Submits Daily Highlight.Discusses ASLB 841031 Initial Decision on Steam Generator Repair.Decision Favorable. Authorities Issuance of Requested License Amend Recognizing Kinetic Expansion Repair Techniques Subj to NUREG-1019
ML20126B560
Person / Time
Site: Crane 
Issue date: 11/01/1984
From: Silver H
Office of Nuclear Reactor Regulation
To: Case E, Harold Denton, Eisenhut G
NRC
Shared Package
ML20126B295 List: ... further results
References
FOIA-84-897, RTR-NUREG-1019 NUDOCS 8506140136
Download: ML20126B560 (1)


Text

-

f" e.

\\

/

o UNITED STATES g

NUCLEAR REGULATORY COMMISSION o

g E

WASHINGTON, D. C. 20555

%,*..**/

{

November 1,1984 Docket No. 50-2C9 MEMORANDUM FOR:

H. Denton R..Vollmer E. Case R. Bernero G. Edison H. Thompson D. Eisenhut B. Snyder F. Miraglia T. S j

G. Lainas i

T. Novak

. Varga D. Crutchfield D. Vassallo J. Miller l

THRU:

John F. Stolz, Chief, Operating Reactors Branch #4, a'

j Division of Licensing N

i FROM:

Harley Silver, Project Manager Operating Reactors Branch #4, Division of Licensing

SUBJECT:

DAILY HIGHLIGHT - TMI-1 Steam Generator Hearing Initial Decision l

The staff today received the ASLB-Initial Decision on Steam Generator Repair dated October 31, 1984. The decision is favorable.

It authorizes issuance of the requested license amendment recognizing the kinetic expansion repair 7

techniques, subject to the conditions specified in the staff's SER, i

NUREG-1019, and Supplement I thereto. The decision adds two conditions which were discussed during the hearing, regarding (1) the installation and i

operability of a redundant secondary side radioactivity (leakage) monitor, and (2) considerations of eddy current examination after 180 days of operation at less than 50% power, should such operation occur.

The amendment package will be revised shortly and should be available for issuance by the end of November.

2 j

..n -.

Harley. Silver, Project Manager Operating Reactors Branch #4 Division.of Licensing I

l l

B506140136 850125 PDR FOIA DETJEN84-897 PDR c20b