Summary of 820615 Meeting W/Util & Franklin Research Ctr to Review Technical Status of Repair of Steam Generator Tubes to Achieve Better than Allowable Leak Rate
ML20126B656
Person / Time
Site: Crane 
Issue date: 07/07/1982
From: Gray H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20126B295 List: ... further results
References
FOIA-84-897 NUDOCS 8506140171
Download: ML20126B656 (2)


Text

w fN JUL 071982 MEMORANDUM FOR:

TMI Unit #1 - Docket No. 50-289 THRU:

Jacque P. Durr, Chief, Materials & Processes h Section, DETP FROM:

/ Harold Gray, Reactor Inspector, MPS, DETP

SUBJECT:

June 15, 1982, GPU MEETING ON STEAM GENERATOR EXPLOSIVE TUBE /TUBESHEET SEALING i

The meeting purpose was to review the technical status of the repair of Steam Generator Tubes to achieve a better than allowable leak rate. The plan is to explosive expand the tubes for a distance of about 10" into the tubesheet to achieve leak tightness.

The FRC (Franklin Institute Research) is contracted to the NRC to study, observe and conduct supplemental tests as required to monitor the explosive expansion development and later application to the steam generators.

Meeting attendees included GPU, FRC and NRC representatives.

The GPU presentation included review of the ACRS. report of 6/7/82 (portions ~

attached) and detailed presentation of the tube explodive expansion program.

/.rrangements were made for FRC to observe test shots at Foster Wheeler Corp.

(Livingston Research) during the week of 6/21/82 and for a follow-up meeting in Bethesda on 6/29/82 (Conrad McCracken - (301) 492-8595).

The Region I (H. Gray) concerns at this time as discussed with C. McCracken include:

1.

Will explosive expansion seal the type defects present at THI? Two (2) unusual factors include an Iron oxide layer in the tube holes and the factor of tubes being in tension when at ambient temperature.

2.

To what extent will tube elongation resulting during expansion change the tube loading (stress-) at ambient temperature?

3.

The plan as of 6/15/82 included plugging all tubes ( 1000) with defects below the 6" level from the top of the upper tubesheet.

The region based inspector questioned if other options would be evaluated such as expanding the 1000 tubes that would otherwise be plugged to below the 10" level (but not below the 22" level).

4.

Would the ordinance cord method of detonation result in a slight time delay between neighboring tube expansions? What are the time delay variables between the two types of detonation?

B506140171 850125 PDR FOIA DETJEN84-897 PDR M4

=

. ~..-

h g '. m.,

w

(';[

[

f fMIUnit#1

~

2 5.

Will individual; tube explosive loads be determined on the minimum or maximum. tube yield strength oi close to the yield strength of the

tube sheet ligament? What is the required grain / foot load for each of these conditions?
6. ~What. provision is in progress to provide a list of essential and non-

. essential variables similar to those in ASME Section XI, IWB 4453 for tube plugging by explosive welding?'

o WA4y Harold Gray Reactor Inspector cc: