LA CROSSE BOILING WATER REACTOR FINAL STATUS SURVEY RELEASE RECORD BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 REVISION 1
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 1
PREPARED BY / DATE:
R. F. Yetter III, FSS Specialist REVIEWED BY / DATE:
M. D. Uz, FSS Specialist REVIEWED BY / DATE:
R. Yetter, Director, Radiological Site Closure REVIEWED BY / DATE:
S. Roberts, VP Radiological Programs APPROVED BY / DATE:
S. Zoller, FSS Manager
~
LACROSSESOLUTIONS fla~
Robert F. Yetter III Oct 25 2020 1 :50 PM cosign
~u, Mitchell Uz Oct 27 2020 7:54 AM cosi3n
!RoD.eJd5-.'lfetwt, Robert F. Yetter Oct 27 2020 I 0:59 AM cosign Seualt~~
Sarah Roberts Oct 27 2020 12:27 PM cosign
~--~
Scott G. Zoller
~--:?-aift.:,:,$.,.__
Oct 29 2020 9:30 AM t.:---
.'/
cosign
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 2
TABLE OF CONTENTS
- 1.
EXECUTIVE
SUMMARY
................................................................................................................................. 5
- 2.
SURVEY UNIT DESCRIPTION....................................................................................................................... 5
- 3.
CLASSIFICATION BASIS................................................................................................................................. 6
- 4.
DATA QUALITY OBJECTIVES (DQO).......................................................................................................... 7
- 5.
SURVEY DESIGN............................................................................................................................................... 9
- 6.
SURVEY IMPLEMENTATION...................................................................................................................... 13
- 7.
SURVEY RESULTS.......................................................................................................................................... 15
- 8.
QUALITY CONTROL...................................................................................................................................... 17
- 9.
INVESTIGATIONS AND RESULTS.............................................................................................................. 17
- 10. REMEDIATION AND RESULTS................................................................................................................... 17
- 11. CHANGES FROM THE FINAL STATUS SURVEY PLAN........................................................................ 17
- 12. DATA QUALITY ASSESSMENT (DQA)....................................................................................................... 17
- 13. ANOMALIES..................................................................................................................................................... 18
- 14. CONCLUSION.................................................................................................................................................. 18
- 15. REFERENCES................................................................................................................................................... 18
- 16. ATTACHMENTS.............................................................................................................................................. 19 ATTACHMENT 1 FIGURES AND MAPS............................................................................................................. 20 ATTACHMENT 2 SCAN DATA............................................................................................................................. 24 ATTACHMENT 3 SIGN TEST............................................................................................................................... 26 ATTACHMENT 4 QUALITY CONTROL ASSESSMENT...................................................................................... 28 ATTACHMENT 5 GRAPHICAL PRESENTATIONS............................................................................................. 30 ATTACHMENT 6 LUDLUM 2350-1 DOWNLOAD REPORTS............................................................................ 34
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 3
LIST OF TABLES Table 3-1 Static Measurements for Characterization of Above Grade Buildings............................................... 6 Table 3-2 Summary Statistics for Characterization of Above Grade Buildings.................................................. 6 Table 4 Dose Significant Radionuclides and Mixture for Above Grade Buildings........................................... 8 Table 4 Base Case DCGLs for Above Grade Buildings (DCGLAGB).................................................................. 9 Table 4 Operational DCGLs for Above Grade Buildings (OpDCGLAGB)......................................................... 9 Table 5-1 Survey Unit B3-012-101 Measurement Designations........................................................................... 12 Table 5-2 Investigation Levels................................................................................................................................ 13 Table 5-3 Synopsis of Survey Design...................................................................................................................... 13 Table 7-1 Synopsis of Scan Results........................................................................................................................ 15 Table 7-2 Detector Efficiencies.................................................................................... Error! Bookmark not defined.
Table 7-3 Summary of Random, Judgmental, and QC Static Measurements................................................... 16 Table 7-4 Basic Statistical Properties of Random Measurement Population..................................................... 16 Table 16-1 Survey Unit B3-012-101 Complete Scan Data.................................................................................... 25 Table 16-2 Survey Unit B3-012-101 Sign Test....................................................................................................... 27 Table 16-3 Survey Unit B3-012-101 QC Assessment............................................................................................ 29 LIST OF FIGURES Figure 16 Survey Unit B3-012-101 Random and Judgmental Measurement Locations, 1st Floor Interior.. 21 Figure 16 Survey Unit B3-012-101 Random and Judgmental Measurement Locations, 2nd Floor Interior. 22 Figure 16 Survey Unit B3-012-101 Random and Judgmental Measurement Locations, Outside Walls....... 23 Figure 16 Quantile Plot for Gross Activity......................................................................................................... 31 Figure 16 Histogram for Gross Activity.............................................................................................................. 32 Figure 16 Retrospective Power Curve for Survey Unit B3-012-101................................................................. 33
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 4
LIST OF ACRONYMS AND ABBREVIATIONS ALARA As Low As Reasonably Achievable ASP Alarm Set Point DQA Data Quality Assessment DQO Data Quality Objective DCGL Derived Concentration Guideline Level DCGLAGB Above Grade Building Derived Concentration Guideline Level FSS Final Status Survey GPS Global Positioning System G-3 Genoa 3 HSA Historical Site Assessment IC Insignificant Contributors LACBWR La Crosse Boiling Water Reactor LBGR Lower Bound of the Gray Region LTP License Termination Plan MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual MDC Minimum Detectable Concentration MDCR Minimal Detectable Count Rate OpDCGLAGB Above Grade Building Operational Derived Concentration Guideline Level QAPP Quality Assurance Project Plan QC Quality Control ROC Radionuclides of Concern SOF Sum-of-Fractions TEDE Total Effective Dose Equivalent UBGR Upper Bound of the Gray Region UCL Upper Confidence Limit URS Unconditional Release Survey USNRC United States Nuclear Regulatory Commission
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 5
- 1.
EXECUTIVE
SUMMARY
This Final Status Survey (FSS) Release Record for survey unit B3-012-101, Back-Up Control Center (BCC), has been generated in accordance with LaCrosseSolutions procedure LC-FS-PR-009, Final Status Survey Data Reporting (Reference 1) and satisfies the requirements of Section 5.11 of the La Crosse Boiling Water Reactor License Termination Plan (LACBWR LTP) (Reference 2).
An FSS sample plan for this survey unit was developed in accordance with LaCrosseSolutions procedures LC-FS-PR-015, Final Status Surveys for Structures (Reference 3) and LC-FS-PR-002, Final Status Survey Package Development (Reference 4), the LACBWR LTP, and with guidance from NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (Reference 5).
Survey unit B3-012-101, an above grade building survey unit, has a MARSSIM classification of 3. A survey plan was designed based upon use of the Sign Test as the nonparametric statistical test for compliance. Both the Type I ( ) and Type II ( ) decision error rates were set at 0.05. As a random measurement population, fourteen (14) static beta measurements were acquired from the survey unit. In addition, surface scanning was performed on approximately 11% of the total surface area in the survey unit. The data assessment results for survey unit B3-012-101 indicate that the maximum gross activity among random measurements is equal to 596 dpm/100 cm2, which is 18.86% of the Adjusted Gross Operational Derived Concentration Guideline Level (DCGL) for above grade buildings (see Section 5 of this release record for the calculations of adjusted gross DCGLs). Therefore, the null hypothesis of the Sign test is rejected and survey unit B3-012-101 is acceptable for unrestricted release. The mean gross activity among random measurements is equal to 240 dpm/100 cm2, which is 1.22% of the Adjusted Gross Base Case DCGL. Multiplying this fraction by 25 mrem/yr results in a dose for the survey unit of 0.3038 mrem/yr.
- 2.
SURVEY UNIT DESCRIPTION Survey unit B3-012-101 is an impacted Class 3 above grade building survey unit. The survey unit consists of the interior and exterior surfaces of the BCC, which was utilized for the Genoa 3 (G-3) Power Plant. The BCC is a two-story building measuring 20.5 m long by 7.4 m wide by 7.7 m high, which equates to a total surface area of 1710 m2. Refer to of this report for figures and maps depicting survey unit B3-012-101.
~
LACROSSESOLUTIONS a
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 6
- 3.
CLASSIFICATION BASIS Based on the La Crosse Boiling Water Reactor Historical Site Assessment (HSA)
(Reference 6), survey unit B3-012-101 was identified as a Class 3 structure survey unit. The following summarizes the results of the characterization surveys for seven (7) of the above grade buildings to be left on-site upon termination of the license.
The characterization surveys for the above grade buildings were conducted between November 8, 2016, and November 18, 2016. In total, fifty-six (56) static beta measurements were collected in the buildings (eight [8] in each of seven [7] buildings). No measurements exceeded their respective action levels. A summary of the static measurements is presented in Table 3-1. The summary statistics for the characterization data are provided in Table 3-2.
Table 3-1 Static Measurements for Characterization of Above Grade Buildings Static Beta Measurements (dpm/100 cm2)
LACBWR Crib House G-3 Crib House Back-Up Control Center Transmission Sub-Station Switch House Barge Wash Break Room G-1 Crib House Security Station 313 1,264 588 213 0
751 0
13 13 363 226 38 0
150 0
38 0
0 0
0 0
1,702 26 88 889 0
1,514 0
138 0
0 376 0
0 38 0
450 0
238 0
551 100 0
100 0
0 163 438 225 0
2,203 651 0
0 1,089 13 Table 3-2 Summary Statistics for Characterization of Above Grade Buildings Mean Median Minimum Maximum Standard Deviation (dpm/100 cm2)
(dpm/100 cm2)
(dpm/100 cm2)
(dpm/100 cm2)
(dpm/100 cm2) 267 32 0
2,203 473 Based upon review of the historical information, the results of the characterization survey data, and completion of a final Survey Unit Classification Worksheet, the correct final classification of survey unit B3-012-101 was determined to be Class 3.
~
LACROSSESOLUTIONS I
I I
I
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 7
- 4.
DATA QUALITY OBJECTIVES (DQO)
FSS planning and design relies on a properly executed Data Quality Objective (DQO) process to ensure, through compliance with explicitly defined inputs and boundaries, that the primary objective of the survey is satisfied. The DQO process, utilized in accordance with MARSSIM, is described in the LACBWR LTP. The appropriate design for a given survey was developed using the DQO process as outlined in Appendix D of MARSSIM.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS sample plan.
The primary objective of the FSS sample plan is to demonstrate that the level of residual radioactivity in survey unit B3-012-101 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
EnergySolutions TSD RS-TD-313196-001, Radionuclides of Concern during LACBWR Decommissioning (Reference 7) established the basis for an initial suite of potential ROC for decommissioning. Insignificant contributors (IC) were determined consistent with the guidance contained in Section 3.3 of NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance Characterization, Survey, and Determination of Radiological Criteria, Final Report (Reference 8). In all soil and concrete scenarios, Cs-137, Co-60, Sr-90, Eu-152 and Eu-154 contribute nearly 100% of the total dose. The remaining radionuclides were designated as IC and were eliminated from further detailed evaluation. Therefore, the final ROCs for LACBWR above grade buildings, soil, basement concrete, and buried piping are Cs-137, Co-60, Sr-90, Eu-152 and Eu-154.
The LTP, Section 6.14.1, discusses the process used to derive the ROC for the decommissioning of LACBWR, including the elimination of IC from the initial suite.
Table 4-1 presents the ROC for the decommissioning of above grade buildings at LACBWR and the normalized mixture fractions based on the radionuclide mixture.
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 8
Table 4 Dose Significant Radionuclides and Mixture for Above Grade Buildings Radionuclide Fraction of Total Activity (normalized)(1)
Co-60 0.0644 Sr-90 0.0981 Cs-137 0.829 Eu-152 0.00549 Eu-154 0.00281 (1) Based on maximum percent of total activity from Table 22 of RS-TD-313196-001, normalized to one for the dose significant radionuclides.
The LTP, Section 5.2, states that each radionuclide-specific Base Case DCGL is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem/yr to an Average Member of the Critical Group. To ensure that the summation of dose from each source term is 25 mrem/yr or less after all FSS is completed, the Base Case DCGLs are reduced based on an expected, or a priori, fraction of the 25 mrem/yr dose limit from each source term. The reduced DCGLs (i.e.,
) can be related to the Base Case DCGLs as an expected fraction of dose based on an a priori assessment of what the expected dose should be based on the results of site characterization, process knowledge, and the extent of planned remediation. The Operational DCGL is then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigations levels, etc.). Details of the Operational DCGLs derived for each dose component and the basis for the applied a priori dose fractions are provided in LC-FS-TSD-002, Operational Derived Concentration Guideline Levels for Final Status Survey (Reference 9).
At LACBWR, compliance is demonstrated through the summation of dose from five (5) distinct source terms (i.e., basements, soils, buried pipe, above grade buildings, and groundwater) for the end-state. When applied to above grade buildings, the DCGLs are expressed in units of activity per surface area (dpm/100 cm2).
The Screening Values in NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance Characterization, Survey, and Determination of Radiological Criteria, Final Report, Table H-1, are applied to the FSS of above grade buildings. The Table H-1 Screening Values are presented as Base Case DCGLs (equivalent to 25 mrem/yr) and are reproduced in Table 4-2 below.
~
LACROSSESOLUTIONS "Operational" DCGLs
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 9
Table 4 Base Case DCGLs for Above Grade Buildings (DCGLAGB)
Radionuclide DCGLAGB (dpm/100cm2)
Co-60 7,100 Sr-90 8,700 Cs-137 28,000 Eu-152 12,700 Eu-154 11,500 The Operational DCGLs are then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigation levels, etc.). The Operational DCGLs for the unrestricted release of above grade buildings are provided in Table 4-3.
Table 4 Operational DCGLs for Above Grade Buildings (OpDCGLAGB)
Radionuclide OpDCGLAGB (dpm/100cm2)
Co-60 1,136 Sr-90 1,392 Cs-137 4,480 Eu-152 2,032 Eu-154 1,840 Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the Operational DCGL. Survey instrument response checks were required prior to issuance and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data. The minimum acceptable MDC for measurements obtained using field instruments was 50% of the applicable Operational DCGL.
- 5.
SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey unit and nature of the hazards. Guidance for preparing FSS plans is provided in procedures LC-FS-PR-015, Final Status Surveys for Structures, and LC-FS-PR-002, Final Status Survey Package Development.
For the FSS of above grade buildings, Adjusted Gross DCGLs are calculated. This is done
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 10 because radionuclide-specific data is not acquired with static measurements. The equation for calculating the Adjusted Gross DCGL is as follows:
Equation 1 Where:
DCGLAG
= Adjusted Gross DCGL in units of dpm/100 cm2 DCGLi
= Gross DCGL for detectable radionuclide in units of dpm/100 cm2 fi
= Mixture fraction of detectable radionuclides Using Equation 1, and values within Tables 4-1 and 4-3, the Adjusted Gross Operational DCGL was calculated as follows:
Equation 2 The Adjusted Gross Operational DCGL was calculated as 3,160 dpm/100 cm2. The action level for survey unit B3-012-101 was equivalent to 50% of the Adjusted Gross Operational DCGL, or 1,580 dpm/100 cm2.
Using Equation 1, and values in Tables 4-1 and 4-2, the Adjusted Gross Base Case DCGL was calculated as follows:
Equation 3
~
LACROSSESOLUTIONS 1
DCGLAG = [( fi ) ( fz
)
(
f;,
)]
DCGL1 + DCGL2 +... DCGLi OpDCGLAG 1
=---------------------------------,----------~
[( 0.0644
) + ( 0.0981
) + (
0.829
) + ( 0.00549
) + ( 0.00281
)]
1136(co-60) 1392(sr-90) 4480(cs-137) 2032(Eu-152) 1840(Eu-154)
= 3160 dpm/100 cm2 BcDCGLAG 1
=-----------------------------
[( 0.0644
) + ( 0.0981
) + (
0.829
) + (
0.00549
) + (
0.00281
)]
7100(co-60) 8700(sr-90) 28000(cs-l37) 12700(Eu-l52) 11500(Eu-is4)
= 19751 dpm/100 cm2
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 11 The Adjusted Gross Base Case DCGL was calculated as 19,751 dpm/100 cm2. The mean activity from the FSS random measurements is compared to the Adjusted Gross Base Case DCGL, and the dose contribution from the survey unit is calculated.
The Sign test was selected as the non-parametric statistical test for compliance with the release criteria. The number of measurements for use with the Sign test was determined in accordance with procedures LC-FS-PR-002 and LC-FS-PR-015.
the survey unit data set is Region (UBGR), or the DCGL, minus the Lower Bound of the Gray Region (LBGR),
one (1) and three (3). The largest value the three (3). If the calculated value of three (3), an adjusted value of three (3)
B3-012-101, based on the amalgamated gross measurement data from characterization of the LACBWR above grade buildings to remain at license termination, was calculated as follows:
Equation 4
=
1580/473
=
3.34 As the calculated relative shift was greater than three (3), a value of three (3) was used as I error (i.e., value) and the Type II error (i.e., value) was set at 0.05. The sample size from Table 5.5 of MARSSIM that equates to the Type I and Type II error of 0.05 for use with the Sign test is an N value of fourteen (14).
A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10CFR20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.
As the survey unit was designated Class 3, measurement locations were selected at random.
The random locations of the static measurements were selected using Visual Sample Plan (VSP). Input parameters included the use of survey unit drawings and the random sampling tool set with a predetermined number (14) of samples. The random measurement locations were identified in the field using dimension parameters provided on the survey unit map (see Attachment 1). Table 5-1 lists the random, judgmental, and QC measurements collected for FSS of survey unit B3-012-101.
~
LACROSSESOLUTIONS The relative shift (t:Jcr) for defined as shift(~), which is the Upper Boundary of the Gray divided by sigma ( cr ), which is the standard deviation of the data set used for survey design.
The optimal value for t:Jcr should range between
~/cr can have is t:Jcr exceeds will be used for f:Jcr. The ~/cr for survey unit
~/cr the adjusted t:Jcr. Both the Type a
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 12 Table 5-1 Survey Unit B3-012-101 Measurement Designations Measurement ID B3-012-101-FRWC-001-BD B3-012-101-FRWW-002-BD B3-012-101-FRWC-003-BD B3-012-101-FRFC-004-BD B3-012-101-FRFM-005-BD B3-012-101-FRFM-006-BD B3-012-101-FRWC-007-BD B3-012-101-FRFM-008-BD B3-012-101-FRWW-009-BD B3-012-101-FRWC-010-BD B3-012-101-FRWC-011-BD B3-012-101-FRWC-012-BD B3-012-101-FRWW-013-BD B3-012-101-FRFM-014-BD B3-012-101-FJWC-015-BD B3-012-101-FQFM-014-BD The implementation of quality control measures, as referenced in LTP, Section 5.9, and LaCrosseSolutions LC-QA-PN-001, Final Status Survey Quality Assurance Project Plan (QAPP) (Reference 10), includes the collection of a replicate measurement on 5% of the measurements collected in a survey unit, with the locations selected at random. One (1) replicate measurement, B3-012-101-FQFM-014-BD, was selected at random for the QC replicate measurement analysis for the FSS of this survey unit.
The LTP, Section 5.6.4.4 and Table 5-15, specifies that for Class 3 structure survey units, surface scans will be performed on a judgmental percentage of the surface area in the survey unit. Typically, surface scans would be performed judgmentally on areas with the greatest potential for contamination. In the absence of any peculiar features identified during the survey unit walkdown that would indicate contamination, and because historical radiological information did not provide sufficient evidence for increased contamination potential, the survey design elected that scanning be performed at random. This allowed for the even distribution of scan surveys around the entire survey unit. For survey unit B3-012-101, 10% scan coverage was selected, which equates to 171 m2. Fourteen (14) scan areas (ten [10] 12.4 m2 scan areas and four [4] 12.25 m2 scan areas), covering 173 m2 of the survey unit (more than the required minimum), were established. Refer to Attachment 1 for figures and maps depicting the measurement and scan locations in survey unit B3-012-101.
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 13 For this Class 3 structure direct measurement results are those levels specified in the LTP, Table 5-16, and are reproduced below in Table 5-2.
Table 5-2 Investigation Levels Classification Scan Investigation Levels Direct Investigation Levels Class 3
>Operational DCGL or >MDCscan if MDCscan is greater than Operational DCGL
>50% Operational DCGL Table 5-3 provides a synopsis of the survey design for survey unit B3-012-101.
Table 5-3 Synopsis of Survey Design Feature Design Criteria Basis Survey Unit Surface Area 1710 m2 Building Dimensions Number of Random Measurements (N) 14 473 UBGR = 3,160 LBGR = 1,580 Type I & II error = 0.05 MARSSIM Table 5.5 DCGL/Action Level 3,160 dpm/100 cm2 Adjusted Gross Operational DCGL (Equation 2)
Direct Investigation Level
>50% Operational DCGL (1,580 dpm/100 cm2)
LTP Table 5-16 Scan Investigation Level
>Operational DCGL or >MDCscan LTP Table 5-16 Scan Areal Coverage 173 m2 or ~10% areal coverage 185 m2 (with 1 judgmental grid) or ~11%
LTP Table 5-15 Actual Scan Coverage Judgmental Measurements 1
Per Survey Design QC 1 replicate measurement selected at random location LTP Section 5.9
- 6.
SURVEY IMPLEMENTATION For survey unit B3-012-101, compliance with the unrestricted release criteria was demonstrated through a combination of surface scanning and surface static measurements with a Ludlum Model 44-116 beta/gamma detector.
~
LACROSSESOLUTIONS survey unit, the "Investigation Levels" for area scanning and
- CJ=
- Nu= 3 (adjusted)
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 14 An FSS Supervisor performed a visual inspection and walk-down of the survey unit during the Unconditional Release Survey (URS) that was performed prior to FSS. The purpose of the walk-down was to assess the physical condition of the survey unit, evaluate access points and travel paths, and identify potentially hazardous conditions. At the time of FSS, the interior of the building was dry, and the exterior (in areas not subject to random surveys) was sparsely covered (nearest to the ground) with ice. The grounds around the building were muddy and partially covered in snow, making travel paths a safety concern. No conditions prohibited the proper collection of static and scan measurements.
FSS field activities were conducted under the FSS Sample Plan, which included DQOs, survey design, detailed FSS instructions, job safety analysis, and related procedures for reference. FSS field activities were projected to take four (4) working days to complete.
Daily briefings were conducted to discuss the expectations for job performance and to review safety aspects of the job.
was used to document field activities and other information pertaining to the performance of the FSS. FSS field activities commenced on February 20, 2019, and were concluded on the same day.
A total of fifteen (15) different scan areas (fourteen [14] random and one [1] judgmental),
constituting an areal coverage of 185 m2, were scanned using a Ludlum 2350-1 paired with a Ludlum Model 44-116 detector (125 cm2 detector area). The background was established as the average of five (5) 1-minute static measurements, while maintaining the detector waist high with the detector face pointed away from the surface of interest. In survey unit B3-012-101, background ranged from 217 cpm up to 219 cpm.
All designated scan areas were scanned using a Ludlum 2350-1 paired with a Model 44-116 beta/gamma detector operated in the rate-meter mode and using audio response. The probe was positioned as close to the surface as possible and was moved at a scan speed of approximately one (1) detector width per second. Scan MDC was sufficient to detect residual radioactivity at the action level of 1,580 dpm/100cm2 (i.e., 50% of Adjusted Gross Operational DCGL). Complete scan results are provided in Attachment 2.
The fourteen (14) random static measurement locations were marked based on the dimensions provided on the survey map. One (1) judgmental measurement location was selected and marked as per the sample plan. Using the Ludlum 2350-1 paired with a Model 44-116 detector, a 1-minute static measurement was acquired at each designated random and judgmental survey location.
The implementation of survey specific QC measures included the collection of one (1) replicate static measurement (B3-012-101-FQFM-014-BD) for QC analysis.
~
LACROSSESOLUTIONS A "Field Log"
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 15
- 7.
SURVEY RESULTS All areas identified in the FSS plan were scanned for elevated radiation levels. No alarms were produced during the scanning of survey unit B3-012-101. Table 7-1 provides an overview of the scan results. Complete scan results are provided in Attachment 2.
Table 7-1 Synopsis of Scan Results Scan Area Highest Logged Reading Action Level(1)
- of Scan Alarms Investigation Measurements (cpm)
(cpm) 1 395 439 0
0 2
321 443 0
0 3
375 443 0
0 4
337 443 0
0 5
344 443 0
0 6
350 443 0
0 7
391 439 0
0 8
349 443 0
0 9
329 443 0
0 10 330 439 0
0 11 400 439 0
0 12 393 439 0
0 13 231 443 0
0 14 295 443 0
0 15 J 362 439 0
0 14 QC 429 439 0
0 (1) Action Level based on the average background plus MDCRSurveyor.
Background was subtracted from all measurements, then converted from cpm to dpm/100 cm2 (net cpm divided by detector efficiency) for direct comparison to the Adjusted Gross DCGLs. Table 7-2 below presents the detector efficiencies used for conversions. A summary of the results for the fourteen (14) random static measurements, one (1) judgmental static measurement, and one (1) QC static measurement is provided in Table 7-3. The basic statistics for the random measurement population are summarized in Table 7-4.
~
LACROSSESOLUTIONS MDCRsurueyor = (1.38 JBackground (fa) 60)/v'0. 5
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 16 Table 7-2 Detector Efficiencies44-116 Detector #
Efficiency (c/d)
PR 357439 0.2381 PR 357009 0.2047 Table 7-3 Summary of Random, Judgmental, and QC Static Measurements Measurement ID Gross Activity Fraction of Adjusted Gross OpDCGL (dpm/100 cm2)
B3-012-101-FRWC-001-BD 332 0.1050 B3-012-101-FRWW-002-BD 68 0.0216 B3-012-101-FRWC-003-BD 298 0.0943 B3-012-101-FRFC-004-BD 596 0.1886 B3-012-101-FRFM-005-BD 78 0.0247 B3-012-101-FRFM-006-BD 0
0.0000 B3-012-101-FRWC-007-BD 231 0.0731 B3-012-101-FRFM-008-BD 547 0.1731 B3-012-101-FRWW-009-BD 68 0.0216 B3-012-101-FRWC-010-BD 231 0.0731 B3-012-101-FRWC-011-BD 168 0.0532 B3-012-101-FRWC-012-BD 332 0.1050 B3-012-101-FRWW-013-BD 0
0.0000 B3-012-101-FRFM-014-BD 410 0.1299 B3-012-101-FJWC-015-BD 286 0.0904 B3-012-101-FQFM-014-BD 147 0.0465 Table 7-4 Basic Statistical Properties of Random Measurement Population Mean Median Max Min Std. Dev.
Adjusted Gross BcDCGL Mean Adjusted Gross BcDCGL Fraction Dose (dpm/100cm2)
(dpm/100cm2)
(dpm/100cm2)
(dpm/100cm2)
(dpm/100cm2)
(dpm/100cm2) 240 231 596 0
191 19,751 0.0122 0.3038
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 17 The mean activity from random static measurements was divided by the Adjusted Gross Base Case DCGL to derive a mean fraction. The mean fraction was then multiplied by twenty-five (25) mrem/yr to derive the dose attributed to the survey unit. For survey unit B3-012-101, the dose is 0.3038 mrem/yr.
- 8.
QUALITY CONTROL The implementation of survey specific QC measures included the collection of one (1) replicate static measurement (B3-012-101-FQFM-014-BD) for QC analysis. The acceptance criterion for replicate static measurements is that the same conclusion is reached for each measurement. The acceptance criterion is satisfied if the replicate measurement is within 20% of the standard measurement. In cases where the replicate measurement is not within 20% of the standard measurement, but both measurements are below the Operational DCGL as well as the static MDC, there is an acceptable agreement. The QC replicate measurement for survey unit B3-012-101 did not fall within the 20% criteria; however, both the standard and replicate measurements were well below the Operational DCGL.
Therefore, there is an acceptable agreement between standard and replicate results. Refer to for the QC analysis results.
- 9.
INVESTIGATIONS AND RESULTS No investigations were performed during the performance or analyses of the survey.
- 10.
REMEDIATION AND RESULTS No radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Chapter 4 of the LTP determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in above grade buildings was ALARA.
- 11.
CHANGES FROM THE FINAL STATUS SURVEY PLAN There were no addendums to the FSS plan.
- 12.
DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with LC-FS-PR-008, Final Status Survey Data Assessment (Reference 11), for completeness and consistency.
Documentation was complete and legible. Scan surveys and the collection of static measurements were consistent with the DQOs and were sufficient to ensure that the survey
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 18 unit was properly designated as Class 3. The survey design had adequate power as indicated by the Retrospective Power Curve (see Attachment 5).
The measurement results indicated that all measurements were less than 50% of the Adjusted Gross Operational DCGL.
Although MARSSIM states that the Sign test need not be performed in the instance that no measurements exceed the DCGL, the test was conducted to demonstrate coherence to the statistical principles of the DQO process. The Sign test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign test results clearly demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values of the data were well below the Adjusted Gross Operational DCGL. Also, the retrospective power curve shows that a sufficient number of measurements were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.
The survey unit data is presented graphically through a frequency plot and quantile plot. All graphical presentations are provided in Attachment 5.
- 13.
ANOMALIES No anomalies were observed during the performance or analyses of the survey.
- 14.
CONCLUSION Survey unit B3-012-101 has met the DQOs of the FSS plan. The ALARA criteria as specified in Chapter 4 of the LTP were achieved.
The sample data passed the Sign test. The null hypothesis was rejected. The Retrospective Power Curve showed that adequate power was achieved. The survey unit is properly classified as Class 3. Therefore, in accordance with the LTP, Section 5.11, the survey unit meets the release criteria.
The dose contribution from survey unit B3-012-101 is 0.3038 mrem/yr TEDE, based on the mean activity of measurements used for non-parametric statistical sampling.
Survey unit B3-012-101 is acceptable for unrestricted release.
- 15.
REFERENCES
- 1. LC-FS-PR-009, Final Status Survey Data Reporting
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 19
- 2. La Crosse Boiling Water Reactor License Termination Plan
- 3. LC-FS-PR-015, Final Status Surveys for Structures
- 4. LC-FS-PR-002, Final Status Survey Package Development
- 5. NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM)
- 6. La Crosse Boiling Water Reactor Historical Site Assessment
- 7. RS-TD-313196-001, Radionuclides of Concern During LACBWR Decommissioning
- 8. NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance Characterization, Survey, and Determination of Radiological Criteria, Final Report
- 9. LC-FS-TSD-002, Operational Derived Concentration Guideline Levels for Final Status Survey
- 10. LC-QA-PN-001, Final Status Survey Quality Assurance Project Plan
- 11. LC-FS-PR-008, Final Status Survey Data Assessment
- 16.
ATTACHMENTS Figures and Maps Scan Data Sign Test Quality Control Assessment Graphical Presentations Ludlum 2350-1 Download Reports
~
LACROSSESOLUTIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 20 ATTACHMENT 1 FIGURES AND MAPS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 21 Figure 16 Survey Unit B3-012-101 Random and Judgmental Measurement Locations, 1st Floor Interior
'101 -
,:::=
LACROSSESOLUTJONS WALL CEILING 2.90 08 1B FLOOR 1C 1A ROOF TITLE: Backup Control Center - 1st Floor Interior - Sample Locations 1E 1.21 DATE: 02/25/2019 03 DWG # 17013101.e N
E 1.40_r
~
04
,1,
__j 2.14 3.001--
w
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 22 Figure 16 Survey Unit B3-012-101 Random and Judgmental Measurement Locations, 2nd Floor Interior
~
LACROSSESOLUTJONS WALL CEILING FLOOR ROOF TITLE: Backup Control Center - 2nd Floor Interior - Sample Locations DATE: 02/25/2019 DWG # 17013101.e N
1.30-1--
r 1.95 14-QC 2F 2E I
11 0.881
~
=ZIONSOLUTIONSu.c-
,.,.e-v,~COnlpar,r 2D 05 1.85 7
4.00 1--
2G Ir 08 02 0.90 T
-l
-2.37
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 23 Figure 16 Survey Unit B3-012-101 Random and Judgmental Measurement Locations, Outside Walls
~
=ZIONSOLUTIONSu.c-
,.,.e-v,~COnlpar,r
~
LACROSSESOLUTIONS WALL CEILING FLOOR 2.70 1.00 3.~
1-- 6.11 5.00 ROOF f
01 TITLE: Backup Control 7.01 Center - Outside Walls -
15 (BIASED) 2.00 Sample Locations I
5.55 DATE: 02/25/2019 DWG # 17013101.e l
11
~
0.92 10 1.00 1,
07
--I 2.03 1.00 8
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 24 ATTACHMENT 2 SCAN DATA
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 25 Table 16-1 Survey Unit B3-012-101 Complete Scan Data Detector Type Detector ID M2350-1 ID Location Scan Logged Result Avg
Background
Action Level(1)
Scan Alarms (cpm)
(cpm)
(cpm)44-116 357439 325261 1
395 217 439 0
44-116 357009 325246 2
321 219 443 0
44-116 357009 325246 3
375 219 443 0
44-116 357009 325246 4
337 219 443 0
44-116 357009 325246 5
344 219 443 0
44-116 357009 325246 6
350 219 443 0
44-116 357439 325261 7
391 217 439 0
44-116 357009 325246 8
349 219 443 0
44-116 357009 325246 9
329 219 443 0
44-116 357439 325261 10 330 217 439 0
44-116 357439 325261 11 400 217 439 0
44-116 357439 325261 12 393 217 439 0
44-116 357009 325246 13 231 219 443 0
44-116 357009 325246 14 295 219 443 0
44-116 357439 325261 15 J 362 217 439 0
44-116 357439 325261 14 QC 429 217 439 0
(1) Action Level based on the average background plus MDCRSurveyor.
IOL MDCRsurveyor = (1. 38 JBackground (fa) 60)/',/0. 5
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 26 ATTACHMENT 3 SIGN TEST
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 27 Table 16-2 Survey Unit B3-012-101 Sign Test SOF 1-WS Sign (WS) 1 0.1050 0.90
+1 2
0.0216 0.98
+1 3
0.0943 0.91
+1 4
0.1886 0.81
+1 5
0.0247 0.98
+1 6
0.0000 1.00
+1 7
0.0731 0.93
+1 8
0.1731 0.83
+1 9
0.0216 0.98
+1 10 0.0731 0.93
+1 11 0.0532 0.95
+1 12 0.1050 0.90
+1 13 0.0000 1.00
+1 14 0.1299 0.87
+1 Number of positive differences (S+)
14 Critical Value 10 Survey Unit Meets the Acceptance Criteria
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 28 ATTACHMENT 4 QUALITY CONTROL ASSESSMENT
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 29 Table 16-3 Survey Unit B3-012-101 QC Assessment Standard Activity (dpm/100cm2)
-20%
+20%
Comparison Activity (dpm/100cm2)
Within 20%
B3-012-101-FRFM-014-BD 410 328 492 B3-012-101-FQFM-014-BD 147 N
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 30 ATTACHMENT 5 GRAPHICAL PRESENTATIONS
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 31 Figure 16 Quantile Plot for Gross Activity
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 32 Figure 16 Histogram for Gross Activity
~
2 w
4
- , 3 a
w
- u.
0 99 199 298 397 497 596 UPPER END VALUE (DPM/100CM 2)
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 33 Figure 16 Retrospective Power Curve for Survey Unit B3-012-101 Pro,b,.. t a
e 1.0 I
I I
0.8, I
I 0.6 I
0.4 +---+--+---+-t---+1----t-+----t---t--t-1------l--t--t---+---+----
I 0.2 ------1 ---------
I 0.0' +---+--+---+-l---+-....,._--+~-1---i,;:i' ~........ ~+--~-+----1------
110~
3 J~
50%
1c)%
9)~1 )0'J10%
130%
1'-%
I e,
ofD 1GL)
FSS RELEASE RECORD REVISION 1 BACK-UP CONTROL CENTER SURVEY UNIT B3-012-101 34 ATTACHMENT 6 LUDLUM 2350-1 DOWNLOAD REPORTS
Probe Serial Sample Survey Unit D=Direct Source Detector Logged Units Count Logging Alarm=l No Inst Serial Tech Model Number Number Grid Location S=Scan BKG Check Date /Time Setup Reading (cpm)
Time Mode(min)
Alarm=O Number Name 44-116 357439 0
BD PRBKG 2/20/2019 6:22 1
219 c
60 1
0 325261 LMC 44-116 357439 1
BD PRCHK 2/20/2019 6:24 1
2668 c
60 1
1 325261 LMC 44-116 357439 2
B3101 KLOBK BO 2/20/2019 12:41 1
227 c
60 1
0 325261 LMC 44-116 357439 3
83101 KLDBK 8D 2/20/2019 12:42 1
224 c
60 1
0 325261 LMC 44-116 357439 4
B3101 KLDBK BD 2/20/2019 12:43 1
223 c
60 1
0 325261 LMC 44-116 357439 5
B3101 KLOBK BO 2/20/2019 12:44 1
216 c
60 1
0 325261 LMC 44-116 357439 6
B3101 KLOBK BO
~
2/20/201912:45 1
193 c
60 1
0 325261 LMC 44-116 357439 7
83101 7
BS 2/20/2019 13:07 1
391 c
O O
O 32S261 LMC 44-116 357439 8
B3101 7
BD 2/20/201913:09 1
272 c
60 1
0 325261 LMC 44-116 357439 9
B3101 10 BS 2/20/2019 13:31 1
330 c
O O
O 32S261 LMC 44-116 357439 10 B3101 10 BD 2/20/2019 13:33 1
272 c
60 1
0 325261 LMC 44-116 357439 11 B3101 12 BS 2/20/2019 13:54 1
393 c
O O
O 325261 LMC 44-116 357439 12 B3101 12 BD 2/20/2019 13:56 1
296 c
60 1
0 325261 LMC 44-116 357439 13 B3101 1
BS
-~ * ~.
2/20/201914:31 1
395 c
O O
O 325261 LMC 44-116 357439 14 B3101 1
BO 2/20/2019 14:32 1
296 c
60 1
0 325261 LMC 44-116 357439 17 B3101 15 BS 2/20/201914:57 1
362 c
O O
O 325261 LMC 44-116 357439 18 B3101 15 BO 2/20/2019 14:58 1
285 c
60 1
0 325261 LMC 44-116 357439 19 B3101 11 BS
.. * ~
2/20/2019 15:23 1
400 c
O O
O 325261 LMC 44-116 357439 20 83101 11 BO 2/20/201915:26 1
257 c
60 1
0 325261 LMC 44-116 357439 22 B3101 14QC BS
~
2/20/2019 15:49 1
429 c
O O
O 325261 LMC 44-116 357439 23 B3101 14QC BO 2/20/2019 15:50 1
252 c
60 1
0 325261 LMC 44-116 357439 24 BO PSBKG 2/20/2019 15:58 1
237 c
60 1
0 325261 LMC 44-116 357439 25 BD PSCHK 2/20/201916:02 1
2663 c
60 1
1 325261 LMC
Probe Serial Sample Survey Unit D=Direct Source Detector Logged Units Count Logging Alarm=l No Inst Serial Tech Model Number Number Grid Location S=Scan BKG Check Date/ Time Setup Reading (cpm}
Time Mode(min)
Alarm=O Number Name 44-116 357009 0
BD PRBKG 2/20/2019 6:19 2
153 C
60 1
0 325246 SB 44-116 357009 1
BD PRCHK 2/20/2019 6:26 2
2432 C
60 1
1 325246 SB 44-116 357009 2
B3101 FLDBK 8D 2/20/2019 8:26 2
217 C
60 1
0 325246 SB 44-116 357009 3
B3101 FLDBK BD 2/20/2019 8:27 2
224 C
60 1
0 325246 SB 44-116 357009 4
B3101 FLDBK BD 2/20/2019 8:29 2
203 C
60 1
0 325246 SB 44-116 357009 5
83101 FLDBK BD 2/20/2019 8:31 2
225 C
60 1
0 325246 SB 44-116 357009 6
B3101 FLDBK BD 2/20/2019 8:34 2
228 C
60 1
0 325246 SB 44-116 357009 7
B3101 4
BS r
I 2/20/2019 9:01 2
337 C
0 0
0 325246 SB 44-116 357009 8
BD PRBKG 2/20/2019 9:27 2
198 C
60 1
0 325246 SB 44-116 357009 10 BD PRCHK 2/20/2019 9:33 2
2442 C
60 1
1 325246 SB 44-116 357009 11 B3101 4
BD 2/20/2019 9:54 2
341 C
60 1
0 325246 SB 44-116 357009 12 B3101 6
BS 2/20/2019 10:12 2
350 C
0 0
0 325246 SB 44-116 357009 13 B3101 6
BD 2/20/2019 10:16 2
219 C
60 1
0 325246 SB 44-116 357009 14 B3101 2
BS 2/20/2019 10:34 2
321 C
0 0
0 325246 SB 44-116 357009 15 B3101 2
BD 2/20/2019 10:36 2
233 C
60 1
0 325246 SB 44-116 357009 16 B3101 9
BS f
2/20/2019 10:54 2
329 C
0 0
0 325246 SB 44-116 357009 17 B3101 9
BO 2/20/2019 10:56 2
233 C
60 1
0 325246 SB 44-116 357009 18 83101 s
BS 2/20/2019 12:20 2
344 C
0 0
0 325246 SB 44-116 357009 20 B3101 5
BD 2/20/2019 12:23 2
235 C
60 1
0 325246 SB 44-116 357009 21 B3101 13 BS 2/20/2019 12:47 2
231 C
0 0
0 325246 SB 44-116 357009 22 B3101 13 BO "1
r 2/20/2019 12:50 2
196 C
60 1
0 325246 SB 44-116 357009 23 B3101 3
BS
,r ::
I f:_
2/20/2019 13:10 2
375 C
0 0
0 325246 SB 44-116 357009 24 83101 3
BO
- .-:,_~~-:~,-
Ji;*;;~..::*_.
2/20/201913:12 2
280 C
60 1
0 325246 SB 44-116 357009 25 83101 8
BS if.ct.~-'.:iil.~ ~ ~-rt
2/20/201913:37 2
349 C
0 0
0 325246 SB 44-116 357009 27 83101 8
BO
- !:*:. ~-~--r-;.:rJ l** ~~'H.
2/20/2019 13:39 2
331 C
60 1
0 325246 SB 44-116 357009 28 83101 14 BS
... --: : f~;:*f~ *-
~ i ~~>,::.t:-
2/20/2019 14:36 2
295 C
0 0
0 325246 SB 44-116 357009 29 B3101 14 BD
! *~t.,'*:~~*..
2/20/2019 14:39 2
303 C
60 1
0 325246 SB 44-116 357009 30 BD PSBKG
..-:~, *~*-: *.
2/20/2019 15:16 2
186 C
60 1
0 325246 SB 44-116 357009 31 8D PSCHK 2/20/2019 15:19 2
2433 C
60 1
1 325246 SB