MONTHYEARML20217F3351999-10-14014 October 1999 Notification of 991103-04 Southern Nuclear Operating Licensing Workshop in Birmingham,Alabama with Goal of Improving Licensing Interface Between Licensee & NRC ML20217M4281999-10-0808 October 1999 Requests That Attached Request for Addl Info Be Placed in Pdr.Informs That RAI Faxed to J Bailey on 991008 & Will Be Used to Facilitate Discussions During Upcoming Conference Call Between NRC Staff & SNC Staff ML20207E2431999-05-11011 May 1999 Requests That Encl RAI Be Placed in Pdr.Rai Faxed on 990511 to J Bailey of Snoc to Be Used to Facilitate Discussions During Upcoming Conference Call Between NRC & Snoc Staff ML20204B3651999-03-11011 March 1999 Forwards NRC Approved Operator Licensing Exam (Facility Outline & Initial Exam Submittal & as-given Operating Exam) for Tests Administered on 980721 ML20207L7111999-03-11011 March 1999 Informs That Attached Topics Faxed Today to J Bailey of Southern Nuclear Operating Co,Inc for Sole Purpose of Preparing Licensee Personnel for Upcoming Conference Call ML20204C4751999-03-11011 March 1999 Forwards Exam Repts 50-424/98-302 & 50-425/98-302 for Exams Administered on 980721 ML20207H9181999-02-0505 February 1999 Forwards Facility Submitted Outline,Initial Exam Submittal & as Given Operating Exam for Test Administered on 980413-15 at Plant ML20207H9401999-02-0505 February 1999 Forwards Exam Repts 50-424/98-301 & 50-425/98-301 with as Given Written Exam for Tests Administered on 980413-15 IR 05000425/20010871998-09-22022 September 1998 Redirects Info Encl & Previously Considered as Proprietary, Per .W Ltr NSD-NRC-98-5757 Stated That Encl Rept Is No Longer Considered Proprietary.Encls Originally Submitted as Part of File Package 9504250187 ML20236N6301998-04-0101 April 1998 Submits Task Interface Agreement (TIA-97-12) Suppl Evaluation of TS Required Monthly & Refueling Interval Testing of P-4 Interlock for Vogtle Units 1 & 2 ML20198M9691998-01-13013 January 1998 Notification of 980128 Meeting W/Util in Rockville,Md to Discuss Plant TSs Re Reactor Trip Setpoints & Associated Application for License Amend, ML20236N5921997-12-22022 December 1997 Forwards Task Interface Agreement (TIA-97-12) Evaluation of TS Required Monthly & Refueling Interval Testing of P-4 Interlock for Vogtle Units 1 & 2 ML20199G7471997-11-19019 November 1997 Forwards Memo from Hn Berkow to Jr Johnson, Re Task Interface Agreement 97-07 on Instrument Setpoints,To Be Placed in PDR ML20236N5341997-10-29029 October 1997 Forwards Task Interface Agreement (TIA-97-12) Evaluation of Monthly Surveillance Testing of Reactor Trip Bypass Breaker & ITS P-4 Interlock for Vogtle Units 1 & 2 in Response to 970505 Request from Region II ML20199J2931997-09-16016 September 1997 Discusses Region II Request for NRR Position on Util Practice of Establishing Procedures for RTS & ESF Actuation Sys Instrument Setpoints to Be Nominal Values W/Tolerances Beyond TS Max & Min Allowed Values ML20211D8861997-09-16016 September 1997 Forwards SG Tube Insp Results.Results Were Faxed to J Bailey in Preparation for Conference Call ML20236N2571997-08-0707 August 1997 Forwards TIA-97-07,evaluation Re Reactor Trip & Engineered Safety Features Actuation Sys Instrumentation Setpoints for Plant,Units 1 & 2 ML20141E1781997-05-16016 May 1997 Notification of 970522 Meeting W/Util in Rockville,Md to Allow Licensee to Brief NRC Staff on Results of Analyses of Damage to Unit 1 SG That Was Caused by Parts of Failed Guide Tube Pin Assembly on or About 960529 ML20137R4421997-04-0707 April 1997 Requests That Audio Tapes Identified Be Returned in Order to Return to Region II Office.Licensing Proceeding Terminated & Staff Acted on 10CFR2.206 Petition Initially Filed ML20134P0721997-02-21021 February 1997 Notification of 970304-06 Meeting W/Gpc in Waynesboro,Ga to Review Selected Aspects of Licensee 960515 Submittal to NRC Requesting Approval of Amend to Physical Security & Contingency Plan ML20133G1711997-01-10010 January 1997 Notification of 970116 Meeting W/Util in Rockville,Md to Discuss Schedule for Licensee Submittal & Staff Review & Approval of Plans to Install Addl Fuel Racks in Plant Fuel Pools ML20135F5111996-11-29029 November 1996 Informs That Time Provided by NRC Regulation within Which Commission May Act to Review Decision of Board (LBP-96-16) Has Expired.Decision Became Final Agency Action on 961129. W/Certificate of Svc.Served on 961129 ML20205C2841995-09-15015 September 1995 Informs That Lou Will Not Be Able to Attend 950923 Meeting, Due to Attendance in Headquarters with Chairman Steering Committee.He Will Also Be Gone on 950924 to Work on Vogtle Case ML20128G2831995-03-10010 March 1995 Discusses Region II Review of Proposed Ack Ltr for Vogtle Civil Penalty (EA 93-304),informing That L Reyes,Deputy Regional Administrator,Concurred on Document on 950310 ML20128G2671995-03-0909 March 1995 Forwards Proposed Ack/Closeout Ltr After Receipt of Gpc Check for Listed Amount in Vogtle Edg/Inaccurate Info Enforcement Action.Requests Assistance W/Expedition of Region Comments & Concurrence Re Ack/Closeout on Vogtle ML20128F5261995-01-20020 January 1995 Partially Deleted Memo Notifying Commission of Results of Settlement Discussions Initiated by Counsel for Georgia Power Co & Staff Intent to Accept Licensee Proposal to Resolve Matter ML20128G2291994-12-20020 December 1994 Informs That Last Version of Memo to Commission on Proposed Resolution of Enforcement Action in Vogtle Included in Attached File.Hard Copy to Be Provided.W/O Encl ML20128Q0711994-11-15015 November 1994 Forwards Vogtle Coordinating Group Evaluation of Georgia Power Co Response to Notice of Violation & Demands for Info ML20128G1521994-10-28028 October 1994 Discusses Result of OI Analysis of Gpc Response to Enforcement Action Per Conclusions in OI Rept, Case 2-90-020R ML20128G1311994-08-16016 August 1994 Discusses 940816 Telcon W/E Blake Re Vogtle Licensing Proceeding.E Blake Expressed Concern Re Length of Time Projected for NRC Staff Review of Gpc Response to NOV & Proposed Imposition of Civil Penalty for Vogtle ML20128Q0461994-08-15015 August 1994 Responds to 940804 Memo & Informs That Plant Coordinating Group Being Reassembled to Expeditiously Review,Analyze & Formulate Position on Adequacy of Responses by Gpc ML20129F7351994-06-0909 June 1994 Recommends That Issue Concerning Failure to Take Appropriate Action for Calcon Switch Problems Identified Prior to 900320 Be Closed W/O Further Action ML20128F5421994-05-0909 May 1994 Informs That J Lieberman States That All Vogtle Officials Notified & Press Release Scheduled for 940510 Approved.Task Force Recommended to Commission That Gpc Should Be Cited for Unacceptable Inaccuracies in Reporting to NRC Only ML20128F4891994-05-0909 May 1994 Discusses Factors Involved Re Possible Press Misinterpretation of Scheduled Press Release Concerning Vogtle Enforcement Action Against Gpc ML20128F4751994-05-0606 May 1994 Requests That Gpc & Southern Nuclear Operating Co Be Notified Re Attached Vogtle Press Release for 940509 ML20128G4311994-03-31031 March 1994 Partially Deleted Memo Informing That DPR Has Reviewed Regional Enforcement Recommendation,Draft Commission Paper & Demands for Info Re Vogtle Electric Generating Plant ML20129H1911994-03-0808 March 1994 Partially Deleted Memo Informing That on 940223,first Draft of Proposed Enforcement Action for Georgia Power Co Submission of Inaccurate & Incomplete Info on Plant DG Problem,Distributed ML20129H1361994-02-23023 February 1994 Partially Deleted Memo Forwarding Proposed Enforcement Action for Georgia Power Co Submission of Inaccurate & Incomplete Info on Plant DG Problem,For Review,Evaluation & Comment ML20059L3601994-01-31031 January 1994 Notification of 940202 Meeting W/Util in Rockville,Md to Discuss Review of Various Requested Licensing Activities ML20058K7791993-12-0606 December 1993 Forwards Ltr as Result of 931117 order,LBP-93-22 & Informs That Staff Will Answer Questions Recently Filed by Util ML20129F7291993-11-0505 November 1993 Informs How IIT Supporting Documents on Plant Accessed in Nudocs ML20057E2991993-10-0404 October 1993 Forwards Safety Evaluation Accepting Proposed Emergency Action Level Changes in Rev 15 of Plant Emergency Plan ML20129H0341993-09-16016 September 1993 Forwards for Implementation,Charter for Preparation of Enforcement Proposal Associated W/Oi Investigation Case 2-90-020 Re Reporting DG Reliability.Nominated Individuals to Review Info Collected by OI Listed ML20129H0121993-09-10010 September 1993 Summarizes 930908 NRC Meeting in Rockville,Md Re Plans for Reviewing Findings of Ongoing OI Investigation Concerning 930320 EDG Failures.Meeting Attendees Listed ML20056F7981993-08-24024 August 1993 Notification of 930908-09 Meeting W/Util in Rockville,Md to Discuss Status of Current Licensing Issues & Safety Initiatives for Plants ML20129F6481993-08-14014 August 1993 Documents Series of Meetings at Which Concerns Re Issues of Mgt Integrity & Attitude at Plant Presented & Discussed ML20056C1531993-03-17017 March 1993 Transmits Corrected Page Nine of NRC Brief in Response to Licensee Appeal of Licensing Board Order Granting Petition to Intervene, in Matter of Gap Re License Amend Dtd 930316. Encl Corrects Signature Page ML20128G8161993-02-0909 February 1993 Forwards Corrected Certificate of Svc Re License Amend, Changing Date of Svc from 930203 to 930205 ML20127K3851993-01-0606 January 1993 Notification of Significant Meeting on 930114 W/Util at Region II Re Emergency Plan Changes to Incorporate NUMARC Emergency Action Levels ML20126F4161992-12-18018 December 1992 Notification of 930107 Meeting W/Util in Rockville,Md to Discuss Design & Operability of Alternate Min Recirculation Path in Highhead Pressure Safety Injection Sys 1999-05-11
[Table view] Category:MEMORANDUMS-CORRESPONDENCE
MONTHYEARML20217F3351999-10-14014 October 1999 Notification of 991103-04 Southern Nuclear Operating Licensing Workshop in Birmingham,Alabama with Goal of Improving Licensing Interface Between Licensee & NRC ML20217M4281999-10-0808 October 1999 Requests That Attached Request for Addl Info Be Placed in Pdr.Informs That RAI Faxed to J Bailey on 991008 & Will Be Used to Facilitate Discussions During Upcoming Conference Call Between NRC Staff & SNC Staff ML20207E2431999-05-11011 May 1999 Requests That Encl RAI Be Placed in Pdr.Rai Faxed on 990511 to J Bailey of Snoc to Be Used to Facilitate Discussions During Upcoming Conference Call Between NRC & Snoc Staff ML20207L7111999-03-11011 March 1999 Informs That Attached Topics Faxed Today to J Bailey of Southern Nuclear Operating Co,Inc for Sole Purpose of Preparing Licensee Personnel for Upcoming Conference Call ML20204C4751999-03-11011 March 1999 Forwards Exam Repts 50-424/98-302 & 50-425/98-302 for Exams Administered on 980721 ML20204B3651999-03-11011 March 1999 Forwards NRC Approved Operator Licensing Exam (Facility Outline & Initial Exam Submittal & as-given Operating Exam) for Tests Administered on 980721 ML20207H9181999-02-0505 February 1999 Forwards Facility Submitted Outline,Initial Exam Submittal & as Given Operating Exam for Test Administered on 980413-15 at Plant ML20207H9401999-02-0505 February 1999 Forwards Exam Repts 50-424/98-301 & 50-425/98-301 with as Given Written Exam for Tests Administered on 980413-15 IR 05000425/20010871998-09-22022 September 1998 Redirects Info Encl & Previously Considered as Proprietary, Per .W Ltr NSD-NRC-98-5757 Stated That Encl Rept Is No Longer Considered Proprietary.Encls Originally Submitted as Part of File Package 9504250187 ML20236N6301998-04-0101 April 1998 Submits Task Interface Agreement (TIA-97-12) Suppl Evaluation of TS Required Monthly & Refueling Interval Testing of P-4 Interlock for Vogtle Units 1 & 2 ML20198M9691998-01-13013 January 1998 Notification of 980128 Meeting W/Util in Rockville,Md to Discuss Plant TSs Re Reactor Trip Setpoints & Associated Application for License Amend, ML20236N5921997-12-22022 December 1997 Forwards Task Interface Agreement (TIA-97-12) Evaluation of TS Required Monthly & Refueling Interval Testing of P-4 Interlock for Vogtle Units 1 & 2 ML20199G7471997-11-19019 November 1997 Forwards Memo from Hn Berkow to Jr Johnson, Re Task Interface Agreement 97-07 on Instrument Setpoints,To Be Placed in PDR ML20236N5341997-10-29029 October 1997 Forwards Task Interface Agreement (TIA-97-12) Evaluation of Monthly Surveillance Testing of Reactor Trip Bypass Breaker & ITS P-4 Interlock for Vogtle Units 1 & 2 in Response to 970505 Request from Region II ML20211D8861997-09-16016 September 1997 Forwards SG Tube Insp Results.Results Were Faxed to J Bailey in Preparation for Conference Call ML20199J2931997-09-16016 September 1997 Discusses Region II Request for NRR Position on Util Practice of Establishing Procedures for RTS & ESF Actuation Sys Instrument Setpoints to Be Nominal Values W/Tolerances Beyond TS Max & Min Allowed Values ML20236N2571997-08-0707 August 1997 Forwards TIA-97-07,evaluation Re Reactor Trip & Engineered Safety Features Actuation Sys Instrumentation Setpoints for Plant,Units 1 & 2 ML20141E1781997-05-16016 May 1997 Notification of 970522 Meeting W/Util in Rockville,Md to Allow Licensee to Brief NRC Staff on Results of Analyses of Damage to Unit 1 SG That Was Caused by Parts of Failed Guide Tube Pin Assembly on or About 960529 ML20137R4421997-04-0707 April 1997 Requests That Audio Tapes Identified Be Returned in Order to Return to Region II Office.Licensing Proceeding Terminated & Staff Acted on 10CFR2.206 Petition Initially Filed ML20134P0721997-02-21021 February 1997 Notification of 970304-06 Meeting W/Gpc in Waynesboro,Ga to Review Selected Aspects of Licensee 960515 Submittal to NRC Requesting Approval of Amend to Physical Security & Contingency Plan ML20133G1711997-01-10010 January 1997 Notification of 970116 Meeting W/Util in Rockville,Md to Discuss Schedule for Licensee Submittal & Staff Review & Approval of Plans to Install Addl Fuel Racks in Plant Fuel Pools ML20135F5111996-11-29029 November 1996 Informs That Time Provided by NRC Regulation within Which Commission May Act to Review Decision of Board (LBP-96-16) Has Expired.Decision Became Final Agency Action on 961129. W/Certificate of Svc.Served on 961129 ML20134B7891996-06-25025 June 1996 Board Notification 96-005:discussing Issues Which Involve Challenge Whether Southern Nuclear Operating Co,Inc Possesses Requisite Character,Competence & Integrity & Willingness to Abide by Regulatory Requirements ML20134B7501996-06-0505 June 1996 Board Notification 96-003:discussing Secretary of Labor Decision & Remand Order Which Found That Gap Managers Discriminated Against One of Their Employees,M Hobby ML20134B6771995-11-13013 November 1995 Board Notification 95-017:notifies of Contention Challenging Application of Gpc for Amends to Authorize Southern Nuclear to Operate Plant ML20205C2841995-09-15015 September 1995 Informs That Lou Will Not Be Able to Attend 950923 Meeting, Due to Attendance in Headquarters with Chairman Steering Committee.He Will Also Be Gone on 950924 to Work on Vogtle Case ML20128G2831995-03-10010 March 1995 Discusses Region II Review of Proposed Ack Ltr for Vogtle Civil Penalty (EA 93-304),informing That L Reyes,Deputy Regional Administrator,Concurred on Document on 950310 ML20128G2671995-03-0909 March 1995 Forwards Proposed Ack/Closeout Ltr After Receipt of Gpc Check for Listed Amount in Vogtle Edg/Inaccurate Info Enforcement Action.Requests Assistance W/Expedition of Region Comments & Concurrence Re Ack/Closeout on Vogtle ML20128F5261995-01-20020 January 1995 Partially Deleted Memo Notifying Commission of Results of Settlement Discussions Initiated by Counsel for Georgia Power Co & Staff Intent to Accept Licensee Proposal to Resolve Matter ML20128G2291994-12-20020 December 1994 Informs That Last Version of Memo to Commission on Proposed Resolution of Enforcement Action in Vogtle Included in Attached File.Hard Copy to Be Provided.W/O Encl ML20128Q0711994-11-15015 November 1994 Forwards Vogtle Coordinating Group Evaluation of Georgia Power Co Response to Notice of Violation & Demands for Info ML20128G1521994-10-28028 October 1994 Discusses Result of OI Analysis of Gpc Response to Enforcement Action Per Conclusions in OI Rept, Case 2-90-020R ML20128G1311994-08-16016 August 1994 Discusses 940816 Telcon W/E Blake Re Vogtle Licensing Proceeding.E Blake Expressed Concern Re Length of Time Projected for NRC Staff Review of Gpc Response to NOV & Proposed Imposition of Civil Penalty for Vogtle ML20128Q0461994-08-15015 August 1994 Responds to 940804 Memo & Informs That Plant Coordinating Group Being Reassembled to Expeditiously Review,Analyze & Formulate Position on Adequacy of Responses by Gpc ML20129F7351994-06-0909 June 1994 Recommends That Issue Concerning Failure to Take Appropriate Action for Calcon Switch Problems Identified Prior to 900320 Be Closed W/O Further Action ML20128F4891994-05-0909 May 1994 Discusses Factors Involved Re Possible Press Misinterpretation of Scheduled Press Release Concerning Vogtle Enforcement Action Against Gpc ML20128F5421994-05-0909 May 1994 Informs That J Lieberman States That All Vogtle Officials Notified & Press Release Scheduled for 940510 Approved.Task Force Recommended to Commission That Gpc Should Be Cited for Unacceptable Inaccuracies in Reporting to NRC Only ML20128F4751994-05-0606 May 1994 Requests That Gpc & Southern Nuclear Operating Co Be Notified Re Attached Vogtle Press Release for 940509 ML20128G4311994-03-31031 March 1994 Partially Deleted Memo Informing That DPR Has Reviewed Regional Enforcement Recommendation,Draft Commission Paper & Demands for Info Re Vogtle Electric Generating Plant ML20129H1911994-03-0808 March 1994 Partially Deleted Memo Informing That on 940223,first Draft of Proposed Enforcement Action for Georgia Power Co Submission of Inaccurate & Incomplete Info on Plant DG Problem,Distributed ML20129H1361994-02-23023 February 1994 Partially Deleted Memo Forwarding Proposed Enforcement Action for Georgia Power Co Submission of Inaccurate & Incomplete Info on Plant DG Problem,For Review,Evaluation & Comment ML20059L3601994-01-31031 January 1994 Notification of 940202 Meeting W/Util in Rockville,Md to Discuss Review of Various Requested Licensing Activities ML20058K7791993-12-0606 December 1993 Forwards Ltr as Result of 931117 order,LBP-93-22 & Informs That Staff Will Answer Questions Recently Filed by Util ML20059M9191993-11-19019 November 1993 Board Notification 93-023:forwards Region II Allegation Review Summary Rept Re Alleger Concern on Plant Diesel Generators ML20129F7291993-11-0505 November 1993 Informs How IIT Supporting Documents on Plant Accessed in Nudocs ML20057E2991993-10-0404 October 1993 Forwards Safety Evaluation Accepting Proposed Emergency Action Level Changes in Rev 15 of Plant Emergency Plan ML20129H0341993-09-16016 September 1993 Forwards for Implementation,Charter for Preparation of Enforcement Proposal Associated W/Oi Investigation Case 2-90-020 Re Reporting DG Reliability.Nominated Individuals to Review Info Collected by OI Listed ML20129H0121993-09-10010 September 1993 Summarizes 930908 NRC Meeting in Rockville,Md Re Plans for Reviewing Findings of Ongoing OI Investigation Concerning 930320 EDG Failures.Meeting Attendees Listed ML20056F7981993-08-24024 August 1993 Notification of 930908-09 Meeting W/Util in Rockville,Md to Discuss Status of Current Licensing Issues & Safety Initiatives for Plants ML20129F6481993-08-14014 August 1993 Documents Series of Meetings at Which Concerns Re Issues of Mgt Integrity & Attitude at Plant Presented & Discussed 1999-05-11
[Table view] |
Text
-o October 8, 1999
- 3. .
MEMORANDUM TO: Docket File FROM: Ramin R. Assa, Project Manager, Section 1 Original signed by:
Project Directorate 11 Division of Licensing Project Management '
Office of Nuclear Reactor Regulation
SUBJECT:
VOGTLE UNITS 1 AND 2 - PLACEMENT OF A DOCUMENT IN THE PUBLIC DOCUMENT ROOM RELATED TO FIRST 10-YEAR INTERVAL INSERVICE (ISI) REQUESTS FOR RELIEF (TAC NO. MA4356) l Please place the attached Request for Additionallnformation (RAl) in the NRC's Public Document Room.- The attached RAI was faxed, today, to Mr. Jim Bailey of the Southern Nuclear Operating Company, Inc. (SNC). The attachment will be used to facilitate discussions during an upcoming conference call between the NRC and SNC staff. This document does not constitute a formal roquest for information nor does it represent a formal NRC staff position.
. C
$ p Docket No. 50-425 y . a F; 8
Attachment:
As stated
]N 'fn Distribution: E
- PUBLIC' 3 $
PD 111 R/F E r.n 5
DOCUMENT NAME: G:\PDil-1\VOGTLE\95-07PDR wpd To rcceive a copy of this document, indicate in the box C= Copy w/o atta.chment/erciosure E= Copy with attachment / enclosure N = No copy OFFICE - PDil-1/PW h PDil-1/LA h PDil/SC gN( j NAME RAssa:cnb CHawes O/M REmc DATE ld/ '[ /99 [b / f /99 [$ / 7 /99 OFFICIAL RECORD COPY 9910270217 991008 "'
PDR ADOCK 05000424 P PDR
ga 4%g y .p Ft UNITED STATES j ,j
't NUCLEAR REGULATORY COMMISSION WASHINGTON D,c. 20555-4001 o
%, . . . October 8, 1999.
MEMORANDUM'TO: Docket File FROM:- Ramin R. Assa, Project Manager, Section 1 ;
Project Directorate 11 4 l
- Division of Licensing Project Managemerp j Office of Nuclear Reactor Regulation ,
SUBJECT:
- VOGTLE UNIT 2 - PLACEMENT OF A DOCUMENT IN THE PUBLIC ,
DOCUMENT ROOM RELATED TO FIRST 10-YEAR INTF.RVAL INSERVICE (ISI) REQUESTS FOR RELIEF (TAC NO. MA4356) '
I Please place the attached Request for Additio.nal Information (RAl) in the NRC's Public i
Document Room. .The attached RAI was faxed, today, to Mr. Jim Bailey of the Southern Nuclear Operating Company, Inc. (SNC). The attachment will be used to facilitate discussions !
during an upcoming conference call between the NRC and SNC staff. This document does not )
constitute a formal request for information nor does it represent a formal NRC staff position.
Docket No. 50-425 .
Attachment:
As stated
TECHNICAL LETTER REPORT ,
ON FIRST 10-YEAR INTERVAL INSERVICE INSPECTION ]
REQUESTS FOR RELIEF 1 EOR SOUTHERN NUCLEAR OPERATING COMPANY !
VOGTLE ELECTRIC GENERATING PLANT. UNIT 2 I DOCKET NUMBER 50-425 1
- 1. SCOPE l
l By letters dated November 30,1998 (Letters LCV-1279, and LCV-1280), the licensee, Southern Nuclear Operating Company, submitted a proposed alternative from the augmented reactor pressure vessel examination required by 10 CFR 50.55a(g)(6)(ii)(A) and other requests for relief from the requirements of the ASME Code,Section XI, for the Vogtle Electric Generating Plant, Unit 2. The proposed alternative and relief requests are for the first 10-year inservice inspection (ISI) interval. Based on our review, the following additionalinformation is required to complete the evaluation of the subject requests for relief.
l
- 2. INFORMATION REQUIRED 2.? Request for Relief RR-20 (Revision 1)- The Code requires 100% volumetric and surface examinations of the welds identified in the licensee's submittal. The licensee stated that complete examination of these welds is limited by physical limitations due to geometric configuration. The table provided in the licer'see's submittal provides minimalinformation on coverages achieved. Please provide specific description of geometrical constraints or interferences, and drawings or sketches showing the specific configurations of the subject welds to demonstrate the impracticality of meeting the Code examination coverage requirements. This information is needed to support the determination that the subject Code requirements are impractical in accordance with 10 CFR 50 55a(g)(6)(i).
.2.2 ' Request for Relief RR-30 (Part C-B)*- The Code requires 100% volumetric and surface examinations of the welds identified in the licensee's submittal. The licensee stated that complete examination of these welds is limited by physical
l limiiations due to component configuration. The table provided in the licensee's submittal provides minimalinformation on coverages achieved. Please provide specific description of geometrical constraints or interferences, and drawings or
- sketches showing the specific configurations of the subject welds to demonstrate the impracticality of meeting the Code examination coverage requirements. This information is needed to support the determination that the subject Code requirements are impractical in accordance with 10 CFR 50.55a(g)(6)(i).
- j. Additionally, it is unclear whether relief is for volumetric coverage, surface
]
coverage, or both. Provide clarification detailing the specific examination coverages requiring relief.
l 2.3 Request for Relief RR-34 (Part C-F-1)- The Code requires 100% volumetric and surface examinations of the welds identified in the licensee's submittal. The licensee stated that complete exami-nation of these welds is limited by physical limitations due to geometric configuration, and component obstructions. The table provided in the licensee's submittal provides minimal information on coverages achieved. Please provide specific description of geometrical constraints or I
interferences, and drawings or sketches showing the specific configurations of the subject welds to demonstrate the impracticality of meeting the Code examination coverage requirements. This information is needed to support the determination that the subject Code requirements are impracticalin emdance with 10 CFR 50.55a(g)(6)(i). '
2.4 Request for Relief RR In tne " Code Reauirement for Which Relief is l' Reauested" portion of the submittal, the licensee stated that " Relief is re' quested I
from the requirements of IWA-4000 and IWA-7000 of the 1983 Edition with Addenda through Summer 1983 for piping, valves, and fittings 1 inch NPS and smaller." In the " Basis for Relief" portion of the relief the licensee stated that "...
relief is requested from the record keeping requirements for repairs to piping and components 1-inch NPS and smaller."
.4 IWA-4000 ar.d IWA-7000 contain multiple requirements relating to Repair and Replacements, including; Repair Program Requirements, inspection, Materials,
. Welding and Welder Qualification, Pressure Testing, Examinations, Records, etc.
Based upon the multiple requirements listed in IWA-4000 and IWA-7000 it is !
unclear what specific code requirement (s) the licensee is seeking relief from. The request for reliaf as written appears generic in nature and does not clearly identify-
- the specific requirement (s) for which relief is required, i.e., is the licensee seeking l relief from all of IWA 4000 and IWA-7000 or only IWA-4700 concerning records? '
Provide the specific code requirements (include paragraphs and subparagraphs) l I
for which relief is required. .
l l