l MEMORANDUM FOR: Howard Daniels, Instrumentation and Control 1
Systems Branch, DSS i
FROM:
Bill LeFave, Auxiliary Systems Branch, DSS
~
SUBJECT:
IDENTIFICATION OF SAFETY RELATED SYSTEMS AND COMPONENTS In response to your memo of September 8,1978, I have reviewed the Midlard Design for identification of (1) safety related systems iden-tified in Section 7.1, (2) safety related mechanical and electrical equipment in Table 3.11, (3) instrumentation to follow the course of an accident (Table 7.5-1).
c.
(1) Section 7.1 har identified all the safety related systems within the scope of ASB.
(2) Table 3.11 has not identified the following valves:
a.
Service Water System - Motor Operated Isolation Valves 2M0-1852, 2M0-1856
('
b.
Service Water for Reactor and Auxiliary Building Motor Operated Valves 2m0-1947.
c.
Condensate and Feedwater System IMO-3831; 2M0-3931 (steam to AFW turbine)
ISCV-3831; 2SCV-3931 (steam to AFW turbine)
ISV,IXV-3866A), B ; 2SV-3966A),B) (inside containment) j d.
Auxiliary Building HVAC (Figs. 9.4-3 through 9.4-7)
All safety related valves and dampers with designation nos. 54xx The following equipment should also be identified in Table 3.11-1.
1 a.
Instrumentation for automatic switchover of Auxiliary Feedwater Pump suction from the condensate storage tank to the service water systems.
i f
,s op
- m_ewtw
_---,--,--_--,------------------.J
... <. = -
w.
... =..
,. ~. - -.
1 N .m.
l i SEP 191978
.,f (' d Howard Daniels l
I Level transmitters in Ultimate Heat Sink pump pit used -
\\--
~
b.
}
for protection of service water pumps.
Level transmitters for CCW surge tank which are used to
- 4 s
isolate non-seismic portion of component cooling water c.
j water system.
Table.7.5-1 should also include the condensate storage tank level for instrumentation to follow the course or an accident.
]
(3) b Bill LeFave Auxiliary Systems Branch, OSS cc: