June 3, 2020 Mr. Zackary W. Rad Director, Regulatory Affairs NuScale Power, LLC.
1100 Circle Boulevard, Suite 200 Corvallis, OR 97330
SUBJECT:
FINAL SAFETY EVALUATION FOR NUSCALE POWER, LLC TOPICAL REPORT TR-0716-50350, REVISION 1, ROD EJECTION ACCIDENT METHODOLOGY
Dear Mr. Rad:
By letter dated December 30, 2016, NuScale Power, LLC (NuScale), submitted Topical Report (TR) TR-0716-50350, Rod Ejection Accident Methodology, Revision 0, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16365A242) to the U.S. Nuclear Regulatory Commission (NRC) for review and approval.
By letter dated November 15, 2019, NuScale submitted, TR-0716-50350-P, Revision 1, (ADAMS Accession No. ML19319C685). The NRC staff has evaluated TR-0716-50350, Revision 1, and found that it is acceptable for referencing licensing applications for the NuScale small modular reactor design to the extent specified and under the conditions and limitations delineated in the enclosed safety evaluation report (SER).
The NRC staff requests that NuScale publish the applicable version(s) of the SER listed above within 30 days of receipt of this letter. The accepted version of the TR shall incorporate this letter and the enclosed SER and add -A (designated accepted) following the report identification number.
CONTACT: Bruce M. Bavol, NRR/DNRL 301-415-6715
Z. Rad If the NRC staffs criteria or regulations change, and its acceptability conclusion in the SER is invalidated, NuScale and/or the applicant referencing the SER will be expected to revise and resubmit its respective documentation; or submit justification for continued applicability of the SER without revision of the respective documentation.
After receiving the package with the -A version, the SER will be made available for public inspection through the publicly available records component of NRCs ADAMS.
If you have any questions or comments concerning this matter, please contact Bruce Bavol at 301-415-6715 or via e-mail address at Bruce.Bavol@nrc.gov.
Sincerely,
/RA/
Anna H. Bradford, Director Division of New and Renewed Licenses Office of Nuclear Reactor Regulation Bob Caldwell for Docket No.52-048
Enclosures:
- 1.
TR-0716-50350 SER (Public)
- 2.
TR-0716-50350 SER (Proprietary) cc: DC NuScale Power, LLC Listserv (w/o Enclosure 2)
Pkg: ML20157A220 Letter: ML20157A223 Enclosure No. 1: ML20157A221 PUBLIC Enclosure No. 2: ML20157A222 PROP
MDudek*
RCaldwell for ABradford*
DATE 06/02/2020 06/02/2020 06/02/2020 06/03/2020