ML20039G382

From kanterella
Jump to navigation Jump to search
Advises That B&W Will Use Staff Mods from Facility Cycle II for Power Spike Model.Issue Will Remain Open on a Generic Basis
ML20039G382
Person / Time
Site: Oconee 
Issue date: 07/23/1974
From: Lobel R
US ATOMIC ENERGY COMMISSION (AEC)
To: Ross D
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML111090060 List: ... further results
References
FOIA-80-515, FOIA-80-555 NUDOCS 8201180130
Download: ML20039G382 (1)


Text

_

l ijk"q b' 'l y;t 23 94 l-D. F. Ross, Chief. Core Perforn3nce Branch, L' PRESENT STATUS OF B&W POWER SPIKE H0 DEL On July 17, 1974 I received a ca-1 from James Harrison,of B'abcock & Wilcox.

lie wished to discuss the implications of the Staff's position on the B&W Power Spike model on Oconce I Cycle II. The Staff recently told B&W that their power spike model was acceptable if they would make the following rodifications:

(1) Assum a linear distribution of gap probability.

(2) Assume 0.5 gaps / rod.

B&W feels that these assumptions are too stringent but they lack the data to present a stronger case at this time. Therefore, after some discussion we agreed on the following plan of action..B&W will use the Staff modifications for Oconee I, Cycle II and the Staff will leave the issue open on a generic basis until the time when B&W is able to respond to the Staff's concerns.

Richard Lobel Core Performance Branch Directorate of Licensing cc:

S. Hanauer c.., _

J. Hendrie V. Stello L. Rubenstein

's B. Siegel

[

DISTRIBUTION: Central File CPB Reading LReading(M.Groff)

R. M. Lobel J

R. O. Myyer a

/

\\

_s.,

CPB:L CPB:L CPB:L

/,

RGlobel:dsm LSRubenstein DFRoss 7/ /74 7/ /74 7/ /74 8201100130 810403 PDR FOIA MADDEN 80-515 PDR