Amends 136 & 75 to Licenses DPR-57 & NPF-5,respectively, Providing Closure Time Requirements for Scram Discharge Vol Vent & Drain Valves
ML20214F390
Person / Time
Site: Hatch  
(DPR-57-A-136, NPF-05-A-075, NPF-5-A-75)
Issue date: 05/13/1987
From: Youngblood B
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20214F393 List:
References
TAC-53327, TAC-53328, NUDOCS 8705260058
Download: ML20214F390 (8)


Text

.

s -

./

k UNITED STATES E

NUCLEAR REGULATORY COMMISSION o-

$1

r Eb -

WASHINGTON, D. C. 20555 GEORGIA POWER COMPANY OGLETHORPE POWER CORPORATION MUNICIPAL ELECTRIC AUTHORITY OF GEORGIA c

j i

CITY OF DALTON, GEORGIA DOCKET NO. 50-321 EDWIN I. HATCH NUCLEAR PLANT, UNIT NO. 1 1

AMENDMENT TO FACILITY OPERATING' LICENSE 4

Amendment No. 136

. License No. DPR-57 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment to the Edwin I. Hatch Nuclear Plant, Unit 1 (the facility) Facility Operating License No. DPR-57 fil6d t

by Georgia Power Company, acting for itself, Oglethorpe Power Corporation, Municipal Electric Authority of Georgia, and City of Dalton, Georgia, (the licensee) dated Septer.ber 19, 1983 as supplemented by letters dated December 14, 1983, December 20, 1983, 4

q September 13, 1985 and January 6,1986, complies with the standards and requirements cf the Atomic Energy Act of 1954, as amended (the Act), and the Commi -ion's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations set forth in 10 CFR Chapter I; l

D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the i

public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have I

been satisfied.

8705260058 870513

'i DR ADOCK 05000321 PDR

- -. -... a - -.... -

m.

~

~

g 2--

4 2.' LAccordingly, ths license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment, and

' paragraph.2.C.(2) of Facility Operating License No. DPR-57 is hereby

' amended to read as follows:

(2)

Technical Specifications.

TheTechnical-Specifications'cgngainedinAppendicesAand-B,as revised through Amendment No.

3, are hereby incorporated in the license. The licensee shall' operate. the facility in accordance with

= +

.the Technical. Specifications.

3.'-This license amendment is effective as of its date of issuance and shall i

be implemented within 60 days of issuance.

3 l

FOR~ THE NUCLEAR REGULATORY COP 94ISSION

\\G

~

]

B. J.:Youngblood,. Director r

Project Directorate II-3 j

Division of Reactor Projects-I/II i

Attachment:

Changes to the Technical Specifications s

Date of Issuance: May 13, 1987 i

i 1

& Yy#p& -

dT

Y Y

i PD#rI-3/DRP-I/II PDf!J 3/DRP-I/II OGC-Bethesda

.pBJYoungblood PD#II-3/DRP-I/II LCrocker/mac

. ADUAb m 04/ 3 0/87 04/2 /87 04/

/87 Of//p/87 3.-

__--..,----.,----,--------_----x_--------_s---.--_u-___------_---.-----_-u--

au

--a m --

w

ATTACHMENT TO LICENSE AMENDMENT NO. 136 FACILITY OPERATING LICENSE NO. DPR-57 DOCKET NO. 50-321 Replace the following page of the Appendix A Technical Specificatiens with the enclosed page. The revised page is identified by.amendnent number and contains vertical lines indicating the area of change.

Revised Page 3.3-7a l

l I

I

.-e...,,

n.-.,,,,

.n,-

~=

LIMITING CONDITION FOR OPERATION SURVEILLANCE REQUIR2MENTS 3.3.I Scram Discharge Volume Vent 4.3.1 Scram Discharge Volume Vent and Drain valves and Drain valves During reactor power operation,

1. ' Valve Position Verific' tion a

all scram discharge volume vent and drain valves shall be Each scram discharge volume vent operable. If this specification-and drain valve shall be verified cannot be met, an orderly shut-to~be in tne.open position

  • at down shall be initiated and least once per 31 days.

the reactor-shall be placed in the Hot Shutdown Condition 2.

Valve Testing within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />..

a. Each scram discharge volume.

vent and drain valve shall.

be operated through at least one complete cycle of full travel at least once per 92 days.

b. At least once per 18 months, it shall be verified that the scram discharge volume vent and drain valves:

1.

Close within 45 seconds l

after receipt of a signal for control rods to scram, and 2.

Open when the scram signal'is re et.

  • These valves may be closed intermittently for testing under administrative controls.

3.3-7a

,3 '

Amendment No. 136

.~.

p ae:

[

UNITED STATE 3 E

NUCLEAR REGULATORY COMMISSION a

.L 8..

WASHINGTON, D. C. 20665 4,

GEORGIA POWER COMPANY j

i OGLETHORPE POWER CORPORATION MUNICIPAL ELECTRIC AUTHORITY OF GEORGIA i

i

' CITY OF DALTON, GEORGIA DOCKET NO. 50-366 EDWIN I. HATCH NUCLEAR PLANT, UNIT NO. 2 l

j AMENDMENT TO FACILITY GPERATING LICENSE j

Amendment No. 75 l

License No. NPF-5 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment to the Edwin I. Hatch Nuclear Plant, Unit 2 (the facility) Facility Operating License No. NPF-5 filed by Georgia Power Company, acting for jtself, Oglethorpe Power Corporation, Municipal Electric Authority of Georgia, and City of Dalton, Georgia, (the licensee)' dated September 19, 1983 as supplemented by letters dated December 14, 1983 December 20, 1983, September 13 '1985 and January 6,~1986, complies with the. standards 4

and requirements of the Atomic Energy'Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in confomity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations set forth in 10 CFR Chapter I; i

D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the j

public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 4

of the Comission's regulations and all applicable requirements have i

been satisfied.

l

_..,.._,1

3-

. 2.

Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-5 is hereby amended to read as follows:

(2)

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 75, are hereby incorporated in the license. The licensee sh611 operate the facility in accordance with the Technical-Specifications.

3.

This license amendment is effective as of its date of issuance and shall be implemented within 60 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION B. J. Youngblood, Director Project Directorate II-3 Division of Reactor Projects-I/II

Attachment:

Changes to the Technical Specifications Date of Issuance: lby 13, 1987 I

)Y PD#LI-3/DRP-I/II PD#IJ)/DRP-I/II OG -B thesda PDfII-3/DRP-I/II LCrocker/mac MDddbh p BJYoungblood

a. % n 04/30 /87 04/J /87 0 g(/87-f 47/3 /87 j

4w

+ -

~

ATTACHMENT TO LICENSE AMENDMENT NO. 75 FACILITY OPERATING LICENSE NO. NPF-5 DOCKET NO. 50-366 Replace the following page of the Appendix A Technical Specifications with the enclosed page. The revised page is identified by amendment number and contains vertical lines indicating the area of change.

Revised Page 3/4 1-21 i

i 4

l l

""* ~*

v e-c-v e rw

- ~ _., _.. _. _, _.. _ _, _

x

~

REACTI iTY CONIROL SYSh55 3/4.1.6 SCRAM DISGARGE VOLINE VENT AND DRAIN VALVES LIMITING Q)NDITION FOR OPERATION 3.1.6.1 All scram discharge volume vent and drain valves shall be OPERABLE.

APPLICABILITY: Conditions 1 and 2.

ACTION: With any scram discharge volume vent.or drain valve inoperable, be in at least H7T SETTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

~

j SURVEILIANCE REQUIREMENTS i

4.1.6.1 The scram discharge volume vent and drain valves shall be demonstrated OPERABLE by:

At least once per 31 days verifying each valve to be open.

a.

a b.

At least once per 92 days cycling each valve through at least one complete cycle of travel.

At least once per 18 months, by verifying that the drain and vent c.

i valves:

1.

Close within 60 seconds after receipt of a signal for control rods to scram, and 2.

Open when the scram signal is reset.

i eThese valves may be closed intermittently for testing under administrative controls.