3I-1 Revision 0 Turkey Point Units 6 & 7 - IFSAR Appendix 3I Evaluation for High Frequency Seismic Input 3I.1 Introduction The seismic analysis and design of the AP1000 plant is based on the Certified Seismic Design Response Spectra (CSDRS) shown in Subsection 3.7.1.1. These spectra are based on Regulatory Guide 1.60 with an increase in the 25 hertz region. Ground Motion Response Spectra (GMRS) for some Central and Eastern United States rock sites show higher amplitude at high frequency than the CSDRS. Evaluations are described in this appendix for an envelope response spectra with high frequency for the seismic input. The resulting spectra of this site are shown in Figure 3I.1-1 and Figure 3I.1-2 and compare this hard rock high frequency (HRHF) envelope response spectra at the foundation level against the AP1000 CSDRS for both the horizontal and vertical directions for 5%

damping. The HRHF envelope response spectra exceed the CSDRS for frequencies above about 15 Hz.

High frequency seismic input is generally considered to be non-damaging as described in Reference 1. The evaluation of the AP1000 nuclear island for the high frequency input is based on the analysis of a limited sample of structures, components, supports, and piping to demonstrate that the high frequency seismic response is non-damaging. The evaluation includes building structures, reactor pressure vessel and internals, primary component supports, primary loop nozzles, piping, and equipment.

This appendix describes the methodology and criteria used in the evaluation to confirm that the high frequency input is not damaging to equipment and structures qualified by analysis for the AP1000 CSDRS. It provides supplemental criteria for selection and testing of equipment whose function might be sensitive to high frequency. The results of the high frequency evaluation demonstrating that the AP1000 plant is qualified for this type of input are documented in a technical report (Reference 2).

This report will provide a summary of the analysis and test results.

3I.2 High Frequency Seismic Input Presented in Figures 3I.1-1 and 3I.1-2 is a comparison of the horizontal and vertical HRHF envelope response spectra and the AP1000 CSDRS. The HRHF envelope response spectra presented are calculated at foundation level (39.5' below grade), at the upper most competent material and treated as an outcrop for calculation purposes.

For each direction, the HRHF envelope response spectra exceed the design spectra in higher frequencies (greater than 15 Hz horizontal and 20 Hz vertical). The spectra are used for the HRHF envelope response spectra. If necessary, the HRHF envelope response spectra are enhanced at low frequencies so that HRHF envelope response spectra fully envelope all of the hard rock sites.

These HRHF envelope response spectra are further limited in that the shear wave velocity limitation is defined at the bottom of the basemat equal to or higher than 7,500 fps, while maintaining a shear wave velocity equal to or above 8,000 fps at the lower depths.

3I.3 NI Models Used To Develop High Frequency Response The NI20 nuclear island model described in Appendix 3G is analyzed in ACS SASSI using the HRHF time histories applied at foundation level to obtain the motion at the base.

A modal analysis of the NI05 model for both the auxiliary and shield buildings and containment internal structure (CIS) has been performed for each of these regions. Specific areas within each wall or floor where out-of-plane modes, which may respond to either CSDRS or HRHF input (including structures with modes less than 33 Hz and between 33 Hz to 50 Hz), have been identified. The

3I-2 Revision 0 Turkey Point Units 6 & 7 - IFSAR survey reveals that some regions, typically in the middle of a floor or wall, exhibit amplified behavior compared to the critical nodes at the corner and edge building locations. The amplified FRS for these regions is generated in addition to the typical set of critical nodes for building analysis by a single time history analysis of the NI05 building model subject to the HRHF time history input. Seismic response spectra for each of the flexible nodes are considered when selecting the pre-existing group spectra, which is the envelope of the entire floor in that area.

Evaluation of incoherent HRHF spectra has been performed. The CSDRS and HRHF seismic responses were compared with coherent and incoherent considerations at a number of locations in the nuclear island. There are some exceedances, mostly above the 15 hertz region, and these are typical of the plant comparative responses. The steel containment vessel (SCV) was excluded from the evaluation because the HRHF spectra at the base of the SCV are enveloped by the AP1000 CSDRS spectra at the base of the SCV.

Structures designed to the CSDRS input are adequately designed for the HRHF input because the HRHF coherent results are enveloped by the CSDRS results.

3I.4 Evaluation Methodology The demonstration that the AP1000 nuclear power plant is qualified for the high frequency seismic response does not require the analysis of the total plant. The evaluations made are of representative systems, structures, and components, selected by screening, as potentially sensitive to high frequency input in locations where there were exceedances in the high frequency region.

Acceptability of this sample is considered sufficient to demonstrate that the AP1000 is qualified.

The high frequency seismic analyses that are performed use time history or broadened response spectra. The analysis is not performed using the combination spectra of the CSDRS and the HRHF envelope response spectra. Separate analyses with each spectra are used.

The high frequency seismic analyses used the soil-structure interaction code ACS SASSI. The results presented in this report are based on the stochastic (multiple, statistical analyses) seismic incoherent soil-structure interaction analysis approach referred herein as the simulation approach.

The evaluations performed assess the ability of the system, structure, or component to maintain its safety function.

Supplementary analyses are performed as needed to show that high frequency floor response spectra exceedances are not damaging. These analyses can include: gap nonlinearities; material inelastic behavior; multi point response spectra analyses where the high frequency response excites a local part of the system. Tests on equipment are specified as needed where function cannot be demonstrated by analysis, or analysis is not appropriate.

3I.5 General Selection Screening Criteria The following general screening criteria are used to identify representative AP1000 systems, structures, and components (SSCs) for the samples to be evaluated to demonstrate acceptability of the AP1000 nuclear power plant for the high frequency motion.

Select systems, structures, and components based on their importance to safety. This includes the review of component safety function for the SSE event and its potential failure modes due to an SSE. Those components whose failure modes would result in safe shutdown are excluded.

3I-3 Revision 0 Turkey Point Units 6 & 7 - IFSAR

Select systems, structures, and components that are located in areas of the plant that experience large high frequency seismic response.

Select systems, structures, and components that have significant modal response within the region of high frequency amplification. Significance is defined by such items as modal mass; participation factor, stress and/or deflection.

Select systems, structures, and components that have significant stress as compared to allowable when considering load combinations that include seismic.

3I.6 Evaluation In this section the portions of structures, the components, and the systems that are evaluated for the high frequency seismic response are identified. The sample to be evaluated, based on the screening criteria applicable to the SSCs consists of the following:

Building Structures Auxiliary Building - 3 locations Shield Building - 8 locations CIS - 2 locations

Primary Coolant Loop Reactor Vessel and Internals Primary Component Supports Reactor Coolant Loop Primary Equipment Nozzles

Piping Systems - ASME Class 1, 2, and 3 piping systems will be evaluated for the HRHF GMRS. This evaluation is within the scope of the piping DAC (see COL Information Item 3.9-7).

Electro-Mechanical Equipment - Equipment that is potentially sensitive to high frequency input (see Table 3I.6-1)

These structures, systems, and equipment are discussed in more detail in the sections that follow.

3I.6.1 Building Structures Maintaining the NI buildings structural integrity is important to the safety of the plant. Representative portions of the buildings that are evaluated for the effect of high frequency input are selected based on those areas that can experience high seismic shear and moment loads due to the seismic event.

Areas chosen are at the base of the shield building, in the vicinity of auxiliary building floors that have fundamental frequencies in the high frequency region, and the corners of the auxiliary building. Three locations are selected on the auxiliary building that reflect the bottom of a wall where the shear and moment would be large, a wall in the vicinity of a floor that is influenced by high frequency response, and a corner intersection of walls. Eight locations are evaluated on the shield building. Four at elevation 107' and four at elevation 211'. These locations are located on the east, west, north and south sides. The south-west wall of the refueling canal is evaluated since it is a representative wall on

3I-4 Revision 0 Turkey Point Units 6 & 7 - IFSAR the refueling canal. The CA02 wall in the CIS building is evaluated since it is a representative wall associated with the IRWST.

The evaluation consists of a comparison of the loads from the high frequency input to those obtained from the AP1000 design spectra, shown in Figures 3I.1-1 and 3I.1-2, for these representative building structures. The NI building structures are considered qualified for the high frequency input if the seismic loads from the Regulatory Guide 1.60 (modified) envelope those from the high frequency input. If there is any exceedance, this is evaluated further to confirm that the existing design is adequate.

3I.6.2 Primary Coolant Loop A failure within the reactor coolant loop could challenge the integrity of the reactor coolant pressure boundary. Therefore, it is chosen for evaluation. The components evaluated are as follows:

Reactor vessel and internals

Reactor vessel supports

Steam generator supports

Reactor coolant loop primary equipment nozzles The reactor vessel and internals are selected since they are important to safety and their analysis is representative of major primary components. The building structure below the reactor vessel supports is fairly stiff and there may be significant vertical amplification at the supports of the reactor pressure vessel. Further, reactor vessel internals have relatively complex structural systems including gap nonlinearities and sliding elements. Also, they may be sensitive to high frequency input as summarized below:

Vertical and horizontal modes of the upper internals and the reactor vessel modes are in the relatively high frequency range.

Additional high frequencies are associated with nonlinear impact The evaluation consists of a comparison of the loads from the high frequency input to those obtained from the Regulatory Guide 1.60 (modified) input. Qualification is shown for the high frequency input if the seismic loads from the Regulatory Guide 1.60 (modified) envelope those from the high frequency input. If there is exceedance, then comparison is made for the combination of the seismic with the design basis pipe break loads and steady state loads. Qualification is then shown if the high frequency loads are relatively insignificant compared to the other loads, or there are no required design changes.

Maintaining the integrity of the reactor vessel and steam generator supports is important to preserving the primary component safety function. They are representative of supports on components, and see high loads.

The reactor coolant loop nozzles at the cold and hot leg interfaces of the reactor pressure vessel, reactor coolant pumps, and steam generators are important to include in the evaluation since these are critical areas of components.

The evaluation of the primary component supports and reactor coolant loop nozzles consists of a comparison of the loads from the high frequency input to those obtained from the Regulatory Guide 1.60 (modified) input. These items are considered qualified for the high frequency input if the seismic loads from the Regulatory Guide 1.60 (modified) envelope those from the high frequency input. If there is any exceedance, then an evaluation is made combining the high frequency loads with the other load components (e.g., thermal, pressure, dead) and a comparison made to the design loads. If

3I-5 Revision 0 Turkey Point Units 6 & 7 - IFSAR the design loads envelope the load combinations that include the high frequency seismic input, then the nozzles and supports are considered qualified for the high frequency input.

3I.6.3 Piping Systems ASME Class 1, 2, and 3 piping systems will be evaluated for the HRHF GMRS. This evaluation is within the scope of the piping DAC (see COL Information Item 3.9-7).

3I.6.4 Electrical and Electro-Mechanical Equipment The groups of safety-related equipment considered for evaluation are those that may be sensitive to the high frequency input. This includes those cabinet-mounted equipment, field sensors, and appurtenants that may be sensitive to high frequency seismic inputs identified in Table 3I.6-1.

Sample safety-related cabinets have been identified that are typically sensitive to seismic input.

Evaluations were performed to verify these cabinets do not have excessive seismic excitation on their mounted equipment, the cabinet designs do not require changes due to the high frequency input, and the cabinets will maintain their structural integrity during the high frequency input. Time history analyses of these cabinets were performed for both the Regulatory Guide 1.60 (modified) and the high frequency inputs so that comparisons can be made to their seismic response from both seismic inputs. This analytical study reported in APP-GW-GLR-115 (Reference 2) concluded that safety-related equipment may be screened.

The AP1000 HRHF screening program for determination and evaluation of potential high frequency sensitive equipment is in compliance with the NRC requirements in Section 4.0, Identification and Evaluation of HF Sensitive Mechanical and Electrical Equipment/Components, of COL/DC-ISG-1 (Reference 3). The AP1000 HRHF screening program is also consistent with the guidelines developed as part of an industry review document in the EPRI White Paper, Seismic Screening of Components Sensitive to High Frequency Vibratory Motions (Reference 4), transmitted to the NRC on June 28, 2007, for determining the safety-related equipment and components that may be HRHF sensitive, and screening procedures to ensure that any safety-related equipment and components sensitive to HRHF seismic excitation are screened out. This industry review of HF exceedance and further evaluations of SSCs performed by Westinghouse concluded that HRHF envelope response spectra are less harmful than the CSDRS except for the functionality of potential HRHF-sensitive components.

The AP1000 HRHF screening program is based on an HF evaluation study reported in APP-GW-GLR-115 (Reference 2). The HF evaluation study concluded that AP1000 In-Structure Response Spectra (ISRS) developed from the AP1000 CSDRS would, in the majority of cases, produce equipment stress results of the same magnitude or higher than the stress results produced from HRHF seismic excitation. The exception to this condition is when the dominant natural frequency of the equipment is in the HRHF exceedance range and there can be significantly more response because the frequency coincides with the input driving force. Under this condition, forces/

stresses generated in the equipment could be due to the acceleration exceedance; therefore, the equipment will be subjected to HRHF seismic evaluation/testing to screen out equipment by verifying its performance and acceptability under HRHF excitation. Review of seismic test data for electrical and microprocessor based cabinets performed to generic and high frequency excitation concluded that seismic testing that peaks in the lower frequency range will produce larger displacements and velocities, and will result in higher stresses in the equipment.

The goal of the AP1000 HRHF screening program is to identify the potential safety-related equipment and components that have the potential to be HRHF-sensitive and show them to be acceptable for their specific application (screened-out). The AP1000 HRHF screening program is a two step process. The first step is an HRHF susceptibility review to identify potential high frequency sensitive

3I-6 Revision 0 Turkey Point Units 6 & 7 - IFSAR safety-related equipment. The second step is the screened-out equipment process to demonstrate its acceptability for the HRHF seismic excitation. Evaluation of screened-in equipment as defined in COL/DC-ISG-1 (Reference 3) is not performed because all safety-related equipment that is screened-in will be eliminated or shown to be acceptable through a design change process.

For the AP1000 HRHF screening program, the following conditions must exist:

1.

Plant-specific HRHF GMRS exceeds the AP1000 CSDRS in the high frequency range at 5% critical damping.

2.

Safety-related equipment has potential failure modes involving change of state, chatter, signal change/drift, and connection problems.

Table 3I.6-2 is a list of potential HRHF-sensitive AP1000 safety-related equipment developed based on Table 3.11-1 of Section 3.11, Environmental Qualification of Mechanical and Electrical Equipment. The equipment in Table 3.2-3 of Section 3.2, AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment, and Table 3I.6-3 is not HRHF-sensitive. The structural integrity and operability of equipment in Table 3.2-3 and Table 3I.6-3 will not be impacted by the high frequency excitation.

The HRHF susceptibility review of AP1000 safety-related equipment is not performed for potential failure modes associated with mounting, connections, fasteners, joints, and structural interface.

These potential failure modes are addressed through the seismic qualification of the safety-related equipment to the AP1000 ISRS testing performed in compliance with IEEE Standard 344-1987. The AP1000 ISRS qualification testing generates higher displacements and velocities than those resulting from HRHF seismic excitation since the AP1000 ISRS is controlled by the lower frequency range. The higher displacement, velocities, and accelerations will detect these equipment structural failure modes if they exist.

At locations where HRHF response spectra show exceedance of the CSDRS and there is a likelihood of equipment damage, further evaluations would be performed to verify that the existing qualification is adequate for equipment not high frequency sensitive, as listed in Table 3I.6-3, under the following conditions:

Safety-related equipment must have modes or natural frequencies in the range of interest.

Evaluation will apply the same acceptance criteria and methodologies used in CSDRS qualification.

To demonstrate acceptability for both CSDRS and HRHF testing, the test response spectra must envelop the CSDRS and HRHF spectra, respectively, with margin over the frequency range of interest in compliance with IEEE Standard 344-1987. In the event that the CSDRS and/or HRHF response spectra would be revised after the qualification program has been completed, a reconciliation effort would be performed to verify that the CSDRS and HRHF testing is still valid. The reconciliation effort may result in requalification activities and qualification documentation revisions.

High Frequency Screening Process - Step 1 The potential failure modes of high frequency sensitive component types and assemblies are important considerations in the high frequency program. The following are potential failure modes of high frequency sensitive components/equipment:

Inadvertent change of state

Chatter

Change in accuracy and drift in output signal or set-point

3I-7 Revision 0 Turkey Point Units 6 & 7 - IFSAR

Electrical connection failure or intermediacy (e.g., poor quality solder joints)

Mechanical connection failure

Mechanical misalignment/binding (e.g., latches, plungers)

Fatigue failure (e.g., solder joints, ceramics, self-taping screws, spot welds)

Improperly and unrestrained mounted components

Inadequately secured/locked mechanical fasteners and connections Components and equipment determined to have potential failure modes involve change of state, chatter, signal change/drift, and connection problems will be demonstrated to be acceptable through the performance of a supplemental high frequency screening test. Those high frequency sensitive components having failure modes associated with mounting, connections and fasteners, joints, and interface are considered to be acceptable as a result of the AP1000 ISRS qualification testing per IEEE Standard 344-1987 and/or require quality assurance inspection and process/design controls.

High Frequency Screening Process - Step 2 The HRHF susceptibility review is to verify that the subject equipment is capable of performing its safety-related function under HRHF seismic excitation. All AP1000 safety-related equipment will be qualified to the AP1000 ISRS, and the dominant natural frequencies of the equipment will be determined. The EPRI White Paper (Reference 4) identifies the following three evaluation methods to demonstrate that potential HRHF-sensitive safety-related equipment is not HRHF vulnerable:

1.

Existing seismic qualification test data for potential high frequency sensitive equipment should be reviewed for applicability and adequacy of the test method to demonstrate sufficient high frequency content.

2.

Systems/circuits containing potentially sensitive items should be reviewed for inappropriate/

unacceptable system actions due to assumed change of state, contact chatter/intermittency, set point drifts, or loss of calibration.

3.

HRHF vibration screening test is conducted to identify any HRHF sensitivities/abnormalities of the components. Several conventional test methods are recommended.

The first and third evaluation methods are part of the AP1000 HRHF screening program and are further detailed below. The AP1000 HRHF seismic screening evaluation will employ the AP1000 HRHF SSE response spectra as input in verifying potential HF sensitive safety-related equipment is not vulnerable to HRHF seismic excitation. Additional seismic test margin will be introduced into the HRHF seismic screening evaluation as needed.

Method 1: Review of Seismic Test Data Available seismic test data can be used for AP1000 HRHF plant applications when:

Seismic qualification testing performed on potential HRHF-sensitive safety-related equipment meets as a minimum the AP1000 ISRS in compliance with IEEE Standard 344-1987.

Safe shutdown earthquake (SSE) test had sufficient energy content in the HRHF region to verify that the safety-related equipment is not vulnerable to HRHF seismic excitation.

No additional seismic testing is required for safety-related equipment previously tested and whose qualification level envelops the HRHF required response spectra (RRS).

IEEE Standard 344-1987 provides guidance to ensure that the seismic test input is generated and in compliance with the frequency range of interest. To demonstrate acceptability for frequency content, it is necessary to show that the frequency content of the test waveform is at least as broad as the

3I-8 Revision 0 Turkey Point Units 6 & 7 - IFSAR frequency content of the amplified region of the RRS except at the low frequencies where non-enveloping is permitted under certain conditions (refer to IEEE Standard 344-1987 subclauses 7.6.3.1(10) and 7.6.3.1(13)). An evaluation of the test input waveform should be conducted per IEEE Standard 344-1987 Annex B to verify the test data has sufficient content over the frequency range of interest throughout the input time history. If an evaluation of the test input is performed, and the data demonstrates sufficient frequency content in the high frequency range throughout the time history, then the data is acceptable.

Method 3: HRHF Screening Test The HRHF screening test is a supplemental test to the required seismic qualification methods performed in accordance with IEEE Standard 344-1987 for those plants that have high frequency exceedance of the AP1000 CSDRS. The purpose of the HRHF screening test is to demonstrate that the potential HRHF-sensitive safety-related equipment will perform its safety-related function as required under HRHF seismic excitation. The HRHF screening test is performed in conjunction with the AP1000 ISRS seismic qualification testing, or it is performed as a supplemental test after completion of the AP1000 ISRS seismic qualification testing. The AP1000 ISRS and HRHF test input time histories have 30-second durations with frequency content up to the cutoff frequency developed in accordance with subclause 7.6.3 (Multiple-Frequency Tests) and Annex B (Frequency Content and Stationarity) of IEEE Standard 344-1987. During the AP1000 ISRS and HRHF testing, the equipment will be functional and monitored to verify the safety-related function was demonstrated. Screening testing will be performed using HRHF response spectra as defined in the EPRI White Paper (Reference 4) when AP1000 HRHF inputs are not available. The HRHF response spectra will be generated based on the 5g and 15g peak spectral acceleration at 5% critical damping in the 25 Hz to 50 Hz frequency range. If the HRHF screening test cannot demonstrate the equipment to be acceptable, then the safety-related equipment will be removed or modified and additional testing or justification will be required.

The AP1000 safety-related equipment will be seismic qualified to the AP1000 ISRS associated with the mounting location of the equipment as a minimum. Seismic qualification testing will consist of five AP1000 ISRS operating basis earthquakes (OBEs) followed by one SSE as a minimum. The OBE level will be at least one-half the SSE level. The OBE testing is used to vibration age and address low-cycle fatigue of equipment prior to SSE testing. Cyclic fatiguing of equipment for HRHF exceedance area is adequately addressed by performing five OBE (one-half the SSE) and a minimum of one SSE seismic test runs in compliance with IEEE Standard 344-1987 prior to performing the supplemental HRHF screening test. Additional OBE testing in the high frequency exceedance range is adequately addressed by the demonstration that the peak stress cycles required for five one-half SSE events using the AP1000 HRHF ISRS are equivalent to or enveloped by the peak stress cycles resulting from five one-half SSE events and one full SSE event using the AP1000 CSD ISRS.

The test results of AP1000 seismic qualification programs with multiple operational states (for example, relays have three possible operational states: de-energized, energized, and change of state) will be used to determine the most sensitive equipment electrical operational state. The HRHF test run is performed on the equipment in its most sensitive electrical operational state to demonstrate its safety-related function under HRHF seismic excitation. If this is not possible, additional HRHF screening tests will be performed as needed to address the other most sensitive electrical operation states.

3I.7 References 1.

EPRI Draft White Paper, Considerations for NPP Equipment and Structures Subjected to Response Levels Caused by High Frequency Ground Motions, Transmitted to NRC March 19, 2007.

3I-9 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.

APP-GW-GLR-115, Effect of High Frequency Seismic Content on SSCs, Westinghouse Electric Company LLC.

3.

COL/DC-ISG-1, Interim Staff Guidance on Seismic Issues of High Frequency Ground Motion, May 19, 2008.

4.

EPRI White Paper, Seismic Screening of Components Sensitive to High Frequency Vibratory Motions, June 2007.

5.

Letter, R. Sisk (Westinghouse) to NRC, AP1000 Response to Request for Additional Information (SRP3.10), DCP/NRC2280, October 17, 2008.

3I-10 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3I.6-1 Potential High Frequency Sensitive Equipment List Equipment or components with moving parts and required to perform a switching function during the seismic event (e.g., circuit breakers, contactors, auxiliary switches, molded case circuit breakers, motor control center starters, and pneumatic control assemblies)

Components with moving parts that may bounce or chatter such as relays and actuation devices (e.g., shunt trips)

Unrestrained components Potentiometers Process switches and sensors (e.g., pressure/differential pressure, temperature, level, limit/position, and flow)

Components with accuracy requirements that may drift due to seismic loading Interfaces such as secondary contacts

- Connectors and connections (including circuit board connections for digital and analog equipment)

3I-11 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3I.6-2 (Sheet 1 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number Batteries IDSA 125V 60 Cell Battery 1A IDSA-DB-1A IDSA 125V 60 Cell Battery 1B IDSA-DB-1B IDSB 125V 60 Cell Battery 1A IDSB-DB-1A IDSB 125V 60 Cell Battery 1B IDSB-DB-1B IDSB 125V 60 Cell Battery 2A IDSB-DB-2A IDSB 125V 60 Cell Battery 2B IDSB-DB-2B IDSC 125V 60 Cell Battery 1A IDSC-DB-1A IDSC 125V 60 Cell Battery 1B IDSC-DB-1B IDSC 125V 60 Cell Battery 2A IDSC-DB-2A IDSC 125V 60 Cell Battery 2B IDSC-DB-2B IDSD 125V 60 Cell Battery 1A IDSD-DB-1A IDSD 125V 60 Cell Battery 1B IDSD-DB-1B Spare 125V 60 Cell Battery 1A IDSS-DB-1A Spare 125V 60 Cell Battery 1B IDSS-DB-1B Battery Chargers IDSA Battery Charger IDSA-DC-1 IDSB Battery Charger IDSB-DC-1 IDSB Battery Charger 2 IDSB-DC-2 IDSC Battery Charger 1 IDSC-DC-1 IDSC Battery Charger 2 IDSC-DC-2 IDSD Battery Charger IDSD-DC-1 Spare Battery Charger IDSS-DC-1

3I-12 Revision 0 Turkey Point Units 6 & 7 - IFSAR Distribution Panels IDSA 250 Vdc Dist Panel IDSA-DD-1 IDSB 250 Vdc Dist Panel IDSB-DD-1 IDSC 250 Vdc Dist Panel IDSC-DD-1 IDSD 250 Vdc Dist Panel IDSD-DD-1 IDSA 120 Vac Dist Panel 1 IDSA-EA-1 IDSA 120 Vac Dist Panel 2 IDSA-EA-2 IDSB 120 Vac Dist Panel 1 IDSB-EA-1 IDSB 120 Vac Dist Panel 2 IDSB-EA-2 IDSB 120 Vac Dist Panel 3 IDSB-EA-3 IDSC 120 Vac Dist Panel 1 IDSC-EA-1 IDSC 120 Vac Dist Panel 2 IDSC-EA-2 IDSC 120 Vac Dist Panel 3 IDSC-EA-3 IDSD 120 Vac Dist Panel 1 IDSD-EA-1 IDSD 120 Vac Dist Panel 2 IDSD-EA-2 Fuse Panels IDSA Fuse Panel IDSA-EA-4 IDSB Fuse Panel IDSB-EA-4 IDSB Fuse Panel IDSB-EA-5 IDSB Fuse Panel IDSB-EA-6 IDSC Fuse Panel IDSC-EA-4 IDSC Fuse Panel IDSC-EA-5 IDSC Fuse Panel IDSC-EA-6 IDSD Fuse Panel IDSD-EA-4 Table 3I.6-2 (Sheet 2 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-13 Revision 0 Turkey Point Units 6 & 7 - IFSAR Transfer Switches IDSA Fused Transfer Switch Box 1 IDSA-DF-1 IDSB Fused Transfer Switch Box 1 IDSB-DF-1 IDSB Fused Transfer Switch Box 2 IDSB-DF-2 IDSC Fused Transfer Switch Box 1 IDSC-DF-1 IDSC Fused Transfer Switch Box 2 IDSC-DF-2 IDSD Fused Transfer Switch Box 1 IDSD-DF-1 IDSS Fused Transfer Switch Box 1 IDSS-DF-1 Spare Battery 125/250 Vdc Disconnect Switch IDSS-SW-1 IDSS Spare Termination Box IDSS-DF-2 IDSS Spare Termination Box IDSS-DF-3 IDSS Spare Termination Box IDSS-DF-4 IDSS Spare Termination Box IDSS-DF-5 IDSS Spare Termination Box IDSS-DF-6 Motor Control Centers IDSA 250 Vdc MCC IDSA-DK-1 IDSB 250 Vdc MCC IDSB-DK-1 IDSC 250 Vdc MCC IDSC-DK-1 IDSD 250 Vdc MCC IDSD-DK-1 Switchboards IDSA 250 Vdc Switchboard 1 IDSA-DS-1 IDSB 250 Vdc Switchboard 1 IDSB-DS-1 IDSB 250 Vdc Switchboard 2 IDSB-DS-2 IDSC 250 Vdc Switchboard 1 IDSC-DS-1 IDSC 250 Vdc Switchboard 2 IDSC-DS-2 IDSD 250 Vdc Switchboard 1 IDSD-DS-1 Table 3I.6-2 (Sheet 3 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-14 Revision 0 Turkey Point Units 6 & 7 - IFSAR Transformers IDSA Regulating Transformer 1 IDSA-DT-1 IDSB Regulating Transformer 1 IDSB-DT-1 IDSC Regulating Transformer 1 IDSC-DT-1 IDSD Regulating Transformer 1 IDSD-DT-1 Inverters IDSA Inverter IDSA-DU-1 IDSB Inverter 1 IDSB-DU-1 IDSB Inverter 2 IDSB-DU-2 IDSC Inverter 1 IDSC-DU-1 IDSC Inverter 2 IDSC-DU-2 IDSD Inverter IDSD-DU-1 Switchgear RCP 1A 6900V Switchgear 31 ECS-ES-31 RCP 1A 6900V Switchgear 32 ECS-ES-32 RCP 2A 6900V Switchgear 51 ECS-ES-51 RCP 2A 6900V Switchgear 52 ECS-ES-52 RCP 1B 6900V Switchgear 41 ECS-ES-41 RCP 1B 6900V Switchgear 42 ECS-ES-42 RCP 2B 6900V Switchgear 61 ECS-ES-61 RCP 2B 6900V Switchgear 62 ECS-ES-62 Reactor Trip Switchgear PMS-JD-RTSA01 Reactor Trip Switchgear PMS-JD-RTSA02 Reactor Trip Switchgear PMS-JD-RTSB01 Reactor Trip Switchgear PMS-JD-RTSB02 Table 3I.6-2 (Sheet 4 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-15 Revision 0 Turkey Point Units 6 & 7 - IFSAR Reactor Trip Switchgear PMS-JD-RTSC01 Reactor Trip Switchgear PMS-JD-RTSC02 Reactor Trip Switchgear PMS-JD-RTSD01 Reactor Trip Switchgear PMS-JD-RTSD02 Level Switches Core Makeup Tank A Narrow Range PXS-JE-LS011A Core Makeup Tank A Narrow Range PXS-JE-LS011B Core Makeup Tank A Narrow Range PXS-JE-LS011C Core Makeup Tank A Narrow Range PXS-JE-LS011D Core Makeup Tank B Narrow Range PXS-JE-LS012A Core Makeup Tank B Narrow Range PXS-JE-LS012B Core Makeup Tank B Narrow Range PXS-JE-LS012C Core Makeup Tank B Narrow Range PXS-JE-LS012D Core Makeup Tank A Narrow Range PXS-JE-LS013A Core Makeup Tank A Narrow Range PXS-JE-LS013B Core Makeup Tank A Narrow Range PXS-JE-LS013C Core Makeup Tank A Narrow Range PXS-JE-LS013D Core Makeup Tank B Narrow Range PXS-JE-LS014A Core Makeup Tank B Narrow Range PXS-JE-LS014B Core Makeup Tank B Narrow Range PXS-JE-LS014C Core Makeup Tank B Narrow Range PXS-JE-LS014D Containment Floodup Level PXS-JE-LS050 Containment Floodup Level PXS-JE-LS051 Containment Floodup Level PXS-JE-LS052 Table 3I.6-2 (Sheet 5 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-16 Revision 0 Turkey Point Units 6 & 7 - IFSAR Neutron Detectors Source Range Neutron Detector RXS-JE-NE001A Source Range Neutron Detector RXS-JE-NE001B Source Range Neutron Detector RXS-JE-NE001C Source Range Neutron Detector RXS-JE-NE001D Intermediate Range Neutron Detector RXS-JE-NE002A Intermediate Range Neutron Detector RXS-JE-NE002B Intermediate Range Neutron Detector RXS-JE-NE002C Intermediate Range Neutron Detector RXS-JE-NE002D Power Range Neutron Detector (Lower)

RXS-JE-NE003A Power Range Neutron Detector (Lower)

RXS-JE-NE003B Power Range Neutron Detector (Lower)

RXS-JE-NE003C Power Range Neutron Detector (Lower)

RXS-JE-NE003D Power Range Neutron Detector (Upper)

RXS-JE-NE004A Power Range Neutron Detector (Upper)

RXS-JE-NE004B Power Range Neutron Detector (Upper)

RXS-JE-NE004C Power Range Neutron Detector (Upper)

RXS-JE-NE004D Radiation Monitors Containment High Range Area Monitor PXS-JE-RE160 Containment High Range Area Monitor PXS-JE-RE161 Containment High Range Area Monitor PXS-JE-RE162 Containment High Range Area Monitor PXS-JE-RE163 Control Room Supply Air Area Monitor VBS-JE-RE001A Control Room Supply Air Area Monitor VBS-JE-RE001B Table 3I.6-2 (Sheet 6 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-17 Revision 0 Turkey Point Units 6 & 7 - IFSAR Speed Sensors RCP 1A Pump Speed RCS-JE-ST281 RCP 1B Pump Speed RCS-JE-ST282 RCP 2A Pump Speed RCS-JE-ST283 RCP 2B Pump Speed RCS-JE-ST284 Transmitters PCS Water Delivery Flow PCS-JE-FT001 PCS Water Delivery Flow PCS-JE-FT002 PCS Water Delivery Flow PCS-JE-FT003 PCS Water Delivery Flow PCS-JE-FT004 PCS Storage Tank Water Level PCS-JE-LT010 PCS Storage Tank Water Level PCS-JE-LT011 PRHR HX Flow PXS-JE-FT049A PRHR HX Flow PXS-JE-FT049B RCS Hot Leg 1 Flow RCS-JE-FT101A RCS Hot Leg 1 Flow RCS-JE-FT101B RCS Hot Leg 1 Flow RCS-JE-FT101C RCS Hot Leg 1 Flow RCS-JE-FT101D RCS Hot Leg 2 Flow RCS-JE-FT102A RCS Hot Leg 2 Flow RCS-JE-FT102B RCS Hot Leg 2 Flow RCS-JE-FT102C RCS Hot Leg 2 Flow RCS-JE-FT102D SG1 Startup Feedwater Flow SGS-JE-FT055A SG1 Startup Feedwater Flow SGS-JE-FT055B SG2 Startup Feedwater Flow SGS-JE-FT-056A Table 3I.6-2 (Sheet 7 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-18 Revision 0 Turkey Point Units 6 & 7 - IFSAR SG2 Startup Feedwater Flow SGS-JE-FT056B MCR Air Delivery Line Flow Rate - A VES-JE-FT003A MCR Air Delivery Line Flow Rate - B VES-JE-FT003B Plant Vent Flow VFS-JE-FT101 IRWST Level PXS-JE-LT045 IRWST Level PXS-JE-LT046 IRWST Level PXS-JE-LT047 IRWST Level PXS-JE-LT048 RCS Hot Leg Water Level RCS-JE-LT160A RCS Hot Leg Water Level RCS-JE-LT160B PZR Level RCS-JE-LT195A PZR Level RCS-JE-LT195B PZR Level RCS-JE-LT195C PZR Level RCS-JE-LT195D SG1 Narrow Range Level SGS-JE-LT001 SG1 Narrow Range Level SGS-JE-LT002 SG1 Narrow Range Level SGS-JE-LT003 SG1 Narrow Range Level SGS-JE-LT004 SG2 Narrow Range Level SGS-JE-LT005 SG2 Narrow Range Level SGS-JE-LT006 SG2 Narrow Range Level SGS-JE-LT007 SG2 Narrow Range Level SGS-JE-LT008 SG1 Wide Range Level SGS-JE-LT011 SG1 Wide Range Level SGS-JE-LT012 SG1 Wide Range Level SGS-JE-LT015 Table 3I.6-2 (Sheet 8 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-19 Revision 0 Turkey Point Units 6 & 7 - IFSAR SG1 Wide Range Level SGS-JE-LT016 SG2 Wide Range Level SGS-JE-LT013 SG2 Wide Range Level SGS-JE-LT014 SG2 Wide Range Level SGS-JE-LT017 SG2 Wide Range Level SGS-JE-LT018 Spent Fuel Pool Level SFS-JE-LT019A Spent Fuel Pool Level SFS-JE-LT019B Spent Fuel Pool Level SFS-JE-LT019C Air Storage Tank Pressure - A VES-JE-PT001A Air Storage Tank Pressure - B VES-JE-PT001B Containment Pressure Normal Range PCS-JE-PT005 Containment Pressure Normal Range PCS-JE-PT006 Containment Pressure Normal Range PCS-JE-PT007 Containment Pressure Normal Range PCS-JE-PT008 Containment Pressure Extended Range PCS-JE-PT012 Containment Pressure Extended Range PCS-JE-PT013 Containment Pressure Extended Range PCS-JE-PT014 RCS Wide Range Pressure RCS-JE-PT140A RCS Wide Range Pressure RCS-JE-PT140B RCS Wide Range Pressure RCS-JE-PT140C RCS Wide Range Pressure RCS-JE-PT140D PZR Pressure RCS-JE-PT191A PZR Pressure RCS-JE-PT191B PZR Pressure RCS-JE-PT191C PZR Pressure RCS-JE-PT191D Table 3I.6-2 (Sheet 9 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-20 Revision 0 Turkey Point Units 6 & 7 - IFSAR Main Steam Line SG1 Pressure SGS-JE-PT030 Main Steam Line SG1 Pressure SGS-JE-PT031 Main Steam Line SG1 Pressure SGS-JE-PT032 Main Steam Line SG1 Pressure SGS-JE-PT033 Main Steam Line SG2 Pressure SGS-JE-PT034 Main Steam Line SG2 Pressure SGS-JE-PT035 Main Steam Line SG2 Pressure SGS-JE-PT036 Main Steam Line SG2 Pressure SGS-JE-PT037 Main Control Room Differential Pressure VES-JE-PDT004A Main Control Room Differential Pressure VES-JE-PDT004B Protection and Safety Monitoring Systems Protection and Safety Monitoring System Cabinets Multiple MCR/RSW Transfer Switch Panel A PMS-JW-004A MCR/RSW Transfer Switch Panel B PMS-JW-004B MCR/RSW Transfer Switch Panel C PMS-JW-004C MCR/RSW Transfer Switch Panel D PMS-JW-004D Source Range Neutron Flux Preamplifier Panel A PMS-JW-005A Source Range Neutron Flux Preamplifier Panel B PMS-JW-005B Source Range Neutron Flux Preamplifier Panel C PMS-JW-005C Source Range Neutron Flux Preamplifier Panel D PMS-JW-005D Intermediate Range Neutron Flux Preamplifier Panel A PMS-JW-006A Intermediate Range Neutron Flux Preamplifier Panel B PMS-JW-006B Intermediate Range Neutron Flux Preamplifier Panel C PMS-JW-006C Table 3I.6-2 (Sheet 10 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-21 Revision 0 Turkey Point Units 6 & 7 - IFSAR Intermediate Range Neutron Flux Preamplifier Panel D PMS-JW-006D Power Range Neutron Flux High Voltage Distribution Box A PMS-JW-007A Power Range Neutron Flux High Voltage Distribution Box B PMS-JW-007B Power Range Neutron Flux High Voltage Distribution Box C PMS-JW-007C Power Range Neutron Flux High Voltage Distribution Box D PMS-JW-007D Main Control Room Operator Workstation A N/A Operator Workstation B N/A Supervisor Workstation N/A Switch Station (Including Switches)

N/A QDPS MCR Display Unit PMS-JY-001B QDPS MCR Display Unit PMS-JY-001C MCR Load Shed Panel 1 VES-EP-01 MCR Load Shed Panel 2 VES-EP-02 Active Valves Containment Isolation - Air Out Solenoid Valve CAS-PL-V014-S Limit Switch CAS-PL-V014-L Containment Isolation - Inlet Limit Switch CCS-PL-V200-L Motor Operator CCS-PL-V200-M Containment Isolation - Outlet Limit Switch CCS-PL-V207-L Motor Operator CCS-PL-V207-M Containment Isolation - Outlet Limit Switch CCS-PL-V208-L Motor Operator CCS-PL-V208-M Table 3I.6-2 (Sheet 11 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-22 Revision 0 Turkey Point Units 6 & 7 - IFSAR RCS Purification Stop Valve Limit Switch CVS-PL-V001-L Motor Operator CVS-PL-V001-M RCS Purification Stop Valve Limit Switch CVS-PL-V002-L Motor Operator CVS-PL-V002-M RCS Letdown Stop Valve Limit Switch CVS-PL-V003-L Motor Operator CVS-PL-V003-M WLS Letdown IRC Isolation Limit Switch CVS-PL-V045-L Solenoid Valve CVS-PL-V045-S1 Letdown Flow ORC Isolation Limit Switch CVS-PL-V047-L Solenoid Valve CVS-PL-V047-S1 Auxiliary PZR Spray Isolation Limit Switch CVS-PL-V084-L Solenoid Valve CVS-PL-V084-S Makeup Line Containment Isolation Limit Switch CVS-PL-V090-L Motor Operator CVS-PL-V090-M Makeup Line Containment Isolation Limit Switch CVS-PL-V091-L Motor Operator CVS-PL-V091-M Table 3I.6-2 (Sheet 12 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-23 Revision 0 Turkey Point Units 6 & 7 - IFSAR Hydrogen Addition Containment Isolation Limit Switch CVS-PL-V092-L Solenoid Valve CVS-PL-V092-S Demineralizer Water System Isolation Limit Switch CVS-PL-V136A-L Solenoid Valve CVS-PL-V136A-S Demineralized Water System Isolation Limit Switch CVS-PL-V136B-L Solenoid Valve CVS-PL-V136B-S PCCWST Isolation Valve Limit Switch PCS-PL-V001A-L Solenoid Valve PCS-PL-V001A-S1 PCCWST Isolation Valve Limit Switch PCS-PL-V001B-L Solenoid Valve PCS-PL-V001B-S1 PCCWST Isolation Valve Limit Switch PCS-PL-V001C-L Motor Operator PCS-PL-V001C-M PCCWST Isolation Valve Limit Switch PCS-PL-V002A-L Motor Operator PCS-PL-V002A-M PCCWST Isolation Valve Limit Switch PCS-PL-V002B-L Motor Operator PCS-PL-V002B-M Table 3I.6-2 (Sheet 13 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-24 Revision 0 Turkey Point Units 6 & 7 - IFSAR PCCWST Isolation Valve Limit Switch PCS-PL-V002C-L Motor Operator PCS-PL-V002C-M Containment Isolation - Air Sample Line Limit Switch PSS-PL-V008-L Solenoid Operator PSS-PL-V008-S Containment Isolation - Liquid Sample Line Limit Switch PSS-PL-V010A-L Solenoid Operator PSS-PL-V010A-S Containment Isolation - Liquid Sample Line Limit Switch PSS-PL-V010B-L Solenoid Operator PSS-PL-V010B-S Containment Isolation - Liquid Sample Line Limit Switch PSS-PL-V011-L Solenoid Valve PSS-PL-V011-S Containment Isolation - Sample Return Line Limit Switch PSS-PL-V023-L Solenoid Valve PSS-PL-V023-S Containment Isolation - Air Sample Line Limit Switch PSS-PL-V046-L Solenoid Valve PSS-PL-V046-S Core Makeup Tank A Discharge Isolation Limit Switch PXS-PL-V014A-L Solenoid Valve PXS-PL-V014A-S1 Table 3I.6-2 (Sheet 14 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-25 Revision 0 Turkey Point Units 6 & 7 - IFSAR Core Makeup Tank B Discharge Isolation Limit Switch PXS-PL-V014B-L Solenoid Valve PXS-PL-V014B-S1 Core Makeup Tank A Discharge Isolation Limit Switch PXS-PL-V015A-L Solenoid Valve PXS-PL-V015A-S1 Core Makeup Tank B Discharge Isolation Limit Switch PXS-PL-V015B-L Solenoid Valve PXS-PL-V015B-S1 Nitrogen Supply Outside Containment Isolation Limit Switch PXS-PL-V042-L Solenoid Valve PXS-PL-V042-S PRHR HX Discharge Isolation Limit Switch PXS-PL-V108A-L Solenoid Valve PXS-PL-V108A-S1 PRHR HX Discharge Isolation Limit Switch PXS-PL-V108B-L Solenoid Valve PXS-PL-V108B-S1 Recirc Sump A Isolation Limit Switch PXS-PL-V118A-L Squib Operator PXS-PL-V118A-T Recirc Sump B Isolation Limit Switch PXS-PL-V118B-L Squib Operator PXS-PL-V118B-T Table 3I.6-2 (Sheet 15 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-26 Revision 0 Turkey Point Units 6 & 7 - IFSAR Recirc Sump A Limit Switch PXS-PL-V120A-L Squib Operator PXS-PL-V120A-T Recirc Sump B Limit Switch PXS-PL-V120B-L Squib Operator PXS-PL-V120B-T IRWST Injection A Limit Switch PXS-PL-V123A-L Squib Operator PXS-PL-V123A-T IRWST Injection B Limit Switch PXS-PL-V123B-L Squib Operator PXS-PL-V123B-T IRWST Injection A Limit Switch PXS-PL-V125A-L Squib Operator PXS-PL-V125A-T IRWST Injection B Limit Switch PXS-PL-V125B-L Squib Operator PXS-PL-V125B-T IRWST Gutter Drain Isolation A Limit Switch PXS-PL-V130A-L Solenoid Valve PXS-PL-V130A-S1 IRWST Gutter Drain Isolation B Limit Switch PXS-PL-V130B-L Solenoid Valve PXS-PL-V130B-S1 Table 3I.6-2 (Sheet 16 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-27 Revision 0 Turkey Point Units 6 & 7 - IFSAR First Stage ADS Limit Switch RCS-PL-V001A-L Motor Operator RCS-PL-V001A-M First Stage ADS Limit Switch RCS-PL-V001B-L Motor Operator RCS-PL-V001B-M Second Stage ADS Limit Switch RCS-PL-V002A-L Motor Operator RCS-PL-V002A-M Second Stage ADS Limit Switch RCS-PL-V002B-L Motor Operator RCS-PL-V002B-M Third Stage ADS Limit Switch RCS-PL-V003A-L Motor Operator RCS-PL-V003A-M Third Stage ADS Limit Switch RCS-PL-V003B-L Motor Operator RCS-PL-V003B-M Fourth Stage ADS Limit Switch RCS-PL-V004A-L Squib Operator RCS-PL-V004A-T Fourth Stage ADS Limit Switch RCS-PL-V004B-L Squib Operator RCS-PL-V004B-T Table 3I.6-2 (Sheet 17 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-28 Revision 0 Turkey Point Units 6 & 7 - IFSAR Fourth Stage ADS Limit Switch RCS-PL-V004C-L Squib Operator RCS-PL-V004C-T Fourth Stage ADS Limit Switch RCS-PL-V004D-L Squib Operator RCS-PL-V004D-T First Stage ADS Isolation Limit Switch RCS-PL-V011A-L Motor Operator RCS-PL-V011A-M First Stage ADS Isolation Limit Switch RCS-PL-V011B-L Motor Operator RCS-PL-V011B-M Second Stage ADS Isolation Limit Switch RCS-PL-V012A-L Motor Operator RCS-PL-V012A-M Second Stage ADS Isolation Limit Switch RCS-PL-V012B-L Motor Operator RCS-PL-V012B-M Third Stage ADS Isolation Limit Switch RCS-PL-V013A-L Motor Operator RCS-PL-V013A-M Third Stage ADS Isolation Limit Switch RCS-PL-V013B-L Motor Operator RCS-PL-V013B-M Table 3I.6-2 (Sheet 18 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-29 Revision 0 Turkey Point Units 6 & 7 - IFSAR Reactor Vessel Head Vent Limit Switch RCS-PL-V150A-L Solenoid Operator RCS-PV-V150A-S Reactor Vessel Head Vent Limit Switch RCS-PL-V150B-L Solenoid Operator RCS-PL-V150B-S Reactor Vessel Head Vent Limit Switch RCS-PL-V150C-L Solenoid Operator RCS-PL-V150C-S Reactor Vessel Head Vent Limit Switch RCS-PL-V150D-L Solenoid Operator RCS-PL-V150D-S RCS Inner Suction Isolation Limit Switch RNS-PL-V001A-L Motor Operator RNS-PL-V001A-M RCS Inner Suction Isolation Limit Switch RNS-PL-V001B-L Motor Operator RNS-PL-V001B-M RCS Outer Suction Isolation Limit Switch RNS-PL-V002A-L Motor Operator RNS-PL-V002A-M RCS Outer Suction Isolation Limit Switch RNS-PL-V002B-L Motor Operator RNS-PL-V002B-M Table 3I.6-2 (Sheet 19 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-30 Revision 0 Turkey Point Units 6 & 7 - IFSAR RHR Control/Isolation Valve Limit Switch RNS-PL-V011-L Motor Operator RNS-PL-V011-M RHR Pump Suction Header Isolation Limit Switch RNS-PL-V022-L Motor Operator RNS-PL-V022-M IRWST Suction Line Isolation Limit Switch RNS-PL-V023-L Motor Operator RNS-PL-V023-M RNS - CVS Containment Isolation Limit Switch RNS-PL-V061-L Air Operator RNS-PL-V061-S SDS - MCR Isolation Limit Switch SDS-PL-V001-L Motor Operator SDS-PL-V001-M SDS - MCR Isolation Limit Switch SDS-PL-V002-L Motor Operator SDS-PL-V002-M Containment Isolation Limit Switch SFS-PL-V034-L Motor Operator SFS-PL-V034-M Containment Isolation Limit Switch SFS-PL-V035-L Motor Operator SFS-PL-V035-M Containment Isolation Limit Switch SFS-PL-V038-L Motor Operator SFS-PL-V038-M Table 3I.6-2 (Sheet 20 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-31 Revision 0 Turkey Point Units 6 & 7 - IFSAR PORV Block Valve Limit Switch SGS-PL-V027A-L Motor Operator SGS-PL-V027A-M PORV Block Valve Limit Switch SGS-PL-V027B-L Motor Operator SGS-PL-V027B-M Steam Line Condensate Drain Isolation Limit Switch SGS-PL-V036A-L Solenoid Valve SGS-PL-V036A-S Steam Line Condensate Isolation Limit Switch SGS-PL-V036B-L Solenoid Valve SGS-PL-V036B-S Main Steam Line Isolation Limit Switch SGS-PL-V040A-L Solenoid Valve SGS-PL-V040A-S1 Solenoid Valve SGS-PL-V040A-S2 Solenoid Valve SGS-PL-V040A-S3 Solenoid Valve SGS-PL-V040A-S4 Main Steam Line Isolation Limit Switch SGS-PL-V040B-L Solenoid Valve SGS-PL-V040B-S1 Solenoid Valve SGS-PL-V040B-S2 Solenoid Valve SGS-PL-V040B-S3 Solenoid Valve SGS-PL-V040B-S4 Table 3I.6-2 (Sheet 21 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-32 Revision 0 Turkey Point Units 6 & 7 - IFSAR Main Feedwater Isolation Limit Switch SGS-PL-V057A-L Solenoid Valve SGS-PL-V057A-S1 Solenoid Valve SGS-PL-V057A-S2 Solenoid Valve SGS-PL-V057A-S3 Solenoid Valve SGS-PL-V057A-S4 Main Feedwater Isolation Limit Switch SGS-PL-V057B-L Solenoid Valve SGS-PL-V057B-S1 Solenoid Valve SGS-PL-V057B-S2 Solenoid Valve SGS-PL-V057B-S3 Solenoid Valve SGS-PL-V057B-S4 Startup Feedwater Isolation Limit Switch SGS-PL-V067A-L Motor Operator SGS-PL-V067A-M Startup Feedwater Isolation Limit Switch SGS-PL-V067B-L Motor Operator SGS-PL-V067B-M SG Blowdown Isolation Limit Switch SGS-PL-V074A-L Solenoid Valve SGS-PL-V074A-S SG Blowdown Isolation Limit Switch SGS-PL-V074B-L Solenoid Valve SGS-PL-V074B-S Table 3I.6-2 (Sheet 22 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-33 Revision 0 Turkey Point Units 6 & 7 - IFSAR SG Series Blowdown Isolation Limit Switch SGS-PL-V075A-L Solenoid Valve SGS-PL-V075A-S SG Series Blowdown Isolation Limit Switch SGS-PL-V075B-L Solenoid Valve SGS-PL-V075B-S Steam Line Condensate Drain Isolation Solenoid Valve SGS-PL-V086A-S Steam Line Condensate Drain Isolation Solenoid Valve SGS-PL-V086B-S Power Operated Relief Valve Limit Switch SGS-PL-V233A-L Solenoid Valve SGS-PL-V233A-S Power Operated Relief Valve Limit Switch SGS-PL-V233B-L Solenoid Valve SGS-PL-V233B-S MSIV Bypass Isolation Valve Limit Switch SGS-PL-V240A-L Solenoid Valve SGS-PL-V240A-S1 Solenoid Valve SGS-PL-V240A-S2 MSIV Bypass Isolation Valve Limit Switch SGS-PL-V240B-L Solenoid Valve SGS-PL-V240B-S1 Solenoid Valve SGS-PL-V240B-S2 Table 3I.6-2 (Sheet 23 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-34 Revision 0 Turkey Point Units 6 & 7 - IFSAR Main Feedwater Control Valve Limit Switch SGS-PL-V250A-L Solenoid Valve SGS-PL-V250A-S Main Feedwater Control Valve Limit Switch SGS-PL-V250B-L Solenoid Valve SGS-PL-V250B-S Startup Feedwater Control Valve Limit Switch SGS-PL-V255A-L Solenoid Valve SGS-PL-V255A-S Startup Feedwater Control Valve Limit Switch SGS-PL-V255B-L Solenoid Valve SGS-PL-V255B-S MCR Isolation Valve Limit Switch VBS-PL-V186-L Motor Operator VBS-PL-V186-M MCR Isolation Valve Limit Switch VBS-PL-V187-L Motor Operator VBS-PL-V187-M MCR Isolation Valve Limit Switch VBS-PL-V188-L Motor Operator VBS-PL-V188-M MCR Isolation Valve Limit Switch VBS-PL-V189-L Motor Operator VBS-PL-V189-M Table 3I.6-2 (Sheet 24 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-35 Revision 0 Turkey Point Units 6 & 7 - IFSAR MCR Isolation Valve Limit Switch VBS-PL-V190-L Motor Operator VBS-PL-V190-M MCR Isolation Valve Limit Switch VBS-PL-V191-L Motor Operator VBS-PL-V191-M Actuation Valve A Limit Switch VES-PL-V005A-L Solenoid Operator VES-PL-V005A-S Actuation Valve B Limit Switch VES-PL-V005B-L Solenoid Operator VES-PL-V005B-S Relief Isolation Valve A Limit Switch VES-PL-V022A-L Solenoid Valve VES-PL-V022A-S Relief Isolation Valve B Limit Switch VES-PL-V022B-L Solenoid Valve VES-PL-V022B-S Containment Purge Inlet Isolation Limit Switch VFS-PL-V003-L Solenoid Valve VFS-PL-V003-S1 Containment Purge Inlet Isolation Limit Switch VFS-PL-V004-L Solenoid Valve VFS-PL-V004-S1 Table 3I.6-2 (Sheet 25 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-36 Revision 0 Turkey Point Units 6 & 7 - IFSAR Containment Purge Discharge Isolation Limit Switch VFS-PL-V009-L Solenoid Valve VFS-PL-V009-S1 Containment Purge Discharge Isolation Limit Switch VFS-PL-V010-L Solenoid Valve VFS-PL-V010-S1 Vacuum Relief Containment Isolation Valve A - ORC Limit Switch VFS-PL-V800A-L Motor Operator VFS-PL-V800A-M Vacuum Relief Containment Isolation Valve B - ORC Limit Switch VFS-PL-V800B-L Motor Operator VFS-PL-V800B-M Fan Cooler Supply Isolation Limit Switch VWS-PL-V058-L Solenoid Valve VWS-PL-V058-S Fan Cooler Return Isolation Limit Switch VWS-PL-V082-L Solenoid Valve VWS-PL-V082-S Fan Cooler Return Isolation Limit Switch VWS-PL-V086-L Solenoid Valve VWS-PL-V086-S Sump Containment Isolation IRC Limit Switch WLS-PL-V055-L Solenoid Valve WLS-PL-V055-S1 Table 3I.6-2 (Sheet 26 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-37 Revision 0 Turkey Point Units 6 & 7 - IFSAR Sump Containment Isolation ORC Limit Switch WLS-PL-V057-L Solenoid Valve WLS-PL-V057-S1 RCDT Gas Containment Isolation Limit Switch WLS-PL-V067-L Solenoid Valve WLS-PL-V067-S RCDT Gas Containment Isolation Limit Switch WLS-PL-V068-L Solenoid Valve WLS-PL-V068-S Hot Leg 1 Sample Isolation Limit Switch PSS-PL-V001A-L Hot Leg 2 Sample Isolation Limit Switch PSS-PL-V001B-L Core Makeup Tank A CL Inlet Isolation Limit Switch PXS-PL-V002A-L Motor Operator PXS-PL-V002A-M Core Makeup Tank B CL Inlet Isolation Limit Switch PXS-PL-V002B-L Motor Operator PXS-PL-V002B-M PRHR HX Inlet Isolation Limit Switch PXS-PL-V101-L Motor Operator PXS-PL-V101-M Recirc Sump A Isolation Limit Switch PXS-PL-V117A-L Motor Operator PXS-PL-V117A-M Table 3I.6-2 (Sheet 27 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-38 Revision 0 Turkey Point Units 6 & 7 - IFSAR Recirc Sump B Isolation Limit Switch PXS-PL-V117B-L Motor Operator PXS-PL-V117B-M Fourth Stage ADS Isolation Limit Switch RCS-PL-V014A-L Motor Operator RCS-PL-V014A-M Fourth Stage ADS Isolation Limit Switch RCS-PL-V014B-L Motor Operator RCS-PL-V014B-M Fourth Stage ADS Isolation Limit Switch RCS-PL-V014C-L Motor Operator RCS-PL-V014C-M Fourth Stage ADS Isolation Limit Switch RCS-PL-V014D-L Motor Operator RCS-PL-V014D-M Table 3I.6-2 (Sheet 28 of 28)

List of Potential High Frequency Sensitive AP1000 Safety-Related electrical and Electro-mechanical Equipment Description AP1000 Tag Number

3I-39 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3I.6-3 (Sheet 1 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment Resistance Temperature Detectors PRHR HX Outlet Temperature RCS-JE-TE161 1

RCS Cold Leg 1A Narrow Range Temperature RCS-JE-TE121A 1

RCS Cold Leg 1A Narrow Range Temperature RCS-JE-TE121D 1

RCS Cold Leg 1B Narrow Range Temperature RCS-JE-TE121B 1

RCS Cold Leg 1B Narrow Range Temperature RCS-JE-TE121C 1

RCS Cold Leg 2A Narrow Range Temperature RCS-JE-TE122B 1

RCS Cold Leg 2A Narrow Range Temperature RCS-JE-TE122C 1

RCS Cold Leg 2B Narrow Range Temperature RCS-JE-TE122A 1

RCS Cold Leg 2B Narrow Range Temperature RCS-JE-TE122D 1

RCS Hot Leg 1 Narrow Range Temperature RCS-JE-TE131A 1

RCS Hot Leg 1 Narrow Range Temperature RCS-JE-TE131C 1

RCS Hot Leg 1 Narrow Range Temperature RCS-JE-TE132A 1

RCS Hot Leg 1 Narrow Range Temperature RCS-JE-TE132C 1

RCS Hot Leg 1 Narrow Range Temperature RCS-JE-TE133C 1

RCS Hot Leg 1 Narrow Range Temperature RCS-JE-TE133A 1

RCS Hot Leg 2 Narrow Range Temperature RCS-JE-TE131B 1

RCS Hot Leg 2 Narrow Range Temperature RCS-JE-TE131D 1

RCS Hot Leg 2 Narrow Range Temperature RCS-JE-TE132B 1

RCS Hot Leg 2 Narrow Range Temperature RCS-JE-TE132D 1

RCS Hot Leg 2 Narrow Range Temperature RCS-JE-TE133B 1

RCS Hot Leg 2 Narrow Range Temperature RCS-JE-TE133D 1

RCS Cold Leg 1A Dual Range Temperature RCS-JE-TE125A 1

RCS Cold Leg 1B Dual Range Temperature RCS-JE-TE125C 1

RCS Cold Leg 2A Dual Range Temperature RCS-JE-TE125B 1

3I-40 Revision 0 Turkey Point Units 6 & 7 - IFSAR RCS Cold Leg 2B Dual Range Temperature RCS-JE-TE125D 1

RCS Hot Leg 1 Wide Range Temperature RCS-JE-TE135A 1

RCS Hot Leg 2 Wide Range Temperature RCS-JE-TE135B 1

PZR Reference Leg Level Temperature RCS-JE-TE193A 1

PZR Reference Leg Level Temperature RCS-JE-TE193B 1

PZR Reference Leg Level Temperature RCS-JE-TE193C 1

PZR Reference Leg Level Temperature RCS-JE-TE193D 1

Thermocouples 1

Incore Thermocouples IIS-JE-TE001-TE042 1

RCP 1A Bearing Water Temperature RCS-JE-TE211A 1

RCP 1A Bearing Water Temperature RCS-JE-TE211B 1

RCP 1A Bearing Water Temperature RCS-JE-TE211C 1

RCP 1A Bearing Water Temperature RCS-JE-TE211D 1

RCP 1B Bearing Water Temperature RCS-JE-TE212A 1

RCP 1B Bearing Water Temperature RCS-JE-TE212B 1

RCP 1B Bearing Water Temperature RCS-JE-TE212C 1

RCP 1B Bearing Water Temperature RCS-JE-TE212D 1

RCP 2A Bearing Water Temperature RCS-JE-TE213A 1

RCP 2A Bearing Water Temperature RCS-JE-TE213B 1

RCP 2A Bearing Water Temperature RCS-JE-TE213C 1

RCP 2A Bearing Water Temperature RCS-JE-TE213D 1

RCP 2B Bearing Water Temperature RCS-JE-TE214A 1

RCP 2B Bearing Water Temperature RCS-JE-TE214B 1

RCP 2B Bearing Water Temperature RCS-JE-TE214C 1

RCP 2B Bearing Water Temperature RCS-JE-TE214D 1

Table 3I.6-3 (Sheet 2 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-41 Revision 0 Turkey Point Units 6 & 7 - IFSAR Penetrations Penetrations (Mechanical) 1 Penetrations (Electrical) 1 Active Valves Containment Isolation - Air Out CAS-PL-V014 2

Containment Isolation - Air In CAS-PL-V015 2

Containment Isolation - Inlet CCS-PL-V200 2

Service Air Supply Inside Containment Isolation CAS-PL-V205 2

Containment Isolation - Inlet CCS-PL-V201 2

Containment Isolation - Outlet CCS-PL-V207 2

Containment Isolation - Outlet CCS-PL-V208 2

CCS Containment Isolation Relief CCS-PL-V220 2

CCS IRC Relief Valve CCS-PL-V270 2

CCS IRC Relief Valve CCS-PL-V271 2

RCS Purification Stop Valve CVS-PL-V001 2

RCS Purification Stop Valve CVS-PL-V002 2

RCS Letdown Stop Valve CVS-PL-V003 2

Demineralizer Flush Line Relief Valve CVS-PL-V042 2

WLS Letdown IRC Isolation CVS-PL-V045 2

Letdown Flow ORC Isolation CVS-PL-V047 2

RCS Purification Check Valve CVS-PL-V080 2

RCS Purification Stop Valve CVS-PL-V081 2

RCS Purification Check Valve CVS-PL-V082 2

Auxiliary PZR Spray Isolation CVS-PL-V084 2

Auxiliary PZR Spray Isolation CVS-PL-V085 2

Makeup Line Containment Isolation CVS-PL-V090 2

Makeup Line Containment Isolation CVS-PL-V091 2

Table 3I.6-3 (Sheet 3 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-42 Revision 0 Turkey Point Units 6 & 7 - IFSAR Hydrogen Addition Containment Isolation CVS-PL-V092 2

Hydrogen Addition Containment Isolation CVS-PL-V094 2

Hydrogen Addition Containment Isolation CVS-PL-V092 2

Hydrogen Addition Containment Isolation CVS-PL-V094 2

Makeup Containment Isolation CVS-PL-V100 2

Demineralizer Water System Isolation CVS-PL-V136A 2

Demineralized Water System Isolation CVS-PL-V136B 2

Demin Water Supply Containment Isolation - Inside DWS-PL-V245 2

Fuel Transfer Tube Gate Valve FHS-PL-V001 2

Fire Water Containment Supply Isolation - Inside FPS-PL-V052 2

PCCWST Isolation Valve PCS-PL-V001A 2

PCCWST Isolation Valve PCS-PL-V001B 2

PCCWST Isolation Valve PCS-PL-V001C 2

PCCWST Isolation Valve PCS-PL-V002A 2

PCCWST Isolation Valve PCS-PL-V002B 2

PCCWST Isolation Valve PCS-PL-V002C 2

PCCWST Fire Protection Isolation PCS-PL-V005 2

PCCWST Emergency Spent Fuel Pool Makeup Isolation PCS-PL-V009 2

Water Bucket Makeup Line Drain Valve PCS-PL-V015 2

Water Bucket Makeup Line Isolation Valve PCS-PL-V020 2

PCS Recirculation Isolation PCS-PL-V023 2

PCCWST Long-Term Makeup Check Valve PCS-PL-V039 2

PCCWST Long Term Makeup Isolation Drain Valve PCS-PL-V042 2

PCCWST Long Term Makeup Isolation Valve PCS-PL-V044 2

Emergency Makeup to the Spent Fuel Pool Isolation Valve PCS-PL-V045 2

Table 3I.6-3 (Sheet 4 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-43 Revision 0 Turkey Point Units 6 & 7 - IFSAR PCCWST Recirculation Return Isolation Valve PCS-PL-V046 2

Emergency Makeup to the Spent Fuel Pool Drain Isolation Valve PCS-PL-V049 2

Spent Fuel Pool Long Term Makeup Isolation Valve PCS-PL-V050 2

Spent Fuel Pool Emergency Makeup Lower Isolation Valve PCS-PL-V051 2

Containment Isolation - Air Sample Line PSS-PL-V008 2

Containment Isolation - Liquid Sample Line PSS-PL-V010A 2

Containment Isolation - Liquid Sample Line PSS-PL-V010B 2

Containment Isolation - Liquid Sample Line PSS-PL-V011 2

Containment Isolation - Sample Return Line PSS-PL-V023 2

Containment Isolation Sample Return PSS-PL-V024 2

Containment Isolation - Air Sample Line PSS-PL-V046 2

PWS MCR Isolation PWS-PL-V418 2

PWS MCR Isolation PWS-PL-V420 2

PWS MCR Vacuum Relief PWS-PL-V498 2

Core Makeup Tank A Discharge Isolation PXS-PL-V014A 2

Core Makeup Tank B Discharge Isolation PXS-PL-V014B 2

Core Makeup Tank A Discharge Isolation PXS-PL-V015A 2

Core Makeup Tank B Discharge Isolation PXS-PL-V015B 2

Core Makeup Tank A Discharge PXS-PL-V016A 2

Core Makeup Tank B Discharge PXS-PL-V016B 2

Core Makeup Tank A Discharge PXS-PL-V017A 2

Core Makeup Tank B Discharge PXS-PL-V017B 2

Accumulator A Pressure Relief PXS-PL-V022A 2

Accumulator B Pressure Relief PXS-PL-V022B 2

Accumulator A Discharge PXS-PL-V028A 2

Table 3I.6-3 (Sheet 5 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-44 Revision 0 Turkey Point Units 6 & 7 - IFSAR Accumulator B Discharge PXS-PL-V028B 2

Accumulator A Discharge PXS-PL-V029A 2

Accumulator B Discharge PXS-PL-V029B 2

Nitrogen Supply Outside Containment Isolation PXS-PL-V042 2

IRC Nitrogen Supply Inside Containment Isolation PXS-PL-V043 2

PRHR HX Discharge Isolation PXS-PL-V108A 2

PRHR HX Discharge Isolation PXS-PL-V108B 2

Recirc Sump A Isolation PXS-PL-V118A 2

Recirc Sump B Isolation PXS-PL-V118B 2

Recirc Sump A Isolation PXS-PL-V119A 2

Recirc Sump B Isolation PXS-PL-V119B 2

Recirc Sump A Isolation PXS-PL-V120A 2

Recirc Sump B Isolation PXS-PL-V120B 2

IRWST Injection A PXS-PL-V122A 2

IRWST Injection B PXS-PL-V122B 2

IRWST Injection A PXS-PL-V123A 2

IRWST Injection B PXS-PL-V123B 2

IRWST Injection A PXS-PL-V124A 2

IRWST Injection B PXS-PL-V124B 2

IRWST Injection A PXS-PL-V125A 2

IRWST Injection B PXS-PL-V125B 2

IRWST Gutter Drain Isolation A PXS-PL-V130A 2

IRWST Gutter Drain Isolation B PXS-PL-V130B 2

First Stage ADS RCS-PL-V001A 2

First Stage ADS RCS-PL-V001B 2

Table 3I.6-3 (Sheet 6 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-45 Revision 0 Turkey Point Units 6 & 7 - IFSAR Second Stage ADS RCS-PL-V002A 2

Second Stage ADS RCS-PL-V002B 2

Third Stage ADS RCS-PL-V003A 2

Third Stage ADS RCS-PL-V003B 2

Fourth Stage ADS RCS-PL-V004A 2

Fourth Stage ADS RCS-PL-V004B 2

Fourth Stage ADS RCS-PL-V004C 2

Fourth Stage ADS RCS-PL-V004D 2

PZR Safety Valve RCS-PL-V005A 2

PZR Safety Valve RCS-PL-V005B 2

ADS Discharge Header A Relief RCS-PL-V010A 2

ADS Discharge Header B Relief RCS-PL-V010B 2

First Stage ADS Isolation RCS-PL-V011A 2

First Stage ADS Isolation RCS-PL-V011B 2

Second Stage ADS Isolation RCS-PL-V012A 2

Second Stage ADS Isolation RCS-PL-V012B 2

Third Stage ADS Isolation RCS-PL-V013A 2

Third Stage ADS Isolation RCS-PL-V013B 2

Reactor Vessel Head Vent RCS-PL-V150A 2

Reactor Vessel Head Vent RCS-PL-V150B 2

Reactor Vessel Head Vent RCS-PL-V150C 2

Reactor Vessel Head Vent RCS-PL-V150D 2

RCS Inner Suction Isolation RNS-PL-V001A 2

RCS Inner Suction Isolation RNS-PL-V001B 2

RCS Outer Suction Isolation RNS-PL-V002A 2

Table 3I.6-3 (Sheet 7 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-46 Revision 0 Turkey Point Units 6 & 7 - IFSAR RCS Outer Suction Isolation RNS-PL-V002B 2

RCS Thermal Relief RNS-PL-V003A 2

RCS Thermal Relief RNS-PL-V003B 2

RHR Control/Isolation Valve RNS-PL-V011 2

RNS Discharge Containment Isolation Valve Test Connection RNS-PL-V012 2

RNS Discharge Containment Isolation RNS-PL-V013 2

RNS Discharge RCP B Isolation RNS-PL-V015A 2

RNS Discharge RCP B Isolation RNS-PL-V015B 2

RNS Discharge RCP B Isolation RNS-PL-V017A 2

RNS Discharge RCP B Isolation RNS-PL-V017B 2

RNS Hot Leg Suction Relief RNS-PL-V021 2

RHR Pump Suction Header Isolation RNS-PL-V022 2

IRWST Suction Line Isolation RNS-PL-V023 2

RNS Pump Discharge Relief RNS-PL-V045 2

RNS - CVS Containment Isolation RNS-PL-V061 2

Containment Isolation SFS-PL-V034 2

Containment Isolation SFS-PL-V035 2

SFS Discharge Containment Isolation SFS-PL-V037 2

Containment Isolation SFS-PL-V038 2

SFS Cask Loading Pit to SFS Pump SFS-PL-V042 2

SFS Pump to Cask Loading Pit SFS-PL-V045 2

Cask Loading Pit to WLS SFS-PL-V049 2

Spent Fuel Pool to Cask Washdown Pit Isolation SFS-PL-V066 2

SFS Containment Isolation Relief SFS-PL-V067 2

Cask Washdown Pit Drain Isolation SFS-PL-V068 2

Table 3I.6-3 (Sheet 8 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-47 Revision 0 Turkey Point Units 6 & 7 - IFSAR Refueling Cavity to SG Compartment SFS-PL-V071 2

Refueling Cavity to SG Compartment SFS-PL-V072 2

PORV Block Valve SGS-PL-V027A 2

PORV Block Valve SGS-PL-V027B 2

Steam Safety Valve SG01 SGS-PL-V030A 2

Steam Safety Valve SG02 SGS-PL-V030B 2

Steam Safety Valve SG01 SGS-PL-V031A 2

Steam Safety Valve SG02 SGS-PL-V031B 2

Steam Safety Valve SG01 SGS-PL-V032A 2

Steam Safety Valve SG02 SGS-PL-V032B 2

Steam Safety Valve SG01 SGS-PL-V033A 2

Steam Safety Valve SG02 SGS-PL-V033B 2

Steam Safety Valve SG01 SGS-PL-V034A 2

Steam Safety Valve SG02 SGS-PL-V034B 2

Steam Safety Valve SG01 SGS-PL-V035A 2

Steam Safety Valve SG02 Steam Line Condensate SGS-PL-V035B 2

Drain Isolation SGS-PL-V036A 2

Steam Line Condensate Isolation SGS-PL-V036B 2

Main Steam Line Isolation SGS-PL-V040A 2

Main Steam Line Isolation SGS-PL-V040B 2

Main Feedwater Isolation SGS-PL-V057A 2

Main Feedwater Isolation SGS-PL-V057B 2

Startup Feedwater Isolation SGS-PL-V067A 2

Startup Feedwater Isolation SGS-PL-V067B 2

SG Blowdown Isolation SGS-PL-V074A 2

Table 3I.6-3 (Sheet 9 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-48 Revision 0 Turkey Point Units 6 & 7 - IFSAR SG Blowdown Isolation SGS-PL-V074B 2

SG Series Blowdown Isolation SGS-PL-V075A 2

SG Series Blowdown Isolation SGS-PL-V075B 2

Steam Line Condensate Drain Isolation SGS-PL-V086A 2

Steam Line Condensate Drain Isolation SGS-PL-V086B 2

Power-Operated Relief Valve SGS-PL-V233A 2

Power-Operated Relief Valve SGS-PL-V233B 2

MSIV Bypass Isolation Valve SGS-PL-V240A 2

MSIV Bypass Isolation Valve SGSPL-V240B 2

Main Feedwater Control Valve SGS-PL-V250A 2

Main Feedwater Control Valve SGS-PL-V250B 2

Startup Feedwater Control Valve SGS-PL-V255A 2

Startup Feedwater Control Valve SGS-PL-V255B 2

MCR Isolation Valve VBS-PL-V186 2

MCR Isolation Valve VBS-PL-V187 2

MCR Isolation Valve VBS-PL-V188 2

MCR Isolation Valve VBS-PL-V189 2

MCR Isolation Valve VBS-PL-V190 2

MCR Isolation Valve VBS-PL-V191 2

Air Delivery Isolation Valve VES-PL-V001 2

Pressure Regulator Valve A VES-PL-V002A 2

Pressure Regulator Valve B VES-PL-V002B 2

Actuation Valve A VES-PL-V005A 2

Actuation Valve B VES-PL-V005B 2

Temporary Instrument Isolation Valve A VES-PL-V018 2

Temporary Instrument Isolation Valve B VES-PL-V019 2

Relief Isolation Valve A VES-PL-V022A 2

Relief Isolation Valve B VES-PL-V022B 2

Table 3I.6-3 (Sheet 10 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-49 Revision 0 Turkey Point Units 6 & 7 - IFSAR Air Tank Relief A VES-PL-V040A 2

Air Tank Relief B VES-PL-V040B 2

Air Tank Relief A VES-PL-V041A 2

Air Tank Relief B VES-PL-V041B 2

Main Air Flow Path Isolation Valve VES-PL-V044 2

Containment Purge Inlet Isolation VFS-PL-V003 2

Containment Purge Inlet Isolation VFS-PL-V004 2

Containment Purge Discharge Isolation VFS-PL-V009 2

Containment Purge Discharge Isolation VFS-PL-V010 2

Vacuum Relief Containment Isolation Valve A - ORC VFS-PL-V800A 2

Vacuum Relief Containment Isolation Valve B - ORC VFS-PL-V800B 2

Vacuum Relief Containment Isolation Check Valve A - IRC VFS-PL-V803A 2

Vacuum Relief Containment Isolation Check Valve B - IRC VFS-PL-V803B 2

Fan Cooler Supply Isolation VWS-PL-V058 2

Fan Cooler Supply Isolation VWS-PL-V062 2

VWS Containment Isolation Relief VWS-PL-V080 2

Fan Cooler Return Isolation VWS-PL-V082 2

Fan Cooler Return Isolation VWS-PL-V086 2

Sump Containment Isolation IRC WLS-PL-V055 2

Sump Containment Isolation ORC WLS-PL-V057 2

WLS Containment Isolation Relief WLS-PL-V058 2

RCDT Gas Containment Isolation WLS-PL-V067 2

RCDT Gas Containment Isolation WLS-PL-V068 2

CVS To Sump WLS-PL-V071 A 2

PXS A To Sump WLS-PL-V071 B 2

Table 3I.6-3 (Sheet 11 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-50 Revision 0 Turkey Point Units 6 & 7 - IFSAR PXS B To Sump WLS-PL-V071 C 2

CVS To Sump WLS-PL-V072 A 2

PXS A To Sump WLS-PL-V072 B 2

PXS B To Sump WLS-PL-V072 C 2

Miscellaneous Nonactive Valves Containment Penetration Test Connection Isolation CAS-PL-V027 2

Service Air Supply Outside Containment Isolation CAS-PL-V204 2

Containment Penetration Test Connection Isolation CAS-PL-V219 2

Containment Isolation Valve Test Connection - Outlet Line CCS-PL-V209 2

CCS Supply Containment Isolation - IRC CCS-PL-V214 2

CCS Supply Containment Isolation Valve Test Connection - IRC CCS-PL-V215 2

Containment Leak Test Outlet Line - IRC CCS-PL-V216 2

Containment Isolation Valve V207 Body Test Connection Valve CCS-PL-V217 2

Containment Isolation Valve Test Connection - Inlet Line CCS-PL-V257 2

Resin Flush IRC Isolation CVS-PL-V040 2

Resin Flush ORC Isolation CVS-PL-V041 2

Letdown PZR Instrument Root CVS-PL-V046 2

H2 Mkup Containment Isolation Thermal Relief Valve CVS-PL-V065 2

Hydrogen Add Cont Isolation Test Connection CVS-PL-V095 2

Hydrogen Addition Containment Isolation Test Connection CVS-PL-V096 2

Demin Water Supply Containment Isolation - Outside DWS-PL-V244 2

Containment Penetration Test Connection Isolation DWS-PL-V248 2

Fire Water Containment Test Connection Isolation FPS-PL-V049 2

Fire Water Containment Supply Isolation FPS-PL-V050 2

Table 3I.6-3 (Sheet 12 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-51 Revision 0 Turkey Point Units 6 & 7 - IFSAR Fire Water Containment Test Connection Isolation FPS-PL-V051 2

Flow Transmitter FT001 Root Valve PCS-PL-V010A 2

Flow Transmitter FT001 Root Valve PCS-PL-V010B 2

Flow Transmitter FT002 Root Valve PCS-PL-V011A 2

Flow Transmitter FT001 Root Valve PCS-PL-V011B 2

Flow Transmitter FT003 Root Valve PCS-PL-V012A 2

Flow Transmitter FT003 Root Valve PCS-PL-V012B 2

Flow Transmitter FT004 Root Valve PCS-PL-V013A 2

Flow Transmitter FT004 Root Valve PCS-PL-V013B 2

PCCWST Drain Isolation Valve PCS-PL-V016 2

PCCWST Isolation Valve Leakage Detection Drain PCS-PL-V029 2

PCCWST Isolation Valve Leakage Detection Crossconn PCS-PL-V030 2

PCCWST Level Instrument Root Valve PCS-PL-V031A 2

PCCWST Level Instrument Root Valve PCS-PL-V031B 2

Recirculation Pump Suction from Long Term Makeup Isolation Valve PCS-PL-V033 2

Spent Fuel Pool Emergency Makeup Isolation PLS-PL-V052 2

Hot Leg 1 Sample Isolation PSS-PL-V001A 2

Hot Leg 2 Sample Isolation PSS-PL-V001B 2

Pressurizer Sample Isolation PSS-PL-V003 2

PXS Accumulator Sample Isolation PSS-PL-V004A 2

PXS Accumulator Sample Isolation PSS-PL-V004B 2

PXS CMT A Sample Isolation PSS-PL-V005A 2

PXS CMT B Sample Isolation PSS-PL-V005B 2

PXS CMT A Sample Isolation PSS-PL-V005C 2

Table 3I.6-3 (Sheet 13 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-52 Revision 0 Turkey Point Units 6 & 7 - IFSAR PXS CMT B Sample Isolation PSS-PL-V005D 2

Liquid Sample Check Valve PSS-PL-V012A 2

Liquid Sample Check Valve PSS-PL-V012B 2

Containment Testing Boundary Isolation Valve PSS-PL-V076A 2

Containment Testing Boundary Isolation Valve PSS-PL-V076B 2

Containment Isolation Test Connection Isolation Valve PSS-PL-V082 2

Containment Isolation Test Connection Isolation Valve PSS-PL-V083 2

Containment Isolation Test Connection Isolation Valve PSS-PL-V085 2

Containment Isolation Test Connection Isolation Valve PSS-PL-V086 2

Core Makeup Tank A CL Inlet Isolation PXS-PL-V002A 2

Core Makeup Tank B CL Inlet Isolation PXS-PL-V002B 2

Core Makeup Tank A Upper Sample PXS-PL-V010A 2

Core Makeup Tank B Upper Sample PXS-PL-V010B 2

Core Makeup Tank A Lower Sample PXS-PL-V011A 2

Core Makeup Tank B Lower Sample PXS-PL-V011B 2

Core Makeup Tank A Drain PXS-PL-V012A 2

Core Makeup Tank B Drain PXS-PL-V012B 2

Core Makeup Tank Discharge Manual Isolation PXS-PL-V013A 2

Core Makeup Tank B Discharge Manual Isolation PXS-PL-V013B 2

RNS to CMT Injection Line A Drain PXS-PL-V019A 2

RNS to CMT Injection Line B Drain PXS-PL-V019B 2

IRWST Injection Line A Drain PXS-PL-V020A 2

IRWST Injection Line B Drain PXS-PL-V020B 2

Accumulator A N2 Vent PXS-PL-V021A 2

Accumulator B N2 Vent PXS-PL-V021B 2

Table 3I.6-3 (Sheet 14 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-53 Revision 0 Turkey Point Units 6 & 7 - IFSAR Accumulator A PZR Transmitter Isolation PXS-PL-V023A 2

Accumulator B PZR Transmitter Isolation PXS-PL-V023B 2

Accumulator A PZR Transmitter Isolation PXS-PL-V024A 2

Accumulator B PZR Transmitter Isolation PXS-PL-V024B 2

Accumulator A Sample PXS-PL-V025A 2

Accumulator B Sample PXS-PL-V025B 2

Accumulator A Drain PXS-PL-V026A 2

Accumulator B Drain PXS-PL-V026B 2

Accumulator A Discharge Isolation PXS-PL-V027A 2

Accumulator B Discharge Isolation PXS-PL-V027B 2

Core Makeup Tank A Highpoint Vent PXS-PL-V030A 2

Core Makeup Tank B Highpoint Vent PXS-PL-V030B 2

Core Makeup Tank A Highpoint Vent PXS-PL-V031A 2

Core Makeup Tank B Highpoint Vent PXS-PL-V031B 2

Accumulator A Check Valve Drain PXS-PL-V033A 2

Accumulator B Check Valve Drain PXS-PL-V033B 2

Accumulator N2 Containment Penetration Test Connection PXS-PL-V052 2

CMT A Wide Level Upper Root PXS-PL-V080A 2

CMT B Wide Level Upper Root PXS-PL-V080B 2

CMT A Wide Level Lower Root PXS-PL-V081A 2

CMT B Wide Level Lower Root PXS-PL-V081B 2

CMT A Upper Level A Isolation 1 PXS-PL-V082A 2

CMT B Upper Level A Isolation 1 PXS-PL-V082B 2

CMT A Upper Level A Isolation 2 PXS-PL-V083A 2

CMT B Upper Level A Isolation 2 PXS-PL-V083B 2

CMT A Upper Level A Vent PXS-PL-V084A 2

Table 3I.6-3 (Sheet 15 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-54 Revision 0 Turkey Point Units 6 & 7 - IFSAR CMT B Upper Level A Vent PXS-PL-V084B 2

CMT A Upper Level A Drain PXS-PL-V085A 2

CMT B Upper Level A Drain PXS-PL-V085B 2

CMT A Upper Level B Isolation 1 PXS-PL-V086A 2

CMT B Upper Level B Isolation 1 PXS-PL-V086B 2

CMT A Upper Level B Isolation 2 PXS-PL-V087A 2

CMT B Upper Level B Isolation 2 PXS-PL-V087B 2

CMT A Upper Level B Vent PXS-PL-V088A 2

CMT B Upper Level B Vent PXS-PL-V088B 2

CMT A Upper Level B Drain PXS-PL-V089A 2

CMT B Upper Level B Drain PXS-PL-V089B 2

CMT A Lower Level A Isolation 1 PXS-PL-V092A 2

CMT B Lower Level A Isolation 1 PXS-PL-V092B 2

CMT A Lower Level A Isolation 2 PXS-PL-V093A 2

CMT B Lower Level A Isolation 2 PXS-PL-V093B 2

CMT A Lower Level A Vent PXS-PL-V094A 2

CMT B Lower Level A Vent PXS-PL-V094B 2

CMT A Lower Level A Drain PXS-PL-V095A 2

CMT B Lower Level A Drain PXS-PL-V095B 2

CMT A Lower Level B Isolation 1 PXS-PL-V096A 2

CMT B Lower Level B Isolation 1 PXS-PL-V096B 2

CMT A Lower Level B Isolation 2 PXS-PL-V097A 2

CMT B Lower Level B Isolation 2 PXS-PL-V097B 2

CMT A Lower Level B Vent PXS-PL-V098A 2

CMT B Lower Level B Vent PXS-PL-V098B 2

Table 3I.6-3 (Sheet 16 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-55 Revision 0 Turkey Point Units 6 & 7 - IFSAR CMT A Lower Level B Drain PXS-PL-V099A 2

CMT B Lower Level B Drain PXS-PL-V099B 2

PRHR HX Inlet Isolation PXS-PL-V101 2

PRHR HX Inlet Head Vent PXS-PL-V102A 2

PRHR HX Inlet Head Drain PXS-PL-V102B 2

PRHR HX Outlet Head Vent PXS-PL-V103A 2

PRHR HX Outlet Head Drain PXS-PL-V103B 2

PRHR HX Flow Transmitter A Isolation PXS-PL-V104A 2

PRHR HX Flow Transmitter B Isolation PXS-PL-V104B 2

PRHR HX Flow Transmitter A Isolation PXS-PL-V105A 2

PRHR HX Flow Transmitter B Isolation PXS-PL-V105B 2

Containment Recirculation A Highpoint Vent PXS-PL-V106 2

Containment Recirculation A Highpoint Vent PXS-PL-V107 2

PRHR HX/RCS Return Isolation PXS-PL-V109 2

PRHR HX Highpoint Vent PXS-PL-V111A 2

PRHR HX Highpoint Vent PXS-PL-V111B 2

PRHR HX PZR Transmitter Isolation PXS-PL-V113 2

Containment Recirculation A Drain PXS-PL-V115A 2

Containment Recirculation B Drain PXS-PL-V115B 2

Containment Recirculation A Drain PXS-PL-V116A 2

Containment Recirculation B Drain PXS-PL-V116B 2

Recirc Sump A Isolation PXS-PL-V117A 2

Recirc Sump B Isolation PXS-PL-V117B 2

IRWST Line A Isolation PXS-PL-V121A 2

IRWST Line B Isolation PXS-PL-V121B 2

IRWST Injection Check Test PXS-PL-V126A 2

Table 3I.6-3 (Sheet 17 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-56 Revision 0 Turkey Point Units 6 & 7 - IFSAR IRWST Injection Check Test PXS-PL-V126B 2

IRWST Injection Line A Drain PXS-PL-V127 2

IRWST Injection Check Test PXS-PL-V128A 2

IRWST Injection Check Test PXS-PL-V128B 2

IRWST Injection Check Test PXS-PL-V129A 2

IRWST Injection Check Test PXS-PL-V129B 2

IRWST Injection Line A Drain PXS-PL-V131A 2

IRWST Injection Line B Drain PXS-PL-V131B 2

IRWST Injection Line A Drain PXS-PL-V132A 2

IRWST Injection Line B Drain PXS-PL-V132B 2

IRWST Injection Line A Highpoint Vent PXS-PL-V133A 2

IRWST Injection Line B Highpoint Vent PXS-PL-V133B 2

IRWST Injection Line A Highpoint Vent PXS-PL-V134A 2

IRWST Injection Line B Highpoint Vent PXS-PL-V134B 2

IRWST Injection Line A Highpoint Vent Isolation PXS-PL-V135A 2

IRWST Injection Line B Highpoint Vent Isolation PXS-PL-V135B 2

RNS Suction Pump Line Drain PXS-PL-V149 2

IRWST Level Transmitter A Isolation PXS-PL-V150A 2

IRWST Level Transmitter B Isolation PXS-PL-V150B 2

IRWST Level Transmitter C Isolation PXS-PL-V150C 2

IRWST Level Transmitter D Isolation PXS-PL-V150D 2

IRWST Level Transmitter A Isolation PXS-PL-V151A 2

IRWST Level Transmitter B Isolation PXS-PL-V151B 2

IRWST Level Transmitter C Isolation PXS-PL-V151C 2

IRWST Level Transmitter D Isolation PXS-PL-V151D 2

Accumulator A Leak Test PXS-PL-V201A 2

Table 3I.6-3 (Sheet 18 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-57 Revision 0 Turkey Point Units 6 & 7 - IFSAR Accumulator B Leak Test PXS-PL-V201B 2

Accumulator A Leak Test PXS-PL-V202A 2

Accumulator B Leak Test PXS-PL-V202B 2

RNS Discharge Leak Test PXS-PL-V205A 2

RNS Discharge Leak Test PXS-PL-V205B 2

RNS Discharge Leak Test PXS-PL-V206 2

RNS Suction Leak Test PXS-PL-V207A 2

RNS Suction Leak Test PXS-PL-V207B 2

RNS Suction Leak Test PXS-PL-V208A 2

Core Makeup Tank A Fill Isolation PXS-PL-V230A 2

Core Makeup Tank B Fill Isolation PXS-PL-V230B 2

Core Makeup Tank A Fill Check PXS-PL-V231A 2

Core Makeup Tank B Fill Check PXS-PL-V231B 2

Accumulator A Fill/Drain Isolation PXS-PL-V232A 2

Accumulator B Fill/Drain Isolation PXS-PL-V232B 2

CMT A Check Valve Test Valve PXS-PL-V250A 2

CMT B Check Valve Test Valve PXS-PL-V250B 2

CMT A Check Valve Test Valve PXS-PL-V251A 2

CMT B Check Valve Test Valve PXS-PL-V251B 2

CMT A Check Valve Test Valve PXS-PL-V252A 2

CMT B Check Valve Test Valve PXS-PL-V252B 2

ADS Test Valve RCS-PL-V007A 2

ADS Test Valve RCS-PL-V007B 2

Fourth Stage ADS Isolation RCS-PL-V014A 2

Fourth Stage ADS Isolation RCS-PL-V014B 2

Fourth Stage ADS Isolation RCS-PL-V014C 2

Table 3I.6-3 (Sheet 19 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-58 Revision 0 Turkey Point Units 6 & 7 - IFSAR Fourth Stage ADS Isolation RCS-PL-V014D 2

Hot Leg 2 Level Instrument Root RCS-PL-V095 2

Hot Leg 2 Level Instrument Root RCS-PL-V096 2

Hot Leg 1 Level Instrument Root RCS-PL-V097 2

Hot Leg 1 Level Instrument Root RCS-PL-V098 2

Hot Leg 1 Flow Instrument Root RCS-PL-V101A 2

Hot Leg 1 Flow Instrument Root RCS-PL-V101B 2

Hot Leg 1 Flow Instrument Root RCS-PL-V101C 2

Hot Leg 1 Flow Instrument Root RCS-PL-V101D 2

Hot Leg 1 Flow Instrument Root RCS-PL-V101E 2

Hot Leg 1 Flow Instrument Root RCS-PL-V101F 2

Hot Leg 2 Flow Instrument Root RCS-PL-V102A 2

Hot Leg 2 Flow Instrument Root RCS-PL-V102B 2

Hot Leg 2 Flow Instrument Root RCS-PL-V102C 2

Hot Leg 2 Flow Instrument Root RCS-PL-V102D 2

Hot Leg 2 Flow Instrument Root RCS-PL-V102E 2

Hot Leg 2 Flow Instrument Root RCS-PL-V102F 2

PRHR HX Outlet Line Drain RCS-PL-V103 2

Hot Leg 1 Sample Isolation RCS-PL-V108A 2

Hot Leg 2 Sample Isolation RCS-PL-V108B 2

PZR Spray Valve RCS-PL-V110A 2

PZR Spray Valve RCS-PL-V110B 2

PZR Spray Block Valve RCS-PL-V111A 2

PZR Spray Block Valve RCS-PL-V111B 2

Cold Leg 1A Bend Instrument Root RCS-PL-V171A 2

Table 3I.6-3 (Sheet 20 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-59 Revision 0 Turkey Point Units 6 & 7 - IFSAR Cold Leg 1A Bend Instrument Root RCS-PL-V171B 2

Cold Leg 1B Bend Instrument Root RCS-PL-V172A 2

Cold Leg 1B Bend Instrument Root RCS-PL-V172B 2

Cold Leg 2A Bend Instrument Root RCS-PL-V173A 2

Cold Leg 2A Bend Instrument Root RCS-PL-V173B 2

Cold Leg 2B Bend Instrument Root RCS-PL-V174A 2

Cold Leg 2B Bend Instrument Root RCS-PL-V174B 2

PZR Manual Vent RCS-PL-V204 2

PZR Manual Vent RCS-PL-V205 2

PZR Spray Bypass RCS-PL-V210A 2

PZR Spray Bypass RCS-PL-V210B 2

PZR Level Steam Space Instrument Root RCS-PL-V225A 2

PZR Level Steam Space Instrument Root RCS-PL-V225B 2

PZR Level Steam Space Instrument Root RCS-PL-V225C 2

PZR Level Steam Space Instrument Root RCS-PL-V225D 2

PZR Level Liquid Space Instrument Root RCS-PL-V226A 2

PZR Level Liquid Space Instrument Root RCS-PL-V226B 2

PZR Level Liquid Space Instrument Root RCS-PL-V226C 2

PZR Level Liquid Space Instrument Root RCS-PL-V226D 2

Wide Range PZR Level Steam Space Instrument Root RCS-PL-V228 2

Wide Range PZR Level Liquid Space Instrument Root RCS-PL-V229 2

Manual Head Vent RCS-PL-V232 2

Head Vent Isolation RCS-PL-V233 2

ADS Valve Discharge Header Drain Isolation RCS-PL-V241 2

RCP 1A Flush RCS-PL-V260A 2

Table 3I.6-3 (Sheet 21 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-60 Revision 0 Turkey Point Units 6 & 7 - IFSAR RCP 1B Flush RCS-PL-V260B 2

RCP 2A Flush RCS-PL-V260C 2

RCP 2B Flush RCS-PL-V260D 2

RCP 1A Drain RCS-PL-V261A 2

RCP 1B Drain RCS-PL-V261B 2

RCP 2A Drain RCS-PL-V261C 2

RCP 2B Drain RCS-PL-V261D 2

RCS Pressure Boundary Valve Thermal Relief Isolation RNS-PL-V004A 2

RCS Pressure Boundary Valve Thermal Relief Isolation RNS-PL-V004B 2

RNS Pump A Suction Isolation RNS-PL-V005A 2

RNS Pump B Suction Isolation RNS-PL-V005B 2

RNS HX A Outlet Flow Control RNS-PL-V006A 2

RNS HX B Outlet Flow Control RNS-PL-V006B 2

RNS Pump A Discharge Isolation RNS-PL-V007A 2

RNS Pump B Discharge Isolation RNS-PL-V007B 2

RNS HX A Bypass Flow Control RNS-PL-V008A 2

RNS HX B Bypass Flow Control RNS-PL-V008B 2

RNS Discharge Containment Isolation Valve Test RNS-PL-V010 2

RNS Discharge Containment Isolation Valve Test Connection RNS-PL-V014 2

RNS Discharge Containment Penetration Isolation Valves Test RNS-PL-V016 2

RNS Discharge to IRWST Isolation RNS-PL-V024 2

RNS Discharge to CVS RNS-PL-V029 2

RNS Train A Discharge Flow Instrument Isolation RNS-PL-V031A 2

RNS Train B Discharge Flow Instrument Isolation RNS-PL-V031B 2

Table 3I.6-3 (Sheet 22 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-61 Revision 0 Turkey Point Units 6 & 7 - IFSAR RNS Train A Discharge Flow Instrument Isolation RNS-PL-V032A 2

RNS Train B Discharge Flow Instrument Isolation RNS-PL-V032B 2

RNS Pump A Suction Pressure Instrument Isolation RNS-PL-V033A 2

RNS Pump B Suction Pressure Instrument Isolation RNS-PL-V033B 2

RNS Pump A Discharge Pressure Instrument Isolation RNS-PL-V034A 2

RNS Pump B Discharge Pressure Instrument Isolation RNS-PL-V034B 2

RNS Pump A Suction Piping Drain Isolation RNS-PL-V036A 2

RNS Pump B Suction Piping Drain Isolation RNS-PL-V036B 2

RNS HX A Channel Head Drain Isolation RNS-PL-V046A 2

RNS HX B Channel Head Drain Isolation RNS-PL-V046B 2

RNS Pump A Casing Drain Isolation RNS-PL-V050 2

RNS Pump B Casing Drain Isolation RNS-PL-V051 2

RNS Suction from SFP Isolation RNS-PL-V052 2

RNS Discharge to SFP Isolation RNS-PL-V053 2

RNS Suction from Cask Loading Pit Isolation Valve RNS-PL-V055 2

RNS Pump Suction to Cask Loading Pit Isolation RNS-PL-V056 2

RNS Train A Miniflow Isolation Valve RNS-PL-V057A 2

RNS Train B Miniflow Isolation Valve RNS-PL-V057B 2

RNS Pump Suction Containment Isolation Test Connection RNS-PL-V059 2

RNS Discharge to DVI Line A Drain RNS-PL-V066A 2

RNS Discharge to DVI Line B Drain RNS-PL-V066B 2

RNS Discharge to DVI Line A Drain RNS-PL-V067A 2

RNS Discharge to DVI Line B Drain RNS-PL-V067B 2

RNS Discharge to IRWST Drain RNS-PL-V068 2

LT019A Root Isolation Valve SFS-PL-V024A 2

LT019B Root Isolation Valve SFS-PL-V024B 2

Table 3I.6-3 (Sheet 23 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-62 Revision 0 Turkey Point Units 6 & 7 - IFSAR LT019C Root Isolation Valve SFS-PL-V024C 2

LT020 Root Isolation Valve SFS-PL-V028 2

SFS Refueling Cavity Drain To SGS Compartment Isolation SFS-PL-V031 2

SFS Refueling Cavity Suction Isolation SFS-PL-V032 2

SFS Refueling Cavity Drain to Containment Sump Isolation SFS-PL-V033 2

SFS Suction Line from IRWST Isolation SFS-PL-V039 2

SFS Fuel Transfer Canal Suction Isolation SFS-PL-V040 2

SFS Cask Loading Pit Suction Isolation SFS-PL-V041 2

SFS CVS Makeup Reverse Flow Prevention SFS-PL-V043 2

SFS Containment Penetration Test Connection SFS-PL-V048 2

SFS Containment Penetration Test Connection Isolation SFS-PL-V056 2

SFS Containment Isolation Valve V034 Test SFS-PL-V058 2

SFS Containment Floodup Isolation Valve SFS-PL-V075 2

LT001 Root Isolation Valve SGS-PL-V001A 2

LT005 Root Isolation Valve SGS-PL-V001B 2

LT001 Root Isolation Valve SGS-PL-V002A 2

LT005 Root Isolation Valve SGS-PL-V002B 2

LT002 Root Isolation Valve SGS-PL-V003A 2

LT006 Root Isolation Valve SGS-PL-V003B 2

LT002 Root Isolation Valve SGS-PL-V004A 2

LT006 Root Isolation Valve SGS-PL-V004B 2

LT003 Root Isolation Valve SGS-PL-V005A 2

LT007 Root Isolation Valve SGS-PL-V005B 2

LT003 Root Isolation Valve SGS-PL-V006A 2

LT007 Root Isolation Valve SGS-PL-V006B 2

LT004 Root Isolation Valve SGS-PL-V007A 2

Table 3I.6-3 (Sheet 24 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-63 Revision 0 Turkey Point Units 6 & 7 - IFSAR LT008 Root Isolation Valve SGS-PL-V007B 2

LT004 Root Isolation Valve SGS-PL-V008A 2

LT008 Root Isolation Valve SGS-PL-V008B 2

LT011 Root Isolation Valve SGS-PL-V010A 2

LT013 Root Isolation Valve SGS-PL-V010B 2

LT011 Root Isolation Valve SGS-PL-V011A 2

LT013 Root Isolation Valve SGS-PL-V011B 2

LT012 Root Isolation Valve SGS-PL-V012A 2

LT014 Root Isolation Valve SGS-PL-V012B 2

LT012 Root Isolation Valve SGS-PL-V013A 2

LT014 Root Isolation Valve SGS-PL-V013B 2

FT021 Root Isolation Valve SGS-PL-V015A 2

FT023 Root Isolation Valve SGS-PL-V015B 2

FT020 Root Isolation Valve SGS-PL-V016A 2

FT022 Root Isolation Valve SGS-PL-V016B 2

FT021 Root Isolation Valve SGS-PL-V017A 2

FT023 Root Isolation Valve SGS-PL-V017B 2

FT020 Root Isolation Valve SGS-PL-V018A 2

FT022 Root Isolation Valve SGS-PL-V018B 2

Main Steam Line Vent Isolation SGS-PL-V019A 2

Main Steam Line Vent Isolation SGS-PL-V019B 2

PT030 Root Isolation Valve SGS-PL-V022A 2

PT034 Root Isolation Valve SGS-PL-V022B 2

PT031 Root Isolation Valve SGS-PL-V023A 2

PT035 Root Isolation Valve SGS-PL-V023B 2

PT032 Root Isolation Valve SGS-PL-V024A 2

Table 3I.6-3 (Sheet 25 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-64 Revision 0 Turkey Point Units 6 & 7 - IFSAR PT036 Root Isolation Valve SGS-PL-V024B 2

PT033 Root Isolation Valve SGS-PL-V025A 2

PT037 Root Isolation Valve SGS-PL-V025B 2

Steam Line 1 Nitrogen Supply Isolation SGS-PL-V038A 2

Steam Line 2 Nitrogen Supply Isolation SGS-PL-V038B 2

MSIV Bypass Control Isolation SGS-PL-V042A 2

MSIV Bypass Control Isolation SGS-PL-V042B 2

MSIV Bypass Control Isolation SGS-PL-V043A 2

MSIV Bypass Control Isolation SGS-PL-V043B 2

SG1 Condensate Pipe Drain Valve SGS-PL-V045A 2

SG2 Condensate Pipe Drain Valve SGS-PL-V045B 2

LT015 Root Isolation Valve SGS-PL-V046A 2

LT017 Root Isolation Valve SGS-PL-V046B 2

LT015 Root Isolation Valve SGS-PL-V047A 2

LT017 Root Isolation Valve SGS-PL-V047B 2

LT016 Root Isolation Valve SGS-PL-V048A 2

LT018 Root Isolation Valve SGS-PL-V048B 2

LT016 Root Isolation Valve SGS-PL-V049A 2

LT018 Root Isolation Valve SGS-PL-V049B 2

LT044 Root Isolation Valve SGS-PL-V050A 2

LT046 Root Isolation Valve SGS-PL-V050B 2

LT044 Root Isolation Valve SGS-PL-V051A 2

LT046 Root Isolation Valve SGS-PL-V051B 2

LT045 Root Isolation Valve SGS-PL-V052A 2

LT047 Root Isolation Valve SGS-PL-V052B 2

LT045 Root Isolation Valve SGS-PL-V053A 2

Table 3I.6-3 (Sheet 26 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-65 Revision 0 Turkey Point Units 6 & 7 - IFSAR LT047 Root Isolation Valve SGS-PL-V053B 2

PT062 Root Isolation Valve SGS-PL-V056A 2

PT063 Root Isolation Valve SGS-PL-V056B 2

Main Feedwater Check SGS-PL-V058A 2

Main Feedwater Check SGS-PL-V058B 2

FT055A Root Isolation Valve SGS-PL-V062A 2

FT056A Root Isolation Valve SGS-PL-V062B 2

FT055A Root Isolation Valve SGS-PL-V063A 2

FT056A Root Isolation Valve SGS-PL-V063B 2

FT055A Root Isolation Valve SGS-PL-V064A 2

FT056A Root Isolation Valve SGS-PL-V064B 2

FT055A Root Isolation Valve SGS-PL-V065A 2

FT056A Root Isolation Valve SGS-PL-V065B 2

SG1 Nitrogen Sparging Isolation SGS-PL-V084A 2

SG2 Nitrogen Sparging Isolation SGS-PL-V084B 2

Orifice Isolation Valve SGS-PL-V093A 2

Orifice Isolation Valve SGS-PL-V093B 2

Orifice Cleanout Line Isolation Valve SGS-PL-V094A 2

Orifice Cleanout Line Isolation Valve SGS-PL-V094B 2

Orifice Isolation Valve SGS-PL-V095A 2

Orifice Isolation Valve SGS-PL-V095B 2

Steam Line Condensate Drain Level Isolation Valve SGS-PL-V096A 2

Steam Line Condensate Drain Level Isolation Valve SGS-PL-V096B 2

Steam Line Condensate Drain Level Isolation Valve SGS-PL-V097A 2

Steam Line Condensate Drain Level Isolation Valve SGS-PL-V097B 2

Startup Feedwater Check Valve SGS-PL-V256A 2

Table 3I.6-3 (Sheet 27 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-66 Revision 0 Turkey Point Units 6 & 7 - IFSAR Startup Feedwater Check Valve SGS-PL-V256B 2

Air Delivery Line Pressure Instrument Isolation Valve A VES-PL-V006A 2

Air Delivery Line Pressure Instrument Isolation Valve B VES-PL-V006B 2

Temporary Instrument Isolation Valve A VES-PL-V016 2

Deleted Deleted Temporary Instrument Isolation Valve B VES-PL-V020 2

Air Tank Isolation Valve A VES-PL-V024A 2

Air Tank Isolation Valve B VES-PL-V024B 2

Air Tank Isolation Valve A VES-PL-V025A 2

Air Tank Isolation Valve B VES-PL-V025B 2

Refill Line Isolation Valve VES-PL-V038 2

DP Instrument Line Isolation Valve A VES-PL-V043A 2

DP Instrument Line Isolation Valve B VES-PL-V043B 2

Containment Isolation Test Connection VFS-PL-V008 2

Containment Isolation Test Connection VFS-PL-V012 2

Containment Isolation Test Connection VFS-PL-V015 2

Main Equipment Hatch Test Connection VUS-PL-V015 2

Maintenance Equipment Hatch Test Connection VUS-PL-V016 2

Personnel Hatch Test Connection VUS-PL-V017 2

Personnel Hatch Test Connection VUS-PL-V018 2

Personnel Hatch Test Connection VUS-PL-V019 2

Personnel Hatch Test Connection VUS-PL-V020 2

Personnel Hatch Test Connection VUS-PL-V021 2

Personnel Hatch Test Connection VUS-PL-V022 2

Fuel Transfer Tube Test Connection VUS-PL-V023 2

Table 3I.6-3 (Sheet 28 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-67 Revision 0 Turkey Point Units 6 & 7 - IFSAR Electrical Penetration Test Isolation Valve VUS-PL-V101 2

Electrical Penetration Test Isolation Valve VUS-PL-V102 2

Electrical Penetration Test Isolation Valve VUS-PL-V103 2

Electrical Penetration Test Isolation Valve VUS-PL-V104 2

Electrical Penetration Test Isolation Valve VUS-PL-V105 2

Electrical Penetration Test Isolation Valve VUS-PL-V106 2

Electrical Penetration Test Isolation Valve VUS-PL-V107 2

Electrical Penetration Test Isolation Valve VUS-PL-V108 2

Electrical Penetration Test Isolation Valve VUS-PL-V109 2

Electrical Penetration Test Isolation Valve VUS-PL-V110 2

Electrical Penetration Test Isolation Valve VUS-PL-V111 2

Electrical Penetration Test Isolation Valve VUS-PL-V112 2

Electrical Penetration Test Isolation Valve VUS-PL-V113 2

Electrical Penetration Test Isolation Valve VUS-PL-V114 2

Electrical Penetration Test Isolation Valve VUS-PL-V115 2

Electrical Penetration Test Isolation Valve VUS-PL-V116 2

Electrical Penetration Test Isolation Valve VUS-PL-V117 2

Electrical Penetration Test Isolation Valve VUS-PL-V118 2

Electrical Penetration Test Isolation Valve VUS-PL-V119 2

Electrical Penetration Test Isolation Valve VUS-PL-V120 2

Electrical Penetration Test Isolation Valve VUS-PL-V121 2

Electrical Penetration Test Isolation Valve VUS-PL-V122 2

Electrical Penetration Test Isolation Valve VUS-PL-V123 2

Electrical Penetration Test Isolation Valve VUS-PL-V124 2

Electrical Penetration Test Isolation Valve VUS-PL-V125 2

Table 3I.6-3 (Sheet 29 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-68 Revision 0 Turkey Point Units 6 & 7 - IFSAR Spare Penetration Test Connection VUS-PL-V140 2

Spare Penetration Test Connection VUS-PL-V141 2

Spare Penetration Test Connection VUS-PL-V142 2

VWS Supply Containment Penetration IRC Test Connection/Vent VWS-PL-V424 2

VWS Return Containment Penetration ORC Test Connection/Vent VWS-PL-V425 2

Heat Exchangers Normal Residual Heat Removal Heat Exchanger A RNS-ME-01A 3

Normal Residual Heat Removal Heat Exchanger B RNS-ME-01B 3

Tanks Spent Fuel Pool FHS-MT-01 3

Fuel Transfer Canal FHS-MT-02 3

Spent Fuel Cask Loading Pit FHS-MT-05 3

Passive Containment Cooling Water Storage Tank PCS-MT-01 3

Water Distribution Bucket PCS-MT-03 3

Water Collection Troughs PCS-MT-04 3

Passive RHR Heat Exchanger PXS-ME-01 3

Accumulator Tank A PXS-MT-01A 3

Accumulator Tank B PXS-MT-01B 3

Core Makeup Tank A PXS-MT-02A 3

Core Makeup Tank B PXS-MT-02B 3

In-Containment Refueling Water Storage Tank PXS-MT-03 3

Emergency Air Storage Tank 01 VES-MT-01 3

Emergency Air Storage Tank 02 VES-MT-02 3

Emergency Air Storage Tank 03 VES-MT-03 3

Emergency Air Storage Tank 04 VES-MT-04 3

Table 3I.6-3 (Sheet 30 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-69 Revision 0 Turkey Point Units 6 & 7 - IFSAR Emergency Air Storage Tank 05 VES-MT-05 3

Emergency Air Storage Tank 06 VES-MT-06 3

Emergency Air Storage Tank 07 VES-MT-07 3

Emergency Air Storage Tank 08 VES-MT-08 3

Emergency Air Storage Tank 09 VES-MT-09 3

Emergency Air Storage Tank 10 VES-MT-10 3

Emergency Air Storage Tank 11 VES-MT-11 3

Emergency Air Storage Tank 12 VES-MT-12 3

Emergency Air Storage Tank 13 VES-MT-13 3

Emergency Air Storage Tank 14 VES-MT-14 3

Emergency Air Storage Tank 15 VES-MT-15 3

Emergency Air Storage Tank 16 VES-MT-16 3

Emergency Air Storage Tank 17 VES-MT-17 3

Emergency Air Storage Tank 18 VES-MT-18 3

Emergency Air Storage Tank 19 VES-MT-19 3

Emergency Air Storage Tank 20 VES-MT-20 3

Emergency Air Storage Tank 21 VES-MT-21 3

Emergency Air Storage Tank 22 VES-MT-22 3

Emergency Air Storage Tank 23 VES-MT-23 3

Emergency Air Storage Tank 24 VES-MT-24 3

Emergency Air Storage Tank 25 VES-MT-25 3

Emergency Air Storage Tank 26 VES-MT-26 3

Emergency Air Storage Tank 27 VES-MT-27 3

Emergency Air Storage Tank 28 VES-MT-28 3

Emergency Air Storage Tank 29 VES-MT-29 3

Emergency Air Storage Tank 30 VES-MT-30 3

Table 3I.6-3 (Sheet 31 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-70 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes:

1.

Rugged AP1000 safety-related equipment with no moving parts required in demonstrating functional operability during a seismic event is considered to be not sensitive to HRHF seismic loadings. Seismic qualification is based on the seismic loads associated with the mounting location of the safety-related equipment as a minimum. AP1000 CSDRS seismic loads at the mounting location of the safety-related equipment produces comparable or higher equipment stresses and deflections than the HRHF seismic loadings based on the work reported in APP-GW-GLR-115, Effect of High Frequency Seismic Content on SSCs. For rugged safety-related line-mounted equipment being qualified by test, seismic testing will be performed in compliance with IEEE Standard 382-1996 with a required input motion (RIM) curve extended to 64 Hz typically to a peak acceleration of 6g.

2.

AP1000 safety-related valves are seismic qualified in accordance with ASME code for structural integrity to a maximum acceleration of 6g in all three principal orthogonal axes. AP1000 CSDRS seismic loads at the mounting location of the safety-related equipment produce comparable or higher equipment stresses and deflections than the HRHF seismic loadings based on the work reported in APP-GW-GLR-115, Effect of High Frequency Seismic Content on SSCs. For rugged safety-related line-mounted equipment being qualified by test, seismic testing will be performed in compliance with IEEE Standard 382-1996 with a required input motion (RIM) curve extended to 64 Hz typically to a peak acceleration of 6g.

3.

Seismic qualification is based on structural integrity alone to the seismic loadings associated with the mounting location of the safety-related equipment as a minimum. AP1000 CSDRS seismic loads at the mounting location of the safety-related equipment produce comparable or higher equipment stresses and deflections than the HRHF seismic loadings based on the work reported in APP-GW-GLR-115, Effect of High Frequency Seismic Content on SSCs.

4.

Seismic qualification is not required.

Emergency Air Storage Tank 31 VES-MT-31 3

Emergency Air Storage Tank 32 VES-MT-32 3

Main Feed Pump A Status ECS-ES-3-XXX 4

Main Feed Pump B Status ECS-ES-4-XXX 4

Main Feed Pump C Status ECS-ES-5-XXX 4

Table 3I.6-3 (Sheet 32 of 32)

List Of AP1000 Safety-Related Electrical and Mechanical Equipment Not High Frequency Sensitive Description AP1000 Tag Number Comment

3I-71 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 3I.1-1 Comparison of Horizontal AP1000 CSDRS and HRHF Envelope Response Spectra AP1000 Horizontal Spectra Comparison 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 0.1 1

10 100 Frequency (Hz)

Acceleration (g)

HRHF GMRS AP1000 CSDRS

3I-72 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 3I.1-2 Comparison of Vertical AP1000 CSDRS and HRHF Envelope Response Spectra AP1000 Vertical Spectra Comparison 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 0.1 1

10 100 Frequency (Hz)

Acceleration (g)

HRHF GMRS AP1000 CSDRS