05000387/LER-1983-066, Updated LER 83-066/03X-1:on 830414,during Mod to Remove Check Valve,Valve Disk Found Lodged in Pipe & Various Small Valve Parts Missing.Caused by Extensive Sys run-time During Resolution of ESW Waterhammer problem.W/840307 Ltr

From kanterella
(Redirected from ML20087N251)
Jump to navigation Jump to search
Updated LER 83-066/03X-1:on 830414,during Mod to Remove Check Valve,Valve Disk Found Lodged in Pipe & Various Small Valve Parts Missing.Caused by Extensive Sys run-time During Resolution of ESW Waterhammer problem.W/840307 Ltr
ML20087N251
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 03/07/1984
From: Keiser H, Kuczynski L
PENNSYLVANIA POWER & LIGHT CO.
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
LER-83-066-03X, LER-83-66-3X, PLA-2124, NUDOCS 8404030266
Download: ML20087N251 (3)


LER-2083-066, Updated LER 83-066/03X-1:on 830414,during Mod to Remove Check Valve,Valve Disk Found Lodged in Pipe & Various Small Valve Parts Missing.Caused by Extensive Sys run-time During Resolution of ESW Waterhammer problem.W/840307 Ltr
Event date:
Report date:
3872083066R00 - NRC Website

text

-

  • - - Update Report - Previous Report Dato 5/13/83.

NA7 POIM 366 U.S. RUSLCAD GSOULATCQV ggMMg% GIN A,P!iGVID CY OM[

8 88504888

'%'el8,4se LICENSEE EVENT REPORT (PLEASE PRINT OR TYPE ALL REQUIR.D INFORMATIONI CONTROL 8 LOCK: l l l l l l l@

I oli llP l A............

l S l E l Sl 1l@l0 l0 l- 10 l 0l 010 l0 l-l 010l@l4 m...... ...... ..

l1 l1 l1 l 1l@l l

l@

CON'T L,od, "!:!"; LLJ@l0151010 l 0 l 318l 7l@l014 l li 41813l@l01310l 718l 4l@

EVENT DESCRIPTION AND PROBABLE CONSEQUENCES @

o2 l During the inplementation of a plant modification to rmove the internals of a l 0 3 l Pacific check valve in the Emergency Service Water Systs to correct a recognized I lo 14 l l deficiency in those valves, the valve disc was found lodged in the pipe and vari- l

[ojsjlous small valve parts were missing. There were no adverse conscauences in that I l o le l l adeauate systs flow was achieved each time the systs has been started. l

[o17ll l loisll l

  • ="
    • "# .3:"::. ....... .... .#c":,;. .:=.

lo ls l lW lG l @ W @ l B l @ l Vl AlL lV lE l X l @ [ C_J @ y @

, . . .. ,, ,, u .. .. u

....,....  :::#,"!.'*.' **S"::"** " ";" ' " " 7.' l*"

1 @ UE.""'._ I8 ..

13 I o

l--J u

l0l6l6I

.. . l./,_J l0l3I L..xj I-l L.1_j

= :: ==  ::=, ==" ..... @ :::=n' ,:.=.. '".'#,='-  ::.r::,u'..@

l Lz_J808 u u Lz_JO u Lz_]@

a l 01 01 010 I L.,YJO I Ni@ [ A_J @

., .. u o lP a

l0 13 l2 ul CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Or>

l i lo l l Check valve wear was caused by extensive system run-time during the resolution of I l 1 l 1 l l the ESW water hamner probim encountered last year. A generic probim with other l l t i 2 l l Pacific check valves has been identified and a program developed for their test- l l i I a l I inm I ITTTlI ~

l

'.",1't','.' s ... ...........

@ l ",".= '

................... g

[ TIT 1 l B l @ l 0 l 0 l 0 l@l NA (C_j@l Technical Personnel Observation l

, .. ,. u .. u .

..L. ... ..L. . M O U N, O, . .,l V I . , LO C . lO N O , . . L . . . .

l ii si. .W @ W@l NA n

l l NA l

NUM... .... . . . C . I.. PN IiI7I M.. d,,@ W @l NA l

.. . .O NN .L INJU. I. .

1 8 l0l0l0l@l NA 8404030266 840307 "

'.*........'.'....','....,<,,'@ PDR ADOCK 050003R7 s.... ........... s pog I ii o I L.zj@l NA l

i. .u . [." "'. .'. .'. i., s o m h NRC USE ONLY I a l o l L.R]@l NA l lllllllllllll NAME OF PREPARER b. A.15uCZV" ski PHONE.(717) 542-2181 X3759

ATTACHMENT LER # 83-066/03X-1 Pennsylvania Power &' Light Company .

Susquehanna Stean Electric Station Docket Number: 50-387 A plant nodification was authorized to eliminate the abnonnal wear concern on various Pacific check valves in the Dnergency Service Water (ESW) systs.

mis nodification includes removirs four affected check valves and replacing thcm with butterfly valves and renoving the internals of two other check valves. It was during the internals renoval of one of the check valves tnat the condition which precipitated this LER was discovered. hhen the valve was dis-assabled, the valve disc was found lodged in the pipe and the cotter pin and put were missing. Engineering evaluation has con-cluded that the cotter pin does not provide a hazard to system operation.

h e nut is large enough to cause the ESN bypass valve to malfunction.

An inspection of a portion of the ESW pipiry was performed and the nut was not found.

Other check valves which are subject to similar wear conditions as the one which failed will be tested and monitored under the Susquehanna Inservice Teating Program for Pumps and Valves.

Work has been canpleted to tie the Unit 2 ESW and RHRSW piping into the line in which the nut may be contained. There was sufficient flow in the piping during the ESW/RHRSW full' flow testing that, if the check 1 valve nut were in the pipirg, it is reasonable to assume that it was flushed into the spray pond where it poses no threat to plant equipnent.

A hydrostatic test was performed on the line after the flow testing which verified the leak-tight integrity of the ESW bypass valve. Based upon the above, no further actions will be taken to locate the missing nut. - -

- - . - ~ - . , , . ._

Pennsylvania Power & Light Company ,

Two North Ninth Street

  • Allentown, PA 18101
  • 215/770 5151 gg7 ggg4 Dr. T.E. M1rley Regional Administrator, Region I U.S. Nuclear Regulatory Ccmnission 631 Park Avenue King of Prussia, PA 19406 SUSQUDIANNA STEAM ELELTRIC STATIM LICENSEE EVENT REPORT 83-066/03X-1 ER 100450 FILE 841-23 Docket No. 50-387 PIA-2124 License No. NPF-14

Dear Mr. Allan:

Attached is updated Licensee Event Report No. 83-066/03X-1, which des-1 cribes subsequent amlyses regarding inspection to locate missing check valve nut in ESW piping.

H.W. Keiser Superintendent of Plant-Susquehanna IAK/pjg Attachment cc: Director of Nuclear Peactor Regulation Attention: -Mr. A. Schwencer, Chief Licensing Branch No. 2 Division of Licensing U.S. Nuclear Regulatory Ccmnission Washington, DC 20555 G.G. Rhcads Resident Inspector U.S. . Nuclear Regulatory Ccmnission P.O. Bax 52 Shickshinny, PA 18655

/

V

+