Informs That San Luis Obispo Mothers for Peace (MFP) Portion of Supplement to MFP 741028 Stop Work Order Motion Adds Nothing of Substance.Author Unclear Re Whether Board 741104 Order Covers Supplement
ML20236D192
Person / Time
Site: Diablo Canyon, 05000000
Issue date: 11/22/1974
From: Crane P
PACIFIC GAS & ELECTRIC CO.
To: Bowers E
Atomic Safety and Licensing Board Panel
Shared Package
ML20236A877 List: ... further results
References
FOIA-87-214 OL, NUDOCS 8707300347
Download: ML20236D192 (6)


Text

i L

/

\\

y 7....-

PACIFIC GAS AND E LE C T RIC C O M PANY EG *.7!84 l

7 7 B E ALE S T R E ET. S A N F R ANCISCO. C ALIFO R NI A 9 410 6 = (415 ) 7 81 4 211 i

P R E D E RIC K T. S E A R L S es.a. s ess,

=a anaa'. e.aan m int November 22, 1974

!?iliG!!E*?"

aoN N c.'uoRm;eaey j'y.M[y. *.ht

  • sucian uncan comet o.-l;,g;;;.7,,

f:,t:*,? apt"*"

ws6umu s. muoe a

{ff,.'j*,(.yg*1;'[.***

wi6uau a.4oaws watcotun.runsusn offt;tM:;';;;

enaa Ls s v. yaw osu saw

/

g *!,lj?.g"J{l.j'y **'

';' 7 Q

c:. ;; L :ts~*-

uaLcoLu a u eneLLoe L. s

., 3

  • * **i.' t."t ":

f,f.f}j e a sue a. e n AN s. e a.

[.m.,, -..

H

[((.),Lif,*,,"?. i.

nawnys. Lee 6aata

\\-g

, 3,,

p.'*{ff,t.. ';;t!..,,..

n enaaioa.cLanxs aonw s.esesom

$5)

,w,

/N/

Chairman,,

N,.

Elicabeth S. Bowers, Ecq.

i Atomic Safoty and Liconoing Board Pc,nci U. S. Atomic Energy Commission Washington, D. c. 20545 l

Ron Docketa 50-275-OL 50-323-OL

Dear Mrs. Bowers:

It 10 not clear to me t/nother the Board's. order dated November 4,1974 covers the supplement to.the stop work order motion filed by tho San Luis Obispo Fothers For Peace (MFP) dated October 28, 1974.

j The MFP portion of the supplcmont adds nothing of sub-stance to the original motion.

Whilo we may not accept all the allegations in the attached statement by Dr. Dcvid Chipping, it 1

is difficult to quarrel with his conclucion (par. 6).- that the l

so -called Hocgri fpult zone should be "taken rather seriously".

1 of course, it in being taken seriously, as evidenced by our submittalc to the FSAn, and we expect to consider it on the record during the operating licenso hearing.

In any.ovent, j

Dr. Chipping's statement provides no basis for issuance of a 1

stop work order, nor does it purport to provide any'su,ch bacio.

I In short, the supplement adds nothing to the original motion, which has already been denied.

Very truly yours,

,J1 B707300347 870721

~

Philip' A. Crane, Jr.

PDR FOIA CONN 0RB7-214 PDR an~&

(CIFIC GAS AND ELECTRid COMPANY uim COPY Elizabeth S. Bowers, Esq.

2 November 22, 1974' c-CC w/attachmont:

Elizabeth E.. Apfelberg Richard L. Black, Esq.

Glenn 0,. Bright Willihm P. Cornwell Frederick Einsler John J. Forster Lonnie Valentine Angelo Giunbusso Nathaniel H. Goodrich, Esq.

Dr. William E. Martin Alan S. Rosenthal, Ecq.

Secretary U. S. Atomic Energy Commission Sandra A. Silver Andrew Skaff, Esq.

James R. Yore, Esq.

e if e

ll i.

4

cAttr* N A etsourcf 5 Ao!Ncy toNALD REAc AN, Co a aor

_ m_ m. _

=,

RN!A REC 0EL WATER' QUAllTY CONTROL C0ARD-r.1

~6;G

\\L COAST R.te AEGION wu.,.

.r n (Au vu a.

oldPo. CAutoRNIA 93401' g.

November 13, 1974 g..=,

w-O 6,.

,1 13

(.s.

i

g. -

4 s

Mr. John T. Wells 3'

,.g,. W 1

Pacific Gas & Elcetric Co. -

r -.'

e

  • ~ '

3400 Crow Canyon Road San Ramone, Ca. 94583

\\n f: '

.- s

'I',A t.D.L.,

Dear Sir:

Qc g}, -

On October 11, 1974 the Board adopted Order No. 74-41 and NPDES porzit No. CA0003751' Waste Discharge Requirements for PGLE Diablo Canyon I

Nucicar Power Plant in San Luis Obispo County.

This was an interim permit which expires May 1,1976 and ellows PGLE time to complete all studies i

necessary to implement the provisions of all regulations established pur-j suant to Section 316(b) of the Federal Water Pollution Control Act.

)

q

. In Order No. 74-41 it was stated thdt the monitoring and Isporting

)

programs adopted October 17, 1969 shall remain in effect, but thut tne j

Executive Officer may revise or amend the program for any reason including gathering data on low volume waste sources.

he to the problems encountered in Diablo Cove from startup and testing procedures we have revised the monitoring program to provide informa -

tion which will be used to solve thase problems.

Enclosed is a copy of the revised monitorin6 program for your re-vie..

We would appreciate any comments you have in writi.ag by December 9, 1974. If no response is received by that date we will assume that you j

concur with the program and request that yoti initiate it by January 6,1975 J

Very truly yours, j

KDiNLTH R. J0FTES i

Ibcecutive Officer i

i KRJ:JN/kj Encl.

i 1

1 e

0 O

4m l

e

CALIIDENIA R~!OliAL VATra GALITY CO.'iTROL BOARD w

CEiTRAL COAST RD3 ION Monitorine; Pro rem and Schedule of Technical Reports to be Sui:.itted to Ro ionnl isonrd bv c

Pacific Gar, L Electric Connany - Diablo Canyon Nuc1 car Po.-ter Plant, San Luis Obicno County I.

Records to be maintained concerning plant discharge:

A.

Average daily volume of waste discharge.

Total daily flow during

-pre-operational testing.

B.

Oil content of diccharge from oil removal facilities - intermittent dischargo to be sampled quarterly.

C.

pH of discharge -- daily when chemical cleaning of equipment is in progress. Also pH of intake when back washing.

D.

Temperature of cooling water. intake and discharge -- daily.

E.

Static Bionssay (96 hr' TLa, using species indigenous to receiving l

vater arca) of dit.~harge during pre-startup cleaning of equipment'-

and piping, trier to discharre of matdrials to Diablo Cove. Bio-assays are to be conducted prior to any materials discharged to the receiving water. Accumulation of heavy metals in tissue shall bc conducted on all biccssay testod animals.

This is to be done until it is determined the toxic effects of all materials discharged.

Bioassay on the screen backflush water for the worst possible cases shall also be conducted.

F.

Concentration of radioactivity in the discharge, including the total quantity -- daily.

G.

Concentration of heavy metals in the discharge, including total daily mass emission rates. Water sampics are to be taken during pro-startup, pump testing, start up after maintenance operations and at other times as specified by the staff of the Regional Board.

Water sampics are to be taken at initial discharge and at 2 minute intervalo not to exceed 45 minutes. Precicion of measurement for heavy metal analyses must bc + 1 ppb. *his testing chall continue until the decay rate of corrocion in the 'cystem has been determined.

II.

Records to be maintained concerning receiving waters:

A.

Completo radiological waste monitoring program as deeme'd adequate by the Stato Department of Public Health and relevant to the receiving waters, environment and diceharge.

B.

Ecologieni studico as specified by the Department of Fich and Gamo chall be continued in order to evaluate ' changes of the marino plant and animal distribution and abundance within Diablo Covo.

.. l C.

Ecologien1 studies as specified by the Department of Fish and Gamo shall be conducted in the maring environment outside* of Diablo. Cove, in order to evaluate the ecologica1' conditions.

.. D.

Acrial photographs of the existing kelp beds from Pecho Rock to Point Buchon chall be taken three times per ye'ar, during February, June and October, for a period of at least two years after initintion of operation.

E.

Surface water temperatures 'shall be determined at.two-month intervals from Point Buchon to Pocho Rock for at least two years following the beginning of diceharge.

Isotherms shall be determined in 2 F intervals. Individual surveys shall be conducted consistently during the late mornin6 hours at the same time each day.

F.

Water temperatures chall be measured at one meter intervals from the surface to the bottom at seven stations prescribed by the Department of Fish and Game inside and adjacent to Diablo Cove. Measurements shall be taken in February, June, and October.

Precisica of measure 0

ments chall be within + 0.2 F.

G.

Five 1/2 square meter quadrats in the rocky intertidal zone at loca-tions formerly documented by the Department of Fish and Gam = hall be photographed three times por year for at least two years follow-iig discharge. A 2-1A" color transparency shall be used for this purpose. Photographic schedule will conform to recommendations of the Department of Fish and Game.

H.

pH and dissolved oxygen content of the receiving waters in February,

' June, and October.

Incident li ht measurements shall be taken at three meter intervalc I.

S from the surface to the bottom at 9 stations prescribed by the Department' of Fich and Game. Measurements chall be taken on a monthly basis during times of discharge. Measurement shall be with a photometer cell.

Co11cetion of samplesh III.

l A.

Temperature, oil, dissolved oxygen, and pH camples shall be grab samples.

.i B.

Sampling for radioactivity monitoring shall be approved by the State Department of Public Health Bureau of Radiolo5 cal Health.

i C.

All other campics chall be coliccted in accordance with accepted procedures having approval of the Department of Fich and Game or the staff of thic Regional Board.

IV. Ecports to the Board:

A.

A report cha11b c made to the Board quarterly on that portion of the l

Stato Department of Public !!calth's approved environmental monitorinc

[

b- -- --------

q

.4..'

3 program relating to the marine environment and the dischargo,

.. including daily radiological concentration and total quantity in the discharge.

Reports shall be made to the Board monthly not'later than the 15th B.

dayor the follo'iing month and shall include:

h.. Results of daily volume r. measurements.

4

2. -Results of daily cooling water intake and discharge temperature measurements.

1

3. Results of oil content analyses of dischar'ge from removal facilities.
4. Rer:ults of all bio-ass'ay (06 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> TLm), tests performed.

f I

5. Results of ecological studies as specified in Paragraph II. B.,

j C., E., F., and H., above.

)

6. Copies of photographs as'specified in Paragraph II. G., above.

J

7. The occurrence of any 3ncideni; causing the F el of ramactivity 1

to exceed permissible levels or causing the r lease of other toxic materials in concentrations detrimental to human, plant, bird or fish life shall be reported within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after its -

occurrence, and its cause, effect, and corrective action shall be described in detail in the next regular report submitted to

' the Regional Board.

V.

Review and Evaluation of Monitoring Program, etc.:

Upon receipt of the Company's report at the end of the second year'of plant operation, this Monitoring Program and Seliedule of Technical Reports shall be re-evaluated in consultation with representatives of the Company, State Departments of Fish and Game and Public Health, and will be revised as deemed necessary to assure continued compliance with the Waste Discharge Requirements, e.

e e

6 i

6 I

t e

E e

_ _ -, _ _ - _ - _ _ _. - _. - - - _ _ -. _ _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ - _ _ - - _ - - _ _ _ -.