Issue date | Title | Topic | |
---|---|---|---|
ML20211M665 | 1 September 1999 | Errata Page 4-45,reflecting Proposed Changes Requested in | |
ML20211D155 | 20 August 1999 | Proposed Tech Specs Pages,Revising Degraded Voltage Relay as-left Setpoint Tolerances | |
ML20210J126 | 29 July 1999 | Proposed Tech Specs Revising ESF Sys Leakage Limits in post-accident Recirculation Surveillance TSs | Hydrostatic |
ML20195E620 | 4 June 1999 | Proposed Tech Specs,Modifying Conditions Which Allow Reduction in Number of Means for Maintaining Decay Heat Removal Capability During Shutdown Conditions | |
ML20206R117 | 13 May 1999 | Proposed Tech Specs Section 3.1.1,incorporating Administrative Updating & Changing Bases Statement | Safe Shutdown Fire Protection Program |
ML20205H078 | 1 April 1999 | Proposed Tech Specs Adding LCO Action Statements,Making SRs More Consistent with NUREG-1430,correcting Conflicts or Inconsistencies Caused by Earlier TS Revs & Revising SFP Sampling | |
ML20203B051 | 2 February 1999 | Proposed Tech Specs Expanding Scope of Systems & Test Requirements for post-accident RB Sump Recirculation ESF Systems & Increasing Max Allowable Leakage of TS 4.5.4 for Applicable Portions of ESF Systems Outside of Containment | |
ML20196H536 | 3 December 1998 | Proposed Tech Specs Reflecting Decrease in RCS Flow Resulting from Revised Analysis to Allow Operation of Plant with 20% Average Level of SG Tubes Plugged Per SG | |
ML20196G486 | 3 December 1998 | Non-proprietary Proposed Tech Specs,Consenting to Transfer & Authorization for Amergen to Possess,Use & Operate TMI-1 Under Essentially Same Conditions & Authorizations Included in Existing License | Safe Shutdown Fitness for Duty Offsite Dose Calculation Manual Annual Radioactive Effluent Release Report Process Control Program Safeguards Contingency Plan Earthquake Minimum staff Fire Protection Program Siren Affidavit |
ML20196F866 | 25 November 1998 | Proposed Tech Specs Revised Pages for TS Change 277 Changing Surveillances Specs for OTSG ISI for TMI Cycle 13 RFO Exams Which Would Be Applicable for One Cycle of Operation Only. with Certificate of Svc | Operating Basis Earthquake |
ML20154Q627 | 19 October 1998 | Proposed Tech Specs Adding Operability & SRs for Remote Shutdown Sys Similar to Requirements in NUREG-1430, Std Tech Specs - B&W Plants, Section 3.3.18 | Safe Shutdown Post Accident Monitoring |
ML20154P866 | 19 October 1998 | Proposed Tech Specs,Providing Allowable RCS Specific Activity Limit Based on OTSG Insp Results Performed Each Refueling Outage | Hydrostatic Power change |
ML20249B242 | 11 June 1998 | Proposed Tech Specs Re Alternate High Radiation Area Control | High Radiation Area |
ML20217J820 | 25 March 1998 | Proposed Tech Specs Page 6-1,reflecting Change in Trade Name of Owners & Operator of TMI-1 & Correcting Typo | |
ML20217E531 | 23 March 1998 | Proposed Tech Specs Pages for Section 3.1.2 to Incorporate New Pressure Limits for Reactor Vessel IAW 10CFR50,App G for Period of Applicability Through 17.7 EFPY | |
ML20217G020 | 3 October 1997 | Proposed Tech Specs Re Revised Pages 4-80 & 4-81 Previously Submitted | Operating Basis Earthquake |
ML20211F378 | 24 September 1997 | Proposed Tech Specs Revising Steam Line Break Accident Dose Consequence | Power change |
ML20211C342 | 19 September 1997 | Proposed Tech Specs Pages 3.8-3.9b to TS Section 3.1.4 Providing More Restrictive Limit of 0.35 Uci/Gram Dose Equivalent I-131 & Clarifying UFSAR Analysis | Power change |
ML20211C243 | 19 September 1997 | Proposed Tech Specs Re Decay Heat Removal Sys Leakage | Hydrostatic |
ML20210K001 | 14 August 1997 | Proposed Tech Specs Revising TMI-1 UFSAR Section 14.1.2.9 Environ Dose Consequences for TMI-1 Steam Line Break Analysis | |
ML20141J405 | 12 August 1997 | Proposed Tech Specs Revising Surveillance Specification for Once Through Steam Generator Inservice Insp for TMI-1 Cycle 12 Refueling (12R) Exams Applicable to TMI-1 Cycle 12 Operation | Operating Basis Earthquake |
ML20198E794 | 30 July 1997 | Proposed Tech Specs Incorporating Addl Sys Leakage Limits & Leak Test Requirements for Systems Outside Containment Which Were Not Previously Contained in TS 4.5.4 Nor Considered in TMI-1 UFSAR DBA Analysis Dose Calculations for 2568 Mwt | Reactor Vessel Water Level Hydrostatic |
ML20151K207 | 25 July 1997 | Revised TS Page 6-19 Replacing Corresponding Page Contained in 970508 Transmittal of TS Change Request 264 | Shutdown Margin |
ML20141E149 | 8 May 1997 | Proposed Tech Specs,Consisting of Change Request 264, Incorporating Addl NRC-approved Analytical Methods Used to Determine TMI-1 Core Operating Limits | Shutdown Margin |
ML20140E247 | 21 April 1997 | Proposed Tech Specs 3.3.1.2,changing Required Borated Water in Each Core Flood Tank to 940 ft,4.5.2.1.b,lowering Surveillance Acceptance Criteria for ECCS HPI Flow to 431 Gpm & 3.3.1.1.f Re Operability of Decay Heat Valves | Fuel cladding |
ML20134M121 | 7 February 1997 | Proposed Tech Specs,Incorporating Certain Improvements from Revised STS for B&W plants,NUREG-1430 | Boric Acid High Radiation Area Offsite Dose Calculation Manual Annual Radioactive Effluent Release Report Annual Radiological Environmental Operating Report Process Control Program |
ML20133D282 | 24 December 1996 | Proposed Tech Specs 3.15.3 Re Auxiliary & Fuel Handling Bldg Air Treatment Sys | Reactor Vessel Water Level |
ML20132F330 | 16 December 1996 | Proposed Tech Specs,Reflecting Change in Legal Name of Operator of Plant from Gpu Corp to Gpu Inc & Reflecting Plant License & TS Registered Trade Name of Gpu Energy | Safe Shutdown Offsite Dose Calculation Manual Annual Radioactive Effluent Release Report Process Control Program Safeguards Contingency Plan Minimum staff Fire Protection Program |
ML20135D099 | 3 December 1996 | Proposed Tech Specs Incorporating Certain Requirements from Revised B&W Std TS,NUREG-1430 | Shutdown Margin Hydrostatic Power change |
ML20135C532 | 2 December 1996 | Proposed Tech Specs Re Relocation of Audit Frequency Requirements | Fire Protection Program |
ML20128H412 | 3 October 1996 | Errata to Proposed Ts,Adding Revised Table of Contents & Making Minor Editorial Corrections | Shutdown Margin Reactor Vessel Water Level Hydrostatic Annual Radioactive Effluent Release Report Annual Radiological Environmental Operating Report Process Control Program |
ML20117H045 | 29 August 1996 | Proposed Tech Specs,Consisting of Change Request 257, Incorporating Certain Improvements from STS for B&W Plants (NUREG-1430) | Shutdown Margin Power change |
ML20113D197 | 28 June 1996 | Proposed Tech Specs,Consisting of Change Request 259, Allowing Implementation of Recently Approved Option B to 10CFR50,App J | High Radiation Area |
ML20112C879 | 24 May 1996 | Proposed Tech Specs Re Pages for App A.Certificate of Svc Encl | Boric Acid Post Accident Monitoring |
ML20101R157 | 10 April 1996 | Proposed Tech Specs,Revising Addl Group of Surveillances in Which Justification Has Been Completed | Boric Acid Post Accident Monitoring |
ML20100J693 | 22 February 1996 | Proposed Tech Specs,Consisting of Change Request 254, Revising Proposed TS Page 4-46 on Paragraph 4.6.2 That Provides Addl Testing Requirements in Case Battery Cell Parameters Not Met | |
ML20095J231 | 21 December 1995 | Proposed Tech Specs,Raising Low Voltage Action Level to 105 Volts DC | |
ML20092K547 | 20 September 1995 | Revised Tech Spec Pages 4-31,4-32 & 4-33,incorporating Change in TS Section 4.4.1.5 | |
ML20091L291 | 23 August 1995 | Proposed Tech Specs Page 6-11a,incorporating Ref to 10CFR20.1302 | |
ML20087F492 | 11 August 1995 | Proposed TS Section 3.2 Re Makeup,Purification & Chemical Addition Sys Requirements | Probabilistic Risk Assessment |
ML20085N160 | 22 June 1995 | Proposed Tech Specs Revising Replacement Pages in Package & Remove Outdated Pages,In Response to NRC Request for Addl Info | |
ML20084L435 | 1 June 1995 | Proposed TS 5.3.1.1,describing Use of Advanced Clad Assemblies | Fuel cladding |
ML20084N350 | 1 June 1995 | Proposed Tech Specs,Deleting RETS & Relocating TSs Per Guidance in GL 89-01 & NUREG-1430 | Reactor Vessel Water Level Post Accident Monitoring Annual Radioactive Effluent Release Report Process Control Program |
ML20084B336 | 24 May 1995 | Proposed Tech Specs Re Change in Surveillance Test Requirements for source-range Nuclear Instrumentation | |
ML20083N784 | 17 May 1995 | Proposed Tech Specs,Consisting of Change Requests 252, Removing Chemical Addition Sys Requirements from TS to COLR | Boric Acid Shutdown Margin |
ML20079A781 | 23 December 1994 | Proposed Tech Specs Page 3-32a | |
ML20069A678 | 20 May 1994 | Proposed Tech Specs,Supporting Cycle 10 Control Rod Trip Insertion Time Testing | |
ML20065M683 | 19 April 1994 | Proposed Tech Specs,Reflecting Deletion of Audit Program Frequency Requirements | Offsite Dose Calculation Manual Process Control Program Minimum staff Fire Protection Program |
ML20065K045 | 11 April 1994 | Proposed Tech Specs Reflecting Relocation of Detailed Insp Criteria,Methods & Frequencies of Containment Tendon Surveillance Program to FSAR & Providing Direct Ref to Existing Tendon Surveillance Program | |
ML20073C773 | 22 March 1994 | Proposed Tech Specs Re Control Rod Trip Insertion Time Testing | Shutdown Margin Enforcement Discretion |