  • [anc\\o UNITED STATES j

~,

NUCLEAR REGULATORY COMMISSION 7

E REGION iil

'f 7P9 RooSEVELr AoAo o

%.....[

oLEN ELLYN,ILLINolS 60137 MAY 1 3 G03' MEMORANDUM FOR:

D. G. Eisenhut, Director, Division of Licensing, NRR FROM:

R. F. Warnick, Director Office of Special Cases

SUBJECT:

RECOMMENDATION FOR NOTIFICATION OF LICENSING BOARD In accordance with present NRC procedures regarding Board Notifications, the following information is being provided as constituting new information relevant and material to the Midland OM/0L proceedings. This information deals with the licensee's May 9, 1983 decision to stop Recedial Soils work due to violations of applied Hold Tag requirements.

The pertinent facts that relate to the stop work are as follows:

1.

On May 6,1983, MPQAD issued a nonconformance report (NCR) to document drift set deficiencies identified on previous Remedial Soils installa-tions. As a result of the NCR, Hold Tags were applied.

2.

On May 7,'1983, MPQAD issued an NCR to document drift set deficiencies identified during installation of pier KC-2 (East). As a result of the NCR, Hold Tags were applied.

2.

On May 9,1983, the licensee determined that work had continued on pier KC-2 (East) despite the presence of the Hold Tags. An additional NCR was issued to document the Hold Tag violations. At noon on May 9, 1983, the Field Soils Organization (FSO) stopped Remedial Soils work activities due to the Hold Tag violations. Although a formal Stop Work Order was not issued, 53 workers were sent home.

4.

At 8:00 a.m. on May 10, 1963, the licensee resumed Remedial Soils work activities. The resumption of work was allowed after a resolution of differences between MPQAD and FSO pertaining to the cignificance of NCR!s and Hold Tags. The NRC was informed of the Remedial Soils stop work by Stone and Webster (S&W) personnel during their meeting with the Midland Resident Inspectors to discuss the monthly S&W report of Remedial Soils work activities.

i

  • I B406020127 840517 1

PENT FOI A I

RICE 84-96 PDR 1

D. C. Eisenhut MAY I 3 P3 If you have any questions or desire further information regarding this matter, please call me.

N D

(\\.0 pv R. F. Warnick, Director Office of Special Cases f

cc:

A. B. Davis J. J. Harrison R. N. Gardner R. B. Landsman R. J. Cook i

4 e

i j

?

?

O 4,

~

,l h

t 1

h a

i, ~'.l

,q-.

g.

w 4

5 g

e_.

4 bb')7.bb'k A

MIDLAND NUCLEAR SITE FACILITY DATA Facility Description 1.

Location Midland, MI (Within City Limits) 2.

Electric Reliability Council NA 3.

Type of Reactor PWR 4.

Power Level (MVT) 2552 5.

Design Electrical Rating (MWE Net) Unit 1 - 492, Unit 2 - 818 6.

Date of Initial Criticality NA 7.

Date of Commercial Operation NA 8.

Condenser Cooling Method Cooling Pond 9.

Condenser Cooling Water Source Tittabawasee River Utility & Contractor Information 10.

Licensee Consumers Power Company 11.

Corporate Contact James W. Cook, Vice President Midland Project (517) 788-0453 12.

Corporate Address 1945 W. Parnall Rd.,

Jackson, MI 49201 13.

Architect / Engineer Bechtel (517) 788-0453 14.

Nuclear Steam Supply System Babcock & Wilcox 15.

Constructor Bechtel Pirnt Contacts D. L. Quamme, Site Manager (517) 839-6458 R. Wells, Executive Manager, MPQAD (517) 83S-6389 Switchboard (517) 839-6000 i

Plant Address 3500 Miller Road Midland, MI 48640 i

e f

'}

1 l

l 3'

i Regulatory Information 16.

IE Region responsible III 17.

IE Branch Chief R. F. Warnick, Chief, l

Projects Branch 1 (312) 790-5575 18.

Section Chief J. J. Harrison (312) 790-5635 19.

IE Project Manager R. N. Gardner (312) 790-5524 1

20.

IE Senior Resident Inspector R. J. Cook (517) 631-7807 (Res.)

(517) 631-8150 (Office) 21.

IE Resident Inspector Bruce L. Burgess (517) 835-3537 (Res.)

(517) 631-8150 (Office) 22.

IE Resident Inspector Patrick L. Hiland (517) 695-9308 (Res.)

(517) 631-8150 (Office) 23.

Licensing Project Manager Darl Hood (301) 492-8402 24.

Docket Number 50-329; 50-330 25.

License Number /Date of Issue CPPR-81; CPPR-82 12/15/72 26.

Public Document Room Grace A. Dow Memorial Library 1710 W. St. Andrews Road Midland, MI 48640 s,

4 I.

i

~I

.(

~

n "N p g-T fwe g

. CORSum8IS Power Stue Manager i

COmpBRy uea a

u.aiana pro,.ci. ro saa toes. u.s.ne. un 4se4o. <sta est-ses File:

16.0, 0460.3, 0505.2 Serial: CSM-0746 March 13, 1984 l/PRIN0lPAL STAFF p1 m

DPRP Mr J J Harrison C/AA 3E

  • i/RA DRMSP US Nuclear Regulatory Commission

/

Region III DyiA

/

,g V

799 Roosevelt Road 43 SCS g

Glen Ellyn, IL 60137 fA

'4L File s g MIDLAND ENERGY CENTER PROJECT -

REQUEST FOR APPROVAL OF RELEASE OF INS?ECTION ACTIVITY ASSOCIATED WITH VERIFICATION OF NCR REWORK Per our discussion of 3/7/84, this letter documents our request to obtain approval for release of inspection associated with verification of rework as a result of an NCR rework disposition regardless of what module the action item is in.

There are approximately 750 nonconformance reports for which rework had previously been acconplished per the NCR disposition, but the verification inspection had not been accomplished prior to the general halt of inspection activities. Any such inspections are completely controlled by the existing MPQAD procedures.

Your concurrence to this request will be appreciated.

/

s

/

th -

l WRB/DLQ/jkd CC JGKeppler, Administrator, Region III RJt'ook, NRC Resident Inspector, Midland DSHood, USNRC h

~-

MR22 w OC0384-0001A-QLO3 d

i

s

'*i' OM/ot $ERVI.b; LIST Mr Frank J Kelley Atomic Safety & Licensing Attorney General of the Appeal Board State of Michigan U S Nuclear Regulatory Commission Ms Carole Steinberg Washington, DC 20555 Assistant Attorney General Environmental Protection Division Mr C R Stephens (3) 720 Law Building Chief. Docketing & Services Lansing, MI 48913 U S Nuclear Regulatory Commission Office of the Secretary j

Washington, DC 20555 Mr Myron M Cherry, Esq Suite 3700 Ms Mary Sinclair Three First National Plazar,' '-

57.11 Summerset Street

, '* ' Hidland MI 48640..

Chicago, IL 60602 Mr Wendell E Marshall Mr William D Paton, Esq RFD 10 counsel for the NRC Staff Midland, MI 48640 U S Nuclear Regulatory Commission Washington, DC 20555 Mr Charles Bechhoefer Esq Atomic Safety & Licensing Atomic Safety & Licensing Board Panel Board Panel U S Nuclear Regulatory Commission U S Nuclear Regulatory Connaission East-West Towers, Room E-413 Washington, DC 20555 Bethesda, MD 20014 Ms Barbara Stamaris Dr Frederick P Cowan 5795 North River Road 6152 N Verde Trail Rt 3 Apt B-125 Freeland, MI 48623 Boca Raton, FL 33433 Dr Jerry Harbour Mr Fred C Williams Atomic Safety & Licensing Isham, Lincoln & Beale Board Panel 1120 Connecticut Ave, NW, Suite 840 U S Nuclear Regulatory Commission Washington, DC 20036 East-West Towers, Room E-454 Bethesda, MD 20014 Mr James E Brunner, Esq Consumers Power Company Mr M I Miller Esq 212 West Michigan Avenue Isham, Lincoln & Beale Jackson, MI 49201 Three First National Plaza i

52nd Floor i

Mr D F Judd Chicago, IL 60602 Babcock & Wilcox -

4 l

PO. Box 1260 Mr Jofin Demeester, Esq Lynchburg, VA 24505 Dow Chemical Building

~ Michigan Division Mr Steve Cadler, Esq Midland MI 48640 2120 Carter Avenue St Paul, MN 55108 Ms Lynne Bernabei Government Accountability Project 1901 Q Street, NW.

3/8/84 Washington, DC 20009 I

MIO983-0002A-MPO4 j

~

~

1

~ - --

L. --l-

--+a

'