ML20352A246

From kanterella
Jump to navigation Jump to search
Response to Request for Additional Information Re Revised Final Status Survey Final Reports, S1-011-102 Release Record Revision 1, Final, Circulating Water Discharge Pipe
ML20352A246
Person / Time
Site: La Crosse  File:Dairyland Power Cooperative icon.png
(DPR-045)
Issue date: 11/02/2020
From:
La CrosseSolutions
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20356A041 List:
References
LC-2020-0023
Download: ML20352A246 (68)


Text

LA CROSSE BOILING WATER REACTOR FINAL STATUS SURVEY RELEASE RECORD CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 REVISION 1

~:::. ::-

~ ---

LACROSSE SOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 1

PREPARED BY / DATE:

R. F. Yetter III, FSS Specialist REVIEWED BY / DATE:

M. D. Uz, FSS Specialist REVIEWED BY / DATE:

R. Yetter, Director, Radiological Site Closure REVIEWED BY / DATE:

S. Roberts, VP Radiological Programs APPROVED BY / DATE:

S. Zoller, FSS Manager

~u, 9lol,.e,dg,.'lj-elwt

~

LACROSSESOLUTIONS Robert F. Yetter III Oct 25 2020 1 :56 PM Mitchell Uz Oct 27 2020 8:02 AM Robert F. Yetter Oct 27 2020 11 :07 AM Sarah Roberts Oct 27 2020 12:57 PM Scott G. Zoller Oct 29 2020 9:38 AM cosign cosi n cosign cosign

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 2

TABLE OF CONTENTS 1.

EXECUTIVE

SUMMARY

............................................................................................................................5 2.

SURVEY UNIT DESCRIPTION...................................................................................................................5 3.

CLASSIFICATION BASIS...........................................................................................................................5 4.

DATA QUALITY OBJECTIVES..................................................................................................................6 5.

SURVEY DESIGN.........................................................................................................................................9 6.

SURVEY IMPLEMENTATION.................................................................................................................13 7.

SURVEY RESULTS....................................................................................................................................14 8.

QUALITY CONTROL................................................................................................................................15 9.

INVESTIGATIONS AND RESULTS..........................................................................................................16 10.

REMEDIATION AND RESULTS...............................................................................................................16 11.

CHANGES FROM THE FINAL STATUS SURVEY PLAN......................................................................16 12.

DATA QUALITY ASSESSMENT...............................................................................................................16 13.

ANOMALIES...............................................................................................................................................17 14.

CONCLUSION............................................................................................................................................17 15.

REFERENCES............................................................................................................................................17 16.

ATTACHMENTS........................................................................................................................................18 ATTACHMENT 1 - FIGURES AND MAPS.........................................................................................................19 ATTACHMENT 2 - MEASUREMENT DATA......................................................................................................22 ATTACHMENT 3 - SIGN TEST.........................................................................................................................46 ATTACHMENT 4 - QUALITY CONTROL ASSESSMENT...................................................................................62 ATTACHMENT 5 - GRAPHICAL PRESENTATIONS.........................................................................................64

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 3

LIST OF TABLES Table 4 Dose Significant Radionuclides and Mixture for Buried Pipe.............................................................7 Table 4 Base Case DCGLs for Buried Pipe - Circulating Water Discharge Pipe...........................................8 Table 4 Operational DCGLs for Buried Pipe - Circulating Water Discharge Pipe........................................9 Table 5 Soil Surrogate Ratio............................................................................................................................9 Table 5 Investigation Levels...........................................................................................................................12 Table 5 Synopsis of Survey Design.................................................................................................................12 Table 7 Summary of Systematic, Judgmental, and QC Measurements.........................................................15 Table 7 Basic Statistical Properties of the Systematic Measurement Population..........................................15 Table 16 Survey Unit S1-011-102 Static Measurements Data Assessment....................................................23 Table 16 Survey Unit S1-011-102 Sign Test...................................................................................................47 Table 16 Survey Unit S1-011-102 QC Assessment.........................................................................................63 LIST OF FIGURES Figure 16 Survey Unit S1-011-102 Drawing...................................................................................................20 Figure 16 Survey Unit S1-011-102 Measurement Position Designations.......................................................21 Figure 16 Quantile Plot for Gross Gamma Activity......................................................................................65 Figure 16 Histogram for Gross Gamma Activity...........................................................................................66 Figure 16 Retrospective Power Curve for Survey Unit S1-011-102...............................................................67

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 4

LIST OF ACRONYMS AND ABBREVIATIONS ALARA As Low As Reasonably Achievable CWD Circulating Water Discharge DQO Data Quality Objective DCGL Derived Concentration Guideline Level DCGLBP Buried Pipe Base Case Derived Concentration Guideline Level FSS Final Status Survey HSA Historical Site Assessment IC Insignificant Contributors ID Internal Diameter LACBWR La Crosse Boiling Water Reactor LTP License Termination Plan MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual MCNP Monte Carlo Neutral Particle MDC Minimum Detectable Concentration NaI Sodium Iodide OpDCGLBP Buried Pipe Operational Derived Concentration Guideline Level QAPP Quality Assurance Project Plan QC Quality Control ROC Radionuclides of Concern SOF Sum of Fractions TEDE Total Effective Dose Equivalent TSD Technical Support Document UCL Upper Confidence Limit

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 5

1.

EXECUTIVE

SUMMARY

This Final Status Survey (FSS) Release Record for survey unit S1-011-102, Circulating Water Discharge (CWD) Pipe, has been generated in accordance with LaCrosseSolutions procedure LC-FS-PR-009, Final Status Survey Data Reporting (Reference 1) and satisfies the requirements of Section 5.11 of the La Crosse Boiling Water Reactor License Termination Plan (LACBWR LTP) (Reference 2).

An FSS sample plan for this survey unit was developed in accordance with LaCrosseSolutions procedures LC-FS-PR-002, Final Status Survey Package Development (Reference 3) and LC-FS-PR-018, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors (Reference 4), the LACBWR LTP, and with guidance from NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (Reference 5).

Survey unit S1-011-102 has a MARSSIM classification of 1. A survey plan was designed based upon use of the Sign Test as the nonparametric statistical test for compliance. Both the Type I ( ) and Type II ( ) decision error rates were set at 0.05. As a systematic measurement population, five hundred and ten (510) static gamma measurements were acquired from the survey unit. The data assessment results for survey unit S1-011-102 indicate that the maximum Sum of Fractions (SOF), considering the concentration of all applicable Radionuclides of Concern (ROC) either by direct measurement or by inference, is equal to 0.1131 when applying the respective Operational Derived Concentration Guideline Levels (OpDCGLBP) for buried pipe. The mean SOF when applying the respective Base Case DCGLs (DCGLBP) is 0.0012. This SOF equates to a dose for the survey unit of 0.0299 mrem/yr.

2.

SURVEY UNIT DESCRIPTION S1-011-102 is an impacted Class 1 buried pipe survey unit. The survey unit consists of the interior surface of the CWD Pipe. The steel pipe has an internal diameter (ID) of 60 inches and a total length of 421 feet. The pipe runs from the Turbine Building to a combined discharge structure on the banks of the Mississippi River. The interior surface area of the CWD Pipe is 614.37 m2 (6,143,736.42 cm2). Refer to Attachment 1 of this report for figures and maps depicting survey unit S1-011-102.

3.

CLASSIFICATION BASIS Based on the La Crosse Boiling Water Reactor Historical Site Assessment (HSA)

(Reference 6), the CWD Pipe was identified as a Class 1 system.

~

LACROSSESOLUTIONS a

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 6

Based upon review of the historical information and completion of a final Survey Unit Classification Worksheet from LC-FS-PR-006, Survey Unit Classification (Reference 7),

the correct final classification of survey unit S1-011-102 was determined to be Class 1.

4.

DATA QUALITY OBJECTIVES FSS planning and design relies on a properly executed Data Quality Objective (DQO) process to ensure, through compliance with explicitly defined inputs and boundaries, that the primary objective of the survey is satisfied. The DQO process is described in the LACBWR LTP in accordance with MARSSIM. The appropriate design for a given survey was developed using the DQO process as outlined in Appendix D of MARSSIM.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit would satisfy the primary objective of the FSS sample plan.

The primary objective of the FSS sample plan is to demonstrate that the level of residual radioactivity in survey unit S1-011-102 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

EnergySolutions Technical Support Document (TSD) RS-TD-313196-001, Radionuclides of Concern during LACBWR Decommissioning (Reference 8) established the basis for an initial suite of potential ROC for decommissioning. Insignificant contributors (IC) were determined consistent with the guidance contained in Section 3.3 of NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance - Characterization, Survey, and Determination of Radiological Criteria, Final Report (Reference 9). In all soil and concrete scenarios, Cs-137, Co-60, Sr-90, Eu-152 and Eu-154 contribute nearly 100% of the total dose. The remaining radionuclides were designated as IC and are eliminated from further detailed evaluation. Therefore, the final ROCs for LACBWR soil, basement concrete, and buried piping are Cs-137, Co-60, Sr-90, Eu-152 and Eu-154.

LTP, Section 6.14.1 discusses the process used to derive the ROC for the decommissioning of LACBWR, including the elimination of IC from the initial suite. Table 4-1 presents the

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 7

ROC for the decommissioning of buried pipe at LACBWR and the normalized mixture fractions based on the radionuclide mixture.

Table 4 Dose Significant Radionuclides and Mixture for Buried Pipe Radionuclide Fraction of Total Activity (normalized)(1)

Co-60 0.064 Sr-90 0.098 Cs-137 0.829 Eu-152 0.005 Eu-154 0.003 (1) Based on maximum percent of total activity from Table 22 of RS-TD-313196-001, normalized to one for the dose significant radionuclides.

The LTP, Section 5.2, states that each radionuclide-specific Base Case DCGL is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem/yr to an Average Member of the Critical Group. To ensure that the summation of dose from each source term is 25 mrem/yr or less after all FSS is completed, the Base Case DCGLs are reduced based on an expected, or a priori, fraction of the 25 mrem/yr dose limit from each source term. The reduced DCGLs, or Operational DCGLs, can be related to the Base Case DCGLs as an expected fraction of dose based on an a priori assessment of what the expected dose should be based on the results of site characterization, process knowledge, and the extent of planned remediation. The Operational DCGL is then used as the DCGL for the FSS design of the survey unit (i.e., calculation of surrogate DCGLs and investigations levels). Details of the Operational DCGLs derived for each dose component and the basis for the applied a priori dose fractions are provided in LC-FS-TSD-002, Operational Derived Concentration Guideline Levels for Final Status Survey (Reference 10).

The dose contribution from each ROC is accounted for using the SOF to ensure that the total dose from all ROC does not exceed the dose criterion. A Base Case DCGL that is established for the average residual radioactivity in a survey unit is equivalent to a DCGLW.

The DCGLW can be multiplied by Area Factors to obtain a Base Case DCGL that represents the same dose to an individual for residual radioactivity over a smaller area within a survey unit.

At LACBWR, compliance is demonstrated through the summation of dose from five (5) distinct source terms for the end state (basements, soils, buried pipe, above-ground structures, and groundwater). When applied to buried pipe, the DCGLs are expressed in units of activity per surface area (dpm/100 cm2).

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 8

Buried piping is defined as below ground pipe located outside of structures and basements.

The dose assessment methods and resulting DCGLs for buried piping are described in detail in LTP, Section 6.20. The buried piping was separated into two categories. The first category included the summation and grouping of all impacted buried pipe other than the CWD Pipe and is designated as the Buried Pipe Group. The second category consisted of the CWD Pipe only. The separation of the Circulating Water pipe was necessary because the geometry of the CWD pipe was significantly different than the other pipes, and the pipes are located in distinctly different parts of the site.

EnergySolutions TSD RS-TD-313196-004, LACBWR Soil DCGL, Basement Concrete DCGL, and Buried Pipe DCGL (Reference 11) and LTP, Section 6.20, provide the exposure scenarios and modeling parameters that were used to calculate the site-specific buried pipe DCGLs. The final DCGLs to be used during FSS account for the fact that the dose from the In Situ and Excavation scenarios must be summed in the conceptual model for buried pipe dose assessment (i.e., the In Situ and Excavation scenarios occur in parallel). The summed Buried Pipe Base Case DCGLs are reproduced in Table 4-2 below. The IC dose percentages for each of the buried pipe scenarios were used to adjust each buried pipe Base Case DCGL to account for the dose from the eliminated IC radionuclides. The Operational DCGLs for the CWD Pipe are provided in Table 4-3.

Table 4 Base Case DCGLs for Buried Pipe - Circulating Water Discharge Pipe Radionuclide DCGLBP (dpm/100 cm2)

Co-60 7.75E+04 Sr-90 7.55E+05 Cs-137 3.30E+05 Eu-152 1.67E+05 Eu-154 1.56E+05

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 9

Table 4 Operational DCGLs for Buried Pipe - Circulating Water Discharge Pipe Radionuclide OpDCGLBP (dpm/100 cm2)

Co-60 1.63E+04 Sr-90 1.58E+05 Cs-137 6.94E+04 Eu-152 3.51E+04 Eu-154 3.27E+04 Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the Operational DCGL. Survey instrument response checks were required prior to issuance and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

In accordance with the LTP, the minimum acceptable MDC for measurements obtained using field instruments was 50% of the applicable Operational DCGL.

5.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey unit and nature of the hazards. Guidance for preparing FSS plans is provided in procedure LC-FS-PR-002, Final Status Survey Package Development.

The DQO process validated that Co-60, Sr-90, Cs-137, Eu-152, and Eu-154 would be the ROC in survey unit S1-011-102 as presented in LTP, Section 5.1. During the data analysis of the FSS results, concentrations for the HTD ROC Sr-90 are inferred using a surrogate approach. Cs-137 is the principle surrogate radionuclide for Sr-90. During characterization, both Sr-90 and Cs-137 was positively detected in all thirty (30) concrete core samples assessed in the Reactor Building, Tunnel, and Waste Treatment Building. The 95% Upper Confidence Limit (UCL) of the Cs-137 fractions was chosen to represent the overall nuclide mix for soils/buried pipe, the Reactor Building, and the Waste Gas Tank Vault. The surrogate ratio for soil/buried pipe is given in Table 5-1.

Table 5 Soil Surrogate Ratio Radionuclides Ratio Sr-90/Cs-137 0.502 The equation for calculating a surrogate DCGL is as follows:

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 10 Equation 1

=

1 1

+

+

+

Where:

DCGLSur

=

Surrogate radionuclide DCGL DCGL2,3n

=

DCGL for radionuclides to be represented by the surrogate Rn

=

Ratio of concentration (or nuclide mixture fraction) of radionuclide n to surrogate radionuclide Using the Operational DCGLs presented in Table 4-3 and the ratio from Table 5-1, the following surrogate calculation was performed:

Equation 2

(

) =

1 1

6.94

+ 04(

) +

0.502 1.58

+ 05(

)

= 5.69

+ 04

/100 The surrogate Operational DCGL for Cs-137 is then used in the calculation of the gross gamma Operational DCGL, as calculated in Equation 3.

Equation 3

(

)

=

1 0.071 1.63

+ 04(

) +

0.919 5.69

+ 04

+

0.006 3.51

+ 04(

) +

0.003 3.27

+ 04(

)

= 4.81

+ 04

/100 The action level for survey unit S1-011-102 was equivalent to the calculated gross gamma Operational DCGL of 4.81E+04 dpm/100 cm2.

For the survey of interior pipe surfaces, areal coverage is achieved by the area of detection for each static measurement collected. Scanning, in the traditional context, is not applicable to the survey of pipe internal surfaces. For the survey of the CWD Pipe, the detector was erroneously calibrated for a specific geometry of a 3,050 cm2 (1 ft x 1 m) area of contamination on the bottom of the pipe, resulting in inaccurate detector efficiencies and inaccurate calculations for activity per area. TSD LC-FS-TSD-005, MCNP Modeling of Water Discharge Pipes for the LaCrosse Boiling Water Reactor (Reference 12) was written

~

LACROSSESOLUTIONS SurrogatevccL SurrogatevccL cs-137

[ (-E-cs--137) (

E Sr-90 ) ]

E dpm cm2 SurrogatevcGL gamma

[(

E Co-60 )

(

E Cs-137)

(

E Eu-152 )

(

E Eu-154 ) ]

E dpm cm2

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 11 to address the discrepancy in efficiency and area of detection. The TSD details the Monte Carlo Neutral Particle (MCNP) radiation transport code that modeled the response of a NaI detector to a calibration source for several different pipe sizes. The MCNP models resulted in efficiency correction factors. The calculated efficiency from original source calibration can be multiplied by the correction factors to obtain an efficiency that more realistically portrays the specific contamination geometry of the pipe. For a 60 ID pipe, each measurement has a true Field-of-View (FOV) of 14,590 cm2.

The CWD Pipe contains 421 linear feet of 60 ID steel piping, which equates to a surface area of 614.37 m2 (6,143,736.42 cm2). The LTP states that a Class 1 FSS survey unit shall have an areal coverage of 100%. Therefore, one (1) measurement was to be collected every one (1) linear foot traversed through the pipe, for a total of at least four hundred and twenty-one (421) distinct measurements over the entire accessible pathway of the piping system.

During survey design, eighty-nine (89) systematic static measurements (approximately four

[4] every twenty [20] feet) were added in an effort to assess the sides and top of the pipe (see Figure 16-2), for a total of five hundred and ten (510) static measurements that make up the systematic measurement population.

Each static measurement represents the gamma activity in gross counts per minute (cpm) for each specific measurement location. Background is subtracted, then the value is converted to dpm using an efficiency factor based on the calibration source and the efficiency correction factors detailed in TSD LC-FS-TSD-005, MCNP Modeling of Water Discharge Pipes for the LaCrosse Boiling Water Reactor. The total activity in dpm is then adjusted for the assumed effective surface area commensurate with the pipe diameter, resulting in units of dpm/100 cm2. The total gamma surface activity for each measurement was converted to an activity concentration for each gamma-emitting ROC, based on the normalized gamma mixture from Table 4-1. Concentrations for the HTD ROC Sr-90 were inferred using the surrogate approach in accordance with LTP Chapter 5.

The implementation of quality control measures as referenced by LTP, Section 5.9 and LaCrosseSolutions LC-QA-PN-001, Final Status Survey Quality Assurance Project Plan (QAPP) (Reference 13) includes the collection of replicate static measurements on 5% of the systematic measurements collected in the survey unit, with the locations selected at random. Twenty-five (25) replicate static measurements were selected for Quality Control (QC) analysis for the FSS of this survey unit.

For this Class 1 buried pipe survey unit, the Investigation Levels for measurement results are those levels specified in LTP Chapter 5, Table 5-16, and are reproduced below in Table 5-2.

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 12 Table 5 Investigation Levels Classification Scan Investigation Levels Direct Investigation Levels Class 1

>Operational DCGL or >MDCscan if MDCscan is greater than Operational DCGL

>Operational DCGL Table 5-3 provides a synopsis of the survey design for survey unit S1-011-102.

Table 5 Synopsis of Survey Design Feature Design Criteria Basis Survey Unit Surface Area 614.37 m2 (6,143,736.42 cm2) 421 421 of 60 diameter steel pipe Number of Systematic Measurements (N) 510 100% coverage Operational DCGLs (dpm/100 cm2)

Co-60: 1.63E+04 Sr-90: 1.58E+05 Cs-137: 6.94E+04 Eu-152: 3.51E+04 Eu-154: 3.27E+04 Operational DCGLs for buried pipe, LTP, Table 5-8, Release Record, Table 4-3 Action Level 4.81E+04 dpm/100 cm2 Gross Gamma Operational DCGL, Equation 3 Investigation Level

>Operational DCGL LTP, Table 5-16 Scan Areal Coverage N/A LTP, Section 5.7.1.8 Number of Judgmental Measurements 1

2 Per Sample Plan Actual Number Obtained QC 25 replicate measurements LTP, Section 5.9 Non-parametric Statistical Test Sign Test LTP, Section 5.6.4.2

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 13 6.

SURVEY IMPLEMENTATION FSS field activities were conducted under the FSS sample plan, which included DQOs, survey design, detailed FSS instructions, job safety analysis, and related procedures for reference. The survey unit was inspected and controlled in accordance with LC-FS-PR-010, Isolation and Control for Final Status Survey (Reference 14). A Field Log was used to document field activities and other information pertaining to the performance of the FSS.

FSS field activities commenced on April 22, 2018.

FSS field activities were projected to take four (4) working days to complete. Daily briefings were conducted to discuss the expectations for job performance and to review safety aspects of the job. The survey-required field activities were performed during normal working hours and concluded on April 25, 2018.

Background measurements were acquired in the North Yard area of the site. These readings were found to be inconsistent with the activity measured in the pipe; nearly all measurements were negative after subtracting background. It was determined that the backgrounds originally collected for the CWD pipe were not representative of true background levels. Because the CWD pipe was no longer accessible after survey implementation, a background value was developed from the existing survey data. TSD LC-FS-TSD-003, Assessment of the LACBWR Circulating Water Discharge Pipe Final Status Survey Data for Detection Efficiency and Detector Background (Reference 15) details the process and justification for using a mean value of the data as a reasonable background value.

Daily, prior to and following use, each detector was subjected to an Operational Response Check in accordance with procedure LC-FS-PR-018, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors. The Daily Operational Response Check compared the background response and the response to check source ranges established for normal background and detector source response to ensure that the detector was working properly.

The five hundred and ten (510) systematic 1-minute static measurements were collected using a Ludlum Model 2350-1 paired with a Model 44-10 NaI detector operated in the rate-meter mode and using audio response. The detector was fitted into a wheeled rig, which maintained a fixed detector geometry, an area of detection of 14,590 cm2. The static MDC was sufficient to detect residual radioactivity at the action level (adjusted gross gamma Operational DCGL of 4.81E+04 dpm/100 cm2). Complete measurement results are provided in Attachment 2.

Two (2) judgmental static measurements were collected during implementation of FSS.

The implementation of survey specific QC measures included the collection of twenty-five (25) replicate static measurements for QC analysis.

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 14 7.

SURVEY RESULTS The SOF or unity rule is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determined to be potentially present. The equation for the unity rule is:

Equation 4 Where:

Cn

=

concentration of radionuclide n DCGLn

=

DCGL of radionuclide n.

The application of the unity rule serves to normalize the data to allow for an accurate comparison of the various data measurements to the release criteria. When the unity rule is applied, the DCGLW (used for the nonparametric statistical test) becomes one (1). The DCGLBP are directly analogous to the DCGLW as defined in MARSSIM. The use and application of the unity rule was performed in accordance with section 4.3.3 of MARSSIM.

As described in LTP, Section 5.10.3.2, the Sign Test was used to evaluate the measured residual radioactivity against the dose criterion. The SOF for each measurement was used as the sum value for the Sign Test. The Sign Test then demonstrated that the mean activity for each ROC was less than the OpDCGLBP at a Type I decision error of 0.05. The results of the Sign Test are presented in Attachment 3.

For buried pipe, areas of elevated activity were defined as any area identified by measurement (systematic or judgmental) that exceeded the OpDCGLBP but was less than the DCGLBP. The SOF (based on the OpDCGLB) for a systematic or judgmental measurement can exceed one (1) without remediation as long as the survey unit passes the Sign Test, and the mean SOF (based on the OpDCGLBP) for the survey unit does not exceed one (1). Once the survey data set passes the Sign Test (using Operational DCGLs), then the mean radionuclide activity for each ROC from systematic measurements along with any identified elevated areas from systematic and judgmental samples can be used with the Base Case DCGLs to perform a mean SOFBP calculation. The dose from residual radioactivity assigned to the FSS unit is the mean SOFBP multiplied by 25 mrem/yr.

The systematic measurement population consisted of five hundred and ten (510) static measurements that were acquired using the Ludlum Model 2350-1 paired to a Model 44-10 detector. In total, five hundred and thirty-seven (537) static measurements were collected, including the systematic, judgmental, and QC measurements. A breakdown of the total static measurements and SOF for systematic measurements compared to the OpDCGLBP is provided in Table 7-1. A summary of the results of the systematic measurements taken for 1

2 2

1 1

DCGL C

DCGL C

DCGL C

n n

~

LACROSSESOLUTIONS

--+--+

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 15 non-parametric statistical testing when compared to the DCGLBP is provided in Table 7-2.

The complete results of the data assessment for survey unit S1-011-102 are provided in.

Table 7 Summary of Systematic, Judgmental, and QC Measurements Total Number of Systematic Measurements 510 Number of Quality Control Measurements 25 Number of Judgmental Measurements 2

Total Number of Measurements 537 Mean Systematic Measurement SOF (1) 0.0057 Max Individual Systematic Measurement SOF (1) 0.1131 Number of Systematic Measurements with SOF > 1 (1) 0 Number of Judgmental Measurements with SOF > 1 (1) 0 (1) Based on the OpDCGLBP Table 7 Basic Statistical Properties of the Systematic Measurement Population ROC Mean Median Max.

Min.

St. Dev.

(dpm/100 cm2)

BcDCGL Avg. SOF per ROC Avg. Dose per ROC (dpm/100 cm2)

(dpm/100 cm2)

(dpm/100 cm2)

(dpm/100 cm2)

(dpm/100 cm2)

Co-60 1.95E+01 0.00E+00 3.88E+02 0.00E+00 5.26E+01 7.75E+04 0.0003 0.0063 Cs-137 2.51E+02 0.00E+00 5.00E+03 0.00E+00 6.77E+02 3.30E+05 0.0008 0.0190 Eu-152 1.67E+00 0.00E+00 3.31E+01 0.00E+00 4.49E+00 1.67E+05 0.0000 0.0002 Eu-154 8.52E-01 0.00E+00 1.69E+01 0.00E+00 2.30E+00 1.56E+05 0.0000 0.0001 Sr-90 1.26E+02 0.00E+00 2.51E+03 0.00E+00 3.40E+02 7.55E+05 0.0002 0.0042 SUM 0.0012 0.0299 The mean SOF for the CWD Pipe, based on the mean concentration for each ROC as measured by the systematic measurement population when compared against the DCGLBP, is 0.0012. This SOF equates to a dose of 0.0299 mrem/yr.

8.

QUALITY CONTROL The implementation of survey specific QC measures included the collection of twenty-five (25) replicate static measurements for QC analysis. The acceptance criteria for replicate static measurements is that the same conclusion is reached for each measurement. This is defined as the replicate measurement being within 20% of the standard measurement. In cases where the replicate measurement is not within 20% of the standard measurement, but both measurements are below the Operational DCGL, there is an acceptable agreement.

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 16 Fourteen (14) QC replicate measurement did not fall within the 20% criteria, but both the standard and replicate measurements were well below the Operational DCGL. No further action was deemed necessary, and there is an acceptable agreement between standard and replicate results. Refer to Attachment 4 for QC analysis results.

9.

INVESTIGATIONS AND RESULTS No investigations were performed during the performance or analyses of the survey.

10.

REMEDIATION AND RESULTS No radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit. Chapter 4 of the LTP determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in buried pipe was ALARA.

11.

CHANGES FROM THE FINAL STATUS SURVEY PLAN TSDs LC-FS-TSD-003, Assessment of the LACBWR Circulating Water Discharge Pipe Final Status Survey Data for Detection Efficiency and Detector Background, and LC-FS-TSD-005, MCNP Modeling of Water Discharge Pipes for the LaCrosse Boiling Water Reactor, were developed in response to inaccurate efficiency calibration geometries and backgrounds originally assumed in the sample plan and during survey implementation.

12.

DATA QUALITY ASSESSMENT The DQO survey design and data were reviewed in accordance with LC-FS-PR-008, Final Status Survey Data Assessment (Reference 16) for completeness and consistency.

Documentation was complete and legible. Surveys were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 1. The survey design had adequate power as indicated by the Retrospective Power Curve (see Attachment 5).

All measurements were less than a SOF of one (1) when compared to the OpDCGLBP.

The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results clearly demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). All data was considered valid including negative values, zeros, values reported below the MDC, and values with uncertainties that exceeded two standard deviations. The mean and median values for each ROC were well below the respective

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 17 Operational DCGLs. Also, the retrospective power curve shows that a sufficient number of measurements were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.

13.

ANOMALIES No anomalies were observed during the performance or analyses of the survey.

14.

CONCLUSION Survey unit S1-011-102 has met the DQOs of the FSS plan. The ALARA criteria as specified in Chapter 4 of the LTP were achieved.

The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve showed that adequate power was achieved. The survey unit is properly classified as Class 1. Therefore, in accordance with LTP Section 5.11, the survey unit meets the release criteria.

The dose contribution from survey unit S1-011-102 is 0.0299 mrem/yr TEDE, based on the average concentration of the ROC in measurements used for non-parametric statistical testing (mean SOF).

Survey unit S1-011-102 is acceptable for unrestricted release.

15.

REFERENCES

1. LC-FS-PR-009, Final Status Survey Data Reporting
2. La Crosse Boiling Water Reactor License Termination Plan
3. LC-FS-PR-002, Final Status Survey Package Development
4. LC-FS-PR-018, Radiation Surveys of Pipe Interiors Using Sodium/Cesium Iodide Detectors
5. NUREG-1575, Revision 1, Multi-Agency Radiation Survey and Site Investigation Manual
6. La Crosse Boiling Water Reactor Historical Site Assessment
7. LC-FS-PR-006, Survey Unit Classification
8. RS-TD-313196-001, Radionuclides of Concern during LACBWR Decommissioning
9. NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance -

Characterization, Survey, and Determination of Radiological Criteria, Final Report

10. LC-FS-TSD-002, Operational Derived Concentration Guideline Levels for Final Status Survey DCGL
11. RS-TD-313196-004, LACBWR Soil DCGL, Basement Concrete DCGL, and Buried Pipe

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 18

12. LC-FS-TSD-005, MCNP Modeling of Water Discharge Pipes for the LaCrosse Boiling Water Reactor
13. LC-QA-PN-001, Final Status Survey Quality Assurance Project Plan
14. LC-FS-PR-010, Isolation and Control for Final Status Survey
15. LC-FS-TSD-003, Assessment of the LACBWR Circulating Water Discharge Pipe Final Status Survey Data for Detection Efficiency and Detector Background
16. LC-FS-PR-008, Final Status Survey Data Assessment 16.

ATTACHMENTS - Figures and Maps - Measurement Data - Sign Test - Quality Control Assessment - Graphical Presentations

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 19 ATTACHMENT 1 FIGURES AND MAPS

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 20 Figure 16 Survey Unit S1-011-102 Drawing T HRIJST E:!LOC:

lYflc" *e,* -

~

LACROSSESOLUTIONS 3._j* SiJE;;..!&'~-v~,c;_JE:-LJb~L205;!';;.::..*" s:s:-c-:~I ~~~~:;::~==~==;;;;;;;;;;;;;;;;;;~i=-=:-.~

~,~ P THR~~T ~LO(;I(

TY:P1E: *A*

l;'<l~T (1.0"1" OtS.C.tt CIRC. w.,q Ft TH 6i ~LO'(;

rne *c*

IJ~I',' ~ *d JUCIAC, PlPt H~U'!>T e.~oc l'fl' ~. I>'

_ (<W i..01~ SUh c,,..,c "'~Tic"', D*~C.~.

~JI.OM ~UC. li,,6,,t PLANT

~

~~r.rei,r;;!~"J'o.. DF...,, P,Pf; I

1'\\ **.)

\\*,\\

~~w l t..lfAK~ !llllUCf,

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 21 Figure 16 Survey Unit S1-011-102 Measurement Position Designations

~

LACROSSESOLUTIONS Pos r r n H

Position r*

Po.sl Ion "G

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 22 ATTACHMENT 2 MEASUREMENT DATA

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102

~

LACROSSESOLUTIONS Table 16-1-Survey Unit S1-011-102 Static Measurements Data Assessment Measurement Gamma Result Activity' (dpm/100 cm2)

Fraction ofOpDCGL Measurement Population Measurement ID OpSOF dpm/100 cm2 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 s

GOI 603 4.30E+Ol 5.54E+02 3.67E+OO l.88E+OO 2.78E+02 0.0026 0.0080 0.0001 0.0001 0.0018 0.0125 s

HOI 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

IOI 11 7.73E-Ol 9.95E+OO 6.59E-02 3.37E-02 5.00E+OO 0.0000 0.0001 0.0000 0.0000 0.0000 0.0002 s

JOI 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

G02 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

H02 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

I02 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

J02 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

G03 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

H03 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

I03 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

103 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

G04 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

H04 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

I04 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

104 0

O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 s

GOS 453 3.23E+Ol 4.16E+02 2.76E+OO 1.41E+OO 2.09E+02 0.0020 0.0060 0.0001 0.0000 0.0013 0.0094 s

HOS 193 l.38E+Ol l.77E+02 l.18E+OO 6.02E-Ol 8.91E+Ol 0.0008 0.0026 0.0000 0.0000 0.0006 0.0040 s

I05 319 2.28E+Ol 2.94E+02 l.94E+OO 9.95E-Ol l.47E+02 0.0014 0.0042 0.0001 0.0000 0.0009 0.0066 s

105 691 4.94E+Ol 6.35E+02 4.21E+OO 2.15E+OO 3.19E+02 0.0030 0.0092 0.0001 0.0001 0.0020 0.0144 s

G06 171 l.22E+Ol l.58E+02 l.04E+OO 5.34E-Ol 7.91E+Ol 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 s

H06 211 l.51E+Ol l.94E+02 l.29E+OO 6.58E-Ol 9.74E+Ol 0.0009 0.0028 0.0000 0.0000 0.0006 0.0044 s

I06 150 l.07E+Ol l.38E+02 9.12E-Ol 4.67E-Ol 6.91E+Ol 0.0007 0.0020 0.0000 0.0000 0.0004 0.0031 23

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

106 69 4.90E+OO s

G07 0

O.OOE+OO s

H07 0

O.OOE+OO s

I07 0

O.OOE+OO s

107 0

O.OOE+OO s

GOS 0

O.OOE+OO s

HOS 0

O.OOE+OO s

I08 43 3.09E+OO s

108 0

O.OOE+OO s

G09 0

O.OOE+OO s

H09 0

O.OOE+OO s

I09 0

O.OOE+OO s

109 0

O.OOE+OO s

GlO 0

O.OOE+OO s

HlO 0

O.OOE+OO s

IlO 0

O.OOE+OO s

no 0

O.OOE+OO s

Gll 0

O.OOE+OO s

Hll 0

O.OOE+OO s

Ill 0

O.OOE+OO s

Jl l 0

O.OOE+OO s

Gl2 0

O.OOE+OO s

Hl2 0

O.OOE+OO s

Il2 0

O.OOE+OO Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 6.30E+Ol 4.l7E-Ol 2.14E-Ol O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.98E+Ol 2.64E-Ol l.35E-Ol O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 24

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 3.16E+Ol 0.0003 0.0009 0.0000 0.0000 0.0002 0.0014 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.00E+Ol 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

Jl2 0

0.00E+00 s

Gl3 184 l.31E+0l s

Hl3 0

0.00E+00 s

113 60 4.25E+00 s

Jl3 0

0.00E+00 s

Gl4 0

0.00E+00 s

Hl4 18 l.29E+00 s

Il4 7

5.l5E-0l s

Jl4 74 5.28E+00 s

Gl5 144 l.03E+0l s

HIS 0

0.00E+00 s

Il5 14 l.03E+00 s

Jl5 0

0.00E+00 s

Gl6 420 3.00E+0l s

Hl6 67 4.77E+00 s

Il6 218 l.56E+0l s

Jl6 175 l.25E+0l s

Gl7 671 4.79E+0l s

Hl7 709 5.06E+0l s

Il7 880 6.29E+0l s

Jl7 651 4.65E+0l s

Gl8 514 3.67E+0l s

HIS 563 4.02E+0l s

Il8 485 3.47E+0l Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 l.69E+02 l.12E+00 5.73E-0l 0.00E+00 0.00E+00 0.00E+00 5.47E+0l 3.62E-0l l.86E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.66E+0l l.l0E-01 5.62E-02 6.63E+00 4.39E-02 2.25E-02 6.80E+0l 4.S0E-01 2.31E-0l l.33E+02 8.79E-0l 4.S0E-01 0.00E+00 0.00E+00 0.00E+00 l.33E+0l 8.79E-02 4.S0E-02 0.00E+00 0.00E+00 0.00E+00 3.86E+02 2.56E+00 l.31E+00 6.l4E+0l 4.06E-0l 2.08E-0l 2.0IE+02 l.33E+00 6.80E-0l l.61E+02 l.07E+00 5.45E-0l 6.l7E+02 4.09E+00 2.09E+00 6.52E+02 4.32E+00 2.21E+00 8.09E+02 5.36E+00 2.74E+00 5.99E+02 3.97E+00 2.03E+00 4.73E+02 3.13E+00 l.60E+00 5.l8E+02 3.43E+00 l.75E+00 4.46E+02 2.95E+00 l.51E+00 25

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 8.49E+0l 0.0008 0.0024 0.0000 0.0000 0.0005 0.0038 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.75E+0l 0.0003 0.0008 0.0000 0.0000 0.0002 0.0012 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 8.33E+00 0.0001 0.0002 0.0000 0.0000 0.0001 0.0004 3.33E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0002 3.41E+0l 0.0003 0.0010 0.0000 0.0000 0.0002 0.0015 6.66E+0l 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 6.66E+00 0.0001 0.0002 0.0000 0.0000 0.0000 0.0003 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 l.94E+02 0.0018 0.0056 0.0001 0.0000 0.0012 0.0088 3.08E+0l 0.0003 0.0009 0.0000 0.0000 0.0002 0.0014 l.01E+02 0.0010 0.0029 0.0000 0.0000 0.0006 0.0045 8.08E+0l 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 3.l0E+02 0.0029 0.0089 0.0001 0.0001 0.0020 0.0140 3.27E+02 0.0031 0.0094 0.0001 0.0001 0.0021 0.0148 4.06E+02 0.0039 0.0117 0.0002 0.0001 0.0026 0.0183 3.0IE+02 0.0029 0.0086 0.0001 0.0001 0.0019 0.0136 2.37E+02 0.0023 0.0068 0.0001 0.0000 0.0015 0.0107 2.60E+02 0.0025 0.0075 0.0001 0.0001 0.0016 0.0117 2.24E+02 0.0021 0.0064 0.0001 0.0000 0.0014 0.0101

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

Jl8 548 3.92E+0l s

Gl9 440 3.l4E+0l s

Hl9 229 l.64E+0l s

119 318 2.27E+0l s

Jl9 213 l.52E+0l s

G20 124 8.89E+00 s

H20 217 l.55E+0l s

120 128 9.l5E+00 s

J20 303 2.l6E+0l s

G2l 41 2.96E+00 s

H2l 0

0.00E+00 s

121 0

0.00E+00 s

J2l 0

0.00E+00 s

G22 4058 2.90E+02 s

H22 5434 3.88E+02 s

122 5346 3.82E+02 s

J22 4592 3.28E+02 s

A00 949 6.78E+0l s

A0l 395 2.82E+0l s

A02 0

0.00E+00 s

A03 0

0.00E+00 s

A04 0

0.00E+00 s

A05 0

0.00E+00 s

A06 0

0.00E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 5.04E+02 3.34E+00 l.71E+00 4.05E+02 2.68E+00 l.37E+00 2.llE+02 l.40E+00 7.l4E-0l 2.92E+02 l.93E+00 9.90E-0l l.96E+02 l.30E+00 6.63E-0l l.l4E+02 7.58E-0l 3.88E-0l l.99E+02 l.32E+00 6.75E-0l l.l8E+02 7.80E-0l 3.99E-0l 2.79E+02 l.85E+00 9.45E-0l 3.82E+0l 2.53E-0l l.29E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.73E+03 2.47E+0l l.26E+0l 5.00E+03 3.3lE+0l l.69E+0l 4.91E+03 3.25E+0l l.67E+0l 4.22E+03 2.80E+0l l.43E+0l 8.72E+02 5.78E+00 2.96E+00 3.63E+02 2.4lE+00 l.23E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 26

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 2.53E+02 0.0024 0.0073 0.0001 0.0001 0.0016 0.0114 2.03E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0092 l.06E+02 0.0010 0.0030 0.0000 0.0000 0.0007 0.0048 l.47E+02 0.0014 0.0042 0.0001 0.0000 0.0009 0.0066 9.83E+0l 0.0009 0.0028 0.0000 0.0000 0.0006 0.0044 5.75E+0l 0.0005 0.0016 0.0000 0.0000 0.0004 0.0026 9.99E+0l 0.0009 0.0029 0.0000 0.0000 0.0006 0.0045 5.9lE+0l 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 l.40E+02 0.0013 0.0040 0.0001 0.0000 0.0009 0.0063 l.92E+0l 0.0002 0.0005 0.0000 0.0000 0.0001 0.0009 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 l.87E+03 0.0178 0.0538 0.0007 0.0004 0.0119 0.0845 2.51E+03 0.0238 0.0720 0.0009 0.0005 0.0159 0.1131 2.47E+03 0.0234 0.0708 0.0009 0.0005 0.0156 0.1113 2.l2E+03 0.0201 0.0608 0.0008 0.0004 0.0134 0.0956 4.38E+02 0.0042 0.0126 0.0002 0.0001 0.0028 0.0198 l.82E+02 0.0017 0.0052 0.0001 0.0000 0.0012 0.0082 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

A07 0

0.00E+00 s

A08 0

0.00E+00 s

A09 0

0.00E+00 s

AI0 0

0.00E+00 s

All 0

0.00E+00 s

Al2 0

0.00E+00 s

Al3 0

0.00E+00 s

Al4 0

0.00E+00 s

Al5 0

0.00E+00 s

Al6 0

0.00E+00 s

A17 0

0.00E+00 s

Al8 0

0.00E+00 s

Al9 0

0.00E+00 s

A20 0

0.00E+00 s

A21 0

0.00E+00 s

A22 0

0.00E+00 s

A23 0

0.00E+00 s

A24 0

0.00E+00 s

A25 0

0.00E+00 s

A26 0

0.00E+00 s

A27 0

0.00E+00 s

A28 0

0.00E+00 s

A29 0

0.00E+00 s

A30 0

0.00E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 27

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

A31 0

0.00E+00 s

A32 0

0.00E+00 s

A33 0

0.00E+00 s

A34 0

0.00E+00 s

A35 0

0.00E+00 s

A36 0

0.00E+00 s

A37 0

0.00E+00 s

A38 0

0.00E+00 s

A39 0

0.00E+00 s

A40 0

0.00E+00 s

A41 0

0.00E+00 s

A42 0

0.00E+00 s

A43 0

0.00E+00 s

A44 0

0.00E+00 s

A45 0

0.00E+00 s

A46 0

0.00E+00 s

A47 0

0.00E+00 s

A48 0

0.00E+00 s

A49 0

0.00E+00 s

AS0 0

0.00E+00 s

ASI 0

0.00E+00 s

A52 0

0.00E+00 s

A53 0

0.00E+00 s

A54 0

0.00E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 28

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

A55 0

0.00E+00 s

A56 0

0.00E+00 s

A57 0

0.00E+00 s

A58 0

0.00E+00 s

A59 0

0.00E+00 s

A60 0

0.00E+00 s

A61 0

0.00E+00 s

A62 0

0.00E+00 s

A63 0

0.00E+00 s

A64 0

0.00E+00 s

A65 70 5.03E+00 s

A66 159 l.l3E+0l s

A67 0

0.00E+00 s

A68 88 6.3lE+00 s

A69 0

0.00E+00 s

A70 0

0.00E+00 s

A7l 202 l.44E+0l s

A72 597 4.27E+0l s

A73 520 3.7lE+0l s

A74 462 3.30E+0l s

A75 586 4.19E+0l s

A76 339 2.42E+0l s

A77 411 2.94E+0l s

A78 527 3.76E+0l Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.47E+0l 4.28E-0l 2.19E-0l l.46E+02 9.67E-0l 4.95E-0l 0.00E+00 0.00E+00 0.00E+00 8.l3E+0l 5.38E-0l 2.75E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.86E+02 l.23E+00 6.30E-0l 5.49E+02 3.64E+00 l.86E+00 4.78E+02 3.16E+00 l.62E+00 4.25E+02 2.8lE+00 l.44E+00 5.39E+02 3.57E+00 l.83E+00 3.12E+02 2.07E+00 l.06E+00 3.78E+02 2.50E+00 l.28E+00 4.84E+02 3.2lE+00 l.64E+00 29

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.25E+0l 0.0003 0.0009 0.0000 0.0000 0.0002 0.0015 7.33E+0l 0.0007 0.0021 0.0000 0.0000 0.0005 0.0033 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.08E+0l 0.0004 0.0012 0.0000 0.0000 0.0003 0.0018 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 9.33E+0l 0.0009 0.0027 0.0000 0.0000 0.0006 0.0042 2.76E+02 0.0026 0.0079 0.0001 0.0001 0.0017 0.0124 2.40E+02 0.0023 0.0069 0.0001 0.0000 0.0015 0.0108 2.l3E+02 0.0020 0.0061 0.0001 0.0000 0.0013 0.0096 2.71E+02 0.0026 0.0078 0.0001 0.0001 0.0017 0.0122 l.57E+02 0.0015 0.0045 0.0001 0.0000 0.0010 0.0071 l.90E+02 0.0018 0.0054 0.0001 0.0000 0.0012 0.0086 2.43E+02 0.0023 0.0070 0.0001 0.0001 0.0015 0.0110

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

A79 384 2.74E+0l s

A80 328 2.35E+0l s

A8l 429 3.07E+0l s

A82 363 2.59E+0l s

A83 175 l.25E+0l s

A84 280 2.00E+0l s

A85 437 3.l2E+0l s

A86 384 2.74E+0l s

A87 251 l.79E+0l s

A88 538 3.84E+0l s

A89 431 3.08E+0l s

A90 355 2.54E+0l s

A9l 484 3.45E+0l s

A92 251 l.79E+0l s

A93 217 l.55E+0l s

A94 280 2.00E+0l s

A95 585 4.l7E+0l s

A96 399 2.85E+0l s

A97 186 l.33E+0l s

A98 301 2.l5E+0l s

A99 150 l.07E+0l s

801 155 l.l lE+0l s

802 364 2.60E+0l s

803 321 2.29E+0l Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 3.53E+02 2.34E+00 l.20E+00 3.02E+02 2.00E+00 l.02E+00 3.95E+02 2.6lE+00 l.34E+00 3.33E+02 2.2lE+00 l.l3E+00 l.61E+02 l.07E+00 5.45E-0l 2.57E+02 l.70E+00 8.71E-0l 4.0lE+02 2.66E+00 l.36E+00 3.53E+02 2.34E+00 l.20E+00 2.31E+02 l.53E+00 7.82E-0l 4.94E+02 3.27E+00 l.68E+00 3.96E+02 2.63E+00 l.34E+00 3.27E+02 2.l6E+00 l.l lE+00 4.45E+02 2.94E+00 l.SlE+00 2.31E+02 l.53E+00 7.82E-0l l.99E+02 l.32E+00 6.75E-0l 2.57E+02 l.70E+00 8.71E-0l 5.37E+02 3.56E+00 l.82E+00 3.67E+02 2.43E+00 l.24E+00 l.71E+02 l.l3E+00 5.79E-0l 2.77E+02 l.83E+00 9.39E-0l l.38E+02 9.l2E-0l 4.67E-0l l.43E+02 9.45E-0l 4.84E-0l 3.35E+02 2.22E+00 l.l4E+00 2.95E+02 l.96E+00 l.00E+00 30

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF l.77E+02 0.0017 0.0051 0.0001 0.0000 0.00ll 0.0080 l.52E+02 0.0014 0.0043 0.0001 0.0000 0.0010 0.0068 l.98E+02 0.0019 0.0057 0.0001 0.0000 0.0013 0.0089 l.67E+02 0.0016 0.0048 0.0001 0.0000 0.00ll 0.0075 8.08E+0l 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 l.29E+02 0.0012 0.0037 0.0000 0.0000 0.0008 0.0058 2.02E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0091 l.77E+02 0.0017 0.0051 0.0001 0.0000 0.00ll 0.0080 l.l6E+02 0.00ll 0.0033 0.0000 0.0000 0.0007 0.0052 2.48E+02 0.0024 0.0071 0.0001 0.0001 0.0016 0.0112 l.99E+02 0.0019 0.0057 0.0001 0.0000 0.0013 0.0090 l.64E+02 0.0016 0.0047 0.0001 0.0000 0.0010 0.0074 2.23E+02 0.0021 0.0064 0.0001 0.0000 0.0014 0.0101 l.l6E+02 0.00ll 0.0033 0.0000 0.0000 0.0007 0.0052 9.99E+0l 0.0009 0.0029 0.0000 0.0000 0.0006 0.0045 l.29E+02 0.0012 0.0037 0.0000 0.0000 0.0008 0.0058 2.70E+02 0.0026 0.0077 0.0001 0.0001 0.0017 0.0122 l.84E+02 0.0017 0.0053 0.0001 0.0000 0.0012 0.0083 8.58E+0l 0.0008 0.0025 0.0000 0.0000 0.0005 0.0039 l.39E+02 0.0013 0.0040 0.0001 0.0000 0.0009 0.0063 6.9lE+0l 0.0007 0.0020 0.0000 0.0000 0.0004 0.0031 7.l6E+0l 0.0007 0.0021 0.0000 0.0000 0.0005 0.0032 l.68E+02 0.0016 0.0048 0.0001 0.0000 0.00ll 0.0076 l.48E+02 0.0014 0.0043 0.0001 0.0000 0.0009 0.0067

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

804 56 3.99E+00 s

805 0

0.00E+00 s

806 171 l.22E+0l s

807 31 2.19E+00 s

808 527 3.76E+0l s

809 128 9.15E+00 s

810 180 l.29E+0l s

8ll 146 l.04E+0l s

812 258 l.84E+0l s

813 63 4.51E+00 s

814 269 l.92E+0l s

815 90 6.44E+00 s

816 175 l.25E+0l s

817 0

0.00E+00 s

818 0

0.00E+00 s

819 0

0.00E+00 s

820 0

0.00E+00 s

821 0

0.00E+00 s

822 0

0.00E+00 s

823 0

0.00E+00 s

824 0

0.00E+00 s

825 0

0.00E+00 s

826 0

0.00E+00 s

827 0

0.00E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 5.14E+0l 3.41E-0l l.74E-0l 0.00E+00 0.00E+00 0.00E+00 l.58E+02 l.04E+00 5.34E-0l 2.82E+0l l.87E-0l 9.56E-02 4.84E+02 3.21E+00 l.64E+00 l.l8E+02 7.80E-0l 3.99E-0l l.66E+02 l.l0E+00 5.62E-0l l.34E+02 8.90E-0l 4.55E-0l 2.37E+02 l.57E+00 8.04E-0l 5.81E+0l 3.84E-0l l.97E-0l 2.47E+02 l.64E+00 8.38E-0l 8.29E+0l 5.49E-0l 2.81E-0l l.61E+02 l.07E+00 5.45E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 31

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 2.58E+0l 0.0002 0.0007 0.0000 0.0000 0.0002 0.0012 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 7.91E+0l 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 l.42E+0l 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006 2.43E+02 0.0023 0.0070 0.0001 0.0001 0.0015 0.0ll0 5.91E+0l 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 8.33E+0l 0.0008 0.0024 0.0000 0.0000 0.0005 0.0038 6.74E+0l 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030 l.l9E+02 0.00ll 0.0034 0.0000 0.0000 0.0008 0.0054 2.91E+0l 0.0003 0.0008 0.0000 0.0000 0.0002 0.0013 l.24E+02 0.0012 0.0036 0.0000 0.0000 0.0008 0.0056 4.16E+0l 0.0004 0.0012 0.0000 0.0000 0.0003 0.0019 8.08E+0l 0.0008 0.0023 0.0000 0.0000 0.0005 0.0036 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

828 0

0.00E+00 s

829 0

0.00E+00 s

830 0

0.00E+00 s

831 0

0.00E+00 s

832 0

0.00E+00 s

833 0

0.00E+00 s

834 0

0.00E+00 s

835 0

0.00E+00 s

836 0

0.00E+00 s

837 0

0.00E+00 s

838 0

0.00E+00 s

839 0

0.00E+00 s

840 0

0.00E+00 s

841 0

0.00E+00 s

842 0

0.00E+00 s

843 0

0.00E+00 s

844 0

0.00E+00 s

845 7

5.15E-0l s

846 0

0.00E+00 s

847 0

0.00E+00 s

848 0

0.00E+00 s

849 0

0.00E+00 s

850 0

0.00E+00 s

851 0

0.00E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.63E+00 4.39E-02 2.25E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 32

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.33E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0002 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

852 0

0.00E+00 s

853 0

0.00E+00 s

854 0

0.00E+00 s

855 5

3.87E-0l s

856 52 3.74E+00 s

857 296 2.llE+0l s

858 60 4.25E+00 s

859 135 9.66E+00 s

860 32 2.32E+00 s

861 0

0.00E+00 s

862 47 3.35E+00 s

863 0

0.00E+00 s

864 32 2.32E+00 s

865 36 2.58E+00 s

866 0

0.00E+00 s

868 61 4.38E+00 s

869 56 3.99E+00 s

867 0

0.00E+00 s

870 45 3.22E+00 s

871 85 6.06E+00 s

872 85 6.06E+00 s

873 121 8.63E+00 s

874 36 2.58E+00 s

875 0

0.00E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.98E+00 3.30E-02 l.69E-02 4.81E+0l 3.l9E-0l l.63E-0l 2.72E+02 l.80E+00 9.22E-0l 5.47E+0l 3.62E-0l l.86E-0l l.24E+02 8.24E-0l 4.22E-0l 2.99E+0l l.98E-0l l.0lE-01 0.00E+00 0.00E+00 0.00E+00 4.31E+0l 2.86E-0l l.46E-0l 0.00E+00 0.00E+00 0.00E+00 2.99E+0l l.98E-0l l.0lE-01 3.32E+0l 2.20E-0l l.l2E-0l 0.00E+00 0.00E+00 0.00E+00 5.64E+0l 3.73E-0l l.91E-0l 5.l4E+0l 3.41E-0l l.74E-0l 0.00E+00 0.00E+00 0.00E+00 4.l5E+0l 2.75E-0l l.41E-0l 7.80E+0l 5.l6E-0l 2.64E-0l 7.80E+0l 5.l6E-0l 2.64E-0l l.llE+02 7.36E-0l 3.77E-0l 3.32E+0l 2.20E-0l l.l2E-0l 0.00E+00 0.00E+00 0.00E+00 33

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.50E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0001 2.41E+0l 0.0002 0.0007 0.0000 0.0000 0.0002 0.00ll l.37E+02 0.0013 0.0039 0.0001 0.0000 0.0009 0.0062 2.75E+0l 0.0003 0.0008 0.0000 0.0000 0.0002 0.0012 6.25E+0l 0.0006 0.0018 0.0000 0.0000 0.0004 0.0028 l.S0E+0l 0.0001 0.0004 0.0000 0.0000 0.0001 0.0007 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.l6E+0l 0.0002 0.0006 0.0000 0.0000 0.0001 0.0010 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 l.S0E+0l 0.0001 0.0004 0.0000 0.0000 0.0001 0.0007 l.67E+0l 0.0002 0.0005 0.0000 0.0000 0.0001 0.0008 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.83E+0l 0.0003 0.0008 0.0000 0.0000 0.0002 0.0013 2.58E+0l 0.0002 0.0007 0.0000 0.0000 0.0002 0.0012 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.08E+0l 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 3.91E+0l 0.0004 0.00ll 0.0000 0.0000 0.0002 0.0018 3.91E+0l 0.0004 0.00ll 0.0000 0.0000 0.0002 0.0018 5.58E+0l 0.0005 0.0016 0.0000 0.0000 0.0004 0.0025 l.67E+0l 0.0002 0.0005 0.0000 0.0000 0.0001 0.0008 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

876 0

0.00E+00 s

877 0

0.00E+00 s

878 0

0.00E+00 s

879 14 l.03E+00 s

880 0

0.00E+00 s

881 43 3.09E+00 s

882 0

0.00E+00 s

883 0

0.00E+00 s

884 0

0.00E+00 s

885 0

0.00E+00 s

886 0

0.00E+00 s

887 0

0.00E+00 s

888 0

0.00E+00 s

889 0

0.00E+00 s

890 0

0.00E+00 s

891 0

0.00E+00 s

892 0

0.00E+00 s

893 0

0.00E+00 s

894 0

0.00E+00 s

895 0

0.00E+00 s

896 0

0.00E+00 s

897 0

0.00E+00 s

898 0

0.00E+00 s

899 0

0.00E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.33E+0l 8.79E-02 4.50E-02 0.00E+00 0.00E+00 0.00E+00 3.98E+0l 2.64E-0l l.35E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 34

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 6.66E+00 0.0001 0.0002 0.0000 0.0000 0.0000 0.0003 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.00E+0l 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

COi 0

O.OOE+OO s

CO2 0

O.OOE+OO s

C03 0

O.OOE+OO s

C04 0

O.OOE+OO s

cos 0

O.OOE+OO s

C06 0

O.OOE+OO s

C07 0

O.OOE+OO s

cos 0

O.OOE+OO s

C09 0

O.OOE+OO s

CIO 0

O.OOE+OO s

Cll 0

O.OOE+OO s

Cl2 0

O.OOE+OO s

Cl3 0

O.OOE+OO s

Cl4 0

O.OOE+OO s

Cl5 0

O.OOE+OO s

Cl6 0

O.OOE+OO s

Cl7 0

O.OOE+OO s

Cl8 0

O.OOE+OO s

Cl9 0

O.OOE+OO s

C20 0

O.OOE+OO s

C21 0

O.OOE+OO s

C22 0

O.OOE+OO s

C23 0

O.OOE+OO s

C24 0

O.OOE+OO Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 35

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 O.OOE+OO 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

C25 0

0.00E+00 s

C26 0

0.00E+00 s

C27 0

0.00E+00 s

C28 0

0.00E+00 s

C29 0

0.00E+00 s

C30 0

0.00E+00 s

C31 0

0.00E+00 s

C32 0

0.00E+00 s

C33 0

0.00E+00 s

C34 0

0.00E+00 s

C35 0

0.00E+00 s

C36 0

0.00E+00 s

C37 0

0.00E+00 s

C38 0

0.00E+00 s

C39 0

0.00E+00 s

C40 112 7.99E+00 s

C41 0

0.00E+00 s

C42 0

0.00E+00 s

C43 0

0.00E+00 s

C44 0

0.00E+00 s

C45 0

0.00E+00 s

C46 0

0.00E+00 s

C47 0

0.00E+00 s

C48 0

0.00E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.03E+02 6.81E-0l 3.49E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 36

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 5.16E+0l 0.0005 0.0015 0.0000 0.0000 0.0003 0.0023 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

C49 0

0.00E+00 s

C50 58 4.12E+00 s

C51 36 2.58E+00 s

C52 152 l.08E+0l s

C53 0

0.00E+00 s

C54 43 3.09E+00 s

C55 0

0.00E+00 s

C56 47 3.35E+00 s

C57 0

0.00E+00 s

C58 63 4.51E+00 s

C59 240 l.71E+0l s

C60 81 5.80E+00 s

C61 211 l.51E+0l s

C62 83 5.93E+00 s

C63 0

0.00E+00 s

C64 137 9.79E+00 s

C65 31 2.19E+00 s

C66 96 6.83E+00 s

C67 0

0.00E+00 s

C68 0

0.00E+00 s

C69 31 2.19E+00 s

C70 101 7.22E+00 s

C71 229 l.64E+0l s

en 249 l.78E+0l Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 5.31E+0l 3.52E-0l l.80E-0l 3.32E+0l 2.20E-0l l.l2E-0l l.39E+02 9.23E-0l 4.72E-0l 0.00E+00 0.00E+00 0.00E+00 3.98E+0l 2.64E-0l l.35E-0l 0.00E+00 0.00E+00 0.00E+00 4.31E+0l 2.86E-0l l.46E-0l 0.00E+00 0.00E+00 0.00E+00 5.81E+0l 3.84E-0l l.97E-0l 2.21E+02 l.46E+00 7.48E-0l 7.46E+0l 4.94E-0l 2.53E-0l l.94E+02 l.29E+00 6.58E-0l 7.63E+0l 5.05E-0l 2.59E-0l 0.00E+00 0.00E+00 0.00E+00 l.26E+02 8.35E-0l 4.27E-0l 2.82E+0l l.87E-0l 9.56E-02 8.79E+0l 5.82E-0l 2.98E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.82E+0l l.87E-0l 9.56E-02 9.29E+0l 6.15E-0l 3.15E-0l 2.llE+02 l.40E+00 7.14E-0l 2.29E+02 l.52E+00 7.76E-0l 37

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.66E+0l 0.0003 0.0008 0.0000 0.0000 0.0002 0.0012 l.67E+0l 0.0002 0.0005 0.0000 0.0000 0.0001 0.0008 6.99E+0l 0.0007 0.0020 0.0000 0.0000 0.0004 0.0032 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.00E+0l 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.16E+0l 0.0002 0.0006 0.0000 0.0000 0.0001 0.0010 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.91E+0l 0.0003 0.0008 0.0000 0.0000 0.0002 0.0013 l.llE+02 0.0011 0.0032 0.0000 0.0000 0.0007 0.0050 3.75E+0l 0.0004 0.0011 0.0000 0.0000 0.0002 0.0017 9.74E+0l 0.0009 0.0028 0.0000 0.0000 0.0006 0.0044 3.83E+0l 0.0004 0.0011 0.0000 0.0000 0.0002 0.0017 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 6.33E+0l 0.0006 0.0018 0.0000 0.0000 0.0004 0.0029 l.42E+0l 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006 4.41E+0l 0.0004 0.0013 0.0000 0.0000 0.0003 0.0020 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 l.42E+0l 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006 4.66E+0l 0.0004 0.0013 0.0000 0.0000 0.0003 0.0021 l.06E+02 0.0010 0.0030 0.0000 0.0000 0.0007 0.0048 l.l5E+02 0.0011 0.0033 0.0000 0.0000 0.0007 0.0052

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

C73 440 3.14E+0l s

C74 352 2.51E+0l s

C75 438 3.l3E+0l s

C76 135 9.66E+00 s

C77 0

0.00E+00 s

C78 5

3.87E-0l s

C79 0

0.00E+00 s

C80 0

0.00E+00 s

C81 139 9.92E+00 s

C82 0

0.00E+00 s

C83 0

0.00E+00 s

C84 0

0.00E+00 s

C85 0

0.00E+00 s

C86 0

0.00E+00 s

C87 49 3.48E+00 s

C88 0

0.00E+00 s

C89 0

0.00E+00 s

C90 0

0.00E+00 s

C91 134 9.54E+00 s

C92 0

0.00E+00 s

C93 0

0.00E+00 s

C94 0

0.00E+00 s

C95 0

0.00E+00 s

C96 0

0.00E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 4.05E+02 2.68E+00 l.37E+00 3.23E+02 2.14E+00 l.l0E+00 4.03E+02 2.67E+00 l.37E+00 l.24E+02 8.24E-0l 4.22E-0l 0.00E+00 0.00E+00 0.00E+00 4.98E+00 3.30E-02 l.69E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.28E+02 8.46E-0l 4.33E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.48E+0l 2.97E-0l l.52E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.23E+02 8.l3E-0l 4.16E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 38

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 2.03E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0092 l.62E+02 0.0015 0.0047 0.0001 0.0000 0.0010 0.0073 2.02E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0091 6.25E+0l 0.0006 0.0018 0.0000 0.0000 0.0004 0.0028 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.50E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0001 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 6.41E+0l 0.0006 0.0018 0.0000 0.0000 0.0004 0.0029 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.25E+0l 0.0002 0.0006 0.0000 0.0000 0.0001 0.0010 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 6.16E+0l 0.0006 0.0018 0.0000 0.0000 0.0004 0.0028 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

C97 0

0.00E+00 s

C98 0

0.00E+00 s

C99 0

0.00E+00 s

DOI II 7.73E-0l s

002 0

0.00E+00 s

003 229 l.64E+0l s

004 65 4.64E+00 s

005 137 9.79E+00 s

006 119 8.50E+00 s

007 204 l.46E+0l s

008 285 2.04E+0l s

009 382 2.73E+0l s

D10 350 2.50E+0l s

Oil 482 3.44E+0l s

D12 343 2.45E+0l s

013 388 2.77E+0l s

014 417 2.98E+0l s

D15 660 4.72E+0l s

D16 615 4.39E+0l s

017 523 3.74E+0l s

D18 446 3.18E+0l s

D19 604 4.32E+0l s

D20 590 4.21E+0l s

D21 711 5.08E+0l Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.95E+00 6.59E-02 3.37E-02 0.00E+00 0.00E+00 0.00E+00 2.IIE+02 l.40E+00 7.14E-0l 5.97E+0l 3.95E-0l 2.02E-0l l.26E+02 8.35E-0l 4.27E-0l l.09E+02 7.25E-0l 3.71E-0l l.87E+02 l.24E+00 6.35E-0l 2.62E+02 l.74E+00 8.88E-0l 3.52E+02 2.33E+00 l.19E+00 3.22E+02 2.13E+00 l.09E+00 4.43E+02 2.93E+00 l.50E+00 3.15E+02 2.09E+00 l.07E+00 3.57E+02 2.36E+00 1.21E+00 3.83E+02 2.54E+00 l.30E+00 6.07E+02 4.02E+00 2.06E+00 5.66E+02 3.75E+00 l.92E+00 4.81E+02 3.19E+00 l.63E+00 4.10E+02 2.71E+00 l.39E+00 5.56E+02 3.68E+00 l.88E+00 5.42E+02 3.59E+00 l.84E+00 6.54E+02 4.33E+00 2.22E+00 39

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 5.00E+00 0.0000 0.0001 0.0000 0.0000 0.0000 0.0002 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 l.06E+02 0.0010 0.0030 0.0000 0.0000 0.0007 0.0048 3.00E+0l 0.0003 0.0009 0.0000 0.0000 0.0002 0.0014 6.33E+0l 0.0006 0.0018 0.0000 0.0000 0.0004 0.0029 5.50E+0l 0.0005 0.0016 0.0000 0.0000 0.0003 0.0025 9.41E+0l 0.0009 0.0027 0.0000 0.0000 0.0006 0.0042 l.32E+02 0.0012 0.0038 0.0000 0.0000 0.0008 0.0059 l.77E+02 0.0017 0.0051 0.0001 0.0000 0.0011 0.0080 l.62E+02 0.0015 0.0046 0.0001 0.0000 0.0010 0.0073 2.22E+02 0.0021 0.0064 0.0001 0.0000 0.0014 0.0100 l.58E+02 0.0015 0.0045 0.0001 0.0000 0.0010 0.0071 l.79E+02 0.0017 0.0051 0.0001 0.0000 0.0011 0.0081 l.92E+02 0.0018 0.0055 0.0001 0.0000 0.0012 0.0087 3.05E+02 0.0029 0.0087 0.0001 0.0001 0.0019 0.0137 2.84E+02 0.0027 0.0082 0.0001 0.0001 0.0018 0.0128 2.41E+02 0.0023 0.0069 0.0001 0.0000 0.0015 0.0109 2.06E+02 0.0020 0.0059 0.0001 0.0000 0.0013 0.0093 2.79E+02 0.0026 0.0080 0.0001 0.0001 0.0018 0.0126 2.72E+02 0.0026 0.0078 0.0001 0.0001 0.0017 0.0123 3.28E+02 0.0031 0.0094 0.0001 0.0001 0.0021 0.0148

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

D22 722 5.15E+0l s

D23 1046 7.47E+0l s

D24 933 6.66E+0l s

D25 814 5.8lE+0l s

D26 893 6.38E+0l s

D27 585 4.17E+0l s

D28 673 4.8lE+0l s

D29 610 4.36E+0l s

030 742 5.30E+0l s

031 613 4.38E+0l s

032 1037 7.4lE+0l s

033 814 5.8lE+0l s

034 852 6.08E+0l s

035 567 4.05E+0l s

036 806 5.76E+0l s

037 926 6.6lE+0l s

038 700 5.00E+0l s

039 1030 7.36E+0l s

040 817 5.84E+0l s

041 678 4.84E+0l s

042 318 2.27E+0l s

043 512 3.66E+0l s

044 494 3.53E+0l s

045 561 4.0lE+0l Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 6.63E+02 4.39E+00 2.25E+00 9.62E+02 6.37E+00 3.26E+00 8.58E+02 5.68E+00 2.9lE+00 7.48E+02 4.95E+00 2.54E+00 8.21E+02 5.44E+00 2.78E+00 5.37E+02 3.56E+00 l.82E+00 6.19E+02 4.I0E+00 2.I0E+00 5.61E+02 3.7lE+00 l.90E+00 6.82E+02 4.5lE+00 2.3lE+00 5.64E+02 3.73E+00 l.9lE+00 9.54E+02 6.32E+00 3.23E+00 7.48E+02 4.95E+00 2.54E+00 7.83E+02 5.18E+00 2.65E+00 5.21E+02 3.45E+00 l.77E+00 7.41E+02 4.9lE+00 2.5lE+00 8.51E+02 5.64E+00 2.88E+00 6.44E+02 4.26E+00 2.18E+00 9.47E+02 6.27E+00 3.2lE+00 7.51E+02 4.98E+00 2.55E+00 6.24E+02 4.l3E+00 2.llE+00 2.92E+02 l.93E+00 9.90E-0l 4.71E+02 3.12E+00 l.60E+00 4.54E+02 3.0lE+00 l.54E+00 5.16E+02 3.42E+00 l.75E+00 40

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 3.33E+02 0.0032 0.0096 0.0001 0.0001 0.0021 0.0150 4.83E+02 0.0046 0.0139 0.0002 0.0001 0.0031 0.0218 4.30E+02 0.0041 0.0124 0.0002 0.0001 0.0027 0.0194 3.76E+02 0.0036 0.0108 0.0001 0.0001 0.0024 0.0169 4.12E+02 0.0039 0.0118 0.0002 0.0001 0.0026 0.0186 2.70E+02 0.0026 0.0077 0.0001 0.0001 0.0017 0.0122 3.llE+02 0.0029 0.0089 0.0001 0.0001 0.0020 0.0140 2.81E+02 0.0027 0.0081 0.0001 0.0001 0.0018 0.0127 3.42E+02 0.0032 0.0098 0.0001 0.0001 0.0022 0.0154 2.83E+02 0.0027 0.0081 0.0001 0.0001 0.0018 0.0128 4.79E+02 0.0045 0.0137 0.0002 0.0001 0.0030 0.0216 3.76E+02 0.0036 0.0108 0.0001 0.0001 0.0024 0.0169 3.93E+02 0.0037 0.0113 0.0001 0.0001 0.0025 0.0177 2.61E+02 0.0025 0.0075 0.0001 0.0001 0.0017 0.0118 3.72E+02 0.0035 0.0107 0.0001 0.0001 0.0024 0.0168 4.27E+02 0.0041 0.0123 0.0002 0.0001 0.0027 0.0193 3.23E+02 0.0031 0.0093 0.0001 0.0001 0.0020 0.0146 4.75E+02 0.0045 0.0136 0.0002 0.0001 0.0030 0.0214 3.77E+02 0.0036 0.0108 0.0001 0.0001 0.0024 0.0170 3.l3E+02 0.0030 0.0090 0.0001 0.0001 0.0020 0.0141 l.47E+02 0.0014 0.0042 0.0001 0.0000 0.0009 0.0066 2.36E+02 0.0022 0.0068 0.0001 0.0000 0.0015 0.0107 2.28E+02 0.0022 0.0065 0.0001 0.0000 0.0014 0.0103 2.59E+02 0.0025 0.0074 0.0001 0.0001 0.0016 0.0117

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

046 437 3.12E+0l s

047 543 3.88E+0l s

048 350 2.50E+0l s

049 290 2.07E+0l s

D50 74 5.28E+00 s

D51 200 l.43E+0l s

D52 143 l.02E+0l s

D53 119 8.50E+00 s

D54 189 l.35E+0l s

D55 146 l.04E+0l s

D56 236 l.69E+0l s

D57 184 l.31E+0l s

D58 31 2.19E+00 s

D59 16 l.l6E+00 s

D60 130 9.28E+00 s

D61 92 6.57E+00 s

D62 83 5.93E+00 s

D63 161 l.l5E+0l s

D64 229 l.64E+0l s

D65 240 l.71E+0l s

D66 310 2.22E+0l s

D67 148 l.06E+0l s

D68 303 2.16E+0l s

D69 85 6.06E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 4.0IE+02 2.66E+00 l.36E+00 4.99E+02 3.31E+00 l.69E+00 3.22E+02 2.l3E+00 l.09E+00 2.67E+02 l.77E+00 9.05E-0l 6.80E+0l 4.50E-0l 2.31E-0l l.84E+02 l.22E+00 6.24E-0l l.31E+02 8.68E-0l 4.44E-0l l.09E+02 7.25E-0l 3.71E-0l l.74E+02 l.l5E+00 5.90E-0l l.34E+02 8.90E-0l 4.55E-0l 2.17E+02 l.44E+00 7.37E-0l l.69E+02 l.l2E+00 5.73E-0l 2.82E+0l l.87E-0l 9.56E-02 l.49E+0l 9.89E-02 5.06E-02 l.l9E+02 7.91E-0l 4.05E-0l 8.46E+0l 5.60E-0l 2.87E-0l 7.63E+0l 5.05E-0l 2.59E-0l l.48E+02 9.78E-0l 5.00E-01 2.llE+02 l.40E+00 7.14E-0l 2.21E+02 l.46E+00 7.48E-0l 2.85E+02 l.89E+00 9.67E-0l l.36E+02 9.0IE-01 4.61E-0l 2.79E+02 l.85E+00 9.45E-0l 7.80E+0l 5.16E-0l 2.64E-0l 41

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 2.02E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0091 2.51E+02 0.0024 0.0072 0.0001 0.0001 0.0016 0.0113 l.62E+02 0.0015 0.0046 0.0001 0.0000 0.0010 0.0073 l.34E+02 0.0013 0.0038 0.0001 0.0000 0.0008 0.0060 3.41E+0l 0.0003 0.0010 0.0000 0.0000 0.0002 0.0015 9.24E+0l 0.0009 0.0027 0.0000 0.0000 0.0006 0.0042 6.58E+0l 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030 5.50E+0l 0.0005 0.0016 0.0000 0.0000 0.0003 0.0025 8.74E+0l 0.0008 0.0025 0.0000 0.0000 0.0006 0.0039 6.74E+0l 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030 l.09E+02 0.0010 0.0031 0.0000 0.0000 0.0007 0.0049 8.49E+0l 0.0008 0.0024 0.0000 0.0000 0.0005 0.0038 l.42E+0l 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006 7.49E+00 0.0001 0.0002 0.0000 0.0000 0.0000 0.0003 6.00E+0l 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 4.25E+0l 0.0004 0.0012 0.0000 0.0000 0.0003 0.0019 3.83E+0l 0.0004 0.0011 0.0000 0.0000 0.0002 0.0017 7.41E+0l 0.0007 0.0021 0.0000 0.0000 0.0005 0.0033 l.06E+02 0.0010 0.0030 0.0000 0.0000 0.0007 0.0048 l.llE+02 0.0011 0.0032 0.0000 0.0000 0.0007 0.0050 l.43E+02 0.0014 0.0041 0.0001 0.0000 0.0009 0.0065 6.83E+0l 0.0006 0.0020 0.0000 0.0000 0.0004 0.0031 l.40E+02 0.0013 0.0040 0.0001 0.0000 0.0009 0.0063 3.91E+0l 0.0004 0.0011 0.0000 0.0000 0.0002 0.0018

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

070 242 l.73E+0l s

071 81 5.80E+00 s

072 0

0.00E+00 s

073 312 2.23E+0l s

074 180 l.29E+0l s

075 197 l.40E+0l s

076 43 3.09E+00 s

077 0

0.00E+00 s

078 0

0.00E+00 s

079 128 9.l5E+00 s

080 390 2.78E+0l s

081 547 3.90E+0l s

082 493 3.52E+0l s

083 622 4.45E+0l s

084 622 4.45E+0l s

085 474 3.39E+0l s

086 529 3.78E+0l s

087 413 2.95E+0l s

088 298 2.l3E+0l s

089 772 5.52E+0l s

090 734 5.24E+0l s

091 873 6.24E+0l s

092 898 6.42E+0l s

093 761 5.44E+0l Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 2.22E+02 l.47E+00 7.53E-0l 7.46E+0l 4.94E-0l 2.53E-0l 0.00E+00 0.00E+00 0.00E+00 2.87E+02 l.90E+00 9.73E-0l l.66E+02 l.l0E+00 5.62E-0l l.81E+02 l.20E+00 6.l3E-0l 3.98E+0l 2.64E-0l l.35E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.18E+02 7.80E-0l 3.99E-0l 3.58E+02 2.37E+00 l.2lE+00 5.03E+02 3.33E+00 l.70E+00 4.53E+02 3.00E+00 l.53E+00 5.72E+02 3.79E+00 l.94E+00 5.72E+02 3.79E+00 l.94E+00 4.36E+02 2.89E+00 l.48E+00 4.86E+02 3.22E+00 l.65E+00 3.80E+02 2.52E+00 l.29E+00 2.74E+02 l.8lE+00 9.28E-0l 7.l0E+02 4.70E+00 2.4lE+00 6.75E+02 4.47E+00 2.29E+00 8.03E+02 5.32E+00 2.72E+00 8.26E+02 5.47E+00 2.80E+00 7.00E+02 4.64E+00 2.37E+00 42

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF l.12E+02 0.0011 0.0032 0.0000 0.0000 0.0007 0.0050 3.75E+0l 0.0004 0.0011 0.0000 0.0000 0.0002 0.0017 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 l.44E+02 0.0014 0.0041 0.0001 0.0000 0.0009 0.0065 8.33E+0l 0.0008 0.0024 0.0000 0.0000 0.0005 0.0038 9.08E+0l 0.0009 0.0026 0.0000 0.0000 0.0006 0.0041 2.00E+0l 0.0002 0.0006 0.0000 0.0000 0.0001 0.0009 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 5.9lE+0l 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 l.80E+02 0.0017 0.0052 0.0001 0.0000 0.0011 0.0081 2.52E+02 0.0024 0.0072 0.0001 0.0001 0.0016 0.0114 2.27E+02 0.0022 0.0065 0.0001 0.0000 0.0014 0.0103 2.87E+02 0.0027 0.0082 0.0001 0.0001 0.0018 0.0130 2.87E+02 0.0027 0.0082 0.0001 0.0001 0.0018 0.0130 2.l9E+02 0.0021 0.0063 0.0001 0.0000 0.0014 0.0099 2.44E+02 0.0023 0.0070 0.0001 0.0001 0.0015 0.0110 l.91E+02 0.0018 0.0055 0.0001 0.0000 0.0012 0.0086 l.37E+02 0.0013 0.0039 0.0001 0.0000 0.0009 0.0062 3.56E+02 0.0034 0.0102 0.0001 0.0001 0.0023 0.0161 3.39E+02 0.0032 0.0097 0.0001 0.0001 0.0021 0.0153 4.03E+02 0.0038 0.0116 0.0002 0.0001 0.0026 0.0182 4.l5E+02 0.0039 0.0119 0.0002 0.0001 0.0026 0.0187 3.5lE+02 0.0033 0.0101 0.0001 0.0001 0.0022 0.0159

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

094 810 5.79E+0l s

095 579 4.l4E+0l s

096 244 l.74E+0l s

097 648 4.63E+0l s

098 628 4.48E+0l s

099 74 5.28E+00 s

E0l 60 4.25E+00 s

E02 0

0.00E+00 s

E03 137 9.79E+00 s

E04 0

0.00E+00 s

E05 0

0.00E+00 s

E06 0

0.00E+00 s

E07 112 7.99E+00 s

E08 0

0.00E+00 s

E09 363 2.59E+0l s

El0 364 2.60E+0l s

Ell 438 3.l3E+0l s

El2 920 6.57E+0l s

El3 1019 7.28E+0l s

El4 1102 7.87E+0l s

El5 1131 8.08E+0l s

El6 1155 8.25E+0l s

El7 2324 l.66E+02 s

El8 4014 2.87E+02 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 7.45E+02 4.93E+00 2.52E+00 5.32E+02 3.53E+00 l.80E+00 2.24E+02 l.48E+00 7.59E-0l 5.95E+02 3.94E+00 2.02E+00 5.77E+02 3.82E+00 l.96E+00 6.80E+0l 4.50E-0l 2.31E-0l 5.47E+0l 3.62E-0l l.86E-0l 0.00E+00 0.00E+00 0.00E+00 l.26E+02 8.35E-0l 4.27E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.03E+02 6.81E-0l 3.49E-0l 0.00E+00 0.00E+00 0.00E+00 3.33E+02 2.2lE+00 l.l3E+00 3.35E+02 2.22E+00 l.l4E+00 4.03E+02 2.67E+00 l.37E+00 8.46E+02 5.60E+00 2.87E+00 9.37E+02 6.2lE+00 3.l8E+00 l.0lE+03 6.7lE+00 3.44E+00 l.04E+03 6.89E+00 3.53E+00 l.06E+03 7.03E+00 3.60E+00 2.l4E+03 l.4lE+0l 7.24E+00 3.69E+03 2.44E+0l l.25E+0l 43

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 3.74E+02 0.0035 0.0107 0.0001 0.0001 0.0024 0.0169 2.67E+02 0.0025 0.0077 0.0001 0.0001 0.0017 0.0121 l.l2E+02 0.0011 0.0032 0.0000 0.0000 0.0007 0.0051 2.99E+02 0.0028 0.0086 0.0001 0.0001 0.0019 0.0135 2.90E+02 0.0028 0.0083 0.0001 0.0001 0.0018 0.0131 3.4lE+0l 0.0003 0.0010 0.0000 0.0000 0.0002 0.0015 2.75E+0l 0.0003 0.0008 0.0000 0.0000 0.0002 0.0012 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 6.33E+0l 0.0006 0.0018 0.0000 0.0000 0.0004 0.0029 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 5.l6E+0l 0.0005 0.0015 0.0000 0.0000 0.0003 0.0023 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 l.67E+02 0.0016 0.0048 0.0001 0.0000 0.0011 0.0075 l.68E+02 0.0016 0.0048 0.0001 0.0000 0.0011 0.0076 2.02E+02 0.0019 0.0058 0.0001 0.0000 0.0013 0.0091 4.25E+02 0.0040 0.0122 0.0002 0.0001 0.0027 0.0192 4.70E+02 0.0045 0.0135 0.0002 0.0001 0.0030 0.0212 5.09E+02 0.0048 0.0146 0.0002 0.0001 0.0032 0.0229 5.22E+02 0.0050 0.0150 0.0002 0.0001 0.0033 0.0236 5.33E+02 0.0051 0.0153 0.0002 0.0001 0.0034 0.0240 l.07E+03 0.0102 0.0308 0.0004 0.0002 0.0068 0.0484 l.85E+03 0.0176 0.0532 0.0007 0.0004 0.0117 0.0836

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 s

El9 4687 3.35E+02 s

E20 4738 3.38E+02 s

E21 4561 3.26E+02 s

E22 4458 3.18E+02 s

E23 4624 3.30E+02 s

E24 4765 3.40E+02 s

E25 4725 3.37E+02 Q

A05QC 0

0.00E+00 Q

Al2QC 0

0.00E+00 Q

A34QC 0

0.00E+00 Q

A40QC 0

0.00E+00 Q

A47QC 0

0.00E+00 Q

A66QC 0

0.00E+00 Q

A76QC 122 8.72E+00 Q

A95QC 295 2.IIE+0l Q

A97QC 246 l.76E+0l Q

B20QC 0

0.00E+00 Q

C06QC 0

0.00E+00 Q

C24QC 0

0.00E+00 Q

C42QC 142 l.0IE+0l Q

C56QC 15 l.04E+00 Q

C67QC 0

0.00E+00 Q

C85QC 0

0.00E+00 Q

C89QC 27 l.95E+00 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 4.31E+03 2.85E+0l l.46E+0l 4.36E+03 2.88E+0l l.48E+0l 4.19E+03 2.78E+0l l.42E+0l 4.I0E+03 2.71E+0l l.39E+0l 4.25E+03 2.82E+0l l.44E+0l 4.38E+03 2.90E+0l l.48E+0l 4.34E+03 2.88E+0l l.47E+0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.12E+02 7.43E-0l 3.80E-0l 2.71E+02 l.80E+00 9.20E-0l 2.26E+02 l.50E+00 7.67E-0l 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 l.31E+02 8.65E-0l 4.43E-0l l.34E+0l 8.87E-02 4.54E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.51E+0l l.66E-0l 8.52E-02 44

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 2.16E+03 0.0205 0.0621 0.0008 0.0004 0.0137 0.0976 2.19E+03 0.0208 0.0628 0.0008 0.0005 0.0138 0.0986 2.I0E+03 0.0200 0.0604 0.0008 0.0004 0.0133 0.0950 2.06E+03 0.0195 0.0591 0.0008 0.0004 0.0130 0.0928 2.l3E+03 0.0203 0.0613 0.0008 0.0004 0.0135 0.0963 2.20E+03 0.0209 0.0631 0.0008 0.0005 0.0139 0.0992 2.18E+03 0.0207 0.0626 0.0008 0.0005 0.0138 0.0984 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 5.63E+0l 0.0005 0.0016 0.0000 0.0000 0.0004 0.0025 l.36E+02 0.0013 0.0039 0.0001 0.0000 0.0009 0.0061 l.14E+02 0.0011 0.0033 0.0000 0.0000 0.0007 0.0051 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 6.56E+0l 0.0006 0.0019 0.0000 0.0000 0.0004 0.0030 6.73E+00 0.0001 0.0002 0.0000 0.0000 0.0000 0.0003 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00E+00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 l.26E+0l 0.0001 0.0004 0.0000 0.0000 0.0001 0.0006

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Measurement Gamma Result Population Measurement ID dpm/100 cm2 Co-60 Q

C90QC 128 9.IIE+00 Q

D32QC 802 5.73E+0l Q

D79QC 157 l.12E+0l Q

E03QC 51 3.64E+00 Q

El4QC 191 l.37E+0l Q

El9QC 2434 l.74E+02 Q

E20QC 3194 2.28E+02 Q

E24QC 4407 3.l5E+02 J

K0lBiased 5869 4.l9E+02 J

K02Biased 6056 4.33E+02 Activity' (dpm/100 cm2)

Cs-137 Eu-152 Eu-154 l.17E+02 7.77E-0l 3.97E-0l 7.37E+02 4.88E+00 2.50E+00 l.44E+02 9.54E-0l 4.88E-0l 4.69E+0l 3.IIE-01 l.59E-0l l.76E+02 l.16E+00 5.96E-0l 2.24E+03 l.48E+0l 7.59E+00 2.94E+03 l.94E+0l 9.95E+00 4.05E+03 2.68E+0l l.37E+0l 5.40E+03 3.57E+0l l.83E+0l 5.57E+03 3.69E+0l l.89E+0l 45

~

LACROSSESOLUTIONS Fraction ofOpDCGL Measurement Sr-90 Co-60 Cs-137 Eu-152 Eu-154 Sr-90 OpSOF 5.89E+0l 0.0006 0.0017 0.0000 0.0000 0.0004 0.0027 3.70E+02 0.0035 0.0106 0.0001 0.0001 0.0023 0.0167 7.23E+0l 0.0007 0.0021 0.0000 0.0000 0.0005 0.0033 2.35E+0l 0.0002 0.0007 0.0000 0.0000 0.0001 0.0011 8.83E+0l 0.0008 0.0025 0.0000 0.0000 0.0006 0.0040 l.12E+03 0.0107 0.0322 0.0004 0.0002 0.0071 0.0507 l.47E+03 0.0140 0.0423 0.0006 0.0003 0.0093 0.0665 2.03E+03 0.0193 0.0584 0.0008 0.0004 0.0129 0.0918 2.71E+03 0,0257 0.0777 0.0010 0.0006 0.0171 0.1222 2.80E+03 0.0265 0.0802 0.0011 0.0006 0.0177 0.1261

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 46 ATTACHMENT 3 SIGN TEST

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 47 Table 16 Survey Unit S1-011-102 Sign Test SOF 1-Ws Sign (Ws) 1 0.0125 0.99

+1 2

0.0000 1.00

+1 3

0.0002 1.00

+1 4

0.0000 1.00

+1 5

0.0000 1.00

+1 6

0.0000 1.00

+1 7

0.0000 1.00

+1 8

0.0000 1.00

+1 9

0.0000 1.00

+1 10 0.0000 1.00

+1 11 0.0000 1.00

+1 12 0.0000 1.00

+1 13 0.0000 1.00

+1 14 0.0000 1.00

+1 15 0.0000 1.00

+1 16 0.0000 1.00

+1 17 0.0094 0.99

+1 18 0.0040 1.00

+1 19 0.0066 0.99

+1 20 0.0144 0.99

+1 21 0.0036 1.00

+1 22 0.0044 1.00

+1 23 0.0031 1.00

+1 24 0.0014 1.00

+1 25 0.0000 1.00

+1 26 0.0000 1.00

+1 27 0.0000 1.00

+1 28 0.0000 1.00

+1 29 0.0000 1.00

+1 30 0.0000 1.00

+1 31 0.0009 1.00

+1 32 0.0000 1.00

+1 33 0.0000 1.00

+1 34 0.0000 1.00

+1 35 0.0000 1.00

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 48 SOF 1-Ws Sign (Ws) 36 0.0000 1.00

+1 37 0.0000 1.00

+1 38 0.0000 1.00

+1 39 0.0000 1.00

+1 40 0.0000 1.00

+1 41 0.0000 1.00

+1 42 0.0000 1.00

+1 43 0.0000 1.00

+1 44 0.0000 1.00

+1 45 0.0000 1.00

+1 46 0.0000 1.00

+1 47 0.0000 1.00

+1 48 0.0000 1.00

+1 49 0.0038 1.00

+1 50 0.0000 1.00

+1 51 0.0012 1.00

+1 52 0.0000 1.00

+1 53 0.0000 1.00

+1 54 0.0004 1.00

+1 55 0.0002 1.00

+1 56 0.0015 1.00

+1 57 0.0030 1.00

+1 58 0.0000 1.00

+1 59 0.0003 1.00

+1 60 0.0000 1.00

+1 61 0.0088 0.99

+1 62 0.0014 1.00

+1 63 0.0045 1.00

+1 64 0.0036 1.00

+1 65 0.0140 0.99

+1 66 0.0148 0.99

+1 67 0.0183 0.98

+1 68 0.0136 0.99

+1 69 0.0107 0.99

+1 70 0.0117 0.99

+1 71 0.0101 0.99

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 49 SOF 1-Ws Sign (Ws) 72 0.0114 0.99

+1 73 0.0092 0.99

+1 74 0.0048 1.00

+1 75 0.0066 0.99

+1 76 0.0044 1.00

+1 77 0.0026 1.00

+1 78 0.0045 1.00

+1 79 0.0027 1.00

+1 80 0.0063 0.99

+1 81 0.0009 1.00

+1 82 0.0000 1.00

+1 83 0.0000 1.00

+1 84 0.0000 1.00

+1 85 0.0845 0.92

+1 86 0.1131 0.89

+1 87 0.1113 0.89

+1 88 0.0956 0.90

+1 89 0.0198 0.98

+1 90 0.0082 0.99

+1 91 0.0000 1.00

+1 92 0.0000 1.00

+1 93 0.0000 1.00

+1 94 0.0000 1.00

+1 95 0.0000 1.00

+1 96 0.0000 1.00

+1 97 0.0000 1.00

+1 98 0.0000 1.00

+1 99 0.0000 1.00

+1 100 0.0000 1.00

+1 101 0.0000 1.00

+1 102 0.0000 1.00

+1 103 0.0000 1.00

+1 104 0.0000 1.00

+1 105 0.0000 1.00

+1 106 0.0000 1.00

+1 107 0.0000 1.00

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 50 SOF 1-Ws Sign (Ws) 108 0.0000 1.00

+1 109 0.0000 1.00

+1 110 0.0000 1.00

+1 111 0.0000 1.00

+1 112 0.0000 1.00

+1 113 0.0000 1.00

+1 114 0.0000 1.00

+1 115 0.0000 1.00

+1 116 0.0000 1.00

+1 117 0.0000 1.00

+1 118 0.0000 1.00

+1 119 0.0000 1.00

+1 120 0.0000 1.00

+1 121 0.0000 1.00

+1 122 0.0000 1.00

+1 123 0.0000 1.00

+1 124 0.0000 1.00

+1 125 0.0000 1.00

+1 126 0.0000 1.00

+1 127 0.0000 1.00

+1 128 0.0000 1.00

+1 129 0.0000 1.00

+1 130 0.0000 1.00

+1 131 0.0000 1.00

+1 132 0.0000 1.00

+1 133 0.0000 1.00

+1 134 0.0000 1.00

+1 135 0.0000 1.00

+1 136 0.0000 1.00

+1 137 0.0000 1.00

+1 138 0.0000 1.00

+1 139 0.0000 1.00

+1 140 0.0000 1.00

+1 141 0.0000 1.00

+1 142 0.0000 1.00

+1 143 0.0000 1.00

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 51 SOF 1-Ws Sign (Ws) 144 0.0000 1.00

+1 145 0.0000 1.00

+1 146 0.0000 1.00

+1 147 0.0000 1.00

+1 148 0.0000 1.00

+1 149 0.0000 1.00

+1 150 0.0000 1.00

+1 151 0.0000 1.00

+1 152 0.0000 1.00

+1 153 0.0000 1.00

+1 154 0.0015 1.00

+1 155 0.0033 1.00

+1 156 0.0000 1.00

+1 157 0.0018 1.00

+1 158 0.0000 1.00

+1 159 0.0000 1.00

+1 160 0.0042 1.00

+1 161 0.0124 0.99

+1 162 0.0108 0.99

+1 163 0.0096 0.99

+1 164 0.0122 0.99

+1 165 0.0071 0.99

+1 166 0.0086 0.99

+1 167 0.0110 0.99

+1 168 0.0080 0.99

+1 169 0.0068 0.99

+1 170 0.0089 0.99

+1 171 0.0075 0.99

+1 172 0.0036 1.00

+1 173 0.0058 0.99

+1 174 0.0091 0.99

+1 175 0.0080 0.99

+1 176 0.0052 0.99

+1 177 0.0112 0.99

+1 178 0.0090 0.99

+1 179 0.0074 0.99

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 52 SOF 1-Ws Sign (Ws) 180 0.0101 0.99

+1 181 0.0052 0.99

+1 182 0.0045 1.00

+1 183 0.0058 0.99

+1 184 0.0122 0.99

+1 185 0.0083 0.99

+1 186 0.0039 1.00

+1 187 0.0063 0.99

+1 188 0.0031 1.00

+1 189 0.0032 1.00

+1 190 0.0076 0.99

+1 191 0.0067 0.99

+1 192 0.0012 1.00

+1 193 0.0000 1.00

+1 194 0.0036 1.00

+1 195 0.0006 1.00

+1 196 0.0110 0.99

+1 197 0.0027 1.00

+1 198 0.0038 1.00

+1 199 0.0030 1.00

+1 200 0.0054 0.99

+1 201 0.0013 1.00

+1 202 0.0056 0.99

+1 203 0.0019 1.00

+1 204 0.0036 1.00

+1 205 0.0000 1.00

+1 206 0.0000 1.00

+1 207 0.0000 1.00

+1 208 0.0000 1.00

+1 209 0.0000 1.00

+1 210 0.0000 1.00

+1 211 0.0000 1.00

+1 212 0.0000 1.00

+1 213 0.0000 1.00

+1 214 0.0000 1.00

+1 215 0.0000 1.00

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 53 SOF 1-Ws Sign (Ws) 216 0.0000 1.00

+1 217 0.0000 1.00

+1 218 0.0000 1.00

+1 219 0.0000 1.00

+1 220 0.0000 1.00

+1 221 0.0000 1.00

+1 222 0.0000 1.00

+1 223 0.0000 1.00

+1 224 0.0000 1.00

+1 225 0.0000 1.00

+1 226 0.0000 1.00

+1 227 0.0000 1.00

+1 228 0.0000 1.00

+1 229 0.0000 1.00

+1 230 0.0000 1.00

+1 231 0.0000 1.00

+1 232 0.0000 1.00

+1 233 0.0002 1.00

+1 234 0.0000 1.00

+1 235 0.0000 1.00

+1 236 0.0000 1.00

+1 237 0.0000 1.00

+1 238 0.0000 1.00

+1 239 0.0000 1.00

+1 240 0.0000 1.00

+1 241 0.0000 1.00

+1 242 0.0000 1.00

+1 243 0.0001 1.00

+1 244 0.0011 1.00

+1 245 0.0062 0.99

+1 246 0.0012 1.00

+1 247 0.0028 1.00

+1 248 0.0007 1.00

+1 249 0.0000 1.00

+1 250 0.0010 1.00

+1 251 0.0000 1.00

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 54 SOF 1-Ws Sign (Ws) 252 0.0007 1.00

+1 253 0.0008 1.00

+1 254 0.0000 1.00

+1 255 0.0013 1.00

+1 256 0.0012 1.00

+1 257 0.0000 1.00

+1 258 0.0009 1.00

+1 259 0.0018 1.00

+1 260 0.0018 1.00

+1 261 0.0025 1.00

+1 262 0.0008 1.00

+1 263 0.0000 1.00

+1 264 0.0000 1.00

+1 265 0.0000 1.00

+1 266 0.0000 1.00

+1 267 0.0003 1.00

+1 268 0.0000 1.00

+1 269 0.0009 1.00

+1 270 0.0000 1.00

+1 271 0.0000 1.00

+1 272 0.0000 1.00

+1 273 0.0000 1.00

+1 274 0.0000 1.00

+1 275 0.0000 1.00

+1 276 0.0000 1.00

+1 277 0.0000 1.00

+1 278 0.0000 1.00

+1 279 0.0000 1.00

+1 280 0.0000 1.00

+1 281 0.0000 1.00

+1 282 0.0000 1.00

+1 283 0.0000 1.00

+1 284 0.0000 1.00

+1 285 0.0000 1.00

+1 286 0.0000 1.00

+1 287 0.0000 1.00

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 55 SOF 1-Ws Sign (Ws) 288 0.0000 1.00

+1 289 0.0000 1.00

+1 290 0.0000 1.00

+1 291 0.0000 1.00

+1 292 0.0000 1.00

+1 293 0.0000 1.00

+1 294 0.0000 1.00

+1 295 0.0000 1.00

+1 296 0.0000 1.00

+1 297 0.0000 1.00

+1 298 0.0000 1.00

+1 299 0.0000 1.00

+1 300 0.0000 1.00

+1 301 0.0000 1.00

+1 302 0.0000 1.00

+1 303 0.0000 1.00

+1 304 0.0000 1.00

+1 305 0.0000 1.00

+1 306 0.0000 1.00

+1 307 0.0000 1.00

+1 308 0.0000 1.00

+1 309 0.0000 1.00

+1 310 0.0000 1.00

+1 311 0.0000 1.00

+1 312 0.0000 1.00

+1 313 0.0000 1.00

+1 314 0.0000 1.00

+1 315 0.0000 1.00

+1 316 0.0000 1.00

+1 317 0.0000 1.00

+1 318 0.0000 1.00

+1 319 0.0000 1.00

+1 320 0.0000 1.00

+1 321 0.0000 1.00

+1 322 0.0000 1.00

+1 323 0.0000 1.00

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 56 SOF 1-Ws Sign (Ws) 324 0.0000 1.00

+1 325 0.0000 1.00

+1 326 0.0000 1.00

+1 327 0.0023 1.00

+1 328 0.0000 1.00

+1 329 0.0000 1.00

+1 330 0.0000 1.00

+1 331 0.0000 1.00

+1 332 0.0000 1.00

+1 333 0.0000 1.00

+1 334 0.0000 1.00

+1 335 0.0000 1.00

+1 336 0.0000 1.00

+1 337 0.0012 1.00

+1 338 0.0008 1.00

+1 339 0.0032 1.00

+1 340 0.0000 1.00

+1 341 0.0009 1.00

+1 342 0.0000 1.00

+1 343 0.0010 1.00

+1 344 0.0000 1.00

+1 345 0.0013 1.00

+1 346 0.0050 1.00

+1 347 0.0017 1.00

+1 348 0.0044 1.00

+1 349 0.0017 1.00

+1 350 0.0000 1.00

+1 351 0.0029 1.00

+1 352 0.0006 1.00

+1 353 0.0020 1.00

+1 354 0.0000 1.00

+1 355 0.0000 1.00

+1 356 0.0006 1.00

+1 357 0.0021 1.00

+1 358 0.0048 1.00

+1 359 0.0052 0.99

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 57 SOF 1-Ws Sign (Ws) 360 0.0092 0.99

+1 361 0.0073 0.99

+1 362 0.0091 0.99

+1 363 0.0028 1.00

+1 364 0.0000 1.00

+1 365 0.0001 1.00

+1 366 0.0000 1.00

+1 367 0.0000 1.00

+1 368 0.0029 1.00

+1 369 0.0000 1.00

+1 370 0.0000 1.00

+1 371 0.0000 1.00

+1 372 0.0000 1.00

+1 373 0.0000 1.00

+1 374 0.0010 1.00

+1 375 0.0000 1.00

+1 376 0.0000 1.00

+1 377 0.0000 1.00

+1 378 0.0028 1.00

+1 379 0.0000 1.00

+1 380 0.0000 1.00

+1 381 0.0000 1.00

+1 382 0.0000 1.00

+1 383 0.0000 1.00

+1 384 0.0000 1.00

+1 385 0.0000 1.00

+1 386 0.0000 1.00

+1 387 0.0002 1.00

+1 388 0.0000 1.00

+1 389 0.0048 1.00

+1 390 0.0014 1.00

+1 391 0.0029 1.00

+1 392 0.0025 1.00

+1 393 0.0042 1.00

+1 394 0.0059 0.99

+1 395 0.0080 0.99

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 58 SOF 1-Ws Sign (Ws) 396 0.0073 0.99

+1 397 0.0100 0.99

+1 398 0.0071 0.99

+1 399 0.0081 0.99

+1 400 0.0087 0.99

+1 401 0.0137 0.99

+1 402 0.0128 0.99

+1 403 0.0109 0.99

+1 404 0.0093 0.99

+1 405 0.0126 0.99

+1 406 0.0123 0.99

+1 407 0.0148 0.99

+1 408 0.0150 0.98

+1 409 0.0218 0.98

+1 410 0.0194 0.98

+1 411 0.0169 0.98

+1 412 0.0186 0.98

+1 413 0.0122 0.99

+1 414 0.0140 0.99

+1 415 0.0127 0.99

+1 416 0.0154 0.98

+1 417 0.0128 0.99

+1 418 0.0216 0.98

+1 419 0.0169 0.98

+1 420 0.0177 0.98

+1 421 0.0118 0.99

+1 422 0.0168 0.98

+1 423 0.0193 0.98

+1 424 0.0146 0.99

+1 425 0.0214 0.98

+1 426 0.0170 0.98

+1 427 0.0141 0.99

+1 428 0.0066 0.99

+1 429 0.0107 0.99

+1 430 0.0103 0.99

+1 431 0.0117 0.99

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 59 SOF 1-Ws Sign (Ws) 432 0.0091 0.99

+1 433 0.0113 0.99

+1 434 0.0073 0.99

+1 435 0.0060 0.99

+1 436 0.0015 1.00

+1 437 0.0042 1.00

+1 438 0.0030 1.00

+1 439 0.0025 1.00

+1 440 0.0039 1.00

+1 441 0.0030 1.00

+1 442 0.0049 1.00

+1 443 0.0038 1.00

+1 444 0.0006 1.00

+1 445 0.0003 1.00

+1 446 0.0027 1.00

+1 447 0.0019 1.00

+1 448 0.0017 1.00

+1 449 0.0033 1.00

+1 450 0.0048 1.00

+1 451 0.0050 1.00

+1 452 0.0065 0.99

+1 453 0.0031 1.00

+1 454 0.0063 0.99

+1 455 0.0018 1.00

+1 456 0.0050 0.99

+1 457 0.0017 1.00

+1 458 0.0000 1.00

+1 459 0.0065 0.99

+1 460 0.0038 1.00

+1 461 0.0041 1.00

+1 462 0.0009 1.00

+1 463 0.0000 1.00

+1 464 0.0000 1.00

+1 465 0.0027 1.00

+1 466 0.0081 0.99

+1 467 0.0114 0.99

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 60 SOF 1-Ws Sign (Ws) 468 0.0103 0.99

+1 469 0.0130 0.99

+1 470 0.0130 0.99

+1 471 0.0099 0.99

+1 472 0.0110 0.99

+1 473 0.0086 0.99

+1 474 0.0062 0.99

+1 475 0.0161 0.98

+1 476 0.0153 0.98

+1 477 0.0182 0.98

+1 478 0.0187 0.98

+1 479 0.0159 0.98

+1 480 0.0169 0.98

+1 481 0.0121 0.99

+1 482 0.0051 0.99

+1 483 0.0135 0.99

+1 484 0.0131 0.99

+1 485 0.0015 1.00

+1 486 0.0012 1.00

+1 487 0.0000 1.00

+1 488 0.0029 1.00

+1 489 0.0000 1.00

+1 490 0.0000 1.00

+1 491 0.0000 1.00

+1 492 0.0023 1.00

+1 493 0.0000 1.00

+1 494 0.0075 0.99

+1 495 0.0076 0.99

+1 496 0.0091 0.99

+1 497 0.0192 0.98

+1 498 0.0212 0.98

+1 499 0.0229 0.98

+1 500 0.0236 0.98

+1 501 0.0240 0.98

+1 502 0.0484 0.95

+1 503 0.0836 0.92

+1

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 61 SOF 1-Ws Sign (Ws) 504 0.0976 0.90

+1 505 0.0986 0.90

+1 506 0.0950 0.91

+1 507 0.0928 0.91

+1 508 0.0963 0.90

+1 509 0.0992 0.90

+1 510 0.0984 0.90

+1 Number of positive differences (S+)

510 Critical Value 274 Survey Unit Meets the Acceptance Criteria

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 62 ATTACHMENT 4 QUALITY CONTROL ASSESSMENT

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT Sl-011-102 Table 16-3-Survey Unit S1-011-102 QC Assessment Standard Measurement Replicate Activity

+20%

-20%

Activity Acceptable ID Value ID Value (YIN)

A0S 0

0 0

A0SQC 0

y A12 0

0 0

A12QC 0

y A34 0

0 0

A34QC 0

y A40 0

0 0

A40QC 0

y A47 0

0 0

A47QC 0

y A66 159 191 127 A66QC 0

N A76 339 407 271 A76QC 122 N

A95 585 701 468 A95QC 295 N

A97 186 223 149 A97QC 246 N

B20 0

0 0

B20QC 0

y C06 0

0 0

C06QC 0

y C24 0

0 0

C24QC 0

y C42 0

0 0

C42QC 142 N

C56 47 56 38 C56QC 15 N

C67 0

0 0

C67QC 0

y C85 0

0 0

C85QC 0

y C89 0

0 0

C89QC 27 N

C90 0

0 0

C90QC 128 N

D32 1037 1245 830 032QC 802 N

D79 128 154 102 D79QC 157 N

E03 137 165 110 E03QC 51 N

E14 1102 1323 882 E14QC 191 N

E19 4687 5625 3750 El9QC 2434 N

E20 4738 5685 3790 E20QC 3194 N

E24 4765 5718 3812 E24QC 4407 y

Comments/Corrective Actions: The replicate measw-ement results are in acceptable The acceptance criteria for replicate static rneasw-ernents is that the same agreement conclusion is reached for each measw-ement. This is defined as the replicate measw-ement being within 20% of the standard measw-ernent. 1n cases where the replicate measw-ement is not within 20% of the standard measw-ement, but both measw-ements are below the Operational OCGL, there is an acceptable agreement.

63

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 64 ATTACHMENT 5 GRAPHICAL PRESENTATIONS

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 65 Figure 16 Quantile Plot for Gross Gamma Activity

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 66 Figure 16 Histogram for Gross Gamma Activity

~

LACROSSESOLUTIONS

FSS RELEASE RECORD - REVISION 1 CIRCULATING WATER DISCHARGE PIPE SURVEY UNIT S1-011-102 67 Figure 16 Retrospective Power Curve for Survey Unit S1-011-102

~

LACROSSESOLUTIONS Probability that the unrey -nit Passes 1.0 0.8 0.6 0.4 0.2 0.0 1 )%

3)%

50%

,0%

9)% 1 )0% 110%

130%

15 0%

True urve_* Unit Concentration (percent of D GL)