RAIO-1018-62331 October 26, 2018 Docket No.52-048 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738
SUBJECT:
NuScale Power, LLC Response to NRC Request for Additional Information No.
353 (eRAI No. 9304) on the NuScale Design Certification Application
REFERENCE:
U.S. Nuclear Regulatory Commission, "Request for Additional Information No.
353 (eRAI No. 9304)," dated January 29, 2018 The purpose of this letter is to provide the NuScale Power, LLC (NuScale) response to the referenced NRC Request for Additional Information (RAI).
The Enclosures to this letter contain NuScale's response to the following RAI Question from NRC eRAI No. 9304:
- 06.02.01 .03-1 is the proprietary version of the NuScale Response to NRC RAI No. 353 (eRAI No.
9304 ). NuScale requests that the proprietary version be withheld from public disclosure in accordance with the requirements of 10 CFR § 2.390. The enclosed affidavit (Enclosure 3) supports this request. Enclosure 2 is the nonproprietary version of the NuScale response.
This letter and the enclosed responses make no new regulatory commitments and no revisions to any existing regulatory commitments.
If you have any questions on this response, please contact Paul lnfanger at 541-452-7351 or at pinfanger@nuscalepower.com.
!}(µ~
Sincerely, Jennie Wil<e Manager, Licensing NuScale Power, LLC Distribution: Gregory Cranston, NRC, OWFN-8G9A Omid Tabatabai, NRC, OWFN-8G9A Samuel Lee, NRC, OWFN-8G9A Enclosure 1: NuScale Response to NRC Request for Additional Information eRAI No. 9304, proprietary NuScale Power, LLC 1100 NE Circle Blvd. , Suite 200 Corvalis, Oregon 97330 , Office: 541.360.0500 , Fax: 541.207.3928 www.nuscalepower.com
RAIO-1018-62331 : NuScale Response to NRC Request for Additional Information eRAI No. 9304, nonproprietary : Affidavit of Jennie Wike, AF-1018-62332 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
NuScale Confidential, Proprietary Class 2 RAIO-1018-62331 :
NuScale Response to NRC Request for Additional Information eRAI No. 9304, proprietary NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
NuScale Response to NRC Request for Additional Information eRAI No. 9304, nonproprietary NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
Response to Request for Additional Information Docket No.52-048 eRAI No.: 9304 Date of RAI Issue: 01/29/2018 NRC Question No.: 06.02.01.03-1 General Design Criterion (GDC) 50, Containment Design Basis, requires in part that the containment be designed with sufficient margin, and that the containment and its associated systems be designed to accommodate, without exceeding the design leakage rate, the calculated pressure and temperature conditions resulting from any loss-of-coolant accident (LOCA). Part of this demonstration involves a calculation of the mass and energy release into containment.
Section 8.0 of TR-0516-49084, Containment Response Analysis Methodology Technical Report, provides tabulated appendices of important modeling inputs for the mass and energy release calculations, including the actual mass and energy release values over time for selected cases. The TR states that cases are provided for the limiting LOCA, limiting peak containment pressure case, and limiting secondary side break case. However, staff only found data for the limiting peak pressure and secondary side break cases. Additionally, the data sets did not appear to have a robust time step sampling, especially early in the transient. Staff understands that this is an artifact of the chosen data for display, and that the NRLEAP5 calculation has additional data (as the data set is not being passed between codes). In order to come to a finding regarding the suitability of the mass and energy release cases presented in the TR and to assist the staff in performing confirmatory analysis with a separate containment code, staff requests that NuScale update TR-0516-49084 to: 1) include a mass and energy release table for the limiting peak pressure case (Case 5 in the TR), the limiting LOCA temperature case (Case 2 in the TR), and the limiting secondary side release (the MSLB); and 2) demonstrate the tables provided have sufficiently resolved time step sampling for the duration of the break (i.e.
by showing that the NRELAP5 mass and energy release does not substantially differ from the provided data points).
NuScale Nonproprietary
NuScale Response:
The Containment Response Analysis Methodology Technical Report, TR-0516-49084, Revision 0 has been updated to reflect the updated containment response analysis results determined using NRELAP5, Version 1.4. As part of the update, Table 8-1, "Limiting Peak Pressure Case -
Mass and Energy Release" has been updated, Table 8-2, "Limiting Peak Wall Temperature Case - Mass and Energy Release" has been added and Table 8-3, "Limiting Secondary Break Peak Pressure - Mass and Energy Release" (previously Table 8-2) was also updated. The updated Tables provide data at one second increments during portions of the transient where the mass and energy release rates are varying rapidly by a large amount, and at larger time increments for more stable portions of the transients.
The updated Tables in TR-0516-49084 include a sufficient number of time steps as depicted by the following Figures overlaying a plot of the updated TR-0516-49084 Table data over a plot of the total mass release rate and total energy release rate data at one second intervals, provided by the response to eRAI 9357. These Figures show that the two data sets align, thereby demonstrating that a sufficient number of time steps are provided by the updated Tables in TR-0516-49804.
NuScale Nonproprietary
Figure 1: Peak CNV Pressure Case: Table 8-1 vs. Full Data Set NuScale Nonproprietary
Figure 2: Peak CNV Pressure Case: Table 8-1 vs. Full Data Set NuScale Nonproprietary
Figure 3: Peak CNV Pressure Case: Table 8-1 vs. Full Data Set NuScale Nonproprietary
Figure 4: Peak CNV Pressure Case: Table 8-1 vs. Full Data Set NuScale Nonproprietary
Figure 5: Peak CNV Temperature Case: Table 8-2 vs. Full Data Set NuScale Nonproprietary
Figure 6: Peak CNV Temperature Case: Table 8-2 vs. Full Data Set NuScale Nonproprietary
Figure 7: Peak CNV Temperature Case: Table 8-2 vs. Full Data Set NuScale Nonproprietary
Figure 8: Peak CNV Temperature Case: Table 8-2 vs. Full Data Set NuScale Nonproprietary
Figure 9: Secondary Side Peak CNV Pressure Case: Table 8-3 vs. Full Data Set NuScale Nonproprietary
Figure 10: Secondary Side Peak CNV Pressure Case: Table 8-3 vs. Full Data Set NuScale Nonproprietary
Figure 11: Secondary Side Peak CNV Pressure Case: Table 8-3 vs. Full Data Set NuScale Nonproprietary
Figure 12: Secondary Side Peak CNV Pressure Case: Table 8-3 vs. Full Data Set Impact on DCA:
Technical Report TR-0516-49084, Containment Response Analysis Methodology, TR-0516-49084 has been revised as described in the response above and as shown in the markup provided in this response.
NuScale Nonproprietary
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Containment Response Analysis Methodology Technical Report January, 2017 Draft Revision 10 Docket: PROJ0769 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 www.nuscalepower.com
© Copyright 2018 by NuScale Power, LLC
© Copyright 2018 by NuScale Power, LLC i
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 COPYRIGHT NOTICE This report has been prepared by NuScale Power, LLC, and bears a NuScale Power, LLC, copyright notice. No right to disclose, use, or copy any of the information in this report, other than by the U.S.
Nuclear Regulatory Commission (NRC), is authorized without the express, written permission of NuScale Power, LLC.
The NRC is permitted to make the number of copies of the information contained in this report that is necessary for its internal use in connection with generic and plant-specific reviews and approvals, as well as the issuance, denial, amendment, transfer, renewal, modification, suspension, revocation, or violation of a license, permit, order, or regulation subject to the requirements of 10 CFR 2.390 regarding restrictions on public disclosure to the extent such information has been identified as proprietary by NuScale Power, LLC, copyright protection notwithstanding. Regarding nonproprietary versions of these reports, the NRC is permitted to make the number of copies necessary for public viewing in appropriate docket files in public document rooms in Washington, DC, and elsewhere as may be required by NRC regulations. Copies made by the NRC must include this copyright notice and contain the proprietary marking if the original was identified as proprietary.
© Copyright 2018 by NuScale Power, LLC ii
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Department of Energy Acknowledgement and Disclaimer This material is based upon work supported by the Department of Energy under Award Number DE-NE0000633.
This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.
© Copyright 2018 by NuScale Power, LLC iii
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 CONTENTS Abstract ....................................................................................................................................... 1 Executive Summary .................................................................................................................... 2 1.0 Introduction ..................................................................................................................... 4 1.1 Purpose ................................................................................................................. 4 1.2 Scope .................................................................................................................... 4 1.3 Abbreviations ......................................................................................................... 5 2.0 Background ..................................................................................................................... 6 2.1 Regulatory Requirements ...................................................................................... 6 2.1.1 10 CFR 50 Appendix A - General Design Criteria for Nuclear Power Plants .................................................................................................................... 6 2.1.2 Regulatory Guide 1.203 ........................................................................................ 7 2.1.3 Design Specific Review Standard for NuScale Small Modular Reactor Design ................................................................................................................... 8 3.0 Analysis ......................................................................................................................... 22 3.1 Modeling Software ............................................................................................... 22 3.2 NRELAP5 Base Simulation Model Development ................................................ 22 3.2.1 RELAP5-3D© ....................................................................................................... 22 3.2.2 RELAP5-3D© Quality Assurance ......................................................................... 22 3.2.3 NRELAP5 Simulation Models .............................................................................. 24 3.2.4 Containment Reponse Analysis Base Model Development ................................ 31 3.3 Containment Response Analysis Methodology for Primary System Release Events ................................................................................................... 45 3.3.1 Primary System Mass and Energy Release Methodology .................................. 45 3.4 Secondary System Containment Response Analysis Methodology .................... 49 3.4.1 Steamline Break Mass and Energy Release Methodology ................................. 49 3.4.2 Feedwater Line Break Mass and Energy Methodology ....................................... 51 3.5 Initial and Boundary Conditions ........................................................................... 53 3.5.1 Primary System Release Event Initial Conditions ............................................... 53 3.5.2 Primary System Release Event Boundary Conditions ........................................ 55 3.5.3 Main Steam Line Break Initial Conditions ............................................................ 59 3.5.4 Main Steam Line Break Boundary Conditions ..................................................... 60 3.5.5 Feedwater Line Break Initial Conditions .............................................................. 63 3.5.6 Feedwater Line Break Boundary Conditions ....................................................... 63
© Copyright 2018 by NuScale Power, LLC iv
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 4.0 Qualification and Assessment .................................................................................... 64 4.1 Assessment of Methodology and Data ................................................................ 64 4.1.1 Primary System Release Effects Code and Model Qualification ......................... 64 4.1.2 Secondary System Pipe Break Effects Code and Model Qualification................ 65 4.2 Testing Results .................................................................................................... 66 4.2.1 NuScale Integral System Test Facility Testing ..................................................... 66 5.0 Results ........................................................................................................................... 67 5.1 Primary System Release Scenario Containment Response Analysis ................. 67 5.1.1 Analysis Approach ............................................................................................... 67 5.1.2 Reference Analysis and Sensitivity Results......................................................... 68 5.1.3 Primary Release Scenario Pressure and Temperature Results .......................... 68 5.2 Main Steamline Break Pressure and Temperature Results ............................... 113 5.3 Feedwater Line Break Pressure and Temperature Results ............................... 129 5.4 Margin Assessment ........................................................................................... 147 5.4.1 Atmospheric Pressure ....................................................................................... 147 5.4.2 Decay Heat Removal System Availability .......................................................... 150 5.4.3 Conclusion ......................................................................................................... 150 6.0 Summary and Conclusions ........................................................................................ 151 7.0 References ................................................................................................................... 153 7.1 Source Documents ............................................................................................ 153 7.2 Reference Documents ....................................................................................... 153 8.0 Appendicies ................................................................................................................. 154 8.1 Mass and Energy Input ..................................................................................... 154 8.2 Heat Sink Tables................................................................................................ 154 8.2.1 Listing of Passive Heat Sinks ............................................................................ 167 8.2.2 Modeling of Passive Heat Sinks ........................................................................ 167 8.2.3 Thickness Groups ............................................................................................. 167 8.2.4 Properties of Passive Heat Sink Materials ........................................................ 168 TABLES Table 1-1 Abbreviations ......................................................................................................... 5 Table 2-1 Compliance with Design Specific Review Standard Section 6.2.1 ........................ 8 Table 2-2 Compliance with Design Specific Review Standard Section 6.2.1.1.A................ 10 Table 2-3 Compliance with Design Specific Review Standard Section 6.2.1.3 ................... 13
© Copyright 2018 by NuScale Power, LLC v
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 2-4 Compliance with Design Specific Review Standard Section 6.2.1.4 ................... 19 Table 3-1 New NRELAP5 models ....................................................................................... 23 Table 3-2 Containment vessel and reactor pool heat transfer modeling ............................. 40 Table 3-3 Primary system mass and energy release scenarios .......................................... 48 Table 3-4 Primary system initial conditions ......................................................................... 53 Table 3-5 Containment vessel and reactor pool initial conditions........................................ 54 Table 3-6 Primary system boundary conditions................................................................... 56 Table 3-7 Secondary system initial conditions .................................................................... 60 Table 3-8 Boundary conditions for the main steam line break containment response analysis methodology .......................................................................................... 61 Table 5-1 Initial conditions for primary system release event analyses............................... 69 Table 5-2 Case 1 sequence of events - reactor coolant system discharge line break loss-of-coolant accident .................................................................................................. 70 Table 5-3 Case 2 sequence of events for limiting containment vessel temperature event - reactor coolant system injection line break loss-of-coolant accident ....... 75 Table 5-4 Case 3 sequence of events - RPV high point degasification line break loss-of-coolant accident ....................................................................................... 91 Table 5-5 Case 4 sequence of events - inadvertent reactor vent valve opening event ...... 94 Table 5-6 Case 5 sequence of events - inadvertent reactor recirculation valve opening event .................................................................................................................... 99 Table 5-7 Main steam line break sequence of events ....................................................... 115 Table 5-8 Feedwater line break sequence of events ......................................................... 132 Table 8-1 Limiting Peak Pressure Case - Mass and Energy Release .............................. 154 Table 8-2 Limiting Peak Wall Temperature Case - Mass and Energy Release ................ 159 Table 8-3 Limiting Secondary Break Peak Pressure Mass and Energy Release .............. 165 Table 8-4 Passive heat sinks ............................................................................................. 167 Table 8-5 Thickness groups .............................................................................................. 167 Table 8-6 Physical properties of passive heat sink materials ............................................ 168 FIGURES Figure 3-1 NRELAP5 NuScale Power Module noding diagram ............................................ 27 Figure 3-2 NRELAP5 nodalization for non-loss-of-coolant accident evaluation model......... 29 Figure 3-3 NuScale module during power operation ............................................................ 32 Figure 3-4 NuScale module during emergency core cooling system operation.................... 32 Figure 3-5 NRELAP5 nodalization for reactor coolant system discharge line break loss-of-coolant accident ....................................................................................... 34 Figure 3-6 NRELAP5 nodalization for reactor coolant system injection line break loss-of-coolant accident ....................................................................................... 35 Figure 3-7 NRELAP5 nodalization for pressurizer spray supply line break and RPV high point vent degasification line loss-of-coolant accident......................................... 36 Figure 3-8 NRELAP5 reactor pool model ............................................................................. 39 Figure 3-9 Main steam lIne break model .............................................................................. 43 Figure 3-10 Feedwater line break model ................................................................................ 44 Figure 5-1 Case 1 containment vessel pressure - reactor coolant system discharge line break loss-of-coolant accident ............................................................................. 71 Figure 5-2 Case 1 containment vessel wall temperature - reactor coolant system discharge line break loss-of-coolant accident ...................................................................... 72
© Copyright 2018 by NuScale Power, LLC vi
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-3 Case 2 primary system pressure - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) .................................................... 76 Figure 5-4 Case 2 pressurizer level - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) .................................................... 77 Figure 5-5 Case 2 riser level - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) ............................................................................ 78 Figure 5-6 Case 2 primary temperatures - reactor coolant system injection line break loss-of-coolant accident ....................................................................................... 79 Figure 5-7 Case 2 break and emergency core cooling system mass flowrate - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) ........................................................................................... 80 Figure 5-8 Case 2 integrated loss-of-coolant accident and emergency core cooling system mass release - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) ........................................................................... 81 Figure 5-9 Case 2 integrated loss-of-coolant accident and emergency core cooling system energy release - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) ........................................................................... 82 Figure 5-10 Case 2 containment vessel pressure - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) ......................................... 83 Figure 5-11 Case 2 containment vessel level - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) ................................................... 84 Figure 5-12 Case 2 containment vessel vapor temperature - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) .................... 85 Figure 5-13 Case 2 containment vessel wall temperature profile -reactor coolant system injection line break loss-of-coolant accident (peak pressure case) .................... 86 Figure 5-14 Case 2 reactor pool temperatures - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) ................................................... 87 Figure 5-15 Case 2 energy balance - reactor coolant system injection lIne break loss-of-coolant accident (peak pressure case) ................................................... 88 Figure 5-16 Case 2 containment vessel pressure - reactor coolant system injection line break loss-of-coolant accident (peak CNV wall temperature case) .................... 89 Figure 5-17 Case 2 containment vessel peak wall temperature - reactor coolant system injection line break loss-of-coolant accident (peak CNV wall temperature case) ............................................................................................... 90 Figure 5-18 Case 3 containment vessel pressure - high point vent line break loss-of-coolant accident ............................................................................................................... 92 Figure 5-19 Case 3 containment vessel wall temperature - high point vent line break loss-of-coolant accident ....................................................................................... 93 Figure 5-20 Case 4 containment vessel pressure - inadvertent reactor vent valve opening event .................................................................................................................... 95 Figure 5-21 Case 4 containment vessel wall temperature - inadvertent reactor vent valve opening event ...................................................................................................... 96 Figure 5-22 Case 5 primary pressure - inadvertent reactor recirculation valve opening event .................................................................................................................. 100 Figure 5-23 Case 5 pressurizer level - inadvertent reactor recirculation valve opening event
.......................................................................................................................... 101 Figure 5-24 Case 5 riser level - inadvertent reactor recirculation valve opening event ........ 102 Figure 5-25 Case 5 primary temperature - inadvertent reactor recirculation valve opening event .................................................................................................................. 103
© Copyright 2018 by NuScale Power, LLC vii
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-26 Case 5 loss-of-coolant accident and emergency core cooling system flowrate - inadvertent reactor recirculation valve opening event ....................... 104 Figure 5-27 Case 5 integrated loss-of-coolant accident and emergency core cooling system mass flow rate - inadvertent reactor recirculation valve opening event .................................................................................................... 105 Figure 5-28 Case 5 integrated loss-of-coolant accident and emergency core cooling system energy release - inadvertent reactor recirculation valve opening event .................................................................................................... 106 Figure 5-29 Case 5 containment vessel pressure - inadvertent reactor recirculation valve opening event (overall limiting pressure case) .................................................. 107 Figure 5-30 Case 5 containment vessel level - inadvertent reactor recirculation valve opening event .................................................................................................... 108 Figure 5-31 Case 5 containment vessel vapor temperature - inadvertent reactor recirculation valve opening event ...................................................................... 109 Figure 5-32 Case 5 containment vessel wall temperature - inadvertent reactor recirculation valve opening event ...................................................................... 110 Figure 5-33 Case 5 containment vessel wall temperature profile - inadvertent reactor recirculation valve opening event ...................................................................... 111 Figure 5-34 Case 5 reactor pool temperature - inadvertent reactor recirculation valve opening event .................................................................................................... 112 Figure 5-35 Case 5 energy balance - inadvertent reactor recirculation valve opening event .................................................................................................... 113 Figure 5-36 Main steam line break steam generator pressure ............................................. 116 Figure 5-37 Main steam line break primary temperature ...................................................... 117 Figure 5-38 Main steam line break primary system pressure ............................................... 118 Figure 5-39 Main steam line break pressurizer level ............................................................ 119 Figure 5-40 Main steam line break and emergency core cooling system flowrate ............... 120 Figure 5-41 Main steam line break and emergency core cooling system integrated mass release ............................................................................................................... 121 Figure 5-42 Main steam line break integrated energy release.............................................. 122 Figure 5-43 Main steam line break containment vessel pressure......................................... 123 Figure 5-44 Main steam line break containment vessel vapor temperature ......................... 124 Figure 5-45 Main steam line break containment vessel wall temperature ............................ 125 Figure 5-46 Main steam line break containment vessel level ............................................... 126 Figure 5-47 Main steam line break containment vessel wall temperature profile ................. 127 Figure 5-48 Main steam line break reactor pool temperature ............................................... 128 Figure 5-49 Main steam line break energy balance .............................................................. 129 Figure 5-50 Feedwater line break steam generator pressure ............................................... 133 Figure 5-51 Feedwater line break primary temperature........................................................ 134 Figure 5-52 Feedwater line break pressurizer level .............................................................. 135 Figure 5-53 Feedwater line break riser level ........................................................................ 136 Figure 5-54 Feedwater line break primary system pressure................................................. 137 Figure 5-55 Feedwater line break and emergency core cooling system flowrate ................. 138 Figure 5-56 Feedwater line break and ECCS integrated mass release................................ 139 Figure 5-57 Feedwater line break and ECCS integrated energy release ............................. 140 Figure 5-58 Feedwater line break containment vessel pressure .......................................... 141 Figure 5-59 Feedwater line break containment vessel vapor temperature ........................... 142 Figure 5-60 Feedwater line break containment vessel wall temperature.............................. 143 Figure 5-61 Feedwater line break containment vessel level ................................................. 144
© Copyright 2018 by NuScale Power, LLC viii
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-62 Feedwater line break containment vessel wall temperature profile ................... 145 Figure 5-63 Feedwater line break reactor pool temperature................................................. 146 Figure 5-64 Feedwater line break energy balance ............................................................... 147
© Copyright 2018 by NuScale Power, LLC ix
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Abstract This report presents the NuScale Power, LLC, methodology used to analyze the mass and energy release into the containment vessel (CNV) for the spectrum of design basis transients and accidents, and the resulting pressure and temperature response of the CNV. The NuScale Power Module (NPM) limiting peak pressure and temperature results determined using the methodology are presented.
This report demonstrates that the NuScale Power Module containment vessel design accommodates the limiting loss-of-coolant and non-loss-of-coolant events, with respect to peak accident pressure and temperature, including sufficient margin. This report also demonstrates conformance to 10 CFR 50 Appendix A, General Design Criteria (GDC) 16 and 50, and Principal Design Criterion (PDC) 38 along with compliance with relevant Acceptance Criteria given by the Design Specific Review Standard for NuScale Small Modular Reactor Design, Section 6.2.1 (Reference 7.1.4).
This report is intended to be incorporated by reference into Design Certification Application Section 6.2.
© Copyright 2018 by NuScale Power, LLC 1
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Executive Summary This report presents the NuScale Power, LLC, (NuScale) methodology used to analyze the mass and energy release into the containment vessel (CNV) for the spectrum of design basis transients and accidents, and the resulting pressure and temperature response of the CNV. The NuScale Power Module (NPM) limiting peak pressure and temperature results determined using the methodology are presented.
The containment response analysis methodology uses the NRELAP5 thermal-hydraulic code, which is a NuScale-modified version of the RELAP5-3D© v 4.1.3 code used for loss-of-coolant accident (LOCA) and non-LOCA transient and accident analyses, including the response of the CNV.
The NRELAP5 model used to model NPM performance for primary system LOCA and emergency core cooling system valve-opening event analyses is similar with to the model used in the LOCA evaluation model, described by Reference 7.2.1. The NRELAP5 model used for secondary system pipe-break analysis in the containment response analysis methodology is consistent with similar to the non-LOCA model described by the Non-LOCA Evaluation Model Report (Ref: 7.2.2).
Changes made to these models that maximize containment pressure and temperature response to primary and secondary system release events are described in this report. These changes conservatively maximize the mass and energy release and minimize the performance of the containment heat removal system and are consistent with acceptance criteria given by Design Specific Review Standard Section 6.2.1.3 (Ref: 7.1.6) and Design Specific Review Standard Section 6.2.1.4 (Ref: 7.1.7).
Other differences exist between the NRELAP5 model used to model NPM performance for primary system LOCA and emergency core cooling system valve-opening event analyses and the containment analysis model. These modeling differences, identified in Section 3.2.4.1, have a negligible impact on the CNV analysis results.
Initial and boundary conditions for the spectrum of primary system release containment response analyses and secondary system pipe break analyses are selected to ensure a conservative CNV peak pressure and peak temperature result. These initial and boundary conditions are described in this report, along with the rationale for their selection.
The results of the NRELAP5 limiting analyses using the containment response analysis methodology are presented in this report. These analyses cover the spectrum of primary system mass and energy release scenarios for the NPM, and secondary system pipe break scenarios.
The limiting LOCA peak pressure and CNV wall temperature are a result of the reactor coolant system (RCS) injection line break. The LOCA limiting peak CNV wall temperature is approximately 523526 degrees F and it results from a reactor coolant system injection line break case, with a loss of normal alternating current (AC) power. The LOCA limiting peak internal pressure is approximately 921959 psia, which also results from a reactor coolant system injection line break case with a loss of normal AC and DC power. The LOCA event peak CNV pressure is below the CNV design pressure of 10001075 psia. The LOCA peak CNV pressure and wall temperature bound the main steamline break (MSLB) and feedwater line break (FWLB) results.
© Copyright 2018 by NuScale Power, LLC 2
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 The overall limiting peak CNV accident pressure is approximately 951986 psia, which is approximately 8 percent below the containment design pressure of 1075 psia. It results from an inadvertent reactor recirculation valve opening anticipated operational occurrence with a loss of normal AC and direct current (DC) power. The peak pressure of the limiting anticipated operational occurrence is also less than the CNV design pressure of 1000 psia. The CNV pressure for this limiting case is reduced to below 50 percent of the peak value in less than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, demonstrating adequate NPM containment heat removal.
Section 5.4 discusses margin in the NPM design that is not included in the CNV design pressure rating or modeled in the containment response analyses. Design factors conservatively not credited include atmospheric pressure acting against the CNV shell stress margins, CNV cladding materialexterior surface and the availability of the decay heat removal system (DHRS).
The containment response analysis methodology demonstrates that the NPM design has adequate margin to design limits and that it satisfies the requirements of General Design Criteria (GDC) 16, 50, and Principal Design Criterion (PDC) 38.
© Copyright 2018 by NuScale Power, LLC 3
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 1.0 Introduction 1.1 Purpose The purpose of this report is to present the NuScale Power, LLC, methodology used to analyze the mass and energy (M&E) release into the containment vessel (CNV) for the spectrum of design-basis transients and accidents and the resulting pressure and temperature response of the CNV, and to present the NuScale Power Module (NPM)-
limiting peak pressure and temperature results that are determined using the methodology.
1.2 Scope The scope of the Containment Response Analysis Technical Report comprises the M&E release from the spectrum of primary system and secondary system design basis transients and accidents and the resulting CNV pressure and temperature response. The duration of the analyses is sufficient to establish the CNV peak pressure and peak temperature for all events, and to demonstrate the decrease in pressure to one-half of the peak value within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The NRELAP5 code, described in Reference 7.2.1, is used in this methodology. The simulation models used in the containment response analysis methodology are similar to the models used in the NuScale LOCA and non-LOCA methdoologies (Reference 7.2.1 and Reference 7.2.2). This report documents the differences compared to those methodologies and provides bounding analysis results for the limiting accident scenarios.
Operation at rated power is the bounding initial condition for the limiting CNV pressure and temperature event scenarios for the NPM. Operation at rated power is the bounding initial condition because it has the maximum stored energy and decay heat. For the NPM, reduced power levels and shutdown conditions are non-limiting and do not need to be analyzed specifically.
Chapter 2.0 describes the regulatory guidance that is applicable to the scope of the containment response analysis methodology and summarizes how the methodology meets the guidance. Chapter 3.0 describes the NRELAP5 computer code along with the qualification of the code for the scope of the containment response analysis methodology.
Chapter 3.0 also describes the NRELAP5 model of the NPM used in the containment response analysis methodology. Chapter 4.0 describes validation and verification of the containment response analysis methodology as well as primary and secondary release event models, including the code and model qualification and conservativisms. Chapter 5.0 presents the containment response analysis methodology for primary system release events, the limiting scenarios and associated analysis results, and nominal case results demonstrating conservatism in assumed certain initial conditions. Chapter 5.0 also presents the containment response analysis methodology for secondary-system pipe breaks along with associated analysis results. Chapter 6.0 presents the report summary and conclusions.
The methodology for simulation of the longer-term M&E release and CNV and NPM response that is used for establishing the equipment qualification (EQ) pressure and
© Copyright 2018 by NuScale Power, LLC 4
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 temperature envelopes, and to demonstrate the long-term cooling capabilities of the NPM, are not included within the scope of this report.
1.3 Abbreviations Table 1-1 Abbreviations Term Definition AC alternating current ASME American Society of Mechanical Engineers ANS American Nuclear Society BPVC Boiler and Pressure Vessel Code CFR Code of Federal Regulations CNV containment vessel CVCS chemical and volume control system DC direct current DHRS decay heat removal system DSRS Design Specific Review Standard ECCS emergency core cooling system FSAR Final Safety Analysis Report FWIV feedwater isolation valve FWLB feedwater line break FWRV feedwater regulating valve GDC General Design Criteria IAB inadvertent actuation block ID inside diameter LOCA loss-of-coolant accident M&E mass and energy MSIV main steam isolation valve MSLB main steam line break NIST-1 NuScale Integral System Test Facility NPM NuScale Power Module NRC U. S. Nuclear Regulatory Commission OD outer diameter PDC Principal Design Criterion PIRT phenomena identification and ranking table PWR pressurized water reactor RCS reactor coolant system RPV reactor pressure vessel RRV reactor recirculation valve RSV reactor safety valve RVV reactor vent valve SG steam generator SMR small modular reactor SRP Standard Review Plan
© Copyright 2018 by NuScale Power, LLC 5
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 2.0 Background The CNV is a compact, steel pressure vessel that consists of an upright cylinder with top and bottom head closures. The CNV is partially immersed in a below-grade reactor pool that provides a passive heat sink and is absent of internal sumps or subcompartments that could entrap water or gases. The CNV and the reactor pool are housed within a Seismic Category 1 Reactor Building. The unique nature of the NPM design necessitates development of a specific containment response analysis methodology.
This technical report describes the thermal-hydraulic accident analysis methodology for primary and secondary system M&E releases into the CNV of the NPM, and the resulting pressure and temperature response of the CNV. This report presents the bases for the analysis methodology and results in support of Chapter 6 of the NuScale Final Safety Analysis Report (FSAR). The containment response analysis methodology and CNV peak pressure and temperature results are compared to applicable regulatory guidance, including the Design Specific Review Standard for NuScale Small Modular Reactor (SMR)
Design, Section 6.2.1 (Ref: 7.1.4). A spectrum of M&E release events is analyzed that bounds all of the LOCAs and valve-opening transients in the primary system and all secondary-system pipe-break accidents. The containment response analysis methodology uses conservative initial conditions and boundary conditions to ensure overall conservative results. The limiting results are shown to be less than the design pressure (10001075 psia) and the design temperature (550 degrees F) of the CNV.
The qualification of the LOCA and non-LOCA methodologies presented in References 7.2.1 and 7.2.2, in particular the comparisons to separate effects tests and integral effects tests, are applicable for the containment response analysis methodology presented in this report. The differences in the NRELAP5 simulation models used in the containment response analysis methodology as compared to the LOCA and non-LOCA models, along with the rationale for the selection of conservative initial and boundary conditions, are the subject of this report. Analysis results are presented for the limiting cases, along with nominal condition case results, demonstrating conservatism in certain initial conditions.
2.1 Regulatory Requirements The Nuclear Regulatory Commission (NRC) regulations and regulatory guidance applicable to the containment response analysis methodology are described in this section. The elements of the containment response analysis methodology that address each of these regulations and requirements are discussed.
2.1.1 10 CFR 50 Appendix A - General Design Criteria for Nuclear Power Plants The General Design Criteria (GDC) for Nuclear Power Plants, Appendix A to 10 CFR 50 (Ref: 7.1.2), include the NRC regulations applicable to the containment response methodology. Compliance with GDC 16 and 50 and PDC 38 is as follows:
General Design Criterion 16 - The analyses performed per the containment response analysis methodology are used to establish the limiting CNV pressure and temperature conditions resulting from the spectrum of design-basis primary system and secondary system M&E releases resulting from pipe breaks and valve actuations. The CNV is
© Copyright 2018 by NuScale Power, LLC 6
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 designed to ensure that the design pressure and temperature limit are not exceeded as demonstrated by the analysis results.
Principal Design Criterion 38 - The analyses performed per the containment response analysis methodology establish the performance of NPM containment heat removal and demonstrate that the containment peak pressure and temperature are rapidly reduced.
The methodology addresses LOCAs, valve-opening events and secondary pipe breaks.
Following containment isolation and opening of the ECCS valves, the containment heat removal function is passive and does not require electric power. The requirement to rapidly reduce the containment pressure and temperature is demonstrated by the peak pressure decreasing to less than 50 percent of the peak value consistent with Design Specific Review Standard (DSRS) Section 6.2.1.1.A (Ref: 7.1.5). Potential single failures have been considered in the methodology, and the results of the analyses show that the safety functions can be performed including the limiting single failure.
General Design Criterion 50 - The analyses performed per the containment response analysis methodology demonstrate that sufficient margin to the CNV design pressure and temperature is maintained. The methodology explicitly models all energy sources including energy in the steam generators (SGs). However, the energy from the post-LOCA oxidation of the cladding that is typical of light water reactors is not applicable to the NuScale design and is not included. Calculated cladding temperatures for design basis LOCAs are below the level where cladding oxidation occurs on a time scale of a LOCA event for the NPM. Therefore, this requirement is satisfied by the design that precludes fuel temperature reaching critical heat flux and any significant fuel cladding heatup. For the NPM loss-of-coolant accident evaluation model core coverage and a minimum critical heat flux ratio are significantly greater than the safety limit, which precludes the occurrence of cladding oxidation (see Reference 7.2.1, Section 2.2). The NRELAP5 code and model have been assessed to experimental data to demonstrate the capability to reliably simulate the scenarios of interest. Conservative values for initial conditions and boundary conditions ensure an overall conservative analysis result.
2.1.2 Regulatory Guide 1.203 Regulatory Guide 1.203, Transient and Accident Analysis Methods (Ref: 7.1.3),
describes a process that the NRC staff considers acceptable for industry use to develop and assess evaluation models used to analyze transient and accident behavior that is within the design basis of a nuclear power plant. An evaluation model is the calculational framework for evaluating the behavior of the reactor system during a postulated transient or design basis accident.
The containment response analysis methodology is an extension of the NuScale LOCA and non-LOCA methodologies developed following the guidance of Regulatory Guide 1.203. This report references the LOCA and non-LOCA methodologies and identifies and justifies the differences in the containment response methodology when compared to those methodologies.
© Copyright 2018 by NuScale Power, LLC 7
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 2.1.3 Design Specific Review Standard for NuScale Small Modular Reactor Design The NRC has issued Design-Specific Review Standard for NuScale SMR Design to guide the NRC staff review of the NuScale FSAR. This document replaces NUREG-0800, Standard Review Plan. The NRC staff has specified the DSRS as an acceptable method for evaluating whether an application complies with NRC regulations for NuScale small modular reactor (SMR) applications, provided that the application does not deviate significantly from the design and siting assumptions made by the NRC staff while preparing the DSRS. The DSRS is used by NuScale as a guide to ensure that the containment response analysis methodology addresses all of the elements that NRC has included. Sections 2.2.3.1 through 2.2.3.4 describe how the containment response analysis methodology is consistent with the applicable DSRS guidelines, justify differences, or indicate non-applicability.
2.1.3.1 Design Specific Review Standard 6.2.1 Containment Functional Design The DSRS Section 6.2.1, Containment Functional Design (Ref: 7.1.4), includes a high-level summary of an acceptable approach and content for a containment response analysis methodology, and references the lower-tier subsections with additional detail about the approach and contents. The comparison of the containment response analysis methodology to applicable content in DSRS Section 6.2.1 is provided in Table 2-1:
Table 2-1 Compliance with Design Specific Review Standard Section 6.2.1 DSRS Section 6.2.1, p. 1 Containment Response Analysis Methodology The containment structure must be The containment response analysis capable of withstanding, without loss of methodology addresses LOCAs function, the pressure and temperature resulting from postulated limiting conditions resulting from postulated loss- breaks, valve-opening events, main of-coolant (LOCA), steam line, or steam line break (MSLB) accidents, feedwater line break accidents. and feedwater line break (FWLB) accidents. A conservative approach to modeling the full spectrum of break and valve sizes and locations is included.
The limiting results are less than the CNV design pressure and temperature.
The containment design basis includes The containment response analysis the effects of stored energy in the reactor methodology includes all primary coolant system, decay energy, and energy system and secondary energy sources from other sources such as the secondary that contribute to the M&E release.
system, and metal-water reactions The energy from the post-LOCA including the recombination of hydrogen oxidation of the cladding that is typical and oxygen. of light water reactors is not applicable to the NuScale design and is not included as discussed by Section 2.1.1.
© Copyright 2018 by NuScale Power, LLC 8
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 The subsequent thermodynamic effects in The containment response analysis the containment resulting from the release methodology uses the NRELAP5 of the coolant mass and energy are system thermal-hydraulic analysis determined from a solution of the code. NRELAP5 solves the time-incremental space and time-dependent dependent conservation equations for energy, mass, and momentum mass, momentum, and energy.
conservation equations.
DSRS Section 6.2.1, p. 2 Containment Response Analysis Methodology GDC 50, among other things, requires that The containment response analysis consideration be given to the potential methodology models engineered safety consequences of degraded engineered features including NPM containment safety features, such as the containment heat removal and the ECCS with heat removal system and the ECCS, the conservative assumptions. Postulated limitations in defining accident single failures are considered. Initial phenomena, and the conservatism of and boundary conditions are selected calculation models and input parameters to maximize containment pressure and in assessing containment design margins. temperature response. Margin is maintained between the analysis results and the CNV design pressure and temperature limits (See Section 5.2.2).
The regulation in 10 CFR 50 Appendix The containment response analysis K.I.A provides the sources of energy that methodology includes all of the sources are required and acceptable to be of energy required in Appendix K.I.A included in determining the mass and with the following exceptions to Items 4 energy release from loss-of-coolant and 5: 4) Fission Product Decay: The accidents and secondary systems pipe American Nuclear Society (ANS)-5.1-ruptures. 1979 decay heat standard with a two-sigma uncertainty is used rather than 120 percent of the 1971 American Nuclear Society (ANS) standard.
Consistent with DSRS 6.2.1.3,Section II, Acceptance Criterion 1.C.v, the ANS-5.1-1979 standard is equal to the decay heat model given in Standard Review Plan (SRP) Section 9.2.5.
- 5) Metal-Water Reaction: The energy from the post-LOCA oxidation of the cladding that is typical of light water reactors is not applicable to the NuScale design and is not included as discussed in Section 2.1.1.
DSRS Section 6.2.1, p. 4 Containment Response Analysis Methodology The temperature and pressure profiles Methodology for simulation of the M&E provided in the applicants technical release and CNV response that is used submittal for the spectrum of LOCA and for establishing the equipment main steam line break accidents are qualification pressure and temperature acceptable for use in equipment envelopes, and to demonstrate the qualification (i.e., there is reasonable long-term cooling capabilities of the assurance that the actual temperatures NPM, are outside of the scope of this and pressures for the postulated accidents report.
© Copyright 2018 by NuScale Power, LLC 9
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 will not exceed these profiles anywhere within the specified environmental zones, except in the break zone).
2.1.3.2 Design Specific Review Standard 6.2.1.1.A Containment The DSRS Section 6.2.1.1.A, Containment (Ref: 7.1.5), includes content related to containment design, including some elements that are associated with the capability to withstand M&E releases. The comparison of the containment response analysis methodology to applicable content in DSRS Section 6.2.1.1.A is provided in Table 2-2:
Table 2-2 Compliance with Design Specific Review Standard Section 6.2.1.1.A DSRS Section 6.2.1.1.A, p. 1 Containment Response Analysis Methodology The temperature and pressure The containment response analysis conditions in the containment due to a methodology includes the spectrum of spectrum (including break size and primary release events resulting from location) of postulated loss-of-coolant postulated limiting breaks (LOCAs) and accidents (LOCAs) (i.e., reactor coolant valve openings, MSLB accidents, and system pipe breaks) and secondary FWLB accidents. The limiting results are system steam and feedwater line breaks less than the CNV design pressure and temperature.
The effectiveness of static (passive) and The containment response analysis active heat removal mechanisms. methodology includes conservative modeling of passive heat removal systems (there are no active heat removal systems in the NuScale design).
Specifically, conservatisms are employed in conservative assumed initial and boundary conditions, including the reactor pool to ensure a bounding peak CNV peak pressure and temperature following events involving release of mass and energy into the CNV. The performance of these systems is shown to be effective in limiting the CNV pressure and temperature response to within acceptable design limits.
Conservatism in initial and boundary conditions is discussed in Section 3.5 DSRS Section 6.2.1.1.A, p. 4 Containment Response Analysis Methodology To satisfy the requirements of GDC 16 For the NuScale FSAR submittal, the and 50 regarding sufficient design results of the containment response margin, for plants in the design stage analysis methodology for the limiting (i.e., at the construction permit (CP) or event scenarios are less than the CNV design certification (DC) stage) of review, design pressure and temperature. The the containment design pressure should containment design pressure provides provide at least a 10% margin above the approximately 8 percent margin to the accepted peak calculated containment limiting LOCA peak CNV pressure. The pressure following a LOCA, or a steam LOCA peak pressure bounds the steam
© Copyright 2018 by NuScale Power, LLC 10
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 or feedwater line break. Design margins or FWLB peak pressures. Additionally, of less than 10% may be sufficient, the overall peakThe overall limiting peak provided appropriate justification is CNV accident pressure resulting from an provided. For plants at the operating inadvertent reactor recirculation valve license (OL) or COL stage of review, the (RRV) opening event is approximately peak calculated containment pressure 986 psia, which is approximately 58 following a LOCA, or a steam or percent below the CNVcontainment feedwater line break, should be less than design pressure. of 1075 psia. It results the containment design pressure. from an inadvertent reactor recirculation valve opening anticipated operational occurrence with a loss of normal AC and DC power.
Additional margin is provided by the NPM design to satisfy the requirements of GDC 16 and 50 as discussed in Section 5.4.
To satisfy the requirements of GDC 38 to The containment response analysis rapidly reduce the containment pressure, methodology is applicable to the initial the containment pressure should be CNV response and demonstrates that reduced to less than 50% of the peak the peak pressure and temperature are calculated pressure for the design basis within the CNV design limits. The LOCA within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after the methodology also demonstrates that the postulated accident. If analysis shows CNV pressure decreases to less than 50 that the calculated containment pressure percent of the peak pressure within 24 may not be reduced to 50% of the peak hours to satisfy the requirements of calculated pressure within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, the Principal Design Criterion 38 for rapid organization responsible for DSRS reduction of containment pressure.
Section 15.0.3 should be notified. Figure 5-29 demonstrates that the CNV pressure for the limiting case is reduced to less than 50 percent of its peak value in less than two hours. This demonstrates the CNV heat removal capability.
DSRS Section 6.2.1.1.A, p. 5 Containment Response Analysis Methodology To satisfy the requirements of GDC 38 The containment response analysis and 50 with respect to the containment methodology models engineered safety heat removal capability and design features involving the containment heat margin, the LOCA analysis should be removal function and the ECCS.
based on the assumption of loss of Conservative assumptions regarding offsite power and the most severe single safety feature performance, in failure in the emergency power system conjunction with conservative initial and (e.g., a diesel generator failure), the boundary conditions, ensure that the containment heat removal systems (e.g., CNV peak pressure and temperature a fan, pump, or valve failure), or the core analysis results following a primary cooling systems (e.g., a pump or valve system release are bounding (See failure). The selection made should result Section 5.4). A limiting single failure is in the highest calculated containment considered (See Section 5.1.1).
pressure Sensitivity cases considering the availability of power are performed to ensure that assumptions associated with availability of these systems ensure
© Copyright 2018 by NuScale Power, LLC 11
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 limiting peak pressure and temperature results (see Section 3.5.2). There are no emergency diesel generators associated with the NPM design. Margin is maintained between the analysis results and the CNV design pressure and temperature limits for the limiting cases.
- 4. To satisfy the requirements of GDC 38 The containment response analysis and 50 with respect to the containment methodology models engineered safety heat removal capability and design features including NPM containment margin, the containment response heat removal and the ECCS with analysis for postulated secondary conservative assumptions that maximize system pipe ruptures should be based containment pressure and temperature on the most severe single failure of the following a secondary system pipe secondary system isolation provisions rupture. For postulated secondary (e.g., main steam isolation valve failure system pipe ruptures, a limiting single or feedwater line isolation valve failure). failure is considered, including main The analysis should also be based on a steam isolation valve or feedwater spectrum of pipe break sizes and reactor isolation valve (FWIV) failure. For the power levels. The accident conditions NuScale design, full power and the selected should result in the highest maximum break size at each break calculated containment pressure or location are the limiting conditions. Initial temperature depending on the purpose and boundary conditions are selected to of the analysis. Acceptable methods for maximize containment pressure and the calculation of the containment temperature response (See Section 3.4).
environmental response to main steam Margin is maintained between the line break accidents are found in analysis results and the CNV design NUREG-0588, Interim Staff Position on pressure and temperature limits. The Environmental Qualification of Safety- longer-term response for equipment Related Electrical Equipment. qualification is not in the scope of this report.
2.1.3.3 Design Specific Review Standard 6.2.1.3 Mass and Energy Release Analysis for Postulated Loss-of-Coolant Accidents The DSRS Section 6.2.1.3, Mass and Energy Release Analysis for Postulated Loss-of-Coolant Accidents (LOCAs) (Ref: 7.1.6), includes the details of an acceptable approach and content for an M&E methodology for LOCAs. As noted, a comparison of NPM design reveals that some of the DSRS content is based on pressurized water reactor (PWR) large-break LOCA phenomena that are not applicable to the NuScale design. The comparison of the M&E methodology to applicable content in DSRS Section 6.2.1.3 is provided in Table 2-3:
© Copyright 2018 by NuScale Power, LLC 12
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 2-3 Compliance with Design Specific Review Standard Section 6.2.1.3 DSRS Section 6.2.1.3, p. 3 Containment Response Analysis Methodology A. Sources of Energy.
The sources of stored and generated The containment response analysis energy that should be considered in methodology includes reactor power; analyses of LOCAs include: reactor decay heat; stored energy in the core; power; decay heat; stored energy in the stored energy in the reactor coolant core; stored energy in the reactor coolant system (RCS) metal, including the system (RCS) metal, including the reactor vessel and reactor vessel reactor vessel and reactor vessel internals; and stored energy in the internals; metal-water reaction energy; secondary system, including the SG and stored energy in the secondary tubing and secondary water. Metal-water system, including the steam generator reaction energy is not included in the tubing and secondary water. containment response analysis Calculations of the energy available for methodology as discussed in Section release from the above sources should 2.1.1.
be done in general accordance with the requirements of paragraph I.A. in The containment response analysis Appendix K to 10 CFR Part 50, Sources methodology models available energy of Heat during the LOCA. However, sources in accordance with the additional conservatism should be requirements of 10 CFR Part 50, included to maximize the energy release Appendix K, paragraph I.A, with the to the containment during the blowdown exception of 1) metal-water reaction and subsequent phases of a LOCA. An energy is not included, and 2) the ANS-example of this would be accomplished 5.1-1979 decay heat standard with a by maximizing the sensible heat stored in two-sigma uncertainty is used rather the RCS and steam generator metal and than a factor of 1.2 with the 1971 ANS increasing the RCS and steam generator standard. Consistent with DSRS 6.2.1.3, secondary mass to account for Section II, Acceptance Criterion 1.C.v, uncertainties and thermal expansion. the ANS-5.1-1979 standard is equal to the decay heat model given in SRP The requirements of paragraph I.B in Section 9.2.5.
Appendix K to 10 CFR Part 50, Swelling and Rupture of the Cladding and Fuel The containment response analysis Rod Thermal Parameters, concerning methodology model of initial stored the prediction of fuel clad swelling and energy in the fuel is consistent with rupture should not be considered. This Paragraph I.A.1 of Appendix K to 10 will maximize the energy available for CFR Part 50. Fuel rods are initialized at release from the core. the maximum initial stored energy condition as determined by the fuel performance analysis. The fuel heat capacity values are conservatively increased to 115 percent of their nominal values to maximize fuel stored energy.
The fuel thermal conductivity values are conservatively decreased to 85 percent of their nominal values to maximize fuel stored energy.
The containment response analysis methodology includes conservative
© Copyright 2018 by NuScale Power, LLC 13
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 elements that maximize the energy release including sensible heat stored in primary and secondary metal structures, and increasing the RCS mass to account for uncertainties and thermal expansion.
The secondary mass is not a significant contributor and a nominal value is used.
The containment response analysis methodology does not consider the fuel cladding swelling and rupture prediction requirements of paragraph I.B in Appendix K to 10 CFR Part 50.
Calculated cladding temperatures for design basis LOCAs are below the threshold for cladding swelling and rupture.
DSRS Section 6.2.1.3, p. 4 Containment Response Analysis Methodology B. Break Size and Location The containment response analysis
- i. The staffs review of the applicant's methodology includes consideration of a choice of break locations and types is spectrum of break types discussed by discussed in SRP Section 3.6.2. Section 3.2.4.1. Break locations are ii. Of several breaks postulated, the chosen such that M&E releases to break selected as the reference case containment are maximized.
should yield the highest mass and ((
energy release rates, consistent with the criteria for establishing the break location and area.
iii. Containment design basis calculations should be performed for a spectrum of possible pipe break sizes and locations to assure that the worst case has been identified.2(a),(c) C. Calculations In general, calculations of the mass and The containment response analysis energy release rates for a LOCA should methodology focuses on determining the be performed in a manner that maximum post-accident containment conservatively establishes the pressure and temperature. The containment internal design pressure methodology employs conservative (i.e., maximizes the post-accident elements to ensure an overall containment pressure response). The conservative result. criteria given below for each phase of the © Copyright 2018 by NuScale Power, LLC 14
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 accident indicate the conservatism that should exist.
- i. Containment Analysis The analytical approach used to compute The M&E release determined by the the mass and energy release profile will containment response analysis be accepted if both the computer methodology is based on the NRELAP5 program and volume noding of the computer code, and the modeling reactor, piping and containment systems approach is similar to the NuScale LOCA are similar to those of an approved evaluation model, Reference 7.2.1 that ECCS analysis. The computer programs complies with the applicable portions of that are currently acceptable include 10 CFR 50 Appendix K. Specific CRAFT-2, and RELAP5, when a flow changes to the LOCA evaluation model multiplier of 1.0 is used with the required to convert it to a conservative applicable choked flow correlation. An methodology to model primary system alternate approach, which is also mass release events are described in acceptable, is to assume a constant Section 3.2.4.1. The Moody critical flow blowdown profile using the initial model with a discharge coefficient of 1.0 conditions with an acceptable choked is used for saturated two-phase critical flow correlation. flow.
ii. Initial Blowdown Phase Containment Design Basis The initial mass of water in the reactor The containment response analysis coolant system should be based on the methodology assumes an initial power RCS volume calculated for the level of 1.02 times the rated power level. temperature and pressure conditions Initial RCS volume and mass are assuming that the reactor has been consistent with that power level. The operating continuously at a power level initial RCS volume conservatively at least 1.02 times the licensed power includes an allowance for RCS thermal level (to allow for instrumentation error). expansion. An assumed power level lower than the level specified (but not less than the licensed power level) may be used The containment response analysis provided the proposed alternative value methodology uses the conservative has been demonstrated to account for Moody critical flow model for two-phase uncertainties due to power level saturated fluid conditions consistent with instrumentation error. Appendix K. For subcooled fluid conditions the (( Mass release rates should be calculated }}2(a),(c) using a model that has been Reference 7.2.1, Sections 8.2.2 and demonstrated to be conservative by 8.2.3 demonstrates the adequacy of the comparison to experimental data. LOCA evaluation model two-phase and single-phase choked and un-choked flow Calculations of heat transfer from models for predictions of M&E release surfaces exposed to the primary coolant based on assessments of comparisons should be based on nucleate boiling heat of NRELAP5 mass flow predictions to transfer. For surfaces exposed to steam, experimental data. heat transfer calculations should be based on forced convection. The containment response analysis methodology uses the heat transfer Calculations of heat transfer from the correlation package in the NRELAP5 secondary coolant to the steam computer code. The LOCA evaluation generator tubes should be based on model report demonstrates these © Copyright 2018 by NuScale Power, LLC 15
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 natural convection heat transfer for tube correlations are applicable to the NPM surfaces immersed in water and design (Ref: 7.2.1). The local fluid condensing heat transfer for the tube conditions and the local heat structure surfaces exposed to steam. surface temperatures determine the heat transfer mode. Nucleate boiling and Calculations of heat transfer to the forced convection are included in the containment wall from released reactor code and are selected if the local steam should be such that the heat conditions are appropriate. removal from containment is conservatively underestimated so that The containment response analysis the containment pressure is maximized. methodology uses the heat transfer In regions where steam jetting occurs, correlation package in the NRELAP5 heat transfer correlations that are based computer code. The LOCA evaluation on jetting of coolant (e.g. based on model report demonstrates these forced convection) may be used as correlations are applicable to the NPM appropriate. Correlations should be design (Ref: 7.2.1). The local fluid appropriately conservative in regions conditions and the local heat structure away from jetting phenomena (e.g. surface temperatures determine the heat based on natural convection, as transfer mode. Forced convection, appropriate). All heat transfer correlations natural convection, condensation, used should be justified. conduction, and nucleate boiling are included in the code and are selected if Calculations of heat transferred from the local conditions are appropriate. condensed reactor water in the Initial and boundary conditions are containment sump into the containment selected to maximize containment wall and from the reactor vessel wall into pressure and temperature response the pooled sump water should be based (See Section 3.5). Steam jetting effects on appropriate heat transfer regimes for are not modeled. the conditions present in containment. Heat transfer through the containment vessel wall into the Reactor Building pool should be demonstrated to conservatively underestimate heat transfer to the pool. DSRS Section 6.2.1.3, p. 5 Containment Response Analysis Methodology iii. Postblowdown Recirculation Phase The containment response analysis (Cold Leg RRV Penetration Breaks Only) methodology uses the NRELAP5 code After initial blowdown through a failed that has been determined to be capable RRV, which includes the period from the of modeling all of the phases of the accident initiation (when the reactor is in primary system release events for the a steady-state full power operation NPM design as discussed by Section condition) to the time that the RCS 3.2. NRELAP5 predicts the evolution of equalizes to the containment pressure, the primary system release event the water remaining in the reactor vessel scenario, which includes the time of should be assumed to be saturated. pressure equalization and the time at Justification should be provided for the which flow of condensed water through duration of the recirculation period, which the RRVs into the reactor vessel occurs. is the time from the end of the blowdown As discussed in Section 3.1.3, the to the time when flow from the containment response analysis condensed water in the containment methodology models applicable vessel sump comes back through the phenomena that contribute to RRVs into the reactor vessel. maximizing the M&E release and the © Copyright 2018 by NuScale Power, LLC 16
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 resulting containment pressure and temperature. Calculations of the refill rate should be based on the ECCS operating condition following the blowdown phase, where The refill rate is only applicable to large energy is released to the RCS primary PWRs. As discussed by the LOCA system by the RCS metal, core decay evaluation model report, the NPM design heat, and the steam generators. The precludes core uncovery (See calculated ECCS conditions should Reference 7.2.1). conservatively maximize the containment As discussed by Section 3.2.4.1, the pressure. containment response analysis methodology models applicable phenomena that contribute to Calculations of liquid entrainment, (i.e., maximizing the M&E release and the the carryout rate fraction), which is the resulting containment pressure and mass ratio of liquid exiting the core to the temperature. liquid entering the core, should be based on the NuScale full length emergency cooling heat transfer experiments or The concept of carryout rate fraction that conservatively scaled-up test results from is applicable to large PWRs is not subscale test. applicable to the NuScale design. As discussed by the LOCA evaluation model report, the NPM design precludes The assumption of steam quenching core uncovery, so there is no reflooding should be justified by comparison with phase (See Reference 7.2.1). applicable experimental data. Liquid As discussed by Section 3.2.4.1, the entrainment calculations should consider containment response analysis the effect on the carryout rate fraction of methodology models applicable the increased core inlet water phenomena that contribute to temperature caused by steam quenching maximizing the M&E release and the assumed to occur from mixing with the resulting containment pressure and ECCS water. temperature. Steam leaving the steam generators The concept of steam quenching (that should be assumed to be superheated to occurs from mixing with ECCS water) the temperature of the secondary that is applicable to large PWRs is not coolant. applicable to the NuScale design because ECCS water is not injected into the core. As discussed by Section 3.2.4.1, the containment response analysis methodology models applicable phenomena that contribute to maximizing the M&E release and the resulting containment pressure and temperature. The superheating effect described is a pressurized water reactor LOCA phenomenon that has minimal © Copyright 2018 by NuScale Power, LLC 17
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 applicability to the NuScale design. For the NPM design, flow of primary steam over the SG tubes results in heat transfer based on the NRELAP5 heat transfer correlation package. This allows for superheating of the steam as determined by the local conditions. DSRS Section 6.2.1.3, p. 6 Containment Response Analysis Methodology iv. Post-Recirculation Phase All remaining stored energy in the The stored energy is distributed as primary and secondary systems should predicted by the NRELAP5 modeling of be removed during the post-recirculation heat transfer to and from the primary phase. and secondary systems. The duration of Steam quenching on the containment the analysis is consistent with the LOCA vessel walls, due to pressure evaluation model and the applicable equalization between the reactor vessel figures-of-merit (See Reference 7.2.1). and the containment vessel, should be The containment response analysis justified by comparison with applicable methodology considers steam experimental data. condensation on the CNV walls, as The results of post-recirculation discussed by Section 3.2.4.1. The analytical models should be compared to NRELAP5 code and model have been applicable experimental data. justified by comparison to applicable experimental data.
- v. Decay Heat Phase The dissipation of core decay heat The containment response analysis should be considered during this phase methodology models the fission product of the accident. The fission product decay energy using the ANS-5.1-1979 decay energy model is acceptable if it is standard plus two-sigma uncertainty.
equal to or more conservative than the SRP Section 9.2.5 references the same decay energy model given in SRP ANS-5.1-1979 standard. Section 9.2.5. The described steam and water mixing Steam from decay heat boiling in the process does not occur in the NPM core should be assumed to flow to the design. Water flowing through the RRVs containment by the path which produces to the core inlet is below the water the minimum amount of mixing with the mixture level in the downcomer and condensed water flowing from the does not contact the steam produced by containment sump into the reactor vessel decay heat boiling. through the RRVs. 2.1.3.4 Design Specific Review Standard 6.2.1.4 Mass and Energy Release Analysis for Postulated Secondary Pipe Ruptures The DSRS Section 6.2.1.4, Mass and Energy Release Analysis for Postulated Secondary Pipe Ruptures (Ref: 7.2.2), includes the details of an acceptable approach and content for a M&E methodology for MSLBs and FWLBs. The comparison of the M&E methodology to applicable content in DSRS Section 6.2.1.4 is provided in Table 2-4: © Copyright 2018 by NuScale Power, LLC 18
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 2-4 Compliance with Design Specific Review Standard Section 6.2.1.4 DSRS Section 6.2.1.4, p. 4 Containment Response Analysis Methodology
- 1. Sources of Energy.
The sources of energy that should be As discussed in Section 3.3, the containment considered in the analyses of steam and response analysis methodology includes all of the feedwater line break accidents include the sources of energy stored in the fluid and stored energy in the affected helical coil structures that contribute to the secondary line SGs metal, including the vessel tubing, break scenarios. This includes energy stored in feedwater line, and steam line; stored fluid contained in piping systems connected to the energy in the water contained within the break flowpath into the CNV. affected helical coil SG; stored energy in the feedwater transferred to the affected The containment response analysis methodology helical coil SG before closure of the considers a spectrum of pipe break sizes and isolation valves in the feedwater line; various plant conditions. However, the limiting stored energy in the steam from the initial conditions are at 102 percent rated power unaffected helical coil SG before the as the effect of SG liquid mass inventory and closure of the isolation valves in the feedwater flows is greatest at full power. (( helical coil SG crossover lines; and energy transferred from the primary coolant to the water in the affected helical coil SG during blowdown to include energy transferred to the draining DHRS heat exchanger water. The steam line break accident should be analyzed for a spectrum of pipe break sizes and various plant conditions from hot standby to 102 percent of full power. }}2(a),(c) The applicant need only analyze the 102-percent power condition if it can demonstrate that the feedwater flows and fluid inventory are greatest at full power.
- 2. Mass and Energy Release Rate In general, calculations of the mass and The containment response analysis methodology energy release rates during a steam or maximizes the CNV peak pressure and feedwater line break accident should be temperature. The Moody critical flow model with a performed in a conservative manner from discharge coefficient of 1.0 is used for saturated a containment response standpoint (i.e., two-phase fluid conditions. For subcooled and the postaccident containment pressure superheated fluid conditions the ((
and temperature are maximized). The }}2(a),(c) A discharge following criteria indicate the degree of coefficient of 1.0 is used. conservatism that is desired: A. Mass release rates should be calculated using the Moody model (Ref. 6) for saturated conditions or a model that is demonstrated to be equally conservative. B. Calculations of heat transfer to the The containment response analysis methodology water in the affected helical coil SG uses the heat transfer correlation package in the should be based on nucleate boiling heat NRELAP5 computer code. The non-LOCA transfer. evaluation model report demonstrates these correlations are applicable to the NPM design (Ref: 7.2.2). The local fluid conditions and the local heat structure surface temperatures © Copyright 2018 by NuScale Power, LLC 19
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 determine the heat transfer mode. Nucleate boiling heat transfer is included in the code and is selected if the local conditions are appropriate. For the helical coil SG, other heat transfer modes exist as the coolant enters as subcooled liquid and exits as superheated steam. Initial and boundary conditions are selected to maximize containment pressure and temperature response (See Section 3.5). C. Calculations of mass release should The containment response analysis methodology consider the water in the affected helical includes the water inventory stored in piping coil SG and feedwater line, feedwater systems connected to the break flowpath into the transferred to the affected helical coil SG CNV. The closure of isolation valves, with before the closure of the isolation valves consideration of a single failure, determines which in the feedwater lines and upon flooding sources of water contribute to the M&E release to with the DHRS heat exchanger inventory ensure limiting CNV peak pressure and in the affected loop, and steam in the temperature results. helical coil SG. D. If liquid entrainment is assumed in the The containment response analysis methodology steam line breaks, experimental data uses the two-phase flow and heat transfer models should support the predictions of the liquid in the NRELAP5 code. The depressurization of entrainment model. A spectrum of steam the SG secondary will cause flashing in addition line breaks should be analyzed, beginning to the increase in primary-to-secondary heat with the double-ended break (DEB) and transfer. The initial liquid inventory in the SG decreasing in area until no entrainment is secondary will boil and flash, and additional calculated to occur. This will allow inventory will result from continued feedwater flow selection of the maximum release case. and from liquid in connecting pipes. The net effect If no liquid entrainment is assumed, a may include some liquid entrainment in the break spectrum of the steam line breaks should flow that is time dependent. An interfacial drag be analyzed beginning with the DEB and multiplier is available as a junction component decreasing in area until it has been option in NRELAP5 to minimize liquid demonstrated that the maximum release entrainment. rate has been considered E. Feedwater flow to the affected helical The containment response analysis methodology coil SG should be calculated considering includes the water inventory stored in in piping the diversion of flow from the other helical systems connected to the break flowpath into the coil SG between the two feedwater pipes CNV. The increase in feedwater flow due to the to the common header with inlets to the depressurization of the helical coil SG is helical coil SG on opposite sides of the considered. The closure of isolation valves with reactor vessel, feedwater flashing, and consideration of a single failure determines which increased feedwater pump flow caused by sources of water contribute to the M&E release. the reduction in helical coil SG pressure. The net feedwater addition is calculated using An acceptable method for computing conservative modeling assumptions. feedwater flow is to assume all feedwater travels to the helical coil SG at the pump run-out rate before isolation. After isolation, the unisolated feedwater mass should be added to the available inventory in the helical coil SG. DSRS Section 6.2.1.4, p. 5 Containment Response Analysis Methodology © Copyright 2018 by NuScale Power, LLC 20
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 iii. Single-Failure Analyses Steam and feedwater line break analyses The containment response analysis methodology should assume a single active failure in considers single failures that affect the isolation of the steam or feedwater line isolation the main steam lines and feedwater lines. Non-provisions to maximize the containment safety valves are credited for isolation as a peak pressure and temperature. For the backup. assumed failure of a safety-related steam or feedwater line isolation valve, operation of nonsafety-related equipment may be relied upon as a backup to the safety-related equipment. © Copyright 2018 by NuScale Power, LLC 21
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 3.0 Analysis 3.1 Modeling Software The containment response analysis methodology uses the NRELAP5 system thermal-hydraulic code, which is a NuScale-modified version of the RELAP5-3D© v 4.1.3 code. NRELAP5 is used for all LOCA and non-LOCA transient and accident analyses, including the response of the CNV. The NRELAP5 simulation model used for the containment response analysis methodology is also similar to the NRELAP5 simulation models used for the LOCA and non-LOCA methodologies, which are presented in References 7.2.1 and 7.2.2. The phenomena identification and ranking tables (PIRT) developed for the LOCA and non-LOCA methodologies are applicable to the containment response analysis methodology. The qualification of the LOCA and non-LOCA methodologies, in particular the comparisons to separate effects tests and integral effects tests, applicable to the containment response analysis methodology are presented in Section 4.1. The differences in the NRELAP5 simulation models used in the containment response analysis methodology as compared to the LOCA and non-LOCA models, along with the rationale for selection of conservative initial and boundary conditions, are the subject of this report. 3.2 NRELAP5 Base Simulation Model Development 3.2.1 RELAP5-3D© RELAP5-3D©, version 4.1.3 was used as the baseline development platform for the NRELAP5 code. RELAP5-3D© was procured by NuScale and subsequently features were added to address unique aspects of the NuScale design and licensing methodology. The following is a brief description of the RELAP5-3D© code. The RELAP5-3D© code has been developed for best-estimate transient simulation of light water RCSs during postulated accidents. The code models the coupled behavior of the RCS and the core for LOCAs and operational transients such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. The RELAP5-3D© code is based on a non-homogeneous and non-equilibrium model for the two-phase system that is solved by a fast, partially implicit numerical scheme to permit economical calculation of system transients. The code includes many generic component models from which general systems can be simulated. The component models include pumps, valves, pipes, heat releasing or absorbing structures, reactor kinetics, electric heaters, and control system components. In addition, special process models are included for effects such as form loss, flow at an abrupt area change, branching, choked flow, boron tracking, and noncondensable gas transport. 3.2.2 RELAP5-3D© Quality Assurance NuScale Power procured RELAP5-3D© v.4.1.3 from the Idaho National Laboratory through a commercial-grade dedication process that complies with NQA-1-2008 and NQA-1a- © Copyright 2018 by NuScale Power, LLC 22
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 2009 requirements. The commercial-grade dedication evaluation determined that verification of certain of the critical characteristics required testing. Eleven test cases were identified for verification, figures of merit, and acceptance criteria. Included were models of the NPM along with NuScale proprietary test programs, legacy tests, and special feature tests. These cases constitute the matrix for commercial-grade dedication acceptance testing as discussed by the LOCA evaluation model report (Reference 7.2.1), Section 6.1.2. RELAP5-3D© v.4.1.3 was then placed under the NuScale quality assurance program as NRELAP5 Version 0.0. Subsequent NRELAP5 versions were developed and placed under the NuScale Quality Assurance Program including the technical code revisions listed in Table 3-3 along with code corrections and administrative code revisions. 3.2.2.1 NRELAP5 NRELAP5 is NuScales proprietary system thermal-hydraulic computer code for use in engineering design and analysis. NRELAP5 was developed at NuScale, using RELAP5-3D© v.4.1.3 as the initial baseline. Chapter 6 of the LOCA Evaluation Model (Ref: 7.2.1) is a summary of the RELAP5-3D© code and the revisions incorporated by NuScale to produce the NRELAP5 code used in both the LOCA Evaluation Model and the Non-LOCA Evaluation Model (Ref: 7.2.2). The new models in NRELAP5 are listed in Table 3-3 along with the application in the containment response analysis methodology. Table 3-1 New NRELAP5 models New Model Application in Containment Response Analysis Methodology Condensation heat transfer Used for condensation heat transfer on
* (( the CNV inside diameter and inside the decay heat removal system (DHRS) heat exchanger tubes }}2(a),(c)
Critical flow Used for two-phase saturated critical
- Moody critical flow model for two- flow phase flow conditions Helical coil SG component Used for modeling the helical coil SGs
- Heat transfer correlation
- Friction correlation Pool heat transfer Churchill-Chu is used for modeling the
- Churchill-Chu natural convection CNV outside diameter (OD), the reactor correlation correction to use bulk pressure vessel (RPV) outside fluid properties diameter, and outside the DHRS heat
- Cooper pool boiling correlation exchanger tubes (vertical surfaces
- Rohsenow pool boiling only).
correlation © Copyright 2018 by NuScale Power, LLC 23
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 New Model Application in Containment Response Analysis Methodology Interfacial drag multiplier Used in containment response analysis
- Input multiplier added to allow methodology to evaluate effect of liquid minimizing liquid entrainment in entrainment on break and valve flow break and valve flow Void drift velocity Used for two-phase flow
- Kataoka-Ishii alternative formulation set to default Critical Heat Flux The 2006 Groenveld tables are used in
- Reyes correlation the containment response analysis
- Electric Power Research Institute methodology. CHF does not occur for all correlation with counter current LOCA and non-LOCA scenarios in the flow limitation or Groenveld as containment response analysis interpolation point for zero flow methodology.
- Chang correlation
- 2006 Groenveld tables
- Extended Hench-Levy correlation Dynamic gap conductance Not used in the containment response
- Dynamic gap conductance model analysis methodology with optional pellet axis offset capability Boric acid solubiity Not used in the containment response
- Compare boric acid analysis methodology concentration to solubility limit Decay heat Not used in the containment response
- 1971 ANS Standard including analysis methodology actinides 3.2.3 NRELAP5 Simulation Models This section presents the NRELAP5 simulation models of the NPM that are used for the containment response analysis methodology. The NRELAP5 models developed for the LOCA and non-LOCA evaluation models are used to develop the primary system (LOCA and valve opening events) and secondary system (MSLB and FWLB events) M&E release and containment response models, respectively. Substantive changes to the NRELAP5 LOCA model are limited to those necessary for containment response analysis applications. Other changes are made to the LOCA model that do not significantly impact primary system release event containment analysis results (see Section 3.2.4.1).
Changes to the NRELAP5 non-LOCA model are limited to those necessary for containment response analysis applications. 3.2.3.1 NRELAP5 LOCA Evaluation Model The NRELAP5 loss-of-coolant accident model input file is developed from engineering drawings, calculations, and reference documents. These sources of information provide the numerical information necessary to develop a complete thermal-hydraulic simulation model of the NuScale SMR per the input file specification. The types of required information fall into the following NRELAP5 input categories: © Copyright 2018 by NuScale Power, LLC 24
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10
- Thermal-hydraulic fluid volumes and connecting heat structures reactor vessel primary loop lower plenum core riser pressurizer SG primary side downcomer reactor kinetics reactor vessel secondary system SG secondary main steam piping feedwater piping CNV reactor pool DHRS ECCS Chemical and volume comtrol system (CVCS) piping for RCS injection, discharge and pressurizer spray supply
- Material properties
- Control systems normal control systems pressurizer pressure pressurizer level Tavg steam pressure turbine load reactor protection system engineered safety feature controls The NRELAP5 NuScale Power Module model from which LOCA runs are initiated is described in the LOCA Evaluation Model in detail (Reference 7.2.1, Section 5.3) and is summarized in this report. The objectives of the NRELAP5 loss-of-coolant accident model are to analyze the LOCA break spectrum for the NPM and to demonstrate compliance with 10 CFR 50 Appendix K.
© Copyright 2018 by NuScale Power, LLC 25
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 3-1 is a simplified diagram of the nodalization selected to enable modeling of the phenomena that were determined to be important for the spectrum of LOCA scenarios. The LOCA primary system release scenarios start with the blowdown of the primary inventory through the pipe break into the CNV. The reactor trips on high CNV pressure, which causes a turbine trip along with main steam isolation and feedwater isolation. The primary system depressurizes as the CNV pressurizes, and the coolant inventory accumulates in the CNV. Steam released into the CNV condenses on the CNV inner surface that is cooled by conduction and convection to the reactor pool. When the primary system inventory reaches the low level setpoint, or the CNV level reaches the high level setpoint, and the pressure drop across the ECCS valves is less than the inadvertent actuation block (IAB) release pressure, the ECCS valves open. Opening of the reactor vent valves (RVVs) increases the primary depressurization rate and completes equalization of primary and secondary pressures. Opening of the RRVs establishes a flowpath for the inventory in the CNV to flow by gravity into the RPV for core cooling. The flowpaths through the break plus the RVV, and the flowpath through the RRV provide abundant core cooling that is sufficient to keep the core covered by a two-phase mixture that prevents any heatup of the fuel rod cladding. The NRELAP5 loss-of-coolant accident model includes the following additions to obtain a conservative LOCA analysis that meets the Appendix K requirements:
- conservative initial conditions at 102 percent of rated power level
- with or without loss of normal alternating current (AC) power
- high core power peaking factors
- break junction modeling for the various break locations
- Moody critical flow option
- ANS 1973 decay heat standard with 1.2 factor and actinides
- limiting single failure assumption
- ECCS actuation with conservative performance
- conservative CNV modeling
- conservative reactor pool modeling
- conservative setpoints and actuation delays The LOCA evaluation model nodalization and each of these conservative LOCA modeling elements are evaluated in Section 3.2.4.1 for use in the primary system release event containment response analysis methodology. The adequacy of the NRELAP5 code and the LOCA model for modeling the primary system M&E scenarios is addressed in Sections 4.1 and 4.2.
© Copyright 2018 by NuScale Power, LLC 26
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c)
Figure 3-1 NRELAP5 NuScale Power Module noding diagram © Copyright 2018 by NuScale Power, LLC 27
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 3.2.3.2 NRELAP5 Non-Loss-of-Coolant Accident Evaluation Models The NRELAP5 non-LOCA models are summarized in this section. The objectives of the NRELAP5 non-LOCA models are to analyze the spectrum of non-LOCA transients and accidents for the NuScale SMR, and to demonstrate compliance with the regulatory acceptance criteria. 3.2.3.2.1 Inadvertent Operation of Emergency Core Cooling System The inadvertent operation of ECCS events include the inadvertent opening of an RVV or an RRV. Both events involve an initial primary system M&E release through the inadvertently opened valve into the CNV, and a subsequent actuation of the remaining ECCS valves that results in a second M&E release into the CNV. The FSAR Section 15.6.6 describes the methodology for analyzing these events and is the starting point for developing the valve opening event models in the primary system containment response analysis methodology. 3.2.3.2.2 Secondary System Pipe Breaks The NRELAP5 non-LOCA model is the starting point for developing the MSLB and FWLB models in the containment response analysis methodology. Figure 3-2 shows the non-LOCA NRELAP5 nodalization diagram. © Copyright 2018 by NuScale Power, LLC 28
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c)
Figure 3-2 NRELAP5 nodalization for non-loss-of-coolant accident evaluation model © Copyright 2018 by NuScale Power, LLC 29
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 The FSAR Chapter 15 MSLB and FWLB scenarios start with the blowdown of the secondary inventory through the pipe break and into the CNV. The reactor trips on high CNV pressure or low steam line pressure, and that causes a turbine trip along with main steam isolation and feedwater isolation. One SG depressurizes as the CNV pressurizes, and an equilibrium is approached. The DHRS actuates and transfers decay heat to the reactor pool. Steam released into the CNV condenses on the CNV inner surface that is cooled by conduction and convection to the reactor pool. The safety concern for the FSAR Chapter 15 main steam line break scenario is the module response to the resulting overcooling, and the key boundary condition for the main steam line large-break scenario is the feedwater supplied to the affected SG. A single failure of the FWIV on the affected SG results in a continuation of feedwater flow until a delayed isolation occurs on feedwater regulating valve (FWRV) closure. The MSLB inside containment analysis includes the following modeling considerations:
- break modeling with (( }}2(a),(c)
- reactor trip on high CNV pressurelow steam line pressure
- main steam isolation valves (MSIVs) actuation
- feedwater isolation and regulating valves actuation
- feedwater pump dynamic response
- feedwater pipe inventory flashing
- DHRS actuation
- with or without loss of normal AC and direct current (DC) electrical power
- limiting single failure The differences in the NRELAP5 MSLB modeling for the containment reponse analysis methodology that focus on a conservative analysis of the CNV peak pressure and temperature response are detailed in Section 3.2.4.2.
The safety concern for the FSAR Chapter 15 FWLB scenario is the module response to the overheating caused by a loss of the SG heat sink and the resulting primary system and secondary system pressurization. The key boundary conditions are the DHRS performance, which limits the peak secondary pressure, and the reactor safety valve (RSV) capacity, which limits the peak primary pressure. A single failure of the MSIV on the intact SG results in a small decrease in secondary inventory during the transition to DHRS operation, and a conservative minimum secondary heat sink. The FSAR Chapter 15 FWLB inside containment analysis includes the following modeling considerations:
- break modeling with (( }}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 30
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10
- reactor trip on high CNV pressure
- MSIVs actuation
- FWIVs actuation
- feedwater pump dynamic response
- feedwater pipe inventory flashing
- DHRS actuation
- with or without loss of normal AC and direct current (DC) electrical power
- limiting single failure The differences in the NRELAP5 feedwater line break modeling for the containment reponse analysis methodology that focus on a conservative analysis of the CNV peak pressure and temperature response are detailed in Section 3.4.2. The adequacy of the NRELAP5 code and the non-LOCA models for evaluation of the secondary system release scenarios is addressed in Sections 4.1 and 4.2.
3.2.4 Containment Reponse Analysis Base Model Development 3.2.4.1 NRELAP5 Primary Release Event Analysis Model Overview The NRELAP5 model used to model NPM performance for primary system (LOCA and ECCS valve opening) release event analyses is similar to the model used in the LOCA evaluation model described in Section 3.2.3.1. The NPM geometry inputs and conservative fuel inputs in the containment response analysis model are consistent with those used by the LOCA Evaluation Model. The following substantive differences are related to the objective of determining the maximum containment peak pressure and peak temperature scenarios. This is accomplished by conservatively maximizing the M&E release and minimizing containment heat removal. Figure 3-3 is an illustration of the NPM during power operation that shows the main design features. Figure 3-4 illustrates the ECCS mode of operation and shows the RVVs and RRVs along with the CNV and reactor pool that provide containment heat removal and ultimate heat sink. The nodalization diagram in Figure 3-1 plus the changes described in this section constitute the NRELAP5 model used to simulate primary release scenarios resulting from bounding breaks and valve opening events. The following modification is included in the primary release event containment response analysis model:
* (( }}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 31
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 3-3 NuScale module during power operation Figure 3-4 NuScale module during emergency core cooling system operation © Copyright 2018 by NuScale Power, LLC 32
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 LOCA Pipe Break and Valve Opening Modeling ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 33
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c)
Figure 3-5 NRELAP5 nodalization for reactor coolant system discharge line break loss-of-coolant accident
© Copyright 2018 by NuScale Power, LLC 34
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c)
Figure 3-6 NRELAP5 nodalization for reactor coolant system injection line break loss-of-coolant accident © Copyright 2018 by NuScale Power, LLC 35
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c)
Figure 3-7 NRELAP5 nodalization for pressurizer spray supply line break and RPV high point vent degasification line loss-of-coolant accident © Copyright 2018 by NuScale Power, LLC 36
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Conservative modeling of the LOCA pipe break spectrum and the valve opening events to ensure a bounding M&E release includes the following elements:
- all break locations are considered
- maximum credible break size at each location
- critical flow with discharge coefficient of 1.0
- saturated liquid - Moody critical flow
- subcooled liquid - (( }}2(a),(c)
- modified pressure volume work term
- maximum RRV and RVV flow areas
- liquid entrainment evaluated by use of interfacial drag multiplier in upper riser, riser upper plenum, pressurizer baffle, pressurizer, and downcomer Containment Vessel and Reactor Pool Models The CNV nodalization in the NRELAP5 loss-of-coolant accident and valve opening event containment response analysis model (Figure 3-6, Component 500) is modified compared toconsistent with the LOCA evaluation model. The following substantive changes were made to the LOCA evaluation model to maximize M&E release and consequential containment pressure and temperature.
* (( }}2(a),(c)
In addition to the five substantive modifications described above, the following non-subtantive modifications are to the LOCA evaluation model:
* (( }}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 37
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c)
A sensitivity analysis demonstrates that the above modifications to the LOCA evaluation model have a negligible effect on CNV analysis results. The CNV is maintained at a partial vacuum with an assumed high initial pressure (e.g. 23.0 psia), soand with the maximum total mass of noncondensables that could exist within the CNV during operation (approximately 131 lbm), in order to capture the effects of CNV non-condensable gases. Also, during a LOCA or valve opening event, the maximum total mass of noncondensables that could exist within the RPV during operation are released to the CNV model, in order to capture the effects of RPV non-condensable gases are small but are modeled. Heat transfer to the CNV vessel inside diameter (ID) is initially by radiative heating from the RPV, and that modeling sets the initial CNV wall temperature distribution. The LOCA or valve opening event M&E release into the CNV results in a rapid heating and pressurization of the CNV. The steam is condensed on the CNV inside diameter and the condensate film flows downward and forms a pool in the bottom of the CNV. As the CNV pool level rises boiling occurs on the RPV surface. Heat transfer from the CNV outside diameter to the reactor pool initially maintains the vessel at a low temperature except for the upper section of the vessel that is above the pool surface elevation. Following the LOCA or valve opening event, the condensing of steam and convection from the CNV pool increases the vessel temperature, and heat transfer from the CNV outside diameter to the reactor pool increases. Heat transfer on the CNV outside diameter is by pool convection and pool nucleate boiling, except for the upper section that is not submerged in the reactor pool. The initial CNV wall temperatures above the pool level are maintained at 240 degrees F, which bounds the maximum CNV wall temperature that can exist during normal operation. In the upper section heat transfer is by convectionneglected due to airthe presence of insulation on the CNV upper head (See Figure 3-8). © Copyright 2018 by NuScale Power, LLC 38
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c)
Figure 3-8 NRELAP5 reactor pool model © Copyright 2018 by NuScale Power, LLC 39
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Conservative modeling of the heat transfer to and from the CNV inside diameter, and from the CNV outside diameter to the reactor pool, to ensure a bounding peak CNV pressure and temperature response following a LOCA or valve opening event, includes the following elements:
* (( }}2(a),(c) * (( }}2(a),(c)
Table 3-2 shows the heat transfer correlations and models for all of the processes that could impact the CNV peak pressure and temperature response. These correlations and models, along with their applications, are described in greater detail in the LOCA Evaluation Model Report (Reference 7.2.1). Table 3-2 Containment vessel and reactor pool heat transfer modeling Heat Transfer Process Correlation/Model Radiant heating from RPV outside Radiation enclosure model considered in analysis. diameter to CNV inside diameter This was not included in the model since inclusion of a radiation enclosure model has a negligible impact on CNV peak pressure and temperature results. Convection from RPV outside diameter Vertical Sufaces to CNV pool ((
}}2(a),(c)
Non-Vertical Surfaces ((
}}2(a),(c) 2(a),(c)
Condensation on CNV inside diameter (( }} Interphase heat transfer Default model based on flow regimes Convection from CNV outside diameter Vertical Sufaces to reactor pool ((
}}2(a),(c)
Non-Vertical Surfaces ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 40
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Heat Transfer Process Correlation/Model (( }}2(a),(c) Reactor pool mixing No mixing is modeled Reactor pool cooling to ambient Assumed adiabatic Reactor pool mixing with other modules No mixing with other modules is modeled 3.2.4.2 NRELAP 5 Secondary System Break Analysis Model Overview The NRELAP5 model used for secondary system pipe break analysis in the containment response analysis methodology is similar to the NRELAP5 model used in the non-LOCA accident FSAR Chapter 15 methodology (Section 3.2.3.2). The differences are related to the objective of determining the maximum containment peak pressure and peak temperature scenarios. This is accomplished by conservatively maximizing the M&E release, and minimizing containment heat removal. The following changes were made to the non-LOCA evaluation model to maximize M&E release and consequential containment pressure and temperature.
* (( }}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 41
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 3-3 is an illustration of the NuScale Power Module during power operation that shows the main design features including the DHRS that actuates for secondary line breaks. For some secondary line break scenarios actuation of the DHRS results in a slow cooldown of the primary system and an eventual opening of the ECCS valves and a second M&E release, when a loss of power to the ECCS valve actuator solenoid occurs. Additions and modifications to this model for the secondary system M&E release analysis are the feedwater system model, the pipe break model, the CNV and the reactor pool model. These modifications to the model are described below. Feedwater System Model The feedwater system is an important boundary condition for the secondary system M&E release analyses. The initial secondary inventory in the helical coil SG is small and does not by itself cause a significant CNV pressurization following a secondary line break. The main source of mass is the feedwater system due to an assumed single failure of the FWIV on the affected helical coil SG. Also, the feedwater pump is assumed to respond to the decrease in helical coil SG pressure by a corresponding increase in feedwater flow. Feedwater flow continues to supply the affected helical coil SG until the FWRV automatically closes to back up the FWIV. Secondary Pipe Break Model The secondary pipe break spectrum modeling in the containment response analysis methodology is the same as in the Non-LOCA Methodology, with the limiting break size being the double-ended break. Figure 3-9 shows the NRELAP5 model of the MSLB. The break is modeled by closing the normal flow path (Valve 910) and by opening two break junctions (Valves 911 and 912) that start the break flow to the CNV at the appropriate elevations. Figure 3-10 depicts the NRELAP5 model of the FWLB. The break is modeled by closing the normal flow path (Valve 913) and by opening two break junctions (Valves 914 and 915) that start the break flow to the CNV at the appropriate elevations. Main steam isolation valve closure isolates the unaffected SG from the affected SG. A single failure of one MSIV to close is addressed by automatic closure of the secondary MSIV on each steam line. © Copyright 2018 by NuScale Power, LLC 42
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c)
Figure 3-9 Main steam lIne break model © Copyright 2018 by NuScale Power, LLC 43
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c)
Figure 3-10 Feedwater line break model © Copyright 2018 by NuScale Power, LLC 44
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Conservative modeling of the secondary pipe breaks to ensure a bounding M&E release includes the following elements:
* (( }}2(a),(c)
Containment Vessel and Reactor Pool Models The CNV and reactor pool models for the MSLB and FWLB containment response analysis methodology are the same as the modeling for LOCA. Refer to Section 3.2.4.1. 3.3 Containment Response Analysis Methodology for Primary System Release Events Section 3.3 presents the details of the containment response analysis methodology for primary system releases resulting from primary system breaks and valve opening events. The NRELAP5 computer code described in Section 3.2.2.1 and the LOCA containment response analysis model described in Section 3.2.4.1 are applied using the methodology in this section to meet the NRC regulations and regulatory guidance in Section 2.0. 3.3.1 Primary System Mass and Energy Release Methodology 3.3.1.1 Loss-of-Coolant Accident Scenario Phenomena Identification and Ranking Table Results NuScale has performed and documented a PIRT for the LOCA scenarios resulting from primary system breaks and ECCS valve opening events. Loss-of-Coolant Accident Evaluation Model Report (Reference 7.2.1), Chapter 4.0, summarizes the LOCA phenomena identification and ranking table. The results of the LOCA phenomena identification and ranking table were used in the development of the NRELAP5 code, the NRELAP5 LOCA model, and the LOCA evaluation model. The results of the LOCA scenario PIRT are directly applicable to the primary system M&E release and resultant CNV pressure and temperature response that are the focus of the containment response methodology. The basis for this statement is that CNV pressure and temperature is a figure-of-merit in the LOCA phenomena identification and ranking © Copyright 2018 by NuScale Power, LLC 45
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 table. Therefore, the LOCA scenario PIRT is also considered to be the LOCA containment response analysis methodology PIRT. 3.3.1.2 Module Response The typical response of the NPM to a primary system M&E release is characterized by a simultaneous depressurization of the primary system and pressurization of the CNV. The module response depends on the size of the break or valve opening, the location of the release as that determines if the release is steam or liquid or two-phase, and the timing of the M&E releases. The resulting high containment pressure signal causes an immediate actuation of the following safety features:
- containment isolation, including closure of MSIVs closure of FWIVs closure of backup MSIVs (non-safety) closure of FWRVs (non-safety)
- reactor trip
- turbine trip
- DHRS actuation Any steam that is released through the break or valve condenses on the cold inner surface of the CNV. Condensate and any unflashed break liquid accumulates into a pool on the bottom of the CNV. The primary system level decreases due to the break or valve flow.
The ECCS actuates on the following conditions:
- low RPV level
- high CNV level
- loss of normal AC power and the highly reliable DC power system The following design criteria govern RVVs and RRVs opening:
- If the pressure differential across the valves is greater than the IAB threshold when the ECCS signal actuates, then the valves stay closed until the pressure differential decreases to below the IAB release pressure
- If the pressure differential across the valves has decreased to below the IAB threshold pressure when the ECCS signal actuates, then the valves open and the IAB release pressure is not used Opening of the RVVs increases the depressurization rate, and the primary system and CNV pressures approach equalization. As the pressures equalize, the break/valve flow decreases. With pressure equalization and the increase in the CNV pool level, flow through the RRVs into the reactor vessel starts to provide long-term core cooling via recirculation. This terminates the reactor vessel level decrease prior to core uncovery.
© Copyright 2018 by NuScale Power, LLC 46
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Heat transfer to the CNV wall and to the reactor pool eventually exceeds the energy addition from the break flow and the RVV flow. When this occurs the period of peak containment pressure and temperature have been completed, and a gradual depressurization and cooling phase begins. 3.3.1.3 Event Scenarios and Break Spectrum The postulated primary system M&E release events include the following pipe break accidents and valve actuations. For the valve opening events, the specific FSAR events that result in actuation of that valve are listed.
- Pipe breaks (LOCAs)
FSAR 15.6.5 - RCS discharge line break LOCA (( }}2(a),(c) FSAR 15.6.5 - RCS injection line break LOCA ((
}}2(a),(c)
FSAR 15.6.5 - Pressurizer spray supply line break LOCA (( }}2(a),(c) FSAR 15.6.5 - RPV high point degasification line LOCA (( }}2(a),(c)
- RSV actuation (( }}2(a),(c)
FSAR 15.6.1 - Inadvertent RSV opening
- RVV actuation ((( }}2(a),(c))
FSAR 15.6.6 - Inadvertent RVV opening
- RRV actuation (( }}2(a),(c)
FSAR 15.6.6 - Inadvertent RRV opening The RPV high point degasification line, the pressurizer spray supply line, and the RSVs are all located near the top of the RPV. A LOCA in the RPV high point degasification line is the largest break size in this location and is analyzed in the containment response analysis methodology. The other two are non-limiting and are not analyzed. One RVV or one RRV can open as an initiating event due to an assumed mechanical failure. The RVVs and RRVs all open following ECCS signal actuation and when the IAB design criteria discussed in Section 3.3.1.2 are met . The RPV high point degasification line break LOCA differs in that the break flow will be steam. The RCS break locations differ in that the discharge line connects to the downcomer, and the injection line connects to the riser. These three break locations plus the valve opening event locations fulfill the adequacy of the break spectrum with regard to location. The adequacy of the break spectrum with regard to break size is important in the timing of the ECCS valve opening, as the second M&E release resulting from the opening of the three RVVs is the dominant event for CNV pressure and temperature response. First, the maximum break size at each location is analyzed to ensure the maximum initial M&E release rate into the CNV during the first phase of CNV pressurization. Then, the sensitivity © Copyright 2018 by NuScale Power, LLC 47
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 of the opening time of the three RVVs is addressed by analysis of a range of IAB release pressures for each break location. In this manner a lower IAB release pressure results in a delay in the RVV opening time. This is similar to a break size sensitivity because a range of break sizes would result in a range of depressurization rates and RVV opening times. However, by using the maximum break size for all cases the maximum initial M&E release rate is used for all cases. This approach fulfills the adequacy of the break spectrum with regard to break size. ((
}}2(a),(c)
In summary, the limiting postulated primary system M&E release scenarios consist of an initiating anticipated operational occurrence or accident, which may include a pipe break or RVV or RRV valve opening, with a resultant an ECCS actuation signal causing all RVVs and RRVs to fully open after the IAB design criteria discussed in Section 3.3.1.2 are met. Table 3-3 shows the primary system M&E release scenarios that are used to determine the limiting cases. Table 3-3 Primary system mass and energy release scenarios Iniating Event Subsequent RVV and RRV Analysis Actuations on ECCS Case LOCA in RCS Three RVVs and two RRVs actuate 1 discharge line from downcomer LOCA in RCS Three RVVs and two RRVs actuate 2 injection line from riser LOCA in RPV High Three RVVs and two RRVs actuate 3 Point Degasification Line near top of vessel © Copyright 2018 by NuScale Power, LLC 48
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Iniating Event Subsequent RVV and RRV Analysis Actuations on ECCS Case RVV opens due to a Two RVVs and two RRVs actuate 4 mechanical failure RRV opens due to a Three RVVs and one RRV actuate 5 mechanical failure 3.3.1.4 Identification of Bounding Events The bounding events for peak CNV pressure and for peak CNV temperature are identified by analyzing the spectrum of scenarios in Table 3-3 with conservative initial conditions and boundary conditions. Sensitivity studies are used to determine the bounding conditions and assumptions for the limiting cases. This is further discussed in Section 5.1.1. 3.4 Secondary System Containment Response Analysis Methodology Section 3.4 presents the details of the containment response analysis methodology for the secondary system pipe break accidents. The NRELAP5 computer code described in Section 3.2.2.1 and the secondary system containment response analysis model described in Section 3.2.4.2 are applied using the methodology in this section to meet the NRC regulations and regulatory guidance discussed in Section 2.0. The methodology for the main MSLB and the FWLB accident analyses is presented. 3.4.1 Steamline Break Mass and Energy Release Methodology 3.4.1.1 Non-Loss-of-Coolant Accident Event Phenomena Identification and Ranking Table Results NuScale has performed and documented a PIRT for the non-LOCA events. The results of the non-LOCA phenomena identification and ranking table are summarized in the non-LOCA evaluation model (Ref: 7.2.2). The results of the non-LOCA phenomena identification and ranking table are directly applicable to the secondary system M&E release and CNV pressure and temperature response that are the focus of the containment response analysis methodology. The basis for this statement is that ((
}}2(a),(c) Therefore the non-LOCA phenomena identification and ranking table is also considered to be the secondary system containment response analysis PIRT.
3.4.1.2 Module Response The NPM initially responds to a MSLB inside the CNV with a simultaneous depressurization of the secondary system and a pressurization of the CNV. Feedwater flow out the break increases due to the decrease in backpressure and due to flashing of the feedwater pipe inventory. The resulting high containment pressure signal causes an immediate actuation of the following safety features:
- containment isolation including
© Copyright 2018 by NuScale Power, LLC 49
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 closure of primary main steam isolation valves closure of FWIVs closure of backup main steam isolation valves (non-safety) closure of FWRVs (non-safety)
- reactor trip
- DHRS actuation
- turbine trip As the secondary system depressurizes, the feedwater pump flowrate increases in response to the decrease in SG pressure. Closure of the MSIVs separates the affected SG from the unaffected SG, thereby reducing the mass and energy release. Actuation of the DHRS on the unaffected SG establishes long-term decay heat removal. Closure of the FWIVs terminates the supply of secondary inventory and the affected SG boils dry. The initial primary system transient is a moderate overcooling event that does not result in ECCS actuation. Steam that is released through the break condenses on the cold inner surface of the CNV. Condensate accumulates into a pool on the bottom of the CNV. As the break flow decreases, the CNV pressure and temperature decrease and the time period of the peak values is completed. The peak pressure and temperature are significantly less than for a LOCA due to the smaller secondary inventory that is released prior to feedwater isolation.
The typical MSLB scenario is more severe when a single failure is considered. The limiting single failure is a failure of the FWIV to close on the affected SG. Closure of the FWRV is credited in this scenario, but the much longer stroke time results in a higher CNV peak pressure and temperature. Isolation of the feedwater ends the mass and energy release, and the CNV pressure and temperature then decrease due to heat transfer to the reactor pool through the CNV. When this occurs the period of peak containment pressure and temperature have been completed, and a gradual depressurization and cooling phase begins via the DHRS. The above MSLB scenario is made more adversechanged by assuming a loss of normal AC and DC power (concurrent with the break), which results in an ECCS signal. Subsequent primary system depressurization resulting from heat transfer via the DHRS along with a loss of power to the pressurizer heaters leads to ECCS actuation when the pressure differential decreases to below the IAB release pressure. Opening of the RVVs results in a second M&E release from the primary system, and the peak CNV pressure and temperature from this second release may be higher thanclose to the initial peak from the secondary system M&E release. 3.4.1.3 Limiting Event Description The limiting MSLB event is a double-ended rupture of the largest main steam line (12 in. Schedule 120 / 10.75 in. ID), which is a break area of 0.6303 ft2. Both SGs blow down into the CNV until the MSIVs close. After the initiation of the break there are two potential limiting events depending on the evolution of the scenario with continued normal AC power, or following a loss of normal AC and DC power. © Copyright 2018 by NuScale Power, LLC 50
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 For the scenario with continued normal AC power, the affected SG continues to blow down until feedwater is isolated including a single failure of the FWIV on the affected SG. This results in an extended period of feedwater delivery until the FWRV closes. The availability of power to the pressurizer heaters maintains primary system pressure and there is no ECCS actuation. The peak CNV pressure and temperature occurs as a result of the blowdown of the affected SG, and then the event is terminated. For the scenario with a loss of normal AC and DC power concurrent with the break, the feedwater pump stops and the delivery of feedwater to the affected SG is less than the case with continued normal AC and DC power. The loss of normal AC and DC power causes an ECCS actuation signal and a loss of power to the pressurizer heaters. With DHRS actuation the primary system begins a gradual cooldown and depressurization. The IAB prevents the ECCS valves from opening until the pressure differential decreases to below the IAB release pressure. Opening of the RVVs initiates a primary system M&E release with the CNV pre-heated and pressurized from the initial MSLB M&E release. This second M&E release has the potential to produce the peak CNV pressure and wall temperature results. Continued heat transfer through the CNV wall to the reactor pool results in a gradual cooldown and depressurization. Analysis of the two above scenarios has determined that the case with continued normal AC power results in the peak CNV pressure and peak CNV temperature results. 3.4.2 Feedwater Line Break Mass and Energy Methodology 3.4.2.1 Module Response The NPM initially responds to an FWLB inside the CNV with a reduction in the secondary heat sink due to the loss of feedwater flow, a depressurization of the affected SG as it blows down, and a pressurization of the CNV. Feedwater flow out the break increases due to the decrease in backpressure and due to flashing of the feedwater pipe inventory. The resulting high containment pressure signal causes an immediate actuation of the following safety features:
- containment isolation including closure of primary main steam isolation valves closure of FWIVs closure of backup main steam isolation valves (non-safety) closure of FWRVs (non-safety)
- reactor trip
- DHRS actuation
- turbine trip Closure of the MSIVs separates the affected SG from the unaffected SG, thereby reducing the mass and energy release. Actuation of the DHRS on the unaffected SG establishes long-term decay heat removal. Closure of the FWIVs terminates the supply of feedwater
© Copyright 2018 by NuScale Power, LLC 51
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 to the break, and the affected SG dries out and ends the secondary mass and energy release. The primary system transient is initially a moderate overheating event that is stabilized by DHRS heat transfer, and does not result in ECCS actuation. Any steam that is released through the break condenses on the cold inner surface of the CNV. Condensate accumulates along with unflashed break liquid into a pool on the bottom of the CNV. As the break flow decreases, the CNV pressure and temperature decrease and the time period of the peak values is completed. The typical FWLB scenario is potentially more severe when a single failure is considered. The postulated single failures are a failure of the FWIV to close, or a failure of the MSIV to close, on the affected SG. Closure of the nonsafety-related FWRV, or closure of the non-safety secondary MSIV to close, is credited in this scenario, but the longer stroke times result in a higher CNV peak pressure and temperature. Isolation of the feedwater ends the secondary system mass and energy release, and the CNV pressure and temperature then decrease due to heat transfer to the reactor pool through the CNV and via the DHRS. When this occurs the period of peak containment pressure and temperature have been completed, and a gradual depressurization and cooling phase begins. The above FWLB scenario is made more adverse by assuming a loss of normal AC and DC power concurrent with turbine trip that results in an ECCS actuation signal. The loss of pressurizer heaters causes a gradual primary system depressurization during the DHRS cooldown, and subsequent opening of the RVVs when the pressure differential decreases to the IAB release pressure. Opening of the RVVs initiates a second M&E release. 3.4.2.2 Limiting Event Description For each feedwater train, the FW line geometry inside CNV changes from one 5 Schedule 120 line (between the FWIV and the FW tee) to two 4 Schedule 120 lines (between the FW tee and the FW plenum). The 0.1433 ft2 FW line break area used in the CNV analysis represents the total area of two 4 Schedule 120 lines between the FW tee and the FW plenum. The maximum break area of a single FW line inside CNV is actually 0.1136 ft2, corresponding to one 5 Schedule 120 line between the FWIV and the FW tee. However, since these two geometries are located at the same region (i.e. the FW tee), assuming a larger FW break size (0.1433 ft2) is acceptable since it conservatively maximizes mass release to CNV. The limiting FWLB event is a double-ended rupture of the largest feedwater pipe (5 in. Schedule 120 / 4.563 in. ID), which iswith a break area of 0.14331136 ft2. The affected SG and its feedwater pipe blow down into the CNV. The unaffected SG responds to the depressurization of the affected SG until the MSIV closes. The feedwater piping on the affected SG then continues to blow down until feedwater is isolated by FWIV closure. A single failure of the FWIVMSIV to close on the affected SG is mitigated by closure of the FWRVbackup MSIV. The limiting case also assumes a loss of normal AC and DC power at time of turbine tripevent initiation, and that results in ECCS signal actuation and a loss of power to the pressurizer heaters. With DHRS actuation the primary system begins a gradual cooldown and depressurization. The IAB prevents the ECCS valves from opening until the pressure differential eventually decreases to below the IAB release pressure. © Copyright 2018 by NuScale Power, LLC 52
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Opening of the RVVs combines a subsequent primary system M&E release with the initial feedwater line break M&E release and results in a significantly more severe CNV pressure and temperature response. Analysis of the above scenarios has determined that the case with loss of normal AC and DC power and ECCS actuation results in the peak CNV pressure and peak CNV temperature. A single failure of the FWIV on the affected steam generatior to close, and minimum initial primary system pressure, are included in the limiting case based on sensitivity analysis results. 3.5 Initial and Boundary Conditions 3.5.1 Primary System Release Event Initial Conditions Initial conditions for the spectrum of primary system release containment response analyses are selected to ensure a conservative CNV peak pressure and peak temperature result. The process of selecting the initial conditions is consistent with the guidance in DSRS Section 6.2.1.3. The selection process ensures that energy sources are maximized and energy sinks are minimized. Table 3-4 presents the primary system initial conditions for the primary system release containment response analyses. Table 3-4 Primary system initial conditions Parameter Conservative containment Rationale response analysis methodology Initial Condition ((
}}2(a),(c)
The initial conditions in the secondary system, in particular ((
}}2(a),(c) The SG initial conditions result from the NRELAP5
© Copyright 2018 by NuScale Power, LLC 53
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 initialization process and are consistent with the conservative primary system initial conditions. The initial conditions for the CNV and the reactor pool are shown in Table 3-5. These initial conditions ensure that the CNV heat sink is minimized so that the peak containment pressure and temperature are modeled conservatively. Table 3-5 Containment vessel and reactor pool initial conditions Parameter Initial Condition Assumption Rationale ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 54
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Parameter Initial Condition Assumption Rationale ((
}}2(a),(c) 3.5.2 Primary System Release Event Boundary Conditions Boundary conditions for the spectrum of primary system M&E release analyses are selected to ensure a conservative CNV peak pressure and peak temperature result. The process of selecting the boundary conditions is consistent with the guidance in DSRS Section 6.2.1.3. The selection process ensures that energy sources are maximized and energy sinks are minimized. Due to the simplicity of the NPM design there are few postulated single failures for the primary system M&E release scenarios. Failure of ECCS valves to open would obviously reduce the M&E releaseare analyzed as sensitivity studies, and are not limiting. Failuresfailure of MSIVs or FWIVs to close are analyzed as sensitivity studies,considered, but they have minimal effect on the CNV pressure and temperature response as the secondary system response is not importantis immediately isolated for the primary side events. Table 3-6 presents the boundary conditions for the LOCA containment response analyses.
© Copyright 2018 by NuScale Power, LLC 55
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 3-6 Primary system boundary conditions Parameter Boundary Condition Rationale Assumption ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 56
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Parameter Boundary Condition Rationale Assumption ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 57
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Parameter Boundary Condition Rationale Assumption ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 58
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 3.5.3 Main Steam Line Break Initial Conditions Initial conditions for the MSLB containment response analyses are selected to ensure a conservative CNV peak pressure and peak temperature result. The process of selecting the initial conditions is consistent with the guidance in DSRS Section 6.2.1.4. The selection process ensures that energy sources are maximized and energy sinks are minimized. Table 3-4 presents the primary system initial conditions used for primary system release containment response analyses. ((
}}2(a),(c) Table 3-5 presents the CNV and reactor pool initial conditions used by the LOCA containment response analyses that are also used by the MSLB containment response analyses. Table 3-7 presents the secondary system initial conditions used by the MSLB containment response analyses.
© Copyright 2018 by NuScale Power, LLC 59
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 3-7 Secondary system initial conditions Parameter Initial Condition Rationale Assumption ((
}}2(a),(c) 3.5.4 Main Steam Line Break Boundary Conditions Boundary conditions for the MSLB mass and energy release analyses are selected to ensure a conservative CNV peak pressure and peak temperature result. The process of selecting the boundary conditions is consistent with the guidance in DSRS Section 6.2, and specifically DSRS Section 6.2.1.4. The selection process ensures that energy sources are maximized and energy sinks are minimized.
The largest break size is assumed to maximize the secondary system M&E release rate into the CNV and thereby maximize the resulting CNV pressurization and temperature increase. However, a subsequent primary system M&E release following ECCS actuation and delayed opening of the three RVVs may result in the peak CNV pressure and temperature response for some scenarios. Also, opening of the RVVs depends on the IAB © Copyright 2018 by NuScale Power, LLC 60
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 design criteria in Section 3.3.1.2 being satisfied, and that may not occur until the DHRS has been operating for some period of time. As the DHRS cools the primary system, a delayed M&E release through the RVVs will be smaller, and the second CNV pressurization will be lower. Furthermore, the steam line break CNV pressure and temperature response remains bounded by the LOCA. Therefore, the maximum MSLB size is bounding and a break spectrum analysis is not necessary. Due to the simplicity of the NPM design, there are few postulated single failures for the secondary system M&E release scenarios. Failure of ECCS valves to open would obviously reduceis considered for the M&E release and are not analyzedscenarios in which ECCS actuation occurs. Failures of MSIVs or FWIVs to close are analyzed as sensitivity studies. Table 3-6 presented the boundary conditions for the primary system containment response analysis methodology, and they are the same for the MSLB containment response analysis methodology except for those presented in Table 3-8. Table 3-8 Boundary conditions for the main steam line break containment response analysis methodology Parameter Boundary Condition Rationale Assumption ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 61
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Parameter Boundary Condition Rationale Assumption ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 62
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 3.5.5 Feedwater Line Break Initial Conditions Initial conditions for the FWLB mass and energy release analyses are selected to ensure a conservative CNV peak pressure and peak temperature result. The process of selecting the initial conditions is consistent with the guidance in DSRS Section 6.2, and DSRS Section 6.2.1.4 specifically. The selection process ensures that energy sources are maximized and energy sinks are minimized. Table 3-4 presents the primary system initial conditions used by the LOCA containment response analyses. ((
}}2(a),(c) Table 3-5 presents the CNV and reactor pool initial conditions used by the LOCA containment response analyses, and these initial conditions are also used by the FWLB containment response analyses. Table 3-7 presents the secondary system initial conditions used by the MSLB containment response analyses, and these initial conditions are also used by the FWLB containment response analyses.
3.5.6 Feedwater Line Break Boundary Conditions Boundary conditions for the FWLB mass and energy release analyses are selected to ensure a conservative CNV peak pressure and peak temperature result. The process of selecting the boundary conditions is consistent with the guidance in DSRS Section 6.2, and specifically DSRS Section 6.2.1.4. The selection process ensures that energy sources are maximized and energy sinks are minimized. Section 3.4.4 and Table 3-8 presented the boundary conditions used by the MSLB containment response analyses, these boundary conditions are also used by the FWLB containment response analyses, with the exception of the single failure evaluation that is discussed below. The largest break size is assumed to maximize the initial M&E release into the CNV. However, it is the subsequent second M&E release following ECCS actuation and opening of the three RVVs that results in the peak CNV pressure and temperature response. Also, opening of the RVVs depends on the pressure differential decreasing to below the IAB release pressure, and that may not occur until DHRS has been operating for some period of time. Therefore, the initial break size is unimportant as the secondary M&E release is similar, and the sequence of events leading to the opening of the RVVs is similar. Furthermore, the feedwater line break CNV pressure and temperature response is bounded by the LOCA. Therefore, a break spectrum analysis is not necessary. Due to the simplicity of the NPM design, there are few postulated single failures for the secondary system M&E release scenarios. Failure of ECCS valves to open would obviously reduceis considered for the M&E release and are not analyzed.scenarios in which ECCS actuation occurs. Failures of a MSIV or a FWIV to close are analyzed as sensitivity studies, with the FWIV failure identified as limiting. © Copyright 2018 by NuScale Power, LLC 63
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 4.0 Qualification and Assessment 4.1 Assessment of Methodology and Data 4.1.1 Primary System Release Effects Code and Model Qualification The NRELAP5 code has been qualified or assessed to the separate effects and integral effects tests as described by LOCA Evaluation Model Report (Reference 7.2.1), Chapter 7.0 to demonstrate the capability to simulate LOCAs in the NPM. The results of the NRELAP5 comparisons to data establish the capability of the code to model the NPM design for the LOCA analysis. The most important assessment activities were those comparing to integral LOCA tests conducted in the NIST-1 facility. The following two key known scaling distortions are relevant to the scope of the containment response analysis methodology:
* (( }}2(a),(c)
Neither of the above phenomena have an impact on the peak CNV pressure. The first distortion is addressed by the containment response analysis methodology by closure of the MSIVs. The second distortion is addressed by the overall conservative modeling of CNV heat transfer in the containment response analysis methodology, which includes use of conservative initial conditions and boundary conditions that are discussed in Section 3.4. The LOCA Evaluation Model Report (Reference 7.2.1, Section 8.2) also presents the evaluation of the adequacy of the NRELAP5 code and LOCA Evaluation Model for modeling LOCAs in the NPM. The following action was identified as needed to address adequacy issues relative to the containment response analysis methodology:
* (( }}2(a),(c)
((
}}2(a),(c)
No additional qualification activities were performed for the LOCA containment response analysis methodology as the LOCA evaluation model qualification activities addressed in LOCA Evaluation Model Report (Ref: 7.2.1) are adequate. © Copyright 2018 by NuScale Power, LLC 64
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 4.1.2 Secondary System Pipe Break Effects Code and Model Qualification The LOCA-event code and model qualification as described in Section 4.1.1, which credits the LOCA Evaluation Model qualification activities, is generally applicable to the secondary system M&E release events. Additional NRELAP5 code and model qualification activities were included in the Non-LOCA Evaluation Model (Reference 7.2.2) with the focus being DHRS and SG heat transfer as they are of greater importance during non-LOCA events. The following NIST-1 facility and testing distortions are applicable to secondary M&E release containment analysis methodology:
* (( }}2(a),(c)
The secondary system M&E releases consist of the MSLB and the FWLB events, and both of these events involve asymmetric responses in the two SGs. Following break initiation the affected SG blows down into the CNV until the feedwater supply has been isolated. The unaffected SG is isolated from the affected SG following closure of the MSIVs, and then provides decay heat removal via the DHRS. A second M&E release for these events occurs for cases that include ECCS actuation on loss of normal AC and DC power coincident with the pipe break. The primary pressure gradually decreases during the DHRS cooldown phase, and the ECCS valves open when the differential pressure decreases to below the IAB release pressure. The NRELAP5 code and the containment response analysis model for the NPM are fully capable of modeling the secondary system M&E releases without directly applicable NIST-1 test data. The large body of NIST-1 separate effects and LOCA integral tests have demonstrated the capability of NRELAP5 to adequately model the NPM design. There are no additional phenomena associated with secondary M&E releases, and no additional qualification activities were performed for the secondary containment response analysis methodology. Additional justification for the above position is that the secondary system M&E release analyses for the NPM demonstrate that they are non-limiting compared to the primary system containment response analyses. This justification is further supported by the overall conservatism in the containment response analysis methodology. © Copyright 2018 by NuScale Power, LLC 65
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 4.2 Testing Results 4.2.1 NuScale Integral System Test Facility Testing A scaled facility of the NPM was constructed at Oregon State University, referred to as the NuScale Integral System Test Facility-1, or NIST-1, facility, to assist in validation of the NRELAP5 system thermal-hydraulic code. The facility is designed to perform various tests, including LOCA tests. A detailed description of NIST-1, the NRELAP5 model of the facility, and the NRELAP5 validation testing is provided in Reference 7.2.1, Section 7.5. The NRELAP5 predictions of CNV pressure, level and temperature documented in Reference 7.2.1 show good fidelity to NIST-1 experimental measurements as follows. The CNV level and pressure response is predicted with reasonable to excellent agreement to RCS discharge line break experimental measurements as discussed by Reference 7.2.1, Section 7.5.6. ((
}}2(a),(c)
The CNV pressure response is predicted with reasonable to excellent agreement to spurious RVV opening experimental data as discussed by Reference 7.2.1, Section 7.5.8. A separate high pressure condensation test described by Reference 7.2.1, Section 7.5.4 demonstrates that NRELAP5 has the capability to predict condensation rates for various pressures with reasonable to excellent agreement to experimental data. © Copyright 2018 by NuScale Power, LLC 66
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 5.0 Results 5.1 Primary System Release Scenario Containment Response Analysis This section presents the results of the NRELAP5 limiting analyses of the spectrum of primary system M&E release scenarios for the NPM, listed in Table 3-3, and secondary system break scenarios that are determined using the containment response analysis methodology presented earlier in this report. The case labels from Table 3-3 are used in the following discussion. 5.1.1 Analysis Approach The approach to determine the limiting peak CNV pressure event from the the spectrum of primary mass and energy release scenarios for the NPM, listed in Table 3-3, and the limiting peak CNV temperature for each primary release event was as follows: ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 67
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 ((
}}2(a),(c) 5.1.2 Reference Analysis and Sensitivity Results The following insights were obtained from the results of the NRELAP5 analyses of the five primary system M&E release cases and associated sensitivity studies.
- The peak CNV pressure scenario is the RRV release (Case 5). The RRV mass and energy release causes an initial heatup and pressurization of the CNV, and then ECCS actuation results in a second M&E release with all three RVVs and second RRV opening that pressurizes the CNV to the highest peak pressure.
- The peak CNV wall temperature scenario is the CVCS injection line LOCA (Case 2).
The break in this location combines a high temperature liquid initial M&E release followed by a high temperature M&E release through all three RVVs following an ECCS actuation signal.
- The sensitivity parameters have only a small effect on the peak CNV pressure (~+18 psi / ~+1.9 percent) and temperature (~+5 degrees F / ~+1 percent) results of the limiting cases. No single failures had a significant impact on the results for the limiting cases. The loss of power sensitivity that results in early ECCS actuation, and the IAB release pressure sensitivity that affects the timing of the opening of the ECCS valves, were the more important sensitivity parameters.
* (( }}2(a),(c) 5.1.3 Primary Release Scenario Pressure and Temperature Results The initial conditions used by NRELAP5 analyses for each of the five cases in Table 3-4 are shown in Table 5-1. The initial condition values in the second column of Table 5-1 are the nominal values plus the uncertainty or conservative allowance in parentheses. The assumed parameter values are consistent with the methodology as discussed by Section 3.5.1 and maximize heat sources while minimizing heat sinks. The decay heat conservatively used by these analyses is 120 percent of the 1979 ANS standard rather
© Copyright 2018 by NuScale Power, LLC 68
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 than the methodology assumption (1979 ANS standard plus 2-sigma uncertainty). The 120 percent assumption bounds the required 2-sigma uncertainty required by the containment response analysis methodology (See Table 3-6). Table 5-1 Initial conditions for primary system release event analyses Parameter Conservative Containment Response Analysis Methodology Initial Condition ((
}}2(a),(c)
The results of each of the five primary containment response analysis release analysis cases are summarized in the following sections, with more detailed results and discussion provided for the limiting CNV peak pressure scenario (Case 5 - RRV loss-of-coolant accident), and for the limiting CNV peak temperature scenario (Case 2 - RCS injection line break LOCA). 5.1.3.1 Case 1: Reactor Coolant System Discharge Line Break Loss-of-Coolant Accident The LOCA in the RCS discharge line initiates an M&E release from the downcomer into the CNV. The sequence of events is shown in Table 5-2. The CNV pressure response and temperature response are shown in Figures 5-1 and 5-2. The CNV peak CNV pressure is 884705 psia for the reference case, and 906943 psia with the combined effect of the adverse sensitivity parameters (loss of normal AC and DC power, 1200 psid IAB release pressure)., low-biased High CNV Level setpoint, fine CNV volume nodalization). The peak CNV wall temperature is 499492 degrees F for the reference case, and 502510 degrees F with the combined effect of the adverse sensitivity parameters (loss of normal AC and DC power, 9001200 psid IAB release pressure, highlow-biased High CNV level signal, high primary system flow, RRV single failureLevel setpoint, fine CNV volume nodalization). Case 1 is non-limiting. © Copyright 2018 by NuScale Power, LLC 69
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 5-2 Case 1 sequence of events - reactor coolant system discharge line break loss-of-coolant accident Peak CNV Pressure Case Event Peak CNV Temperature Case Time (sec) Time (sec) LOCA in RCS discharge line For peak pressure case
- Loss of normal AC and DC power
- ECCS actuation signal
- FW/MS isolation
- Reactor trip 500 Same
- Containment isolation
- MSIV closure
- FWIV closure For peak pressure case Loss of normal AC power only for peak temperature case
- Same High CNV pressure resulting in For peak pressure case
- Containment isolation
- MSIV closure N/A1 51 -- 53Same
- FWIV closure
- Reactor trip For peak temperature case
- Same ECCS actuation on IAB release 92 Same pressure ECCS valve opening on pressure 15195 difference below IAB release pressure N/A Same for peak pressure case ECCS actuation on highPeak CNV level for peak temperature reached:
N/A109 495Same For peak pressure case: 510 °F For peak temperature case: Same ECCS valve opening for Peak CNV pressure is reached: N/A112 498Same For peak pressure case: 943 psia For peak temperature case: Same 169 Peak CNV pressure (906 psia) N/A N/A Peak CNV temperature (502 degrees F) 610 CNV pressure decreases to <50% of
~23001900 N/ASame peak pressure
© Copyright 2018 by NuScale Power, LLC 70
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-1 Case 1 containment vessel pressure - reactor coolant system discharge line break loss-of-coolant accident © Copyright 2018 by NuScale Power, LLC 71
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-2 Case 1 containment vessel wall temperature - reactor coolant system discharge line break loss-of-coolant accident 5.1.3.2 Case 2: Limiting Loss-of-Coolant Event - Reactor Coolant System Injection Line Break Loss-of-Coolant Accident The LOCA in the RCS injection line initiates an M&E release from the riser into the CNV. The results of the primary release event M&E release break spectrum analysis and sensitivity analyses have determined that Case 2 is the limiting LOCA peak pressure and overall limiting CNV wall temperature event. In addition, the analyses have shown that the Case 2 peak pressure results and CNV wall temperature results are ~1.76 and ~3.14.2 percent higher, respectively, than the next highest result (Case 1); therefore, there is confidence that the overall limiting break location and scenario has been identified. The sequence of events is shown in Table 5-3 and detailed results for key parameters are shown in Figures 5-3 through 5-16. The peak CNV wall temperature is 518514 degrees F for the reference case, and 523526 degrees F with the combined effect of the adverse sensitivity parameters. The sensitivity parameters that contribute to the +512 degrees F (~12.4 percent) increase are: (1) the timing of ECCS valve opening as determined by the IAB release and high CNV level setpoints and (2) the assumption of a loss of normal AC power. There was a small, adverse impact from the assumed (3) fine CNV volume & heat © Copyright 2018 by NuScale Power, LLC 72
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 structure nodalization and (4) single failure of one RRV failing to open. The peak CNV pressure is 904894 psia for the reference case, and 921959 psia with the combined effect of the adverse sensitivity parameters. The sensitivity parameters that contribute to the
+1765 psi (~27.3 percent) increase are: (1) the timing of ECCS valve opening as determined by the ECCS actuation setpoint, (2) the assumption of a loss of normal AC and DC power, and 3) high primary system flow. There was a small, adverse impact from the assumed (3) single failure of one RRV failing to open (4) fine CNV volume & heat structure nodalization and (5) the RPV noncondensable release to CNV. The detailed discussion of the Case 2 results that follow are for the limiting peak CNV pressure and temperature cases.
The sequence of events (Table 5-3) show that in the first seconds following the occurrence of a LOCA in the RCS injection line many automatic responses occur to transition the module from full power operation to an alignment that mitigates the initial LOCA blowdown phase. The break flow into the CNV causes a rapid pressurization that reaches the 9.5 psia high pressure setpoint. The following automatic actions occur on high CNV pressure:
- containment isolation resulting in MSIV and FWIV closure
- reactor trip
- turbine trip
- DHRS actuation (Note: DHRS actuation is conservatively not credited in the primary system containment response analysis methodology)
As a conservative assumption, either a loss of normal AC power or a loss of normal AC and DC power is also assumed to occur at the time of the break and the ECCS signal is actuated on high CNV level or IAB release pressure.low RPV level. In the containment response analysis methodology the ECCS setpoints are important analysis input as they determine the time of the second primary system M&E release into the CNV via the ECCS valvesRVVs. The peak CNV pressure and peak CNV wall temperature occur following the ECCS valvethis RVV actuation, after the CNV has been preheated by the initial LOCA M&E release. Following the alignment of the module for the LOCA blowdown phase, the primary system pressure and inventory decrease due to the loss of inventory through the LOCA. The CNV pressurizes and the steam condenses on the cold ID of the CNV. The condensate flows down the CNV walls and accumulates in a pool in the CNV lower head. The cold CNV wall absorbs the energy of the condensed steam and starts to heat up by conduction. Eventually the energy is transferred through the CNV wall to the reactor pool, and the pool temperature slowly increases. For the peak CNV wall temperature case, the ECCS signal actuates on high CNV level at 872952 seconds, and the opening of the ECCS valves occurs at 1158955 seconds (after the IAB release pressure is reacheda 3-second signal delay). The ECCS actuation and opening of the three RVVs and one RRV causes the peak CNV wall temperature to occur at 1180978 seconds. For the peak pressure case, the ECCS signal actuates on IAB release pressurehigh CNV level at 1078364 seconds, and the opening of the ECCS valves occurs at 1081367 seconds. The ECCS actuation and opening of the three RVVs and one RRV causes the peak CNV pressure to occur at 1100385 seconds. Then, as flow through the RVVs dimishes, the primary and CNV © Copyright 2018 by NuScale Power, LLC 73
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 pressures converge, and continued heat transfer to the CNV leads to a gradual cooldown and depressurization phase. Pressure equalization enables recirculation flow from the CNV pool through the RRVs to establish the long-term cooling recirculation alignment. The primary system response for the RCS injection line LOCA CNV peak pressure case is shown in Figures 5-3 through 5-9. Figure 5-3 shows the primary pressure response. The initial depressurization phase due to the LOCA is followed by the rapid depressurization when the RVVs open. Figures 5-4 and 5-5 show the inventory in the pressurizer and in the riser. These figures show the expected trend of a decreasing level in the primary followed by a stabilization in inventory, with some liquid holdup in the pressurizer. A sensitivity study that decreased the interphase drag in the upper riser, riser upper plenum, pressurizer baffle, pressurizer, and the downcomer, with the intent of reducing liquid entrainment, showed that there was no adverse impact on the peak CNV pressure for this case. Figure 5-6 shows the primary coolant temperatures at six locations. Following ECCS actuation the temperatures converge and the cooldown proceeds. Figure 5-7 shows the LOCA and ECCS mass flowrates althoughincluding the spike in mass release when ECCS valves open is not shown because of reduced plot frequency. Figures 5-8 and 5-9 show the integrated LOCA and ECCS mass flowrate and energy flowrate. Based on the integrated mass and energy flow rate plots, it is evident that the ECCS flow through the three RVVs into the CNV is significant. It is this M&E flow spike that causes the peak CNV pressure and wall temperatures to occur shortly thereafter as shown in Table 5-3. The CNV and reactor pool responses for the RCS injection line LOCA peak pressure case are shown in Figures 5-10 to 5-15. Figure 5-10 shows the CNV pressure response and the limiting LOCA value of 921959 psia. This NRELAP5 analysis result is approximately 811% below the CNV design pressure of 10001075 psia. This is a key result of this limiting LOCA containment pressure response analysis case. Pressure increases rapidly to the peak value immediately following opening of the RVVs. Figure 5-11 shows the CNV liquid level increase as the unflashed break flow and condensed steam accumulates. Figure 5-12 shows the CNV vapor temperature. ((
}}2(a),(c) Figure 5-13 shows the temperature profile across the CNV wall at the 45 foot elevation. There is a large temperature gradient across the CNV wall. Figure 5-14 shows the reactor pool temperatures for a range of elevations. The reactor pool temperature does not increase significantly for the short duration of these analyses. From Figures 5-13 and 5-14 it is evident that the NPM design provides an effective heat sink for these short-term M&E analyses. Even with the conservative initial reactor pool level of 5565 ft above the pool floor and a temperature of 140110 degrees F assumed in this analysis, the peak CNV wall temperature remains within the design limit.
Figure 5-15 shows the energy balance during the CVCS injection line LOCA and the trends of the heat sources and sinks. At approximately 14001000 seconds, the energy release © Copyright 2018 by NuScale Power, LLC 74
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 from the LOCA and the RVV valves decreases to below the energy transferred through the CNV wall. The CNV wall then continues to provide a strong heat sink for the sustained cooldown and depressurization of the module. As demonstrated by Table 5-3, the event progression for the RCS injection line LOCA peak pressure case and the peak CNV wall temperature case are similar. Accordingly, only the CNV pressure and wall temperature figures will be presented for the peak CNV wall temperature case. Figure 5-16 shows the CNV pressure response for the RCS injection line LOCA peak wall temperature case. Figure 5-17 shows the CNV wall temperature response for the RCS injection line LOCA peak CNV wall temperature case and the overall limiting value of 523526 degrees F. This limiting NRELAP5 is less than the CNV design temperature of 550 degrees F. This is a key result of this limiting containment wall temperature response analysis case. Table 5-3 Case 2 sequence of events for limiting containment vessel temperature event - reactor coolant system injection line break loss-of-coolant accident Peak CNV Pressure Case Event Peak CNV Temperature Case Time (sec) Time (sec) LOCA in RCS injection line For peak pressure case:
- Loss of normal AC power
- FW/MS isolation 500
- Reactor trip Same0 For peak temperature case:
- Loss of normal AC power
- FW/MS isolation High CNV pressure resulting in For peak pressure case:
- Containment isolation
- MSIV closure 52 - 553
- FWIV closure Same3 For peak temperature case:
- Containment isolation
- Reactor trip
- Turbine trip ECCS actuation on For peak pressure case:
1078364
- IAB release pressure 872952 For peak pressure case:
- high CNV level 1081367 ECCS valve opening 1158955 1100385 Peak CNV pressure (921 reached: N/A967
© Copyright 2018 by NuScale Power, LLC 75
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Peak CNV Pressure Case Event Peak CNV Temperature Case Time (sec) Time (sec) For peak pressure case: 959 psia) For peak temperature case: 939 psia Peak CNV temperature (523 degreesreached: N/A384 1180978 For peak pressure case: 509 °F) For peak temperature case: 526 °F CNV pressure decreases to <50% of
~30002200 N/A~2500 peak pressure Figure 5-3 Case 2 primary system pressure - reactor coolant system injection line break loss-of-coolant accident (peak pressure case)
© Copyright 2018 by NuScale Power, LLC 76
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-4 Case 2 pressurizer level - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 77
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-5 Case 2 riser level - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 78
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-6 Case 2 primary temperatures - reactor coolant system injection line break loss-of-coolant accident © Copyright 2018 by NuScale Power, LLC 79
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-7 Case 2 break and emergency core cooling system mass flowrate - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 80
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-8 Case 2 integrated loss-of-coolant accident and emergency core cooling system mass release - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 81
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-9 Case 2 integrated loss-of-coolant accident and emergency core cooling system energy release - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 82
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-10 Case 2 containment vessel pressure - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 83
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-11 Case 2 containment vessel level - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 84
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-12 Case 2 containment vessel vapor temperature - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 85
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-13 Case 2 containment vessel wall temperature profile -reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 86
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-14 Case 2 reactor pool temperatures - reactor coolant system injection line break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 87
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-15 Case 2 energy balance - reactor coolant system injection lIne break loss-of-coolant accident (peak pressure case) © Copyright 2018 by NuScale Power, LLC 88
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-16 Case 2 containment vessel pressure - reactor coolant system injection line break loss-of-coolant accident (peak CNV wall temperature case) © Copyright 2018 by NuScale Power, LLC 89
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-17 Case 2 containment vessel peak wall temperature - reactor coolant system injection line break loss-of-coolant accident (peak CNV wall temperature case) 5.1.3.3 Case 3: Reactor Pressure Vessel High Point Degasification Vent Line Loss-of-Coolant Accident The LOCA in the RPV high point degasification line initiates an M&E release from the top of the pressurizer into the CNV. The sequence of events is shown in Table 5-4. The CNV pressure response and temperature response are shown in Figures 5-18 and 5-19. The CNV peak CNV pressure is 586554 psia for the reference case, and 864901 psia with the combined effect of the adverse sensitivity parameters (loss of normal AC and DC power, 1200 psid IAB release pressure)., high RCS flow, fine CNV volume nodalization). The peak CNV wall temperature is 471476 degrees F for the reference case, and 484489 degrees F with the combined effect of the adverse sensitivity parameters (loss of normal AC and DC power, 9001000 psid IAB release pressure, RRV single failurehigh RCS flow, fine CNV volume nodalization). Case 3 is non-limiting. © Copyright 2018 by NuScale Power, LLC 90
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 5-4 Case 3 sequence of events - RPV high point degasification line break loss-of-coolant accident Peak CNV Pressure Case Event Peak CNV Temperature Case Time (sec) Time (sec) LOCA in RPV high point degasification line For peak pressure case only:
- Loss of normal AC and DC power 500 Same0
- ECCS actuation signal
- FW/MS isolation
- Reactor trip
- Containment isolation
- MSIV closure
- FWIV closure High CNV pressure resulting in For peak pressure case:
- Containment isolation 1 For peak temperature case: 1
- Reactor trip
- FW/MS isolation
- Loss of normal AC and DC power assumed at turbine trip ECCS valves openactuation on below :
9858 142106 IAB release pressure 61 ECCS valve opening 109 Peak CNV pressure (864reached: 11982 N/A128 For peak pressure case: 901 psia) For peak temperature case: 894 psia Peak CNV temperature (484 degreesreached: N/A454 437478 For peak pressure case: 487 °F) For peak temperature case: 489 °F CNV pressure decreases to <50% of
~23001900 N/A~2000 peak pressure
© Copyright 2018 by NuScale Power, LLC 91
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-18 Case 3 containment vessel pressure - pressurizer spray supplyhigh point vent line break loss-of-coolant accident © Copyright 2018 by NuScale Power, LLC 92
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-19 Case 3 containment vessel wall temperature - pressurizer spray supplyhigh point vent line break loss-of-coolant accident 5.1.3.4 Case 4: Inadvertent Reactor Vent Valve Opening Anticipated Operational Occurrence The inadvertent RVV actuation anticipated operational occurrence (AOO) initiates an M&E release from the top of the pressurizer into the CNV. The sequence of events is shown in Table 5-5. The CNV pressure response and temperature response are shown in Figures 5-20 and 5-21. The CNV peak CNV pressure is 802856 psia for the reference case, and 880911 psia with the combined effect of the adverse sensitivity parameters (loss of normal AC and DC power, 1200 psid IAB release pressure, minimum primary systemlow RCS flow)., fine CNV heat structure & reactor pool nodalization). The peak CNV temperature is 481483 degrees F for the reference case, and 482486 degrees F for the case with the combined effect of the adverse sensitivity parameters (loss of normal AC and DC power, 900 psid IAB release pressure). There was no sensitivity to any of the single failures. available, fine CNV volume nodalization). Case 4 is non-limiting. © Copyright 2018 by NuScale Power, LLC 93
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 5-5 Case 4 sequence of events - inadvertent reactor vent valve opening event Peak CNV Pressure Event Peak CNV Temperature Case Case Time (sec) Time (sec) Inadvertent RVV actuation For peak pressure case only:
- Loss of normal AC and DC power
- ECCS actuation signal 500 Same0
- FW/MS isolation
- Reactor trip
- Containment isolation
- MSIV closure
- FWIV closure High CNV pressure resulting in For peak pressure case:
- Containment isolation 0.2 For peak temperature case: 0.2
- Containment isolation
- Reactor trip
- FW/MS isolation ECCS valves openingactuation on below :
617 68n/a IAB release pressure 10 ECCS valves opening n/a Peak CNV pressure (880reached 7927 N/A57 For peak pressure case: 911 psia) For peak temperature case: 855 psia Peak CNV temperature (reached N/A361 256437 For peak pressure case: 482 degrees °F) For peak temperature case: 486 °F CNV pressure decreases to <50% of peak
~22001700 N/A~2000 pressure
© Copyright 2018 by NuScale Power, LLC 94
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-20 Case 4 containment vessel pressure - inadvertent reactor vent valve opening event © Copyright 2018 by NuScale Power, LLC 95
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-21 Case 4 containment vessel wall temperature - inadvertent reactor vent valve opening event 5.1.3.5 Case 5: Limiting Overall Containment Vessel Pressure Event - Inadvertent Reactor Recirculation Valve Opening Anticipated Operational Occurrence The inadvertent RRV actuation initiates an M&E release from the downcomer into the CNV. The results of the primary release event M&E release break spectrum analysis and sensitivity analyses have determined that this AOO (Case 5) results in the limiting peak CNV pressure for all postulated events. The sequence of events is shown in Table 5-6, and detailed results for key parameters are shown in Figures 5-22 through 5-35. The CNV peak CNV pressure is 933941 psia for the reference case, and 951986 psia with the combined effect of the adverse sensitivity parameters. The sensitivity parameters that contribute to the +1845 psi (~1.94.8 percent) increase are: (1) the timing of the ECCS valve opening as determined by the IAB release pressureand high CNV level setpoint; (2) the assumption of a loss of normal AC and DC power; and (3) minimum primary system flow. There was no adverse impact from the single failure sensitivity studies. of an RRV; (4) fine CNV volume & heat structure and reactor pool nodalization; (5) fast RPV non-condensable release to CNV; and (6) low RCS flow. The peak CNV temperature is 495492 degrees F for the reference case, and 506512 degrees F with the combined effect of the adverse sensitivity parameters. The Case 5 peak CNV pressure case is the same case as the Case 5 peak CNV wall temperature case. (loss of normal AC power, low-biased high CNV level setpoint, single failure of an RRV, fine CNV volume & reactor pool nodalization). © Copyright 2018 by NuScale Power, LLC 96
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 The sequence of events (Table 5-6) shows that in the first seconds following the occurrence of an inadvertent RRV event many automatic responses occur to transition the module from full-power operation to an alignment that mitigates the initial blowdown phase. The break flow into the CNV causes a rapid pressurization that reaches the 9.5 psia high pressure setpoint. The following automatic actions occur on high CNV pressure:
- containment isolation resulting in MSIV and FWIV closure
- reactor trip
- turbine trip
- DHRS actuation (Note: DHRS actuation is not credited in the primary system containment response analysis methodology)
As a conservative assumptionFor the peak temperature case, a loss of normal AC power is assumed to occur at the time of the break. RRVs and RVVs opening does not occur until the high CNV level setpoint is reached. In the containment response analysis methodology the high CNV level setpoint is an important analysis input as it determines the second primary system M&E release into the CNV through the RVVs and the second RRV. The peak CNV wall temperature occurs following the RVVs opening after the CNV has been preheated by the initial M&E release. For the peak pressure case, a loss of normal AC and DC power is also assumed to occur at the time of the break. This results in an ECCS signal. However, RRVs and RVVs opening does not occur until the differential pressure across the valve decreases to below the IAB release pressure. In the containment response analysis methodology the IAB release pressure is an important analysis input as it determines the second primary system M&E release into the CNV through the RVVs and the second RRV. The peak CNV pressure and peak CNV wall temperature occur following the RVVs opening after the CNV has been preheated by the initial M&E release. Following the alignment of the module for blowdown, the primary system pressure and inventory decrease due to the loss of inventory. The CNV pressurizes and the steam condenses on the cold interior wall of the CNV. The condensate flows down the CNV walls and accumulates along with unflashed break liquid in a pool in the CNV lower head. The cold CNV wall absorbs the energy of the condensed steam and starts to heat up by conduction. Eventually the energy is transferred through the CNV wall to the reactor pool, and the pool temperature slowly increases. Opening of the RVVsECCS valves occurs at 127171 seconds for the peak temperature case (when the high CNV level setpoint is reached) and at 77 seconds for the peak pressure case (when the RCS pressure decreases to below the 1000 psid IAB release pressure), as determined by the results of sensitivity analyses. OpeningFor the peak temperature case, opening of the three RVVs and the second RRV results in the peak CNV pressure and wall temperature at 143 and 189 seconds, respectively.182 and 180 seconds, respectively. For the peak pressure case, opening of the three RVVs and the second RRV results in the peak CNV pressure and wall temperature at 91 and 596 seconds, respectively. As flow through the RVVs dimishes, the primary and CNV pressures converge, and continued heat transfer to the CNV leads to a gradual cooldown and depressurization phase. Pressure equalization enables recirculation flow from the CNV pool through the RRVs to establish the long-term cooling recirculation alignment. © Copyright 2018 by NuScale Power, LLC 97
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 The primary system response for the Case 5 inadvertent RRV opening event (peak pressure case) is shown in Figures 5-22 through 5-28. Figure 5-22 shows the primary pressure response. The initial depressurization phase due to the RRV opening is continued by the rapid depressurization when the RVVs open. Figures 5-23 and 5-24 show the inventory in the pressurizer and in the riser. These figures show the expected trend of a decreasing level in the primary followed by a stabilization in inventory, with some liquid holdup in the pressurizer. A sensitivity study that decreased the interphase drag in the upper riser, riser upper plenum, pressurizer baffle, pressurizer, and the downcomer with the intent of reducing liquid entrainment, showed that there was no adverse impact on the peak CNV pressure for this case. Figure 5-25 shows the primary coolant temperatures at six locations. Following ECCS actuation the temperatures converge and the cooldown proceeds. Figure 5-26 shows the RRV opening and ECCS mass flowrates. It is evident that the ECCS flow immediately following ECCS actuation, mainly the flow through the three RVVs into the CNV, is significant. It is this flow spike that causes the peak CNV pressure and wall temperatures to occur shortly thereafter as shown in Table 5-6. Figures 5-27 and 5-28 show the integrated LOCA and ECCS mass flowrate and energy flowrate. The CNV and reactor pool response for the Case 5 inadvertent RRV actuation LOCA is shown in Figures 5-29 to 5-34. Figure 5-29 shows the CNV pressure response and how pressure rapidly increases to the limiting peak value of 951986 psia. This limiting NRELAP5 result can be compared to the CNV design pressure of 10001075 psia. This is a key result of this limiting containment response analysis case. Figure 5-29 also demonstrates the long term cooling capability of the UHS. CNV pressure is reduced to below 50 percent of the peak value within two hours of accident initiation. Figure 5-30 shows the CNV liquid level increase as the unflashed break flow and condensed steam accumulates. Figure 5-31 shows the CNV vapor temperature. Initially, flashing of the break flow at low CNV pressure results in a temperature decrease. ((
}}2(a),(c) Figure 5-32 shows the peak CNV wall temperature and the limiting value of 506492 degrees F. Figure 5-33 shows the temperature profile across the CNV wall at the 45 foot elevation. There is a large temperature gradient across the CNV wall. Figure 5-34 shows the reactor pool temperatures for a range of elevations. The reactor pool temperature does not increase significantly for the short duration of these M&E release analyses. From Figures 5-31 through 5-34 it is evident that the CNV wall is the significant heat sink in the short-term. Even with the conservative initial reactor pool level of 5565 ft above the pool floor and a temperature of 140110 degrees F assumed in these analyses, the CNV wall is capable of maintaining the peak CNV pressure within the design limit.
Figure 5-35 shows the energy balance during the RRV loss-of-coolant accident and the trends of the heat sources and sinks. At approximately 700750 seconds the energy release from the LOCA and the RVV valves decreases to below the energy transferred through the CNV wall. The CNV wall then continues to provide a strong heat sink for the sustained cooldown and depressurization of the module. © Copyright 2018 by NuScale Power, LLC 98
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 5-6 Case 5 sequence of events - inadvertent reactor recirculation valve opening event Peak CNV Pressure Event Peak CNV Temperature Case Case Time (sec) Time (sec) 500 Inadvertent RRV actuation:Actuation 0 For peak temperature case
- Loss of normal AC power
- FW/MS isolation For peak pressure case
- Loss of normal AC and DC power
- ECCS actuation signal
- FW/MS isolation
- Reactor trip
- Containment isolation
- MSIV closure
- FWIV closure High CNV pressure resulting in:
For peak temperature case
- Containment isolation 0.4 0.4
- Reactor trip For peak pressure case
- Containment isolation 12774 ECCS valve openingactuation on 168 differential:
For peak temperature case
- high CNV level For peak pressure belowcase
- IAB release pressure
(<1000psid) 77 ECCS valve opening 171 14391 Peak CNV pressure reached: 182 For peak pressure case: 986 psia For peak temperature case: 967 psia 189596 Peak CNV temperature reached: 180 For peak pressure case: 492 °F For peak temperature case: 512 °F
~21001800 CNV pressure decreases to <50% of ~1800 peak pressure
© Copyright 2018 by NuScale Power, LLC 99
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-22 Case 5 primary pressure - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 100
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-23 Case 5 pressurizer level - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 101
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-24 Case 5 riser level - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 102
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-25 Case 5 primary temperature - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 103
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-26 Case 5 loss-of-coolant accident and emergency core cooling system flowrate - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 104
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-27 Case 5 integrated loss-of-coolant accident and emergency core cooling system mass flow rate - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 105
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-28 Case 5 integrated loss-of-coolant accident and emergency core cooling system energy release - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 106
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-29 Case 5 containment vessel pressure - inadvertent reactor recirculation valve opening event (overall limiting pressure case) © Copyright 2018 by NuScale Power, LLC 107
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-30 Case 5 containment vessel level - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 108
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-31 Case 5 containment vessel vapor temperature - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 109
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-32 Case 5 containment vessel wall temperature - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 110
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-33 Case 5 containment vessel wall temperature profile - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 111
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-34 Case 5 reactor pool temperature - inadvertent reactor recirculation valve opening event © Copyright 2018 by NuScale Power, LLC 112
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-35 Case 5 energy balance - inadvertent reactor recirculation valve opening event 5.2 Main Steamline Break Pressure and Temperature Results The sequence of events (Table 5-7) show that in the first seconds following the occurrence of a MSLB many automatic responses occur to transition the module from full power operation to an alignment that mitigates the secondary system blowdown. The break flow into the CNV causes a rapid pressurization that reaches the 9.5 psia high pressure setpoint. The following automatic actions occur on high CNV pressure:
- containment isolation including MSIV and FWIV closure
- reactor trip
- turbine trip
- DHRS actuation (Note: no DHRS operation is credited for this event analysis)
Following the alignment of the module to mitigate the secondary blowdown, the secondary system pressure and inventory decrease due to the loss of inventory through the break. With continued normal AC power the feedwater pump initially continues to operate and supply the SGs. Feedwater isolation then terminates the supply of feedwater to the affected SG and effectively mitigates the event. The CNV pressurizes and the steam © Copyright 2018 by NuScale Power, LLC 113
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 condenses on the cold ID of the CNV. The condensate flows down the CNV walls and accumulates in a pool in the CNV lower head. The cold CNV wall absorbs the energy of the condensed steam and starts to heat up by conduction. Eventually the energy is transferred through the CNV wall to the reactor pool, and the pool temperature slowly increases. The module response for the MSLB is shown in Figures 5-36 through 5-51. Figure 5-36 shows the SG pressure response with the affected SG (SG2) depressurizing via blowdown out the break into the CNV. The unaffected SG (SG1) initially depressurizes until the MSIV closes, and then gradually pressurizes following DHRS actuationisolation. Figure 5-37 shows the primary system temperature response due to the initial secondary system blowdown and then following DHRS actuation secondary side isolation. Figure 5-38 shows the primary system pressure response with the initial depressurization following secondary system blowdown, and then the pressure increasing from operation of the pressurizer heaters during DHRS operation following secondary side isolation. Figure 5-39 shows that the pressurizer level rapidly decreases during the initial overcooling, and then gradually decreasesincreases in response to the decrease in primary temperatures during DHRS operationfollowing secondary side isolation. Figures 5-40 through 5-42 show the secondary system mass release, the integrated mass release, and the integrated energy release into the CNV, respectively. The liquid entrainment in the break flow was negligible, and therefore the sensitivity study on interphase drag upstream of the break flow was not necessary. The CNV and reactor pool responses for the MSLB are shown in Figures 5-43 to 5-48. Figure 5-43 shows the CNV pressure response. The pressure rapidly increases to the limiting peak value of 419449 psia at 4142 seconds. This limiting NRELAP5 result can be compared to the CNV design pressure of 10001075 psia, and to the limiting primary release event result. The MSLB result is bounded by the limiting LOCA (Case 2) and overall limiting primary release event result (Case 5). This is a key result in this MSLB containment response analysis. Figure 5-44 shows the CNV vapor temperature. ((
}}2(a),(c) Figure 5-45 shows the peak CNV wall temperature and the limiting value of 427428 degrees F at 4641 seconds. This limiting NRELAP5 result can be compared to the CNV design temperature of 550 degrees F, and to the limiting LOCA result. The MSLB result is bounded by the limiting primary release event result (Case 2).
This is a key result in this MSLB containment response analysis. Figure 5-46 shows the CNV level response. Figure 5-47 shows the temperature profile across the CNV wall. There is a large temperature gradient. Figure 5-48 shows the reactor pool temperatures for a range of elevations. The reactor pool temperature does not increase significantly for the short duration of these analyses. From these results it is evident that the CNV wall is the significant heat sink for these containment response analyses. Even with the conservative initial reactor pool level of 5565 ft above the pool © Copyright 2018 by NuScale Power, LLC 114
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 floor and a temperature of 140110 degrees F assumed in these analyses, the CNV wall is capable of maintaining the peak CNV pressure and temperature within the design limit. Figure 5-49 shows the energy balance during the MSLB and the trends of the heat sources and sinks. At approximately 500300 seconds the energy release from the MSLB has dimished, and the energy transfer through the CNV wall and from the DHRS to the pool dominate. This energy balance is consistent with the cooldown of the primary system shown in Figure 5-37. Table 5-7 Main steam line break sequence of events Time (sec) Event 0 MSLB 0 - 24 Low steam line pressure resulting in
- Reactor trip
- Turbine trip
- MSIV closure
- FWIV closure
- DHRS actuation High CNV pressure resulting in
- Containment isolation 3234 Closure of FWRV complete 4142 Peak CNV pressure 4641 Peak CNV temperature
~200 CNV pressure decreases to <50% of peak pressure
© Copyright 2018 by NuScale Power, LLC 115
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-36 Main steam line break steam generator pressure © Copyright 2018 by NuScale Power, LLC 116
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-37 Main steam line break primary temperature © Copyright 2018 by NuScale Power, LLC 117
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-38 Main steam line break primary system pressure © Copyright 2018 by NuScale Power, LLC 118
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-39 Main steam line break pressurizer level © Copyright 2018 by NuScale Power, LLC 119
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-40 Main steam line break and emergency core cooling system flowrate © Copyright 2018 by NuScale Power, LLC 120
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-41 Main steam line break and emergency core cooling system integrated mass release © Copyright 2018 by NuScale Power, LLC 121
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-42 Main steam line break integrated energy release © Copyright 2018 by NuScale Power, LLC 122
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-43 Main steam line break containment vessel pressure © Copyright 2018 by NuScale Power, LLC 123
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-44 Main steam line break containment vessel vapor temperature © Copyright 2018 by NuScale Power, LLC 124
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-45 Main steam line break containment vessel wall temperature © Copyright 2018 by NuScale Power, LLC 125
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-46 Main steam line break containment vessel level © Copyright 2018 by NuScale Power, LLC 126
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-47 Main steam line break containment vessel wall temperature profile © Copyright 2018 by NuScale Power, LLC 127
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-48 Main steam line break reactor pool temperature © Copyright 2018 by NuScale Power, LLC 128
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-49 Main steam line break energy balance 5.3 Feedwater Line Break Pressure and Temperature Results The sequence of events (Table 5-8) show that in the first seconds following the occurrence of an FWLB many automatic responses occur to transition the module from full power operation to an alignment that mitigates the initial secondary system blowdown phase. The break flow into the CNV causes a rapid pressurization that reaches the 9.5 psia high pressure setpoint. The following automatic actions occur on high CNV pressure:
- containment isolation including MSIV closure and FWIV closure
- DHRS actuation
- reactor trip
- turbine trip As a conservative assumption a loss of normal AC and DC power is also assumed to occur at the time of turbine tripevent initiation. This results in an ECCS signal. However, opening of the emergency core cooling system RRVs and RVVs does not occur until the pressure differential decreases to below the IAB release pressure. In the containment response
© Copyright 2018 by NuScale Power, LLC 129
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 analysis methodology the IAB release pressure is an important analysis input as it determines the second M&E release into the CNV via the RVVs. A higher IAB release pressure results in an earlier opening of the ECCS valves when the RCS is hotter. The peak CNV pressure and peak CNV wall temperature occur following the RVV actuation, after the CNV has been preheated by the initial M&E release. Sensitivity studies of single failures have determined that a failure of a FWIVMSIV to close had an adverse impact on the CNV peak pressure and temperature results. Following the alignment of the module to mitigate the initial secondary blowdown phase, the secondary system pressure and inventory decrease due to the loss of inventory. The CNV pressurizes and the steam condenses on the cold ID of the CNV. The condensate flows down the CNV walls and accumulates with unflashed secondary break liquid in a pool in the CNV lower head. The cold CNV wall absorbs the energy of the condensed steam and starts to heat up by conduction. Eventually the energy is transferred through the CNV wall to the reactor pool, and the pool temperature slowly increases. After the end of the secondary blowdown phase decay heat removal is via the DHRS. Opening of the ECCS valves occurs at 12,01211,566 seconds when the pressure differential decreases to below the 1200 psid IAB release pressure. This causes the CNV peak CNV pressure (442416 psia) and the peak CNV wall temperature (414407 degrees F) at ~11,60012,058 and ~12,20011,870 seconds, respectively. As flow through the RVVs dimishes, the primary system and CNV pressures converge, and continued heat transfer to the CNV leads to a gradual cooldown and depressurization phase. Pressure equalization enables recirculation flow from the CNV pool through the RRVs to establish the long-term cooling recirculation alignment. The module response for the FWLB analysis is shown in Figure 5-50 through Figure 5-64. Figure 5-50 shows the SG pressure response with the affected SG (SG2) depressurizing via blowdown out the break into the CNV and stabilizing at a low pressure of approximately 30 psia. The unaffected SG (SG1) pressure fluctuates in response to DHRS heat transfer. The affected SG repressurizes by reverse break flow on ECCS valve opening. Then, both SGs depressurize as ECCS heat transfer dominates. Figure 5-51 shows the gradual primary system cooldown due to DHRS, and the increase in the cooldown rate with the opening of the ECCS valves. Figure 5-52 shows the relatively steady pressurizer level decrease during DHRS cooling and then a rapid level decrease when ECCS valves open. Figure 5-53 shows the riser level remaining full until the ECCS valves open, and then level rapidly decreases before stabilizing. Primary system pressure (Figure 5-54) gradually decreases during the DHRS cooldown period due to loss of pressurizer heaters and then rapidly depressurizes on ECCS valves opening. Figure 5-55 through Figure 5-57 show the break and ECCS mass release, the integrated mass release, and the integrated energy release into the CNV, respectively. The FWLB flow rate and integrated mass release is not significant due to the small SG inventory. Due to the insignificance of the secondary break flow, the effect of liquid entrainment is also insignificant. The primary system M&E release through the three RVVs is the significant M&E release event for the FWLB accident. The CNV and reactor pool responses for the FWLB are shown in Figure 5-58 through Figure 5-63. Figure 5-58 shows the CNV pressure response. The initial M&E release results in the CNV pressurizing to ~60 psia before heat transfer to the CNV wall results in pressure stabilizing at ~15 psia. Then pressure rapidly increases to the limiting peak value of 442416 psia following opening of the RVVs. This limiting NRELAP5 result can be © Copyright 2018 by NuScale Power, LLC 130
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 compared to the CNV design pressure of 10001075 psia and to the limiting MSLB and primary release event results. The FWLB peak CNV pressure result is higher than the MSLB result, but is bounded by the limiting LOCA results. This is a key result in this FWLB containment response analysis. Figure 5-59 shows the CNV vapor temperature. ((
}}2(a),(c) Figure 5-60 shows the peak CNV wall temperature and the limiting value of 414407 degrees F.
This limiting NRELAP5 result can be compared to the CNV design temperature of 550 degrees F, and to the limiting MSLB and LOCA results. The FWLB is bounded by both the MSLB result and the limiting primary release event results. This is a key result in this FWLB containment response analysis. Figure 5-61 shows the CNV level response with an initial level increase following the initial M&E release, and the second level increase following the delayed opening of the ECCS valves. Figure 5-62 shows the temperature profile across the CNV wall at the 45 foot elevation. A significant temperature gradient exists. Figure 5-63 shows the reactor pool temperature for a range of elevations. Clearly the reactor pool temperature does not increase significantly through the time of peak CNV pressure and temperature. Even with the conservative initial reactor pool level of 5565 ft above the pool floor and a temperature of 140110 degrees F assumed in these analyses, the CNV wall is capable of maintaining the peak CNV pressure and temperature within the design limit. Figure 5-64 shows the energy balance during the FWLB and the trends of the heat sources and sinks. The DHRS and CNV wall heat sinks combine to exceed the ECCS energy release and results in a sustained cooldown of the primary system as shown in Figure 5-51. © Copyright 2018 by NuScale Power, LLC 131
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Table 5-8 Feedwater line break sequence of events Time (sec) Event 0 FWLB
- Loss of normal AC and DC power at event initiation resulting in ECCS actuation signal
- Reactor trip
- Turbine trip High CNV pressure resulting infollowed by:
0 - 2.6
- Containment isolation o* MSIV closure o* FWIV closure o* DHRS actuation
- Reactor trip
- Turbine trip
- Loss of normal AC and DC power on turbine trip resulting in ECCS actuation signal 10~12 Peak CNV pressure from secondary M&E release 12,01211,566 ECCS valve opening on differential pressure below IAB release pressure (<1200psid)
Peak CNV pressure
~12,058~11,600 ~12,200~11,870 Peak CNV temperature ~13,000 CNV pressure decreases to <50% of peak pressure
© Copyright 2018 by NuScale Power, LLC 132
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-50 Feedwater line break steam generator pressure © Copyright 2018 by NuScale Power, LLC 133
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-51 Feedwater line break primary temperature © Copyright 2018 by NuScale Power, LLC 134
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-52 Feedwater line break pressurizer level © Copyright 2018 by NuScale Power, LLC 135
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-53 Feedwater line break riser level © Copyright 2018 by NuScale Power, LLC 136
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-54 Feedwater line break primary system pressure © Copyright 2018 by NuScale Power, LLC 137
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-55 Feedwater line break and emergency core cooling system flowrate © Copyright 2018 by NuScale Power, LLC 138
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-56 Feedwater line break and ECCS integrated mass release © Copyright 2018 by NuScale Power, LLC 139
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-57 Feedwater line break and ECCS integrated energy release © Copyright 2018 by NuScale Power, LLC 140
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-58 Feedwater line break containment vessel pressure © Copyright 2018 by NuScale Power, LLC 141
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-59 Feedwater line break containment vessel vapor temperature © Copyright 2018 by NuScale Power, LLC 142
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-60 Feedwater line break containment vessel wall temperature © Copyright 2018 by NuScale Power, LLC 143
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-61 Feedwater line break containment vessel level © Copyright 2018 by NuScale Power, LLC 144
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-62 Feedwater line break containment vessel wall temperature profile © Copyright 2018 by NuScale Power, LLC 145
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-63 Feedwater line break reactor pool temperature © Copyright 2018 by NuScale Power, LLC 146
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Figure 5-64 Feedwater line break energy balance 5.4 Margin Assessment The following subsections discuss the analytical and design margin incorporated into the NPM design. Section 5.4.1 describes margin inherent in the enhanced requirements imposed on the CNV as an American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC) Class 1 vessel. Section 5.4.2 describes conservative modeling assumptions in the containment peak pressure and temperature analysis, along with the results of a nominal case quantifying the conservatism resulting from some of these assumptions. 5.4.1 Containment Vessel Design Atmospheric Pressure Margin The CNV consists of an upper section and a lower section joined at the closure flange about one third of the way up the vessel. The CNV upper section is made of SA-508 Grade 3, Class 2 low alloy steel with 0.125-in. stainless steel cladding on the inside surfaces and 0.250-in. stainless steel cladding on the outside surface. The top head of the upper section is a torispherical head and the vessel shell has an OD of 176.75 in. and a base metal wall thickness of 3.00 in. The CNV lower section is made of SA-965 FXM-19 austenitic stainless steel and does not require any cladded surfaces. The bottom head on the lower section is a torispherical head and the vessel shell consists of three regions. The bottom region, in the area of the fuel, has an OD of 134.50 in. and a wall thickness of 3.00 in., the © Copyright 2018 by NuScale Power, LLC 147
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 middle region is a transition between the diameters of the bottom and top region. The top region has an OD of 176.50 in. with a wall thickness of 3.250 in. Containment vessel shell-to-shell, shell-to-head, and penetration-to-shell welds are high-quality, full-penetration welds performed in the vessel fabrication shop. Material properties of the structural portions of the CNV are summarized in Table 5-9. Table 5-9 Containment vessel material properties Material Property (ksi) Material Sm Sy Su 140 F 550 F 140 F 550 F 140 F 550 F SA-508 Grade 3, 30.0 30.0 62.5 55.4 90.0 90.0 Class 2 SA-965 FXM-19 33.2 29.45 49.8 38.1 99.7 88.4 The CNV has a design pressure of 1,000 psia and design temperature of 550 degrees F. The limiting LOCA peak containment pressure is 921 psia and the overall peak containment pressure is 951 psia. The design pressure meets the requirements of ASME Boiler and Pressure Vessel Code (BPVC), Section III, Paragraph NCA-2142.1(a) and NB-3112.1(a) by bounding the most severe Level A service level pressure and ASME BPVC, Section III, Paragraph NE-7120(b) by not exceeding service limits specified in the design specification. The CNV is designed, fabricated, inspected and tested as an ASME Code Class 1 component in accordance to ASME BPVC, Section III, Subsection NB. Pressure boundary forgings and weld filler materials are tested for mechanical and fracture toughness to the requirements of ASME BPVC, Section III, Article NB-2000. The CNV is a high-quality, shop-fabricated vessel, made to the requirements of ASME BPVC, Section III, Article NB-4000, with low-alloy welds post weld heat treated. Many requirements between an NB and MC vessel are similar. However, one substantive difference between an NB and MC class vessel is in weld inspection. The main welds forming the pressure boundary shell are Category A, B and C full penetration, butt welds. In an NB class vessel these welds are required to have a volumetric and either liquid penetrant or magnetic particle inspection performed per ASME BPVC, Section III, Subarticle NB-5200. The corresponding welds in an MC class vessel only require a fully radiographed inspection per ASME BPVC, Section III, Subarticle NE-5200. By only performing a radiograph examination of the weld, all potential flaws in the weld may not be detected, which reduces the quality and potentially the strength of the weld. After fabrication of the CNV is completed, a shop hydrostatic test of the vessel is performed per ASME BPVC, Section III, Article NB-6000. Before hydrostatic testing, 100 percent of the pressure boundary welds are inspected. Inspection is performed to ASME BPVC, Section III, Subsubarticle NB-5280 and Subarticle IWB-2200 using examination methods of ASME BPVC Section V except as modified by ASME BPVC, Section III, Paragraph NB-5111. The hydrostatic test is done to a minimum pressure of 1,265 psia (125 percent) and a maximum pressure of 1,340 psia at a minimum temperature of 70 degrees F and a maximum temperature of 140 degrees F. The hydrostatic pressure and © Copyright 2018 by NuScale Power, LLC 148
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 temperature is held for a minimum of 10 minutes. The pressure is then decreased to design pressure and held for a minimum of four hours and then inspected for leaks. After the test is completed, the pressure boundary welds are inspected again to the same requirements used before the test. The NB-6000 hydrostatic test is performed to a greater pressure then required by NE-6000. NE-6321 specifies a minimum test pressure of only 110 percent and NE-6322 a maximum of 116 percent. The NuScale CNV is tested to a pressure margin 15 percent greater than conventional steel containment structures. The ASME BPVC provides allowable stress limits to prevent gross failure of vessels. Analysis of primary stresses for the CNV shows that the most limiting cross sections occur in the general section of the shells. Table 5-10 summarizes the design condition (1,000 psia and 550 degrees F) stress results for the upper and lower CNV. The table shows that the upper and lower CNV stresses in the shells have 3.8 percent and 9.5 percent margin to the ASME allowable stresses, respectively. The upper and lower CNV rated design pressure could be increased by the margins to 1,038 psia and 1,095 psia, respectively. A comparison of the limiting LOCA peak pressure (921 psia) and the maximum overall peak containment pressure (951 psia) to the increased pressure ratings of the upper and lower shells shows is provided by Table 5-10, when the margin between the maximum membrane stresses to the ASME allowable stresses is considered. Table 5-10 Design condition stress summary Increased Maximum Allowable Stress to Increased Increased overall CNV Membrane Membrane allowable CNV rated LOCA peak peak Section Stress Stress, Sm margin pressure pressure pressure (ksi) (ksi) (%) (psia) margin (%) Margin Upper 28.86 30.00 3.8 1,038 13.7 9.1 CNV shell Lower 26.64 29.45 9.5 1,095 18.9 15.1 CNV shell Additionally, the upper CNV shell is low alloy steel with stainless steel cladding on both sides. The base metal of the upper section is 3.00 in. Cladding adds an additional 0.375 in. to the thickness. This is an increase of 12.5 percent in thickness and therefore an increase in pressure capacity. The increase in thickness proportionally increases pressure capacity of the CNV. While in the ASME Code calculations cladding is neglected, the additional material does provide additional margin. When this margin is considered the increased pressure rating of the upper CNV becomes 1.125*1,038 psia = 1,168 psi. The margin of maximum containment peak pressure (951 psia) to the increased rated pressure of the upper CNV is 22.8. percent. NuScale analyses do not couple the internal and external containment pressures. Internal pressures are conservatively evaluated with an assumed external pressure of 0 psia. The atmospheric pressure, acting against the exterior CNV surface, is neglected. The overall limiting peak CNV peak pressure results from an inadvertent reactor recirculation valve opening anticipated operational occurrence with a loss of normal AC © Copyright 2018 by NuScale Power, LLC 149
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 and DC power. The overall limiting CNV peak pressure, is 986 psia, which is approximately 8 percent below the design pressure of 1075 psia, which occurs at a CNV elevation at the bottom of the CNV. Atmospheric pressure and reactor pool hydrostatic head, acting against the CNV exterior surface, provides approximately 22 psi additional margin, that is not credited by the CNV response analysis methodology. This demonstrates additional margin in the CNV design that is not considered by the containment design pressure ratingresponse analysis. 5.4.2 Decay Heat Removal System Availability The LOCA (Case 2) and AOO Case 2 and (Case 5) are performed with and without DHRS available to estimate the impact of DHRS availability on the CNV peak pressure response. The DHRS is conservatively not credited in the design basis containment response analysis cases. The NRELAP5 code has not been validated to cover DHRS performance during LOCAs or valve opening events. However, the DHRS is a single-failure proof safety-related system that can be credited in the future, with additional NRELAP5 validation, if the CNV pressure margin is reduced for any reason (design changes). The results of the DHRS available cases indicate that more than 25 psiaabout 37 psi additional margin could be gained by credit for DHRS availability. 5.4.3 Conclusion The NPM design provides sufficient margin to satisfy the requirements of GDC 16 and 50. The LOCA peak pressure provides approximately 11% and the AOO peak pressure provides approximately 8% margin to the CNV design pressure of 1075 psia, to address the acceptance criteria given by DSRS Section 6.2.1.1.A (See Table 2-2). The CNV response to the limiting LOCA event and AOO transient are conservatively calculated and demonstrate that the peak calculated pressures are below the CNV design pressure and decrease in pressure to one-half of the peak value within 24 hours. Further assurance of sufficient margin is provided through consideration of the robust designatmospheric pressure and hydrostatic head, acting against the CNV exterior surface and construction of the NPM and conservative assumptions related to the creditingavailability of the DHRS system in the containment response analysis. Consideration of external pressure acting against the CNV exterior surface reduces the differential pressure across the CNV wall by about 22 psi. The determination of NPM design pressure, in accordance with ASME Class 1 criteria, is conservative relative to Class MC and CC containments. This design pressure does not consider the additional margin provided by the internal and external cladding of the upper CNV shell. The effect of DHRS actuation in reducing peak containment pressure was not credited in the containment response analysis. Consideration of the effect of DHRS actuation, along with external pressure acting against the CNV exterior surface, reduces the differential across the CNV wall by approximately 59 psi. The containment response analysis methodology, analysis results and further conservatisms related to design and system operation provide assurance that the NPM design demonstrates sufficient margin to satisfy the requirements of GDC 16 and 50. © Copyright 2018 by NuScale Power, LLC 150
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 6.0 Summary and Conclusions This report presents the NuScale containment response analysis methodology for determining primary system and secondary system mass and energy releases and the resultant CNV pressure and temperature response for the NPM. A spectrum of LOCAs and ECCS valve opening events were analyzed along with the MSLB and FWLB accidents. The scope of the methodology is the short-term CNV response for comparison to the CNV pressure and temperature design limits. Equipment qualification and the long-term NPM response are not in the scope of this report. The containment response analysis methodology uses the NRELAP5 code, which originates from the RELAP5-3D© code. The NRELAP5 code includes new capabilities added by NuScale to enable modeling of the design features and transient response of the NPM. The NRELAP5 model of the NPM used in the containment response analysis methodology is based on the NuScale LOCA and non-LOCA evaluation models with limited revisions and additions necessary for application in the containment response analysis methodology. NuScale has completed LOCA and non-LOCA phenomena identification and ranking tables. The results of the PIRTs have been used in the development of the NRELAP5 code and model. The NRELAP5 LOCA and non-LOCA models have been assessed by comparison to generic separate effects tests and intergral effects test, as well as to the NuScale design-specific NIST-1 facility separate effects and integral LOCA tests. The containment response analysis methodology is shown to meet the intent of Section 6.2 of the NuScale DSRS. Based on the systematic application of conservative initial conditions and boundary conditions in the containment response analysis methodology, the margin in the containment response analysis methodology is judged to be sufficient. Conservative NRELAP5 demonstration analyses of the containment response analysis methodology have been performed for a spectrum of primary system LOCAs and ECCS valve opening events, and for the MSLB and FWLB accident secondary system events. Sensitivity studies have been used to identify the bounding scenarios and trends. The following insights were obtained:
- The bounding scenarios for both peak CNV pressure and temperature were determined to be primary system release events. The secondary system break events may include ECCS actuation, which essentially combines an initial secondary system M&E release with a subsequent primary system M&E release, but they are non-limiting scenarios.
- The limiting M&E release scenario is characterized by an initial heatup and pressurization of the CNV due to the LOCA or ECCS valve opening, and then the subsequent opening of the RVVs on following the pressure differential decreasing to below the IAB release pressure. It is the second M&E release that drives the CNV to the peak CNV pressure and peak CNV wall temperature results.
- The heat capacity of the CNV wall, rather than heat transfer to the reactor pool, provides the short-term heat sink to limit the peak CNV pressure and temperature.
© Copyright 2018 by NuScale Power, LLC 151
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10
- For the limiting cases the results of the sensitivity studies, including postulated single failures and the loss of normal AC and DC power, showed only a limited impact (~<1 percent) on the key figures-of-merit. The loss of normal AC and DC power and the timing of ECCS valve opening were the most important sensitivity parameters.
The limiting LOCA peak pressure and CNV wall temperature are a result of the reactor coolant system (RCS) injection line break. The LOCA limiting peak CNV wall temperature is approximately 523526 degrees F and it results from a reactor coolant system injection line break case, with a loss of normal alternating current (AC) power. The LOCA limiting peak pressure is 921approximately 959 psia, which also results from a reactor coolant system injection line break case, with a loss of normal AC and DC power. The LOCA event peak CNV pressure is below the CNV design pressure of 10001075 psia. The LOCA peak CNV pressure and wall temperature bound the main steamline break (MSLB) and feedwater lind break (FWLB) results. The overall limiting peak CNV accident pressure is approximately 951 psia and it 986 psia, which is approximately 8 percent below the containment design pressure of 1075 psia. It results from an inadvertent reactor recirculation valve opening AOO, anticipated operational occurrence with a loss of normal AC and DC power. ThisThe peak pressure of the limiting anticipated operational occurrence is also less than the CNV design pressure of 10001075 psia. The CNV pressure for this limiting case is reduced to below 50 percent of the peak value in less than 2 hours, demonstrating adequate NPM containment heat removal. Section 5.4 discussed margin in the NPM design that is not included in the CNV design pressure rating or modeled in the containment response analyses. Design factors conservatively not credited include CNV shell stress margins, CNV cladding material atmospheric pressure acting against the CNV exterior surface and the availability of the DHRS. The containment response analysis demonstrates that the NPM design has adequate margin to design limits and that it satisfies the requriements of GDC 16 and 50 and PDC 38. © Copyright 2018 by NuScale Power, LLC 152
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 7.0 References 7.1 Source Documents 7.1.1 U.S. Code of Federal Regulations, Title 10, Part 50. 7.1.2 U.S Code of Federal Regulations, Appendix A to Part 50 - General Design Criteria for Nuclear Power Plants, (10CFR50, Appendix A). 7.1.3 U.S. Nuclear Regulatory Commission, Transient and Accident Analysis Methods, Regulatory Guide 1.203, December 2005. 7.1.4 U.S. Nuclear Regulatory Commision, Design Specific Review Standard for NuScale SMR Design, Section 6.2.1, June 2016. 7.1.5 U.S. Nuclear Regulatory Commision, Design Specific Review Standard for NuScale SMR Design, Section 6.2.1.1.A, June 2016. 7.1.6 U.S. Nuclear Regulatory Commision, Design Specific Review Standard for NuScale SMR Design, Section 6.2.1.3, June 2016. 7.1.7 U.S. Nuclear Regulatory Commision, Design Specific Review Standard for NuScale SMR Design, Section 6.2.1.4, June 2016. 7.2 Reference Documents 7.2.1 NuScale Power, LLC, LOCA Evaluation Model, TR-0516-49422, Revision 0. 7.2.2 NuScale Power, LLC, Non-LOCA Transient Analysis Methodology Report, TR-0516-49426, Revision 0. © Copyright 2018 by NuScale Power, LLC 153
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 8.0 Appendicies 8.1 Mass and Energy Input The purpose of this Appendix is to present the mass and energy release to the CNV during the limiting LOCA event (Case 2), the limiting overall peak CNV pressure event (Case 5) and the limiting secondary system release event (MSLB),. up to the time that the peak pressure is reduced to one half its value. 8.2 Heat Sink Tables The purpose of this Appendix is to present the passive heat sink characteristics credited in the containment response analysis methodology. Table 8-1 Limiting Peak Pressure Case - Mass and Energy Release Time (s) (1) Mass Release (lbm/s) Energy Release (Btu/s) 0 0 0 49.245 0 0 50.25 351.711 173140 51.255 529.189 260397 62.31 495.158 247671 95.475 411.279 236802 105.525 397.222 227323 116.58 380.903 219530 127.635 1626.91 1491710 128.64 1413.56 1311580 129.645 1182.23 1109160 130.65 967.717 909117 131.655 863.712 803803 132.66 1023.01 771943 133.665 1019.46 743749 134.67 967.35 687226 135.675 831.284 601624 136.68 716.093 524738 137.685 560.892 432894 138.69 419.776 344836 139.695 279.342 247789 140.7 188.447 170871 141.705 137.069 122905 186.93 72.4145 55850.6 348.37 45.3034 33856.7 412.53 36.9198 28001.5 © Copyright 2018 by NuScale Power, LLC 154
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Time (s) (1) Mass Release (lbm/s) Energy Release (Btu/s) 540.02 0.111389 270.432 650.05 1.6522 8387.4 650.075 -1.33437 -1593.41 760.13 -1.02407 -1227.47 870.185 11.8632 15318.7 970.235 15.5462 20038 1160.4 -0.0610871 -56.3615 1380.95 0.184891 248.364 1601.5 -0.804867 5088.77 1794.2 -0.524 -650.898 1802 -0.637231 5023.34 2014.75 0.0259352 42.1415 2170 0.390625 507.728 2180 107.388 130405 2200.05 -0.454126 -558.524 2280.25 0.151932 207.155 2400.55 -0.301595 -369.278 2420.6 -0.231089 -275.562 2440.65 46.8948 57547.2 2460.7 -0.187912 -228.765 2580 0.263031 343.004 2841.65 0.166304 218.097 3042.15 0.143518 188.538 3242.65 0.129225 169.854 3500 0.118755 3483.25 0.00 0.00 0.00 1.00 520.85 257627.45 2.00 523.17 258750.86 3.00 521.93 258164.72 4.00 519.26 256962.72 5.00 515.99 255607.71 6.00 512.44 254280.63 7.00 508.73 253062.33 8.00 504.94 251984.33 9.00 500.89 250943.23 10.00 497.07 250168.15 11.00 492.84 249319.52 12.00 488.50 248522.89 13.00 483.98 247730.73 14.00 479.49 247027.59 © Copyright 2018 by NuScale Power, LLC 155
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 15.00 475.20 246477.05 16.00 470.79 245889.66 17.00 466.32 245272.77 18.00 461.90 244650.14 19.00 457.90 244207.37 20.00 454.78 244180.29 40.00 412.85 228110.54 60.00 378.12 216874.65 61.00 377.02 215906.03 62.00 375.81 215107.74 63.00 374.48 214449.07 64.00 373.13 213733.48 65.00 371.90 212887.33 66.00 370.89 212000.58 67.00 369.82 211170.35 68.00 368.63 210506.14 69.00 367.35 209910.68 70.00 366.22 209185.02 71.00 365.31 208336.35 72.00 364.44 207525.80 73.00 363.47 206812.03 74.00 362.44 206204.10 75.00 361.43 205589.78 76.00 360.48 204939.76 77.00 1105.21 1079703.71 78.00 1263.49 1270075.68 79.00 1169.96 1206666.55 80.00 976.53 1004884.36 81.00 838.30 909863.68 82.00 735.11 697397.33 83.00 2156.32 1334963.85 84.00 1611.53 1038460.23 85.00 1230.48 794378.32 86.00 502.46 523334.05 87.00 1515.48 927023.91 88.00 231.91 254414.90 89.00 155.94 177983.24 90.00 209.84 172368.89 91.00 161.79 130981.20 92.00 144.75 115382.50 93.00 139.61 110392.72 94.00 136.23 106487.96 95.00 132.60 102460.47 © Copyright 2018 by NuScale Power, LLC 156
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 96.00 128.69 98461.93 97.00 126.62 96438.44 98.00 123.56 93419.72 99.00 120.86 90594.20 100.00 118.67 88154.41 101.00 116.65 86096.24 102.00 115.36 84829.11 103.00 114.12 83538.32 104.00 112.74 82081.88 105.00 111.91 81198.07 106.00 111.10 80460.96 107.00 110.12 79604.71 108.00 108.94 78503.95 109.00 107.37 77011.06 110.00 106.08 75843.21 111.00 105.14 75092.50 112.00 104.38 74545.22 113.00 104.15 74478.90 114.00 103.05 73560.53 115.00 102.05 72792.56 116.00 101.19 72219.92 117.00 100.41 71743.60 118.00 99.60 71236.55 119.00 98.66 70603.35 120.00 97.70 70001.60 140.00 79.37 58965.27 160.00 67.06 51663.90 180.00 58.34 46108.22 200.00 51.94 41845.43 220.00 47.36 38792.00 240.00 43.26 36013.35 260.00 37.48 32408.39 280.00 35.65 30650.56 300.00 33.86 29094.61 320.00 32.43 27834.92 340.00 30.90 26514.72 360.00 29.81 25566.75 380.00 28.61 24579.84 400.00 27.29 23548.94 420.00 26.15 22680.53 440.00 25.18 21945.98 460.00 24.11 21085.17 480.00 23.28 20464.64 © Copyright 2018 by NuScale Power, LLC 157
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 500.00 22.39 19824.76 520.00 21.45 19148.74 540.00 20.52 18497.43 560.00 19.61 17896.37 580.00 18.64 17263.95 600.00 17.69 16652.23 620.00 16.71 16050.69 640.00 15.59 15391.62 660.00 14.30 14661.37 680.00 12.98 13926.77 700.00 8.86 11910.40 720.00 7.42 11136.13 740.00 6.43 10578.58 760.00 5.72 10159.74 780.00 5.16 9842.23 800.00 4.63 9508.67 820.00 4.17 9219.58 840.00 3.77 8959.33 860.00 3.42 8737.91 880.00 3.09 8525.88 900.00 2.79 8327.20 920.00 2.56 8181.55 940.00 2.29 8002.94 960.00 2.05 7836.06 980.00 1.77 7617.34 1000.00 1.63 7541.69 1020.00 1.43 7411.43 1040.00 1.25 7284.12 1060.00 1.08 7165.44 1080.00 0.71 6883.31 1100.00 0.69 6923.14 1120.00 0.57 6829.92 1140.00 0.45 6740.14 1160.00 0.34 6655.13 1180.00 0.23 6569.41 1200.00 0.12 6484.89 1220.00 0.02 6404.77 1240.00 -0.07 6334.75 1260.00 -0.16 6270.01 1280.00 -0.23 6208.31 1300.00 -0.31 6149.76 1320.00 -0.37 6094.65 1340.00 -0.44 6042.12 © Copyright 2018 by NuScale Power, LLC 158
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 1360.00 -0.50 5993.93 1380.00 -0.55 5944.68 1400.00 -0.61 5895.22 1420.00 -0.66 5849.06 1440.00 -0.71 5805.89 1460.00 -0.75 5766.42 1480.00 -0.79 5728.05 1500.00 -0.83 5689.85 1520.00 -0.87 5652.53 1540.00 -0.91 5616.71 1560.00 -0.94 5581.06 1580.00 -0.97 5547.13 1600.00 -1.01 5513.44 1620.00 -1.04 5476.91 1640.00 -1.07 5442.10 1660.00 -1.10 5406.73 1680.00 -1.13 5375.81 1700.00 -1.15 5347.79 1720.00 -1.17 5319.46 1740.00 -1.19 5292.06 1760.00 -1.21 5265.43 1780.00 -1.23 5239.46 1787.10 -0.90 5371.96
- 1. RVVRRV opens at 500 seconds.
Table 8-2 Limiting Secondary Break Peak PressureWall Temperature Case - Mass and Energy Release Time (s)(12) Mass Release (lbm/s) Energy Release (Btu/s) 0 0 0 1.005 479.103 592441 2.01 416.448 513402 3.015 367.703 456779 4.02 324.901 408889 5.025 287.698 364725 6.03 246.597 315160 7.035 148.581 190756 12.06 156.577 198539 17.085 165.819 205905 23.115 144.182 180805 29.145 119.093 150507 35.175 98.1639 105865 © Copyright 2018 by NuScale Power, LLC 159
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Time (s)(12) Mass Release (lbm/s) Energy Release (Btu/s) 38.19 58.7877 74755.5 41.205 33.1988 42901.4 47.01 13.0776 16917.1 53.04 6.97991 9046.27 64.095 6.28984 8112.73 75.15 12.7395 16425.3 86.205 13.2017 17118.6 97.26 21.8136 28220.1 108.315 6.32603 8364.87 119.37 4.47799 6003.89 130.425 11.6693 15248.7 141.48 1.94533 2718.69 151.53 0.421951 754.803 162.585 3.36566 4553.49 173.64 3.96629 5316.12 184.695 2.78703 3807.61 195.75 1.35812 1975.04 206.805 1.43866 2075.6 217.86 3.43159 4624.47 228.915 2.97928 4039.31 239.97 2.26944 3130.48 250.02 1.47545 2115.27 261.075 1.45841 2092.53 272.13 1.53005 2181.9 283.185 0.866597 1330.24 294.24 0.691397 1103.58 305.295 0.536189 902.676 316.35 0.419932 751.601 327.405 0.344147 652.188 338.46 0.311589 608.824 348.51 0.255509 534.707 359.565 0.227776 496.142 370.62 0.287188 569.137 381.675 0.55293 909.054 392.73 0.991042 1465.49 403.785 0.853209 1280.26 414.84 0.800428 1206.54 425.895 1.06917 1547 436.95 0.887626 1300.05 © Copyright 2018 by NuScale Power, LLC 160
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Time (s)(12) Mass Release (lbm/s) Energy Release (Btu/s) 447 0.81661 1205.05 458.055 0.20107 417.002 469.11 0.394275 665.475 480.165 -0.118122 9.48294 491.22 0.308655 551.042 0.00 0.00 0.00 1.00 79.18 48243.13 2.00 79.30 48314.98 3.00 79.57 48482.36 4.00 79.92 48690.46 5.00 80.29 48914.73 6.00 80.64 49119.33 7.00 80.83 49230.89 8.00 80.91 49270.28 9.00 80.89 49252.24 10.00 80.81 49187.48 11.00 80.70 49080.36 12.00 80.59 48944.34 13.00 80.50 48782.97 14.00 80.43 48601.19 15.00 80.38 48398.72 16.00 80.37 48197.13 17.00 80.45 48031.03 18.00 80.63 47922.32 19.00 80.88 47846.57 20.00 81.14 47787.04 40.00 82.67 46764.30 60.00 81.49 45804.67 80.00 80.30 44989.66 100.00 78.89 44200.28 120.00 77.54 43524.76 140.00 76.25 42962.65 160.00 74.95 42446.83 180.00 73.72 41987.01 200.00 72.58 41572.17 220.00 72.65 41690.47 240.00 71.49 41296.20 260.00 70.43 40984.25 280.00 69.50 40786.43 300.00 68.37 40548.94 320.00 66.60 39942.51 © Copyright 2018 by NuScale Power, LLC 161
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 340.00 64.62 38980.23 360.00 64.08 38649.04 380.00 63.87 38472.63 400.00 63.87 38426.77 420.00 63.75 38342.67 440.00 63.54 38216.47 460.00 63.37 38113.27 480.00 63.22 38024.68 500.00 63.11 37955.82 520.00 63.02 37892.62 540.00 62.94 37835.79 560.00 62.87 37788.37 580.00 62.82 37745.00 600.00 62.77 37705.34 620.00 62.70 37657.63 640.00 62.66 37616.46 660.00 62.61 37577.23 680.00 62.57 37538.52 700.00 62.51 37491.14 720.00 62.47 37449.59 740.00 62.43 37409.24 760.00 62.38 37367.66 780.00 62.32 37313.38 800.00 62.23 37246.63 820.00 62.17 37187.16 840.00 62.12 37138.68 860.00 62.10 37095.76 880.00 62.10 37068.80 900.00 62.08 37029.61 920.00 62.03 36977.23 940.00 61.95 36914.79 950.00 61.85 36852.69 951.00 61.84 36846.42 952.00 61.83 36840.27 953.00 61.82 36834.32 954.00 61.81 36828.52 955.00 1352.36 1370453.47 956.00 1193.26 1214639.97 957.00 996.84 1039740.72 958.00 841.22 878708.54 959.00 677.92 705524.91 960.00 553.42 574452.22 961.00 488.95 500751.61 © Copyright 2018 by NuScale Power, LLC 162
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 962.00 378.97 386018.43 963.00 286.76 292965.95 964.00 206.23 210777.85 965.00 146.88 149539.51 966.00 104.54 106021.53 967.00 77.48 80524.71 968.00 64.94 67469.99 969.00 56.93 58992.81 970.00 51.97 53697.29 971.00 48.08 49749.34 972.00 45.23 46977.89 973.00 41.99 43648.53 974.00 39.38 41252.21 975.00 38.24 40286.01 976.00 36.20 38304.67 977.00 34.52 36582.13 978.00 32.77 35013.81 979.00 32.66 35063.81 980.00 30.51 33275.33 1000.00 7.61 16951.11 1020.00 4.87 14668.09 1040.00 3.50 13415.22 1060.00 2.36 12351.95 1080.00 1.38 11456.21 1100.00 0.53 10619.46 1120.00 -0.19 9953.30 1140.00 -0.71 9465.05 1160.00 -1.09 9093.51 1180.00 -1.49 8686.42 1200.00 -1.89 8306.51 1220.00 -2.31 7904.29 1240.00 -2.65 7592.29 1260.00 -2.97 7271.04 1280.00 -3.19 7042.75 1300.00 -3.38 6834.40 1320.00 -3.48 6721.77 1340.00 -3.67 6547.47 1360.00 -3.78 6403.45 1380.00 -3.90 6250.04 1400.00 -3.96 6129.98 1420.00 -4.00 6046.52 1440.00 -4.11 5896.39 1460.00 -4.17 5796.09 © Copyright 2018 by NuScale Power, LLC 163
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 1480.00 -4.17 5752.75 1500.00 -4.25 5623.53 1520.00 -4.26 5552.52 1540.00 -4.27 5462.45 1560.00 -4.30 5384.27 1580.00 -4.31 5317.01 1600.00 -4.31 5267.64 1620.00 -4.34 5193.43 1640.00 -4.24 5213.03 1660.00 -4.28 5114.53 1680.00 -4.30 5051.19 1700.00 -4.27 5022.07 1720.00 -4.27 4961.03 1740.00 -4.20 4963.80 1760.00 -4.10 4979.97 1780.00 -3.99 4982.59 1800.00 -3.79 5020.53 1820.00 -3.51 5109.37 1840.00 -3.34 5139.58 1860.00 -3.25 5130.42 1880.00 -3.15 5149.35 1900.00 -3.12 5103.51 1920.00 -3.11 5060.80 1940.00 -3.10 5028.42 1960.00 -3.08 4996.18 1980.00 -3.04 4966.92 2000.00 -3.09 4867.16 2020.00 -3.38 4746.53 2040.00 -3.43 4697.04 2060.00 -3.29 4710.26 2080.00 -3.16 4724.90 2100.00 -3.04 4760.70 2120.00 -2.93 4781.73 2140.00 -2.86 4788.56 2160.00 -2.82 4767.95 2180.00 -2.78 4736.15 2200.00 -2.73 4727.76 2220.00 -2.61 4763.77 2240.00 -2.55 4748.07 2260.00 -2.51 4731.84 2280.00 -2.46 4724.87 2300.00 -2.40 4733.99 2320.00 -2.34 4744.78 © Copyright 2018 by NuScale Power, LLC 164
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 2340.00 -2.24 4783.38 2360.00 -2.24 4743.72 2380.00 -2.23 4713.57 2400.00 -2.18 4719.62 2420.00 -2.34 4626.02 2440.00 -2.26 4644.15 2460.00 -2.05 4698.36 2472.90 -2.26 4601.93
- 21. Break initiated at 0 seconds.
Table 8-3 Limiting Secondary Break Peak Pressure Mass and Energy Release Time (s) (1) Mass Release (lbm/s) Energy Release (Btu/s) 0.00 0.00 0.00 1.00 429.13 529471.38 2.00 333.15 413594.14 3.00 311.07 393366.92 4.00 290.94 371550.11 5.00 264.05 339779.42 6.00 238.67 309056.90 7.00 216.91 282123.38 8.00 192.24 250588.45 9.00 118.64 154655.48 10.00 118.04 154001.57 15.00 173.00 218097.88 16.00 180.15 224434.34 17.00 184.92 227523.77 18.00 187.88 229107.05 19.00 187.54 226782.47 20.00 185.84 223894.90 25.00 159.89 196109.64 30.00 131.22 164114.01 35.00 99.41 126511.96 40.00 55.26 71015.79 45.00 34.88 44867.91 46.00 13.36 17175.87 47.00 7.15 9186.32 48.00 6.09 7825.33 49.00 5.59 7178.04 50.00 3.25 4170.70 55.00 2.81 3593.22 60.00 2.54 3252.16 © Copyright 2018 by NuScale Power, LLC 165
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 Time (s) (1) Mass Release (lbm/s) Energy Release (Btu/s) 80.00 0.73 943.37 100.00 0.57 725.24 120.00 0.48 609.39 140.00 0.49 623.51 160.00 0.35 444.30 180.00 2.14 2752.23 196.55 4.19 5420.36 Break initiated at 0 seconds. © Copyright 2018 by NuScale Power, LLC 166
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 8.2.1 Listing of Passive Heat Sinks The containment vessel shell is the only passive heat sink credited in the containment response analysis methodology. 8.2.2 Modeling of Passive Heat Sinks Table 8-4 Passive heat sinks Exposed Shell Total Passive Heat Material Thickness, Group Surface Area Volume, Total Mass, Surface Sink (Vessel steel in by Thickness ft3 lbm Area, ft2 plate) Group, ft2 ((
}}2(a),(c) 8.2.3 Thickness Groups Table 8-5 Thickness groups Material Group Thickness Range, Designation in SA-240 304L (Stainless Steel) 1 (( }}2(a),(c)
SA-240 304L (Stainless Steel) 2 ((
}}2(a),(c)
© Copyright 2018 by NuScale Power, LLC 167
Containment Response Analysis Methodology Technical Report TR-0516-49084-NP Draft Rev. 10 SA-965 FXM-19240 304L (Stainless Steel), 3 (( }}2(a),(c) SA-508 Grade 3 (Carbon Steel) 8.2.4 Properties of Passive Heat Sink Materials Table 8-6 Physical properties of passive heat sink materials Material Density, lbm/ft3 Specific Heat, Thermal Conductivity, Btu/lbm-°F Btu/hr-ft-°F SA-240 304L (Stainless 501.12 0.1137 8.6 Steel) SA-508 Grade 3 (Carbon 483.84 0.1067 23.7 Steel) SA-965 FXM-19 (Stainless 487.296 0.1142 6.4 Steel) © Copyright 2018 by NuScale Power, LLC 168
RAIO-1018-62331 : Affidavit of Jennie Wike, AF-1018-62332 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
NuScale Power, LLC AFFIDAVIT of Jennie Wike I, Jennie Wike, state as follows:
- 1. I am the Manager, Licensing of NuScale Power, LLC (NuScale), and as such, I have been specifically delegated the function of reviewing the information described in this Affidavit that NuScale seeks to have withheld from public disclosure, and am authorized to apply for its withholding on behalf of NuScale.
- 2. I am knowledgeable of the criteria and procedures used by NuScale in designating information as a trade secret, privileged, or as confidential commercial or financial information. This request to withhold information from public disclosure is driven by one or more of the following:
- a. The information requested to be withheld reveals distinguishing aspects of a process (or component, structure, tool, method, etc.) whose use by NuScale competitors, without a license from NuScale, would constitute a competitive economic disadvantage to NuScale.
- b. The information requested to be withheld consists of supporting data, including test data, relative to a process (or component, structure, tool, method, etc.), and the application of the data secures a competitive economic advantage, as described more fully in paragraph 3 of this Affidavit.
- c. Use by a competitor of the information requested to be withheld would reduce the competitor's expenditure of resources, or improve its competitive position, in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.
- d. The information requested to be withheld reveals cost or price information, production capabilities, budget levels, or commercial strategies of NuScale.
- e. The information requested to be withheld consists of patentable ideas.
- 3. Public disclosure of the information sought to be withheld is likely to cause substantial harm to NuScale's competitive position and foreclose or reduce the availability of profit-making opportunities. The accompanying Request for Additional Information response reveals distinguishing aspects about the methodology by which NuScale develops its containment response analysis.
NuScale has performed significant research and evaluation to develop a basis for this methodology and has invested significant resources, including the expenditure of a considerable sum of money. The precise financial value of the information is difficult to quantify, but it is a key element of the design basis for a NuScale plant and, therefore, has substantial value to NuScale. If the information were disclosed to the public, NuScale's competitors would have access to the information without purchasing the right to use it or having been required to undertake a similar expenditure of resources. Such disclosure would constitute a misappropriation of NuScale's intellectual property, and would deprive NuScale of the opportunity to exercise its competitive advantage to seek an adequate return on its investment. AF-1018-62332
- 4. The information sought to be withheld is in the enclosed response to NRC Request for Additional Information No. 353, eRAI 9304. The enclosure contains the designation "Proprietary" at the top of each page containing proprietary information. The information considered by NuScale to be proprietary is identified within double braces, "(( }}" in the document.
- 5. The basis for proposing that the information be withheld is that NuScale treats the information as a trade secret, privileged, or as confidential commercial or financial information. NuScale relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC§ 552(b)(4), as well as exemptions applicable to the NRC under 10 CFR §§ 2.390(a)(4) and 9.17(a)(4).
- 6. Pursuant to the provisions set forth in 10 CFR § 2.390(b )(4 ), the following is provided for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld:
- a. The information sought to be withheld is owned and has been held in confidence by NuScale.
- b. The information is of a sort customarily held in confidence by NuScale and, to the best of my knowledge and belief, consistently has been held in confidence by NuScale.
The procedure for approval of external release of such information typically requires review by the staff manager, project manager, chief technology officer or other equivalent authority, or the manager of the cognizant marketing function (or his delegate), for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside NuScale are limited to regulatory bodies, customers and potential customers and their agents, suppliers, licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or contractual agreements to maintain confidentiality.
- c. The information is being transmitted to and received by the NRC in confidence.
- d. No public disclosure of the information has been made, and it is not available in public sources. All disclosures to third parties, including any required transmittals to NRC, have been made, or must be made, pursuant to regulatory provisions or contractual agreements that provide for maintenance of the information in confidence.
- e. Public disclosure of the information is likely to cause substantial harm to the competitive position of NuScale, taking into account the value of the information to NuScale, the amount of effort and money expended by NuScale in developing the information, and the difficulty others would have in acquiring or duplicating the information. The information sought to be withheld is part of NuScale's technology that provides NuScale with a competitive advantage over other firms in the industry.
NuScale has invested significant human and financial capital in developing this technology and NuScale believes it would be difficult for others to duplicate the technology without access to the information sought to be withheld. I declare under penalty of perjury that the foregoing is true and correct. Executed on October 26, 2018. Jennie Wike AF-1018-62332}}