LER 81-046/03L-0:on 811201,control Bldg Ventilation Sys Exhaust Isolation Damper Failed to Close Rendering a Control Room Standby Filter Unit Inoperable.Caused by Misalignment of Damper Operator.Repair Procedure to Be Corrected
ML20039D503
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 12/22/1981
From: Varner D
IES UTILITIES INC., (FORMERLY IOWA ELECTRIC LIGHT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20039D502 List:
References
LER-81-046-03L, LER-81-46-3L, NUDOCS 8201050070
Download: ML20039D503 (2)


Text

. . _ . . .. . . ~ - -

Niic PCau ass u.s.NuctaA:s cs:utArcaY Commissaca !j cr.m l

< LICENSEE EVENT REPORT CCNTROL SLOCIC: l 1 l 1 I I l (ptgAsg en NT OR TYad ALL Recut AED INFCAMATIONI i .@ l lo lil4l 9Il A l0 lA lC 11 l@[

WCEN344CCCg as 0 ! O I -1010yC&Asg is l 0 NwustA l0I0l l 0 l 023 l@l26 a l UGEN44 111 l Tvrt  ! I JG l l@l I Si CA f $4 I@

2 con T lolil I 8

['C% , lLW

@ l068 15 10 CCCKET 10 101313111@l11 N4uS EM 'ud 69

?! 01 11 81 1 75@l1121?!?!

EVENT OAfg 7. mgPCRT QATE 91il@ 40 EVENT DESCRIPTION AND PACSA8LE CCNSECUENCE5 h ,

e l Durino normal operation while performino surveillance testing, control b i

[ol2; I uilding ventilation system exhaust isolation damner IV-AD-31A failed.to - ,,,j isTil Iclose. This rendered the "A" control room standby filter unit innnerable I f a lsi I and a 7-day limitino condition for oneration was entered nor Tech. Spoc I la 6s i I 3.10. A.3. The redundant systom was domonstratod tn bn nnorahl o i-adia l 10 6 71 I tolv and daily thoroafter. Ono nrovinns similar nernrrnnen (son DO R1-04 I I

Io!si15). so

  • as SySTtu CAuSE COMP. valve CAUSE Coos CCc susCCCs CouncNamT CCOs susCCoe susCCCe 1oi91 l Sl Gl@ (0_j@ l 71@ l VI Al 11 VI rf pl @ l n l @ [_Z,J @

7 8 $ 10 88 82 la la is 20 REPCRT R EV' SIC N SEcutNr1AL CCCUARENCE (g pfgo (VENTYEAR A EPQRT No. COCE TYPt NO.

O"Nygr I811I ae l-l I 01 41 61 1/l iOI3I IL I L---I [0_j n

n u u 2 u v n n a v CN # NT w(T esoynt $8 PCR 8. P't. g wa yPa atA l N ACT CN lA!@lGl@

n 2 ln Z l@ lu Zl@~ l010

. v l 010.al l Y l@ ..

l 2N l@ l 2Al@ lHI1l9I5l@

a .7 l

CAusa OESCRIPTICN AND COAAECTIVE-ACTICNS h Ii io 1 l Followino repairs after a nrevious event, the damner onerator had appar I i n t i i I ently been reinstalled with a severe misalionment. This resulted in rani 1 ris2i I d bearino failure in the D0. The root cause of this and the previous eve I ii62i i nt was nroce[iural deficiency.' The Renair Procodore did not nrovide adeau l I

m I ate cuidance to oronerly alion the D0. Prnredure will be correctod. so s s s

'sTA  % PCwt

  • CTwsmSTATuS 5C R CISCCVERY CE$CAIPTION li is l L.Ej@ l O l 5 l 21@l NA I j l lBl@lSurveillanceTest
  • Cnviry CCArc r LoCAneNe,marAs @

meusse

[TT81 1 zl @e c.antesawgltuouMTCP NA Cnviry @ ll NA

.g ag l

7 8 9 to  : a.

  • etm5CNNik82*C5ysts Nyuegn tvet CISCRIPTICN 1: 1 rl 10 l010 @W@pA l i

PtmSCNNEL sNaumst5 l

NUug g a Ot$CRt# MON l

! ITT71101010 I@l NA

.. o ,,

! 'r*En'*$es'CT,'r'o'?*'*@

8 9 (J,_j@l NA l 7 8 9 to 90 NRC USE CNLY ,

is NCa.arioN c @

b [.surI.L@l NA l lllllllll1Iil? u.;

' - - ~ .. .,

8201050070 811222 -

David M. Varner ,,oy g; 319-851-5611 2, PDR ADOCK 05000331 PAREA S PDR 3

..o m

,j- .

..c. eu .

. DUANE ARNOLD ENERGY CENTER -

Iowa' Ele ~ctric Light and Power Iompany Licensee Event Report - Supplemental Data Docket No. 050-0331 Licensee Event Report Date: 12'22-81 Repor+able Occurrence No: 81-046 4  %

. Event Description During normal operation while performing surveillance testing, control building ventilation system exhaust isolation damper IV-AD-31A fa~iled to close. This rendered the "A" control room standby filter unit inoperable and a 7-day limiting condition for operation was entered per Tech. Spe'c .

3.10.A.3. The redundant system was demonstrated to be operable immediately and daily thereafter. One previous similar occurrence (See R0 81-045).

Cause Description . ,

Following repairs made a3 a result of the previous event, the damper operator had apparently been reinstalled with a severe misalignment between the damper operator' shaft Tnd the damper shaft. This resulted in accelerated bearing failure in the damper c wrator. The root cause of this and the previous event was a

' procedural defi - incy. The Rep ~ air Procedure did not provid5 adequate guidance concerning prope. alignment of the damper operator.

3

. Ccrrective Action .

~

The damper operator cylinder wills were honed and the. bearing and shaft.were

. replaced. The damper operator was-reinstalled and properly aligned to the damper shaft. The Repair Procedure will be corrected.

~

Page 1 of 1