Final SER for NuScale TR-0516-49416 NON-Loss-of-Coolant Analysis Model, Rev 3 (Letter)
ML20181A432
Person / Time
Site: PROJ0769, NuScale
Issue date: 06/22/2020
From: Anna Bradford
NRC/NRR/DNRL
To: Rad Z
NuScale
Bavol B
Shared Package
ML20181A429 List:
References
TR-0516-49416, Rev 3
Download: ML20181A432 (3)


Text

June 22, 2020 Mr. Zackary W. Rad Director, Regulatory Affairs NuScale Power, LLC.

1100 Circle Boulevard, Suite 200 Corvallis, OR 97330

SUBJECT:

FINAL SAFETY EVALUATION FOR NUSCALE POWER, LLC TOPICAL REPORT TR-0516-49416, REVISION 3, NON-LOSS-OF-COOLANT ANALYSIS METHODOLOGY

Dear Mr. Rad:

By letter dated January 10, 2017, NuScale Power, LLC (NuScale), submitted Topical Report (TR) TR-0516-49416, Non-Loss-of-Coolant-Accident Analysis Methodology, Revision 0, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17222A827) to the U.S. Nuclear Regulatory Commission (NRC) for review and approval.

NuScale supplemented its submittal by letter dated March 7, 2017 (ADAMS Accession No. ML17066A463). By letters dated November 26, 2019, and May 27, 2020, NuScale submitted, TR-0516-49416, Revisions 2 and 3, (ADAMS Accession Nos. ML19331A516 and ML20148M391 respectively). The NRC staff has evaluated TR-0516-49416, Revision 3, and found that it is acceptable for referencing licensing applications for the NuScale small modular reactor design to the extent specified and under the conditions and limitations delineated in the enclosed safety evaluation report (SER).

The NRC staff requests that NuScale publish the applicable version(s) of the SER listed above within 30 days of receipt of this letter. The accepted version of the TR shall incorporate this letter and the enclosed SER and add -A (designated accepted) following the report identification number.

CONTACT: Bruce M. Bavol, NRR/DNRL 301-415-6715

Z. Rad If the NRC staffs criteria or regulations change, and its acceptability conclusion in the SER is invalidated, NuScale and/or the applicant referencing the SER will be expected to revise and resubmit its respective documentation; or submit justification for continued applicability of the SER without revision of the respective documentation.

After receiving the package with the -A version, the SER will be made available for public inspection through the publicly available records component of NRCs ADAMS.

If you have any questions or comments concerning this matter, please contact Bruce Bavol at 301-415-6715 or via e-mail address at Bruce.Bavol@nrc.gov.

Sincerely,

/RA/

Anna H. Bradford, Director Division of New and Renewed Licenses Office of Nuclear Reactor Regulation Docket No.52-048

Enclosures:

1.

TR-0516-49416 SER (Public)

2.

TR-0516-49416 SER (Proprietary) cc: DC NuScale Power, LLC Listserv (w/o Enclosure 2)

Pkg: ML20181A429 Letter: ML20181A432 Enclosure No. 1: ML20181A431 PUBLIC Enclosure No. 2: ML20181A430 PROP

  • via email NRR-106 OFFICE DNRL/NRLB: PM DNRL/NRLB: LA DNRL/NRLB: BC DNRL: D NAME BBavol CSmith*

MDudek*

ABradford*

DATE 06/22/2020 06/22/2020 06/23/2020 06/22/2020