TENNESSEE VALLEY AUTHORITY WATTS BAR NUCLEAR PLANT EMPLOYEE CONCERNS TASK GROUP OTHER SITES CEG Element

Title:

Environmental Qualification SWEC Concerns:

A02850412010--001 A02851118005-001 Source Document: NRC Letters of April 5, 1985, and November 14,_1985 Report Number:

SWEC-SQN-47 d

/DbY!M Evaluator:

~

Date J. J. Knightly Reviewed By:

(([,

/o-2 # P L, K. R. Gass Date I

Approved By:

te/.ned/ f 6 A.G.Debb8e 6 ate /

8612090786 861120 PDR ADOCK 05000327 P

PDR 2097T 4

Raport SWEG-SQN-47 Environmental Qualification I.

Introduction Nuclear Regulatory Commission (NRC) letters of April 5, 1985 (reference 1) and November 14, 1985 (reference 2) communicated to TVA the NRC's concerns with the TVA environmental qualification (EQ) program at Sequoyah Nuclear Plant (SQN). These concerns were addressed as issues in the Stone & Webster Engineering Corporation (SWEC) systematic analysis, as follows:

A.

A02850412010-001, Unacceptable Status of Environmental Qualification Program at Sequoyah B.

402851118005-001, Denial by NRC of Request for Additional Time to Complete Environmental Qualification of Sequoyah Equipment Information on the background, corrective actions taken, verification methodology and anlysis, completion status, and any pertinent references is included in this report.

II.

Verification of SWEC Issues A.

Background

The date required by NRC for full compliance with 10CFR50.49 environmental qualification requirements was November 30, 1985.

On April 2, 1985, the NRC staff briefed the NRC Commissioners on the status of environmental qualification of equipment at operating plants.

During discussion, Sequoyah was identified as one of the plants with the largest number of items and components remaining to be qualified. The transcript of these remarks was forwarded to TVA by reference 1.

Later in the year, November 14, 1985, the NRC denied a TVA request for extension of time beyond November 30, 1985, to complete Sequoyah's qualification of equipment. This denial was communicated to TVA by reference 2.

The basis for the denial was outlined in a later communication (reference 3).

This basis was primarily SQN's late start and slow progress on its EQ program.

B.

Corrective Actions Taken The Sequoyah Nuclear Performance Plan (reference 4) acknowledges that much of the qualification documentation was not fully auditable and, in some cases, did not demonstrate full qualification. Subsequent to the voluntary shutdown of Sequoyah, TVA established an Equipment Qualification Project (EQP) with the responsibility for development and implementation of the EQ program. This implementation is estimated by Sequoyah to be over 65 percent complete for all required field corrective actions with remaining open items to be closed before plant restart.

EQP has issued all 95 binders to include or reference the documentation necessary to demonstrate the qualification.

t Page 1 of 2

C.

V2rificetion Methodology The SWEC concerns identified for Employee Concerns Task Group (ECTG) verification were stated as follows:

RIMS NUMBER ISSUE RIMS ITEM A02050412010 Discussion of status of Comp-RIMS-OO1 liance with rule on EQ of electrical equipment plants identified for the greatest number of items +

components remaining to be qualified A02851110005 Request for additional time to com-RIMS-OO1 plete environmental qualification of electrical equipment denied by NRC.

Reasons for this NRC action not included in letter ECTG reviewed the NRC documentation on this issue and the EQ Program status and commitments from Sequoyah's Nuclear Performance Plan.

This documentation review formed the basis for this verification activity.

D.

Verification Analysis SQN's EQ program implementation is nearing completion with a limited number of items remaining to be completed prior to plant startup.

Upon completion of remaining field and technical open items, the program for initial qualification will be complete and qualification will be documented in EQ binders.

Standard Practice SQA 173, "Sequoyah Nuclear Plant 10CFR50.49 Environmental Qualification Program," describes the procedures for ensuring that qualification is' maintained as future plant modifications are made.

E.

Completion Status l,

Sequoyah's EQ Program is effectively addressing the NRC concerns.

Following completion of corrective actions, these SWEC issues can be closed.

III. References 1.

Letter from H. L. Thompson, NRC, to H. G. Parris dated April 5, 1985, " Browns Ferry Nuclear Plant, Units 1, 2, and 3; Sequoyah Nuclear Plant, Units 1 and 2" 2.

Letter from S. J. Chilk, NRC, to H. G. Parris dated November 14, 1995 (No subject designated) 3.

Letter and order from S. J. Chilk, NRC, to TVA dated November 20, 1985, "Sequoyah Nuclear Plant, Units 1 and 2" 4.

Tennessee Valley Authority, Nuclear Performance Plan, Sequoyah, Revision dated July 17, 1986.

Page 2 of 2

..-~.-. -. ~.~...O

s i.-

TVA EMPLOYEE CONCERNS REPORT NUMBER: SWEC-SQN-47 SPECIAL PROGRAM

'i

\\'

s REPORT TYPR: Sequoyah Nuclear Plant Element REVISION NUMBER: 0 TITLE: Environmental Qualificatiota REASON FOR REVISION: N/A

\\.

SWEC SUNNARY STATENENT: The iten:s in this report were identified by the Nuclear Regulatory Coassission (NRC) and were included in the Stone & Webster Engineering Corporation (SWEC) systematic analysis. All items evaluated within this report were verified to be adequately addressed. Corrective actions are in progress.

~

PREPARATION s

PREPARED BY:

$kAk IlflY&

w SIGNATURE DATE

~

REVIEWS PEER:

1 W S.

D.

//-/A-8 (.

SIGNATURE DATE TAS:

A$

As ll

.?

SIGNATURE DATE

~

CGICU**ruCES CEG H:

AL g

gj, SRP:b$rn}b11)

M

'/~ff %

/

SIONATURE DATE

[

SIGNATGRE*

' D!TE APPROVED BY:

Mu/0did lH M NN ECSP NANAGER DATE MANAGER OF NUCLEAR POWha DATE CONCURRENCE (FINAL REPORT ONLY),

3

  • SRP Secretary's signature denotes SRP concurrences are.in files.

2242T i

,._,_--...-,,_,,y,

--..____.-e..-_,.--

.-._._._------,_.-_,-.,,__,,__,,#-,y--ry,---


,