,p'# "

UNITED STATES

/

7 %

NUCLEAR REGULATORY COMMISSION N

f OFFICE oF INVEST 40 ATioNS FIELD OFFICE, REoloN tv
  • "I E d $ $.[t ES $ N
  • June 27, 1990 MEMORANDUM FOR:

Dennis utchfield, NRR FROM:

Driskill, Director Office of Investigations Field Office, RIV

SUBJECT:

01 INTERVIEW 0F JOHN CORDER On Marr' '8,1990, John Corder, a former Bechtel Corporation employee, who worked,

che Houston Lighting and Power Company (HL&P) South Texer Project (STP), met with the NRC staff personnel and NRC Office of Investiptions (01)

Investigator Virginia Van Cleave to discuss safety concerns involving alleged wrongdoing, which he [ Corder) believes to exist at sip. Corder was represented during this inttrview with Attorney Billie Garde.

Prior to the interview with Investigator Van Cleave, Corder related to NRC staff members his concerns which were technical in nature.

Prior to subject interview, Investigator Van Cleave reviewed 01:RIV Report of Investigation 4-86-016 which related to previous allegations of wrongdoing related to the alleged discriminatory termination of Corder by Bechtel. This investigation did _not substantiate Corder's claims.

Investigator Van Cleave reported to me that during the March 28, 1990, meeting, Corder and Garde recited numerous accounts of matters pertaining to topics such as waste, mismanagement, and poor construction practices.

Investigator Van Cleave advised neither Corder or Garde presented any allegations which OI traditionally interprets as wrongdoing or matters necessitating 01 investigation.

In. view of the above determination and NRC technical staff presence at this interview, 01:RIV has not prepared any formal record of the concerns cited by Corder.

Should you have any further questions concerning this matter please contact me at(FTS)728-8110.