ML20035E254

From kanterella
Jump to navigation Jump to search
License Amend Request 93-03 to License NPF-86,correcting Safety Limit Curves of TS Figure 2.1-1, Reactor Core Safety Limit - Four Loops in Operation
ML20035E254
Person / Time
Site: Seabrook NextEra Energy icon.png
Issue date: 04/08/1993
From: Feigenbaum T
NORTH ATLANTIC ENERGY SERVICE CORP. (NAESCO)
To:
Shared Package
ML20035E251 List:
References
NUDOCS 9304150085
Download: ML20035E254 (2)


Text

,

i 1

l i

M North suenoox sanon umn

==zm== Aflanfic Energy Service Corporation Facility Operating License NPF-86 Docket No. 50-443

. License Amendment Request No. 93-03, Change to Technical Specification Figure 2.1-1,.

Reactor Core Safety Limit - Four Loops in Operation This License Amendment Request is submitted by North Atlantic Energy Service Corporation pursuant to 10CFR50.90. The following information is enclosed in l

support of this License Amendment Request:

i i

Introduction and Description of Proposed Changes l

.Section I i

Markup of Proposed Changes

. Section 11

. Section lli Retype of Proposed Changes Safety Evaluation of Proposed Changes

.Section IV Determination of Significant Hazards for Proposed Changes

.Section V Environmental Impact Assessment

.Section VI Section Vil Supporting Information Sworn and Subscribed to before meJhis <

[1 day of //,bh O

,1993

]//dh//d?/ded6

~

seaior vice ere if ao caier "#cie < ort'cer T

enbaum meerv #eiic,

e

1. m m _. s. a s PDR ADOCK 05000443 P

pyg

4 I

- 1 l

I.

Introduction and Description of Proposed Chance l

A.

Introduction 1

Seabrook Station Licensee Event Report (LER) 92-02-01 reported that the curves of Technical Specification Figure 2.1-1, Reactor Core Safety Limit - Four Loops in Operation, were non-conservative. The non-conservative curves were identified as a result of a North Atlantic review of the Technical Specification values provided to

)

North Atlantic by Westinghouse.

It was determined, through a comparison of Westinghouse design documents to the actual curves in Figure 2.1-1, that the curves l

in the region of 80% to 110% of rated thermal power (RTP) do not accurately represent the loci of points upon which the curves are based. For example, the 1960 4

i psia curve at 100% of RTP should provide a value of 605.0*F, while the actual curve in Figure 2.1-1 is closer to 606.5'F. There are other points in this region that can be i

determined to be non-conservative when compared to the loci of points.

l North Atlantic determined that the non-conservative curves did not constitute a safety j

hazard because plant operation in the affected area would not have occurred for two First, normal operation of the plant at power is controlled by Station l

reasons.

operating procedures which specify the normal operating band for both Reactor Coolant System (RCS) temperature and pressure. The normal operating pressure is 2235 psig and the Station procedures require that the RCS pressure be maintained l

between 2205 and 2265 psig. The RCS temperature is maintained within c4'F of the Tavg program and the normal RCS temperature per the Ty program at 100% of RTP is 587'F. The second reason is related to the Reactor Protection System (RPS)

]

reactor trips which are designed to prevent the safety limits from being challenged.

f j

These RPS trips are the Overtemperature AT trip, Overpower AT trip and the Power l

Range Neutron Flux High trip. These RPS trips are developed using the criteria of l

Technical Specification 2.2.1, Reactor Trip System Instrumentation Setpoints, and do l

not utilize the values of the curves in Figure 2.1-1. These RPS trips have not been challenged or exceeded at Seabrook Station and therefore the safety limit as provided in Figure 2.1-1 has not been challenged.

j l

l 1

This condition was reported to the NRC in Licensee Event Report 92-02-01. One of

]

the corrective actions specified in LER 92-02-01 was to revise Technical Specification Figure 2.1-1 to include curves which accurately reflect the loci of points upon which j

they are based. This submittal addresses that corrective action.

B.

Description of Proposed Change The proposed change consists solely of revising Technical Specification Figure 2.1-1 to provide curves which accurately reflect the loci of points upon which the curves are based and is consistent with the Westinghouse design calculations. The revised 3

curves are provided in Section II as a marked Figure 2.1-1 and in Section III-as a retyped Figure. The loci of points used to generate the curves are provided in Section VIII.

1

-m w,-

.r,2..,.

1-

---.t,.-

,-n--

-w,.s.-

y p w,9e v.

- -, i