E+03 S3-012-109B-FJGS-063-SM
-5.21E-03 0.00E+00 0.0000 0.0000 0.0791 H-3 1.75E+04 S3-012-109B-FJGS-064-SM
-1.87E+00 0.00E+00 0.0000 0.0000 C-14 2.45E+05 S3-012-109B-FJGS-064-SM 2.67E-01 2.67E-01 0.0000 0.0000 Fe-55 1.02E+07 S3-012-109B-FJGS-064-SM
-2.65E+00 0.00E+00 0.0000 0.0000 Ni-59 2.59E+07 S3-012-109B-FJGS-064-SM
-7.47E-01 0.00E+00 0.0000 0.0000 Co-60 1.28E+01 S3-012-109B-FJGS-064-SM
-2.08E-02 0.00E+00 0.0000 0.0000 Ni-63 9.48E+06 S3-012-109B-FJGS-064-SM
-6.69E-01 0.00E+00 0.0000 0.0000 Sr-90 6.59E+03 S3-012-109B-FJGS-064-SM 1.22E-01 1.22E-01 0.0000 0.0005 Nb-94 2.02E+01 S3-012-109B-FJGS-064-SM 4.75E-03 4.75E-03 0.0002 0.0059 Tc-99 3.56E+02 S3-012-109B-FJGS-064-SM
-1.04E+00 0.00E+00 0.0000 0.0000 Cs-137 5.81E+01 S3-012-109B-FJGS-064-SM 8.81E-02 8.81E-02 0.0015 0.0379 Eu-152 2.84E+01 S3-012-109B-FJGS-064-SM
-3.36E-02 0.00E+00 0.0000 0.0000 Eu-154 2.64E+01 S3-012-109B-FJGS-064-SM 1.00E-01 1.00E-01 0.0038 0.0948 Eu-155 1.12E+03 S3-012-109B-FJGS-064-SM 1.72E-02 1.72E-02 0.0000 0.0004 Np-237 7.99E-01 S3-012-109B-FJGS-064-SM
-7.25E-04 0.00E+00 0.0000 0.0000 Pu-238 1.66E+03 S3-012-109B-FJGS-064-SM
-6.00E-03 0.00E+00 0.0000 0.0000 Pu-239 1.49E+03 S3-012-109B-FJGS-064-SM
-1.82E-03 0.00E+00 0.0000 0.0000 Pu-240 1.50E+03 S3-012-109B-FJGS-064-SM
-1.82E-03 0.00E+00 0.0000 0.0000 Pu-241 3.64E+04 S3-012-109B-FJGS-064-SM 1.03E+00 1.03E+00 0.0000 0.0007 Am-241 1.09E+03 S3-012-109B-FJGS-064-SM
-7.38E-03 0.00E+00 0.0000 0.0000 Am-243 1.87E+02 S3-012-109B-FJGS-064-SM 4.84E-03 4.84E-03 0.0000 0.0006 Cm-243 2.88E+02 S3-012-109B-FJGS-064-SM 1.31E-02 1.31E-02 0.0000 0.0011 Cm-244 2.67E+03 S3-012-109B-FJGS-064-SM 1.31E-02 1.31E-02 0.0000 0.0001 0.0089