Rev. 14 10/28/86 l

gev.7.h" coe.., meet Gc'/. on 9

p.g p G R 0,'i A T ! O N O N L l

C. n. Nuclear lu

~

W---

_ _-3-pyM MAINTENANCE PROCEDURE MP-111 FLORIDA POWER CORPORATION CRYSTAL RIVER UNIT 3 VALVE PACKING PROCEDURE AND SPECIFICATIONS THIS PROCEDURE ADDRESSES SAFETY RELATED COMPONENTS l

APPROVED BY: Responsible Section Superintendent /

l Supervisor W W.<.v1 A

/(l0 Date l

INTERPRETATION CONTACT: Nuclear Maintenance Superintendent i

0703130261 G7030D PDR ADOCK 05000302 P

PDR t

l-

~:2 7'..~:~.~*

~ ^~~ T ^ -

is

~

1.0 PURPOSE 1.1 This procedure is to identify valves and set forth the neces-sary limits, precautions, and tools to pack these valves.

Procedure Section Packing Removal 7.1 Packing Installation Using Grafoil Loose Ribbon 7.2 Packing Installation Using Braided Packing 7.3 Packing Installation Using Grafoil Pre-Formed Rings 7.4

2.0 REFERENCES

2.1 IMPLEMENTING REFERENCES 2.1.1 CP-115, In-Plant Equipment Clearance and Switching Orders 2.1.2 MP-118, Valve Bonnet Removal and Reinstallation 2.2 DEVELOPMENTAL REFERENCES 2.2.1 Valve Manufacturer's Instructions 2.2.2 Packing Manufacturer's Instructions 3.0 ENCLOSURES Grafoil Ring Packing Valves Grafoil Ribbon Packing Valves Table of Required Ring Pusher Size Sketch Summary Table Split Ring Pusher (typical)

Packing Ring Fixture (typical)

Valve Work Record MP-111 Rev. 14

_J Page 1

- - - r -

.----~ t.

Ir a

Packing Ring Sequence for Valves Grafoil Ribbon Packing Chart 0 Grafoil Pre-formed Rings Chart l14 4.0 LIMITS AND PRECAUTIONS 4.1 Use only clean, oil-free air or Grade A demineralized water to blow packing from stuffing box.

Do not use system pressure.

4.2 Use face shield or other appropriate safety devices when using air, water pressure, or system pressure during the conduct of this procedure.

4.3 Manufacturer's instruction manuals for valves and packing and valve blueprints should be used if needed to prevent damage to the valve.

NOTE:

If it is not clear how to remove or install packing, notify the Nuclear Mechanical / Building Service Super-visor and follow his instructions.

4.4 It is important for both the protection of the packing and the Reactor Coolant System that steps be taken to insure that the packing and tools do not become contaminated with chlorides, grease, body oils, etc.

Always handle Grafoil ribbon and ring packing with rubber gloves.

4.5 Pre-formed Grafoil rings should be used in all valves using Limitorque operators.

MP-111 Rev.1 4 page 2

t

. ;;,y ac.. _

f-5.0 EQUIPMENT AND PFE ONNEL REOUTRF3 TENTS 5.1 Personnel assigned shall be knowledgeable, experienced and qualified to perform the specified tasks as determined by the appropriate supervisor.

5.2 Use only packing certified to contain less than 200 ppm chlorides.

5.3 Rags and bucket to catch spilled water.

5.4 Molykote-G lubricant for gland stud threads.

5.5 Soft wire or other means to hold up the packing gland or other parts out of the way of stuffing box.

5.6 Small pick or other device to clean out old packing.

5.7 Clean, oil-free air or desineralized Grade

'A' water to blow out old packing and_ debris.

5.8 Small, Stainless Steel, Wire Brush 5.9 Portable Light 5.10 Split ring of proper size, if required 5.11 Packing Ring Fixture (if required) 5.12 Feeler Gauges or Wire Gauges 5.13 Knife for cutting packing.

6.0 REOUIRED INITTAL CONDITIONS AND PLANT STATUS 6.1 The equipment to be worked on is to be isolated and removed from service using an approved Operating Procedure and Equip-ment Clearance Order per CP-115, In-Plant Equipment Clearance and Switching Orders.

MP-111 Rev.1 d Page 3

.a..

is o

6.2 Obtain a Radiation Work Permit (RWP).

7.0 PROCEDURE 7.0.1 Ensure o Limits and Precautions of Section 4.0 have been reviewed.

o Equipment and personnel are available per Section 5.0.

o Initial conditions of Section 6.0 have been met.

Completed By Date 7.1 PACKING REMOVAL 7.1.1 Ensure system pressure to the valve has been bled off.

7.1.2 Backseat the valve (if the valve has a backseat).

7.1.3 Remove gland nuts, gland flange, and gland if removable or slide parts up stem and tie with soft wire to make stuffing box accessible.

7.1.4 Remove old packing with best available method.

NOTE: Care should be taken not to score valve stem or stuffing box surfaces.

NOTE: Methods must be approved by the Nuclear Mechanical /

Building Service Supervisor and Health Physics because of potential contamination hazards prior to use.

Mp-111 Rev. 1 d J

Page 4

~~

c, o

7.1.5 If the valve has one and it is to be reused, remove lantern ring or tie to upper section of valve.

NOTE: The lantern ring may be removed and split and/or the face of the lantern ring drilled and tapped.

7.1.6 Remove any additional packing below lantern ring in accordance with Step 7.1.4.

7.1.7 Check exposed area of valve sten and stuffing box for pits, j'

corrosion, burrs, or cracks.

pay particular attention to those l

stems made of 410 stainless steel.

NOTE: A smooth surface free of pits and burrs is essential for optinua packing performance. Any discrepancy must be l13 resolved by the Nuclear Mechanical / Building Service l

Supervisor and/or Nuclear Plant Engineering.

l Completed By Date 7.1.8 Thoroughly clean the stuffing box and adjacent area using Gride

  • A*

demineralized water and an approved cleaning fluid if necessary to remove any boric acid crystals, dirt, or other residue and chlorides.

NOTE: Cleanliness of packing and materials is of maximum luportance.

Dirt, oil, chlorides, and other foreign material degrades Grafoil packing itself and contami-nates the Reactor Coolant System.

Boric acid crystals can cut and score the valve stems and other parts.

Completed By Date Mp-111 Rev. 1 S page 5

,y

. - + -

u._.

c, o

7.2 PACYTNG INSTALYATION USING CRAFOIL LOOSE RIBBON seeeeeeeeeeeeeeeeeeeeeeeeen..................................

CAUTION: Do not pack valves under system pressure without appropriate approval, eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesessessessessenseness...es.

7.2.1 Obtain sufficient supply of certified packing per Enclosures 2 and 4, of proper size and type for valve being packed.

lt2 7.2.2 Fill out the appropriate sections of Enclosure 7.

j NOTE: The valve stuffing bo.?. and valve stem aust be free from all old packing material before packing the valve.

NOTE:

Enclosures 2 and 4, do not contain all plant valves.

l13 The Nuclear Mechanical / Building Service Supervisor will determine the packing method to be used on valves not listed.

7.2.3 An anti-extrusion ring or junk ring as it is normally called will be used prior to inserting any Grafoil ribbon.

NOTE: This anti-extrusion ring (normally braided packing unless otherwise specified by the Nuclear Mechanical /

Building Service Supervisor) will be placed in the very bottom of the packing chamber or stuf fing box, next to and on top and bottom of a lantern ring, at the very top of the packing chamber on top of the ribbon packing.

Mp-111 Rev.1 4 page 6

~

y ir 7.2.4 After the first anti-extrusion ring is inserted into the bottom of the stuffing box, wrap the Grafoil ribbon packing around the valve stem the specified amount of turns or wraps.

The speci-fled amount of turns or wraps may be determined from the chart of Enclosure 9 or sketches of Enclosure 4.

l14 NOTE: Be sure to add on one wrap of zinc or zinc dusted ribbon per Enclosures 2 and 4 in the middle of the first layer of Grafoil ribbon packing.

7.2.5 Af ter the Grafoil ribbon has been properly wrapped around the valve stem, shove the Grafoil ribbon down into the stuffing box and compress the ribbon approximately 50%, by visual check, as indicated on the chart.

NOTE: To achieve this 50% compression of the ribbon, it will 4

be necessary to use a ring pusher (packing pusher) which is just an extension tool that is placed under the gland follower.

NOTE:

It is not necessary to place a zine or zine dusted l

ribbon la each layer of Grafoil ribbon.

As long as one zine or sinc dusted ribbon is placed on each side of the 1

lantern ring, the stem and valve gland will have enough protection against possible deterioration.

I I

L 1

MP-111 Rev.1el Page 7

~.

ir a

nessesseeeeeeennesseeeeeeeeeeeeeeeeeeeeeeeeeneseeeeeeeeeemenen.

CAUTION:

a.

If packing valve under pressure, the following step should not be done.

b.

On instrument-operated valves, sometimes this is not possible.

esseeeeeeeeeeeeeeeeeennesseneesensenes..

....nesesseen.........

7.2.6 Af ter first ring of Grafoil ribbon packing is compressed 50%

and tension is still being applied by the packing gland studs, stroke the valve fully shut and back to full open.

7.2.7 In each successive ring of Grafoil ribbon, the valve stem should be stroked if possible, to provide prelubrication of the valve stem and promotes easier operation of the valve.

7.2.8 Complete the above steps until the valve chamber has been properly packed.

NOTE: An anti-extrusion ring should be on botton and top of

~

the lantern ring, and as the very last piece of packing added just under the gland follower.

Completed By*

Date 7.3 PAGING INSTM1ATION USING BRAIDED PAGING 7.3.1 Obtain sufficient supply of certified packing per Enclosures 2 or 4,

or per direction of the Nuclear Mechanical / Building l14 Service Supervisor for valves not listed in the enclosures.

l MP-111 Rev.1 4 Page 8

s s

a, f=

v 7.3.2 Fill out the appspriate se::tions of Enclosure 7, Page 73.

NOTE: A list of critical valves for the proper size, type, dimensions, etc.

vill be maintained t.y the Nucl. ear Nechanical/ Building Services Supervisor.

7.3.3 Wrap a length of packing around the valve stem and cut to size with knife so the ends butt together and form a single ring.

(Avoid scratching metal surfaces.)

7.3.4 Make as many additional If.ngs of packing as necessary to fill the stuffing box, using the method in Step 7.3.3, or use the first ring as a pattern.

7.3.5 Place the first ring of packing into the stuffing box opening and force it to the bottom of the stufflag box with a packing pusher adapter.

7.3.6 Replace the gland, gland flange, and gland nuts.

7.3.7 Tighten the glend nuts evenly to a torgde of 3S t 5 f t-lbs.,

until the packing is firmly seated, then remove the gland nuts, gland flange, gland, and pusher adapter.

7.3.8 Repeat Steps 7.3.5 through 7.3.7 to seat each additional ring of packing, svitching to a smaller packing adapter as necessary until the gland stuffing box is full.

Stagger the split in accordance with nanufacturer's or by Nuclear Mechanical /

Building Service !Mpervisor instructions.

NOTE: The lantern ring may.t.e split, drilled, and tap.m.d. if desired.

MP-ill Rev. 1d Page 9

Q*

fb h

(....

q.

7.3.9 when stuffing box is full, install the gland, gland flange, and gland nuts, and torque the nuts to a final torque of 35 5

ft-lbs.,

or as recommended by manufacturer's instructions.

Ensure that the packing gland is properly inserted into the stuffing box.

Packing should not be visible and the gland flange should not be bottoned.

Adjust the packing as neces-sary. Check to be sure the gland flange is not cocked.

Valve #

Torque Wrench ID Cal Date Torque Setting Completed By Date T

7.4 PACIING INSTALLATION USIN( ORAFOIL PRE-FORMED RINGS NOTE: Grafoil rings should be used on all valves using Limitorque operators and some other valves.

Check 0, for a list of valves to use Grafoil rings.

7.4.1 Obtain the proper packing ring fixture for the required ring size.

(See appropriate sketch of Enclosure 4.)

If Enclosure 10, does not contain the packing gland inside diameter (I.D. )

or stem outside diameter (0.D.),

measure these and have the l14 Mechanical / Building Service Supervisor generate a Work Request l

to manufacture the proper size ring fixture and add to l 0 through a procedure change.

l MP-111 Rev. 1 4 d

Page 10 l

ts

-e, 7.4.2 Assemble bottom cap, stuffing box, and stem.

Refer to Enclo-sure 6.

l13 7.4.3 Wrap the ribbon packing around the stem as required by the sketch of Enclosure 4.

l13 NOTE: Be sure to include a minimum of one (1) wrap of Zinc or zine dusted ribbon.

7.4.4 Push ribbon packing down into the stuffing box.

i 7.4.5 Install fixture cap cnto the stuffing box, then tap the cap until the cap comes in contact with the face of the stuffing box.

NOTE: Thie will pre-compress the ribbon packing 70% of its required compression.

I 7.4.6 Remove the fixture cap and stem, then slide the formed ring from the stem.

j 7.4.7 Check the ring to assure it is the desired size.

l l

7.4.8 Repeat Steps 7.4.1 thru 7.4.7 until the desired number of rings 1

has been made, and store the finished rings in a clean container until ready for use.

7.4.9 An anti-extrusion ring (junk ring) will be used prior to i

inserting any Grafoil ribbon.

t l

l i

l I

MF-III Rev. 1 4 Page 11 l

c a.ax_.

I c.

NOTE: This anti-extrusion ring (normally braided packing unless otherwise specified by the Nuclear Mechanical / Building Service Supervisor) will be placed in the very bottom of the packing chamber or stuffing box, next to and on top and bottom of a lantern ring, and at the very top of the packing chamber on top of the ribbon packing.

7.4.10 Fill out the appropriate sections of Enclosure 7.

l13 NOTE: On some valves it may be desirable to remove the bonnet, from the valve for repacking.

Reinstall the valve bonnet per MP-118, Valve Bonnet Removal and Reinstallation.

7.4.11 Ring splits must be staggered 45 to 90' from the previous installed ring split.

7.4.12 Rings must be installed in the packing gland by using a ring pusher (Enclosure 3).

j13 NOTE:

Do not attempt to seat more than two (2) packing rings l

l at any one time, f

l 7.4.13 With the split ring pusher (or gland if dimensionally possible) in place, replace the gland flange nuts and uniformly tighten the packing.

MP-111 Rev.1 4 page 12 i

s.

~ c,-

.z ;

tr e.

7.4.14 If lantern rings are required in the stuffing box, be sure they are placed in the proper location (in accordance with the manu-facturer's assembly drawing).

7.4.15 The proper compression of the Grafoil ring packing is a final height of 65 to 75% of the original uncompressed height.

NOTE: Additional rings of packing may be added if after the final compression the gland flange seats to the stuffing box. Packing should not be visible and the gland flange should not be bottomed.

7.4.16 Check to be sure the gland flange is not cocked.

7.4.17 If possible, operate the valve several times through full travel to insure the valve operates freely.

Completed By Date 8.0 POST-MAINTENANCE TESTING AND SYSTEM RESTORATION l

8.1 Equipment is to be returned to service by an approved operating procedure and/or by release of Equipment Clearance Order per CP-115, In-Plant Equipment Clearance and Switching Orders.

8.2 A functional test of the system involved is to be run by operations per approved Operational procedures or Surveillance Procedures during which the valves worked on are to be checked for leakage.

Any signs of leakage are to be reported to the Nuclear Mechanical / Building Service Supervisor.

MP-111 Rev.1 4 Page 13

- =

i

.a

-s I's

~

GRAFOIL RING PACKING VALVES Egg 7;0SURE 1 (Paje 1 of 6)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RING PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED-SIZE CAV-2 1'

Globe Rockwell

,1.286

.746

.747 x 1.286 x 5/16" CAV-137 1/2' Globe Velan

.498 x 1.005 x 1/4" CAV-128 1/2" Globe Velan CAV-553 3/4 Globe conval l14 MUV-2 3*

Stopcheck Velan 1.873 1.121 1.120 x 1.873 x 15/32" MUV-4 4'

Gate Velan 2.133

. 1.371 1.372 x 2.128 x 3/8" MOV-5 1"

Globe Velan

1.510

.876

.875 x 1.503 x 5/16" MUV-6 3"

Stopcheck Velan 1.121 x 1.781 x 5/16" F

1 4"

Gate Velan 1.372 x 2.128 x 3/8" MUV-10 3"

Stopcheck Velan 1.783 1.124 1.121 x 1.781 x 5/16" MUV-14 4'

Gate Velan 11.372 x 2.188 x 3/8" MUV-15 4"

Gate Velan MUV-16 4'

Globe Fisher 1.378

.749

.748 x 1.377 x 5/16" MUV-17 2-1/2" Globe Velan 2.384 1.123 1.125 x 2.380 x 1/2" NUV-19 2'

Stopcheck Velan MUV-20 2'

Stopcheck Velan 2.380 1.123,1.124 MUV-21 2"

Stopcheck Velan 2.382 1.122 I

MUV-22 2'

Stopcheck Velan NUV-28 2-1/2" Gate Velan

't.783 1.120 1.121 x 1.78 x 5/16" i

NUV-29 2-1/2" Gate Velan 1.885 1.122 1.120 x 1.873 x 15/32" PIUV-30 2-1/2" Globe Velan 2.380 1.123 1.125 x 2.380 x 1/2" l

MP-111 Rev. 1 4 Page 14 1

l

._,g.

-:r-v :; 7 r. - _.. y...:,1..y.

f~s 6...20IL RING PACKING VALVES ENCLOSURE 1 (Continued)

(Page 2 of 6)

I VALVE PACXING GLAND STEM DIM.

GRAFOIL RING PACXING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZC MUV-31 2-1/2 " Angle Bailey 1.377

.747

.748 x 1.377 x 5/16" MUV-32 2-1/2" Gate Velan 1.783 1.123 1.121 x 1.781 x 5/16" MUV-33 2-1/2" Gate Vel an 1.777 1.120 MUV-34 2-1/2" Gate Velan 1.776 1.122 MUV-35 2-1/2" Gate Velan 1.783 1.121 MUV-44 2-1/2" Gate Velan 1.783 1.121 MUV-45 1-1/2" Gate Velan 1.254

.725/.7?7

.726 x 1.254 x 1/4" MUV-46 2-1/2" Gate Velan 1.768 1.124 1.122 x 1.764 x 5/15" MUV-47 2-1/2" Gate Velan 1.760 1.120 r

48 2-1/2" Gate Velan 5IUV-49 2-1/2 " Gate Walworth 1.409

.870

.869 x 1.412 x 1/4" MUV-50 1-1/2" Globe Rockwell 1.535

.998

.998 x 1.530 x 5/16" MUV-51 2-1/2" Angle Leslie 1.503

.876

.875 x 1.303 x 5/15" MUV-74 2-1/2" Gate Velan 1.764 1.122 1.122 x 1.764 x 5/16" MUV-121 1-1/2 " Globe Vel an

.498 x 1.005 x 1/4" MUV-129 1/2" Globe Velan

1. 005

.498/.499

.498 x 1.005 x 1/4" MUV-147 2"

Stopcheck Velan 1.125 x 2.380 x 1/2" MUV-153 2"

Stopcheck Velan 1.125 x 2.308 x 1/2" MUV-253 1"

Globe Rockwell

.747 x 1.286 x 5/15" MUV-254 1/2" Control Velan 1.006

.500/.501

.498 x 1.005 x 1/4"

.i MUV-255 1"

Gate Velan 1.008

.564

.564 x 1.008 x 1/4" MUV-264 2"

Globe Velan 2.384 1.127/1.124 1.125 x 2.380 x 1/2" 265 2"

Stopcheck Velan i

l l

MP-111 Rev.1 4 p,g, 13

.s r u s..,... -

I's i,

e ENCLOSURE 1

.Olt RING PACKING VALVES (Page 3 of 6) t (Continued)

VALVE PACKING GLAND STEM DIM.

GRAF0ll RING PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MUV-266 2"

Globe Velan 2.386 1.129 1.125 x 2.386 x 1/2" MUV-257 2"

Stopcheck Velan 1.125 x 2.380 x 1/2" MUV-364 1/2."

Control Vel an 1.005

.497

.498 x 1.005 x 1/4" MUV-365 1/2" Control Velan 1.00 9

.496 MUV-366 1/2" Control Velan 1.006

.498 MUV-367 1/2" Control Velan MUV-368 1"

Globe Vel an 1.50 3

.873

.875 x 1.503 x 5/15" MUV-369 1"

Globe Velan 1.502

.873 MUV-370 1"

Globe Vel an 1.503

.873 P"*-371 1"

Globe Velan 1.504

.874

~

MUV-372 1"

Globe Velan 1.503

.874 MUV-373 1"

Globe Velan 1.503

.874 MUV-374 1"

Globe Velan 1.501

.874 MUV-375 1"

Globe Velan 1.503

.873 MUV-376 1"

Globe Vel an MUV-377 1"

Globe Vel an MUV-378 1"

Globe Vel an 1.504

.874 MUV-379 1"

Globe Vel an RCV-1 1"

Globe Vel an

.875 x 1.503 x 5/16" P"*-3 1/2" Globe Vel an

.498 x 1.005 x 1/4" MP-111 Rev. 1 4 Page 16

. -. ~, ~ _ _ -

. u er " >.

~

f%

-e ENCLOSURE 1 G..

0IL RING PACKING VALVES (Page 4 of 6)

(Ctntinued)

PACKING GLAND STEM Dill.

GRAF0ll RING PACKING VALVE TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE

.498 x 1.005 x 1/4" RCV-4 1/2" Globe Velan RCV-6 1"

Globe Velan 1.507

.874

.875 x 1.503 x 5/16" RCV-17 1"

Globe Velan RCV-18 1"

Globe Velan 1.507

.869 RCV-22 1-1/2" Globe Velan 1.877

.998 1.002 x 1.875 x 15/32"

.875 x 1.503 x 5/16" RCV-25 1"

Globe Velan RCV-27 1-1/2" Globe Vel an 1.876 1.001 1.002 x 1.875 x 15/32" RCV-30 1"

Globe Vel an 1.509

.875

.875 x 1.503 x 5/15" RCV-33 1"

Globe Velan 35 1"

Globe Vel an 1.122 x 1.764 x 5/15" RCV-36 2-1/2" Gate Vel an

.875 x 1.503 x 5/16" RCV-41 1"

Globe Vel an RCV-44 1"

Glove Velan 1.510

.874 RCV-46 1-1/2" Globe Vel an 1.881

.999 1.002 x 1.875 x 15/32"

(

RCV-48 1-1/2" Globe Velan

.624 x 1.155 x 1/4" RCV-54 3/4 "

Globe Velan i

RCV-55 3/4" Globe Velan M

RCV-56 3/4 "

Globe Vel an RCV-57 3/4 "

Globe Vel an

.875 x 1.503 x 5/16" RCV-60 1"

Globe Velan RCV-61 1"

Globe Velan RCV-62 1"

Globe Velan

.' 3 1"

Globe Velan 6

MP-111 Rev.1 d Page 17 l

. p - 4 c(,....

~c Is e

't

.01L RING PACKING VALVES ENCLOSURE 1 (Crntinued)

(Page 5 of 6)

VALVE PACKING GLAND STEM DIM.

GRAF0Il RING PACXING TAG NO.

SIZE TYPE MANUFACTURER I.O. INCHES 0.D. INCHES REQUIRED SIZE RCV-64 1"

Globe Velan

.875 x 1.503 x 5/16" J

RCV-65 1"

Globe Velan 1.505

.874 RCV-66 1"

Globe Vel an RCV-67 1"

Globe Velan RCV-68 1"

GloDe Velan RCV-69 1"

Globe Velan ACV-70 1"

Globe Velan RCV-71 1"

Globe Velan RCV-72 1"

Globe Velan P "" -73 1"

Globe Vel an RCV-74 1"-

Globe Vel an RCV-75 1"

Globe Velan l

l RCV-76 1"

Glove Velan RCV-77 1"

Globe Velan RCV-78 1"

Globe Velan RCV-79 1"

Globe Yelan RCV-80 1"

Globe Velan RCV-81 1"

Globe Velan 1.506

.873 RCV-82 1"

Globe Velan RCV-83 1"

Globe Velan RCV-84 1"

Globe Velan RCV-85 1"

Globe Velan

1. 506

.869 P ' ' ' -86 1"

Globe Velan MP-111 Rev.Id$

Page 18 l

l

~.v

r -

~

... v.-

Is i.

e Gr..

OIL RING PACKING YALVES ENCLOSURE 1 (C:ntinued)

(Page 6 of 6)

VALVE PACKING GLAND STEM DIM.

GRAF0IL RING PACXIrlG TAG NO.

SIZE TYPE MANUFACTURER I..). INCHES 0.D. INCHES REQUIRED SIZE RCV-87 1/2" Globe Velan

.498 x 1.005 x 1/4" RCV-88 1/2" Globe Vel an 1.006

.498 RCV-89 1/2" Globe Velan

1. 00 5

.497/.496 RCV-90 1/2" Globe Vel an RCV-91 1/2" Globe Velan RCV-92 1/2" Globe Velan 1.005

.499/.498 RCV-93 1/2" Globe Velan RCV-94 1/2" Globe Vel an RCV-103 1/2 "

Globe Velan 1.012

.499 R

104 1/2 "

Globe Velan 1.012

.499 RCV-105 3/4 "

Globe Velan

.624 x 1.155 x 1/4" RCV-106 3/4 "

Globe Velan 1.154

.625 RCV-111 3/4 "

Globe Vel an l

RCV-112 3/4 "

Globe Velan 1.155

.625 RCV-113 3/4 "

Globe Velan 1.157

.624 RCV-114 3/4 "

Globe Velan RCV-115 3/4 "

Globe Velan l

RCV-116 3/4 "

Globe Velan RCV-138 3 /4 "

Globe Vel an l

l RCV-140 1"

Globe Velan RCV-141 1"

Globe Velan RCV-149 1"

Control Vel an l

1 l

MP-111 Rev. 1 4 Page 19

....,e..

w...

e s...... -

I's i.

e GRAF01L RIBBON PACKING VALVES ENCLOSURE 2 (Page 1 of 25)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBBON PACKING TAG N0.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE BSV-2 6"

Gate Crane 1.248 x 1.910 x 5/15" BSV-5 4"

Gate Vel an 1.512

.998

.998 x 1.510 x 5/16" BSV-6 4"

Gate Velan BSV-7 6"

Gate Crane 1.248 x 1.910 x 5/15" B SV-9 3"

Stopcheck Velan

.875 x 1.383 x 5/15" BSV-10 3"

Stopcheck Vel an 1.382

.875 BSV-15 3/4 "

Gate Velan

.754

.406

.406 x.754 x 5/15" BSV-35 3/4 "

Gate Velan BSV-44 1"

Gate Vel an P

45 1"

Gate Velan BSV-46 1"

Gate Velan BSV-47 1"

Gate Velan BSV-48 3/4 "

Gate Velan BSV-49 3/4 "

Gate Velan BSV-59 3/4 "

Gate Vel an B SV-60 3/4" Gate Velan l

BSV-67 3"

Stopcheck Velan

.875 x 1.383 x 5/16" l

BSV-68 3"

Stopcheck Vel an B SV-83 3/4 "

Gate Velan

.406 x.754 x 5/16" B SV-84 3/4" Gate Velan B SV-85 1/2 "

Globe B&W l

l BSV-88 8&W P

90 1/2"

. Globe B&W l

i MP-111 Rev.1di Page 20

l f%

i.

e G...

0IL RIBBON PACXING VALVES ENCLOSURE 2 (C:ntinued)

(Page 2 of 25)

VALVE PACXING GLAND STEM DIM.

GRAF0ll RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.0. INCHES REQUIRED SIZE BSV-91 1/2" Globe B&W BSV-94 1/2" Globe B&W BSV-96 1/2" Globe B&W BSV-101 1"

Gate Velan

.406 x.754 x 5/16" BSV-102 1"

' Gate Vel an BSV-103 1"

Gate Velan

.755

.408 SSV-104 1"

Gate Vel an Chy-32 1"

Gate Velan

.406 x.754 x 5/16" CAV-33 1"

Gate Velan CAV-34 1/2" Gate Velan CAY-35 1"

Gate Velan CAV-36 2"

Globe Vel an 1.004

.564

.564 x 1.004 x 5/15" CAV-37 2"

Globe Velan CAV-50 2"

Gate Velan

.626 x 1.003 x 5/16" CAV-51 2"

Gate Velan 1.004

.627 CAV-52 1/2" Gate Velan

.755

.406

.406 x.754 x 5/16" CAV-53 1"

Gate Vel an CAV-55 1"

Gate Vel an CAV-56 1"

Gate Velan C

57 1"

Globe Fisher

.375 x.885 x 5/16" MP-111 Rev. 1 4 Page 21

.2 T=

L /Olt RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 3 of 25)

VALVE PACKING GLAND STEM DIli.

GRAF0Il RIBBON PAC.<I'4G TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE CAV-59 1"

Gate Velan

.406 x.754 x 5/15" CAV-60 1"

Globe Fisher

.375 x.886 x 5/15" CAV-64 2 "-

Gate Velan

.626 x 1.003 x 5/15" CAV-67 3 /4 "

Gate Vel an

.755

.406

.406 x.754 x 5/15" CAV-82 2"

Gate Vel an

.755

.406 CAV-90 3/4 "

Gate Vel an CAV-98 3/4 "

Gate Velan CAV-99 3/4 "

Gate Vel an CAV-100 3/4 "

Gate Velan

.755

.406 r

101 1/2" Gate Velan C AV -102 3/4 "

Gate Vel an CAV-103 3/4 "

Gate Velan CAV-104 3/4 "

Gate Velan

.755

.406 CAV-105 3/4 "

Gate Vel an CAV-106 3/4 "

Gate Vel an CAV-107 3/4 "

Gate Velan CAV-108 3/4 "

Gate Vel an CAV-111 3/4 "

Gate Vel an CAV-113 1"

Gate Velan CAV-118 1"

Gate Velan CAV-119 2"

Gate Velan

.626 x 1.003 x 5/16" CAV-123 1/2" Gate Vel an

.406 x.754 x 5/16" 130 1/2" Gate Vel an 1.005

.498

.498 x 1.005 x 5/16" MP-111 Rev.1 4 Page 22

..~

g. ~..

('r i

G...

0IL RIBBON PACKING VALVES ENCLOSURE 2 (C:ntinued)

(Page 4 of 25)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE CAV-131 1/2" Gate Vel an

.498 x 1.005 x 5/16" CAV-132 1/2" Gate Vel an 1.007

.498 CAV-133 1/2" Gate Velan CAV-251 1/2" Needle Velan 3/8 x CAV-252 3 /8 "

CAV-309 1/2" Velan CAV-315 1/2 "

Velan CAV-323 1/2" Velan CAV-324 1/2" Velan I..

-325 1/2" Velan CAV-326 1/2" Velan CAV-327 1/2" Velan CAV-328 1/2" Velan CAV-329 1/2" Velan CAV-330 1/2" Velan CAV-331 1/2" Velaa l

CAV-332 1/2" Vel an i

CAV-333 1/2" Velan CAV-336 1/2" Velan CAV-337 1/2" Vel an l

i MP-111 Rev.1 dl Page 23

l

.s

.?

,>1 is e

ENCLOSURE 2 Gan/0!L RIBBON PACKING YALVES (Page 5 of 25)

(Continued)

VALVE PACKING GLAND STEM DIM.

GRAF0ll RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE

.564 x 1.004 x 5/15" l CFV-7 2"

Globe Velan

.626 x 1.003 x 5.15" l CFV-8 2"

Gate Velan CFV-9 2"

Gate Velan 1.003

.563 CFV-10 2"

Globe Velan 1.003

.563

.564 x 1.004 x 5/16" CFV-13 1"

Globe Vel an

.884

.503

.503 x.883 x 5/15" CFV-14 1"

Globe Velan

.440 x.753 x 5/15" CFV-21 1"

Gate Velan CFV-22 1"

Gate Vel an

.753

.440 CFV-25 1"

Globe Fisher 1.00 5

.500

.498 x 1.005 x 5/15" I

26 1"

Globe Fisher

.375 x.886 x 5/15" CFV-29 1-1/2" Globe Fisher

.88 6

.375 1

.406 x.754 x 5/16" CFV-30 1/2" Gate Velan CFY-31 1"

Gate Velan

.753

.440

.44C x.753 x 5/16" CFV-32 1/2" Gate Vel an

.755

.406

.406 x.754 x 5/16"

.440 x.753 x 5/15" CFV-33 1"

Gate Velan

.406 x.754 x 5/15" CFV-34 1/2" Gate Velan CFY-35 1"

Gate Velan

.440 x.753 x 5/16" CFV-36 1"

Gate Vel an

.753

.440

.406 x.754 x 5/15" CFV-37 1/2" Gate Velan CFV-38 1"

Globe Vel an

.875 x 1.503 x 5/15" CFV-39 1"

Globe Vel an CFV-40 1"

Gate Velan

.440 x.753 x 5/16" 5

41 1"

Gate Vel an

.753

.440 MP-111 Rev.1 4 Page 24

, - - - --. m -- - -..- 3 : -.;.....,

.,. s....,.,

x...

tr e

o, Gn. 0!L RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 6 of 25)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBBON PAC.<ING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE CFV-42 1"

Globe Fisher

.886

.375

.375 x.886 x 5/16" CFV-43 1"

Gate Velan

.564 x 1.004 x 5/16" CFV-44 1"

Gate Vel an CFV-45 3/4 "

Gate Velan

.406 x.754 x 5/16" CFV-47 3/4 "

Gate Velan CFV-48 3/4 "

Gate Vel an CFV-50 3/4 "

Gate Velan DHV-7 8"

Gate Crane 1.370 x 2.030 x 1/2" DHV-8 8"

Gate Crane 0HV-9 8"

Gate Crane DHV-10 3"

Gate Vel an

.875 x 1.383 x 5/15" 0HV-13 3/4 "

Gate Velan

.406 x.754 x 5/16" DHV-14 10" Globe Crane 3.026 2.125 2.125 x 3.026 x 11/16" i

DHV-15 3/4 "

Gate Vel an

.406 x.754 x 5/15" l

DHV-16 3/4 "

Gate Velan t

j DHV-18 4"

Gate Crane

.998 x 1.530 x 5/16" i

DHV-19 3/4 "

Gate Velan

.406 x.754 x 5/16" DHV-20 3/4 "

Gate Velan DHV-21 14" Gate Chapman 1.747 x 2.565 x 1/2" f

24 3/4 "

Gate Velan

.406 x.754 x 5/16" MP-111 Rev.1 Page 25

f. :.;.,...

,~2.i y : r.. *.-, -->.,j ;

p y ' r:r:yr, q.-

f*

ENCLOSURE 2 G../0lt RIBBON PACKING VALVES (Page 7 of 25)

( Continued)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE OHV-25 10" Globe Crane 2.125 x 3.026 x 11/16" DHV-26 3/4 "

Gate Vel an

.406 x.754 x 5/15" DHV-27 3/4" Gate Vel an DHV-29 1/2" Gate Velan

.755

.406

.406 x.755 x 5/16" 0HV-30 3/4" Gate Velan

.406 x.754 x 5/15" DHV-31 3/4 "

Gate Vel an 1.747 x 2. 565 x 1/2 "

DHV-32 14" Gate Chapman DHV-39 14" Gate Chapman 2.565 1.747 DHV-40 14" Gate Chapman i

46 4"

Gate Crane 1.530 1.000

.998 x 1.530 x 5/16" 0HV-49 2"

Gete Velan 1.003

.627

.626 x 1.003 x 5/15" DHV-50 3/4" Gate Velan

.406 x.754 x 5/15" DHV-51 1"

Gate velan DHV-52 1"

Gate Vel an DHV-53 1"

Gate yel an 0HV-54 1"

Gate Vel an DHV-57 3/4 "

Gate Velan DHV-58 3/4" Gate Velan DHV-59 1/2" Gate Velan DHV-60 3/4 "

Gate Vel an DHV-61 3/4 "

Gate Vel an OHV-62 3/4 "

Gate Velan

.626 x 1.003 x 5/16" f

65 2"

Gate Velan MP-111 Rev. 1 4 Page 26

N

... : g... -

.-r...,.~

.g.. w w;...,

_,2

(%

e ~.

Gn. 01L RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 8 of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0IL RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE DHV-66 2-1/2" Gate Velan 1.121 x 1.781 x 5/15" DHV-67 2-1/2" Gate Velan DHV-68 4"

Gate Crane

.998 x 1.530 x 5/16" DHV-79 3 /4 "

Gate Velan

.754

.406

.406 x.752 x 5/16" OHV-80 3/4 "

Gate Velan DHV-81 3/4 "

Gate Velan

.406 x.754 x 5/15" I

DHV-82 3/4 "

Gate Velan DHV-83 3/4 "

Gate Vel an OHV-84 3/4 "

Gate Velan E

35 3/4 "

Gate Velan i

DHV-86 3/4 "

Gate Velan i

OHV-87 3/4 "

Gate Velan l DHV-83 3/4 "

Gate Velan DHV-89 3/4" Gate Velan DHV-90 3 /4 "

Gate Velan DHV-92 2"

Gate Velan

.626 x 1.003 x 5/15" DHV-94 3/4 "

Globe Velan

.624 x 1.155 x 5/16" DHV-95 3/4 "

Globe Velan DHV-96 3/4 "

Gate Velan

.406 x.754 x 5/15" DHV-97 1"

Gate Velan DHV-98 1"

Gate Vel an DHV-99

[

100 MP-111 Rev. 1 4 Page 27

.;. s.n,

- ~

....e -. :...,.

..n Y%

s GRAF0!L RI8 BON PACKING VALVES ENCLOSURE 2 Continued)

(Page 9 of 10)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.O. INCHES 0.0. INCHES REQUIRED SIZE OHV-101 1/2" GL Velan l14 OHV-102 1/2" GL Velan l

OHV-103 1/2*

GL Velan l

OHV-104 i/2" GL Velan l

LRV-76 1"

GL Rockwell l14 LRV-77 1"

GL Rockwell l

LRV-78 1"

GL Rockwell l

LRV-79 1"

GL Rockwell l

LRV-80 1"

GL Rockwell l

RV-82 1"

GL Rockwell l

LRV-83 1"

GL Rockwell l

LRV-84 1*

GL Rockwell l

LRV-87 3"

GA Borgwarner l

LRV-88 3"

GA Borgwarner l

LRV-89 3"

GA Borgwarner l

LRV-90 3"

GA Borgwarner l

LRV-91 3"

GA Borgwarner l

LRV-92 3"

GA Borgwarner l

LRV-93 3"

GA Borgwarner l

LRV-94 T

GA Borgwarner l

LRV-95 1"

GA Hancock l

LRV-96 1*

GA Hancock l

IV-97 1*

GA Hancock l

l HP-111 Rev 14 Page 28 (Continued on Page 28a)

....,.;,!~

f - ~,..s.

.m is e

e

'9AF0!L RIBBON PACKING VALVES ENCLOSURE 2 Jontinued)

(Page 9a of 10)

LRV-98 3/4" GA Rockwell l14 LRV-99 3/4" GA Rockwell l14 MSV-18 1"

GL Velan MSV-25 6"

CV Fisher MSV-26 6"

CV Fisher MSV 27 6"

GA Chapman MSV-28 6"

GA Chapman MSV-33 6-10" SV Dresser MSV-34 6-10" SV Dresser MSV-35 6-10" SV Dresser

.V-36 6-10" SV Dresser MSV-37 6-10" SV Dresser MSV-38 6-10" SV Dresser i

MSV-39 6-10" SV Dresser i

MSV-40 6-10" SV Dresser MSV-41 6-10*

SV Dresser MSV-42 6-10" SV Dresser MSV-43 6-10" SV Dresser l

l I

Mp-111 Rev. 1d Page 28a

g.

...y., s.,.... + k' -

, m ' :'O '--

' ~ '

Ir Gnnr'0!L RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 10 of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0IL RIBBON PACKING

. TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MSV-44 6-10" SV Dresser M SV-45 6-10" SV Dresser MSV-45 6-10" SV Dresser MSV-47 6-10" SV Dresser MSV-48 6-8" SV Dresser MSV-55 3"

ASC Crane MSV-56 3"

ASC Crane MSV-73 1"

GL Velan MSV-74 1"

GL Velan I

75 1"

GL Velan MSV-76 1"

GL Velan M SV-77 1"

GL Velan MSV-78 1"

GL Vel an MSV-79 1"

GL Velan MSV-80 1"

GL Velan MSV-81 1"

GL Vel an MSV-82 1"

GL Velan MSV-83 1"

GL Velan MSV-84 1"

GL Velan MSV-85 1"

GL Velan MSV-86 1"

GL Velan MSV-87 1"

GL Velan 88 1"

GL Velan MP-111 Rev. I 4 Page 29 1

... :..,,, ;;z::~.

, d

.-2.f.,..-..,c

~,.a. e.- -

f %-

i.

e be../0lt RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 11 of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0ll RIBBON PACKIr4G TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MSV-89 1"

GL Velan MSV-90 1"

GL Velan MSV-92 1"

GL Velan MSV-93 1"

GA Velan MSV-94 1"

GA Vel an MSV-95 1"

GA Velan MSV-96 1"

GA Yel an MSV-114 1-1/2" GL Vel an MSV-115 1-1/2" GL Vel an 1

116 1-1/2 "

GL Velan MSV-117 1-1/2 "

GL Velan MSV-120 1"

GL Velan MSV-121 1"

GL Velan MSV-122 1"

GL Velan MSV-123 1"

GL Vel an MSV-124 1-1/2" GL Velan MSV-125 1-1/2" GL Velan MSV-126 1-1/2 "

GL Velan MSV-127 1-1/2" GL Vel an MSV-128 4"

GL Chapman MSV-130 3"

GL Chapman MSV-131 1-1/2" GL Velan 132 1-1/2 "

GL Velan MP-111 Rev.1 4 Page 30

...a....

., u.

w

.w. u.e

-a cc. : w:a.

f=

G,..e0!L RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 12 of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0Il RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MSV-133 1-1/2" GL Velan MSV-134 1-1/2" GL Velan MSV-135 1-1/2" GL Velan MSV-138 1"

GL Velan MSV-139 1"

GL Velan e MSV-140 1"

GL Velan MSV-141 1"

GL Velan MSV-142 1-1/2" GL Velan MSV-143 1-1/2 " GL Vel an

?

144 1-1/2" GL Velan MSV-145 1-1/2 "

GL Velan MSV-146 4"

GL Chapman MSV-148 3"

GL Chapman MSV-149 3"

GA Chapman MSV-150 3"

GA Chapman MSV-154 1"

GL Vel an MSV-155 1"

GL Velan MSV-156 1"

GL Velan MSV-157 1"

GL Velan l

MSV-159 1"

GL Velan MSV-160 1"

GL Velan MSV-161 1"

GL Velan t

162 1"

GL Velan MP-111 Rev.1 4 Page 31

\\

- --... - _ -. ~. -

7'..

y.-i 4-

~~.

.w.n.

I*

e ENCLOSURE 2 6.

OIL RIBBON PACKING VALVES (Page 13 of 25)

(Continued)

VALVE PACKING GLAND STEM DIM.

GRAF01L RIBBCN PACKIflG TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MSV-163 1"

GL Vel an MSV-164 1"

GL Vel an MSV-165 1"

GL Velan

'MSV-166 1"

GL Vel an MSV-167 1"

GL Velan MSV-168 1"

GL Vel an M SV-169 1"

GL Vel an MSV-170 1"

GL Vel an MSV-171 1"

GL Vel an P

172 1"

GL Velan MSV-173 1"

GL Vel an MSV-174 1"

GL Velan MSV-175 1"

GL Vel an MSV-176 3"

GA Chapman MSV-177 3"

GA Chapnan M SV-184 3"

GL Chapman MSV-185 3"

GL Chapman M SV-188 1"

GL Velan MSV-191 1-1/2" GL Vel an MSV-192 1-1/2" GL Vel an MSV-193 1-1/2" GL Vel an MSV-194 1-1/2" GL Vel an 196 1"

GL Vel an 6

Page 32 MP-111 Rev. 14

w..

T=

Gn.sr'0!L RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 14 of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0ll RIB 80N PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.0. INCHES REQUIRED SIZE MSV-197 1"

GL Vel an MSV-198 1-1/2" GL Velan MSV-199 1-1/2 "

GL Velan MSV-200 1-1/2 "

GL Vel an M SV-297 1"

GA Velan MSV-299 1"

GA Yel an MSV-301 1"

GA Vel an MSV-303 1"

GA Vel an MSV-400 1"

GL Velan 401 1"

GL Vel an M SV-402 1"

GL Velan MSV-403 1"

GL Vel an MSV-404 1"

GL Vel an MSV-405 1"

GL Vel an I

i MSV-406 1"

GL Vel an l

MSV-409 1/2" GL Vel an i

MSV-410 1/2" GL Velan 24x26 MSV-411 x24 Rockwell M SV-412 Rockwell MSV-413 Rockwell i

M SV-414 Rockwell l

Mtv-433 1-1/2" GL Velan i

i elan Mse-435 1-1/2" GL V

l l

MP-111 Rev. 1 4 Page 33

..c...,....

I's i

t OIL RIBBON PACKING YALVES ENCLOSURE 2 (Continued)

(Page 15 of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0IL RIBBON PACXING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MSV-437 1-1/2" GL Vel an MSV-441 1-1/2" GL Velan MSV-442 1-1/2" GL Velan MSV-443 1-1/2 " GL Velan MSV-444 1-1/2" GL Velan MSV-445 1-1/2" GL Vel an MSV-446 1-1/2 " GL Yelan MSV-447 GL Vel an MSV-448 GL Vel an V ~.449 GL Yel an

~

MSV-450 GL Vel an MSV-431 1-1/2 "

GL Vel an MUV-13 2-1/2 " Gate Velan 1.121 x 1.781 x 5/16" MUV-59 6"

Gate Crane 1.248 x 1.910 x 5/16" MUV-63 6"

Gate Crane l

MUV-64 4"

Gate Velan

.998 x 1.510 x 5/15" l

l MUV-66 6"

Gate Crane 1.910 1.248 1.248 x 1.910 x.5/16" MUV-68 6"

Gate Crane i

MSV-70 6"

Gate Crane 1.910 1.247 MSV-165 1"

Globe Velan 1.502

.876

.875 x 1.503 x 5/16" l

' 166 1"

Globe Velan 1.503

.876 V

l MP-111 Rev. 1 4

_]

Page 34 1

.*...s

..~

_.p.,

ts e '.

b. /0!L RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page lo of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0ll RIBBON PAC.<ING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MSV-167 1"

Globe Velan 1.501

.876

.875 x 1.503 x 5/15" MSV-168 1"

Globe Velan 1.505

.875 MUV-174 1"

Gate Vel an

.406 x.754 x 5/16" MUV-175 1"

Gate Vel an MUV-176 1"

Gate Vel an MUV-177 1"

Gate Vel an

.564 x 1.004 x 5/15" HUV-179 1"

Gate Vel an MUV-184 1"

Gate Vel an MUV-185 1"

Gate Vel an 1.007

.561 202 2-1/2" Gate Vel an 1.785 1.120 1.121 x 1.781 x 5/15" MUV-203 2-1/2 " Gate Velan 1.784 1.120 MUV-204 1/2" Globe Vel an

.883

.503

.503 x.883 x 5/15" MUV-206 1"

Globe Vel an

.875 x 1.503 x 5/15" MUV-207 1"

Globe Velan MUV-220 1"

Globe Vel an MUV-221 1"

Globe Vel an MUV-222 1"

Glooe Vel an MUV-223 1"

Globe Vel an MUV-224 1"

Globe Velan MUV-225 1"

Globe Vel an MOV-226 1"

Globe Velan 1.506

.876 MUV-227 1"

Globe Vel an

-228 1"

Globe Vel an MP-111 Rev. 1 4 Page 35

.c h

{g e ~,-

Gn,40ll RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 17"oT 25)

VALVE PACKING GLAND STEM DIM. l GRAF0h. RIBBON PACKIr1G TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQJIRED SIZE MUV-229 1"

Globe Velan

.875 x 1.503 x 5/16" MUV-230 1"

G1obe Velan s

MUV-231 1"

G1obe Velan

-g s

MUV-232 1"

Globe Yelan

/

MUV-233 1"

G1obe Yelan.

[

MUV-234 1"

Globe Velan

1. 50 5

.877 S

MUV-235 1"

Globe Vel an MUV-262 1"

G1ob'e Velan MUV-263 1"

G1obe Velan f

268 3/4 "

Gate Velan N

.406 x.754 x 5/15"-

MUV-269 3/4" Ga te Velan MUV-271 3/4" Gate Velan I

MUV-272 3 /4 "

Gate Vel an MUV-273 3/4?

Gate Velan MUV-274.

3/4 "

Gate Velan

.755

.406 J

MUV-275 3/4 "

Gate Velan MUV-276 1"

Gate Vel an

.564 x 1.004 x 3/15" i

MUV-278 1"

Gate Vel an i

MUV-279 1"

Gate Velan l*

MUV-280 1"

Gate Velan MUV-281 1"

Gate Velan MOV-282 1"

Gate Velan 283 1"

Gate Velan MP-111 Rev.Ih Page. 36

. - - - - -. -. _. - - - _ -....... _ ~. _... -. - -, -. -

y.

" ;17 n ;.

3...,_.;. ;....

ir is s,

i

,G..

0IL RIBBON PACKING VALVES ENCLOSURE 2

/}(Cottinued)

(Page 18 of 25) a :.

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MUV-284 1"

. Gate Velan

1. 007

.561

.564 x 1.004 x 5/15" I~

MUV-285 1"

Gate -

Vel an MUV-285 1 "'

Gate Vel an

.406 x.754 x 5/15" MUV-28%

1" Gate Velan MUV-288 1"

Gate Vel an j

MUV-289 1"

Gate Vel an

.564 x 1.004 x 5/15" l

MUV-290 1",

. Gate

- Vel an MUV-291 1"

Gate Vel an MUV-292 1"

Gate Velan F

295 1"

Gate Vel an MUV-296 1"

Gate Velan

.406 x.754 x 5/15" MUV-297 1"

Gate Velan MUV-302 1"

G a t'e Velan

.564 x 1.004 x 5/15" MUV-303 1"

Gate Velan l

MUV-310 1"

Gate Vel an MUV-322 1"

Gate Velan MUV-323 1"

Gate Vel an MUV-328 1"

Gate Vel an MUV-333 1"

Gate Vel an MUV-334 1"

Gate Velan MUV-335 1"

Gate Velan 1.007

.561 MUV-336 1"

Gate Velan 1.007

.561 F

337 1"

Gate Velan MP-111 Rev. 1 dl Page 37 n

l

. ~. '...

I%

.i Ghar0!L RIBBON PACXING VALVES ENCLOSURE 2 (Continued)

(Page 19 of 25)

VALVE PACXING GLAND STEM DIM.

GRAF0ll RIBBON PAC.<ING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MUV-338 1"

Gate Vel an

.406 x.754 x 5/15" MUV-340 1"

Gate Vel an

.564 x 1.004 x 5/16" MUV-341 1"

Gate Velan MUV-342 1"

Gate Velan MUV-343 1"

Gate Velan MUV-344 1"

Gate Vel an MUV-345 1"

Gate Vel an MUV-346 1"

Gate Vel an

.406 x.754 x 5/15" MUV-347 1"

Gate Vel an

.564 x 1.004 x 5/15" 5' 348 1"

Gate Vel an

.406 x.754 x 5/15" MUV-349 1"

Gate Velan

.564 x 1.004 x 5/15" MUV-350 1"

Gate Velan

.406 x.754 x 5/16" MUV-351 1"

Gate Velan

.564 x 1.004 x 5/15" MUV-354 1"

Gate Velan MUV-358 1"

Gate Velan

.875 x 1.503 x 5/16" MUV-359 1"

Globe Velan MUV-360 1"

Globe Velan MUV-361 1"

Glooe Velan MUV-362 1"

Globe Vel an MUV-363 1"

Globe Velan MUV-380 1"

Globe Velan MUV-381 1"

Globe Vel an t

382 1"

Globe Velan MP-111 Rev. I dl Page 38 i

u.

tr Gr,.-01L RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 20 of 25)

VALVE PACXING GLAND STEM DIM.

GRAF0ll RIBBON PACKING TAG N0.

SIZE TYPE MANUFACTURER I.D. INCHES 0.0. INCHES REQUIRED SIZE MUV-383 1"

Globe Vel an

.875 x 1.503 x 5/16" MUV-384 1"

Globe Vel an MUV-385 1"

Globe Velan MUV-386 1"

Globe Vel an MUV-387 1"

Globe Vel an MUV-388 1"

Globe Vel an MUV-389 1"

Globe Vel an MUV-390 1"

Globe Velan MUV-391 1"

Globe Vel an f

392 1"

Globe Velan MUV-393 1"

Globe Vel an MUV-394 1"

Gate Velan

.564 x 1.004 x 5/16" MUV-395 1"

Gate Velan MUV-396 1"

Gate Velan MUV-397 1"

Globe Velan

.875 x 1.503 x 5/15" MUV-398 1"

Globe Vel an 1.510

.88 0 MUV-399 1"

Globe Velan MUV-400 1"

Globe Vel an MUV-401 1"

Globe Vel an MUV-402 1"

Globe Velan MUV-403 1"

Globe Vel an MUV-404 1"

Globe Velan 7

f 405 1"

Globe Velan MP-111 Rev.1 Al Page 39

- 7.,

?.-.,

Y%

e o,

G.o../0IL RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 21 of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0Il RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MUV-406 1"

Globe Vel an

.875 x 1.503 x 5/15" MUV-407 1"

Globe Velan MUV-408 1"

Globe Vel an MUV-409 1"

Globe Vel an MUV-410 1"

Globe Velan MUV-411 1"

Globe Velan MUV-412 1"

Globe Velan MUV-413 1"

Globe Vel an MUV-414 1"

Globe Vel an t

415 1"

Globe Velan MUV-416 1"

Globe Vel an MUV-418 1"

Globe Vel an MUV-419 1"

Globe Velan MUV-420 1"

Globe Velan MUV-421 1"

Globe Velan 1.006

.500

.498 x 1.005 x 3/16" MUV-431 1"

Gate Vel an

.564 x 1.004 x 5/16" MUV-435 3/4" Globe Velan l

MUV-436 3/4 "

Globe Vel an MUV-437 3/4 "

Globe Vel an MUV-438 3/4 "

Globe Velan i

i MUV-439 3/4" Globe Vel an l

MUV-440 3/4 "

Globe Velan

?

441 3/4" Globe Velan MP-111 Rev. 1 4 Page 40

.,;. 3

=

Gna/0IL RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 22 of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0Il RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MUV-442 3/4" Globe Velan MUV-443 3/4" Globe Velan MUV-444 3/4" Globe Velan MUV-445 3/4 "

Globe Velan MUV-446 3/4 "

Globe Velan MUV-452 MUV-453 MUV-454 MUV-455 I

456 MUV-457 MUV-458 MUV-459 MUV-460 MUV-461 MUV-462 MUV-463 MUV-464 MUV-465 MUV-466 f

a l

l i

MP-111 Rev.1 4 Page 41 I

g..

-f's G..

0IL RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 23 of 25)

VALVE PACKING GLAND STEM DIM.

GRAF0Il RIB 3ON PACXING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE RCV-2 1"

Globe Vel an

.875 x 1.503 x 5/15" RCV-5 1"

Globe Vel an 1.500

.875 RCV-7 1"

Globe Velan 1.503

.876 i

RCV-16 1"

Globe Velan RCV-19 1"

Globe Velan 1.502

.875 RCV-20 1"

Globe Velan RCV-21 1"

Globe Velan 1.503

.875 RCV-23 1-1/2" Globe Velan 1.875 1.002 1.002 x 1.875 x 15/32" RCV-24 Globe Vel an

1. 000

. 50 0

.875 x 1.503 x 5/15" 4

P 26 1"

Globe Velan RCV-28 1-1/2" Globe Vel an 1.002 x 1.875 x 15/32" RCV-29 1"

Globe Velan

.875 x 1.503 x 5/15" RCV-31 1"

Globe Velan RCV-32 1"

Globe Velan RCV-34 1"

Globe Velan RCV-37 1"

Globe Velan RCV-38 1"

Globe Vel an RCV-39 1"

Globe Velan RCV-40 1"

Globe Velan RCV-42 1"

Globe Velan RCV-43 1"

Globe Vel an RCV-45 1"

Globe Velan 1.502

.872 r

<47 1-1/2" Globe

.Velan 1.002 x 1.875 x 15/32" MP-111 Rev. 1 dk Page 42

T=

^

+

ENCLOSURE 2 GRAF01L RIBBON PACKING VALVES (Page 24 of 25)

(Continued)

VALVE PACKING GLAND STEM DIM.

GRAlq1l RIBB0tl PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES RCQUIRED SIZE

~

RCV-49 1-1/2" Globe Vel an 1.002 x 1.875 x 15/32" RCV-50 1"

Globe Vel an

.875 x 1.5+3 x 5/15" RCV-51 3/4" Globe Vel an 1.155

.625

.624 x 1.15b. x 5/15" RCV-52 3 /4 "

Globe Velan RCV-58 3/4" Globe Vel an RCV-59 3/4" Globe Velan RCV-99 3/4" Globe Velan 1.155

.627 RCV-100 3/4 "

Glooe Velan 1.155

.626 RCV-101 3/4" Globe Vel an I

102 3/4" Globe Velan 1.155

.626 RCV-107 1"

Glooe Vel an

.875 x 1.503 x 5/16" RCV-108 1"

Globe Vel an RCV-109 1"

Globe Vel an RCV-110 1"

Globe Vel an RCV-117 3/4" Globe Velan

.624 x 1.155 x 5/16" RCV-118 3/4" Globe Velan RCV-119 3/4" Globe Velan RCV-120 3/4 "

Globe Velan RCV-126 3/4 "

Globe Velan RCV-127 3/4" Globe Velan RCV-128 3/4 "

Globe Velan RCV-129 3/4" Globe Vel an 130 3/4 "

Globe

. Vel an 1.155

.624 MP-111 Rev. I 4 Page 43

~" -

Ir e

o, 6.. 401L RIBBON PACKING VALVES ENCLOSURE 2 (Continued)

(Page 25 of 25)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE RCV-131 3/4 "

Globe Velan 1.157

.624

.624 x 1.155 x 5/15" RCV-132 3 /4" Globe Velan 1.155

.625 RCV-133 1-1/2 " Globe Velan 1.002 x 1.875 x 15/32" RCV-134 1-1/2" Globe Velan RCV-135 1-1/2" Globe Vel an

1. 880 1.005 RCV-136 1-1/2" Globe Velan RCV-137 3/4 "

Globe Vel an 1.155

.627

.624 x 1.155 x 5/15" RCV-139 3/4 "

Globe Velan RCV-142 3/4" Globe Velan 143 1"

Globe Velan

.875 x 1.503 x 5/16" RCV-144 1"

Globe Vel an SFV-85 3"

Gate Vel an 1.380

.876

.875 x 1.383 x 5/15" SFV-87 8"

Gate Crane 2.030 1.370 1.370 x 2.030 x 1/2" SFV-89 8"

Gate Crane 2.030 1.370 WDV-370 3/4 "

Globe Vel an 1.153

.625

.624 x 1.155 x 5/15" WDV-371 3/4" Globe Velan 372 3 /4 "

Globe Velan MP-111 Rev.1 4 Page 44

~.

p

~

ENCLOSURE 3 JVd8 j

a i

l l

Note 1. Split ring pusher into 2 equal parts.

I L

ficfC i

f, i

i Note 2 - Make two sets of ring pushers for each t

i identification no.. one 2" in length and 1

che other one 1" in length.

6 i

i y

. c 5' edes TABI.E OF REQUIRED RI? G PUSilEP. SIZE

-' Jtor *d *

-se r t ',coe Identification Dim.

"A" Dim. "B" Identification Dim. "A" Di=.

"B" No.

I.D.

0.D.

No.

I.D.

O.D.

1

.375

.880 16 1.000 1.530 2

400

.750 17 1 000 1.875 3

440

.750 18 1.120 1.810 4

499 1.000 19 1.120 1.870 5

.500

.880 20 1.120

1. 31 0

.560 1.000 21 1.120 2.050 7

.624 1.150 22 1.2!0

.375 8

.625 1.000 23 1.250 1.900 9

.747 1.280 24 1.370 2.030 10

.7 4d 1.J75 25 1.J70 2.130 11

.870 1.410 26 1.500

_._50 12

.875 1.300 27 1.500 2.235 13

.875 1.380 28 1.625 2.a00 14

.875 1.500 29 1.745 2.5:0 15 1.000 1.500 30 1.750 2.530 31 2.125 3.025 32 2.370 3.410 33 2.500 3.5e0 MP-1H Rev.1.4 Page 45 ao

+.

~

ENCLOSURE 4 (Page 1 of 25)

SKETCH SLHMARY TABLE Sumary table to identify required sketch to make desired packing ring size f rom ribbon packing.

Sketch Packing Packing Packing Sketch Packing Packir.g Packing 4

I.D.

0.D.

'Jidth

.4 I.D.

0.0.

'Jid e n 1

.375

.886 5/16 16 1.248 1.877 5/16 2

406

.754 5/16 17 1.248 1.910 5/*6 3

440

.753 5/16 IS 1.370 2.030 1/2 4

.498 1.005 5/16 19 1.498 2.25e 1/2 5

.503

.883 5/16 20 1.498 2.235 1/2 6

.564 1.004 5/le 21 1.623 2.408 1/2 7

.624 1.155 5/16 22 1.747 2.5o5 1<2 8

.625 1.003 5/16 23 1.750 2.530 1/2 9

.875 1.383 5/16 24 2.125 3.026 lill:

10

.875 1.503 5/16 11

.998 1.510 5/16 12

.998 1.530 5/16 13 1.002 1.875 15/32 14 1.120 1.873 15/32 15 1 121 1.781 5/16 MP-111' Rev.1 4-Page 46

f ','

ENCLOSURE 4 (Pcg2 2 of 25)

SIZE PACKING REQUIRED

c. 3 75' I.D. x O. 88[p 0 D. x 6 [16 Width

~

/[a Wraps Required Use 2

width Grafoil ribbon.

l s,

i Stem 3"

  • Va 9

O* ~$lb.'.,70Q 3 " = %4 y

I f

+ '"#

c. 380- c o E,

l l

F j

/ 4, 1 % 2 Top Cap 3

l llIlo t Y(A

~

f.

.I 1

Io.e7s.[,%$

I i

A

  • }

O B % 4 cool j "3 /g I

.ce21 l

Stuffing Box

'I T

l e

N O.076l [,7d f

~

{

l l

% 1 %,4 i

O* 3 l

V(A Bottom Cap

~

i f

l

..r.,

..-.~.

a :.

.g '-

r l '%

e ENCLOSURE 4 (Pega 3 of 25)

SIZE PACKING REQUIRED O. 40(p l.D. x O,764 0.D. x S//(o Midth

//

Wraps Required Use YA width Grafoil ribbon.

a, Stem e

f "! V(s4-I

?

f 0 4C(s *Co*

. con 3"E 6 I

'l 4.cci l l

-Yl'l

~

5 Top Cap i

/ 4*,i b, e

l l

7As 1 %

[

i 1

o.7so

  • 0*

. co s 1

i i

e i

A

! O. 764!,*$* i l"t /g I

l l

Stuffing Box l

l l

T p

l i

I i

0,7

,yp

~

l

~l J

Li_i Mc 1 v<,4 E

i l'$ N4 o.4 t o'o"o'o -

Bottom Cap

.::rt,*.i.:p's'

~'-

?

-^':

.>,e I"

ENCLOSURE 4 Pcg2 4 of 25)

SIZE PACKING REOUIRED C.410 I.D. x 0,75 3 0.D. x No Width.

/C Wraps Required Use YJ?.

width Grafoil ribbon.

l o

i Stem 3": Q l

l o

--l H o. 44o + 0

.co%

1 0 2 V44 cn I

e o.45c~*#**%l I

A e

W

?

Top Cap 3

i c-g l

F 7 4"f f l (

b& 2 VG4 l

t l

',7ho +o

o

.cos l

l 6

A I

I Stutfins Box

!O 76NNEl

/ ~f /e1 i

e f

l I

E o.7solQ

~

- i 1

vc1 v +

=

^

a o,y,-ooo?

+. acc f

l "t 'f 4 Bottom Cap 4

'N e.

'..'i..s a.t,,,....-.~..

_.4 j;~

~

{'g.

ENCLOSURE 4 (Page 5 of 25)

SIZE PACKING REQUIRED O 490 I.D. x

/. CO f o,0, x f44 Width

/(.o Wraps Required Use ba "

width Grafoil ribbon.

2,

8 Stem l

.32 L i

,r I

0 460

.#co2 3"

S o.Sog *coe$ l 4

4 e

i p

p o

Top Cap n

s I

f I'4 L E4 l,!

4

%'t b l

e

- l t

/.000*"*g

.oc i

i A

I l

j Stuffing Box

!/.006[."h ie. 17 4

~

j' 7

t l

E i

l O D !, &

l<

l l

[

h,

,l A

f.

4 g

I a

i

,w-Y4 Bottom Cap O50s.Y l

6

~

1 7

,, ), -<. q :p... ~ ~ /

..e-

,t

[4 a

ENCLOSURE 4 (Page 6 of 25)

SIZE PACKING REQUIRED O, 5o3 I.o. x o.683 o.o. x 6//s "

Width

/A Wraps Required Use YG width Grafoil ribbon.

?

I dI i

Stem 3 ".t Q,4 4

b O. S o 3 f. o cos 3"

%,4 O

g Top Cap 1 % t t.+

2 l. lI r

l l 7//(, t hc4 g

I t

O.St3O+'*el

.cos i

I 8

A i

i Stuffing Box I O. 8S M* cst

/ "3 g I

l l

c E

I

o. eso.T-I

~

1 l

\\

W "s Vu 7

m Bottom Cap O 6/CI

~

c'

~

,7 ENCLOSURE 4 (P:_g; 7 ef 25)

SIZE PACKING REQUIRED O. 6M I.D. x /. COM O.D. x

@/(p Width

/4 Wraps Required Use VC. "

width Grafo11 ribbon.

I n

i Stem 3 "2 O I

Y d8 h C. 24 ^ 00-2 l

3"r l

0

-* ""l l l

A o

l W

i 0.570 *C#0 Top Cap g

g p

[3M,' '# f 5

l 4

G4 NM l

7//4

_l t

looo +

'o l

-.cos-1 I

A l

I Stuffing Box

!/ cod +.oso

/ "I /g e91 3

l I

e

?

i e

I I

e 4 000

./, co9.oosi l

~l

[

l--[-

V4 "

  • Vco4 l

0 570 oco i"N l

l Eco4

~-

Bottom Cap l

<r

.~.-

~

i....'.,.e.-

l_

I%

ENCLOSURE 4 (Pzgo 8 of 25)

SIZE PACKING REQUIRED

~

N/ cg O. 0 M r.o. x /. / s 5 o.o. x w1atn

/7 Wraps Required

  1. /2 width Grafoil ribbon.

Use 2,

i Stem b "i '/cs4 I

Y h O. G M _# jo.2 a ".+ w

_i a

l

'l g

e l

l

' O-c e 'l Top Cap F

f g,, t l>1 h144.,

- I t

I

/./Sh_+."il

.e.

I f

l T

Stuffing Box I /. /66_"$',fi

i

/ ".1 Vgg.

J I

I e

E

/. tGo.l.0 l

l

[

i

!. __j r# ~ w.

I

/ M b4 O. CM,.',,*,#

G 1

~

Bottom Cap I

,. f

.1.~~...

Is ENCLOSURE 4 (Page 9 of 25)

SIZE PACKING REOUIRED O 62T I.D. x /, ao ~3 0.D. x M/c, Width

/1 Wraps Required Use

//2., "

width Grafoil ribbon.

t n

i Stem d "! /u 4 i

l v

O.(o?5*+**oo

-o 2

L S's b g

l l

E o.(,30+oi.j i

i g

Top Cap

- oo i

I E

/ %,

V< +

l!!

7S 1 ks+ -

l I.

I i

f z

l,00$ *.*cosl 00 I

8 A

!_/. @ 3 $,,.J 73y 1

Stuffing Box 2

c I

I t

i e

l 000 -,oor!

[

' l I

7 c.*

[.. __j V4 " I % 4 ' '

I

/ 9 V6f Bottom Cap O,(,3o i

s D

,-. 7.

. v..

f4 e

a, ENCLOSURE 4 (Page 10 of 25)

SIZE PACKING REQUIRED O.B76 I.D. x 1.383 0.D. x D//(p Width

/[o Wraps Required Use Va

width Grafoil ribbon.

b>

1 Stem 3 "t N+

l d

h o 875 + c#

.o-L 3 *l E4 s

i

=

e O.86SWl C'

1W 5

Top Cap

- ow,

l ptu g(,+

se.#

l p

l l

1s > nr i

i t

/. 37,5""ok

. cos i

I l

1 4

A

/*Ml3-)

Stuffing Box

/ "r g,4 i

i e

E

/,375 #1G

~

~l

[

~

~

n..l...,n y4 + % +

=

o.se s_ @

f

/ "r b noteom Cap N e_m y,

)

' T' i.a-y-

.j 3

f's

, g ENCLOSURE 4 (Page 11 of 25) o SIZE PACKING REQUIRED O.B76 I.D. x /,503 0.D. x Yno "

Width 20 Wraps Required Use b) "

width Grafoil ribbon.

l l

s, l

Sten 3 " t Vcs )

c i

f y

O 0 1 5 ??z 3 t '/G4

_l l

'I s

l :

I a

o.e30$*%o w

Top Cap C*

g p

j

'j y

, i i

I l

p;Jty34 I

l l

}

I.49 o t.ecsl I

i i

A I

I Stuffing Box

! _ / 6 9 3 * ***'r)

/ "2 '/c,4 j'

t l

I i

e g

cc:

Q 00 %

~

I f

h c.

l l

l

'/4 " 2 V4 4 2

4. e.c f

/ "I %.4 Bottom Cap O 6 M oso' l

4 c

J

3,j,.c-

. 2 'X. -,. -

.+c.

I'\\

ENCLOSURE 4 (Fige 12 of 25)

SIZE PACKINO REQUIRED o.99 8 1.D. x l 6/o

_ 0.D. x k

Width

/6 Wraps Required

'/g "

width Grafoil ribbon.

Use L

l Stem

.3"r %

I y

b

  • h h.* lo 2,

3"2 '44 c

3 I

e

/.o/o d %o l,'W 6

a e

2 Top Cap

-C l

[

f

/,

/ s, +, 4 4 l j, l

% "r 4' 4 g

l l

}

Soo * **s* l

.o.

I i

4 A

I l

Stuffing Box 8/ 6/O-Y-

/ "3 k p q

l l

e E

c:

/.Soo 2.%

l

~I

[

~

l l

l V4 i '/4 $

k 4.oor f

/ "2 '4y I'*#O l

Bottom Cap

-coo l

d 9

~ Y,r...-

.v s s-

,,,;...,. 3..

~

{%

9 %

ENCLOSURE 4 (Page 13 of 25)

SIZE PACKING REQUIRED O.998 I.D. x

/.53o 0.D. x 6A s "

Width

/7 Wraps Required Y

width Grafoil ribbon.

Use 2

a, Stem 3"3 Z4 e

0 96fC" c.o S ~ e %#

e e

a E

toor %co, w

Top Cap I

f

/ C, Pos t

l l

74 02 Ya +

e J

t

=

/.5,s ~....J I

I i

i A

Stutting Box

l. 6 l ** '

j.*, g 4

c E

f,625.ToTr i

t

=

[_lj Vv e M,4

[

Gf S#08 Bottom Cap g

4

,t -

- v. :. ;

.s _.,.. ; r,. ?.. -

fs e %

ENCLOSURE 4 (Page 14 of 25)

SIZE PACKING REQUIRED

/,00 1 I.D. x

/.076 0.D. x 32 Width M

Wraps Required Use 4

width Grafoil ribbon.

o I

Stem 3"1 %4 l

I f

/, 002.

og 0 " ? VG 4-e, a

o

.l l

c' a

l p

y" Top Cap c

l '

l l l O. 63'l. t.CCS,

l_

l

_l j

l 13f +ow I

. n-I e

i 1

A

!].6LD1.$* ll 1

I.2 60 *.CC5 Stuffing Box 3

l l

I e

a

/. 670 I'#c' !

=

"j A

2

!. _....]

4"2 %

f I "2 b f,, s. ~.c_

4 Botton Can coo l

4

71-x,

' st, g'~

...,e s:.

a.

., g. -

.n w..~.

..a.

>=

(r-e ENCLOSURE 4 (Page 15 of 25)

SIZE PACKING REOUIR_ED_

A /20 I.D. x

/,873 o.o. x M/32 Width Md Wraps Required Use M4 "

width Grafoil ribbon.

s, i

Stem l

3 1 Vs 4 e

i o

S,'

{'- I. I102,*la*1 3"

K4 4..g l i

a a

Top Cap

- o c o*

2 1

I 't,iE04 l :

l 0 6'3'.2.r.oes I

i a

1.870+.002l I,.000 I

I

+.002l 11 i

  • .873..000 Stuf fing Box

=>

l.26 t.ccc i

I g

e l

E

+.002 J.870_

.000!

l

'I

[

3

!. _....]

M 't Pu f

GI

!U.~

8 Eatton Cip t.

,.,.. I f., ;,.

^'~.

. & +.-.. + ';

~f\\

ENCLOSURE 4 (P2g2 16 of 25)

SIZE PACKING REQUIRED

/, /Q, /

1.D. x

/.78/

0.D. x

/[G Width

,Q /

Wraps Required Use N2 vidth Grafoil ribbon.

s, I

Sten l

5^2 Pc4 9f d

b - !.rx.'?%.

I 3 ** g if

-e

--l.!So* 4* ;l I

A 2

k-l j Sgek - 44 Top Cap

-o#

l

)

& 8-

] l 7[(e D 44

/

o

_l j

/.? 7.c.g 1

I I

A i

I I

Stuffing Box L/ 7dl* $

/ '} /g

/

4 I

l f

C b

E l.7%Cc1

~

l

~i

[

=

!.....]

!4 t Fa s

f

/ "2 D

/. / 3o+m..I..,.

noteen ca:,

l

.m.

g, A,...

I

i.r'

,.J'

..s

.m a

t s.,

ir e i ENCLOSURE 4 (Page 17 of 25)

SIZE PACKING REQUIRED k"

Width

/. M O I.D. x

/, 6 7 7 0.D. x do Wraps Required Use Y

width Grafoil ribbon.

S I

a, Stem 3 "t Yc.,4 i

I i

y H

H /. '246 2 g f

3"* %

Q 7

o l

i L

1 I. ass Qc w

-5 Top Cap p

3 l l M6

'44 g

l

- I j

[. 670 *#*

.co 1

4 A

1[ OM $.hl j"f p 4 T

Stuffing Box i

I l

t e

t c:

,l. 07;0.eed

~

i

~I i

L_ _j ri m t

cui f

l " 4 /e4 I

l."L55 +,,% :

I

~

Botton Cap i

.n..

,.. :.,.. ; ;+.~ ;r r.-~

-L.....

. r --..wo

<<.-~

f=

e

  • ENCLOSURE 4 (Page 18 of 25)

SIZE PACKING REQUIRED f.746 I.D. x l.9l0 0.D. x 34 g

Width 21 Wraps Required Y.

width Grafoil ribbon.

Use G

,8 a

i i

Stem 3t kg 1

v k

f i. D A b **o*c*o*

3~ t Y -

G4 n

e Top Cap p

3 a

d AbG4 p

i I

j U

1sw:.:.a i

l i

i A

I I

Stuffing Box

!._ I 4 io 1*dSL l " i /g I

y 1

f l

C i

c:

_f.9cci%y

[

\\

\\

y+ wa

=

i

. - ~ ~

f f.i o

4.004 llC Bottom Cap

/* 156 Tc7

~

e 0

I

,L p

.w,,....

l's e

ENCLOSURE 4 s

e (Page 19 of 25)

SIZE PACKING

  • REQUIRED

(, MO I.D. x 2,030 0.D. x VG Width 2.1 Wraps Rcquired Use 3/4. "

wid:h Grafoil ribbon.

i

-sm..

-2 e

db I

i Stem 1 !,

I 3"i Q4 r

N s

(

--d.

h /. 3 yo 4 **

. oca.

l$ "

b g

-l

'l e

n

/,376 # #hl i' l

[

't n

W Top Cap p

l 4 f pgq l

l A" i VG4 g i

o 1

Ml 1.0 0.cos I-j i

i i

l A

I l

1 1

Stuffing Ecx 9-030i.#$%

/ P 1,':;i 9

L l

t 8

C

>o Cf. -

3.o2c'ic%

~

~

l I

[

9 m

[_f;j I

W"i'4+

=

f l "1 '/44

+. oar oso

  • Bottom Cap l

4 e

J

. &.m 6.-l, r~ - '.~

.,'w..,e..--

.~

{%

' ' ~., -

=,

ENCLOSURE 4 (Page 20 of 25) 2-SIZE PACKING REQUIRED

/. N8 I.D. x 2.266 0.D. x a

Width M4 Wraps Required Use

/4 width Grafoil ribbon.

t 4,

Stem 8

3":%4

'/

~,

if dl

[~- /. </18 *c*oo*-

l' 3 " ? '/Sf Lo

l. SOS ~ R l i

I e

p op Top Cap

-om I

g p

/

1 I

e4 3"$ Y64,

l e

p I

_l j

j.

Q,.R& 4 oeA

.cos s

I I

A I

Stuffing Box

!. 2. 2 % I. (e t.

/g"4 l

4-l p

7 I

E e

,2,250 f.o2 l

I

[

=

l l

ya~ yc4 7

r a

c.

' a.

f

/"

/

Botto::: Cap

/ 66 +- oo.c '

i l

<r 9

I 1

, r.., f,.. -

~"~

e.-

Ir ENCLOSURE 4 e i (Page 21 of 25)

SIZE PACKING REQUIRED

/.498 I. D.

y. 9. '2 6 f >

0.D. x A

Width 26~

Wraps Required Use 3/4 width Grafoil ribbon.

t r

l t,

I Stem 3$ 44 1

I l

f d

h-1.49e1 ;'ll 3 "e %

e o

/. Sos _Y,l 1

m l

E i

1---

TOP Cap p

f7 Yfo'f 9

)

1

=

4 2.2eo <~d

.o l

i l

l I

i A

12.. 2 M_*,),f-l

~

7p aj //g Stuffing Box 1

p I

l E

.:2.2eoim I

I I*

il

/4" d /O

~

I w.1 I

/

3 5

.o.,f l 7 a4 7~ 64 s

l-Bottom C.ap

/ 60 octfl l

l l

4 l

i

g;.7 rw ENCLOSURE 4 e

(Pega 22 of 25)

SIZE PACKING REQUIRED

/ (p 2 3 I.D. x 2.408 0.D. x al Width 96 Wraps Required Use M4 "

width Grafoil ribbon.

v I

Stem 3 r L 1

5 W /.623.. lL 3 "1 W S

Io l

[

1 I' '

Top cap j

p

/ 4..

,w, l l!

'4 'f b g

_ l 1

A oo.*.oc co i

f 1

i A

i i

l'2 AoSiffe.

f y "1 y Stuffing Box 9

f l

i m

00

. 7.s' C

h..

s..o c l

f f " 2 M4 Bottom Cap

/,630, ee, _-

Y

____________.____________.____.__________.._J

_L_

f"4 o,

ENCLOSURE 4 (Page 23 of 25)

SIZE PACKING REQUIRED

/. 7 4 7 I.D. x O 666 0.D. x ks. ~

Width MS Wraps Required Use 4

width Grafoil ribbon.

I o

i Stem 3s Vs4^

1 I_

d l

[~- /. 747

  • l*

3&Is W l

g

/.?ss e%o lb s

Top Cap o

2

/ m,,A h. 4 l i i

r

=

i l l l

E2"d !64 g

I

_l 1

2.5552.db i

l i

i i

i Stuffing Box

,12. ELrS l.*f%

_4 1

T 7

l I

e I

E i

z 2 5552.$4 l

~l

[

=

l l

l 4

44 2

.' F r

f l ** 4f 4

!*"7 b 0a$ coo?

~

I 64 Bottom Cap

,e

p ?; -,

s, 4

, i ENCLOSURE 4 (Page 24 of 25) o ST7.0 P.\\CK!!:0 RTOUTT5D I/c ~

width

[, 7 60 1.D. x 2,530 o.D. x l

.ll2-6 Wraps Required Use

/4 width Grc. foil ribbon.

I 1

I seem 3 "2 '/s4 I

f

?

d.

}~- ! ' so i.'& _

3E" b

f. 766Y=

~

S Top Cap g

p 7 3 +

2 E;L "d YG4 3

t 2.gw -t

- Oc ta l

i A

i

]

Stuffing Box l2 S'3OI.*4%1

/ k"t K,4 T

E i

i e

E

=

i

'a.. sao t c.t

~l I

& N fg&

E l

I g,qgg...s-[-[~

f I " '4 4 4

Bottom Cap

- ec o

~

.. -. 5..

. ~. ~.

~tr e g ENCLOSURE 4 (Pags 25 of 25) s.

SI P.\\C'* ? ':': QUIRED I \\]f(.,

Q. /2 5" I.D. x 3. OC.(o 0.D. x Width Q.00 Wraps Required Use I

width Grafoil ribbon.

i J,

i Stem 3't h4 I

r

. Col 3 k

M.4

?

.2. l 'h 5.*

h

,,,C P Cap g

p A

f f, z

/3, 4

l l

l' 9Ato t %.4' y

_ V 1

5 o,g....

.ca c i

I A

i s

Stuf fing Box I 3. 01(of.*M.

[k '4 2

A 4

~

f l

I i

c, t

4 3.01 G.0eo wg h

O Mg '3 Pg,y 7

~

M*lOS --oo. 2 l t

i ~1 Jf4

+.o.c z

Bottom Cap 1

iP r'

'32

  • ..a a-
  • g*4*,

I

. _,., j

,.c -

Io a

ENCLOSURE 5 SPLIT RING PUSHER (TYPICAL)

l f

Ll I;

I ly, l

yl I

I I

I I

Side View l

I I

I I

I i

g I

i l

i t

I O'

'O top view t

l Rev. 1 4

~

Page 71 MP-111

~'

^

.. =

g ENCLOSURE 6 PACKING RING FLTTURE (TYPICAL)

N GCT<s

@<s5

'//// j ///////// l//4 Yll A l

/

GRAFOI L RIBBO N PACKING STEM

~

s I

l TOP CA P i

i I

STUFFING BOX i

i s

I l

i B O T TO N C A P g

e4P-111 Rev.1 4 Page 72

s.

,a p..

([

W VALVE WORK RECORD ENCLOSURE 7 W;rk Request No.

FPC Tag No.

RWP No.

Torque Wrench Serial No.

Date A.

Packing Type Used (check) 187-I 1625 GF i

Grafoil GTN Ring Grafoil GTN Ribbon B.

Junk Ring Used Yes/No (circle)

(fill in)

Material C.

Lantern Ring (check)

Removed Reinstalled New Replacement D.

Consnents/P roblems l

1 i

Date List Completed By Date Approved By Rev.1 4 page 73 MP-111

~

f r..;... _

tA

)n PACXING RING SE0VENCE FOR VALVES ENCLOSURE 8 Number of Rings Below Lantern Ring Position

  • 3 4

5 6

7 8

1st 1625 1625 1625 1625 1625 1625 2nd Grafoil Grafoil Grafoil Grafoil Grafoil Grafoil 3rd 1625 Grafoil Grafoil Grafoil Grafoil Grafoil 4th 1625 Grafoil 1625 1625 Grafoil 5th 1625 Grafoil Grafoil 1625 6th 1625 Grafoil Grafoil 7 t'h 1625 Grafoil 8th 1625 Number of Rings Above L'antern Ring Position

  • 3 4

5 6

7 8

1st 1625 1625 1625 1625 1625 1625 2nd Grafoil Grafoil Grafoil 1625 1625 1625 3rd 1625 Grafoil Grafoil Grafoil Grafoil 1625 4th 1625 1625 Grafoil Grafoil Grafoil 5th 1625 1625 1625 Grafoil 6th

1625, 1625 1625 7th 1625 1625 8th 1625 NOTE: Contact the Mechanical Supervisor if there are less than three (3) rings above or below the lantern ring.
  • Position is from bottom to top, i.e., first ring is in bottom of stuffing box.

MP-111 Rev.1 21 Page 74

Ir ENCLOSURE 9 e

m.

GR AF01L*

"g RISBON-PACK r

CROSS SECTION CHART D-c em..

se

.,uar emssan.

sene= a.

r.r inn soe:mi...,a..,

\\

. ses m

4 o

G_

e a

7 g

. i e

12

~

to 14 a,

M 12 16

(-

. :/

COMPRESSION GUIDS k;E I-I,

E.l Garnerosa Cameress comorou Ca.noress t

1 inca

% inen v lacs

". inca

-e s

Ta fase to Taee to Taas to. Tage re G

b s:.::m P.am: a aas (Lasse 'wrwt M

3.ssesssve 4.ngs em ses rues.we araos "GAAfotL*.s a regretered tracemaru or unton Carnice Corporat.on F.

e',o**

u

~ sr,,

,, e Nray g C l

l l

Page 75 MP-111 Rev. 1 4 I

I%

i, e

GRAFOIL PRE-FORMED RINGS CHART ENCLOSURE 10 (Page 1 of 6)

VALYE PACKING GLAND STEM DIM.

GRAF0ll RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE AHV-1B 48 BF Pratt AHV-1C 48 BF Pratt ARV-48 6x6 RV Walworth ARV-49 6x6 RV Walworth ASV-5 4

GA Chapman 1-1/8 "

BSV-3 8

GL Aloyco 2.256" 1.498" BSV-4 8

GL Aloyco 2.256" 1.498" BSV-11 4

GA Aloyco 1.503" 0.998" BSV-12 4

GA Aloyco 1.503" 0.998" I'

16 10 GA Aloyco 2.285" 1.498" BSV-17 10 GA Aloyco 2.285" 1.498" BSV-36 4

GA Al oyco 1.503" 0.998" BSV-37 4

GA Aloyco 1.503" 0.998" C AV-1 1

GL Rockwell 1.287" 0.747" CAV-3 1

GL Rockwell 1.287" 0.747" CAV-4 1

GL Rockwell 1.287" 0.747" CAV-5 1

GL Rockwell 1.287" 0.747" CAV-126 1

GL Vel an 1.5" 7/8" CDV-41 16 GA Chapman 2-1/8 "

CDV-42 16 GA Chapman 2-1/8 "

CDV-43 16 GA Chapman 2-1/8 "

CDV-44 16 GA Chapman 2-1/8 "

5 14 GA Walworth 3.5" 2.5" MP-111 Rev.1 dl Page 76

.- w - -

4 GRn.0IL PRE-FORMED RINGS CHART ENCLOSURE 10 (Continued)

(Page 2 of 6)

VALVE PACKING GLAND STEM DIM.

GRAF0ll RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE CFV-6 14 GA Walworth 3.5" 2.5" CFV-11 1

GL Rockwell CFV-12 1

GL Rockwell CFV-15 1

GL Rockwell CFV-16 1

GL Rockwell DHV-3 12 GA Walworth 3.410" 2,370" DHV-4 12 GA Walworth 3.410" 2.370" DHV-5 10 GA Walworth 3.036" 2.120" DHV-6 10 GA Walworth 3.039" 2.122" 11 4

GA Aloyco DHV-12 4

GA Al oyco DHV-34 14 GA Aloyco 2.530" 1.750" DHV-35 14 GA Aloyco 2.530" 1.750" DHV-41 12 GA Aloyco 2.408 "

1.623" DHV-42 12 GA Aloyco 1.75" DHV-43 12 GA Aloyco 1.75" DHV-75 2-1/2 GA Velan 1.75" 1 -1/8 "

DHV-76 2-1/2 GA Velan 1-3 /4 "

1-1/8 "

DHV-91 2

'ut Velan 2-3 /8 "

1-1/8" DHV-105 2-1/2 GL Velan DHV-106 2-1/2 GL Velan DHV-110 10 GL

-111 10 GL MP-111 Rev.I dl Page 77

~

. s.

tr e

GRAr0IL PRE-FORMED RINGS CHART ENCLOSURE 10 r(Continued)

(Page 3 of 6)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE DWV-160 3

GA Crane 7/8" 1-13/32" 4

DWV-164 1

GA Yelan EFV-1 8

GA Crane 1-29/32" 1 -1/4 "

EFV-2 8

GA Crane 1-29/32"~

1-1/4 "

EFV-3 6

GA Crane 1-25/32" 1-1/8 "

EFV-4 6

GA Crane 1-25/32" 1-1/8 "

Cha' man 1-3 /4 "

EFV-7 6

p EFV-8 6

Chapman 1-3/4" i

EFV-11 6

GA Chapman 1-5 /8 "

i 14 6

GA Chapman 1-5 /8 "

i EFY-32 6

GA Velan EFY-33 6

GA Velan FWV-1 18 GA Chapman 2-1/8 "

FWV-2 18 GA Chapman 2-1/8 "

i FWV-7 18 GA Chapman 2-1/8 "

FWV-8 18 GA Chapman 2-1/8 "

FWV-14 18 GA Chapman 2-1/8" FWV-15 18 GA Chapman 2-1/8" FWV-22 18 CV Chapman 4-1/2" FWY-23 18 CV Chapman 4-1/2" FWV-24 Bypass AT & Morrill FWV-25 Bypass AT & Morrill i

26 GA Chapman 3-1/4 "

MP-111 Rev.1 d Page 78

s s

  • ~. * *
  • J e 1'

e st*,

'g f%

e A

GRk OIL PRE-FORMED RINGS CHART ENCLOSURE 10 (Continued)

(Page 4 of 6)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBB0H PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE FWV-27 GA Chapman 3-1/4" FWV-28 GA Chapman 3-1/4" Ft!V-29 GA Chapman 3-1/4" FWV-30 GA Chapman 3-1/4" FWV-31 10 GA Chapman 2-1/4 "

FWY-32 10 GA Chapman 2-1/4 "

FWV-33 6

GA Chapman 1-5 /8 "

l FWV-34 6

GA Chapman 1-5 /8 "

FWV-35 6

GA Chapman 1-5 /8 "

i 36 6

GA Chapman 1-5 /8 "

FWV-161 6

Bypass Fisher FWV-162 6

Bypass Fisher GSV-7 4

GA GSV-8 3

GA GSV-64 6

GA GSV-65 6

GA MSV-29 6

GA Chapman 1-1/2" MSV-30 6

GA Chapman 1-1/2" MSV-31 6

GA Chapman 1-1/2" MSV-32 6

GA Chapman 1-1/2" MSV-53 10 GA Chapman 2-1/8" MSV-54 10 GA Chapman 2-1/8 "

55 3

. Crane 1-29/32" 1 -1/4 "

MP-111 Rev. 1 4 Page 79

. 3 ;,.

_...v.

f%

i b

GRar01L PRE-FORMED RINGS CHART ENCLOSURE 10 (Continued)

(Page 5 of e)

VALVE PACKING GLAND STEM DIM.

GRAF0!L RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MSV-56 3

Crane 1-29/32" 1-1/4" M SV-57 3

GA Chapman 1"

M SV-58 3

GA Chapman 1"

MSV-179 5

GA Chapman 1-3 /8 "

MSV-180 5

GA Chapman 1 -3 /8 "

MUV-3 4

GA Yelan 2.130" 1.370" MUV-9 4

GA Yelan 2.125" 1.370" MUV-18 4

GA Walworth

1. 90 9" 1.250" MUV-23 2-1/2 GL Walworth 1.781" 1.121" 24 2-1/2 GL Walworth 1.783" 1.119" MUV-25 2-1/2 GL Walworth 1.782" 1.120" MUV-26 2-1/2 GL Walworth 1.782" 1.120" MUV-27 2-1/2 GA Walworth 1.413" 0.868" MUV-38 2-1/2 GA Walworth 1.413"
0. 86 8 "

MUV-39 2-1/2 GA Walworth 1.413" 0.868" MUV-40 2-1/2 GA Walworth 1.413" 0.868" MUV-41 2-1/2 GA Walworth 1.415" 0.868" MUV-53 4

GL Rockwell MUV-58 6

GA Aloyco 1.877" 1.248" MUV-62 6

GA Crane 1-29/32" 1-1/4 "

MUV-69 6

GA Crane 1-29/32" 1 -1/4 "

MUV-73 6

GA Aloyco

=

-112 2-1/2 GL Fisher MP-111 Rev.1 4l Page 80

,,g.

.m.,

f=

a TOIL PRE-FORMED RINGS CHART ENCLOSURE 10

,ntinued)

(Page 6 of 6)

VALVE PACKING GLAND STEM DIM.

GRAFOIL RIBBON PACKING TAG NO.

SIZE TYPE MANUFACTURER I.D. INCHES 0.D. INCHES REQUIRED SIZE MUV-257 4

GL Rockwell 1.810" 1.120" MUV-258 1

(M; Rockwell 1.287' O.747' MUV-259 1

GL Rockwell 1.287' O.747" MUV-260 1

GL Rockwell 1.287' O.747" MUV-261 1

(EL Rockwell 1.287" 0.747' RCV-11 2-1/2 GA Velan 1.209" 0.746' RCV-13 2-1/2 GA Walworth 1.415'

0.870' RCV-14 2-1/2 GL Walworth 1.415' O.870" RCV-53 2

GL

Velan 2-5/8"
1-1/4" SUV-10 10 GA

' Chapman 2-1/4" I-11 10 GA Chapman 2-1/4" WDV-3 4

GA Crane 1-17/32" 1'

WDV-60 2

GA Velan 1-1/4" 3/4" WDV-94 3

(H; Velan 1-9/16' 1'

WDV-247 1-1/2 GA Velan 1-1/4" 3/4" WDV-321 1-1/2 GA Velan 1-1/4" 3/4" WDV-405 1-1/2 GL Velan 1.88" 1.00*

WDV-406 1-1/2 GL Velan 1.88*

1.00" WDV-407 1

GL Velan 1-1/2"

'7/8" i

MP-111 Rev.1 4 Page 81 (LAST PAGE)

,u

-Tr :; ~ ~. :p.

,(

N l

p.

. M s

INFORMATION ADDITION FORM TO W-111 ENCLOSURE 11 Route to: Maintenance Engineering Date i

Valve Tag No.

Manufacturer Size t

Valve Type Gland I.D.

Stem 0.D.

l i

MP-111 Rev.1 4 Page 82 (LAST PAGE) i