LER 81-044/03L-0:on 811124,secondary Containment Isolation Damper on Air Ejector Room Exhaust Duct to Offgas Stack Failed to Close Completely When Operating Air Secured to Protect Damper.Cause Unknown.Investigation Continuing
ML20039D453
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 12/22/1981
From: Varner D
IES UTILITIES INC., (FORMERLY IOWA ELECTRIC LIGHT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20039D449 List:
References
LER-81-044-03L, LER-81-44-3L, NUDOCS 8201040106
Download: ML20039D453 (1)


Text

._ _ _ . . . _ _ . __ __ a. _n---_ = --w NaC Pomu ass u.s. NucLEAa RuutATcmY Commissaces e mm

  • . LICENSEE EVENT REPORT e CCNTROL SLOCiC: l i

l l 1 I I Ih (PLEAS 4 MNT On TY'd ALL REQUIREO INFORMATIONI loitll r

IIA 10uCaNsse e e l A IC CCon 11 I@l is010 l -l 010101 i4 O l 0 I l o l o @la4 l 1vCsNsa uCsNsaNwussa an l 111111@l rves ao s car sel@

l CON'T loii!

F 4 l'C"'

,c l L@l015 10 la 1013131 1 @l 11 11 21 41 81 1@l 11217 I '1 I R I 1 l@

60 Gi CoCKET Ni,ueam 6e et tvENT OAT 3 i* 71 msPomT DATE 40 EVENT QESCRIPTION ANO PRCOASLE CONSECUENCES @

io 2i I During normal operation, secondary containment isolation damper IV-AD-15 I p TTI I B on the air ejector room exhaust duct to the offaas stack failed to clo l l io t Ai i se completely. Prior to this failure, the damper had been cyclina opsn a I io;sl l nd closed repeatedly. When the operating air to the damper was secured t I t o is l l0 protect the damper, the damper failed to close comoletelv. To maintain I l a ! 71 I secondary containment inteority cer Tech. Soec. 3.7.C.1. the redundant i I t o is i I solation damoer was closed. No previous similar occurrences. I 7 s9 40 syf7EM CALs4 CAUSE Comp. VALVE CCOE CCoe sueCCCE COMPONENT CCCG sOSCCOE sueCCCE loist is 101@

. o L,Lj@ I zi2 l@ IV I A 11 I V l E I X l@ l K l@ ULj is i. i. m

,,, sSQUSNTiAL OCCURRENCE mgeCRT REVis3CN LE nf aC (VENTvtAm REPORT NC. COCE TYPt NO.

@ ,atg u I 81 11 1-1 I 0141 al I/I 1013i L-J La_1

_v n n 2 n v = , L.L.)

2 si n N AC CN P T T WQUms su8me 8CR 8. Ut WA V8 AER Iz!@lxl@

n 2<

l z l@

1s lu zl@ v l0loIo10i

<a Usil@ LEJ@

<2 LAl@

<a lHl119I5l@

u <r CAusa ossCalPTICN ANO CORRECTIVE ACTICNS h li 4 o 1 l The cause of the damper failure to close comnletelv is oresentiv unknnwn j ti!ii ! The damoer coerator was insoected and was functinnin, nrnneriv. 1 doci 1 Ii6,IIgn review has been initiated to determine the cause of the damner failur I iii2i I e and shall include the cyclino ornbloms that nrrurred prine tn this fai I Ii641llure. I s a 2 en

'sYA'E seowem ofwen status @ EsEoNv' oiscovsav cascairrich @

Li_15J LEJ@ l o I s I 9'* l@l" NA I L_A_j@l 0nerator Observation l 8.Envify C$2r NT artsAsso -ratLaAss amovNTCa aCrivery @ l toCATiCN Cr metaAss @

l1 {6I l NA l NA l

' esasCNNei. eneCsOts Nuueen Tvet cesCaiefiCN @

l 8171' '

l 0101 Ol@[JJ@l '

NA l

  • tasCN=e'L m;u'las "

Nuo.en easCm,riCN@

li ia l. I,n i n i nl@l NA

, ,, i, l

o

'fA'. '

l l

1:I9IlJj@;is'C,',T;. l NA ' " " @ l 1 . , ,.

l '"C'"

NRC USE CNLY 8201040106

12. i o i t. U@f'n*f"'

> i. '@ i i ,,,,,,,,,,ilj N AME OF *eEP ARER David M. Varner ,, a y ,; 319-851-5611 2,