Discusses Region IV Insp of Victoreen,Inc on 821101-05, Resulting from Deficiency Rept Re Quality Program & Mfg Deficiencies of Radiation Monitoring Equipment.Clarification of Evaluation Requested
ML20091M706
Person / Time
Site: Midland
Issue date: 04/13/1983
From: Hind J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Bangart R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML17198A223 List: ... further results
References
CON-BOX-10, FOIA-84-96 NUDOCS 8406120037
Download: ML20091M706 (1)


Text

,C $

p%

9 't UNITE D STATES M.

4,(

s4.d

[j

'j NUCLEAR REGULATORY COMMISSION j

REGION 111

7..g %.,'g.,

f C, g..' " -. ', f 199 ROOSEVELT ROAD

%, ' \\

-[

GLEN ELLYN ILLINctS 60137

=e,+<

April 13, 1983 MEMORANDUM FOR:

Richard L. Bangart, Director, Division of Vendor and Technical Programs, RIV FROM:

J. A. Hind, Director, Division of Radiological and Materials Safety Programs

SUBJECT:

VICTOREEN, INC. RADIATION MODULE DEFICIENCIES The Region IV Vendor Inspection Branch conducted an inspection of the Victoreen, Incorporated facility in Cleveland, Ohio, on November 1-5, 1982.

The inspection was made as a result of a Consumers Power Company 10 CFR 50.55(e) report concerning quality program and manufacturing deficiencies applicable to radiation monitoring equipment for the Midland Nuclear Power Station.

Your inspectors determined that the Victoreen, Inc. QA program failed to meet certain NRC requirements.

In response to the Region IV inspection report, Victoreen, Inc. stated, in their letter dated February 11, 1983, that an evaluation had been made to determine if the deficiencies with their workmanship standards constituted " defects" in accordance with the criteria specified in 10 CFR 21.

J It is not clear to us, from review of the Region IV inspection report (No. 99900377/82-01) and Region IV letter to Victoreen, Inc. dated March 17, 1983, whether Region IV agreed with Victoreen's evaluation that the identified deficiencies did not constitute " defects" per 10 CFR 21.

We would appreciate a clarification regarding this matter.

Thank you for your assistance in this matter.

Mr. L. R. Greger (FTS 384-2644) of my staff is available to discuss this matter further with'your staff as necessary.

ind,birector

. A.

Division of Radiological and Materials Safety Programs cc:

L. Cunningham, IE 4 Warnick, RIII J. Harrison, RIII i

G406120037 840517 l

PDR FOIA PDR RICEg4-96

.