- __ _ __ _

"p RANCHO SECO UNIT 1 TECHNICAL SPECIFICATIONS Surveillance Standards 4.4.1.2 Local Leakaae Rate Tests 4.4.1.2.1 Scope of Testing The local leak rate shall be measured for each of the following components:

(1) Personnel hatch (2) Emergency hatch (3) Equipment hatch seals (4) Fuel transfer tube seals (5) Fuel transfer tube shroud bellows (6) Reactor Building normal sump drain line* l (7) Reactor coolant pump seal water outlet line (8) Reactor coolant pump seal inlet line (9) Reactor Building equalizing line (10) Deleted (11) Reactor Building spray inlet lines (12) Deleted (13) Electrical penetrations (14) Reactor Building purge inlet line (15) Reactor Building purge outlet line (16) Reactor Building atmosphere sample lines (17) Letdown to purification demineralized line (18) Pressurizer relief tank gas sample line (19) Reactor coolant system vent header (20) Pressurizer relief tank nitrogen supply line (21) Pressurizer sample line (22) Reactor coolant drain tank header (23) Reactor Building hydrogen sample line (24) H2 recombiner penetration (25) CRD cooling water supply (26) Reactor Building nitrogen supply header (27) Demineralized water (28) Service air (29) Core Flood Tank fill and nitrogen supply (30) Core Flood Tank drain and sample (31) Steam Generator drain (32) Auxiliary steam (33) Component cooling water inlet (34) Component cooling water outlet (35) CRD cooling water return

  • The provisions of Specification 4.0.4 are applicable. l Amendment No. II, 97, 101, 175

" 4-17 soo314o413 890306 2 DR ADOCK 0500

-____- _ _ - _ - _ _ ____ ___