Monthly Operating Rept for Oct 1998 for Oyster Creek Nuclear Generating Station.With
ML20155J302
Person / Time
Site: Oyster Creek
Issue date: 10/31/1998
From: Egan D, Roche M
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
1940-98-20644, GL-97-02, GL-97-2, NUDOCS 9811120096
Download: ML20155J302 (3)


Text

i e'

t

{

GPU Nuclear,Inc.

(

U.S. Route #9 South NUCLEAR Post Office Box 388 Forked River, NJ 08731-0388 Tel 609-971-4000 November 5, 1998 1940-98-20644 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555

Dear Sir:

SUBJECT:

Oyster Creek Nuclear Generating Station Docket No. 50-219 Monthly Operating Report - October,1998 Enclosed are two copies of the October,1998 Monthly Operating Report for Oyster Creek Nuclear Station. The content and format ofinformation submitted in this report is in accordance with the guidance provided by Generic Letter 97-02.

If you should have any questions, please contact Ms. Brenda DeMerchant, Oyster Creek Regulatory Affairs Engineer, at 609-971-4642.

Very truly yours, 1

'C Michael B. Roche

' Vice President & Director 1

Oyster Creek

.j

MBR/BDeM/gl Enclosures cc:

Administrator, Region I (2 copies)

NRC Project Manager NRC Sr. Resident Inspector i

9811120096 981031 3

PDR ADOCK 05000219 R

PDR

4

~

e.

APPENDIX A Operating Data Reoort Docket No:

50-219 Date:

11/02/98

- Completed By:

David M. Egan Telephone:

(609)971-4818 1

i Reporting Period:

October 1998 i

YEAR TO MONTH DATE CUMULATIVE 1.

DESIGN ELECTRICAL RATING (MWe NET).

J The nominal net electrical output of the umt specified by the utility and used for the purpose of plant design.

650 2.

MAXIMUM DEPENDABLE CAPACITY (MWe NET).

The gross electrical output as measured at the output terminals of the turbine generator during the most restrictive seasonal 619 conditions minus the normal station senice loads.

3.

NUMBER OF HOURS REACTOR WAS CRITICAL.

The total number of hours during the gross hvurs of the reporting period that the reactor was critical.

0 6044.4 175,886.6 4

HOURS GENERATOR ON LINE.

(Service Hours) The total number of hours during the gross hours 0

5957.6 172,040.7

)

of the reposting period that the unit operated with the breakers closed to the station bus. The sum of the hours that the generator l

was on line plus the total outage hours in the reporting period.

5.

UNIT RESERVE SHUTDOWN HOURS.

7he total number of hours during the gross hours of the reporting 0

0 918.2 period that the unit was removed from senice for economic or similar reasons but was available for operation.

6.

NET ELECTRICAL ENERGY (MWH).

l The gross electrical output of the unit measured at the output 0

3,606,630 96,888,479 terminals of the turbine generator minus the normal station senice loads during the gross hours of the reportmg period, expressed in magawistt hours. Negative quantities should not be used.

  • Design values have no " Year to Date" or " Cumulative" significance.

I '.

h

Q 4

. Appendix B I

^ -

Unit Shutdowns Docket No:

50-219

[

Date:

11/2/98 Completed By:

David M. Egan Telephone:-

(609)971-4818 l

i Reporting Period:

October 1998 i

E No.

Date Type

  • Duration Reason' Method of Cause & Corrective Action to i

(Hours)

Shutting Down Prevent Recurrence t

Reactod 9

9/26/98 S

745.0 C

1 ne plant remained shutdown for its 17R outage.

[

v i

f a

I 2

F Forced Reasort hiethod:

[

S Scheduled A-Equipmerd Failure (Explain)

I-klanual t

B-htaintenance or Test 2-klanual Scram C-Refueling 3-Automatic Scram y

D-Regulatory Restriction 44Mher (Explain)

L F, Operator Training & Licensing Examination F-Administrative l

G-Operational Error (Fxplain)

II-Other(Explain) f i

th Summary:

For the entire month of October 1998, Oyster Creek was shutdown for its 17 refueling outage.