ML20126B623

From kanterella
Jump to navigation Jump to search
Notification of 820628 Meeting W/Util in Bethesda,Md to Review Results of Insp by Util Re Corrosion Damage to TMI-1 Steam Generators
ML20126B623
Person / Time
Site: Crane 
Issue date: 06/18/1982
From: Stolz J
Office of Nuclear Reactor Regulation
To: Novak T
Office of Nuclear Reactor Regulation
Shared Package
ML20126B295 List: ... further results
References
FOIA-84-897 NUDOCS 8506140156
Download: ML20126B623 (1)


Text

(~.

/

o, UNITED STATES l ' -V(f( i NUCLEAR REGULATORY COMMISSION c.

/r WASHINGTON, D. C. 20555

/%,

v June 18,1982 MC40RANDUM FOR: Thomas Novak, Assistant Director for Operating Reactors, DL i

FROM:

John Stolz, Chief, Operating Reactors Branch #4, DL

SUBJECT:

FORTHCOMING MEETING WITH GENERAL PUBLIC UTILITIES NUCLEAR (GPUN) RELATED TO THREE MILE ISLAND, UNIT 1 Time & Date:

10:30am-4:30pm Monday, June 28, 1982 Location:

Maryland National Bank Building Room 1713 Bethesda, Maryland

Purpose:

Review of results of inspections by GPUN related to corrosion damage to TMI-l steam generators.

Agenda:

10:30am-12:00 Noon Results of Reactor Coolant System inspection.

1:00pm-4:30pm Metallurgical examination results for removed tubes.

Requested

Participants:

NRC-RJacobs, CMcCracken. EMurphy Licensee-M. J. Graham, Scott Jacoby, et. al.

Other-NRC Consultants, GPU Consultants.

Jo Stolz, Chief OperatingReactorsBranch#4 ivision of Licensing cc:

See next'page e-4

'hf

l. fl.

- ~. '1A:k:'52

' SQ,$iE%

i

- y.- A

~~*: Qz

, ;,Y(1. 'iYC; 3

7

, ' 4 0

d UN 0506140156 850125 I

PDR FOIA DETJENB4-897 PDR

)/

u-m

.%