ML19036A969
| ML19036A969 | |
| Person / Time | |
|---|---|
| Site: | NuScale |
| Issue date: | 02/05/2019 |
| From: | Rad Z NuScale |
| To: | Document Control Desk, Office of New Reactors |
| References | |
| LO-0119-64396 | |
| Download: ML19036A969 (53) | |
Text
LO-0119-64396 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com Docket No.52-048 February 5, 2019 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738
SUBJECT:
NuScale Power, LLC Submittal of Changes to Final Safety Analysis Report, Section 14.2, Initial Plant Test Program and Section 14.3, Certified Design Material and Inspections, Test, Analyses, and Acceptance Criteria
REFERENCES:
Letter from NuScale Power, LLC to Nuclear Regulatory Commission, NuScale Power, LLC Submittal of the NuScale Standard Plant Design Certification Application, Revision 2, dated October 30, 2018 (ML18311A006)
During several public teleconferences with various NRC Staff, NuScale Power, LLC (NuScale) discussed potential updates to Final Safety Analysis Report (FSAR), Section 14.2, Initial Plant Test Program and Section 14.3, Certified Design Material and Inspections, Test, Analyses, and Acceptance Criteria. As a result of this discussion, NuScale changed Sections 14.2 and 14.3. The Enclosure to this letter provides a mark-up of the FSAR pages incorporating revisions to Sections 14.2 and 14.3, in redline/strikeout format. NuScale will include this change as part of a future revision to the NuScale Design Certification Application.
Also included in an attachment are NuScales responses to the initial test program questions received by the NRC.
This letter makes no regulatory commitments or revisions to any existing regulatory commitments.
If you have any questions, please feel free to contact Carrie Fosaaen at 541-452-7126 or at cfosaaen@nuscalepower.com.
Sincerely, Zackary W. Rad Director, Regulatory Affairs NuScale Power, LLC Distribution: Samuel Lee, NRC, OWFN-8H12 Gregory Cranston, NRC, OWFN-8H12 Cayetano Santos, NRC, OWFN-8H12
Attachment:
NuScale Responses to ITP Questions
Enclosure:
Changes to NuScale Final Safety Analysis Report Sections 14.2, Initial Plant Test Program and Section 14.3, Certified Design Material and Inspections, Test, Analyses, and Acceptance Criteria
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 1 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com NRC Question 1.0:
Pool Surge Control System Test #4: The system function that states the PSCS supports the UHS by providing surge control for UHS operations, is not clearly tested in Test #4-1 as indicated. Explain or correct the abstract to reflect the appropriate test.
NuScale Response:
Table 14.2-4, Pool Surge Control System Test #4, System Level Test #4-1 has been revised as follows:
The test method will be revised to support two new acceptance criteria.
Acceptance criteria will be added to verify inventory addition to the PSCS tank with a PSCS pump running.
Acceptance criteria will be added to verify inventory addition to the dry dock with the PSCS tank main discharge line isolation valve open.
NRC Question 2.0:
Auxiliary Boiler System Test #9: No System Level test is indicated. Explain or correct the abstract to reflect the appropriate test.
NuScale Response:
The auxiliary boiler system functions are inventoried in Table 14.2-9, Auxiliary Boiler System Test # 9. For each function listed, the corresponding entry in the Function Verified by Test #
column provides the location of a system level test that verifies the ABS function. Because all ABS system functions listed in Table 14.2-9 are tested in other systems system level tests (for example, CPS Test #30-1), there are no system level tests for the ABS.
NRC Question 2.1:
Auxiliary Boiler System Test #9: The test reference under the System Functions do not clearly indicate how the Functions are verified for the high pressure (HP) and low pressure (LP) sides of the auxiliary boiler system (ABS). Update the abstract accordingly.
NuScale Response:
Table 14.2-9, Auxiliary Boiler System Test # 9, lists Sections 10.4.10 and 11.5.2.2.14 as locations for descriptions of the ABS. Section 10.4.10 provides a description, including whether the function is a high pressure or low pressure function, for each of the system functions inventoried in Table 14.2-9. Repeating this information in the test abstract is unnecessary.
NRC Question 2.2:
Auxiliary Boiler System Test #9: The function of providing steam at a rated pressure from the HP to LP is not clearly indicated. Update the abstract accordingly.
NuScale Response:
The ability of the high pressure portion of the ABS to supply steam to the low pressure portion of the ABS is demonstrated via overlap testing. Functionality of the high pressure portion of the ABS is demonstrated through TG Test #33-1. Functionality of the low pressure portion of the ABS is demonstrated through CAR Test #32-1. As discussed in Section 14.2.3.4, Generic Component Testing, control valves are set up and tested as part of the generic component
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 2 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com testing that must be completed as a prerequisite to the performance of preoperational testing.
The combination of testing the high pressure systems ability to develop rated pressure, the pressure control valves ability to reduce pressure to the appropriate pressure, and the low pressure systems ability to deliver the steam to loads fully demonstrate this capability.
NRC Question 2.3:
Auxiliary Boiler System Test #9: It is not clearly indicated how the system limits (simultaneously heat up the reactor coolant system, provide gland seal and condenser sparger steam) are going to be evaluated if the referenced tests are not going to be performed simultaneously. Explain or update the abstract accordingly.
NuScale Response:
There is not a requirement to ensure support systems can perform all of their functions simultaneously. For example, preoperational testing of electrical buses does not require all loads supplied power by the bus to be simultaneously operated to demonstrate the ability of the bus to provide sufficient power under maximum load. Instead, the design is credited with sizing the bus appropriately for the load it will supply, while the ability to provide power to the individual loads is tested.
However, during hot functional testing the ABS will provide steam to the module heating system, gland seals, and condenser sparging simultaneously, as can be seen in System Level Tests
- 32-1 and #33-1. This simultaneous functionality will also be demonstrated during startup testing.
NRC Question 2.4:
Test #33-1: The last sentence of the test method is unclear. Clarify if this was intended to make reference to ABS instead of FWS. This section requires to place the ABS HP in auto to heat the MHS heat exchanger to the highest temperature achievable. What is this temperature stated in the FSAR? Update the test abstract to reflect the appropriate location where the information can be found.
NuScale Response:
In Table 14.2-33 Turbine Generator System Test #33, System Level Test #33-1, the last sentence of the test method, Align the FWS to cool the gland seal steam desuperheater, is correct.
At this phase of design, it is unknown how high of an RCS temperature will be achieved using the MHS. Accordingly, the value is not stated in the FSAR. However, the low end temperature is bounded by the acceptance criteria of RCS temperature is sufficient to obtain criticality.
NRC Question 2.5:
Test #32-1: This is the test tacking credit to verify the gland seal is provided steam from the ABS LP. Under the Acceptance Criteria (iii) need to verify pressure of the gland seal. How is this related to the ABS LP system level function verification?
NuScale Response:
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 3 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com The auxiliary boiler system is a support system with the purpose of supplying steam at pressures and flows that allow the supported systems to perform specific functions. As such, parameters in the supported system typically provide more meaningful acceptance criteria when testing the ABS.
Test #32-1 acceptance criterion (iii) verifies Table 14.2-9, Auxiliary Boiler System Test # 9, System Function 3, The ABS supports the turbine generator by supplying gland seal steam. To verify the low pressure portion of the auxiliary boiler system is supplying adequate steam to the gland seals, gland seal pressure is verified while there is a vacuum in the condenser and gland seal steam is sealing the turbine seals.
NRC Question 2.6:
Test #32-1: Test method (ii) requires opening the feedwater spare isolation valve to provide steam sparging to MC. Is this sentence correct and how this related to the ABS LP system level function verification?
NuScale Response:
The main condenser is part of the feedwater system, thus feedwater valves are used to isolate ABS sparging steam from the main condenser. Test method (ii) is correct as written.
The function being verified is, The auxiliary boiler supports the FWS by supplying steam to the condenser for sparging when necessary. With the sparging steam isolation valves open, sparging steam flow is verified in accordance with acceptance criteria (ii).
NRC Question 2.7:
Test #30-1: Acceptance criterion (iv) makes reference to a design temperature but is not clearly indicated. How this is related to the ABS LP system level function verification?
NuScale Response:
At this phase of the design, the condensate polishing system hot water heater design outlet temperature is not known. This value will be populated during the development of the detailed test procedures.
The auxiliary boiler system is a support system with the purpose of supplying steam at pressures and flows that allow the supported systems to perform specific functions. As such, parameters in the supported system typically provide more meaningful acceptance criteria when testing the ABS.
Table 14.2-30, Condensate Polishing System Test # 30, System Level Test #30-1, Acceptance Criterion (iv) is verifying Table 14.2-9, Auxiliary Boiler System Test # 9, System Function 1, which states, The auxiliary boiler supports the condensate polishing system (CPS) by supplying steam for resin regeneration. The purpose of the steam supplied by the ABS to the CPS is to heat the water in the CPS hot water heater. Therefore, the best parameter for verifying the adequacy of the steam supply from the ABS is the CPS hot water heater outlet temperature.
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 4 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com NRC Question 3.0:
Fire Protection Systems Test #25: In FSAR Section 9.5.1, Fire Protection Program, the applicant states that various portions of the fire protection system conforms to or is in accordance with NFPA standards. For example, the applicant states that:
Fire pump installations conform to NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection.
And Automatic sprinkler systems are installed in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems.
The staff reviewed FSAR Section 14.2, Initial Plant Test Program, Table 14.2-25, Fire Protection System Test #25, and found no indication that the initial testing for the fire protection system will be in accordance with the appropriate NFPA standard, as mentioned in FSAR Section 9.5.1.
The applicant is requested to state in Table 14.2-25 that the initial acceptance test for the fire protection system will be as described in the appropriate NFPA standard.
NuScale Response:
Table 14.2-25, Fire Protection System Test # 25, and Table 14.2-26, Fire Detection System Test # 26, have been revised to include a statement that the preoperational test is conducted in accordance with the applicable criteria in codes and standards listed in Table 9.5.1-1. NFPA 13, NFPA 20, NFPA 70, and NFPA 72 are listed as applicable codes, standards, and regulatory guidance in Table 9.5.1-1.
NRC Question 3.1:
Additionally, as Fire Detection Test #26 refers to Test #25: In FSAR Section 9.5.1.2.6, Fire Protection Design Features, the applicant stated that Fire detection and alarm systems comply with the requirements of Class A systems, as defined in NFPA 72, "National Fire Alarm Code," and Class I circuits, as defined in NFPA 70, "National Electrical Code."
The staff reviewed FSAR Section 14.2, Initial Plant Test Program, Table 14.2-26, Fire Detection Test #26, and noted that there are no initial test details unlike what was indicated in FSAR Section 9.5.1.2.6.
The applicant is requested to state in Table 14.2-26 that the initial acceptance test for the fire detection and alarm system will be performed as described in NFPA 70 and NFPA 72, as indicated in FSAR Section 9.5.1.2.6.
NuScale Response:
Table 14.2-25, Fire Protection System Test # 25, and Table 14.2-26, Fire Detection System Test # 26, have been revised to include a statement that the preoperational test is conducted in accordance with the applicable criteria in codes and standards listed in Table 9.5.1-1. NFPA
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 5 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com 13, NFPA 20, NFPA 70, and NFPA 72 are listed as applicable codes, standards, and regulatory guidance in Table 9.5.1-1.
NRC Question 4.0:
Turbine Generator Test #33: Regarding component level test viii, the acceptance criteria states that the turbine stop valve and control valve close upon receiving simulated overspeed trip signals. Assuming the test is performed to demonstrate the functional performance of the valves, the acceptance criteria should be based on valve closure in the specified allowable valve closure time since the maximum turbine overspeed reached will be dependent on the valve closure time.
NuScale Response:
Table 14.2-33, Turbine Generator Test #33, component level test (viii) has been revised to include direction in the Test Method to record the stroke times of the turbine stop valve and turbine control valves. Acceptance Criteria was added to verify each valves stroke time is within design limits.
NRC Question 4.1:
Additionally, it was noted that the test did not include closure of the reheat stop valves and intercept valves which also typically close when a turbine trip is initiated. Is there a reason for the omitting this function?
NuScale Response:
The turbine generator system does not include a moisture separator reheater, and therefore does not have reheat stop valves or intercept valves.
NRC Question 4.2:
Regarding the system-level test, is there a test to demonstrate the ability to manually trip the turbine locally or from the main control room?
NuScale Response:
Table 14.2-33, Turbine Generator Test #33, has been revised to include a new component level test to verify the turbine can be manually tripped from the main control room.
NRC Question 5.0:
Chemical and Volume Control System Test #38: The acceptance criteria in the test indicates several setpoints and specifications but does not provide an appropriate reference for those values. Update the acceptance criteria to reference where the information can be found (i.e.,
FSAR section, Technical Specifications, etc.).
NuScale Response:
Tests #38-1, #38-2, and #38-3 reference operator control setpoints, rather than design setpoints, for pressurizer level, pressurizer pressure, and boron concentration. The tests are conducted by changing the operator control setpoint to a desired value and verifying the CVCS
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 6 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com automatically responds to establish and maintain the parameter at the new setpoint. The setpoints used during the tests will be determined when the detailed test procedures are developed, and are not required for the test abstracts.
NRC Question 6.0:
Control Rod Drive System Flow-Induced Vibration Test #44: The Control Rod Drive System (CRDS) Flow-Induced Vibration Test indicates that validation testing is performed during factory testing and that there are no preoperational tests for the CRDS. Typically design certification applicants have performed vibration testing during power ascension. Explain why this is not being done or update the abstract accordingly.
NuScale Response:
Vibration testing will be performed in accordance with TR-0716-50439-P, NuScale Comprehensive Vibration Assessment Program Technical Report, as referenced in Table 14.2-44, Control Rod Drive System Flow-Induced Vibration Test # 44. Additionally, Table 5-1 of the Technical Report describes the CRDS visual examinations required as part of startup testing and provides acceptance criteria for those examinations. This requirement is stipulated in Table 14.2-108, NuScale Power Module Vibration Test # 108.
NRC Question 7.0:
Reactor Vessel Internals Flow-Induced Vibration Test #45: The Reactor Vessel Internals (RVI)
Flow-Induced Vibration Test indicates that validation testing is performed during factory testing and that there are no preoperational tests for the RVI. Typically design certification applicants have performed vibration testing during power ascension. Explain why this is not being done or update the abstract accordingly.
NuScale Response:
Vibration testing will be performed in accordance with TR-0716-50439-P, NuScale Comprehensive Vibration Assessment Program Technical Report, as referenced in Table 14.2-45, Reactor Vessel Internals Flow-Induced Vibration Test # 45. Additionally, Table 5-1 of the Technical Report describes the RVI visual examinations required as part of startup testing and provides acceptance criteria for those examinations. This requirement is stipulated in Table 14.2-108, NuScale Power Module Vibration Test # 108.
NRC Question 8.0:
Emergency Core Cooling System Test #47: Articulate the reason for omitting a system-level ECCS test.
NuScale Response:
Table 14.2-47, Emergency Core Cooling System Test # 47, has been revised to include a system level test of ECCS. The test is performed during hot functional conditions (normal operating pressure and the highest RCS temperature achievable using the MHS), and includes acceptance criteria to verify collapsed liquid level remains above the top of the core and CNV temperature and pressure remain within design limits identified in Table 6.2-1 during the test.
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 7 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com NRC Question 9.0:
Decay Heat Removal System Test #48: NuScale submitted an RAI response regarding the DHRS. Which version of Draft Revision 3, Test #48 should the staff consider valid?
NuScale Response:
The version of Table 14.2-48, Decay Heat Removal System Test # 48, provided in the RAI 9570 response is the valid version.
NRC Question 10.0:
Plant Lighting System Test #60: Test Acceptance Criteria (ii)a does not address the MCR safety display information panel. Instead, it makes reference to the auxiliary panel in the RSS. This is not consistent with the test objective nor ITAAC 03.08.02. Explain or correct the test abstract accordingly.
NuScale Response:
Table 14.2-60, Plant Lighting System Test # 60, has been revised to change RSS to MCR.
NRC Question 10.1:
The Acceptance Criteria makes reference to 1 foot candle in the areas outside the MCR and RSS and ITACC 03.08.03. The 1 foot candle is not consistent with table 9.5.3-1. Additionally, the value of 1 foot-candle in not justified nor a basis provided for the value. The NRC staff issued an RAI as this value is not consistent with NUREG -0700.
NuScale Response:
The Design Commitment associated with NEI 15-02 standardized ITAAC E24, NuScale Tier 1 ITAAC 03.08.03, and the associated preoperational test (iii) found in Tier 2 Table 14.2-60, Plant Lighting System Test # 60, are based on the following RG 1.189 Section 4.1.6.2, Postfire Safe Shutdown, guidance:
Fixed, self-contained lighting consisting of fluorescent or sealed-beam units with individual 8-hour minimum battery power supplies should be provided in areas needed for operation of safe-shutdown equipment and for access and egress routes to these areas.
The associated illumination requirements are found in NFPA 804 Section 8.6.4, and are outside of the guidance found in NUREG-0700. NFPA 804 states:
The floor of the means of egress and the safe shutdown operations shall be illuminated to values of not less than 1 footcandle measured at the floor and at safe shutdown equipment at all points, including the following:
(1) Angles (2) Intersections of corridors (3) Passageways (4) Stairways (5) Landings of stairways (6) Exit doors
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 8 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com (7) Safe shutdown equipment (8) Access and egress routes to safe shutdown equipment This represents guidance that is outside and separate from the guidance provided in NUREG-0700, and does not conflict with any PLS design feature described in Section 9.5.3.
Furthermore, the entry in Table 9.5.3-1 that was thought to be in conflict with the ITAAC and preoperational test acceptance criteria had been deleted from the table.
Table 14.2-60, Plant Lighting System Test #60, has been revised to add a note in the prerequisite section to point to the requirements in NFPA 804.
NRC Question 10.2:
RAI 09.03.11 talks about the Emergency Lighting level in other areas. Table 9.5.3-1, Plant Illumination Levels, made reference that for other lighting in the plant the level was 2 foot-candle. In the RAI the staff requested clarification because the 2 foot-candle level was not clear where it came from. In table 14.2-60 item (5) requests to evaluate the lighting level around the Reactor Building. Then the Acceptance Criterion for test objective item (iii), states that the:
areas are illuminated at least with one foot-candle. Under section 9.5.3 of the FSAR these areas have a minimum level of 2 foot-candle and not one foot-candle. As part of the response to the RAI NuScale agreed to remove the requirement of 2 foot-candle and committed to meet the requirements in NUREG 0700. Also, the text and the reference related to the 2 foot-candle requirement has been removed from Section 9.5.3. Section 9.5.3 does not make reference to NFPA 0804, which is what NuScale proposed to be added to Table 14.2-60 to justify the value of one foot-candle under the Acceptance Criterion to item (iii). The reference in table 14.2-60 and ITAAC 03.08.03 to NFPA-0804 contradict Section 9.5.3 as revised. In the latest proposal to Section 9.5.3 NuScale commits to NUREG 0700. Why is Table 14.2-60 not in alignment with Section 9.5.3?
NuScale Response:
Section 9.5.3 will be updated to reference NFPA-804 requirement via RAI 9311, Question 09.05.03-S2S.
NRC Question 11.0:
- 63-2, #63-5, and #63-9: These tests indicate not used. At the previous public meeting on November 28 it was discussed that justification/evidence should be provided to clarify removal of the test.
NuScale Response:
The following provides a summary of the changes made to Table 14.2-63: Module Protection System Test # 63:
System functions were identified that are tested, but were not specifically inventoried. As a result, these functions were added to the MPS Test #63 test abstract system functions, and linked to their associated tests through the Functions Verified by Test # column.
For example, function 25 (The CVCS supports the RCS by providing primary coolant makeup in beyond design basis events) and function 26 (The CFDS supports the RCS by providing borated coolant inventory for the removal of core heat during a beyond
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 9 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com design basis accident) were added because both functions will be demonstrated by Test
- 63-11.
All MPS factory acceptance testing (FAT) and site acceptance testing (SAT) will be completed prior to turnover of the system for preoperational testing. As a result, all MPS logic testing and MPS component testing will be performed during FAT and SAT, and are not required to be re-performed as part of preoperational testing. MPS system level tests were impacted as follows:
o System Level Test #63-2: This test was solely logic testing that will be conducted during FAT/SAT and was deleted in its entirety from Test #63.
o System Level Test #63-3: This test previously contained three objectives. The first two objectives are tested in FAT/SAT, and were deleted from the test. The third objective involves verification of MCR alarms and was retained and revised, but relocated to System Level Test #63-10, Test Objectives i. and ii. Additionally, a new test for stroke time verification of the ECCS RVVs and RRVs was identified, and rather than creating a system level test number, System Level Test #63-3 was repurposed for the stroke time test.
o System Level Test #63-4: This test previously contained two objectives for testing MPS logic. Both are tested as part of FAT/SAT, and were deleted from the test. Additionally, a new test for stroke time verification of the DHRS actuation valves was identified, and rather than creating a system level test number, System Level Test #63-4 was repurposed for the stroke time test.
o System Level Test #63-5: This test previously contained two objectives for testing the MPS reactor trip function. The switches used to manually initiate a reactor trip and the reactor trip breakers used to test objective i. are part of the MPS. Test objective ii. tests logic and the reactor trip breakers. Both objectives are tested in their entirety during FAT/SAT. This test was deleted.
o System Level Test #63-6: This test previously contained three objectives. The third objective was exclusively logic testing that will be conducted during FAT/SAT, and the objective was deleted from Test #63.
o System Level Test #63-9: This test is performed as part of FAT/SAT and was deleted in its entirety from Test #63.
o System Level Test #63-10: This test previously contained two objectives. The first objective is tested during FAT/SAT and was replaced by the third objective from System Level Test #63-3 (see description of System Level Test #63-3 above). The previous objective ii on System Level Test #63-10 was retained and moved to Test Objective iii.
o System Level Test #63-11: In previous discussion, NRC Staff indicated that it was not clear this test intended to test both divisions and trains of equipment that could be used to perform NuScales IHAs. The test was significantly revised to provide the requested clarification.
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 10 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com NRC Question 11.1:
- 63-6: Several items have been identified as having a terminology mismatch. Explain or correct abstract accordingly:
Table 7.1-4 states high narrow range containment pressure; is it narrow range containment pressure in table 7.1-2?
Table 7.1-4 states low low pressure level; is it pressurizer pressure in table 7.1-2?
Table 7.1-4 states low AV voltage to battery charger; is it EDSS bus voltage in table 7.1-2?
Table 7.1-4 states high containment water level; is it containment water level on table 7.1-2? One table is in percent while the other is in inches of elevation of water.
Table 7.1-4 states low ELVS voltage 24-hour timer; is it ELVS voltage in table 7.1-2?
Analytical limit is in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> while the other table requires volts.
More examples may be indicated in tables 7.1-4 and 7.1-2 NuScale Response:
Table 7.1-2, Variables Monitored by Module Protection System, provides a list of the variables monitored by the MPS and the range over which those variable are monitored. Table 7.1-4, Engineered Safety Feature Actuation System Functions, describes the state of the variables monitored by MPS that would result in an ESFAS actuation. For example, Table 7.1-2 lists Main Steam Pressure (DHR Inlet Pressure) as a variable monitored by MPS and lists a range of 0 to 1200 psia, while Table 7.1-4 lists Low Main Steam Pressure, Low Low Main Steam Pressure, and High Main Steam Pressure with analytical limits of 300 psia, 100 psia, and 800 psia, respectively, as causing a DHRS actuation.
The two tables are providing related but different information, and are not in conflict.
NRC Question 12.0:
Safety Display and Indication System Test #66: The Prerequisites do not require or state that, A complete staging and testing of system hardware and software configurations will be conducted. This factory acceptance testing [FAT] will be conducted in accordance with a written test procedure for testing the software and hardware of the SDIS prior to installation in the plant.
Following installation, site acceptance testing [SAT] shall be completed in accordance with developed procedures to ensure the SDIS is installed and fully functional as designed. This testing must be completed and approved prior to performing preoperational testing. As stated in part, in Section 7.2.1, Quality of the FSAR, Software development and QA controls are applied to the following safety-related and nonsafety-related I&C systems: MPS, SDIS, ICIS, PPS, MCS, PCS, RMS, general I&C SSCs that contain embedded digital devices. It would appear NuScale is proposing to change the QA controls originally specified for the SDIS when compared to the testing of other I&C equipment for the ITP.
NuScale Response:
Table 14.2-66, Safety Display and Indication System Test #66, has been revised to add a prerequisite for factory and site acceptance testing.
Update: In a public meeting held 12/18/18, NRC Staff stated that if the statement The testing and installation of digital I&C systems includes factory acceptance testing and site acceptance testing which is completed as part of construction and installation tests performed prior to
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 11 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com preoperational tests in Section 14.2.1.1 was intended to be a generic prerequisite statement, it is confusing to have a factory and site acceptance testing prerequisite statement in the individual test abstracts. As a result, Table 14.2-66, Safety Display and Indication System Test
- 66, and Table 14.2-63, Module Protection System Test #63, have been revised to remove the factory and site acceptance testing prerequisite statements. Additionally, the above statement from Section 14.2.1.1 was revised as follows:
a reference to FSAR Section 7.2.1 was added wording to clarify factory and site acceptance testing are prerequisite to preoperational testing was added The statement now reads as follows:
The testing and installation of digital I&C systems is described in FSAR Section 7.2.1, and includes factory acceptance testing and site acceptance testing which is completed as part of construction and installation tests performed prior to, and as a prerequisite of, preoperational tests.
NRC Question 13.0:
Steam Generator Flow-Induced Vibration Test #72: The Steam Generator (SG) Flow-Induced Vibration Test indicates that validation testing is performed at test facilities as separate effects tests and that there are no preoperational tests for the SG. Typically design certification applicants have performed vibration testing during power ascension. Explain why this is not being done or update the abstract accordingly.
NuScale Response:
Table 14.2-72 Steam Generator Flow-Induced Vibration Test # 72, is being performed at a test facility to provide higher quality and quantity of testing data. The two phenomena of most concern occur at flow rates higher than our licensing basis allows, so performing in a test facility allows us to test at flow rates in excess of our licensing basis to observe the onset of the phenomena and thus quantify our safety margins.
NRC Question 14.0:
Initial Fuel Load Test (Test #76): Test 76 should include a prerequisite on NMS neutron count rate. RG 1.68, Section A-3, states that, A neutron count rate of at least 1/2 counts per second should register on the startup channels before startup begins, and the signal to noise ratio should be known to be greater than 2. This is to ensure accurate readings over background noise.
NuScale Response:
The RG 1.68 statement referenced in the question comes from Section A-3, Initial Criticality, while Table 14.2-76, Initial Fuel Load Test # 76, is applicable to initial fuel loading. However, RG 1.68 Section C-2 provides prerequisite guidance for fuel loading. While this guidance is specifically intended for inclusion in detailed fuel loading procedures, Table 14.2-76 has been revised to add the prerequisite The nuclear instrumentation system is calibrated and operable.
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 12 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com NRC Question 15.0:
Control Rod Assembly Ambient Temperature Full-Height Drop Time Test #81A: The Prerequisites states that, The RCS is at ambient temperature. The test is expected to be conducted prior to heat-up. However, Test #81 with the RCS at hot zero power (RCS at normal operating pressure and RCS temperature at the maximum temperature obtainable when heated only by the MHS). It would seem that in the sequence of testing, this particular test is out of order with what the status of the RCS temperature would be. Also, it may be prudent to define what is meant by ambient temperature to ensure the test is conducted at the proper temperature.
NuScale Response:
Table 14.2-81A, Control Rod Assembly Ambient Temperature Full-Height Drop Time Test #81A, has been revised to state cold temperature conditions, as used in RG 1.68, vice ambient temperature.
NRC Question 16.0:
Initial Criticality Test (Test #83): Test 83 should include a prerequisite on NMS neutron count rate. RG 1.68, Section A-3, states that, A neutron count rate of at least 1/2 counts per second should register on the startup channels before startup begins, and the signal to noise ratio should be known to be greater than 2.
The Prerequisites do not state to verify that the status of the control rods in the core are at the all rods in position prior to initiation of the test. Clarify if the intent is to start initial criticality with verifying all rods are in the core.
NuScale Response:
Table 14.2-83, Initial Criticality Test # 83, has been revised to add the prerequisite, A neutron count rate of at least 1/2 counts per second registers on the startup channels, and the signal to noise ratio is greater than 2.
Prerequisite (vii) requires all rods to be fully inserted prior to commencing the test.
NRC Question 17.0:
Neutron Monitoring System Power Range Flux Calibration Test (Test #92): Is the intent to calibrate the excore instrumentation with the incore instrumentation? Typically calibration is done via a heat balance.
NuScale Response:
Table 14.2-92, Neutron Monitoring System Power Range Flux Calibration Test # 92, Test Method (i) has been revised to require heat balance data to be recorded during the test. The detailed method for calibrating the excore instrumentation using the recorded data will be described in the detailed test procedure.
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 13 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com NRC Question 18.0:
Reactor Coolant System Flow Calibration Test #94: The Prerequisites do not state how the power measurement will be achieved. For instance, if power measurement will be by the NMS flux, clarify that the MNS flux calibration is a prerequisite.
NuScale Response:
Table 14.2-94, Reactor Coolant System Flow Calibration Test # 94, has been revised to add a prerequisite for NMS calibration.
NRC Question 19.0:
Step Change in Load Demand Test #101: Clarify how the dynamic response of Test #101 is evaluated. Update the abstract accordingly.
NuScale Response:
In table 14.2-101, Step Change in Load Demand Test # 101, dynamic response is evaluated based on parameter maintaining within design limits. The controllers will be programmed to maintain system parameters whether it is a small or large change in power.
NRC Question 19.1:
The stresses generated under Test #101 are more significant than the stresses generated under Test #100. If Test #100 include piping vibration testing, explain why Test #101 does not include vibration testing?
NuScale Response:
Piping vibration is evaluated via two methods; observation for indications of water hammer during transient conditions and steady-state piping vibration measurements. Because the steady-state conditions are identical for Test #100 and Test #101, either test may include the vibration measurements, while it is appropriate to include observations for water hammer in both tests. Table 14.2-100, Ramp Change in Load Demand Test # 100, acceptance criterion (viii) has been revised to provide clarification.
NRC Question 19.2:
In order to perform Test #101, the expectation is that power will be reduced below 25% or this test will be performed after a reactor trip. Provide a prerequisite clarifying this information.
NuScale Response:
The sequence of power ascension testing will be determined as required by Table 14.2-90, Power-Ascension Test # 90. This makes a prerequisite unnecessary.
NRC Question 20.0:
Island Mode tests: Specify service unit generator in test #105 and service unit turbine generator in test #106. Explain the difference and what is meant by the two terms.
NuScale Response:
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 14 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com Island Mode Tests #105 and #106 both reference Section 8.3.1.1.1, which states, The service unit is a pre-selected unit (a single NPM and turbine generator combination) that provides power to plant house loads upon automatic transfer to island mode. The service unit turbine generator is therefore a subset of the service unit.
NRC Question 21.0:
Remote Shutdown Workstation Test (Test #107): The test was removed without justification.
Explain.
NuScale Response:
A review of the test objectives of table 14.2-107, Remote Shutdown Workstation Test #107, revealed that all testing was redundant to existing tests.
The first test objective, Verify the NPM safety-related controls can be disabled at the remote shutdown station is performed during factory and site acceptance testing as all components are part of MPS.
The second test objective states, Verify the NPM nonsafety-related controls are functional at the remote shutdown station. From RP-0316-17619, Human-System Interface Design Results Summary Report Section 4.6.3:
The suite of HSI display pages used to provide the alarms, indications, procedures and touch controls to the MCR are available in the RSS. The operators will be provided a set of MCS and PCS displays identical to the MCS and PCS displays in the MCR which include the process variables necessary to monitor safe shutdown of multiple modules via the navigation schema designed by NuScale.
Controls at the RSS are redundant to the controls in the MCR, and MCS and PCS controls are tested throughout factory acceptance testing, site acceptance testing, and preoperational testing; therefore, testing the controls at the RSS is redundant testing.
The third test objective states, Verify each fully withdrawn CRA satisfies the CRA drop time acceptance criteria with the reactor operating at 10 - 20 percent reactor thermal power. CRA drop times are obtained in Tests #81, #81A, and #104. This test objective was created to address Regulatory Guide 1.68 recommendation to measure CRA drop when reactor trips are conducted as part of testing. Since CRA drop times are already tested elsewhere and with the rest of Test #107 removed, this objective is no longer necessary.
Table 14.2-61, Module Control System Test #61, and Table 14.2-62, Plant Control System Test #62, have been revised to include a discussion regarding the verification of the ability to activate MCS and PCS displays and controls during site acceptance testing. Additionally, although not part of the MCS or PCS, a description of the verification of the ability to isolate the safety-related MCR manual switches from the RSS during MPS factory and site acceptance testing will be added to the aforementioned tables for clarity and completeness.
NRC Question 22.0:
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 15 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com 100 Percent Load Rejection Test (Test #103): The acceptance criteria previously contained information regarding the turbine generator bypass valve. Does one of the control systems indicated include the turbine bypass system? Explain the removal.
NuScale Response:
The previous criterion referenced stated, The turbine generator bypass valve opens and modulates steam flow to the condenser to maintain steam generator pressure. The key attribute of this acceptance criterion was the ability to maintain steam generator pressure. This was incorporated into the new acceptance criterion which verifies The plant automatic control systems, with no manual intervention, maintain the following parameters within design limits during and following the transient: f. SG pressure. However, to ensure clarity, Table 14.2-103, 100 Percent Load Rejection Test # 103, has been revised to return the above statement regarding bypass valve operation to the acceptance criteria.
NRC Question 22.1:
The acceptance criteria requires a check for water hammer indications. Should this test consider piping vibration test as a part of the dynamic response evaluation of the plant?
NuScale Response:
The NuScale design includes 100% turbine bypass capability on a load reject. As a result, this test has minimal impact on the piping within the scope of vibration testing. For this reason, vibration testing was not included as part of the dynamic response evaluation.
NRC Question 23.0:
Table 14.2-102, test objective (ii), states that the dynamic response of the plant for the loss of the high pressure feedwater heater will be assessed. Under the Acceptance Criteria section is not clear how this will be evaluated to meet the requirements of the test objective (ii). Please provide clarification NuScale Response:
Table 14.2-102, Loss of Feedwater Heater Test # 102, Acceptance Criterion (iv) states, The plant automatic control systems, with no manual intervention, maintain the following parameters within design limits during and following the transient, and provides a list of 14 parameters to satisfy. This will evaluate the dynamic response of the control systems to the transient, as well as verify their ability to respond as designed.
NRC Question 23.1:
To have a successful test, it is the intent of Test# 102 to generate a signal simulating the ESF (AOO), by reaching a set limit as a result of a loss of feedwater heating.
NuScale Response:
Table 14.2-102, Loss of Feedwater Heater Test # 102, is written per the guidance provided in RG 1.68 Section A-5, step kk, which states:
Demonstrate that the dynamic response of the plant is in accordance with design for the loss or bypass of the feedwater heater(s) from a credible single failure or operator error that would result in the most severe case of feedwater temperature reduction (50 percent, 90 percent).
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 16 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com For the NuScale design, this describes a condition in which an operator error results in the isolation of extraction steam to the high pressure feedwater heater. This transient does not result in an ESF actuation.
NRC Question 24.0:
Test #41-1 Objective is to verify the automatic operation of the CES to establish and maintain design vacuum for the CNV. The Associated Acceptance criteria states that the automated control establishes and maintains vacuum in the CNV.
Is there a design pressure that needs to be verified? FSAR Section 6.2.2 states that under normal operating conditions, the interior of the CNV is maintained in a dry condition under vacuum (<1 psia). Should this value be added to the Acceptance Criteria?
NuScale Response:
The Table 14.2-41, Containment Evacuation System Test # 41, Test #41-1 acceptance criteria was revised to add the statement within the design limit per Section 6.2.2.
NRC Question 24.1:
Test 41-4 Objective is to verify, in part, that the CES level instrumentation supports leak before-break leakage detection. The associated Acceptance Crtieria states that the CES detects a level increase in the CES sample tank, which correlates to a detection of an unidentified leakage rate of one gpm within one hour.
FSAR Section 5.2.5.1 Leakage Detection and monitoring states The CES condensate monitoring system can detect an RCS leak rate of less than 1 gpm within one hour and has a minimum detectable leak rate of less than 0.05 gpm. Is the minimum detectable leak rate tested as part of the system testing?
NuScale Response:
The discussion regarding 0.05 gpm is referring to the minimum sensitivity of the equipment used to detect a change in flow rate into the sample vessel. This attribute is verified as part of instrument calibration, rather than through a system level test.
To test the overall systems ability to detect and alert the Operators to a leak into the CNV, the one gpm within one hour criteria is used.
NRC Question 24.2:
FSAR Section 9.3.3, Containment Evacuation System and Containment Flooding and Drain System, States in part that the CES supports the plant sampling system (PSS), as described in Section 9.3.2 providing a suction and return path for continuous monitoring of hydrogen and oxygen concentration in the containment atmosphere; support post-accident monitoring, providing a suction path for post-accident monitoring of hydrogen and oxygen concentration in the containment atmosphere as described in Section 9.3.2. The return path for monitoring of hydrogen and oxygen concentration in the containment atmosphere is the CFDS; and support post-accident sampling, providing grab sample capability of the containment atmosphere using the CES particulate, iodine, and gaseous radiation monitor, as described in Section 9.3.2.
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 17 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com Test Abstract 41 does not address these functions. How are these functions being tested during ITP?
NuScale Response:
The following functions are located in Table 14.2-53, Process Sampling System Test # 53:
The PSS supports the CNTS during normal operations by providing sampling of containment gas and analysis of hydrogen and oxygen concentration in containment.
PSS supports the CNTS during accident condition by providing sampling of containment gas and analysis of hydrogen and oxygen concentration in containment to respond to emergencies.
Test #53-2 tests the ability of the system to continuously monitor the containment atmosphere.
For both accident and normal conditions the same sensors and line is used. The difference between the two samples is the discharge location of the sample flow. During normal conditions the sample flow is directed back to the CES, and then to the Reactor Building ventilation system or the gaseous radioactive waste system. Under accident conditions the discharge is directed back to the containment via the containment fill and drain system. The discharge flow path is determined by a remotely operated three-way solenoid valve. Operation of this valve is tested in Table 14.2-53: Process Sampling System Test #53, component level test (i).
A grab sample is obtained within the CES. Located on the CES piping is an off-line particulate, iodine, and noble gas monitor. This monitor is described in DCA section 11.5, and is identified on Table 11.5-1 under the CES heading. These monitors are similar to those on other gaseous systems and provide a connection with which to draw a grab sample. The ability to obtain a grab sample is tested in Table 14.2-41: Containment Evacuation System Test #41, component level test (viii).
NRC Question 25.0:
Test Objectives 42-1 and 42-2 are to verify that the CFDS can automatically flood and drain the CNTS in preparation for refueling and plant startup operations. The Associated Acceptance criteria states that the CNTS is flooded or drained as a result of the test activities. Are there more explicit acceptance criteria associated with either flow rates or minimum or maximum volumes per unit time for these operations specified or required to verify adequate system performance?
NuScale Response:
There are not requirements for flowrates or time to fill or drain the containment.
NRC Question 26.0:
Several System Functions associated with test abstract 43 regarding CNTS support of DHRS, RCS, or RXB system functionality by closing Containment Isolation Values (CIVs) refers the reader to Test Abstract 63-6. Stroke times for closure of the CIVs is important for ensuring plant features adequately limit radioactive releases in accordance with the design requirements/specifications. Test Abstract 63-6 does not appear to test or record stroke times for closure of the CIVs. Are stroke times for CIV closure recorded and evaluated to confirm closure times limit potential radioactive release in accordance with design requirements/assumptions?
NuScale Response:
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 18 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com Table 14.2-63: Module Protection System Test #63, Test #63-7 verifies the stroke times of the containment isolation valves.
NRC Question 27.0:
Test #108: The staff would like to discuss the RCS and vibration testing. We understand that some of the concerns from the staff may be addressed by TR-0918-60894, NuScale Comprehensive Vibration Assessment Program Measurement and Inspection Plan Technical Report. Does NuScale intend to reference this TR in the ITP?
NuScale Response:
Tables 14.2-44, 14.2-45, 14.2-72, and 14.2-108, and section 14.2.3.3, were updated to reference TR-0918-60894.
NRC Question 28.0:
Regarding Table 14.2-9, Auxiliary Boiler System Test Test #9, there should be a test to ensure that the Auxiliary Boiler blowdown to the waste system is sufficiently cooled to prevent damage to the liquid radwaste system components.
NuScale Response:
During normal operation ABS blowdown is directed through the aux boiler blowdown coolers to a tank in the balance-of-plant drain system. If a high radiation condition is detected, the BPDS that normally pump the water from the tank trip and the blowdown flow path isolates. If necessary, Operators could align the BPDS tank to be pumped to LRWS, but this will not occur automatically. Prior to conducting this evolution, the Operators can verify the temperature of the blowdown out of the coolers if there is any reason to believe temperatures might be too high for transfer to the LRWS.
Because this is controlled by the Operators, and there is no urgent need to transfer the contents of the BPDS tanks to LRWS, a test for the adequacy of cooling to ensure LRWS components are not damaged is not necessary.
NRC Question 28.1:
Regarding Table 14.2-19, Normal Control Room HVAC System Test #19, since RG 1.52 is not applicable, and the requirements are not in the technical specifications, there should be a test to make sure that the charcoal meets the minimum efficiency needed to demonstrate compliance with the design criteria.
NuScale Response:
Table 14.2-19, Normal Control Room HVAC System Test #19, prerequisite (iii) states:
Verify CRVS high-efficiency particulate air (HEPA) and charcoal adsorbers have been installed and tested and the test records have been approved.
DCA Section 9.4.1.2.1 describes the CRVS air filtration units, which include the charcoal adsorbers. Additionally, the same section states that the Components of the AFU are designed, constructed, and tested in accordance with Section C.4 of RG 1.140. RG 1.140, Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water-Cooled Nuclear Power Plants, provides the testing
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 19 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com requirements referenced in the prerequisite for Test #19. No changes to Test #19 are necessary.
NRC Question 28.2:
Regarding Table 14.2-41, Containment Evacuation System Test #41, there doesnt appear to be a test related to demonstrating that the liquid radioactive waste management system can receive liquid from the containment evacuation system.
NuScale Response:
Liquid is collected in the CES by the CES sample tank. This tank gravity drains to the radioactive waste drain system via an air-operated valve. Operation of the valve is tested in component level test i.
The ability of the liquid radwaste system to receive and process water from the radioactive waste drain system is tested in Table 14.2-23, Radioactive Waste Drain System Test # 23, system level test #23-1, and Table 14.2-35, Liquid Radioactive Waste System Test # 35, system level test #35-2.
NRC Question 28.3:
Regarding Table 14.2-95, Radiation Shield Survey Test #95, there should be a test to include neutron attenuation testing of the bioshield vertical plate borated polyethylene blocks. This test may be needed as a base line for future testing of the attenuation of the borated polyethylene blocks, as the neutron attenuation capability of the borated polyethylene could degrade over time.
NuScale Response:
Table 14.2-95, Radiation Shield Survey Test # 95, has been revised to address initial startup shielding surveys of accessible areas of the RXB in accordance with ANSI/ANS-6.3.1, Program for Testing Radiation Shields in Light Water Reactors (LWR), as endorsed by the NRC in Regulatory Guide 1.68, Initial Test Programs for Water-Cooled Nuclear Power Plants, via Regulatory Guide 1.69, Concrete Radiation Shields and Generic Shield Testing for Nuclear Power Plants.
The vertical plate of the borated polyethylene is one piece of multiple shields and potential streaming paths that will be evaluated and surveyed in accordance with previous mentioned regulatory guidance for reactor shielding initial startup testing, and therefore does not require specific identification in the test abstract.
NRC Question 28.4:
Regarding Table 14.2-95, Radiation Shield Survey Test #95, while there is a test to verify the adequacy of concrete radiation shielding from sources in the reactor vessel, there should also be radiation surveys of other areas of the plant that are expected to contain radioactive material, such as the CVCS system (at 50% and 100% power). The purpose of the surveys include to evaluate the shielding design, access controls, and the identification of high-radiation zones.
NuScale Response:
Table 14.2-95, Radiation Shield Survey Test # 95, has been revised to address initial startup shielding surveys of accessible areas of the RXB in accordance with ANSI/ANS-6.3.1, Program
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 20 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com for Testing Radiation Shields in Light Water Reactors (LWR), as endorsed by the NRC in Regulatory Guide 1.68, Initial Test Programs for Water-Cooled Nuclear Power Plants, via Regulatory Guide 1.69, Concrete Radiation Shields and Generic Shield Testing for Nuclear Power Plants. In accordance with ANSI/ANS-6.3.1, initial testing of radiation shielding will be coordinated with the routine operation surveys of the Radiation Protection Program to ensure access control to High Radiation and Very High Radiation Areas are in accordance with RG 8.38, Control of Access to High and Very High Radiation Areas in Nuclear Power Plants.
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 21 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com Table of Acronyms Acronym or Abbreviation Description ABS Auxiliary boiler system AFU Air filtration unit BPDS Balance of plant drain system CAR Condenser air removal CVCS Chemical and volume control system CES Containment evacuation system CFDS Containment flooding and drain system CIV Containment isolation valve CNTS Containment system CNV Containment vessel CPS Condensate polishing system CRA Control rod assembly CRDS Control rod drive system CRVS Normal control room HVAC system DHRS Decay heat removal system ECCS Emergency core cooling system EDSS Highly reliable DC power system ELVS Low voltage AC electrical distribution system ESF Engineered safety feature ESFAS Engineered safety features actuation system FAT Factory acceptance testing FSAR Final Safety Analysis Report FWS Feedwater system HEPA High efficiency particulate air HP High pressure HSI Human-system interface ICIS In-core instrumentation system IHA Important human action ITAAC Inspections, Tests, Analyses, and Acceptance Criteria ITP Initial test program LP Low pressure LRWS Liquid radioactive waste system LWR Light Water Reactor MC Main condenser MCR Main control room MHS Module heatup system MPS Module protection system NFPA National Fire Protection Association NMS Neutron monitoring system NPM NuScale Power Module PCS Plant control system PLS Plant lighting system PPS Plant protection system
NuScale Responses to ITP Questions LO-0119-64396 Attachment Page 22 of 22 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com PSCS Pool surge control system PSS Plant sampling system RCS Reactor coolant system RG Regulatory Guide RMS Fixed area radiation monitoring system RRV Reactor recirculation valve RSS Remote shutdown station RVI Reactor vessel internals RVV Reactor vent valve RXB Reactor Building SAT Site acceptance testing SDIS Safety display and indication system SG Steam generator SSC Structures, systems, and components TG Turbine generator UHS Ultimate heat sink
LO-0119-64396 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com
Enclosure:
Changes to NuScale Final Safety Analysis Report Sections 14.2, Initial Plant Test Program and Section 14.3, Certified Design Material and Inspections, Test, Analyses, and Acceptance Criteria
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-3 Draft Revision 3 wiring continuity and separation checks The testing and installation of digital I&C systems is described in FSAR Section 7.2.1, and includes factory acceptance testing and site acceptance testing which is completed as part of construction and installation tests performed prior to, and as a prerequisite of, preoperational tests. Factory acceptance tests are performed during the digital I&C system testing phase described in FSAR Section 7.2.1.1.3.1. Site installation and checkout activities are performed as part of the integrated site acceptance testing during the system installation phase as described in FSAR Section 7.2.1.1.3.2. Software integration and testing is governed by the NuScale Digital I&C Software Master Test Plan described in FSAR Section 7.2.1.2.8.
14.2.1.2 Preoperational Test Phase Objectives Preoperational tests are performed to demonstrate that SSC operate in accordance with design requirements so that initial fuel loading, initial criticality, and subsequent power operation can be safely undertaken. The objectives of the preoperational test phase are to demonstrate that SSC will perform their functions in accordance with their design during the preoperational test phase.
verify and demonstrate expected operation following a loss of power sources and in degraded modes for which the systems are designed to remain operational.
test the backup power supply system (BPSS) to ensure that backup sources of alternating current (AC) electrical power are available when the normal AC power sources are not available.
verify and demonstrate the operational readiness of valves and dynamic restraints before relying on those components to perform their safety functions.
perform inspections or testing for flow-induced vibration loads on components that must maintain their structural integrity.
obtain baseline test and operating data on equipment and systems for future reference.
operate equipment for a sufficient period of time to achieve normal equilibrium conditions (e.g., temperatures and pressures) so that design, manufacturing, and installation defects can be detected and corrected.
ensure to the extent practical plant systems operate properly on an integrated basis.
evaluate normal, abnormal, and emergency operating procedures to the extent practical.
demonstrate equipment performance.
test, as appropriate, manual operation and automatic operation of systems and their components.
test the proper functioning of controls, permissives, interlocks, and equipment protective devices for which malfunction or premature actuation may shut down or defeat the operation of systems or equipment.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-10 Draft Revision 3 Important Human Actions for CVC addition of water to the reactor coolant system Credit is taken for the logic testing performed for the nonsafety-related module control system (MCS) described in Section 7.0.4.5, and the nonsafety-related plant control system (PCS) described in Section 7.0.4.6. Therefore, if the component is controlled by MCS or PCS, the component-level logic testing in the preoperational test is limited to the testing of component-level design features described below (if the design feature is applicable to the system) unless the preoperational test verifies an ITAAC. The component tests are standardized to provide the same level of test detail across all systems. This graded approach does not affect system-level tests which require integrated system operation. The standardized component tests are:
Remote operation of equipment.
Manual control of variable-speed pump or fan.
Automatic start of standby pump or fan.
Automatic operation of pump recirculation valve.
Pump start does not create a water hammer.
Remote operation of valve or damper.
Valve or damper fails to its safe position on loss of air.
Valve or damper fails to its safe position on loss of electrical power to its solenoid.
Damper or fan responds to fire or smoke alarm.
Equipment response to automatic signals to protect plant equipment.
Automatic operation of tank or basin level control valve.
Local grab sample can be obtained from a system grab sample device.
Automatic bus transfer via bus tie breaker.
System instrument calibration.
Each instrument is monitored in the MCR and the remote shutdown station (RSS), if the signal is designed to be displayed in the RSS. (Test not required if the instrument calibration verified the MCR and RSS display.)
Equipment protection logic 14.2.3.3 Testing of First-of-a-Kind Design Features RAI 14.02-1 First-of-a-kind (FOAK) tests are new, unique, or special tests used to verify design features that are being reviewed for the first time by the NRC. The NuScale Power Plant contains design features which are new and unique and have not been tested previously; therefore, testing of these design features is treated as FOAK. For the FOAK tests, the testing frequency is specified in the test abstract. The NuScale comprehensive vibration assessment program is a FOAK program. The program is implemented consistent with the requirements of the NuScale "Comprehensive Vibration Assessment Program (CVAP) Technical Report", TR-0716-50439, Revision 1 and the
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-11 Draft Revision 3 NuScale Comprehensive Vibration Assessment Program Measurement and Inspection Plan Technical Report, TR-0918-60894, Revision 0. The CVAP is addressed in Section 3.9.2.
RAI 14.02-1 The following ITP test abstracts describe the on-site CVAP testing of FOAK design features:
Table 14.2-44: Control Rod Drive System Flow-Induced Vibration Test #44 Table 14.2-45: Reactor Vessel Internals Flow-Induced Vibration Test #45 Table 14.2-75: Steam Generator Flow-Induced Vibration Test #72.
Table 14.2-108: NuScale Power Module Vibration Test #108 RAI 05.04.07-7S1, RAI 14.02-1 The test results for the CVAP program testing of the first NPM are to inform the required CVAP testing on subsequent NPMs as described in Section 6.0 of TR-0716-50439. All other ITP testing of FOAK design features is performed for each NPM, except as described below.
RAI 05.04.07-7S1 Section 5.4.3.4 contains a description of the DHRS one-time in-situ RCS heat removal test. The test will be performed per test abstract Table 14.2-48: Decay Heat Removal System Test # 48.
RAI 14.02-1 Table 14.2-110 provides a summary of the ITP testing (i.e., preoperational and startup testing) for new design features. Each test will be performed for all NPMs.
RAI 14.02-1 Section 1.5.1 contains a description of testing programs which have been completed or are currently in progress for NuScale design features for which applicable data or operational experience did not previously exist. The section describes tests specific to fuel design, steam generator (SG) and control rod assemblies.
14.2.3.4 Generic Component Testing Component testing is generally executed after a systems transfer from the construction organization to the startup organization. Generic component testing executes standardized tests for a family of related component types, independent of the components system assignment. Each generic component test procedure will be completed and approved before the component is required as a prerequisite to a preoperational test performance. The completion of generic component testing will be listed as a prerequisite in each preoperational test procedure as applicable.
Examples of components that may require generic component testing are as follows:
Mechanical Components
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-26 Draft Revision 3 System Level Test #4-1 Test Objective Test Method Acceptance Criteria Verify PSCS automatic control for dry dock fill and drain.
Align the PSCS for fill and drain of the dry dock.
Fill the dry dock to a level that allows operation of the reactor inspection dry dock evacuation pump.
i.
Start a PSCS pump. and ii.
sSimulate the following PSCS conditions:
a.
Dry dock low level b.
PSC tank high level iii. Open PSCS tank main discharge line isolation valve.
iv. c.Simulate a Hhigh dry dock level.
i.
Verify inventory addition to the PSCS tank.
ii.
a.
Pump is stopped and return line to pool surge control tank isolation valve is closed.
b.
Pump is stopped and return line to PSCS tank isolation valve is closed.
iii. Verify inventory addition to the dry dock.
iv. c.PSCS tank main discharge line isolation valve is closed.
Table 14.2-4: Pool Surge Control System Test # 4 (Continued)
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-68 Draft Revision 3 Table 14.2-25: Fire Protection System Test # 25 Preoperational test is required to be performed once, and is conducted in accordance with the applicable criteria in codes and standards listed in Table 9.5.1-1.
The fire protection system (FPS) is described in Section 9.5.1 and the functions verified by this test are:
System Function System Function Categorization Function Verified by Test #
1.
The FPS supports the following buildings and systems by providing fire prevention, detection, and suppression.
- RXB
- TGB
- RWB
- Security Buildings
- ANB
- Diesel Generator Building
- Administration and Training Building
- Warehouse Building
- Fire Water Building
- site plant cooling structures
- Central Utility Building
- 13.8 KV and SWYD system (EHVS)
- medium voltage AC electrical distribution system (EMVS)
- low voltage AC electrical distribution system (ELVS)
- RWBVS
- RBVS nonsafety-related Component-level tests 2.
The FPS supports the CRB by providing audible and visual alarms to alert operators in the MCR.
nonsafety-related Component-level test vii Prerequisites i.
Verify an instrument calibration has been completed, with approved records and within all calibration due dates, for all instruments required to perform this test.
ii.
Verify a pump curve test has been completed for the fire protection pumps.
Component Level Tests Test Objective Test Method Acceptance Criteria i.
Verify position indication for each FPS manual valve with remote position indication.
Operate each valve manually.
MCR display and local, visual observation indicate each valve fully opens and fully closes.
ii.
Verify each FPS air-operated valve fails to its safe position on loss of air.
Place each valve in its non-safe position.
Isolate and vent air to the valve.
MCR display and local, visual observation indicate each valve fails to its safe position.
iii. Verify each FPS air-operated valve fails to its safe position on loss of electrical power to its solenoid.
Place each valve in its non-safe position.
Isolate electrical power to each air-operated valve.
MCR display and local, visual observation indicate each valve fails to its safe position.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-70 Draft Revision 3 Table 14.2-26: Fire Detection System Test # 26 Preoperational test is required to be performed once, and is conducted in accordance with the applicable criteria in codes and standards listed in Table 9.5.1-1.
The fire detection system (FDS) is described in Section 9.5.1 and the functions verified by this test are:
System Function System Function Categorization Function Verified by Test #
As described in Test Abstract Table 14.2-25 nonsafety-related As described in Test Abstract Table 14.2-25 Prerequisites As described in Test Abstract Table 14.2-25 Component Level Tests As described in Test Abstract Table 14.2-25 System Level Tests As described in Test Abstract Table 14.2-25
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-82 Draft Revision 3 Component Level Tests Test Objective Test Method Acceptance Criteria i.
Verify each TGS remotely-operated valve can be operated remotely.
Operate each valve from the MCR and local control panel (if design has local valve control).
MCR display and local, visual observation indicate each valve fully opens and fully closes.
ii.
Verify each TGS air-operated valve fails to its safe position on loss of air.
Place each valve in its non-safe position.
Isolate and vent air to the valve.
MCR display and local, visual observation indicate each valve fails to its safe position.
iii. Verify each TGS air-operated valve fails to its safe position on loss of electrical power to its solenoid.
Place each valve in its non-safe position.
Isolate electrical power to each air-operated valve.
MCR display and local, visual observation indicate each valve fails to its safe position.
iv. Verify each TGS lube oil pump can be started and stopped remotely.
Align the TGS to allow for main lube oil, auxiliary lube oil, and emergency pump operation.
Stop and start each pump from the MCR.
MCR display and local, visual observation indicate each pump starts and stops.
Audible and visible water hammer are not observed when the pump starts.
v.
Verify the TGS exhaust hood is protected against high temperature.
Initiate a simulated high exhaust hood temperature.
Any remote display or the local, visual observation indicates the exhaust hood spray valve is open.
vi. Verify TGS lubricating oil flow capability by automatic start of the auxiliary lube oil pump.
Align the TGS to allow for main lube oil and auxiliary lube oil pump operation.
Place the TGS main oil pump in normal service. Place the auxiliary oil pump in standby.
Simulate a TGS auxiliary oil pump start.
MCR display and local, visual observation indicate the auxiliary oil pump starts.
Audible and visible water hammer are not observed when the pump starts.
vii. Verify TGS lubricating oil flow capability by automatic start of the emergency direct current (DC) lube oil pump.
Align the TGS to allow for auxiliary lube oil pump and emergency lube oil pump operation. Place the turbine generator auxiliary oil pump in normal service.
Simulate a turbine generator emergency oil pump start or simulate a loss of ac power.
MCR displays and local, visual observation indicate the TGS emergency oil pump starts.
Audible and visible water hammer are not observed when the pump starts.
viii. Verify the turbine stop valve and turbine control valves close on turbine overspeed.
i.
a.
Simulate an overspeed trip signal from the turbine overspeed emergency trip system.
b.
Record the stroke times of the turbine stop valve and the turbine control valves.
ii.
a.
Simulate an overspeed trip signal from the governor overspeed detection circuit.
b.
Record the stroke times of the turbine stop valve and the turbine control valves.
i.
a.
The turbine stop valve and turbine control valves close.
b.
Each turbine stop valve and turbine control valve close stroke time is within design limits.
ii.
a.
The turbine stop valve and turbine control valves close.
b.
Each turbine stop valve and turbine control valve close stroke time is within design limits.
ix. Verify a local grab sample can be obtained from the gland seal exhauster discharge grab sample device.
Place the system in service to allow flow through the grab sample device.
A local grab sample is obtained.
x.
Verify the turbine can be manually tripped.
Manually trip the turbine from an operator workstation in the MCR.
The turbine stop valve and turbine control valves close.
Table 14.2-33: Turbine Generator System Test # 33 (Continued)
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-83 Draft Revision 3 xi. Verify each TGS instrument is available on an MCS or PCS display.
(Test not required if the instrument calibration verified the MCS or PCS display.)
Initiate a single real or simulated instrument signal from each TGS transmitter.
The instrument signal is displayed on an MCS or PCS display, or is recorded by the applicable control system historian.
System Level Test #33-1 Test Objective Test Method Acceptance Criteria i.
Verify the CVCS is capable of supplying water at sufficient pressure to close the ECCS valves.
ii.
Verify the MHS is capable of heating the RCS to a temperature sufficient to obtain criticality.
iii. Verify the MHS is capable of heating the RCS to establish natural circulation flow sufficient to obtain criticality.
ivii. Verify the TGS automatically controls turbine bypass flow to the main condenser.
iv. Verify the FWS automatically controls flow to the SGs to maintain SG inventory.
vi. Verify the FWS automatically cools the TGS bypass steam flow in the main steam desuperheater.
vii. Verify a local grab sample can be obtained from an MHS system grab sample device.
viii. Verify the FWS automatically cools the TGS gland steam in the gland steam desuperheater.
ix. Verify hotwell level is automatically controlled while receiving bypass steam.
Close the ECCS valves.
Align the plant to cool the RCS via the TGS bypass system.
Warm main steam lines.
Place the TGS steam bypass valve in automatic control.
Place the feedwater regulating valve in steam generator inventory control.
Place the MHS and the CVCS in automatic control to heat the RCS.
Place the ABS high-pressure system in automatic control to heat the MHS heat exchanger from RCS ambient temperature to the highest temperature achievable by MHS heating.
Align the FWS to cool the gland seal steam desuperheater.
i.
CVCS pressure is sufficient as indicated by closure of the ECCS valves.
ii. a. CVCS supply remains in a sub-cooled state while heating the RCS using the module heatup system as verified by CVCS temperature and pressure.
- b. RCS temperature is sufficient to obtain criticality.
iii. RCS natural circulation flow is sufficient to obtain criticality.
ivii. The TGS bypass flow is maintained maintains steam pressure at setpoint.
iv. The feedwater flow to the steam generator is maintained at setpoint.
vi. The cooled TGS bypass flowtemperature is maintained at setpoint.
vii. A local grab sample is successfully obtained at RCS normal operating temperature and pressure.
viii. The cooled gland seal steam temperature is maintained at setpoint.
ix. Hotwell level is maintained at setpoint while receiving bypass steam.
System Level Test #33-2 This test may be performed after the completion of Test 33-1 when the RCS is at normal operating pressure and the RCS has achieved the maximum temperature achievable by warming the RCS using MHS heating.
Test Objective Test Method Acceptance Criteria Verify the maximum main turbine speed that can be obtained using the MHS to heat the RCS.
Place the main turbine in service as follows:
i.
Ensure the RCS is at RCS is at normal operating pressure and the RCS is at maximum temperature achievable by warming the RCS using MHS heating.
ii.
Place turbine on turning gear with seal steam in service.
iii. Warm up turbine to required temperature.
iv. Increase main turbine speed.
The maximum main turbine speed is obtained.
Table 14.2-33: Turbine Generator System Test # 33 (Continued)
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-97 Draft Revision 3 System Level Test #38-1 Test Objective Test Method Acceptance Criteria Verify proper operation of the automatic pressurizer level control.
This test will be performed in conjunction with turbine generator test #33-1, which heats the RCS from ambient conditions to no less than 4205°F but as high as reasonably achievable.
i.
For pressurizer automatic level control on the low end of the design operating band usePlace pressurizer level control in automatic operation during RCS heatup to demonstrate automatic letdown. Use the module control system (MCS) data historian to review pressurizer level at maximum-obtained RCS temperature.
ii.
To raise pressurizer level, use MCS automation and operator permission to increase to a target pressurizer level.
Note: Pressurizer letdown level control is automatic; however pressurizer makeup level control is automatic with consent of operator.
i.
MCS data indicates that automatic pressurizer level control is maintained within the design operating level band.letdown maintained pressurizer level at setpoint as described in Section 9.3.4.5.
ii.
MCS data indicates that the pressurizer level control results in an increased pressurizer level within acceptable limits of the target pressurizer level.CVCS makeup to the RCS to increase pressurizer level to the target setpoint as described in Section 9.3.4.5.
System Level Test #38-2 Test Objective Test Method Acceptance Criteria Verify proper operation of the automatic pressurizer pressure control.
This test will be performed in conjunction with turbine generator test #33-1 which heats the RCS from ambient conditions to no less than 4205°F but as high as reasonably achievable.
Place pressurizer pressure control in automatic and raise pressure setpoint to the normal operating band.
Raise pressurizer pressure to the pressurizer spray valve open setpoint.
Use the MCS data historian to review pressurizer pressure at maximum-obtained RCS temperature.
i.
MCS data indicates automatic pressurizer heater operation raised pressurizer pressure to the setpoint as described in Section 9.3.4.5.
ii.
MCS data indicates automatic pressurizer spray valve operation lowered pressurizer pressure to the spray valve closure setpoint as described in Section 9.3.4.5.MCS data indicates that automatic pressurizer pressure control is maintained within the design operating pressure band.
Table 14.2-38: Chemical and Volume Control System Test # 38 (Continued)
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-98 Draft Revision 3 System Level Test #38-3 Test Objective Test Method Acceptance Criteria Verify proper operation of CVCS automatic dilution and boration control.
This test will be performed in conjunction with turbine generator test #33-1 which heats the RCS from ambient conditions to no less than 4205°F but as high as reasonably achievable.
Ensure that RCS low flow rate alarm is clear to ensure adequate mixing for dilution and boration.
i.
Place the boron addition system (BAS) storage tank on recirculation and sample boron concentration.
ii. Use the MCS automation and operator permission to decrease to a target RCS boron concentration.
iii. Use the MCS and operator permission to increase to a target RCS boron concentration.
i.
BAS storage tank sample boron concentration is within specifications (as described in Section 9.3.4.2.1).
ii. MCS data indicates that the dilution of the RCS results in a decreased boron concentration within acceptable limits of the target concentration as described in Section 9.3.4.5.
iii. MCS data indicates that the boration of the RCS results in a increased boron concentration within acceptable limits of the target concentration as described in Section 9.3.4.5.
Table 14.2-38: Chemical and Volume Control System Test # 38 (Continued)
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-104 Draft Revision 3 viii. Verify a local grab sample can be obtained from a CES grab sample device indicated on the CES piping and instrumentation diagram.
Place the system in service to allow flow through the grab sampling device.
A local grab sample is successfully obtained.
ix. Verify each CES instrument is available on an MCS or PCS display.
(Test not required if the instrument calibration verified the MCS or PCS display.)
Initiate a single real or simulated instrument signal from each CES transmitter.
The instrument signal is displayed on an MCS or PCS display, or is recorded by the applicable control system historian.
System Level Test #41-1 Test Objective Test Method Acceptance Criteria Verify the automatic operation of the CES to establish and maintain design vacuum for the CNV.
After the containment flooding and drain system (CFDS) completes draindown of the CNV and the NPM is in hot functional testing, place the CES in automatic operation.
The automated control establishes and maintains vacuum in the CNV within design limit per Section 6.2.2.
System Level Test #41-2 Test Objective Test Method Acceptance Criteria Verify radiation isolation and flow diversion on high radiation level in the CES.
The NPM is in hot functional testing with the RCS at normal operating pressure.
The CES is operating in automatic control with a CNV steady-state vacuum pressure indicating the noncondensable gases have been removed from the CNV.
Initiate a real or simulated high radiation signal for the CES vacuum pump discharge.
i.
The CES effluent flow path to the RBVS is isolated and diverted to GRWS.
[ITAAC 02.07.01]
ii.
The CES effluent to process sample panel isolation valve is closed.
[ITAAC 02.07.01]
iii. The CES purge air solenoid valves to the vacuum pumps are closed.
[ITAAC 02.07.01]
iv. The automated control maintains vacuum in the CNV.
Table 14.2-41: Containment Evacuation System Test # 41 (Continued)
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-110 Draft Revision 3 RAI 14.02-1 Table 14.2-44: Control Rod Drive System Flow-Induced Vibration Test # 44 Validation testing is performed during factory testing on the control rod drive shaft per Table 4-1 of TR-0716-50439. There are no preoperational tests for CRDS.
The CRDS flow-induced vibration testing is performed consistent with the requirements of the NuScale Comprehensive Vibration Assessment Program as described in Section 5.0 of the Comprehensive Vibration Assessment Program (CVAP)
Technical Report, TR-0716-50439 and Section 6.0 of the NuScale Comprehensive Vibration Assessment Program Measurement and Inspection Plan Technical Report, TR-0918-60894, Revision 0. Visual examination of the CRDS components is performed as specified in Table 5-1 of TR-0716-50439. This test is coordinated with Test #108. The CVAP is addressed in Section 3.9.2. The CRDS is discussed in Section 4.6.
System Function System Function Categorization Function Verified by Test #
None N/A N/A Prerequisites:
N/A Component Level Tests None
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-111 Draft Revision 3 RAI 14.02-1 Table 14.2-45: Reactor Vessel Internals Flow-Induced Vibration Test # 45 Validation testing is performed at the factory for the in-core instrument guide tubes per Table 4-1 of TR-0716-50439. There are no preoperational tests for RVI.
RVI flow-induced vibration testing is performed consistent with the requirements of the NuScale Comprehensive Vibration Assessment Program as described in Section 5.0 of the Comprehensive Vibration Assessment Program (CVAP) Technical Report, TR- 0716-50439 and Section 6.0 of the NuScale Comprehensive Vibration Assessment Program Measurement and Inspection Plan Technical Report, TR-0918-60894, Revision 0. Visual examination of the RVI components is performed as specified in Table 5-1 of TR-0716-50439. This test is coordinated with Test #108. The CVAP is addressed in Section 3.9.2.
Reactor vessel internals are discussed in Section 5.1.3.3.
System Function System Function Categorization Function Verified by Test #
None N/A N/A Prerequisites:
N/A Component Level Tests None
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-113 Draft Revision 3 Table 14.2-47: Emergency Core Cooling System Test # 47 Preoperational test is required to be performed for each NPM.
The ECCS is described in Section 6.3, and the. The ECCS functions are not verified by ECCS tests. The ECCS functions verified by thisother tests are:
System Function System Function Categorization Function Verified by Test #
1.
The ECCS supports the RCS by opening the ECCS reactor vent valves and reactor recirculation valves when their respective trip valve is actuated by the MPS.
safety-related Test #47-1 MPS Test #63-6 2.
The ECCS supports the RCS by providing recirculated coolant from the containment to the RPV for the removal of core heat.
safety-related Test #47-1 MPS Test #63-6 The ECCS functions verified by other tests are:
System Function System Function Categorization Function Verified by Test #
3.
The ECCS supports the RCS by providing low temperature overpressure protection (LTOP) for maintaining the reactor coolant pressure boundary.
safety-related MPS Test #63-6 4.
The ECCS supports the CNTS by providing a portion of the containment boundary for maintaining containment integrity.
safety-related CNTS Test #43-1 5.
The ECCS supports MPS by providing post accident monitoring instrument information signals.
nonsafety related SDIS Test #66-2 Prerequisites Verify an instrument calibration has been completed, with approved records and within all calibration due dates, for all instruments required to perform this test.Prerequisites associated with ECCS testing are identified in the referenced test abstract cited under the Function Verified by Test # heading.
Component Level Tests None System Level Tests #47-1 Test 47-1 is performed at hot functional testing concurrently with TGS Test #33-1 (reference Table 14.2.-33) and MPS Test #63-6 to allow testing of ECCS actuation at normal operating pressure and elevated temperatures. Test #33-1 heats the RCS from ambient conditions to the highest temperature achievable by MHS heating. These hot functional testing conditions provide the highest differential pressure and temperature conditions that can be achieved prior to fuel load.
None Test Objective Test Method Acceptance Criteria i.
Verify collapsed liquid level remains above the top of the core during ECCS actuation.
ii.
Containment vessel pressure remains below the design pressure limit during ECCS actuation.
iii. Containment temperature remains below the design temperature limit during ECCS actuation.
Ensure the RCS is at normal operating pressure and at maximum temperature achievable by warming the RCS using MHS heating.
i.
Manually initiate ECCS from the MCR.
ii.
Allow RPV riser level and CNV level to become relatively stable.
i.
RPV riser level remains above the top of the core.
ii.
CNV pressure remains below design pressure identified in Table 6.2-1.
iii. CNV temperature remains below design temperature identified in Table 6.2-1.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-142 Draft Revision 3 Table 14.2-60: Plant Lighting System Test # 60 Preoperational test is required to be performed once.
The plant lighting system (PLS) is described in Section 9.5.3 and the functions verified by this test are:
System Function System Function Categorization Function Verified by Test #
1.
PLS supports the CRB by providing normal lighting.
nonsafety-related component-level test i.
2.
The PLS supports the CRB by providing emergency lighting in the main control room.
nonsafety-related component-level test ii.
3.
The PLS supports the RXB by providing normal lighting.
nonsafety-related component-level test i.
4.
The PLS supports the RXB by providing emergency lighting for the remote shutdown station.
nonsafety-related component-level test ii.
5.
The PLS supports the RXB by providing emergency lighting for post-fire safe-shutdown activities outside of the MCR and RSS.
nonsafety-related component-level test iii.
Prerequisites N/A (Note: Component level test iii. supports ITAAC and the requirements of NFPA 804.)
Component Level Tests Test Objective Test Method Acceptance Criteria i.
Verify the PLS provides normal illumination of the MCR and RSS operator workstations, and the MCR safety display information panel.
With normal MCR and RSS lighting in service, measure the light at each MCR and RSS workstation.
i.
a.
The PLS provides at least 100 foot-candles illumination at the MCR operator workstations and at least 50 foot-candles at the MCR auxiliary panels.
[ITAAC 03.08.01]
i.
b.
The PLS provides at least 100 foot-candles illumination at the RSS operator workstations.
[ITAAC 03.08.01]
ii.
The PLS provides emergency illumination of the MCR and RSS operator workstations and the MCR safety display information panel.
With MCR and RSS emergency illumination in service, measure the light at each MCR and RSS workstation and MCR safety display information panel.
ii.
a.
The PLS provides at least 10 foot-candles of illumination at the MCR operator workstations and the RSSMCR safety display informationauxiliary panels.
[ITAAC 03.08.02]
ii.
b.
The PLS provides at least 10 foot-candles at the RSS operator workstations.
[ITAAC 03.08.02]
iii. Verify the eight-hour battery pack emergency lighting fixtures provide illumination for post-fire safe-shutdown activities performed by operators outside the MCR and RSS.
With no AC power available, measure the light at each eight-hour battery pack emergency lighting fixture target area.
iii. The required target areas are illuminated to provide at least one foot-candle illumination in the areas outside the MCR or RSS where post-fire safe-shutdown activities are performed.
[ITAAC 03.08.03]
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-144 Draft Revision 3 Table 14.2-61: Module Control System Test # 61 Preoperational test is required to be performed as indicated by tests for MCS-controlled systems and systems providing data to the MCS.
The MCS is described in Section 7.0.4.5. The Remote Shutdown Station (RSS) is described in Section 7.1.1.2.3.
On-site testing of the system is performed by an MCS site acceptance test (SAT).
The MCS is a distributed control system which allows monitoring and control of NPM-specific plant components. The MCS includes all manual controls and visual display units necessary to provide operator interaction with the process control mechanism.
The boundary of the MCS is at the terminations on the MCS hardware. The MCS supplies nonsafety inputs to the human-system interfaces (HSIs) for nonsafety displays in the MCR, the remote shutdown stationRSS, and other locations where module control system HSIs are necessary. There are two boundaries between MCS and MPS, the fiber-optic isolated portion and the hard-wired module boundary. The MCS has a direct, bi-directional interface with the PCS.
A complete staging and testing of system hardware and software configurations will be conducted. This factory acceptance testing will be conducted in accordance with a written test procedure for testing the software and hardware of the MCS prior to installation in the plant. Following installation, site acceptance testing shall be completed in accordance with developed procedures to ensure the MCS is installed and fully functional as designed.
To ensure the MCS communicates with module-specific plant components, component-level testing is performed on all systems controlled by MCS to manually operate the associated components from the main control room and remote shutdown station. By design, operation of components from the MCR also verifies the ability to operate the components from the RSS. These component-level tests are described in the test abstracts of the systems that contain the actuated components.
In addition, it is verified that each instrument supplying data to the MCS is component tested in preoperational test abstracts to ensure the signal is available on an MCS or PCS display. These component-level tests are described in the test abstracts of the systems that contain the instrument.
The RSS provides an alternate location to monitor the NPM status and operate the MCS and PCS during a MCR evacuation.
The ability to activate the nonsafety MCS and PCS displays and controls at the RSS will be verified during site acceptance testing. The ability to isolate the safety-related MCR module protection system (MPS) manual switches using the MCR isolation switches in the RSS as described in Section 7.2.12 will be verified during MPS factory and site acceptance testing.
System Function System Function Categorization Function Verified by Test #
The MCS supports the Reactor Building by providing indication and operator display to the Remote Shutdown Station, which resides in the Reactor Building.
nonsafety-related Factory Acceptance Testing and Site Acceptance Testing as described above.
Prerequisites Prerequisites associated with MCS testing are identified in the test abstracts that contain module-specific components that ensure communication with the MCS.
Component Level Tests None System Level Tests None
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-145 Draft Revision 3 Table 14.2-62: Plant Control System Test # 62 Preoperational test is required to be performed as indicated by tests for PCS-controlled systems and systems providing data to the PCS.
The PCS is described in Section 7.0.4.6. The Remote Shutdown Station (RSS) is described in Section 7.1.1.2.3.
On-site testing of the system is performed by a PCS site acceptance test (SAT).
The PCS is a distributed control system which allows monitoring and control of virtually all module-specific plant components. The PCS includes all manual controls and visual display units necessary to provide operator interaction with the process control mechanism.
The boundary of the PCS is at the terminations on the PCS hardware. The PCS supplies nonsafety inputs to the video display units (VDUs) for nonsafety displays in the MCR, the RSS, and other locations where PCS video display units are necessary. The boundary between the PPS and PCS is at the output connection of the safety-related optical isolators in the PPS, and on the terminals of the equipment interface module for each input from the PCS to the PPS.
The PCS has a direct, bidirectional interface with the MCS. The network interface devices for the PCS domain controller/
historian provide the interface between the human machine interface network layer and the control network layer.
A complete staging and testing of system hardware and software configurations will be conducted. This factory acceptance testing will be conducted in accordance with a written test procedure for testing the software and hardware of the PCS prior to installation in the plant. Following installation, site acceptance testing shall be completed in accordance with developed procedures to ensure the PCS is installed and fully functional as designed.
To ensure the PCS communicates with module-specific plant components, component-level testing is performed on all systems controlled by PCS to manually operate the associated components from the main control room and remote shutdown station. By design, operation of components from the MCR also verifies the ability to operate the components from the RSS. These component-level tests are described in the test abstracts of the systems that contain the actuated components.
In addition, it is verified that each instrument supplying data to the PCS is component tested in preoperational test abstracts to ensure the signal is available on an MCS or PCS display. These component-level tests are described in the test abstracts of the systems that contain the instrument.
The RSS provides an alternate location to monitor the NPM status and operate the MCS and PCS during a MCR evacuation.
The ability to activate the nonsafety MCS and PCS displays and controls at the RSS will be verified during site acceptance testing. The ability to isolate the safety-related MCR module protection system (MPS) manual switches using the MCR isolation switches in the RSS as described in Section 7.2.12 will be verified during MPS factory and site acceptance testing.
System Function System Function Categorization Function Verified by Test #
The PCS supports the Reactor Building by providing indication and operator display to the Remote Shutdown Station, which resides in the Reactor Building.
nonsafety-related Factory Acceptance Testing and Site Acceptance Testing as described above.
Prerequisites Prerequisites associated with PCS testing are identified in the test abstracts that contain module-specific components that ensure communication with or are controlled by the PCS.
Component Level Tests None System Level Tests None
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-146 Draft Revision 3 Table 14.2-63: Module Protection System Test #63 Preoperational test is required to be performed for each NPM.
The MPS is described in Sections 7.0, 7.1, and 7.2 and the functions verified by this test and power ascension testing are:
System Function System Function Categorization Function Verified by Test #
1.
The MPS supports the CNTS by removing electrical power to the trip solenoids of the following CIVs on a containment system isolation actuation signal:
- RCS injection containment isolation valves
- RCS discharge containment isolation valves
- Pressurizer spray containment isolation valves
- RPV high point degasification containment isolation valves
- Feedwater containment isolation valves
- Main steam containment isolation valves
- Main steam bypass valves
- CES containment isolation valves
- RCCWS containment isolation valves
- CFDS containment isolation valves safety-related Test #63-4 Test #63-6 2.
The MPS supports the CNTS by removing electrical power to the trip solenoids of the following valves on a DHRS actuation signal.
- DHRS actuation valves
- Main steam bypass isolation valves
- Feedwater isolation valves safety-related Test #63-4 Test #63-6 3.
The MPS supports the ECCS by removing electrical power to the trip solenoids of the following valves on an ECCS actuation signal.
- Reactor vent valves
- Reactor recirculation valves safety-related Test #63-4 Test #63-6
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-169 Draft Revision 3 RAI 14.02-1 Table 14.2-72: Steam Generator Flow-Induced Vibration Test # 72 Validation testing is performed at test facilities as separate effects tests on prototypic steam generator tube columns and steam generator inlet flow restrictors per Table 4-1 of TR-0716-50439. There are no preoperational tests for SG.
SG flow-induced vibration testing is performed consistent with the requirements of the NuScale Comprehensive Vibration Assessment Program as described in the Comprehensive Vibration Assessment Program (CVAP) Technical Report, TR-0716-50439, Revision 1, and the NuScale Comprehensive Vibration Assessment Program Measurement and Inspection Plan Technical Report TR-0918-60894, Revision 0. Visual examination of the SG components is performed as specified in Table 5-1 of TR-0716-50439. This test is coordinated with Test #108. The CVAP is addressed in Section 3.9.2. The steam generators are discussed in Section 5.4.1.
System Function System Function Categorization Function Verified by Test #
None N/A N/A Prerequisites:
N/A Component Level Tests None
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-173 Draft Revision 3 Table 14.2-76: Initial Fuel Load Test # 76 The Initial Fuel Load Test is required to be performed for each NPM.
This test is performed prior to initial fuel load.
Test Objectives i.
Conduct initial fuel load with no inadvertent criticality.
ii.
Install fuel assemblies and control components at the locations specified by the design of the initial RXC.
Prerequisites i.
Plant systems required for initial fuel loading have completed preoperational testing.
ii.
Plant systems required for initial fuel loading have been aligned per operations procedures.
iii. The design of the initial RXC that specifies the final core configuration of fuel assemblies and control components is completed.
iv. A core load sequence has been approved.
v.
Neutron monitoring data from a previous NPM initial fuel loading or calculations showing the predicted response of monitoring channels are available for evaluating monitoring data.
vi. The lower RPV is installed in the RPV support stand.
vii. Control room communications are established.
viii. RXB radiation monitors are functional.
ix. Boron concentration in the pool is within Technical Specification limits.
x.
The nuclear instrumentation system is calibrated and operable.
Test Method i.
The overall process of initial fuel loading will be supervised by a licensed senior reactor operator with no other concurrent duties.
ii.
Install fuel and control components per approved procedures.
iii. Monitor boron concentration inside the RPV periodically during fuel load to ensure it satisfies TS.
iv. Monitor neutron counts during the load of each fuel assembly and plot an independent inverse count rate ratio for each source range detector after each fuel load assembly is loaded.
v.
Verify neutron count data are consistent with calculations showing the predicted response. For fuel loading of the second NPM and all subsequent NPMs use data obtained from previous fuel loadings.
vi. Demonstrate the inverse count rate ratio does not show significant approach to criticality.
vii. Maintain the status of the core loading.
viii. Maintain communication between fuel handling personnel and the MCR.
Acceptance Criterion i.
Each fuel assembly and control component is installed in the location specified by the design of the initial RXC.
ii.
There is no indication of inadvertent criticality.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-179 Draft Revision 3 RAI 04.06-2 Table 14.2-81a: Control Rod Assembly Ambient Temperature Full-Height Drop Time Test #81A Startup test is required to be performed for each NPM.
This test is performed after initial fuel loading but prior to initial criticality.
Test Objective Verify each CRA satisfies the CRA drop time acceptance criteria for RCS at ambient temperature.
Prerequisites i.
The core is installed.
ii.
The NPM is fully assembled.
iii. The RCS is at ambient temperaturecold temperature conditions.
iv. The nuclear instrumentation system is calibrated and operable.
v.
The SDM is within the limits specified in the core operating limits report.
Test Method i.
Fully withdraw each individual CRA.
ii.
Interrupt the electrical power to the associated CRDM.
iii. Measure the CRA drop time.
Acceptance Criteria i.
Each CRA drop time is within Technical Specification limits.
ii.
Each CRA drop time is within two sigma of the drop time data for all control rods, or has been verified within Technical Specification limits by a minimum of three additional performances of this test.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-181 Draft Revision 3 Table 14.2-83: Initial Criticality Test # 83 Startup test is required to be performed for each NPM.
This test is performed after initial fuel loading.
Test Objective Achieve initial criticality in a controlled manner.
Prerequisites i.
The RCS is at hot zero power (RCS at normal operating pressure and RCS temperature at the maximum temperature obtainable when heated only by the MHS).
ii.
All RCS temperatures satisfy the minimum technical specification temperature for criticality.
iii. The nuclear instrumentation system is calibrated and operable.
iv. The SDM is within the limits specified in the core operating limits report.
v.
An estimated critical position (calculation) has been performed.
vi. RCS measured boron is at or near the desired estimated critical position value.
vii. The shutdown banks and the regulating banks are fully inserted.
viii. A neutron count rate of at least 1/2 counts per second registers on the startup channels, and the signal to noise ratio is greater than 2.
Test Method i.
Shutdown banks are withdrawn in sequence using the sequence of a normal plant startup. Gather data to plot the inverse count rate ratio. The inverse count rate ratio is used to monitor reactivity.
ii.
Once all shutdown banks are fully withdrawn, then the regulating bank is withdrawn using the sequence of a normal plant startup. The inverse count rate ratio is plotted to monitoring reactivity for the approach to criticality.
iii. After criticality is obtained, the regulating bank is confirmed to be above the TS regulating group insertion limit.
iv. Should criticality be reached with the regulating bank below the insertion limit specified by the core operating limits requirement, the limiting condition of operation test exception is invoked. The RCS boron will be increased until the regulating bank is withdrawn sufficiently to meet the insertion limit.
Acceptance Criterion The reactor is critical with the regulating banks above their technical specification insertion limit.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-190 Draft Revision 3 Table 14.2-92: Neutron Monitoring System Power Range Flux Calibration Test # 92 Startup test is required to be performed for each NPM.
This test is performed at approximately 25, 50, 75 and 100 percent reactor thermal power.
Test Objective Calibrate the NMS power range neutron flux signals during power ascension.
Prerequisites i.
The ICIS is operational.
ii.
The NPM is operating in a steady-state condition at the specified power level.
Test Method i.
With the plant at power levels of approximately 25, 50, 75 and 100 percent of reactor thermal power, record the following data:
- power range neutron flux from the ICIS self-powered neutron detectors
- NMS power range (linear power) signal
- heat balance data ii.
Maintain reactor power, TAVG, and pressurizer level constant during data collection.
iii. Calibrate the NMS neutron flux power range (linear power) signal using the recorded data.
Acceptance Criterion The NMS neutron flux power range (linear power) signal has been calibrated.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-192 Draft Revision 3 Table 14.2-94: Reactor Coolant System Flow Calibration Test # 94 Startup test is required to be performed for each NPM.
This test is performed at approximately 25, 50, 75, and 100 percent reactor thermal power.
Test Objective Calibrate the RCS flow instruments during power ascension.
Prerequisites i.
The ICIS is operational.
ii.
The NPM is operating in a steady-state condition at the specified power level.
iii. The nuclear instrumentation system is calibrated and operable.
Test Method i.
With the plant at power levels of approximately 25, 50, 75, and 100 percent of reactor thermal power, record the following data:
- NMS flux power range (linear power) signal
- RCS narrow range hot leg temperature
- RCS narrow range cold leg temperature
- ICIS core inlet and outlet temperature ii.
Maintain reactor power, TAVG, and pressurizer level at steady state during data collection.
iii. Calibrate the RCS flow instruments using the recorded data.
Acceptance Criterion The RCS flow instruments have been calibrated.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-193 Draft Revision 3 Table 14.2-95: Radiation Shield Survey Test # 95 Startup test is required to be performed for each NPM.
This test is performed at approximately 25, 50, and 100 percent reactor thermal power.
Test Objective Verify the adequacy of concrete radiation shields in the RXB designed to protect personnel from radiation originating from sources within the reactor vessel.
Prerequisites i.
Radiation survey instruments are calibrated.
ii.
The NPM is operating in a steady-state condition at the specified power level.
Test Method i.
Measure gamma and neutron radiation dose rates at designated locations at approximately 25, 50, and 100 percent reactor thermal power in accordance with RG 1.69 and ANSI/ANS-6.3.1 (1987, R2007).
ii.
The designated locations are the accessible areas outside permanent concrete radiation shields in the RXB (reference Figure 12.3-1a for the RXB radiation zone map).
Acceptance Criterion Radiation dose rates are consistent with design expectations.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-199 Draft Revision 3 Acceptance Criteria i.
The turbine does not trip.
ii.
The reactor does not trip.
iii. The main steam safety valves do not open.
iv. The turbine does not overspeed.
v.
The plant automatic control systems, with no manual intervention, maintain the following parameters within design limits during and following the transient:The primary and secondary control systems, with no manual intervention, maintain reactor power, reactor coolant system temperatures, pressurizer pressure and level, and SG levels and pressures within acceptable ranges during and following the transient.
a.
Reactor Power b.
RCS temperature c.
Pressurizer pressure d.
Pressurizer level e.
SG superheat f.
SG pressure g.
SG inventory h.
Gland seal temperature i.
CWS basin level j.
SCWS basin level k.
Feedwater heater level l.
Main condenser hotwell level
- m. Main condenser vacuum n.
Outlet temperature of turbine bypass desuperheater vi. Control system response is reviewed and compared to expected performance. Necessary adjustments to the control systems have been made prior to proceeding to the next power plateau.
vii. Water hammer indications a.
Audible indications of water hammer are not observed.
b.
No damage to pipe supports or restraints.
c.
No damage to equipment.
d.
No equipment leakage as a result of the ramp change.
viii. Piping vibration - System specific steady state and transient vibration testing criteria are established by the piping designer. Actual acceptance criteria will depend on the selected test method, but may include:
a.
Limits for stresses calculated based on the observed/measured vibration response of the system.
b.
No permanent deformation or damage is observed in the piping system or supports.
c.
Vibration displacements are not excessive, would not potentially cause the piping to come in contact with surrounding SSC, and are such that the movement of supports and flexible joints is within their allowable limits.
Table 14.2-100: Ramp Change in Load Demand Test # 100 (Continued)
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-203 Draft Revision 3 Table 14.2-103: 100 Percent Load Rejection Test # 103 Startup test is required to be performed for each NPM.
This test is performed at approximately 100 percent reactor thermal power.
Test Objectives i.
Verify the ability of the plant automatic control systems to sustain a 100 percent load rejection from full power.
ii.
Assess the dynamic response of the plant for a 100 percent power load rejection.
Prerequisites i.
The NPM is operating in a steady-state condition at full reactor thermal power.
ii.
The plants electrical distribution system is aligned for normal operation.
iii. The following control systems are in automatic control:Reactor, turbine, and secondary control systems are in automatic mode.
a.
Reactivity control b.
RCS temperature control c.
Pressurizer pressure control d.
Pressurizer level control e.
Turbine control f.
Feedwater level control g.
CWS basin level control h.
SCWS basin level control i.
Feedwater heater level control j.
Hotwell level control Test Method Manually trip the generator output breaker to provide a 100 percent load rejection.
Acceptance Criteria i.
The turbine trips.
ii.
The reactor does not trip.
iii. The main steam safety valves do not open.
iv. The turbine does not overspeed beyond design limits.
v.
The turbine generator bypass valve opens and modulates steam flow to the condenser to maintain steam generator pressure.
vi. The plant automatic control systems, with no manual intervention, maintain the following parameters within design limits during and following the transient:The turbine generator bypass valve opens and modulates steam flow to the condenser to maintain steam generator pressure.
a.
Reactor Power b.
RCS temperature c.
Pressurizer pressure d.
Pressurizer level e.
SG superheat f.
SG inventory g.
Gland seal temperature h.
CWS basin level i.
SCWS basin level j.
Feedwater heater level k.
Main condenser hotwell level l.
Main condenser vacuum
- m. Outlet temperature of turbine bypass desuperheater vi. The FWS automatically provides the necessary feedwater flow to the steam generator.
vii. Water hammer indications a.
Audible indications of water hammer are not observed.
b.
No damage to pipe supports or restraints.
c.
No damage to equipment.
d.
No equipment leakage as a result of the load rejection.
NuScale Final Safety Analysis Report Initial Plant Test Program Tier 2 14.2-208 Draft Revision 3 RAI 14.02-1 Table 14.2-108: NuScale Power Module Vibration Test # 108 This startup test is required to be performed once for NPM #1. This test supports FOAK testing described in Section 14.2.3.3.
This test is performed at 100 percent reactor thermal power. NuScale Power Module vibration testing is described in Sections 3.9.2.1.1.1, 3.9.2.3, and 3.9.2.4;. and Reference 3.9-5 NuScale Power, LLC, Comprehensive Vibration Assessment Program (CVAP) Technical Report, TR-0716-50439, Revision 1, and NuScale Comprehensive Vibration Assessment Program Measurement and Inspection Plan Technical Report, TR-0918-60894, Revision 0.
Test Objective for NPM #1 i.
Perform vibration testing of DHRS steam piping at 100 percent reactor thermal power as described in TR-0716-50439, Section 4.3, to verify vibration amplitudes in the DHRS steam piping confirm the acoustic resonance analysis results described in TR-0716-50439 Section 4.3.
ii.
Perform visual examination of the NuScale Power Module components specified in Table 5-1 of TR-0716-50439.
Prerequisites i.
The DHRS steam piping is instrumented to obtain acoustic resonance (AR) data.
Test Method i.
Operate the NuScale Power Module for a sufficient duration at 100 percent power to ensure one million vibration cycles for the component with the lowest structural natural frequency.
ii.
Monitor the vibration of the DHRS steam piping. If an unacceptable vibration response develops any time during initial startup testing, the test conditions will be adjusted to stop the vibration and the reason for the vibration anomaly will be investigated prior to continuing with the testing.
iii. Disassemble the NuScale Power Module and performed a visual examination of the module components specified in Table 5-1 of TR-0716-50439.
Acceptance Criteria i.
Measured vibration amplitudes in the DHRS steam piping confirm the acoustic resonance analysis results described in TR-0716-50439 Section 4.3.
ii.
Visual examination results of module components satisfy the acceptance criteria of Table 5-1 of TR-0716-50439.
NuScale Final Safety Analysis Report Certified Design Material and Inspections, Tests, Analyses, and Acceptance Criteria Tier 2 14.3-70 Draft Revision 3 03.08.02 PL Section 9.5.3 discusses the PLS which provides emergency illumination of the operator workstations and SDIS panels in the MCR and operator workstations in the RSS.
In accordance with Table 14.2-60, a preoperational test demonstrates that the PLS provides at least:
i.
10 foot-candles of illumination at the MCR operator workstations and MCR auxiliary panels.
ii.
10 foot-candles at the RSS operator workstations.
X X
03.08.03 PL Section 9.5.3 discusses the use of eight-hour battery pack emergency lighting fixtures, which provide illumination of at least one foot-candle for post-fire safe shutdown activities outside of the MCR and RSS in accordance with NFPA 804. These units should provide lighting for:
- areas required for power restoration / recovery to comply with the guidance of RG 1.189, Fire Protection for Nuclear Power Plants.
- areas where normal actions are required for operation of equipment needed during fire; and
- escape or access routes for firefighting and the remote shutdown area.
In accordance with the requirements in Table 14.2-60, a preoperational test demonstrates that eight-hour battery pack emergency lighting fixtures illuminate their required target areas to provide at least one foot-candle illumination in the areas outside the MCR or RSS where post-fire safe-shutdown activities are performed.
X X
Table 14.3-2: Shared/Common Structures, Systems, and Components and Non-Structures, Systems, and components Based Design Features and Inspections, Tests, Analyses, and Acceptance Criteria Cross Reference(1) (Continued)
ITAAC No.
System Discussion DBA Internal/External Hazard Radiological PRA & Severe Accident FP