Text
.
m
@ *EQoq*
o UNITED STATES f
NUCLEAR REGULATORY COMMisslON g.
t WASHINGTON. D. C. 20S55
\\;.' /
MAR 131978 Docket Nos.:
50-329/330 MEMORANDUM FOR: D.B. Vassallo, Assistant Director for LWR's, DPM FROM:
P.E. Norian, Section Leader, Analysis Branch, DSS THRU:
?.R. Rosztoczy, Chief, Analysis Branch, DSS
SUBJECT:
FIRST ROUND QUESTIONS MIDLAND PLANT UNITS 1 AND 2 ON STEAMLINE BREAK AND FEEDLINE BREAK ANALYSIS Plant Name: Midland Plant, Units 1 and 2 Docket Nos.:
50-329/330 Licensing Stage: OL Responsible Branch and Project Manager:
LWR-3, D. Hood Technical Review Branch Involved: Analysis Branch Description of Review:
First Round Questions Requested Completion Date: February 10, 1978 Review Status:
Continuing The Analysis Branch has reviewed Sections 15.1.5 and 15.2.8 of the Midland Plant FSAR. These sections concern with the consequences of the steamline and feedline break accidents.
The enclosed list defines specific additional information needed to continue our review of the cited sections.
f.E-Q P.E. Norian, Section Leader Analysis Branch Division of Systems Safety
Enclosure:
As stated cc:
S. Hanauer Z. Rosztoczy R. Mattson P. Norian R. Boyd S. Salah F. Schroeder T. Novak D. Ross J. Mazetis
- 0. Parr S. Newberry D. Hood
Contact:
S. Salah, NRR, 27911 8006240 h 7