._. .._ _.._ _ _.m,__

I Le .

- . ,._,p.o ._..4 i . , ...... 4,,, a m .o . . , m mm.m,,,,, ,U* !** NUG L'** '8'% UL ^ 8 V8 6Y COMM'.;*'* 8V" e LG s ef.e..) Ms,* '

" ucumEE EVENT HEPOWf (PLCASC PHINT Oil TYPC ALL REQUlHCO INFOilMATIOM GU NTe40L ut.OGM ,

] l _ )), ,

o lh l- l0 l0 j@[4 l LICLNh6 lj_111J2JGL.U bl Ga T bJ O~.0 j N1 J j O_j,C j Pl 1 j@llb 0 l 0 l -l 0 l LICLN*es I4 0 l 0-NUMOLH l0 [0 Jb b TYPL JJ b U LIGLtd5LC CQOL Jo w MJ [aj/$ [Lj @ M l 5 10 1 0j_0 l 2 l 1 l 9 l@63l1 (4 LVENT O ATC l212J9 l8l1l@l0 74 7;r HLPQ3T OATCl1l2lRIR 40 l?l 6 GO bl OOCK LY NUMc CH cvcN r Ocs,calPTION AND PROUAULE CONSEQUENCC5 h i Tij l During routine surveillance of Core Spray Systcm I, parallel isolation valve V-20-l'5 bemme inoperable in a partially open position. The cir-M]l cuit' breaker for the notor operator tripped when theactuation pressure g; [

g(j , sensor was reset. A parallel valve V-20-40, which is actuated by the

~[, j L same pressure sensor, operated normally. The valve was stroked to j

,3 j;. ; determine operability and surveilled again without incident. The y safety significance of this event is considered mmimal. ut CAUGC COMP. VALVC

vsTC M CAUSC GOfMONCNT;OUs SUCCOO OOS4 .4004 SVGCG;4

{ l S l Fj @ [X]@ l Z l @ , l C l K l T l B l R j K i@ sb4000C[Al@ N W @C a ou  :: 12 JJ to 19 OCCUAACNCC RCPORT HGV8 MON S C OU C NT8 A L.

H LPon T NO. coOc rvPC No.

. . .t v n n .s. .

O Ji'y.;'g,',

l.8 ll 22I l-l 1 017l21 1 'I I 013 I ILI 38 L- .-J Lo_J J3 2J 34 M 27 20 33 30 28 Al"f ACHM C NT NPR D-4 P81ME COMP. COMPONCNT mTrors r t ti m r. C F r:CCT S6euTOOWN ,,

PORM 400. SUPPUf 8 MAN')FACTUNCH ONPLANY METHOD HOUH' " 4UOMITTCO 4 AK s.f 4 l.uX_j@la X.j@

ACTION l.Z_ j@ l Z_j@ [ 0l 0 f 0 l l [Y_j @ lYl@ l42Nl@ lG l0 l8 D l as da 4s 42 .s4 di a, aa cAusc ocScaieTicu ANo cosaccTavE ACTIONG h 7,i j l The apparent cause of the occurrence was the high notor current drawn l'Ej l when a valve close signal was inadvertently initiated durinct the period i All associated electrical com- l ICO l... _.whe_n_ t;he valve was still stroking open.

g[ ponents were functionally tested and found satisfactory. Engineering  ;

7jj is currently analyzing this problem. ,

so a > MCTHOD OF s' C H.a Ty *

% PCWLin OTHCHSTATUS 015COVt'8Y O!5COVCHY OC.CRIPTION uAiu; E j j.Ji.,J @ l 0 l 0 l0,j@l NA 44

[ lB l@l4G Surveillance Test 4G gg l

4 7 10 12 l')

CONTCNT LOCATION QP HC'.CA&E 30

,ts; a lV8TY 3U stLLCALLO Ol'4CLEASC AMOUNT OI: ACTQ4W NA Tl

~.

l aj 9 ! z l@L_ 10 NA

.a4

( (

45 gg l

u - 11 t'UtSONNLL LiXPO50AC:1 NUUuCA TYPC O iSCRIPTION NA l 3"i_" 01 0 l Ol@l z l@])l." '

,.w SO~N d.'muLs OesCnc.,@

NuMoen NA D Loj 01 0l@ L.. -

GJ l

b Il 32 ,

LO:.L Of Qll Q A.'.t ACC TO it 8' g-TYPL O C 5C Ain' TION .

blZ}@!

V 8202090290 820128

.. NRC USE ONLY C5CHiPTION ('

PDR ADOCK 05000219 ,

iwut NA S PDR llll llllgl l9lg

,] LN l l

GG G9 49.;

' , . su

  • Hamid Pirooz 609-971:4418 ^

e

s. A u .: ncon,. ..

re.o"e . _ - - - _ _