Text
{{#Wiki_filter:.. 50- 62 1 { h.,,ki {,f,Sp*}-{,@@.r g DISTRIBJTION I / P-A l File /y i 00T 311979 LWR-4 File L. Rubenstein i D. Hood M. Service NRR Rdg. ItEMORANDUM FOR: L. S. Rubenstein, Acting Chief, Light Water Reactors Branch No. 4, DPH FROM: Darl Hood, Project thager, Light Water Reactors Branch No. 4 DPM l
SUBJECT:
TELECON FOR NOTIFICATION ON SUMP SCREEN DEFICIENCY
REFERENCE:
" Summary of Trip to Observe flidland Sump Tests" dated 9/17/79 On 10/31/79 at 8:45 am I received a call from Messrs. Mike Salerno and Jim.Zabritski of Consumers Power Company regarding the referenced trip sumary of a staff visit to observe a containment sump test. The call was with regard to our requirement stated in the trip report that the B&W concern regarding core blockage must be further explained and evaluated. Mr. Zabritski advised that our concern had been forwarded to B&W for resolution. Mr. Salerno confim.ad that the requirement for a fine mesh (0.04 inch) sump screen results from a B&W concern resulting from trapping of fine particles-(e.g., foam glass insulation) between the fuel spacer grid and fuel elements which is postulated to continue during the post-LOCA recirculation node until fuel blockage in excess of that used in Appendix K analyses results. The .aMition of t'1e fine screen in the itidiand design results from the applicant's i inability to verify that such a significant extent of blockage could not other-wise occur. 1 The concern was recognized to be generic to other PWR plants in addition to Midland, llessrs. Salerno and Zabritski were not aware of why other B&W plants did not have similar screens in response to the B&W concern. The concern brings into question the conservativeness of LOCA analyses and assumptions. A prompt review should be perfomed to determine whether ASLB notifications are in order. Origina$ signed by: Darl Hood, Project flanager - Light Water Reactors-Branch !!o. 4 Division of Project !!anagement i cc: R. Mattson D. Vassallo V. Stello S. Hanauer S. Varga H. Thornburg fS11160%,g>,4 l T. Speis,. .M. Williams D. Ross y..,,,,, u... n ,___i.... L DPMhR-4 _Dk M m.a
- DHood/jl M_LR h.
n Y Y##I 841N-M co m.-, 10/3l /79 10/ 9 4 ac.m macm.u..
- o......-....
nnA o a - y,3; -}}