IR 05000250/1985021

From kanterella
(Redirected from ML20133A928)
Jump to navigation Jump to search
Physical Security Insp Repts 50-250/85-21 & 50-251/85-21 on 850522-24 & 0604.Violation Noted:Failure to Implement Compensatory Measures Following Loss of Security Sys Effectiveness.Details Withheld (Ref 10CFR2.790 & 73.21)
ML20133A928
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 06/19/1985
From: Ennis J, Mcguire D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20133A904 List:
References
50-250-85-21, 50-251-85-21, NUDOCS 8508060016
Download: ML20133A928 (1)


Text

._______ _ -

.

.

. UNITED STATES

[@ Kicg 'o NUCLEAR REGULATORY COMMISSION

[' g * 'n REGloN 11 g ,j 101 MARIETTA STREET. *' t AT L ANTA, GEORGI A 30323

\.~..*/

AUG 1885-Report No. 50-250/85-21 and 50-251/85-21 Licensee: Florida Power and Light Company P. O. Box 14000 Juno Beach, FL 33012 Docket No and 50-251 License Nos. DPR-31 and DPR-41 Facility Name: Turkey Point 3 and 4 Inspection Date1: May 22-24 and June 4, 1985 Inspector: Wh # de//V/8'f J(r fy D. Ennis, Physical Security Inspector Date S'igned Approved by: h 6 /I4/g5

$ 0. R. McGuire, Chie(\ Physical Security Section 0$e SFgned i y Nuclear Materials SMety and Safeguards 8 ranch Division of Radiation Safety and Safeguards '

.

SUMMARY Scope: This special, announced physical security inspection entailed 16 inspector-hours on-site reviewing the facts and circumstances surrounding two physical security events reported by the licensee in accordance with the provisions of 10 CFR 73.71(c).

Results: One violation was identified relating to the failure to implement approved compensatory measures in a timely manner following a loss of security system effectivenes '

.

l 8500060016 850001 INCt057'(0ppU, PDR ADOCK 05000250 0 PDR ggD 'ITO'.",f)T,tg W SEPARAD % y *