Download: ML18220A980 (78)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555 October 16, 2018

SUBJECT:

OYSTER CREEK NUCLEAR GENERATING STATION - EXEMPTIONS FROM CERTAIN EMERGENCY PLANNING REQUIREMENTS AND RELATED SAFETY EVALUATION (CAC NO. MG0153; EPID L-2017-LLE-0020)

Dear Mr. Hanson:

The U.S. Nuclear Regulatory Commission (NRC) has approved the enclosed exemptions from specific requirements of Title 10 of the Code of Federal Regulations (10 CFR) Section 50.47, "Emergency plans," and Appendix E, "Emergency Planning and Preparedness for Production and Utilization Facilities," to 10 CFR Part 50. This action is in response to your application for exemptions dated August 22, 2017, as supplemented by letters dated December 6, 2017, and January 23, March 8, and March 19, 2018.

A copy of the NRC staff's safety evaluation is also enclosed. The exemptions will be forwarded to the Office of the Federal Register for publication.

Docket No. 50-219

Enclosures:

1. Exemptions
2. Safety Evaluation cc: Listserv n G. Lamb, Senior Project Manager ecial Projects and Process Branch 1vision of Operating Reactor Licensing ffice of Nuclear Reactor Regulation

ENCLOSURE 1 EXEMPTIONS

NUCLEAR REGULATORY COMMISSION Docket No. 50-219 Exelon Generation Company, LLC Oyster Creek Nuclear Generating Station Exemption I. Background.

Exelon Generation Company, LLC (Exelon or the licensee) is the holder of Renewed Facility Operating License No. DPR-16 for Oyster Creek Nuclear Generating Station (Oyster Creek). The license provides, among other things, that the facility is subject to all rules, regulations, and orders of the U.S. Nuclear Regulatory Commission (NRC) now or hereafter in effect. The facility consists of a boiling-water reactor (BWR) located in Ocean County, New Jersey.

By letter dated February 14, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18045A084), Exelon submitted a certification to the NRC that it would permanently cease power operations at Oyster Creek no later than October 31, 2018. On September 17, 2018, Exelon permanently ceased power operations at Oyster Creek.

By letter dated September 25, 2018 (ADAMS Accession No. ML18268A258), Exelon certified the permanent removal of fuel from the Oyster Creek reactor vessel.

In accordance with§ 50.82(a)(2) of Title 10 of the Code of Federal Regulations

( 10 CFR), the license for a power reactor facility no longer authorizes operation of the reactor or emplacement or retention of fuel into the reactor vessel upon the docketing of the certifications for permanent cessation of operations and permanent removal of fuel from the reactor vessel.

The facility is still authorized to possess and store irradiated (i.e., spent) nuclear fuel. Spent fuel is currently stored onsite in the Oyster Creek spent fuel pool (SFP) and a dry cask independent spent fuel storage installation (ISFSI) at the Oyster Creek facility.

During normal power reactor operations, the forced flow of water through the reactor coolant system removes heat generated by the reactor. The reactor coolant system, operating at high temperatures and pressures, transfers this heat through the steam generator tubes converting non-radioactive feedwater to steam, which then flows to the main turbine generator to produce electricity. Many of the accident scenarios postulated in the updated safety analysis reports (USARs) for operating power reactors involve failures or malfunctions of systems, which could affect the fuel in the reactor core and, in the most severe postulated accidents, would involve the release of large quantities of fission products. With the permanent cessation of operations at Oyster Creek and the permanent removal of the fuel from the reactor vessel, such accidents are no longer possible. The reactor, reactor coolant system, and supporting systems are no longer in operation and have no function related to the storage of the spent fuel.

Therefore, emergency planning (EP) provisions for postulated accidents involving failure or malfunction of the reactor, reactor coolant system, or supporting systems are no longer applicable.

The EP requirements of 10 CFR 50.47, "Emergency plans," and Appendix E to 10 CFR Part 50, "Emergency Planning and Preparedness for Production and Utilization Facilities," continue to apply to nuclear power reactors that have permanently ceased operation and have permanently removed all fuel from the reactor vessel. There are no explicit regulatory provisions distinguishing EP requirements for a power reactor that is permanently shut down and defueled from those for a reactor that is authorized to operate. To reduce or eliminate EP requirements that are no longer necessary due to the decommissioning status of the facility, Exelon must obtain exemptions from those EP regulations. Only then can Exelon modify the Oyster Creek emergency plan to reflect the reduced risk associated with the permanently shutdown and defueled condition of Oyster Creek.

2

II. Request/Action.

By letter dated August 22, 2017 (ADAMS Accession No. ML17234A082), Exelon requested exemptions from certain EP requirements of 10 CFR Part 50 for Oyster Creek.

Specifically, Exelon requested exemptions from certain planning standards in 10 CFR 50.47(b) regarding onsite and offsite radiological emergency preparedness plans for nuclear power reactors, from certain requirements in 10 CFR 50.47(c)(2) for establishment of plume exposure and ingestion pathway emergency planning zones for nuclear power reactors; and from certain requirements in 10 CFR Part 50, Appendix E,Section IV, which establishes the elements that make up the content of emergency plans. In letters dated December 6, 2017, and January 23, March 8, and March 19, 2018 (ADAMS Accession Nos. ML17340A708, ML18023A138, ML18067A087, and ML18078A146, respectively), Exelon provided supplemental information and responses to the NRC staff's requests for additional information concerning the proposed exemptions.

The information provided by Exelon included justifications for each exemption requested.

The exemptions requested by Exelon would eliminate the requirements to maintain formal offsite radiological emergency preparedness plans reviewed by the Federal Emergency Management Agency (FEMA) under the requirements of 44 CFR Part 350 and would reduce the scope of onsite EP activities at Oyster Creek. The licensee stated that the application of all of the standards and requirements in 10 CFR 50.47(b), 10 CFR 50.47(c), and 10 CFR Part 50, Appendix E is not needed for adequate emergency response capability, based on the substantially lower onsite and offsite radiological consequences of accidents still possible at the permanently shutdown and defueled facility, as compared to an operating facility. If offsite protective actions were needed for a highly unlikely beyond-design-basis accident that could challenge the safe storage of spent fuel at Oyster Creek, provisions exist for offsite agencies to take protective actions using a comprehensive emergency management plan (CEMP) under the 3

National Preparedness System to protect the health and safety of the public. A CEMP in this context, also referred to as an emergency operations plan, is addressed in FEMA's Comprehensive Preparedness Guide 101, "Developing and Maintaining Emergency Operations Plans," which is publicly available at http://www.fema.gov/pdf/about/divisions/npd/CPG 101 V2.pdf. Comprehensive Preparedness Guide 101 is the foundation for State, territorial, Tribal, and local EP in the United States. It promotes a common understanding of the fundamentals of risk-informed planning and decision-making and helps planners at all levels of government in their efforts to develop and maintain viable, all-hazards, all-threats emergency plans. An emergency operations plan is flexible enough for use in all emergencies. It describes how people and property will be protected; details who is responsible for carrying out specific actions; identifies the personnel, equipment, facilities, supplies and other resources available; and outlines how all actions will be coordinated. A CEMP is often referred to as a synonym for "all-hazards planning."

Ill. Discussion.

In accordance with 10 CFR 50.12, "Specific exemptions," the Commission may, upon application by any interested person or upon its own initiative, grant exemptions from the requirements of 10 CFR Part 50 when: (1) the exemptions are authorized by law, will not present an undue risk to public health and safety, and are consistent with the common defense and security; and (2) any of the special circumstances listed in 10 CFR 50.12(a)(2) are present.

These special circumstances include, among other things, that the application of the regulation in the particular circumstances would not serve the underlying purpose of the rule or is not necessary to achieve the underlying purpose of the rule.

As noted previously, the EP regulations contained in 10 CFR 50.47(b) and Appendix E to 1 O CFR Part 50 apply to both operating and shutdown power reactors. The NRC has 4

consistently acknowledged that the risk of an offsite radiological release at a power reactor that has permanently ceased operations and permanently removed fuel from the reactor vessel is significantly lower, and the types of possible accidents are significantly fewer, than at an operating power reactor. However, the EP regulations do not recognize that once a power reactor permanently ceases operation, the risk of a large radiological release from credible emergency accident scenarios is significantly reduced. The reduced risk for any significant offsite radiological release is based on two factors. One factor is the elimination of accidents applicable only to an operating power reactor, resulting in fewer credible accident scenarios.

The second factor is the reduced short"'.'lived radionuclide inventory and decay heat production due to radioactive decay. Due to the permanently defueled status of the reactor, no new spent fuel will be added to the SFP and the radionuclides in the current spent fuel will continue to decay as the spent fuel ages. The irradiated fuel will produce less heat due to radioactive decay, increasing the available time to mitigate a loss of water inventory from the SFP. The NRC's NUREG/CR-6451, "A Safety and Regulatory Assessment of Generic BWR [Boiling Water Reactor] and PWR [Pressurized Water Reactor] Permanently Shutdown Nuclear Power Plants,"

dated August 1997 (ADAMS Accession No. ML082260098), and the NRC's NUREG-1738, "Technical Study of Spent Fuel Pool Accident Risk at Decommissioning Nuclear Power Plants,"

dated February 2001 (ADAMS Accession No. ML010430066), confirmed that for permanently shutdown and defueled power reactors that are bounded by the assumptions and conditions in the report, the risk of offsite radiological release is significantly less than for an operating power reactor.

In the past, EP exemptions similar to those requested for Oyster Creek, have been granted to permanently shutdown and defueled power reactor licensees. However, the exemptions did not relieve the licensees of all EP requirements. Rather, the exemptions allowed the licensees to modify their emergency plans commensurate with the credible site-specific risks that were consistent with a permanently shutdown and defueled status.

5

Specifically, the NRC's approval of these prior exemptions was based on the licensee's demonstration that: ( 1) the radiological consequences of design-basis accidents would not exceed the limits of the U.S. Environmental Protection Agency's (EPA) early phase Protective Action Guides (PAGs) of one roentgen equivalent man (rem) at the exclusion area boundary; and (2) in the highly unlikely event of a beyond-design-basis accident resulting in a loss of all modes of heat transfer from the fuel stored in the SFP, there is sufficient time to initiate appropriate mitigating actions, and if needed, for offsite authorities to implement offsite protective actions using a CEMP approach to protect the health and safety of the public.

With respect to design-basis accidents at Oyster Creek, the licensee provided an analysis demonstrating that 12 months (365 days) following permanent cessation of power operations, the radiological consequences of the only remaining design-basis accident with potential for offsite radiological release (the fuel handling accident in the Auxiliary Building, where the SFP is located) will not exceed the limits of the EPA PAGs at the exclusion area boundary.

With respect to beyond-design-basis accidents at Oyster Creek, the licensee analyzed a drain down of the SFP water that would effectively impede any decay heat removal. The analysis demonstrates that at 12 months (365 days) after permanent cessation of power operations, there would be 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> after the assemblies have been uncovered until the limiting fuel assembly (for decay heat and adiabatic heatup analysis) reaches 900 degrees Celsius

( ° C), the temperature used to assess the potential onset of fission product release. The analysis conservatively assumed that the heat up time starts when the SFP has been completely drained, although it is likely that site personnel will start to respond to an incident when drain down starts. The analysis also does not consider the period of time from the initiating event causing loss of SFP water inventory until cooling is lost.

The NRC reviewed the licensee's justification for the requested exemptions against the criteria in 1 O CFR 50.12(a) and determined, as described below, that the criteria in 6

10 CFR 50.12(a) will be met, and that the exemptions should be granted 365 days after Oyster Creek has permanently defueled. An assessment of the Exelon EP exemptions is described in SECY-18-0062, "Request by the Exelon Generation Company, LLC for Exemptions from Certain Emergency Planning Requirements for the Oyster Creek Nuclear Generating Station,"

dated May 31, 2018 (ADAMS Accession No. ML180308340). The Commission approved the NRC staff's recommendation to grant the exemptions in the staff requirements memorandum to SECY-18-0062, dated July 17, 2018 (ADAMS Accession No. ML18198A449). Descriptions of the specific exemptions requested by Exelon and the NRC staff's basis for granting each exemption are provided in SECY-18-0062. The NRC staff's detailed review and technical basis for the approval of the specific EP exemptions requested by Exelon, are provided in the NRC staff's safety evaluation associated with this exemption (ADAMS Accession No. ML18220A980).

A.

The Exemption is Authorized by Law.

The licensee has proposed exemptions from certain EP requirements in 10 CFR 50.47(b), 10 CFR 50.47(c)(2), and 10 CFR 50, Appendix E,Section IV, that would allow Exelon to revise the Oyster Creek Emergency Plan to reflect the permanently shutdown and defueled condition of the facility. As stated above, in accordance with 10 CFR 50.12, the Commission may, upon application by any interested person or upon its own initiative, grant exemptions from the requirements of 10 CFR Part 50. The NRC staff has determined that granting of the licensee's proposed exemptions will not result in a violation of the Atomic Energy Act of 1954, as amended, or the NRC's regulations. Therefore, the exemptions are authorized bylaw.

B.

The Exemption Presents no Undue Risk to Public Health and Safety.

As stated previously, Exelon provided an analysis that show that the radiological consequences of design-basis accidents will not exceed the limits of the EPA early phase PAGs 7

at the exclusion area boundary. Therefore, formal offsite radiological emergency preparedness plans required under 10 CFR Part 50 will no longer be needed for protection of the public beyond the exclusion area boundary, based on the radiological consequences of design-basis accidents still possible at Oyster Creek 365 days after the plant has permanently ceased power operations.

Although highly unlikely, there is one postulated beyond-design-basis accident that might result in significant offsite radiological releases. However, NUREG-1738 confirms that the risk of beyond-design-basis accidents is greatly reduced at permanently shutdown and defueled reactors. The NRC staff's analyses in NUREG-1738 conclude that the event sequences important to risk at permanently shutdown and defueled power reactors are limited to large earthquakes and cask drop events. For EP assessments, this is an important difference relative to operating power reactors, where typically a large number of different sequences make significant contributions to risk. As described in NUREG-1738, relaxation of offsite EP requirements in 10 CFR Part 50 beyond a few months after shutdown resulted in only a small change in risk. The report further concludes that the change in risk due to relaxation of offsite EP requirements is small because the overall risk is low, and because even under current EP requirements for operating power reactors, EP was judged to have marginal impact on evacuation effectiveness for the severe earthquakes that dominate SFP risk. All other sequences including cask drops (for which offsite radiological emergency preparedness plans are expected to be more effective) are too low in likelihood to have a significant impact on risk.

Therefore, granting exemptions to eliminate the requirements of 10 CFR Part 50 to maintain offsite radiological emergency preparedness plans and to reduce the scope of onsite EP activities will not present an undue risk to the public health and safety.

8

C.

The Exemption is Consistent with the Common Defense and Security.

The requested exemptions only involve EP requirements under 10 CFR Part 50 and will allow Exelon to revise the Oyster Creek Emergency Plan to reflect the permanently shutdown and defueled condition of the facility. Physical security measures at Oyster Creek are not affected by the requested EP exemptions. The discontinuation of formal offsite radiological emergency preparedness plans and the reduction in scope of the onsite EP activities at Oyster Creek will not adversely affect Exelon's ability to physically secure the site or protect special nuclear material. Therefore, the proposed exemptions are consistent with common defense and security.

D.

Special Circumstances Special circumstances, in accordance with 10 CFR 50.12(a)(2)(ii), are present whenever application of the regulation in the particular circumstances is not necessary to achieve the underlying purpose of the rule. The underlying purpose of 10 CFR 50.47(b),

10 CFR 50.47(c)(2), and 10 CFR Part 50, Appendix E,Section IV, is to provide reasonable assurance that adequate protective measures can and will be taken in the event of a radiological emergency, to establish plume exposure and ingestion pathway emergency planning zones for nuclear power plants, and to ensure that licensees maintain effective offsite and onsite radiological emergency preparedness plans. The standards and requirements in these regulations were developed by considering the risks associated with operation of a power reactor at its licensed full-power level. These risks include the potential for a reactor accident with offsite radiological dose consequences.

As discussed previously in Section Ill, because Oyster Creek will be permanently shut down and defueled, there will no longer be a risk of a significant offsite radiological release from a design-basis accident exceeding EPA early phase PAG at the exclusion area boundary and the risk of a significant offsite radiological release from a beyond-design-basis accident is 9

greatly reduced when compared to an operating power reactor. The NRC staff has confirmed the reduced risks at Oyster Creek by comparing the generic risk assumptions in the analyses in NUREG-1738 to site-specific conditions at Oyster Creek and determined that the risk values in NUREG-1738 bound the risks presented at Oyster Creek. As indicated by the results of the research conducted for NUREG-1738, and more recently for NUREG-2161, "Consequence Study of a Beyond-Design-Basis Earthquake Affecting the Spent Fuel Pool for a U.S. Mark I Boiling Water Reactor," dated September 2014 (ADAMS Accession No. ML14255A365), while other consequences can be extensive, accidents from SFPs with significant decay time have little potential to cause offsite early fatalities, even if the formal offsite radiological EP requirements were relaxed. The licensee's analysis of a beyond-design-basis accident involving a complete loss of SFP water inventory, based on an adiabatic heatup analysis of the limiting fuel assembly for decay heat, shows that within 12 months (365 days) after permanent cessation of power operations, the time for the limiting fuel assembly to reach 900 °C is at least 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> after the assemblies have been uncovered assuming a loss of all cooling means.

The only analyzed beyond-design-basis accident scenario that progresses to a condition where a significant offsite release might occur, involves the highly unlikely event where the SFP drains in such a way that all modes of cooling or heat transfer are assumed to be unavailable, which is referred to as an adiabatic heatup of the spent fuel. The licensee's analysis of this beyond-design-basis accident shows that within 12 months (365 days) after permanent cessation of power operations, at least 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> would be available between the time that all cooling means are lost to the fuel (at which time adiabatic heatup is conservatively assumed to

-begin), until the fuel cladding reaches a temperature of 1652 degrees Fahrenheit (900 °C),

which is the temperature associated with rapid cladding oxidation and the potential for a significant radiological release. This analysis conservatively does not include the period of time from the initiating event causing a loss of SFP water inventory until all cooling means are lost.

10

The NRC staff has verified Exelon's analyses and its calculations. The analyses provide reasonable assurance that in granting the requested exemptions to Exelon, there is no design-basis accident that will result in an offsite radiological release exceeding the EPA early phase PAGs at the exclusion area boundary. In the highly unlikely event of a beyond-design-basis accident affecting the SFP that results in a complete loss of heat removal via all modes of heat transfer, there will be over 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> available before an offsite release might occur and, therefore, at least 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> to initiate appropriate mitigating actions to restore a means of heat removal to the spent fuel. If a radiological release were projected to occur under this highly unlikely scenario, a minimum of 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> is considered sufficient time for offsite authorities to implement protective actions using a CEMP approach to protect the health and safety of the public.

Exemptions from the offsite EP requirements in 10 CFR Part 50 have previously been approved by the NRC when the site-specific analyses show that at least 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> is available following a loss of SFP coolant inventory accident with no air cooling ( or other methods of removing decay heat) until cladding of the hottest fuel assembly reaches the rapid oxidation temperature. The NRC staff concluded in its previously granted exemptions, as it does with Exelon's requested EP exemptions, that if a minimum of 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> is available to initiate mitigative actions consistent with plant conditions, or if needed, for offsite authorities to implement protective actions using a CEMP approach, then formal offsite radiological emergency preparedness plans, required under 10 CFR Part 50, are not necessary at permanently shutdown and defueled facilities.

Additionally, Oyster Creek committed to maintaining SFP makeup strategies in its letters to the NRC dated March 8 and 19, 2018. The multiple strategies for providing makeup to the SFP include: using existing plant systems for inventory makeup; an internal strategy that relies on the fire protection system with redundant pumps (one diesel-driven and electric motor-driven); and onsite diesel fire truck that can take suction from the Barnegat Bay. These 11

strategies will continue to be required as condition 2.C.(8), "Mitigation Strategy License Condition," of renewed facility operating license DPR-16 for Oyster Creek. Considering the very low probability of beyond-design-basis accidents affecting the SFP, these diverse strategies provide multiple methods to obtain additional makeup or spray to the SFP before the onset of any postulated offsite radiological release.

For all of the reasons stated above, the NRC staff finds that the licensee's requested exemptions meet the underlying purpose of all of the standards in 10 CFR 50.47(b ), and requirements in 10 CFR 50.47(c)(2) and 10 CFR Part 50, Appendix E, and satisfy the special circumstances provision in 10 CFR 50.12(a)(2)(ii) in view of the greatly reduced risk of offsite radiological consequences associated with the permanently shutdown and defueled state of the Oyster Creek facility 12 months (365 days) after permanent cessation of power operations.

The NRC staff has concluded that the exemptions being granted by this action will maintain an acceptable level of emergency preparedness at Oyster Creek and, if needed, that there is reasonable assurance that adequate offsite protective measures can and will be taken by State and local government agencies using a CEMP approach in the unlikely event of a radiological emergency at Oyster Creek. Since the underlying purposes of the rules, as exempted, would continue to be achieved, even with the elimination of the requirements under 10 CFR Part 50 to maintain formal offsite radiological emergency preparedness plans and the reduction in the scope of the onsite emergency planning activities at Oyster Creek, the special circumstances required by 10 CFR 50.12(a)(2)(ii) exist.

E.

Environmental Considerations In accordance with 10 CFR 51.31 (a), the Commission has determined that the granting of this exemption will not have a significant effect on the quality of the human environment as discussed in the NRC staff's Finding of No Significant Impact and associated Environmental Assessment published in the Federal Register on August 13, 2018 (83 FR 40092).

12

IV. Conclusions.

Accordingly, the Commission has determined that, pursuant to 10 CFR 50.12, Exelon's request for exemptions from certain EP requirements in 10 CFR 50.47(b), 10 CFR 50.47(c)(2),

and 10 CFR Part 50, Appendix E,Section IV, and as summarized in Enclosure 2 to SECY-18-0062, are authorized by law, will not present an undue risk to the public health and safety, and are consistent with the common defense and security. Also, special circumstances are present. Therefore, the Commission hereby grants Exelon's exemptions from certain EP requirements in 10 CFR 50.47(b), 10 CFR 50.47(c)(2), and 10 CFR Part 50, Appendix E,Section IV, as discussed and evaluated in detail in the NRC staffs safety evaluation associated with this exemption. The exemptions are effective as of 12 months (365 days) after permanent cessation of power operations.

Dated at Rockville, Maryland, this 16th day of October, 2018.

For the Nuclear Regulatory Commission.

Kathryn M. Brock, Deputy Director, Division of Operating Reactor Licensing, Office of Nuclear Reactor Regulation.

13

ENCL0SURE2 SAFETY EVALUATION RELATED TO EXELON GENERATION COMPANY, LLC OYSTER CREEK NUCLEAR GENERATING STATION REQUEST FOR EXEMPTIONS FROM PORTIONS OF 10 CFR 50.47 AND 10 CFR PART 50, APPENDIX E

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO REQUEST FOR EXEMPTIONS FROM PORTIONS OF 10 CFR 50.47 AND 10 CFR PART 50, APPENDIX E EXELON GENERATION COMPANY, LLC OYSTER CREEK NUCLEAR GENERATING STATION DOCKET NO. 50-219

1.0 INTRODUCTION

Oyster Creek Nuclear Generating Station (Oyster Creek) is a power reactor located near the Atlantic Ocean within the State of New Jersey. The facility site, approximately 152 acres, is in Lacey and Ocean Townships, Ocean County. The Oyster Creek site is about 2 miles inland from the shore of Barnegat Bay and 7 miles west northwest of Barnegat Light on the Atlantic shorefront. The site is approximately 9 miles south of Toms River, New Jersey, about 50 miles east of Philadelphia, Pennsylvania, and 60 miles south of Newark, New Jersey. Exelon Generation Company, LLC (Exelon, the licensee) is the holder of the Renewed Facility Operating License No. DPR-16, issued pursuant to the Atomic Energy Act of 1954, as amended, and Part 50, "Domestic Licensing of Production and Utilization Facilities," of Title 10 of the Code of Federal Regulations ( 10 CFR), authorizing the licensee to possess and store spent nuclear fuel and greater-than-Class C radioactive waste.

By letter dated January 7, 2011 (Reference 1 ), pursuant to 10 CFR 50.82(a)(1 )(i), Exelon provided formal notification to the U.S. Nuclear Regulatory Commission (NRC) that it planned to permanently cease operations at Oyster Creek no later than December 31, 2019. By letter dated February 14, 2018 (Reference 2), Exelon subsequently notified the NRC of its plans to permanently cease operations at Oyster Creek no later than October 31, 2018. Exelon permanently ceased power operations at Oyster Creek on September 17, 2018. By letter dated September 25, 2018 (Reference 52), Exelon certified the permanent removal of fuel from the Oyster Creek reactor vessel. Since the docketing of the certifications for permanent cessation of operations and permanent removal of fuel from the reactor vessel, as specified in 10 CFR 50.82(a)(2), has been completed, the 10 CFR Part 50 license for Oyster Creek no longer authorizes operation of the reactor or emplacement or retention of fuel into the reactor vessel. Spent fuel is currently stored onsite in the Oyster Creek spent fuel pool (SFP) and a dry cask independent spent fuel storage installation (ISFSI) at the Oyster Creek facility.

By letter dated August 22, 2017 (Reference 3), and as supplemented by letters dated December 6, 2017, and January 23, March 8, and March 19, 2018 (References 4, 5, 6, and 7, respectively), Exelon requested exemptions from specific emergency preparedness (EP) requirements of 10 CFR Part 50 for Oyster Creek. Specifically, Exelon requested exemptions from certain planning standards in 10 CFR 50.47(b) regarding onsite and offsite radiological emergency preparedness (REP) plans for nuclear power reactors, from certain requirements in 10 CFR 50.47(c)(2) for establishment of plume exposure pathway and ingestion pathway emergency planning zones (EPZs) for nuclear power reactors, and from certain requirements in 10 CFR Part 50, Appendix E,Section IV, "Content of Emergency Plans," which establishes the elements that make up the content of emergency plans. Exelon's requested exemptions would eliminate the requirements to maintain formal offsite1 REP plans in accordance with 44 CFR Part 350, "Review and Approval of State and Local Radiological Emergency Plans and Preparedness," and would reduce the scope of the onsite emergency planning activities at Oyster Creek, based on the reduced risks of an offsite radiological release at Oyster Creek 12 months (365 days) after permanent cessation of power operations. The exemptions will maintain the requirements for an onsite radiological emergency plan and will continue to ensure the capability to communicate and coordinate with offsite response authorities. The NRC staff found the application complete, and the licensee's associated technical justification provides a basis for the Commission's consideration of the requested exemption.

In accordance with 10 CFR 50.12, "Specific exemptions," the licensee stated that this exemption request: ( 1) is authorized by law; (2) will not present an undue risk to the public health and safety; (3) is consistent with the common defense and security, and (4) meets the requirement for special circumstances in 10 CFR 50.12(a)(2).

2.0 DISCUSSION The regulations governing EP for nuclear power reactors are set forth in 10 CFR 50.47, 10 CFR 50.54(q), (s), and (t), and Appendix E to 10 CFR Part 50. Every nuclear power reactor licensee must establish and maintain emergency plans and preparedness in accordance with these regulations. The EP regulations for a nuclear power reactor include standards for both onsite and offsite emergency response plans. These regulations and the planning basis for EP are based upon an anticipated prompt response to a wide spectrum of events. However, for a nuclear power reactor that is no longer operating and is in decommissioning, the spectrum of accidents that can have significant offsite consequences is greatly reduced. At a decommissioning nuclear power reactor site, the only accident scenario that might lead to a significant radiological release is a highly unlikely, beyond-design-basis event resulting in a potential spent fuel zirconium cladding fire. This event involves a postulated major loss of water inventory from the SFP resulting in a loss of cooling to the spent fuel, where preplanned SFP mitigation measures were unsuccessful, generating a significant heat-up of the spent fuel to the point where substantial zirconium cladding oxidation and fuel damage can occur. The amount of decay heat present in irradiated fuel in the SFP is directly related to the amount of time that has passed after the reactor is shut down. As such, the potential for the conditions needed for a zirconium cladding fire to occur continues to decrease as a function of the time since the reactor was permanently shut down. However, current regulations do not reflect that: (1) considerably more time is available during decommissioning to respond to a postulated zirconium cladding fire incident than is available for many postulated operating power reactor accidents, and (2) comprehensive SFP mitigation measures and on-shift staff remain in place following the permanent cessation of power operations.

1 The offsite standards are reproduced in the Federal Emergency Management Agency (FEMA) regulations at 44 CFR Part 350.5 and are based on the standards established by the Commission in 10 CFR 50.47.

Since there are no explicit regulatory provisions distinguishing EP requirements for a nuclear power reactor that has permanently ceased operating from those for an operating nuclear power reactor, licensees transitioning to or already in the decommissioning phase usually seek to establish a level of EP commensurate with the risk of a radiological emergency at a decommissioning site. Exemptions from certain EP requirements are typically requested early in the decommissioning process. The NRC reviews each request on a case-by-case basis and grants exemptions only after conducting a thorough analysis of each request. Historically, given the significant reduction in radiological risk for a decommissioning site, the NRC has approved

  • exemptions from EP requirements based on site-specific evaluations and the objectives of the regulations. Between 1987 and 1999, the NRC issued exemptions from EP requirements for 10 licensees in decommissioning. More recently, exemptions from EP requirements during decommissioning have been granted for the Kewaunee Power Station, Crystal River Unit 3 Nuclear Generating Plant, San Onofre Nuclear Generating Station, Units 2 and 3, Vermont Yankee Nuclear Power Station, and Fort Calhoun Station, Unit 1 (References 8, 9, 10, 11, and 12, respectively).

Previously granted exemptions from EP regulations reduced the requirements for decommissioning power reactors to those consistent with these standards:

(1) 10 CFR 50.47(d),2 which states the requirements for a license authorizing only fuel loading and low power testing; and (2) 10 CFR 72.32(a),3 which establishes the information required in an emergency plan for an ISFSI. Examples of previously granted exemptions from EP regulations for decommissioning power reactors include: setting the highest emergency classification level as an "Alert"; extending the timing requirements for notification of offsite authorities; requiring only onsite exercises with the opportunity for offsite response organization (ORO) participation, and only maintaining arrangements for OROs (i.e., law enforcement, fire and medical services) that might support the licensee's response to onsite emergencies.4 The EP exemptions also relieve the licensee from the requirement to maintain formal offsite REP plans, including the 10-mile plume exposure pathway and 50-mile ingestion pathway EPZs.

Licensees that have been granted EP exemptions must continue to maintain an onsite emergency plan addressing the classification of an emergency, notification of emergencies to licensee personnel and offsite authorities, and coordination with designated offsite government officials following an event declaration.

2 10 CFR 50.47(d) states, in part, "Notwithstanding the requirements of paragraphs (a) and (b) of this section, and except as specified by this paragraph, no NRC or FEMA review, findings, or determinations concerning the state of offsite emergency preparedness or the adequacy of and capability to implement State and local or utility offsite emergency plans are required prior to issuance of an operating license authorizing only fuel loading or low power testing and training (up to 5 percent of the rated thermal power)."

3The Final Rule for 10 CFR Part 72, "Emergency Planning Licensing Requirements for Independent Spent Fuel Storage Facilities (ISFSI) and Monitored Retrievable Storage Facilities (MRS)," (60 Federal Register (FR) 32430, June 22, 1995), states that "the postulated worst-case accident involving an ISFSI has insignificant consequences to public health and safety. Therefore, the final requirements to be imposed on most ISFSI licensees reflect this fact, and do not mandate formal offsite components to their onsite emergency plans." It also states, "based on the potential inventory of radioactive material, potential driving forces for distributing that amount of radioactive material, and the probability of the initiation of these events, the Commission concludes that the offsite consequences of potential accidents at an ISFSI or a MRS would not warrant establishing Emergency Planning Zones."

4 Requirements for licensees to maintain agreements for fire-fighting and local law enforcement services exist outside of EP (i.e., the requirement for licensees to maintain a fire protection plan in 10 CFR 50.48, "Fire protection," and physical security requirements in 10 CFR Part 73).

In evaluating the EP exemptions requested by Exelon, specifically in relation to relieving the licensee from the requirement to maintain formal offsite REP plans, the NRC staff considered the conclusions from recent SFP studies completed since the publication of NUREG-1738, "Technical Study of Spent Fuel Pool Accident Risk at Decommissioning Nuclear Power Plants,"

February 2001 (Reference 13), which served as the technical basis for SECY-01-0100, "Policy Issues Related to Safeguards, Insurance, and Emergency Preparedness Regulations at Decommissioning Nuclear Power Plants Storing Fuel in Spent Fuel Pools" (Reference 14). In addition, the NRC staff considered enhancements put into place as a result of the events of September 11, 2001, and the March 11, 2011, accident at the Fukushima Dai-ichi site. This information helped to inform staff positions that only a highly unlikely, beyond-design-basis event (e.g., extreme earthquake or large aircraft impact) would cause sufficient structural damage to the SFP structure resulting in a rapid SFP water drain down and potential zirconium cladding fire. In addition, there would be a significant amount of time between the initiating event and the possible onset of conditions that could result in a zirconium cladding fire. This time provides a substantial opportunity for event mitigation. Licensees are required to maintain effective strategies, sufficient resources, and adequately trained personnel to mitigate such an event. If State or local governmental officials determine that offsite protective actions are warranted, then sufficient time and capability would be available for OROs to implement these measures using a comprehensive, or "all-hazards," emergency management plan (CEMP) approach.5 Spent Fuel Pool Study Considerations Since the permanent removal of spent fuel from the reactor vessel, the principal radiological risks are associated with the storage of spent fuel onsite. Generally, a few months after the reactor has been permanently shut down, there are no possible design-basis events that could result in a radiological release exceeding the U.S. Environmental Protection Agency (EPA),

EPA-400-R-92-001, "Manual of Protective Action Guides and Protective Actions for Nuclear Incidents," October 1991 (Reference 16), early phase protective action guide (PAG) limits at the exclusion area boundary (EAB). The only potential accident that might lead to a significant radiological release at a decommissioning reactor is a zirconium cladding fire, which is a postulated, but highly unlikely, beyond-design-basis event scenario that involves a major loss of water inventory from the SFP, resulting in a significant heat-up of the spent fuel due to the loss of all cooling, and culminating in substantial zirconium cladding oxidation and fuel damage. The significance of spent fuel heat-up scenarios that might result in a zirconium cladding fire depends on the decay heat of the irradiated fuel stored in the SFP. The amount of decay heat in the spent fuel is directly related to the amount of time since the reactor permanently ceased operations. Therefore, the probability of a zirconium cladding fire scenario continues to decrease as a function of the time that the decommissioning reactor has been permanently shut down.

The NRC staff assessed the risk of an SFP accident at decommissioning nuclear power plants in the late 1990s to support development of a risk-informed technical basis for review of exemption requests and a regulatory framework for integrated rulemaking. The NRC's NUREG/CR-6451, "A Safety and Regulatory Assessment of Generic BWR [Boiling Water Reactor] and PWR [Pressurized Water Reactor] Permanently Shutdown Nuclear Power Plants,"

5 A CEMP in this context, also referred to as an emergency operations plan, is addressed in the FEMA's Comprehensive Preparedness Guide 101, "Developing and Maintaining Emergency Operations Plans," Version 2.0, November 2012 (Reference 15).

August 1997 (Reference 17), and NUREG-1738 confirmed that for permanently shutdown and defueled power reactors that are bounded by the assumptions and conditions in the report, the risk of offsite radiological release is significantly less than for an operating power reactor.

The NRC staff's assessment, published in NUREG-1738, conservatively assumed that if the water level in the SFP did drop below the top of the spent fuel, a zirconium cladding fire involving all of the spent fuel would occur, and thereby bounded those conditions associated with air cooling of the fuel (including partial drain-down scenarios) and fire propagation. The study used simplified and sometimes bounding assumptions and models to characterize the likelihood and consequences of beyond-design-basis SFP accidents. Even with these conservative assumptions, the study found the risk of an SFP fire to be low and well within the Commission's safety goals. The amount of time available (after complete fuel uncovery) before onset of a zirconium cladding fire also depends on various factors, including decay heat rate, fuel burnup, fuel storage configuration, building ventilation rates and air flow paths, and fuel cladding oxidation rates. Although NUREG-1738 did not completely rule out the possibility of a zirconium fire, it did demonstrate that storage of spent fuel in a high density configuration in SFPs is safe, and that the risk of accidental release of a significant amount of radioactive material to the environment is low.

After the events of September 11, 2001, Sandia National Laboratories conducted studies (collectively, referred to as the "Sandia studies"), which considered spent fuel loading patterns and other aspects for a SFP at both a pressurized water reactor and a boiling water reactor, including the role that the circulation of air plays in the cooling of spent fuel. These studies are not publicly available because they contain security-related information. The Sandia studies indicated that there is a significant amount of time between the initiating event (i.e., the event that causes the SFP water level to drop) and the spent fuel assemblies becoming partially or completely uncovered. In addition, the Sandia studies indicated that for those hypothetical conditions where air cooling may not be effective in preventing a zirconium cladding fire, there is a significant am_ount of time between the spent fuel becoming uncovered and the possible onset of such a zirconium cladding fire, thereby providing a substantial opportunity for event mitigation. The Sandia studies, which account for relevant heat transfer and fluid flow mechanisms, also indicated that air-cooling of spent fuel could be sufficient to prevent SFP zirconium fires at a point much earlier following fuel offload from the reactor than previously considered (e.g., in NUREG-1738).

In NUREG-2161, "Consequence Study of a Beyond-Design-Basis Earthquake Affecting the Spent Fuel Pool for a U.S. Mark I Boiling Water Reactor," September 2014 (Reference 18), the NRC evaluated the potential benefits of strategies required in 10 CFR 50.54(hh)(2) to maintain or restore SFP cooling capabilities under the circumstances associated with the loss of large areas of the plant due to explosions or fire. The study results for the analyzed severe earthquake at the reference plant are consistent with past studies' conclusions that SFPs are robust structures and likely to withstand severe earthquakes without leaking. The study showed that the likelihood of a radiological release from the spent fuel, after the analyzed severe earthquake at the reference plant, to be about one time in 10 million years or lower. As explained in NUREG-2161, successful implementation of mitigation strategies significantly reduces the likelihood of a release from the SFP in the event of a loss of cooling water.

In 2014, the NRC documented a regulatory analysis of expediting the transfer of spent fuel assemblies in COMSECY-13-0030, "Staff Evaluation and Recommendation for Japan Lessons-Learned Tier 3 Issue on Expedited Transfer of Spent Fuel" (Reference 19). The NRC staff concluded that SFPs are robust structures with large safety margins and recommended to the Commission that possible regulatory actions to require the expedited transfer of spent fuel from SFPs to dry cask storage were not warranted. The Commission subsequently approved the staff's recommendation in the Staff Requirements Memorandum to COMSECY-13-0030 (Reference 20).

To inform its current integrated decommissioning rulemaking effort, the NRC staff conducted an applied research study, as documented in a memorandum "Transmittal of Reports to Inform Decommissioning Plant Rulemaking for User Need Request NSIR-2015-001," dated May 31, 2016 (Reference 21 ), and concluded:

The representative plant staff can reliably implement mitigation strategies to timely mitigate cask-drop events and prevent spent fuel heatup damage; Only the events causing a rapid SFP water draindown (e.g., extreme earthquake and large aircraft impact) would challenge the successful mitigation of fuel heatup; and In the unlikely, worst case beyond-design-basis event leading to a rapid draindown of the SFP and subsequent zirconium cladding fire, there exists additional time margin on the order of 1 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> beyond the 10-hour heatup time in which protective actions can be taken to protect the public before EPA early phase PAGs would be exceeded offsite.

In addition, for this hypothetical event sequence considered in the study above, acute fatal effects offsite appear to be unlikely from either source term evaluated, provided that individuals can be relocated within a reasonable time after plume arrival. In most cases, this time was longer than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

As previously stated, these studies (NUREG-1738, the Sandia studies, NUREG-2161, COMSECY-13-0030, and studies supporting the decommissioning rulemaking efforts) support the NRC staff positions that:

There would be sufficient time between the initiating event and the possible onset of conditions that could result in a zirconium cladding fire, which would provide a substantial opportunity for successful mitigation measures; and Only a highly unlikely, beyond-design-basis event (e.g., extreme earthquake or large aircraft impact) could cause sufficient structural damage to the SFP structure to result in a potential zirconium cladding fire, and even in such cases, the fuel may be air coolable following a complete drain down.

Hostile Action-Based Event Considerations The NRC's regulatory activities and studies have reaffirmed the safety and s~curity of spent fuel stored in pools and shown that SFPs are effectively designed to prevent accidents and minimize damage from malevolent attacks. In the wake of the terrorist attacks of September 11, 2001, the NRC took several actions to further reduce the possibility of an SFP zirconium cladding fire.

The NRC issued Order EA-02-026, dated February 25, 2003 (Reference 22), which required licensees to immediately implement additional security measures, including increased patrols, augmented security forces and capabilities, and more restrictive site-access controls to reduce the likelihood of an SFP accident, resulting from a terrorist-initiated event. The NRC's regulatory actions after the terrorist attacks of September 11, 2001, have significantly enhanced the safety of SFPs. A comprehensive discussion of these actions, some of which specifically address SFP safety and security, is provided in the memorandum to the Commission, entitled "Documentation of Evolution of Security Requirements at Commercial Nuclear Power Plants with Respect to Mitigation Measures for Large Fires and Explosions," dated February 4, 2010 (Reference 23).

Licensees develop strategies in order to protect against the NRC design-basis threat (DBT)6 for radiological sabotage and are required to maintain these strategies under the provisions of 10 CFR 73.55(b) until the termination of their Part 50 ( or Part 52) license. In addition, other Federal agencies, such as the Federal Aviation Administration, the Federal Bureau of Investigation, and the Department of Homeland Security, have taken aggressive steps to prevent terrorist attacks in the United States. Taken as a whole, these systems, personnel, and procedures provide reasonable assurance that public health and safety, the environment, and the common defense and security will be adequately protected (73 FR 46204, 46207; August 8, 2008).

Mitigative Action Considerations The NRC Order EA-02-026 also established new requirements for licensees to have mitigating strategies for the potential loss of SFP water inventory and for large fires or explosions at nuclear power plants. In response, the Nuclear Energy Institute (NEI) provided detailed guidance in NEI 06-12, Revision 2, "B.5.b Phase 2 & 3 Submittal Guideline," dated December 2006 (Reference 24 ), which the NRC endorsed on December 22, 2006 (Reference 25). The NRC found the NEI guidance to be an effective means for mitigating the potential loss of large areas of the plant due to fires or explosions. In addition, these strategies enhanced spent fuel coolability and the potential to recover SFP water level and cooling prior to a potential SFP zirconium cladding fire, which further reduced the probability of a radiological release from an SFP zirconium cladding fire.

Through NRC's issuance of the final rule, "Power Reactor Security Requirements," on March 27, 2009 (74 FR 13926), the requirements in NRC Order EA-02-026 were made generically applicable. In that final rule, the NRC added 10 CFR 50.54(hh)(2) to require licensees to implement mitigating measures to maintain or restore SFP cooling capability in the event of loss of large areas of the plant due to fires or explosions, which further decreases the probability of an SFP zirconium cladding fire. Under 10 CFR 50.54(hh)(2), power reactor licensees are required to implement strategies such as those provided in NEl-06-12.7 Oyster Creek mitigative strategies will continue to be maintained in accordance with License Condition 2.C.(8) of the Oyster Creek RFOL.

Furthermore, other organizations, such as Sandia National Laboratories, as discussed previously under "Spent Fuel Pool Considerations," have confirmed the effectiveness of the additional mitigation strategies to maintain spent fuel cooling in the event that the pool is drained 6 The DBT represents the largest threat against which a private sector facility can be reasonably expected to defend, with high assurance. The NRC's DBT rule was published in the Federal Register on March 19, 2007 (72 FR 12705).

7 The guidance in NEl-06-12 specifies that portable, power-independent pumping capabilities must be able to provide at least 500 gallons per minute (gpm) of bulk water makeup to the SFP, and at least 200 gpm of water spray to the SFP. Recognizing that the SFP is more susceptible to a release when the spent fuel is in a non-dispersed configuration, the guidance also specifies that the portable equipment is to be capable of being deployed within two hours for a non-dispersed configuration.

and its initial water inventory is reduced or lost entirely. The findings of the Sandia studies are sensitive security-related information and are not publicly available.

In response to the Fukushima Dai-ichi Accident, the NRC implemented regulatory actions to further enhance reactor and SFP safety. On March 12, 2012, the NRC issued Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events" (Reference 26), which requires licensees to develop, implement, and maintain guidance and strategies to maintain or restore SFP cooling capabilities, independent of normal alternating current power systems, following a beyond-design-basis external event. In addition, on March 12, 2012, the NRC issued Order EA-12-051, "Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation" (Reference 27), which requires that licensees install reliable means of remotely monitoring wide-range SFP levels to support effective prioritization of event mitigation and recovery actions in* the event of a beyond-design-basis external event. Although the primary purpose of the order was to ensure that operators were not distracted by uncertainties related to SFP conditions during the accident response, the improved monitoring capabilities will help in the diagnosis and response to potential losses of SFP integrity. These requirements ensure a more reliable and robust mitigation capability is in place to address degrading conditions in SFPs resulting from certain significant but highly unlikely events.

Offsite Radiological Emergency Preparedness Considerations The NRC staff determined, based on the EP exemption evaluation criteria discussed in Section 3.0 of this safety evaluation, that in the event of a beyond-design-basis event impacting SFP integrity or the ability to cool spent fuel, the licensee will maintain sufficient resources and adequately trained personnel available on-shift to promptly initiate mitigative actions without the support of OROs. In the highly unlikely event of a zirconium cladding fire in the SFP, due to a beyond-design-basis event that results in the loss of all spent fuel cooling, sufficient time would exist for offsite government officials to implement protective measures, if they deem warranted, using a CEMP, "all-hazards," approach. Therefore, the NRC staff concluded, consistent with previous exemption requests, that formal offsite REP plans, required under 10 CFR Part 50, are not necessary for permanently shut down and defueled nuclear power reactor licensees once the evaluation criteria outlined in Section 5, "Evaluation of Exemptions to EP Regulations," of the Office of Nuclear Security and Incident Response (NSIR), Division of Preparedness and Response (DPR) Interim Staff Guidance (ISG) document NSIR/DPR-ISG-02, "Emergency Planning Exemption Requests for Decommissioning Nuclear Power Plants," dated May 11, 2015 ( Reference 28 ), have been satisfied.

In addition, consistent with the December 7, 2015, "Memorandum of Understanding Between the Department of Homeland Security/Federal Emergency Management Agency and Nuclear Regulatory Commission Regarding Radiological Emergency Response, Planning and Preparedness" (Reference 29), by letter March 9, 2018 (Reference 30), the NRC staff documented the transmittal to the Federal Emergency Management Agency (FEMA), by electronic mail, a draft of the proposed SECY paper and offered the opportunity for FEMA to ask questions, obtain clarification, and comment on the draft SECY paper before the Commission received it for review. In a letter dated April 2, 2018 (Reference 31), FEMA provided the following statement:

As nuclear power plants decommission and the nature of the risk changes, it may affect the capabilities that state and local governments need to maintain offsite to protect the health and safety of the public. Given the risk implications both onsite and offsite during decommissioning, it is imperative that FEMA and the NRC consult with one another when the topic of risk is under discussion. FEMA acknowledges the NRC's role in analyzing incidents that could result in offsite dose impacts, but FEMA also recognizes the authority of state and local governments to determine risk to public health and safety, and the associated capabilities needed to protect their communities. The exemption, if issued, will create a transitional environment for offsite emergency preparedness programs and associated planning for radiological hazards. FEMA will continue to support offsite response organizations (ORO) as they adjust their plans, sustain capabilities, and manage resources to the changing radiological hazard. The resources available to support FEMA stakeholders during the transition process include, but are not limited to, the National Preparedness System guidance materials, the Federal Radiological Preparedness Coordinating Committee, and technical assistance from FEMA Headquarters and FEMA Regions.

In the April 2, 2018, letter, FEMA also stated the following:

FEMA Region II consulted with the New Jersey Office of Emergency Management (NJOEM) concerning this exemption request. At this time, NJOEM does not anticipate any significant reduction in response capabilities at the state or county level due to the OCNGS [Oyster Creek] decommissioning, nor does the state expect to lose any full time emergency management employees; which could degrade staffing capabilities. There may be some budget reallocation required to address some funding areas such as salaries and equipment, but there is no anticipation of any loss or noticeable reduction of response capabilities in the communities surrounding OCNGS.

Exelon would still be required to maintain an onsite emergency plan, which would provide for the notification of, and coordination with, off site organizations, to an extent commensurate with the approved exemptions. Licensee requirements for offsite fire services and law enforcement responding onsite will continue to be maintained under the licensee's fire protection plan and physical security plan in accordance with 10 CFR 50.48 and 10 CFR Part 73, respectively.

The NRC staff recommended that the Commission approve Exelon's requested EP exemptions in SECY-18-0062, "Request by the Exelon Generation Company, LLC for Exemptions from Certain Emergency Planning Requirements for the Oyster Creek Nuclear Generating Station,"

dated May 31, 2018 (Reference 32), which recommendation was approved by the Commission in the SRM to SECY-18-0062, dated July 17, 2018 (Reference 33).

3.0 REGULATORY EVALUATION

The regulations in 1 O CFR 50.12 provide, in part, that the NRC may, on application by a licensee or on its own initiative, grant exemptions from the requirements of the regulations in 10 CFR Part 50 in circumstances in which application of the regulation would not serve the underlying purpose of the rule or is not necessary to achieve the underlying purpose of the rule.8 8 Notwithstanding the special circumstances of the exemption request, 10 CFR 50.12(a)(1) requires that the exemption must be authorized by law, not present an undue risk to the public health and safety, and be consistent with the common defense and security.

As discussed in the Statements of consideration (SOC) for the Final Rule for EP requirements for 10 CFR Parts 50 and 70 ( 45 FR 55402; August 19, 1980, the underlying purposes of the planning standards in 10 CFR 50.47(b), the requirements in 10 CFR 50.47(c)(2), and certain requirements of Section IV of Appendix E to 10 CFR Part 50, are: to ensure that there is reasonable assurance that adequate protective measures can and will be taken in the event of a radiological emergency; and to ensure that licensees maintain effective offsite and onsite radiological emergency response plans.

The NRC staff relied on past precedent to assess whether the Exelon request for EP exemptions satisfied the underlying purposes of the EP regulations. As discussed previously, the exemptions requested by Exelon for Oyster Creek that eliminate requirements for formal offsite REP plans are consistent with those recently approved by the NRC for the Kewaunee Power Station, Crystal River Unit 3 Nuclear Generating Plant, San Onofre Nuclear Generating Station, Units 2 and 3, Vermont Yankee Nuclear Power Station, and Fort Calhoun Station, Unit 1. Prior to these sites, the last approved exemption that eliminated the requirements for formal offsite REP planning was for the Zion Nuclear Power Station in 1999 (Reference 34 ).

The NRC staff recognizes that the planning standards in 10 CFR 50.47(b), the requirements in 10 CFR 50.47(c)(2), and certain requirements in Section IV of Appendix E to 10 CFR 50, were developed taking into consideration the risks associated with accidents that have the potential for significant offsite radiological dose consequences during operation of a nuclear power reactor at its licensed full-power level. As discussed previously, the NRC staff has concluded that after a reactor has permanently shut down and removed all fuel from the reactor vessel to the SFP, the risks associated with accidents that have a potential for offsite radiological release, are significantly reduced for those licensees that are reasonably aligned with the analyses presented in NUREG-1738. This position has been further informed by recent SFP studies provided in NUREG-2161.

Based on the highly unlikely nature of postulated beyond-design-basis events resulting in a loss of SFP integrity or cooling to the spent fuel that may result in significant offsite radiological consequences, the NRC staff considers that the special circumstances condition of 10 CFR 50.12(a)(2)(ii) can be met by demonstrating that Oyster Creek satisfies the two criteria provided below.

Specifically, the planning standards in 10 CFR 50.47(b), the requirements in 10 CFR 50.47(c)(2), and certain requirements in Section IV of Appendix E to 10 CFR 50, from which Exelon has requested exemptions, would not serve or be necessary to achieve the underlying purpose of the EP regulations if the Oyster Creek site-specific analyses demonstrate that:

1. An offsite radiological release for a design-basis accident will not exceed the EPA early phase PAGs of one roentgen equivalent man (rem) at the EAB;9 and
2. In the highly unlikely event of a beyond-design-basis event, resulting in a loss of all modes of cooling for the spent fuel stored in the SFP, there is a minimum of 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> 9 Use of EPA PAGs as a threshold is consistent with the planning basis for the 10-mile EPZ provided in NUREG-0396 (EPA 520/1-78-016), "Planning Basis for the Development of State and Local Government Radiological Emergency Response Plans in Support of Light Water Nuclear Power Plants," December 1978 (Reference 35), and endorsed by the Commission in a policy statement published on October 23, 1979 (44 FR 61123).

for the hottest fuel assembly to reach 900 degrees Celsius (°C), which is the critical temperature threshold for a self-sustained oxidation of zirconium cladding in air. This time provides a substantial opportunity for event mitigation. Licensees are required to maintain effective strategies, sufficient resources, and adequately trained personnel to mitigate such an event.

Previously granted exemptions from EP regulations reduced the level of EP, consistent with the regulations for a licensee authorizing fuel loading and low power testing only, as specified in the standards of 10 CFR 50.47(d), and is consistent with the information requirements for an ISFSI emergency plan, as required by 10 CFR 72.32(a). Examples of the reduced EP requirements include: setting the highest emergency classification level as an "Alert"; extending the timing requirements for notification of offsite authorities; requiring only onsite exercises with the opportunity for ORO participation; and only maintaining arrangements for the OROs (i.e., law enforcement, fire, and medical services) that may respond to onsite emergencies. No formal offsite REP plans, in accordance with 44 CFR Part 350, were required after the exemptions were granted for these licensees.

As part of the review of Exelon's exemption request, the NRC staff used NSIR/DPR-ISG-02, and the EP regulations in 10 CFR 72.32 and "Spent Fuel Project Office Interim Staff Guidance (ISG)- 16, "Emergency Planning," dated June 14, 2000 (Reference 36), as references to ensure consistency between specific-licensed and general-licensed ISFSls. Furthermore, the licensee addressed the Industry Decommissioning Commitments (IDCs)and Staff Decommissioning Assumptions (SDAs)10 that formed the basis of the analyses presented in NUREG-1738.

4.0 TECHNICAL EVALUATION

The following NRC staff evaluation verified that Exelon provided the analyses suggested in Section 5 of NSIR/DPR-ISG-02, and that these analyses meet the criteria in the ISG to justify elimination of the requirement on the licensee to maintain EPZs and formal offsite REP plans and preparedness.

1.

The licensee has performed an analysis indicating that any radiological release from applicable design-basis-accidents would be within 10 CFR 50.67, "Accident source term," dose limits and Regulatory Guide 1.183, "Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors," July 2000 (Reference 39), dose acceptance criteria. The licensee evaluated the maximum 2-hour total effective dose equivalent (TEDE) to an individual located at the EAB, the 30-day TEDE to an individual at the outer boundary of the low population zone, and the control room. The resulting doses would not approach the EPA early phase PAGs recommendation for protection of the public.

The licensee has stated, and the staff confirmed, that while spent fuel remains in the SFP, the only postulated design-basis accident that would remain applicable to the permanently shutdown and defueled Oyster Creek that could contribute a significant 10 Refers to IDCs proposed by NEI in a letter to the NRC dated November 12, 1999 (Reference 37), and several additional SDAs identified through the staffs risk assessment and the staffs evaluation of the safety principles for decommissioning plants in Regulatory Guide 1.174, Revision 2, "An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis," May 2011 (Reference 38). The IDCs and SDAs are summarized in Tables 4.2-1 and 4.2-2 to NUREG-1738.

dose will be a fuel handling accident (FHA) in the Reactor Building, where the SFP is located. For completeness, the staff also evaluated the applicability of other design-basis accidents documented in the Oyster Creek Updated Final Safety Analysis Report (UFSAR) (Reference 40), to confirm that these accidents would not have consequences that could potentially exceed the 10 CFR 50.67 dose limits and Regulatory Guide 1.183 dose acceptance criteria or approach the EPA early phase PAGs.

Fuel Handling Accident - In its analysis, the licensee has determined that within 33 days after permanent cessation of power operations, FHA doses would decrease to a level that would not warrant protective actions under the EPA early phase PAG framework.

The NRC staff notes that the doses from an FHA are dominated by the isotope lodine-131. The licensee has based its application for exemption from certain emergency planning requirements on an effective implementation date of its revised EP and EAL scheme no earlier than 12 months (365 days) after permanent cessation of power operations. Therefore, by the date of implementation of the exemption, the fuel and daughter products will have decayed for at least 12 months (365 days). With 12 months (365 days) of decay, the thyroid dose from an FHA would be negligible. After 12 months of decay, the only isotope remaining in significant amounts, among those postulated to be released in a design-basis FHA, would be Krypton-85. Since Krypton-85 primarily decays by beta emission, the skin dose from an FHA would make an insignificant contribution to the TEDE, which is the parameter of interest in the determination of the EPA early phase PAGs for sheltering or evacuation. Therefore, the NRC staff concludes that the dose consequence from an FHA beyond the 12 months (365 days) after permanent cessation of power operations would not approach the EPA early phase PAGs.

2.

The licensee has performed an analysis demonstrating that a complete loss of SFP water inventory with no heat loss (adiabatic heatup) 12 months after permanent cessation of power operations, a minimum of 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> would be available before any fuel cladding temperature reaches 900 °C from the time all cooling is lost.

The 10-hour criterion, conservatively, does not take into account the fuel uncovery time and assumes instantaneous loss of cooling to the fuel. The 10-hour time period is also not intended to represent the time that it would take to repair all key safety systems or to repair a large SFP breach. The 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> is a conservative period of time in which pre-planned mitigation measures to provide makeup water or spray to the SFP can be reliably implemented before the onset of a zirconium cladding ignition; and, if a release is projected to occur, 1 O hours will be sufficient time for offsite agencies to take appropriate action to protect the health and safety of the public.

In the analysis provided in Attachment 2, "Oyster Creek Nuclear Generating Station Zirconium Fire Analysis for Drained Spent Fuel Pool (Calculation C-1302-226-E310-457),"

to the application dated August 22, 2017, as supplemented by letters dated March 8 and March 19, 2018, the licensee compared the conditions for the hottest fuel assembly stored in the SFP to a criterion proposed in SECY-99-168, "Improving Decommissioning Regulations for Nuclear Power Plants," dated June 30, 1999 (Reference 41 ), applicable to offsite emergency response for the unit in the decommissioning process. This criterion considers the time for the hottest assembly to heat up from 30 °C to 900 °C adiabatically.

If the heat-up time is greater than 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />, then offsite emergency preplanning involving the plant is not necessary. Based on the limiting fuel assembly for decay heat and adiabatic heatup analysis presented in Attachment 2, at 12 months (365 days) after permanent cessation of power operations (i.e., 12 months (365 days) decay time), the time for the hottest fuel assembly to reach 900 °C is more than 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> from the time all cooling is lost. As stated in NUREG-1738, 900 °C is an acceptable temperature to use for assessing onset of fission product release under transient conditions (to establish the critical decay time for determining availability of 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> for deployment of mitigation equipment and, if necessary, for offsite agencies to take appropriate action to protect the health and safety of the public, if fuel and cladding oxidation occurs in air).

The NRC staff reviewed tt,e calculation to verify that important physical properties of materials were within acceptable ranges and that the results were accurate. The NRC staff determined that physical properties were appropriate. Therefore, the NRC staff found that after 12 months (365 days), more than 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> would be available before a significant offsite release could begin. The NRC staff concluded that the adiabatic heat-up calculation provided an acceptable method for determining the minimum time available for deployment of mitigation equipment and, if necessary, implementing measures under a comprehensive general emergency plan.

3.

The licensee has performed an analysis demonstrating that radiation exposure resulting from sky shine due to a loss of SFP water inventory at the EAB and control room indicates less than EPA early phase PAGs at the EAB.

The licensee analyzed the radiological consequences of a beyond-design-basis scenario to evaluate the effects of a loss of water inventory from the SFP. The primary purpose of this calculation is to determine the dose rates as a function of time at the EAB and in the control room due to loss of shielding for an event in which the spent fuel assemblies are uncovered following drain down. The dose rates determined by this calculation are due to direct and indirect radiation from spent fuel assemblies. The NRC staff notes that while the direct dose rate above the unshielded fuel would be high, radiation protection personnel would restrict access to ensure that no one was subjected to the direct dose from the unshielded fuel.

The SFP water and the concrete pool structure serve as radiation shielding. A loss of water shielding above the fuel could increase the offsite radiation levels because of the gamma radiation emitted skyward interacting with air molecules and subsequently scattered back down to the ground where it can expose members of the public (known as sky shine). Attachment 1 to the application provides that the offsite and control room radiological impacts of a postulated complete loss of SFP water were assessed in Calculation C-1302-226-E310-458, "Dose at Exclusion Area Boundary and Control Room Due to Shine from Drained Spent Fuel Pool During SAFSTOR." The licensee determined that the sky shine dose rate at the EAB would be limited to small fractions of the EPA early phase PAGs. The extended period required to exceed the EPA early phase PAG limit would allow sufficient time to develop and implement onsite mitigative actions and provide confidence that additional offsite measures could be taken without planning if efforts to reestablish shielding over the fuel are delayed. The NRC staff reviewed the license's evaluation and performed independent analyses which confirmed the licensee's results. The NRC staff determined that after 12 months (365 days) after permanent cessation of power operations, the EAB dose rate is approximately 2.2 millirem (mrem)/hour and the control room dose rate is approximately 35 mrem/hour.

Therefore, the NRC staff concludes that the dose consequence from sky shine emitted from the SFP due to a loss of SFP normal cooling will not exceed a level that would warrant protective actions under the EPA early phase PAG framework.

4.

Considering the site-specific seismic hazard, the licensee has performed either an evaluation demonstrating a high-confidence of a low-probability (less than 1 x 10-5 per year) of seismic failure of the SFP storage structure, or an analysis demonstrating the fuel has decayed sufficiently that natural air flow in a completely drained pool would maintain peak cladding temperature below 565 °C (the point of incipient cladding damage).

The licensee completed a seismic evaluation in response to a request for information pursuant to the requirements of 10 CFR 50.54(f) regarding recommendation 2.1 of the NRC's Near-Term Task Force Review of insights from the Fukushima Dai-ichi Accident.

The licensee performed the seismic evaluation consistent with NRC guidance and determined that the SFP value for high-confidence of low-probability of failure for the once per 100,000-year hazard level satisfies the pool performance guideline specified in NUREG-1738. The NRC reviewed this evaluation, which is available in "Oyster Creek Nuclear Generating Station - Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(f) Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident (CAC No. MF5257)" dated February 17, 2016 (Reference 42), and determined that the plant-specific seismic risk assessment results are acceptable for Oyster Creek.

5.

If the licensee is storing fuel in an SFP, the licensee should address, for the decommissioning site, the risk reduction measures identified in NUREG-1738 as IDCs and SDAs.

In accordance with the safety analysis in NUREG-1738, the beyond-design-basis event sequences that dominate risk at a decommissioning power reactor are large earthquake and cask-drop events. This is an important difference relative to an operating power reactor, where typically a large number of different initiating events make significant contributions to risk.

Assurance that the results of the NUREG-1738 analysis are representative of the plant-specific conditions at Oyster Creek can be established by assessing the facility against certain design and operational characteristics that were assumed in the NUREG-1738 analysis. These characteristics were identified in the NUREG-1738 study as recovery, mitigation, and emergency response activities assumptions that were relied on to evaluate the likelihood of success in event sequences. In Section 5.5, "Comparison to NUREG-1738 Industry Decommissioning Commitments and Staff Decommissioning Assumptions," and Table 4, "Industry Decommissioning Commitments," of Attachment 1 to the application dated August 22, 2017, the licensee described the conformance of the Oyster Creek facility and operations with the IDCs and the SDAs. In the licensee's discussion of the IDCs and SDAs, the licensee addressed measures in place to minimize the potential risk from event sequences that dominate risk at a decommissioning reactor with fuel stored in an SFP (for example, those IDCs and SDAs related to fuel cask handling activities and seismic events).

The NRC staff's evaluation focused on the licensee's conformance with IDCs and SDAs that are related to the design and operation of structures, systems, and components associated with the SFPs. The following provides a summary of the staff's findings, based on an assessment of the licensee's IDC and SDA items:

IDC #1:

Cask drop analyses will be performed or single-failure-proof cranes will be used for handling of heavy loads (i.e., phase II of NUREG-0612, ["Control of Heavy Loads at Nuclear Power Plants: Resolution of Generic Technical Activity A-36"] (Reference 43), will be implemented).

To provide for safe handling of heavy loads in the vicinity of the SFP, the licensee has maintained equipment and procedures for handling heavy loads that comply with NUREG-0612 guidelines for single-failure-proof handling systems. The cask handling crane (i.e., reactor building bridge crane) trolley was upgraded to a single failure proof design in accordance with NUREG-0612 to provide redundancy in the load carrying path from the cask to the crane trolley itself, so that no single failure would allow the cask to drop. In addition to the trolley replacement, the licensee implemented a comprehensive maintenance program and strict administrative control of all cask handling. The NRC staff found that the qualification and operation of the cask handling crane as a single-failure-proof handling system satisfies the conditions assumed in the analysis presented in NUREG-1738 with respect to protection from potential cask drop events.

IDC #2:

Procedures and training of personnel will be in place to ensure that onsite and offsite resources can be brought to bear during an event.

IDC #3:

Procedures will be in place to establish communication between onsite and offsite organizations during severe weather and seismic events.

IDC #4:

An offsite resource plan will be developed which will include access to portable pumps and emergency power to supplement onsite resources. The plan would principally identify organizations or suppliers where offsite resources could be obtained in a timely manner.

The licensee listed and described how various plant procedures would provide for deployment of onsite resources and access to offsite resources, including provisions for training, communications, and coordination to obtain offsite resources. Therefore, the NRC staff concludes the licensee has adequate procedures to satisfy the conditions assumed in the NUREG-1738 analysis regarding effective use of onsite and offsite resources to respond to events affecting the SFP.

IDC #5:

SFP instrumentation will include readouts and alarms in the control room (or where personnel are stationed) for SFP temperature, water level, and area radiation levels.

The licensee described that the SFP instrumentation included instruments, indicators, and alarms for SFP water level, temperature, and radiation levels.

There is a continuous temperature monitor that reads out locally without any power. It provides a high-temperature alarm function in the control room (powered by vital direct current (DC)). The temperature gauge is read via dedicated video to the control room. SFP level is monitored by the control room with continuous dedicated video display of surge tank level and surge tank "lo" and "lo-lo" level annunciators. The SFP low-level annunciator in the control room is actuated by a continuous level instrument that senses a level below the surge tank weir height. In addition, there are two channels of continuous remote indication of the SFP water level indicators in the cable spreading room above the control room that have been added for reliable SFP level indication (post-Fukushima). There are two channels of continuous remote indication of refueling floor area radiation in the control room. Each of these channels provide high-area radiation annunciation in the control room.

A local alarm to notify personnel of high-area radiation levels is also in place.

In addition, each of these channels provides input to the plant computer.

Therefore, the NRC staff found that the licensee will maintain adequate SFP monitoring instrumentation to satisfy the conditions assumed in the Nl.JREG-1738 analysis regarding monitoring events affecting the SFP.

IDC #6:

SFP seals that could cause leakage leading to fuel uncovery in the event of seal failure shall be self-limiting to leakage or otherwise engineered so that drainage could not occur.

The passage between the fuel storage pool and the refueling cavity above the reactor vessel is provided with two double sealed gates with a monitored drain between the gates. This arrangement permits detection of leaks from the passage and repair of the gates in the event of such leakage. If SFP inventory were to leak due to seal rupture or degradation, the level would not go below the top of the spent fuel racks. The top elevation of the fixed refueling slot between the SFP and reactor vessel where the removable refueling slot plug is placed over is at elevation 94 feet (') - 9 inches ("). The top elevation of a spent fuel rack in the SFP is 94'-6". The NRC staff found that the described design features that limit the potential for drainage through the gate openings are consistent with the assumptions used in the analysis presented in NUREG-1738.

IDC #7:

Procedures or administrative controls to reduce the likelihood of rapid drain-down events will include (1) prohibitions on the use of pumps that lack adequate siphon protection, and (2) controls for pump suction and discharge points. The functionality of anti-siphon devices will be periodically verified.

The licensee described procedures and design elements that reduce the likelihood of a rapid drain-down event. The licensee described general work process procedures controlling work to maintain safety. All work activities are subject to the work process controls and integrated risk management where the activities are analyzed and managed for risk. (e.g., address SFP activities). Oyster Creek Procedure EN-HU-106, "Procedure and Work Instruction Use and Adherence," establishes the expectations and requirements for procedure adherence and usage for all personnel performing activities. Additionally, all work activities are subject to the work process controls and integrated risk management where the activities are analyzed and managed for risk (e.g. address SFP activities). Oyster Creek Procedure 311, "Fuel Pool Cooling System," allows specified volumes to be pumped or letdown from the SFP. This procedure meets the requirements of this IDC by controlling the suction and discharge points. The NRC staff found that the described procedures or administrative controls, and design features minimize the potential for rapid drainage through permanent systems and are consistent with the assumptions used in the analysis presented in NUREG-1738.

IDC #8:

An onsite restoration plan will be in place to provide repair of the SFP cooling systems or to provide access for makeup water to the SFP. The plan will provide for remote alignment of the makeup source to the SFP without requiring entry to the refuel floor.

The licensee described procedures in place to restore the SFP cooling systems, provide normal makeup to the SFP, and provide an alternate path for makeup water to the SFPs without requiring entry to the refueling floor.

The NRC staff found that the planned SFP cooling and make-up water capability conformed to the capabilities assumed for the staff analysis presented in NUREG-1738.

IDC #9:

Procedures will be in place to control SFP operations that have the potential to rapidly decrease SFP inventory. These administrative controls may require additional operations or management review, management physical presence for designated operations or administrative limitations such as restrictions on heavy load movements.

The licensee described that procedures govern SFP operations, such as water transfer or ISFSI activities that could have the potential to rapidly decrease SFP inventory. The licensee stated that all work activities are subject to the work process controls and integrated risk management where the activities are analyzed and managed for risk. Procedures control water inventory during ISFSI operations and ensure the single-failure-proof attributes of the heavy load handling system are maintained. The NRC staff found that the described procedures conformed to the administrative controls considered in the staff analysis presented in NUREG-1738.

IDC #10: Routine testing of the alternative fuel pool makeup system components will be performed and administrative controls for equipment out of service will be implemented to provide added assurance that the components would be available, if needed.

The licensee described several alternate makeup sources including the Oyster Creek electric-driven fire pumps and diesel-driven main fire pumps that can supply makeup water to the SFP via the service water system or the fire water system. The Oyster Creek Fire Protection Program provides controls for operation with equipment out of service and periodic functionality testing. Oyster Creek also has two diesel-driven engine emergency makeup pumps capable of taking suction from the intake water to satisfy FLEX requirements.

In addition, the licensee stated that procedures contain the licensee's maintenance and testing requirements for equipment designated for strategies to maintain or restore spent fuel cooling. The NRC staff found that the described administrative controls conform to those considered in the staff analysis presented in NUREG-1738.

SDA #1:

SFP cooling design will be at least as capable as that assumed in the risk assessment, including instrumentation. Licensees will have at least one motor-driven and one diesel-driven fire pump capable of delivering inventory to the SFP.

The SFP cooling system design is based, in part, on Regulatory Guide 1.13, Revision 2, "Spent Fuel Storage Facility Design Basis," March 2007 (Reference 44) which included, in part, a Seismic Category I makeup system to add coolant to the SFP. The station's design also includes electric-driven fire pumps and diesel-driven fire pumps; both types will be maintained until all fuel is removed from the SFP. Each fire pump has the capability to deliver 500 gallons per minute of makeup water to the SFP. Instrumentation was described in the discussion of IDC #5. The NRC staff found the described cooling and makeup capabilities are comparable to the capabilities considered in the staff analysis presented in NUREG-1738.

SDA #2:

Walk-downs of SFP systems will be performed at least once per shift by the operators. Procedures will be developed for and employed by the operators to provide guidance on the capability and availability of onsite and offsite inventory makeup sources and time available to initiate these sources for various loss-of-cooling or inventory events.

The licensee stated that personnel perform a walk-down of SFP systems once per day. As described later in the response to SDA #3, there are various methods available to the control room for monitoring the SPF, therefore walk-downs may not be as frequent as originally describe in NUREG-1738. Procedures provide the necessary guidance to address loss of SFP cooling and loss-of-level conditions. The NRC staff found that the proposed monitoring of the SFP systems would be comparable to the capability assumed for the staff analysis presented in NUREG-1738.

SDA #3:

Control room instrumentation that monitors SFP temperature and water level will directly measure the parameters involved. Level instrumentation will provide alarms at levels associated with calling in offsite resources and with declaring an emergency.

The licensee described that control room SFP temperature instrumentation includes a continuous temperature monitor that reads out locally without any power. It provides a high temperature alarm function in the control room (powered by vital DC). The temperature gauge is read via dedicated video to the control room. SFP level is monitored by the control room with continuous dedicated video display of surge tank level and surge tank "lo" and "lo-lo" level annunciators. The SFP "lo level" annunciator in the control room is actuated by a continuous level instrument that senses a level below the surge tank weir height. Additionally, there are two channels of continuous remote indication of the SFP water level indicators in the cable spreading room above the control room that have been added for reliable SFP level indication (post-Fukushima). The NRC staff finds that the SFP monitoring capability is consistent with the assumptions in the analysis presented in NUREG-1738.

SDA #4:

Licensee determines that there are no drain paths in the SFP that could lower the pool level (by draining, suction, or pumping) more than 15 feet below the normal pool operating level and that licensee must initiate recovery using offsite sources.

The licensee described potential drain or siphon paths within the SFP.

Neither of the normal SFP cooling suction and discharge paths within the SFP could lower pool level more than 15 feet below the normal operating level. The normal SFP cooling system suction lines are from weir feed surge tanks. Weir lip is at 118'-2", which is approximately 24 feet above the top of active fuel. The return line is protected from siphoning by check valves and passive vacuum break holes. This is seismically rated piping. The SFP lowest drain path is via the 3-inch drain line located between the inboard and outboard SFP gates, located at elevation 94' -6", which is located

  • approximately 24 feet below normal SFP water level. Drain-down to this elevation, which is 3 inches above the top of the spent fuel racks, prevents uncovering of fuel. However, this path requires a gross failure of the inboard gate sealing gasket as well as failure of the 3-inch drain line. As discussed previously in IDC #6, the passage between the fuel storage pool and the refueling cavity above the reactor vessel is provided with two double sealed gates with a monitored drain between the gates. This arrangement permits detection of leaks from the passage and repair of the gates in the event of such leakage. If SFP inventory were to leak due to seal rupture or degradation, the level would not go below the top of the spent fuel racks.

Therefore, the SFP design reasonably protects against drainage that results in fuel uncovery consistent with the assumptions used in the analysis presented in NUREG-1738. As discussed previously in IDC #4, the licensee listed and described how various plant procedures would provide for deployment of onsite resources and access to offsite resources, including provisions for training, communications, and coordination to obtain offsite resources SDA #5:

Load drop consequence analysis will be performed for facilities with non-single failure-proof systems. The analyses and any mitigative actions necessary to preclude catastrophic damage to the. SFP that would lead to a rapid pool draining would be sufficient to demonstrate that there is high enough confidence in the facility's ability to withstand a heavy load drop.

As discussed under IDC #1, the licensee committed to use single-failure-proof cranes for such loads. Therefore, the protection against heavy load drops is consistent with the assumptions considered in the analysis presented in NUREG-1738.

SDA #6:

Each decommissioning plant will successfully complete the seismic checklist provided in Appendix 2B to NUREG-1738. If the checklist cannot be successfully completed, the decommissioning plant will perform a plant-specific seismic risk assessment of the SFP and demonstrate that SFP seismically induced structural failure and rapid loss of inventory is less than the generic bounding estimates provided in NUREG-1738 (<1 x 10-5 per year including non-seismic events).

The licensee completed a seismic evaluation in response to an NRC request for information pursuant to the requirements of 10 CFR 50.54(f) regarding recommendation 2.1, "Seismic," of the NRC's Near-Term Task Force Review of insights from the Fukushima Dai-ichi accident. The seismic evaluation was performed consistent with NRC guidance and determined that the SFP value for high-confidence of low-probability of failure for the once per 100,000 year hazard level satisfies the pool performance guideline specified in NUREG-1738. The NRC's review of this evaluation is available in the NRC letter dated February 17, 2016 (Reference 42). Therefore, the plant-specific seismic risk assessment results are acceptable for Oyster Creek.

Additionally, Section 5.6, "Consequences of a Beyond Design-Basis Earthquake," of Attachment 1 to the application compares the Oyster Creek spent fuel storage characteristics with those of the reference plant evaluated by the staff in NUREG-2161. However, the comparison does not address the distribution of recently discharged fuel (an important parameter used in the NUREG-2161 evaluation) that will exist once the Oyster Creek reactor is permanently defueled. On November 16, 2017, the NRC staff issued a request for additional information (RAI), RAI-OCNGS-10 (Reference 45),

requesting the licensee to describe the fuel distribution that will exist at the time the emergency plan changes that would be permitted by the requested exemption, are scheduled for implementation.

In its December 6, 2017, response to the NRC staff's RAI, the licensee clarified that the fuel will be thermally dispersed at the time the emergency plan changes permitted by this exemption are implemented. The fuel that is removed from the reactor after permanent cessation of power operations is considered the "hottest" fuel and will have decayed for 1 year at the time that this exemption commences. The "hottest" fuel bundles will be dispersed in a pattern where cooler fuel (removed from the reactor for at least 4 years) with less decay heat will surround the hottest bundles. Storing spent fuel in a dispersed pattern in a SFP promotes air coolability of the spent fuel in the unlikely event of loss of water. The licensee further stated that the fuel distribution in the SFP will be bounded by that assumed in NUREG-2161 because Oyster Creek fuel is from a lower powered reactor and there will be fewer total fuel bundles in the SFP than present in the reference plant SFP described in NUREG-2161.

SDA #7:

Licensees will maintain a program to provide surveillance and monitoring of Boraflex in high-density spent fuel racks until such time as spent fuel is no longer stored in these high-density racks.

Oyster Creek has high density spent fuel racks that utilize two types of neutron poison: 10 Boraflex racks and four Boral racks of similar design. As described in Section 9.1.2.3.9.1 of the Oyster Creek UFSAR, an aging management program is in place to manage loss of material and reduction of neutron absorption capacity of Boraflex neutron absorption panels in the spent fuel racks. The loss of material and the reduction of the neutron-absorbing capacity will be determined through in-situ testing and NRC-accepted RACKLIFE modeling. Boral performance is assessed by the surveillance program that utilizes test coupons.

Based on the above evaluations, the NRC staff concludes that the design and operation of structures, systems, and components associated with SFP storage provide for safe storage of spent fuel and are consistent with the capabilities assumed in the analysis presented in NUREG-1738.

6.

Verification that the licensee presents a determination that there are sufficient resources and adequately trained personnel available on-shift to promptly initiate mitigative actions within the 10-hour minimum time period that will prevent an offsite radiological release that exceeds the EPA early phase PAGs at the EAB.

Oyster Creek mitigative strategies are maintained in accordance with License Condition 2.C.(8) of the Oyster Creek Renewed Facility Operating License. Specific to the implementation of NEl-06-12, Table A.2-2, "SFP Makeup - External Strategy," can be performed by the proposed on-shift staffing of a Non-Certified Operator (NCO), Shift Manager (SM) and Radiation Protection Technician (RPT) required to support mitigating strategies for a catastrophic loss of SFP water inventory. While the SM will be responsible for directing the mitigating strategies, in addition to his emergency preparedness tasks, the NCO and RPT would not have any concurrent emergency preparedness tasks during performance of mitigating strategies. The in-plant team performing SFP mitigating strategies would have normal shift electronic dosimetry, monitoring, and radiation protection controls that exist for in-plant shift workers. This would alleviate any concurrent tasks that the RPT would need to perform while performing mitigating strategies. The ability to perform the required actions within the specified time is documented and retained at the station for review. The systematic*

approach to training is implemented to ensure operations and other appropriate personnel receive initial and continuing training on 8.5.b event-related procedures and strategies credited in the Mitigation Strategy License Condition.

7.

Verification that mitigation strategies are consistent with that required by the permanently defueled technical specifications (TSs) or by retained license conditions.

Oyster Creek maintains procedures and strategies for the movement of any necessary portable equipment that will be relied upon for mitigating the loss of SFP water. These mitigative strategies were developed in response to 10 CFR 50.54(hh){2) and are maintained in accordance with License Condition 2.C.(8) of the Oyster Creek Renewed Facility Operating License. These diverse strategies provide defense-in-depth and ample time to provide makeup water or spray to the SFP prior to the onset of zirconium cladding ignition when considering very low probability beyond-design-basis events affecting the SFP.

5.0 EXEMPTIONS Pursuant to 10 CFR 50.12, the Commission may, upon application by any interested person or upon its own initiative, grant exemptions from the requirements of 10 CFR Part 50: (1) when the exemptions are authorized by law, will not present an undue risk to public health and safety, and are consistent with the common defense and security, and (2) when special circumstances are present.

Special circumstances exist, in part, when application of the regulation in the particular circumstance would not serve the underlying purpose of the rule or is not necessary to achieve the underlying purpose of the rule (10 CFR 50.12(a)(2)(ii)). The underlying purpose of the planning standards in 10 CFR 50.47(b), the requirements in 10 CFR 50.47(c)(2), and certain requirements of Section IV of Appendix E to 10 CFR Part 50, are: to ensure that there is reasonable assurance that adequate protective measures can and will be taken in the event of a radiological emergency; and to ensure that licensees maintain effective offsite and onsite radiological emergency response plans.

This section reflects the NRC staff's technical evaluation of the licensee's exemption requests, as provided to the Commission in SECY-18-0062, which was approved by the Commission in the SRM to SECY-18-0062.

5.1 Specific Exemptions for 10 CFR 50.47 Exelon's letter dated August 22, 2017, requested an exemption from certain sections (as indicated by strikeout and bolded text) of 10 CFR 50.47 for Oyster Creek.

5.1.1 10 CFR 50.47(b)

The onsite aml, e>Esept as pFe¥iEleEI in paFagFaph (El) ef this seGtien, effsite emergency response plans for nuclear power reactors must meet the following standards:

The NRC requires a level of licensee EP commensurate with the potential consequences to public health and safety, and common defense and security at the licensee's site. Exelon's exemption request included radiological analyses to show that, as of 33 days after permanent cessation of power operations, the radiological consequences of remaining applicable design-basis accidents would not exceed the limits of the EPA early phase PAGs at the EAB.

The licensee also concluded and the NRC staff confirmed, as of 12 months (365 days) after permanent cessation of power operations, in the highly unlikely event of a loss of SFP integrity, due to a beyond-design-basis event, resulting in all cooling is lost to the spent fuel and a heat up under adiabatic conditions resulted, at least 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> would be available to take mitigative actions before the hottest fuel assembly reached 900 °C.

NUREG-1738, and enhancements put into place as a result of the events of September 11, 2001, and the Fukushima Dai-ichi Accident, support staff assumptions that: only a highly unlikely, beyond-design-basis event (e.g., extreme earthquake or large aircraft impact) could result in an SFP fire. In addition, there would be a significant amount of time between the initiating event and the possible onset of conditions that could result in an SFP zirconium cladding fire. This time provides a substantial opportunity for event mitigation. Licensees are required to maintain effective strategies, sufficient resources, and adequately trained personnel to mitigate such an event. If State or local governmental officials determine that offsite protective actions are warranted, then sufficient time and capability would be available for OROs to implement these measures using a CEMP, "all-hazards," approach.

Considering the very low probability of beyond-design-basis events affecting SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not necessary for a permanently shut down and defueled nuclear power reactor.

Based on the above analysis, the NRC staff concludes that the exempted language from 10 CFR 50.47(b) above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provisions of 1 O CFR 50.12(a)(2)(ii).

5.1.2 10 CFR 50.47(b)(1)

Primary responsibilities for emergency response by the nuclear facility licensee and by State and local organizations within the EmergenGy Planning Zones have been assigned, the emergency responsibilities of the various supporting organizations have been specifically established, and each principal response organization has staff to respond and to augment its initial response on a continuous basis.

NUREG-0396 provided that emergency response plans should be useful for responding to any accident that would produce offsite radiological doses in excess of the EPA PAGs. Additionally, it introduced the concept of generic plume exposure pathway zones as a basis for the planning of response actions, which would result in dose savings in the environs of nuclear facilities in the event of a serious power reactor accident. As previously discussed, Exelon has provided radiological analyses, which show that, as of 12 months (365 days) after permanent cessation of power operations, the radiological consequences for design-basis accidents at Oyster Creek will not exceed the limits of the EPA early phase PAGs at the EAB. In addition, reactor core melt (Class 9) scenarios, which were also considered in NUREG-0396, are no longer applicable to a permanently shut down and defueled power reactor.

In the SOC for the Final Rule for EP requirements for ISFSls and for MRS facilities (60 FR 32430; June 22, 1995), the Commission responded to comments concerning an EPZ for an ISFSI and MRS, and concluded that, "based on the potential inventory of radioactive material, potential driving forces for distributing that amount of radioactive material, and the probability of the initiation of these events, the Commission concludes that the offsite consequences of potential accidents at an ISFSI or a MRS would not warrant establishing Emergency Planning Zones."

Oyster Creek's exemption request provided radiological analyses to show that, as of 33 days after permanent cessation of power operations, the radiological consequences of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs to the public beyond the EAB. Considering the very low probability of beyond-design-basis events affecting SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, designated plume exposure and ingestion pathway EPZs are no longer needed.

Based on the above analysis, the NRC staff concludes that the exempted language from 10 CFR 50.47(b)(1 ), above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.1.3 10 CFR 50.47(b )(3)

Arrangements for requesting and effectively using assistance resources have been made, arraRgemeRts to assommoElate State aREI losal staff at the liseRsee's EmergeRGy OperatioRs Fasility have heeR maEle, and other organizations capable of augmenting the planned response have been identified.

With the termination of reactor power operations at Oyster Creek and the permanent removal of the fuel from the reactor vessel to the SFP, most of the accident scenarios postulated for operating reactors are no longer possible. The spent fuel will be stored in the SFP and the ISFSI, and will remain onsite until it can be moved offsite for long-term storage or disposal. The reactor, reactor coolant system (RCS) and supporting systems are no longer in operation and have no function related to the storage of the spent fuel. Therefore, postulated accidents involving failure or malfunction or the reactor, RCS, or supporting systems are no longer applicable. During reactor decommissioning, the principal public safety concerns involve the radiological risks associated with the storage of spent fuel onsite.

The emergency operations facility (EOF) is a support facility for the purpose of managing the overall licensee emergency response (including coordination with Federal, State, and local officials), coordination of radiological and environmental assessments, and determination of recommended public protective actions. Oyster Creek's exemption request provided radiological analyses to show that, as of 33 days after permanent cessation of power operations, the radiological consequences of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs to the public beyond the EAB. Considering the very low probability of beyond-design-basis events affecting SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, an EOF would not be needed to coordinate these types of assessments for determining public protective actions. Onsite operations staff will continue to maintain and provide for communication and coordination capabilities with offsite authorities and OROs for the purpose of notification and for the level of support required for remaining design-basis accidents and the prompt implementation of mitigative actions in response to an event affecting the SFP.

Based on the above analysis and the analysis provided in Section 5.1.1 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR 50.47(b)(3),

above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.1.4 10 CFR 50.47(b)(4)

A standard emergency classification and action level scheme, the bases of which include facility system and effluent parameters, is in use by the nuclear facility licensee, aREI State aREI losal respoRse plaRs sall f.or reliaRGe OR iRf.ormatioR proviEleEI by fasility liseRsees for EletermiRatioRs of miRimum iRitial offsite respoRse measures.

Oyster Creek's exemption request provided radiological analyses to show that, as of 33 days after permanent cessation of power operations, the radiological consequences of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs to the public beyond the EAB. Considering the very low probability of beyond-design-basis events affecting SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement for minimum initial offsite response measures is not required.

Based on the above analysis and the analysis provided in Section 5.1.1 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR 50.47(b)(4),

above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 1 O CFR 50.12(a)(2)(ii).

5.1.5 10 CFR 50.47(b)(5)

Procedures have been established for notification, by the licensee, of State and local response organizations and for notification of emergency personnel by all organizations; the content of initial and follow-up messages to response organizations and the public has been established; and means to provide early notification and clear instruction to the populace \\*Jithin the plume exposure pathway Emergency Planning Zone have been established.

Oyster Creek's exemption request provided radiological analyses to show that, as of 33 days after permanent cessation of power operations, the radiological consequences of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs to the public beyond the EAB. Considering the very low probability of beyond-design-basis events affecting SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, a means to provide early notification and clear instruction to the populace within a designated plume exposure pathway EPZ is no longer required.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.1.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR 50.47(b )(5), above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.1.6 10 CFR 50.47(b)(6)

Provisions exist for prompt communications among principal response organizations to emergency personnel and to the public.

Oyster Creek's exemption request provided radiological analyses to show that, as of 33 days after permanent cessation of power operations, the radiological consequences of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs to the public beyond the EAB. Considering the very low probability of beyond-design-basis events affecting SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement to provide prompt communication to the public within a designated plume exposure pathway EPZ in regards to initial or pre-determined protective actions is no longer needed.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.1.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR 50.47(b )(6), above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.1. 7 10 CFR 50.47(b )(7)

Information is made a*Jailable to the publie on a periodie basis on how they will be notified and what their initial aetions should be in an emergeney (e.g., listening to a loeal broadeast station and remaining indoors), [T]he principal points of contact with the news media for dissemination of information during an emergency (ineluding the physieal loeation or loeations) are established in advance, and procedures for coordinated dissemination of information to the public are established.

Oyster Creek's exemption request provided radiological analyses to show that, as of 33 days after permanent cessation of power operations, the radiological consequences of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs to the public beyond the EAB. Considering the very low probability of beyond-design-basis events affecting SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement to provide periodic information to the public within a designated plume exposure pathway EPZ on how they will be notified and what their initial or predetermined protective actions should be in an emergency is not needed.

Based on the above analysis and the analysis provided in Sections 5.1.1 and 5.1.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR 50.47(b)(7),

above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.1.8 10 CFR 50.47(b )(9)

Adequate methods, systems, and equipment for assessing and monitoring actual or potential offsite consequences of a radiological emergency condition are in use.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement for assessing or monitoring offsite consequences beyond the EAB is not needed.

Based on the above analysis and the analysis provided in Section 5.1.1 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR 50.47(b)(9),

above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.1.9 10 CFR 50.47(b)(10)

A range of protective actions has been developed for the ph:1me e*.posure pathway EPZ for emergency workers and the public. In developing this range of aGtions, consideration has been given to e*,acuation, sheltering, and, as a supplement to these, the prophylactic use of potassium iodide (Kl), as appropriate. Evacuation time estimates have been developed by applicants and licensees. licensees shall update the e*,acuation time estimates on a periodic basis. Guidelines for the choice of proteGti*,e aGtions during an emergency, consistent with Federal guidance, are developed and in place, and proteGtive actions for the ingestion e*.posure path*.tJay EPZ appropriate to the locale have been de\\*eloped.

The Commission provided its view on evacuation planning for an ISFSI (not at an operating reactor site) in its SOC for the Final Rule for EP requirements for an ISFSI and a MRS (60 FR 32430; June 22, 1990) stating: "The Commission does not agree that as a general matter emergency plans for an ISFSI must include evacuation planning."

The NRC staff has determined that no credible events within the design basis would result in doses to the public that would exceed the EPA early phase PAGs at the EAB. Therefore, EPZs beyond the EAB and the associated protective actions developed from evacuation time estimates (ETEs) are no longer required. Additionally, in the unlikely event of an SFP accident, the iodine isotopes, which contribute to an offsite dose from an operating reactor power accident, are not present, so Kl distribution would no longer serve as an effective or necessary supplemental protective action. As such, the NRC staff concludes that Exelon provides for an acceptable level of emergency planning at Oyster Creek in its permanently shutdown and defueled condition, and also provides reasonable assurance that adequate protective measures can and will be taken in the event of a radiological emergency at Oyster Creek.

Although formal offsite REP plans (in accordance with 44 CFR Part 350) have typically been exempted for decommissioning sites, OROs will continue to be relied upon for firefighting, law enforcement, ambulance and medical services in support of the licensee's (onsite) emergency plan. The licensee is responsible for providing protective measures for any emergency workers responding onsite. Additionally, the licensee is responsible for control of activities within the EAB, including public access. The licensee actions that are necessary to protect the health and safety of members of the public who are in the EAB may include, but are not limited to, evacuation, sheltering and decontamination in the unlikely event of a release of radioactive materials.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.1.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR 50.47(b)(10), above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.1.10 10 CFR 50.47(c)(2)

GeneFally, the plume eJCpesuFe pathway iPZ f.eF nuGleaF peweF plants shall Gensist ef an aFea abeut 10 miles (16 km) in radius and the ingestion pathway iPZ shall Gensist ef an aFea abeut 50 miles (80 km) in radius. The eJCaGt size and Genliguratien ef the iP.ls suFFeunding a partiGulaF nuGleaF p8'NeF FeaGteF shall be deteFmined in Felatien te leGal emeFgenGy Fespense needs and Gapabilities as they aFe affeGted by suGh Genditiens as demegraphy, tepegFaphy, land GhaFaGteFistiGs, aGGess Feutes, and juFisdiGtienal beundaFies. The size of the EPZs al&e-may be determined on a case-by-case basis for gas-cooled nuclear reactors and for reactors with an authorized power level less than 250 MW thermal. The plans f.eF the ingestion path*.*.*ay shall f.eGus en suGh aGtiens as aFe appF8pFiate te pFeteGt the feed ingestion pathway.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement for an EPZ is not required.

Section 50.47(c)(2) and footnote 1 to Appendix E to 10 CFR Part 50 both state, in part: "The size of the EPZs also may be determined on a case-by-case basis for gas-cooled nuclear reactors and for reactors with an authorized power level less than 250 MW [megawatt] thermal."

This is not applicable to Oyster Creek and, therefore, requires no exemption.

Based on the above analysis and the analysis provided in Section 5.1.9 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR 50.47(c)(2),

above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2 Specific Exemptions for 10 CFR Part 50, Appendix E,Section IV Exelon's letter dated August 22, 2017, requested an exemption from certain sections (as indicated by strikeout and bolded text) of Appendix E to 10 CFR Part 50 for Oyster Creek.

5.2.1 10 CFR Part 50, Appendix E,Section IV.1 The applicant's emergency plans shall contain, but not necessarily be limited to, information needed to demonstrate compliance with the elements set forth below, i.e., organization for coping with radiological emergencies, assessment actions, activation of emergency organization, notification procedures, emergency facilities and equipment, training, maintaining emergency preparedness, recovery, and onsite protective actions during hostile action. In addition, the emergency response plans submitted by an applicant for a nuclear power reactor operating license under this part, or for an early site permit (as applicable) or combined license under 10 CFR part 52, shall contain information needed to demonstrate compliance with the standards described in§ 50.47(b), and they will be evaluated against those standards.

After the terrorist attacks of September 11, 2001, NRC evaluated the EP planning basis to ensure that it continued to protect the public health and safety in the current threat environment.

In 2002, the NRC issued Orders requiring compensatory measures, which include nuclear security and EP. The NRC staff determined that the EP planning basis continues to protect public health and safety; however, the NRC staff recognized that enhancements were desirable to ensure effective plan implementation during security-related events at nuclear power reactors (e.g., more timely NRC notification; additional onsite protective action considerations, and revision of emergency action levels to identify security-related emergencies more succinctly).

The NRC issued NRC Bulletin (BL) 2005-02, "Emergency Preparedness and Response Actions for Security-Based Events," dated July 18, 2005 (Reference 46), to obtain information from licensees on progress in implementing security-event-related EP program enhancements. The 2011 EP Final Rule, "Enhancements to Emergency Preparedness Regulations" (76 FR 72560; November 23, 2011 ), made generically applicable the security-based response elements of NRC BL 2005-02. The enhancements of NRC BL 2005-02 were not applicable to holders of operating licenses for power reactors that had permanently ceased operations and had certified that fuel had been removed from the reactor vessel. Therefore, the enhancements for hostile actions, as required by the 2011 EP Final Rule, are not necessary for Oyster Creek in a permanently shut down and defueled status.

Additionally, the NRC excluded non-power reactors from the definition of "hostile action" at the time of the 2011 EP Final Rule because, as defined in 10 CFR 50.2, a non-power reactor is not considered a nuclear power reactor and a regulatory basis had not been developed to support the inclusion of non-power reactors in the definition of "hostile action." Similarly, a decommissioning power reactor or ISFSI is not a "nuclear reactor" as defined in the NRC's regulations. Like a non-power reactor, a decommissioning nuclear reactor also has a lower likelihood of a credible accident resulting in radiological releases requiring offsite protective measures than does an operating nuclear reactor. For all of the above reasons, the NRC staff concludes that a decommissioning nuclear power reactor is not a facility that falls within the definition of "hostile action."

Although this analysis provides a justification for exempting Oyster Creek from "hostile action" related requirements, some EP requirements for security-based events are maintained. The classification of security-based events, notification of offsite authorities, and coordination with offsite agencies are still required.

Based on the above analysis, the NRC staff concludes that the exempted language from 1 O CFR Part 50, Appendix E,Section IV.1, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provisions of 10 CFR 50.12(a)(2)(ii).

5.2.2 10 CFR Part 50, Appendix E,Section IV.2 This RUGlear p8ti."Jer reaGter liGeRse appliGaRt shall alse previde aR aRal)'"6is ef the time FeE1uired te ewGuate wrieus seGters aRd distaRGes withiR the plume eJC.pesure paUwtay &PZ fer traRsieRt aRd permaReRt pepulatieRs usiRg the mest reGeRt U.S. CeRsus Bureau data as ef the date the appliGaRt submits its appliGatieR te the NRC.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirements for an EPZ and ETEs are not required.

Based on the above analysis and the analyses provided in Section 5.1.9 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.2, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.3 10 CFR Part 50, Appendix E,Section IV.3 NuGlear p~wer reaGter liGeRsees shall use NRC appreved e'.taGuatieR time estimates (&T&s) aRd updates te the &T&s iR the fermulatieR ef preteGtive aGtieR reGemmeRdatieRs aRd shall previde the &T&s aRd &T& updates te State aRd leGal geverRmeRtal autherities fer use iR de¥elepiRg effsite preteGti¥e aGtieR strategies.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after the permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Since formal offsite REP plans are not needed, the requirement to have an ETE and to perform an update to the ETE is not needed.

Based on the above analysis and the analysis provided in Section 5.2.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.3, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.4 10 CFR Part 50, Appendix E,Section IV.4 Within 365 Elays of the later of the Elate of the a¥ailability of the most resent Elesennial sensus Elata from the U.S. Census 8ureau or Desember 23, 2011, nuslear pEWter reaGtor lisensees shall Ele¥elop an ETE analysis using this Elesennial Elata anEI submit it unEler § 50.4 to the NRC. These lisensees shall submit this ETE analysis to the NRC at least 180 Elays before using it to form protesti¥e astion resommenElations anEI pro¥iEling it to State anEI losal go\\*ernmental authorities for use in Ele\\*eloping offsite proteGti¥e aGtion strategies.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Since formal offsite REP plans are not needed, the requirement to have an ETE and to perform an update to the ETE is not needed.

Based on the above analysis and the analysis provided in Section 5.2.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.4, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.5 10 CFR Part 50, Appendix E,Section IV.5 During the years between desennial sensuses, nuslear po>Jfer reaGtor lisensees shall estimate EPZ permanent resiElent population shanges onse a year, but no later than 365 days from the Elate of the pre¥ious estimate, using the most resent U.S. Census 8ureau annual resiElent population estimate anEI State/losal go¥ernment population Elata, if a¥ailable. These lisensees shall maintain these estimates so that they are a¥ailable for NRC inspestion Eluring the period between desennial sensuses anEI shall submit these estimates to the NRC *.vith any updateEI ETE analysis.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Since formal offsite REP plans are not needed, the requirement to have an ETE and to perform an update to the ETE is not needed.

Based on the above analysis and the analysis provided in Section 5.2.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.5, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.6 10 CFR Part 50, Appendix E,Section IV.6 If at any time during the desennial period, the l!PZ permanent resident population iRGreases sush that it sauses the longest 6T6 ¥alue fer the 2 mile zone er 6 mile zone, insluding all affeGted l!mergensy Response Planning Areas, er fer the entire 10 mile l!PZ to insrease hy 26 persent er 30 minutes, t.*thishe¥er is less, from the nuslear power reaGter lisensee's surrently NRC appre¥ed er updated 6T6, the lisensee shall update the 6T6 analysis to refleGt the impaGt of that population insrease. The lisensee shall suhmit the updated 6T6 analysis to the NRC under§ 60.4 no later than 365 days after the lisensee's determination that the sriteria fer updating the 6T6 ha*.*e heen met and at least 180 days hefere using it to form preteGti¥e aGtieR resemmendatiens and pre*Jiding it to State and lesal ge\\*ernmental authorities fer use in developing effsite preteGti*.*e aGtieR strategies.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Since formal offsite REP plans are not needed, the requirement to have an ETE and to perform an update to the ETE is not needed.

Based on the above analysis and the analysis provided in Section 5.2.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.6, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50. 12(a)(2)(ii).

5.2. 7 10 CFR Part 50, Appendix E,Section IV.A.1 A description of the normal plant operating organization.

Since docketing of the certifications of permanent cessation of operations and permanent removal of fuel from the reactor vessel has been completed, the 10 CFR Part 50 license for Oyster Creek no longer authorize operation of the Oyster Creek reactor or emplacement or retention of fuel into the reactor vessel, as specified in 10 CFR 50.82(a)(2). Because the licensee is no longer authorized to operate the reactor, the licensee does not have a plant "operating" organization. A description of the plant organization, as it relates to the requirements in Section IV.A.1 of Appendix E to 10 CFR Part 50 is still required.

Based on the above analysis, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.A 1, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.8 10 CFR Part 50, Appendix E,Section IV.A.3 A Elessription, hy position anEI funGtion to he performeEI, of the lisensee's heaElquarters personnel who will he sent to the plant site to augment the onsite emergensy organization.

The number of staff at decommissioning sites is generally small, but is commensurate with the need to safely store spent fuel at the facility in a manner that is protective of public health and safety. Exelon furnished information concerning its SFP inventory makeup strategies that could be used in the event of a catastrophic loss of SFP water inventory and stated that designated on-shift personnel are trained to implement such strategies with equipment maintained onsite.

Exelon has site personnel designated to respond within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the Alert classification to assist the on-shift staff. As such, designation of specific licensee headquarters personnel is not necessary for the augmentation of the on-shift staffing and, therefore, is not described.

Based on the above analysis and the analysis provided in Section 5.1.1 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.A.3, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provisions of 10 CFR 50.12(a)(2)(ii).

5.2.9 10 CFR Part 50, Appendix E,Section IV.A.4 Identification, by position and function to be performed, of persons within the licensee organization who will be responsible for making effsite dose projections, and a description of how these projections will be made and the results transmitted to State and local authorities, NRC, and other appropriate governmental entities.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. While it is unlikely that a beyond-design-basis event would result in doses in excess of the EPA early phase PAGs to the public beyond the EAB, the licensee still must be able to determine if a radiological release is occurring, thereby achieving the underlying purpose of the rule. If a release is occurring, then the licensee's staff is still required to communicate that information to offsite authorities for their consideration. The offsite authorities are responsible for deciding what, if any, protective actions should be taken that they consider appropriate to protect public health and safety.

Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement for offsite dose projections is not required.

Based on above analysis and the analysis provided in Section 5.1.1 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.A.4, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.10 10 CFR Part 50, Appendix E,Section IV.A.5 ldentifiGatien, by pesitien and funGtien te he perfermed, ef ether empleyees ef the liGensee with speGial qualifiGatiens fer Geping with emergenGy Genditiens that may arise. Other persens with speGial qualifiGatiens, suGh as Gensultants, whe are net empleyees ef the liGensee and whe may he Galled upen fer assistanGe fer emergenGies shall alse he identified. The speGial qualifiGatiens ef these persens shall he desGrihed.

The number of licensee staff at decommissioning sites is generally smaller than that for an operating power reactor, but is still commensurate with the need to operate the facility in a manner that is protective of public health and safety. The NRC staff considered the similarity between the staffing levels at a permanently shut-down and defueled reactor, and staffing levels at an operating power reactor site. The spectrum of accidents at a decommissioning facility is greatly reduced requiring less specialized qualifications. The limited number of systems and equipment needed to maintain the spent fuel in a safe condition in the SFP or in an ISFSI requires only minimal personnel, which is governed by the Oyster Creek TSs.

Exelon furnished information concerning its SFP inventory makeup strategies that could be used in the event of a catastrophic loss of SFP water inventory and stated that designated on-shift personnel are trained to implement such strategies with equipment maintained onsite.

Exelon has site personnel designated to respond within two hours of the Alert classification to assist the on-shift staff. As such, additional employees or other persons with special qualifications are not anticipated.

Considering the very low probability of beyond-design-basis events affecting the SFP, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement for personnel with special qualifications, as directed in 10 CFR Part 50, Appendix E,Section IV.A.5, is not required.

Based on above analysis and the analyses provided in Sections 5.1.1 and 5.2.8 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.A.5, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.11 10 CFR Part 50, Appendix E,Section IV.A. 7 By June 23, 2014, identification of, and a dessriptien ef the assistance expected from, appropriate State, local, and Federal agencies with responsibilities for coping with emergencies, including hestile aGtien at the site.

fer purpeses ef this appendix, "hestile aGtien" is defined as an act directed toward a nuclear power plant or its personnel that includes the use of violent force to destroy equipment, take hostages, and/or intimidate the licensee to achieve an end. This includes attack by air, land, or water using guns, explosives, projectiles, vehicles, or other devices used to deliver destructive force.

In the 2011 EP Final Rule, the Commission defined "hostile action" as, in part, "an act directed toward a nuclear power plant or its personnel." The 2011 EP Final Rule made generically applicable, the security-based response elements of NRC BL 2005-02. The enhancements from NRC BL 2005-02 were applicable to all holders of operating licenses for nuclear power reactors, except those who have permanently ceased operation and have certified that fuel has been removed from the reactor vessel.

With the certifications of 10 CFR 50.82(a)(1), the.10 CFR Part 50 license for Oyster Creek will no longer authorizes operation of the reactor or emplacement or retention of fuel into the reactor vessel, as specified in 10 CFR 50.82(a)(2). Therefore, the enhancements for hostile actions required by the 2011 EP Final Rule are not applicable for Oyster Creek in a permanently shut-down and defueled status.

Although the "hostile action" enhancements in the 2011 EP Final Rule are not applicable to a decommissioning reactor, the licensee's physical security plan must continue to provide high assurance against a potential security event impacting a designated target set. Therefore, some EP requirements for security-based events are maintained, such as the classification of security-based events, notification of offsite authorities, and coordination for the response of OROs (i.e., law enforcement, firefighting, medical assistance) onsite.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.2.1 ol this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.A. 7, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.12 10 CFR Part 50, Appendix E,Section IV.A.8 ldentifisatien ef the State and/er lesal effisials respensible fer planning fer, erdering, and sentrelling apprepriate preteGti¥e aGtiens, insluding e¥aGuatiens when nesessary.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis ~ccident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, identification of the State and/or local officials responsible for planning for, ordering and controlling appropriate offsite protective actions, including evacuations when necessary, is no longer required as part of the Oyster Creek emergency plan. If deemed warranted by governmental officials, offsite protective actions would be implemented under a CEMP, or "all-hazards," process.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.1.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.A.8, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.13 1 O CFR Part 50, Appendix E,Section IV.A.9 8y December 24, 2012, fer nuclear power reactor licensees, a detailed analysis demonstrating that en shift personnel assigned emergency plan implementation functions are net assigned responsibilities that would prei.tent the timely perfermance ef their assigned functions as specified in the emergency plan.

The number of staff required at decommissioning sites is significantly reduced commensurate with the need to safely store spent fuel at the facility in a manner that is protective of public health and safety. The duties of the on-shift personnel at a decommissioning reactor facility are not as complicated and diverse as those for an operating power reactor. The systems and equipment needed to maintain the spent fuel in a safe condition in an SFP or in an ISFSI requires minimal personnel and are governed under the Oyster Creek TSs. In the 2011 EP Final Rule, the NRC required nuclear power plant licensees to provide a detailed analysis to show that on-shift personnel assigned emergency plan implementation functions were not assigned any responsibilities that would prevent them from performing their assigned emergency plan functions. As part of the 2011 EP Final Rule, the NRC concluded that the staffing analysis requirement was not necessary for non-power reactor licensees due to the small staffing levels required to operate the facility. Therefore, based on similarities of non-power reactors and decommissioning reactors with regard to staffing, and as discussed in Section 5.2.1, a detailed staffing analysis is not needed for a decommissioning reactor.

Based on the above analysis, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.A.9, above, is not necessary to achieve the underlying purpose of the rule as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.14 10 CFR Part 50, Appendix E,Section IV.8.1 The means to be used for determining the magnitude of, and for continually assessing the impact of, the release of radioactive materials shall be described, including emergency action levels that are to be used as criteria for determining the need for notification and participation of local and State agencies, the Commission, and other Federal agencies, and the emergency action levels that are to be used for determining when and what type of protective measures should be considered within and eutside the site boundary to protect health and safety. The emergency action levels shall be based on in-plant conditions and instrumentation in addition to onsite and effsite monitoring. 8y June 20 1 20121 fer nuslear pe*i.-ter reaGter lisensees, these aGtien le"i.*els must inslude hestile aGtien that may ad¥ersely affeGt the nuslear pewer plant. The initial emergency action levels shall be discussed and agreed on by the applicant or licensee and State and local governmental authorities, and approved by the NRC. Thereafter, emergency action levels shall be reviewed with the State and local governmental authorities on an annual basis.

The NEI topical report NEI 99-01, Revision 6, "Development of Emergency Action Levels for Non-Passive Reactors," November 2012 (Reference 47), is an acceptable method for development of an EAL scheme for a non-passive operating nuclear power reactor, a permanently defueled power reactor, and an ISFSI. Revision 6 of NEI 99-01 was endorsed by the NRC in a letter dated March 28, 2013 (Reference 48). Since a radiological release from any remaining applicable design-basis accident is not estimated to exceed EPA early phase PAGs beyond the EAB, event classification above the Alert level is no longer required, which is consistent with exemptions for previous decommissioning power reactors. The licensee will still be required to maintain EALs for the classification of security-based events to the Alert level, which was requested by Exelon in a letter dated August 29, 2017 (Reference 49). In the EP Final Rule, the Commission defined "hostile action" as, in part, "an act directed toward a nuclear power plant or its personnel." The 2011 EP Final Rule made generically applicable the security-based response elements of NRC BL 2005-02, which provided numerous enhancements to licensee emergency plans including security-based EALs. The NRC staff is maintaining the requirement for security-based EALs similar to power reactors as they were required by the NRC Order. Exemption from hostile action enhancements for decommissioning reactors was previously discussed in Section 5.2.1 of this safety evaluation.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, a decommissioning reactor is not required to have EALs to determine protective measures offsite. With respect to EALs for hostile action, refer to the basis for 1 O CFR Part 50, Appendix E,Section IV.1.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.2.1 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.B.1, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.15 10 CFR Part 50, Appendix E,Section IV.C.1 The entire spectrum of emergency conditions that involve the alerting or activating of progressively larger segments of the total emergency organization shall be described. The communication steps to be taken to alert or activate emergency personnel under each class of emergency shall be described.

Emergency action levels (based not only on onsite anEI effsite radiation monitoring information but also on readings from a number of sensors that indicate a potential emergency, sush as the pressure in sentainment anEI the respense ef the &mergensy Gere Ceeling System) for notification of offsite agencies shall be described. The existence, but not the details, of a message authentication scheme shall be noted for such agencies. The emergency classes defined shall include: (1) Notification of unusual events, (2) alert, (3) site area emergensy, anEI (4) general emergensy. These classes are further discussed in NUREG-0654/FEMA-REP-1.

Containment and emergency core cooling system parameters no longer provide an indication of a potential emergency for a permanently shut-down and defueled power reactor, and emergency core cooling systems are no longer required. Other available indications, such as SFP level, SFP temperature, and area radiation monitors, will remain at Oyster Creek and will continue to indicate the conditions of spent fuel stored in the SFP.

In the SOC for the Final Rule for EP requirements for ISFSls and for MRS facilities (60 FR 32430; June 22, 1995), the Commission responded to comments concerning a general emergency at an ISFSI and MRS, and concluded, "An essential element of a General Emergency is that [a] release can be reasonably expected to exceed EPA Protective Action Guidelines exposure levels off site for more than the immediate site area. As previously discussed, NRC studies have concluded that the maximum offsite dose would be less than 1 rem [roentgen equivalent man] which is within the EPA Protective Action Guides." The SOC further provides a response to comments concerning an EPZ for an ISFSI and MRS: "[B]ased on the potential inventory of radioactive material, potential driving forces for distributing that amount of radioactive material, and the probability of the initiation of these events, the Commission concludes that the offsite consequences of potential accidents at an ISFSI or a MRS would not warrant establishing Emergency Planning Zones."

Oyster Creek's exemption request provided an analysis that demonstrates that there are no remaining applicable design-basis accidents that would reach the dose criteria for the declaration of a Site Area Emergency or a General Emergency. As discussed previously, the probability of a beyond-design-basis accident condition that could reach emergency classifications of a Site Area Emergency or a General Emergency is very low. In the highly unlikely event of a beyond-design-basis event resulting in the loss of all cooling to spent fuel stored in the SFP, as of 12 months (365 days) after permanent cessation of power operations, it would take at least 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> from the time the fuel is uncovered until it reaches a temperature of 900 *c. The licensee is required to maintain the capability to initiate prompt mitigative actions consistent with plant conditions. Considering the very low probability of beyond-design-basis events occurring that would affect SFP structural integrity, as well as the time available to initiate SFP mitigative measures before the onset of a postulated zirconium cladding fire, an event classification level above an Alert is no longer needed.

Based on the above analysis and the analysis provided in Section 5.1.1 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.C.1, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.16 10 CFR Part 50, Appendix E,Section IV.C.2 8y June 20, 2012, nuGlear poo1er reaGtor licensees shall establish and maintain the capability to assess, classify, and declare an emergency condition

  • .vithin 15 minutes after the availability of indications to plant operators that an emergency action level has been exceeded and shall promptly declare the emergency condition as soon as possible following identification of the appropriate emergency classification level. Licensees shall not construe these criteria as a grace period to attempt to restore plant conditions to avoid declaring an emergency action due to an emergency action level that has been exceeded.

Licensees shall not construe these criteria as preventing implementation of response actions deemed by the licensee to be necessary to protect public health and safety provided that any delay in declaration does not deny the State and local authorities the opportunity to implement measures necessary to protect the public health and safety.

In the 2011 EP Final Rule (76 FR 72560; November 23, 2011 ), nuclear power reactor licensees were required to assess, classify, and declare an emergency condition within 15 minutes.

Non-power reactors do not have the same potential impact on public health and safety as do power reactors, and as such, non-power reactor licensees are not required to establish or maintain complex offsite emergency response activities nor to assess, classify, and declare an emergency condition within 15 minutes. Similarly, a decommissioning power reactor has a lower likelihood of a credible accident resulting in radiological releases requiring offsite protective measures than does an operating power reactor. Unlike operating reactor accident sequences potentially leading to large early releases, accident scenarios at decommissioning plants' SFPs evolve much more slowly and provide a longer time period to initiate SFP mitigative actions or, if warranted by governmental officials, appropriate offsite protective actions for the public. Because a decommissioning power reactor, like a non-power reactor, does not have the same potential radiological impact on public health and safety as a power reactor, the NRC staff concludes that it is not necessary for a decommissioning power reactor licensee to assess, classify and declare an emergency condition within 15 minutes. Oyster Creek proposes in its exemption requests to assess, classify and declare an emergency condition within 30 minutes. The State of New Jersey has agreed that this emergency declaration time is appropriate. The NRC staff finds that 30 minutes to assess, classify and declare an emergency condition is reasonable given the slower progression of a credible event resulting in a radiological release.

Based on the above analysis, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.C.2, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.17 10 CFR Part 50, Appendix E,Section IV.D.1 Administrative and physical means for notifying local, State, and Federal officials and agencies and agreements reaGhed with these offiGials and agenGies for the prompt notifiGation of the publiG and for publiG e¥aGuation or other proteGti¥e measures, should they beGome neGessary, shall be described.

. This description shall include identification of the appropriate offioials, by title and agency, of the State and local government agencies 't.'ithin the EPZs.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirements for prompt notification of the public and an EPZ are not needed.

Based on the above analysis and the analyses provided in Sections 5.1.1, 5.1.2, and 5.1.5 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.D.1, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.18 10 CFR Part 50, Appendix E,Section IV.D.2 Pro¥isions shall be described f:or yearly dissemination to the p1:1blic within the pl1:1me expos1:1re path*Nay EPZ of basic emergency planning information, s1:1ch as the methods and times req1:1ired for p1:1blic notification and the protesti¥e actions planned if an accident oco1:1rs, general inf:ormation as to the nat1:1re and effects of radiation, and a listing of local broadcast stations that will be 1:1sed for dissemination of inf:ormation d1:1ring an emergency. Signs or other meas1:1res shall also be 1:1sed to disseminate to any transient pop1:1lation 'Nithin the pl1:1me expos1:1re path~.*ay EPZ appropriate information that wo1:1ld be helpf1:1I if an aocident ooc1:1rs.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirements for dissemination of emergency planning information to the public and an EPZ are not needed.

Based on the above analysis and the analyses provided in Sections 5.1.1, 5.1.2, and 5.1.5 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.D.2, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.19 10 CFR Part 50, Appendix E,Section IV.D.3 A licensee shall have the capability to notify responsible State and local governmental agencies witRiR 15 minutes after declaring an emergency. 1=he liGensee shall Elemenstrate that the apprepriate gevernmefltal autherities ha*,e the Gapahility te make a puhliG alerting anEI netifiGatien EleGisien premptly en heing infermeEI hy the liGensee ef an emergenGy GenElitien.

Prier te initial eperatien greater than 5 perGent ef rateEI thermal pmter ef the first reaGter at the site, eaGh nuGlear pGtl.*.ter reaGter lieensee shall Elemenstrate that aElministrafr.te anEI physiGal means have heen estahlisheEI fer alerting anEI pre¥iEling prempt instruGtiens te the puhliG with the plume expesure pattF.-.tay EPZ. The Elesign ehjeGtive ef the prempt puhliG alert anEI netifiGatien system shall he te ha¥e the Gapahility te essentially eemplete the initial alerting anEI netifiGatien ef the puhliG within the plume expesure pattF1.tay EPZ within aheut 15 minutes. The use ef this alerting anEI netifiGatien Gapahility will range frem immeEliate alerting anEI netifiGatien ef the puhliG {\\¥ithin 15 minutes ef the time that State anEI leGal effiGials are netifieEI that a situatien exists requiring urgent aGtien} te the mere likely e¥ents where there is suhstantial time awilahle fer the apprepriate gevernmental autherities te make a juElgment *Nhether er net te aGtivate the puhlie alert anEI netifiGatien system. The alerting and netifiGatien Gapahility shall aEIElitienally ineluEle aElministrative anEI physiGal means fer a haGkup metheEI ef puhliG alerting anEI netifiGatien eapahle ef beiRg useEI in the ewnt the primary metheEI ef alerting anEI netifiGatien is una¥ailahle Eluring an emergeney te alert er netify all er pertiens ef the plume expesure pattFNay EPZ pepulatien. The haGkup metheEI shall have the Gapahility te alert anEI netify the puhliG within the plume expesure pathway EPZ, hut Elees net neeEI te meet the 15 minute Elesign ehjeGtive fer the primary prempt puhliG alert anEI netifiGatien system. When there is a EleGisien te aGti*,ate the alert anEI netifiGatien system, the apprepriate gevemmental autherities will Eletermine whether te aGtivate the entire alert anEI netifieatien system simultaneeusly er in a graEluateEI er stageEI manner. The respensihility fer aGti¥ating suGh a puhliG alert anEI netifiGatien system shall remain with the apprepriate ge1+ternmental autherities.

In the permanently shutdown and defueled condition of the reactor, the rapidly developing scenarios associated with events initiated during reactor power operation are no longer credible.

The slow progression of SFP events allows greater time for the licensee to successfully mitigate the accidents and, if necessary, for offsite authorities to implement appropriate protective measures using a CEMP, "all-hazards," approach to protect the health and safety of the public.

Oyster Creek proposes in its exemption requests to complete emergency notifications within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> (60 minutes) after an emergency declaration or a change in emergency classification level. Although Oyster Creek is a general licensed ISFSI and the Oyster Creek Emergency Plan is based on 10 CFR Part 50, the NRC staff considered the requirements in 10 CFR 72.32(a) to ensure consistency between general and specific-licensed ISFSls. The 1-hour notification timeliness is consistent with the notification time requirements for emergency plans based on the requirements in 10 CFR 72.32. Information will be disseminated to the public and media in accordance with State and local plans.

In the SOC for the Final Rule for EP requirements for ISFSls and for MRS facilities (60 FR 32430; June 22, 1995), the Commission responded to comments concerning a notification time of 15 minutes, and concluded that, "[t]he Commission has established a reasonable time limit for notification which has proven to be adequate in the past. The licensee shall also commit to notify the NRC Operations Center immediately after notifications of the appropriate offsite response organizations and not later than one hour after the licensee declares an emergency."'

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. The NRC's research and analysis shows that dec.ommissioning power reactor licensee would have sufficient time to implement mitigation measures consistent with plant conditions and, if necessary, for OROs to initiate protective actions offsite. The NRC staff concludes that notifying OROs as soon as possible and within 60 minutes would not significantly impact the time available for OROs to initiate appropriate response actions. The local Warning Points/Emergency Operations Centers (EOCs) (for Ocean County, Lacey Township and Ocean Township) are notified by the State of New Jersey, as necessary, when an Unusual Event, Alert, or other State EOC notification has been made by the OC Shift Manager. Oyster Creek proposes in its exemption requests to notify the State of New "Jersey of an emergency condition within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> (60 minutes). The State of New Jersey has agreed that this notification time is appropriate. Based on the above analysis, the NRC staff agrees that 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> (60 minutes) to notify the State of an emergency condition is reasonable.

Additionally, the requirements for prompt notification of the public and an EPZ are not needed.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.1.2 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.D.3, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.20 10 CFR Part 50, Appendix E,Section IV.D.4 If FEMA has appre¥ed a nuelear p8t.*ter reaeter site's alert and netifieatien design report, ineluding the haekup alert and netifieatien eapahility, as 8f Deeemher 23, 2011, then the haekup alert and netifieatien eapahility requirements in Seetien l'I.D.3 must he implemented hy Deeemher 24, 2012. If the alert and netifieatien design report does net inelude a haekup a.lert and netifieatien eapahility er needs re*:isien to ensure adequate haekup alert and netifieatien eapahility, then a re¥isien of the alert and netifieatien design report must he suhmitted to FEMA fer re¥iEWt hy June 24, 2013, and the fEMA appre¥ed haekup alert and netifieatien means must he implemented within 365 days after FEMA apprewl. M8t.¥e*:er, the tetal time peried te implement a F6MA appre,1ed haGkYp alert and netif.iGatien means mYst net exGeed Jyne 22, 2015.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirements for prompt notification of the public and an EPZ, including backup alert and notification capabilities, are not needed.

Based on the above analysis and the analysis provided in Section 5.2.19 of this safety evaluation, the NRC staff concludes that the exempted language from 1 O CFR Part 50, Appendix E,Section IV.D.4 above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.21 10 CFR Part 50, Appendix E,Section IV.E.8.a.(i)

A licensee ensite teGhniGal &Yppert Genter and an emergenGy eperatiens facility from which effective direction can be given and effective control can be exercised during an emergency; The guidance in NUREG-0696, "Functional Criteria for Emergency Response Facilities,"

February 1981 (Reference 50), provides that the technical support center (TSC) is an onsite facility located close to the control room that shall provide plant management and technical support to the reactor operating personnel located in the control room during emergency conditions. As there are no remaining applicable design-basis accidents that would exceed the EPA early phase PAGs at the EAB, and available time to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel and before the onset of a postulated zirconium cladding fire, an EOF would not be required to support an offsite agency response. Coordination with offsite authorities and response organizations can.

be coordinated from the control room or another onsite location.

In addition, onsite actions may be directed from the control room or other onsite location, without the requirements imposed on a TSC. Due to the reduced size of on-shift and emergency response organization (ERO) staff for a permanently shut-down and defueled power reactor, separate facilities to accommodate emergency response staff are no longer required.

As such, greater efficiency and coordination is gained by locating staff in a central onsite facility.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.1.3 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.E.8a.(i), above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.22 10 CFR Part 50, Appendix E,Section IV.E.8.a.(ii) fer m.1~lear pewer reaGter liGensees, a liGensee ensite eperatienal suppert Genter; The operational support center (OSC) is an onsite area separate from the control room and the TSC where licensee operations support personnel will assemble in an emergency. The OSC should provide a location where plant logistic support can be coordinated during an emergency and restrict control room access to those support personnel specifically requested by the shift supervisor. The licensee provides that the control room is where plant systems and equipment parameters are monitored. The control room is the onsite center for emergency command and control. Control ro.om personnel assess plant conditions, evaluate the magnitude and potential consequences of abnormal conditions, initiate preventative, mitigating, and corrective actions and perform notifications.

With the permanently shut-down and defueled status of the Oyster Creek reactor and the storage of the spent fuel in the SFP and the ISFSI, an OSC will no longer be required to meet its original purpose during an emergency, nor to support initial SFP mitigation actions if needed.

When activated, the ERO reports to the Emergency Director to assist the on-shift staff in the assessment, mitigation, and response to an emergency and to support the dispatch of emergency teams. An onsite facility will continue to be maintained, from which effective direction can be given and effective control may be exercised during an emergency.

Based on the above analysis and the analysis provided in Section 5.2.21 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.A.8.a.(ii), above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.23 10 CFR Part 50, Appendix E,Section IV.E.8.b.

fer a RUGlear pe,>>er reaGter liGensee's emergenGy eperatiens faGility required hy paragraph 8.a ef this seGtieR, either a faGility leGated het\\'!een 10 miles and 25 miles ef the RUGlear p8'.'ter reaGter site(s), er a primary faGility leGated less than 10 miles frem the RUGlear pewer reaGter site(s) and a haGkup faGility leGated hea,*een 10 miles and 25 miles ef the Rl:IGlear p8'>>er reaGter site(s). AR emergenGy eperatiens faGility may seF\\'e mere than ene nuGlear pewer reaGter site. A liGensee desiring te leGate an emergenGy eperatiens faGility mere than 25 miles frem a nuGlear pewer reaGter site shall request prier Cemmissien appre¥al hy suhmitting an appliGatien fer an amendment te its liGense. Fer an emergenGy eperatiens faGility leGated mere than 25 miles frem a RUGlear p8\\'fer reaGter site, pre¥isiens must he made fer leGating NRC and effsite respenders Gieser te the-RUGlear pe,Ner reaGter site se that NRC and effsite respenders san interaGt faGe te faGe *Nith emergensy respense persennel entering and lea¥ing the RUGlear pewer reaGter site. Pre¥isiens fer leGating NRC and effsite respenders Gieser te a RUGlear p8'Ner reaGter site that is mere than 25 miles frem the emergenGy eperatiens faGility must iRGlude the fell8'Ning:

(1)

(2)

(3)

(4)

(5) Space for members of an NRC site team and Federal, State, and local responders; Additional space for conducting briefings with emergency response personnel; Communication with other licensee and offsite emergency response facilities; Access to plant data and radiological information; and Access to copying equipment and office supplies; Based on the analyses provided in Sections 5.1.1 and 5.1.3 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.A.8.b, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.24 10 CFR Part 50, Appendix E,Section IV.E.8.c.

8y June 20, 2012, for a nuclear pe>tNer reactor licensee's emergency operations facility required by paragraph 8.a of this section, a facility ha*.*ing the following capabilities:

(1)

(2)

(3)

The capability for obtaining and displaying plant data and radiological information for each reactor at a nuclear p0t11er reactor site and for each nuclear pm'fer reactor site that the facility serves; The capability to analyze plant technical information and provide technical briefings on event conditions and prognosis to licensee and offsite response organizations for each reactor at a nuclear pe>tNer reactor site and for each nuclear pe>tNer reactor site that the facility serves; and The oapability to support response to e*.*ents occurring simultaneously at more than one nuclear po>J.*er reactor site if the emergency operations facility serves more than one site; and Based on the analyses provided in Sections 5.1.1 and 5.1.3 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.E.8.c, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.25 10 CFR Part 50, Appendix E,Section IV.E.8.d.

For nuclear pm*.*er reactor licensees, an alternative facility (or facilities) that would be accessible even if the site is under threat of or experiencing hostile action, to function as a staging area for augmentation of emergency response staff and collectively having the following characteristics: the sapahility fer semmunisatien with the emergensy eperatiens fasility, sentrel reem, am:I plant sesurity; the sapahility te perferm effsite netif.isatiens; am:I the sapahility fer engineering assessment aGti\\*ities, insluEling Elamage sentrel team planning anEI preparatien, fer use when ensite emergensy fasilities Gannet he safely assesseEI Eluring hestile aGtien. The requirements in this paragraph 8.EI must he implementeEI ne later than Desemher 23, 2014, *.tJith the e>c:septien ef the sapahility fer staging emergensy respense erganizatien persennel at the alternati*.-e fasility (er fasilities) anEI the sapahility fer semmunisatiens *A*ith the emergensy eperatiens fasilit)*, sentrel ream, anEI plant sesurity, *.*.rhish must he implementeEI ne later than June 20, 2012.

Based on the analyses provided in Sections 5.1.1, 5.2.1, and 5.2.11 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,

,Section IV.E.8.d, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.26 10 CFR Part 50, Appendix E,Section IV.E.8.e.

A lisensee shall net he suhjest te the requirements ef paragraph 8.h ef this seGtien fer an e>c:isting emergensy eperatiens fasility appre¥eEI as ef Desemher 23, 2011; Based on the analyses provided in Sections 5.1.3 and 5.2.21 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.E.8.e, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.27 10 CFR Part 50, Appendix E,Section IV.E.9.a Provision for communications with contiguous State/local governments within the plume e>c:pesure pathway &PZ. Such communications shall be tested monthly.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after the final reactor shutdown, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, provisions for communications with contiguous State/local governments within the plume exposure pathway EPZ are not needed. Oyster Creek proposes in its exemption requests to complete emergency notifications within one hour after an emergency declaration or a change in emergency classification level. Communications systems will be maintained and tested monthly.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.1.2 of this safety evaluation, the NRC staff concludes that the exempted language from Section IV.E.9 to Appendix E of 10 CFR Part 50 Appendix E,Section IV.E.9.a, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.28 10 CFR Part 50, Appendix E,Section IV.E.9.c.

Provision f-Or GommuniGations among the nuGlear p0tNer reaotor Gontrol room, the onsite teGhniGal support Genter, and the emergenGy operations faGility, and among the nuGlear faGility, the prinGipal State and loGal emergenGy operations Genters, and the field assessment teams. SuGh GommuniGations systems shall be tested annually.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, as discussed in Sections 5.2.21 and 5.2.22 of this safety evaluation, there is no need for a TSC, EOF, or offsite field assessment teams to meet the underlying purpose of the rule. With the elimination of the requirements for a TSC, EOF, and the field assessment teams, the requirements to perform annual testing is no longer required.

Based on the above analysis and the analyses provided in Sections 5.2.21 and 5.2.22 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.E.9.c, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.29 10 CFR Part 50, Appendix E,Section IV.E.9.d.

Provisions for communications by the licensee with NRC Headquarters and the appropriate NRC Regional Office Operations Center from the nuGlear po'JJer reaotor Gontrol room, the onsite teGhniGal support Genter, and the near site emergenGy operations facility. Such communications shall be tested monthly.

As discussed in Section 5.2.21 and 5.2.22 of this safety evaluation, the need for a separate TSC and EOF no longer exists given the smaller facility staffing and the greatly reduced required interaction with State and local emergency response facilities. The NRC staff concludes that the functions of the control-room, EOF, TSC, and the OSC may be combined into one or more locations. As a result, communications between the EOF and TSC, and the NRC, and monthly testing of these capabilities are no longer needed. Communications with NRC Headquarters and the appropriate NRC Regional Office Operations Center will continue to be tested monthly.

Based on the above analysis and the analyses provided in Sections 5.2.21 and 5.2.22 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.E.9.d, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after the certification of the permanent operations has been docketed and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.30 10 CFR Part 50, Appendix E,Section IV.F.1 The program to provide for: (a) The training of employees and exercising, by periodic drills, of radiation emergency plans to ensure that employees of the licensee are familiar with their specific emergency response duties, and (b) the participation in the training and drills by other persons whose assistance may be needed in the event of a radiation emergency shall be described. This shall include a description of specialized initial training and periodic retraining programs to be provided to each of the following categories of emergency personnel:

i.

Directors and/or coordinators of the plant emergency organization; ii.

Personnel responsible for accident assessment, including control room shift personnel; iii.

Radiological monitoring teams; iv.

Fire control teams (fire brigades);

v.

Repair and damage control teams; vi.

First aid and rescue teams; vii.

Medical support personnel;

¥iii.

licensee's heaElquarters support personnel; ix.

Security personnel.

In addition, a radiological orientation training program shall be made available to local services personnel; e.g., local emergency services/Ci¥il Defense, local law enforcement personnel, local news meElia peFsons.

The number of staff required at decommissioning sites is generally small, but is commensurate with the need to safely store spent fuel at the facility in a manner that ensures public health and safety. Decommissioning sites typically have a level of emergency response that does not require additional response by licensee headquarters personnel, therefore training of these personnel is not needed. Training for licensee personnel responding from company locations offsite will still be required based on ERO positions specified above.

"Civil Defense" is an outdated term and no longer used. The category of offsite responders, which could be expected to respond onsite, is captured under "local emergency services" and "local law enforcement." Local news media are not included in the category of local services personnel requiring periodic radiological orientation training since they will not be called upon to support the formal Joint Information Center.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.2.8 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.F.1, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.31 10 CFR Part 50, Appendix E,Section IV.F.2 The plan shall describe provisions for the conduct of emergency preparedness exercises as follows: Exercises shall test the adequacy of timing and content of implementing procedures and methods, test emergency equipment and communications networks, test the puhliG alert and notifisation sy,stem, and ensure that emergency organization personnel are familiar with their duties.

Based on the analyses provided in Sections 5.1.1 and 5.2.19 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.F.2, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.32 10 CFR Part 50, Appendix E,Section IV.F.2.a.

A full partisipation exeroise *.tfhish tests as mush of the lisensee, State, and losal emergensy plans as is reasonahly ashie*"'ahle without mandatory puhlis partisipation shall he sonduGted for eash site at *.tfhish a pcn¥er

. reastor is losated. Nuslear po*Ner reaGtor lisensees shall suhmit exersise ssenarios under§ 50.4 at least 60 days hefore use in a full partisipation exeroise required hy this paragraph 2.a.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement to conduct a full participation exercise with State and local agencies is not needed. Oyster Creek proposes in its exemption requests to continue to invite the State of New Jersey and local support to participate in the periodic drills and exercise conducted at Oyster Creek.

Based on above analysis and the analysis provided in Section 5.1.1 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.F.2.a, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.33 10 CFR Part 50, Appendix E,Section IV.F.2.b.

Each licensee at each site shall conduct a subsequent exercise of its onsite emergency plan every 2 years. Nuolear power reaotor lioeRsees shall submit exeroise soeRarios uRder § 50.4 at least 60 days before use in an exeroise required by this paragraph 2.b. The exeroise may be iRoluded in the full partioipation biennial exeroise required by paragraph 2.o. of this seotion. In addition, the licensee shall take actions necessary to ensure that adequate emergency response capabilities are maintained during the interval between biennial exercises by conducting drills, including at least one drill involving a combination of some of the principal functional areas of the licensee's onsite emergency response capabilities. The principal functional areas of emergency _

response include activities such as management and coordination of emergency response, accident assessment, event classification, notification of offsite authorities, assessment of the onsite and offsite impact of radiological releases, proteotive aotioR reoommeRdation development, proteotive aotion deoision makiRg, plant system repair and mitigative action implementation. During these drills, activation of all of the licensee's emergency response facilities (TeohRioal Support CeRter (TSC), Operations Support Center (OSC), and the Emergenoy Operations Faoility (EOF)) would not be necessary, licensees would have the opportunity to consider accident management strategies, supervised instruction would be permitted, operating staff in all participating facilities would have the opportunity to resolve problems (success paths) rather than have controllers intervene, and the drills may focus on the onsite exercise training objectives.

The intent of submitting exercise scenarios at an operating power reactor site in advance is to check that licensees utilize different scenarios in order to prevent the preconditioning of responders at power reactors. For decommissioning power reactor sites, there are limited events that could occur, and as such, the submittal of exercise scenarios for the purpose of ensuring that responders do not get preconditioned to certain scenarios is not necessary to achieve the underlying purpose of the rule.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, drills involving principle functional areas associated with formal offsite REP are not needed. As discussed previously in Sections 5.2.21 and 5.2.22 of this safety evaluation, there is no need for an OSC, TSC, or EOF to meet the underlying purpose of the rule.

Based on the above analysis and the analyses provided in Sections 5.1.1, 5.2.21, 5.2.22, and 5.2.32 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.F.2.b, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.34 10 CFR Part 50, Appendix E,Section IV.F.2.c.

Offsite plans fer eash site shall be eJCeFGised biennially with full partisipatien by eash effsite autherity ha¥ing a rele under the radielegisal respense plan. ¥.'here the effsite autherity has a rele under a radielegisal respense plan fer mere than ene site, it shall fl:llly partisipate in ene eJCersise e¥ery twe years and shall, at least, partially partisipate in ether effsite plan eJCersises in this peried. If twe different lisensees east. ha¥e lisensed fasilities lesated either en the same site er en adjasent, sentigueus sites, and share mest ef the elements defining se lesated lisensees, then east. lisensee shall:

(1) Cendust an eJCeFGise biennially ef its ensite emergensy plan; (2) Partisipate quadrennially in an effsite biennial full er partial partisipatien eKersise; (3) CenduGt emergensy preparedness asti¥ities and interaGtiens in the years bet\\.'.'een its partisipatien in the effsite full er partial partisipatien eKersise with effsite autherities, te test and maintain interfase ameng the affeGted State and lesal autherities and the lisensee. Ce lesated lisensees shall alse partisipate in emergensy preparedness aGti¥ities and interaGtien ~Nitti effsite autherities fer the peried bet\\.'leen eKeFGises; (4) CenduGt a hestile aGtien eJCersise ef its ensite emergensy plan in eash eJCersise sysle; and (5) Partisipate in an effsite biennial full er partial partisipatien hestile aGtien eK~rsise in alternating eJCersise sysles.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement to conduct a full participation exercise with State and local agencies is not needed.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.2.32 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.F.2.c, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.35 10 CFR Part 50, Appendix E,Section IV.F.2.d.

Eaoh State with re,spensibility fer nuolear p8\\ver reaoter emergenoy preparedness sheuld fully partioipate in the ingestien pathway pertien ef exeroises at least enoe e'.'ery exeroise oyole. In States with mere than ene nuolear p8'>>er reaoter plume expesure pathway EPZ, the State sheuld retate this partioipatien frem site te site. Eaoh State with respensibility fer nuolear p8'Ner reaoter emergenoy preparedness sheuld fully partioipate in a hestile aotien exeroise at least enoe e'.'ery oyole and sheuld fully partioipate in ene hestile aotien exeroise by Deoember 31, 2015. States with mere than ene nuolear p8'l.*Jer reaoter plume expesure pathway EPZ sheuld retate this partioipatien frem site te site.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after the final reactor shutdown, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) are not needed. Therefore, the requirement to ensure that the State fully participate in the ingestion pathway portion of the exercise is not needed.

Additionally, the NRC excluded non-power reactors from the definition of "hostile action" at the time of the 2011 EP Final Rule because, as defined in 10 CFR 50.2, a non-power reactor is not considered a nuclear power reactor and a regulatory basis had not been developed to support the inclusion of non-power reactors in the definition of "hostile action." Similarly, a decommissioning power reactor or ISFSI is not a "nuclear reactor as defined in the NRC's regulations. Like a non-power reactor, a decommissioning nuclear reactor also has a lower likelihood of a credible accident resulting in radiological releases requiring offsite protective measures than does an operating nuclear reactor. For all of the above reasons, the NRC staff concludes that a decommissioning nuclear power reactor is not a facility that falls within the definition of "hostile action."

Based on the above analysis and the analyses provided in Sections 5.1.1, 5.2.1, and 5.2.32 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.F.2.d, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.36 10 CFR Part 50, Appendix E,Section IV.F.2.e.

Licensees shall enable any State or local Government leoated '."i.'ithin the plume expesure pathway EPZ to participate in the licensee's drills when requested by such State or local Government.

Oyster Creek's exemption request provided an analysis to show that, as of 33 days after permanent cessation of power operations, the radiological consequences to the public of the only remaining applicable design-basis accident would not exceed the limits of the EPA early phase PAGs beyond the EAB. Considering the very low probability of beyond-design-basis events affecting the SFP integrity, and with the time available to initiate mitigative actions consistent with plant conditions, between the loss of both water and air cooling to the spent fuel, and before the onset of a postulated zirconium cladding fire, formal offsite REP plans (in accordance with 44 CFR Part 350) and their associated EPZs are not needed. Therefore, identifying State and local Governments in relation to a plume exposure pathway EPZ is not needed.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.1.2 of this safety evaluation, the NRC staff concludes that the exempted language from 1 O CFR Part 50, Appendix E,Section IV.F.2.e, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.37 10 CFR Part 50, Appendix E,Section IV.F.2.f.

Remedial exercises will be required if the emergency plan is not satisfactorily tested during the biennial exercise, such that NRC, iR G8RsultatieR *..-:ith FliMA, cannot (1) find reasonable assurance that adequate protective measures can and will be taken in the event of a radiological emergency or (2) determine that the Emergency Response Organization (ERO) has maintained key skills specific to emergency response. The eldeRt ef State aRd leGal partiGipatieR iR remedial eJC.erGises must be suffiGieRt te shEW.* that appropriate GorreGtive measures ha11e heeR takeR regardiRg the elemeRts ef the plaR Rot properly tested iR the previeus eJC.erGises.

As discussed previously in Section 5.2.32, the requirement to conduct a full participation exercise with State and local agencies is not needed. Since full participation emergency plan exercises are not required and FEMA does not have responsibilities related to onsite emergency preparedness, NRC consultation with FEMA is not necessary.

Based on the above analysis and the analyses provided in Sections 5.1.1 and 5.2.32 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.F.2.f, above is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.38 10 CFR Part 50, Appendix E,Section IV.F.2.i.

Ucensees shall use drill and exercise scenarios that provide reasonable assurance that anticipatory responses will not result from preconditioning of participants. SuGh sGeRaries fer RUGlear pO'l."§er reaGter liGeRsees must iRGlude a wide speGtrum ef radielegiGal releases aRd eveRts, iRGludiRg hestile aGtioR. Exercise and drill scenarios as appropriate must emphasize coordination among onsite and offsite response organizations.

The NRC staff previously evaluated the issues of preconditioning drill scenarios and including hostile action scenarios at decommissioning plants in Section 5.2.32 and Section 5.2.1, respectively, of this safety evaluation. In each instance, the NRC staff concluded that the exempted words were not needed to achieve the underlying purpose of this requirement as it applies to Oyster Creek and, therefore, meets the special circumstances provisions of 10 CFR 50.12(a)(2)(ii).

Based on the above analysis and the analyses provided in Sections 5.1.1, 5.2.1, and 5.2.32 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.F.2.i, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.39 10 CFR Part 50, Appendix E,Section IV.F.2.j.

The exerGises GOREh:1Gted uRder paragraph 2 of this seGtioR hy RuGlear power reaGtor liGeR&ees must provide the opportuRity for the ERO to demoR&trate profiGieRGy iR the key skills ReGe&sary to implemeRt the priRGipal fuRGtioRal areas of emergeRGy respoR&e ideRtified iR paragraph 2.h of this seGtioR. Eash exerGi&e must pro>.Jide the opportuRity for the liRO to demoRstrate key skills spesifiG to emergeRGy respoR&e duties iR the GoRtrol room, TSC, OSC, EOF, aRd joiRt iRformatioR GeRter.

AaditioRally, iR eash eight saleRdar year exersise Gysle, RUGlear power reaGtor liGeRsees shall vary the GORteRt of sGeRarios duriRg exerGises GoRduGted uRder paragraph 2 of this seGtioR to provide the opportuRity foF the ERO to demoRstrate profiGieRGy iR the key skills ReGe&sary to respoRd to the follO'>>iRg &GeRario elemeRt&: hostile aGtioR direGted at the plaRt site, RO radiologisal release or aR uRplaRRed miRimal radiologiGal release that does Rot require puhliG proteGtive aGtioR&, aR iRitial slassifisatioR of or rapid essalatioR to a Site A"'ea EmergeRGy or GeReral EmergeRGy, implemeRtatioR of strategies, proGedures, aRd guidaRGe developed uRder

§ 50.54(hh)(2), aRd iRtegratiOR of offsite re&OUFGe& >."Jith OR&ite respoR&e.

The liseRsee shall maiRtaiR a resord of exerGises GORduGted duriRg eash eight year exersise syGle that dosumeRts the GORteRt of &GeRarios used to Gomply with the requiremeRt& of this paragraph. EaGh liGeR&ee shall GORduGt a hostile aGtioR exersise for eaGh of its sites RO later thaR Desemher 31, 2015. The first eight year exerGise GyGle for a site 'Nill hegiR iR the GaleRdar year iR whish the first hostile aGtioR exersise is GoRduGted.

for a site liseRsed under Part 52, the first eight year exersise GyGle hegins iR the saleRdar year of the initial exerGi&e required hy SeGtion IV.f.2.a.

In the SOC for the 2011 EP Final Rule, the NRC discussed the addition of a new Section IV.F.2.j to Appendix E to require all nuclear power reactor licensees to provide an opportunity for the ERO to demonstrate proficiency in response to a wide spectrum of scenarios1 including a "hostile action" and a loss of large areas of the plant due to fire or explosion; The NRC staff previously evaluated the need for hostile action enhancements in Section 5.2.1 of this safety evaluation.Section IV.F.2.j further provides that the ERO must demonstrate key skills specific to emergency response duties in the control room, TSC, OSC, EOF, and joint information center. The NRC staff previously concluded that the functions of the control room, EOF, TSC, and the OSC may be combined into one or more locations in Sections 5.2.21, 5.2.22, and 5.2.29 of this safety evaluation. A dedicated joint information center is also not needed based on the analysis in Section 5.2.30 of this safety evaluation. At a decommissioning site, where only the SFP and its related support systems, structures, and components remain, there are no other facilities in which ERO personnel could demonstrate proficiency.

Based on the above analysis and the analyses provided in Sections 5.1.1, 5.2.1, and 5.2.33 of this safety evaluation, the NRC staff concludes that the exempted language from 10 CFR Part 50, Appendix E,Section IV.F.2.j, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

5.2.40 10 CFR Part 50, Appendix E,Section IV. I.

8y June 20, 2012, fer nuslear pewer reaGter lisensees, a range ef pretestive astiens te pretest ensite persennel Eluring hestile aGtien must he ElevelepeEI te ensure the sentinueEI ahility ef the lisensee te safely shut El8'.'ln the reaGter anEI perferm the fl:lnGtiens ef the lisensee's emergensy

~

Based on the analysis provided in Section 5.2.1 of this safety evaluation, the NRC staff concludes that the enhancements for hostile actions, as required by the 2011 EP Final Rule, are not necessary for Oyster Creek in its permanently shut down and defueled status. Therefore, the exempted language from 10 CFR Part 50, Appendix E,Section IV.I, above, is not necessary to achieve the underlying purpose of this requirement as it applies to Oyster Creek 12 months (365 days) after permanent cessation of power operations and, therefore, meets the special circumstances provision of 10 CFR 50.12(a)(2)(ii).

6.0 ENVIRONMENTAL CONSIDERATION

S In accordance with 10 CFR 51.31(a), the Commission has determined that the granting of this exemption will not have a significant effect on the quality of the human environment as discussed in the NRC staff's Finding of No Significant Impact and associated Environmental Assessment published in the Federal Register on August 13, 2018 (83 FR 40092).

7.0 CONCLUSION

The NRC staff has completed its review of the licensee's request for an exemption from certain requirements of 10 CFR 50.47(b), 10 CFR 50.47(c), and Appendix E to 10 CFR Part 50, as specified in this safety evaluation. On the basis of its review, the NRC staff concludes that the postulated dose to the general public from any remaining applicable design-basis accident would not exceed the EPA early phase PAG limits at the EABs and, for any highly unlikely beyond-design-basis events impacting SFP integrity or the ability to cool spent fuel, the length of time available to implement pre-planned mitigation measures consistent with plant conditions and, if necessary, for offsite authorities to implement protective actions using a CEMP, "all-hazards," approach, provides confidence that offsite measures for the public could be taken without preplanning. The conclusion is consistent with the staff's evaluation, as provided to the Commission in SECY-18-0062 (Reference 32), which was approved by the Commission in the SRM to SECY-18-0062 (Reference 33).

Accordingly, the NRC staff has determined that, pursuant to 10 CFR 50.12(a), the exemptions evaluated above are authorized by law, will not present an undue risk to the public health and safety, and are be consistent with the common defense and security. Also, special circumstances are present. Specifically, the NRC staff finds that with the licensee's requested exemptions meet the underlying purpose of the planning standards in 10 CFR 50.47 and requirements in Appendix E to 10 CFR Part 50 in view of the reduced risk of offsite radiological consequences associated.with a permanently shut down and defueled condition at Oyster Creek and therefore, satisfy the special circumstances in 10 CFR 50.12(a)(2)(ii) and can be implemented at 12 months (365 days) after permanent cessation of power operations (Reference 51 ).

8.0 REFERENCES

1.

Jury, K. R., Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "Permanent Cessation of Operations at Oyster Creek Nuclear Generating Station," dated January 7, 2011 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML110070507).

2.

Gallagher, M. P., Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "Certification of Permanent Cessation of Power Operations for Oyster Creek Nuclear Generating Station," dated February 14, 2018 (ADAMS Accession No. ML18045A084).

3.

Gallagher, M. P., Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "Request for Exemptions from Portions of 10 CFR 50.47 and 10 CFR Part 50, Appendix E," dated August 22, 2017 (ADAMS Accession No. ML17234A082).

4.

Gallagher, M. P., Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "Response to Request for Additional Information (RAI) Regarding Request for Exemption from Portions of 10 CFR 50.47 and 10 CFR Part 50, Appendix E," dated December 6, 2017 (ADAMS Accession No. ML17340A708).

5.

Gallagher, M. P., Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "Supplement to Request for Exemption from Portions of 10 CFR 50.47 and 1 O CFR Part 50, Appendix E," dated January 23, 2018 (ADAMS Accession No. ML18023A138).

6.

Gallagher, M. P., Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "Supplement to Request for Exemption from Portions of 1 O CFR 50.47 and 1 O CFR Part 50, Appendix E," dated March 8, 2018 (ADAMS Accession No. ML18067A087).

7.

Gallagher, M. P., Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "Response to Request for Additional Information (RAI) Related to Exemption Request from Portions of 10 CFR 50.47 and 10 CFR Part 50, Appendix E,"

dated March 19, 2018 (ADAMS Accession No. ML18078A146).

8.

Wengert, T. J., U.S. Nuclear Regulatory Commission, letter to David Heacock, Dominion Energy Kewaunee, Inc., "Kewaunee Power Station - Exemptions from Certain Emergency Planning Requirements and Related Safety Evaluation {TAC No. MF2567),"

dated October 27, 2014 (ADAMS Accession No. ML14261A223).

9.

Orenak, M. D., U.S. Nuclear Regulatory Commission, letter to Terry D. Hobbs, Crystal River Nuclear Plant, "Crystal River Unit 3 - Exemptions from Certain Em'ergency

10.

Wengert, T. J., U.S. Nuclear Regulatory Commission, letter to Thomas J. Palmisano, Southern California Edison Company, "San Onofre Nuclear Generating Station, Units 1, 2, and 3, and Independent Spent fuel Storage Installation - Exemptions from Certain Emergency Planning Requirements and Related Safety Evaluation (TAC Nos. MF3835, MF3836, and MF3837)," dated June 4, 2015 (ADAMS Accession No. ML15082A204).

11.

Kim, J., U.S. Nuclear Regulatory Commission, letter to Site Vice President, Entergy Nuclear Operations, Inc., "Vermont Yankee Nuclear Power Station - Exemptions From Certain Emergency Planning Requirements and Related Safety Evaluation (CAC No. MF3614)," dated December 10, 2015 (ADAMS Accession No. ML15180A054).

12.

Kim, J., U.S. Nuclear Regulatory Commission, letter to Mary J. Fisher, Omaha Public Power District, "Fort Calhoun Station, Unit No. 1 - Exemptions From Certain Emergency Planning Requirements and Related Safety Evaluation (CAC No. MF9067; EPID L-2016-LLE-0003)," dated December 11, 2017 (ADAMS Accession No. ML17263B198).

13.

U.S. Nuclear Regulatory Commission, NUREG-1738, "Technical Study of Spent Fuel Pool Accident Risk at Decommissioning Nuclear Power Plants," February 2001 (ADAMS Accession No. ML010430066).

14.

U.S. Nuclear Regulatory Commission, SECY-01-0100, "Policy Issues Related to Safeguards, Insurance, and Emergency Preparedness Regulations at Decommissioning Nuclear Power Plants Storing Fuel in Spent Fuel Pools," dated June 4, 2001 (ADAMS Accession No. ML011450420).

15.

U.S. Environmental Protection Agency (EPA), EPA 400-R 92-001, "Manual of Protective Action Guides and Protective Actions for Nuclear Incidents," October 1991 (reprinted May 1992).

16.

Federal Emergency Management Agency's Comprehensive Preparedness Guide 101, "Developing and Maintaining Emergency Operations Plans," Version 2.0, November 2010 (http://www.fema.gov/pdf/abouUdivisions/npd/CPG 101 V2.pdf).

17.

U.S. Nuclear Regulatory Commission, NUREG/CR-6451, "A Safety and Regulatory Assessment of Generic BWR and PWR Permanently Shutdown Nuclear Power Plants,"

August 1997 (ADAMS Accession No. ML082260098).

18.

U.S. Nuclear Regulatory Commission, NUREG-2161, "Consequence Study of a Beyond-Design-Basis Earthquake Affecting the Spent Fuel Pool for a U.S. Mark I Boiling Water Reactor," September 2014 (ADAMS Accession No. ML14255A365).

19.

U.S. Nuclear Regulatory Commission, COMSECY-13-0030, "Staff Evaluation and Recommendation for Japan Lessons-Learned Tier 3 Issue on Expedited Transfer of Spent Fuel," dated November 12, 2013 (ADAMS Accession No. ML13329A918).

20.

U.S. Nuclear Regulatory Commission, SRM-COMSECY-13-0030, "Staff Requirements -

COMSECY-13-0030 - Staff Evaluation and Recommendation for Japan Lessons-Learned Tier 3 Issue on Expedited Transfer of Spent Fuel," dated May 23, 2014 (ADAMS Accession No. ML14143A360).

21.

Weber, M. F., memorandum to Brian E. Holian, U.S. Nuclear Regulatory Commission, "Transmittal of Reports to Inform Decommissioning Plant Rulemaking for User Need Request NSIR-2015-001," dated May 31, 2016 (ADAMS Accession No. ML16110A416).

22.

U.S. Nuclear Regulatory Commission, Order EA-02-026, "Order Modifying Licenses,"

dated February 25, 2002 (ADAMS Accession No. ML020510635).

23.

Borchardt, R. W., memorandum to Commission, U.S. Nuclear Regulatory Commission, "Documentation of Evolution of Security Requirements at Commercial Nuclear Power Plants with Respect to Mitigation Measures for Large Fires and Explosions," dated February 4, 2010 (ADAMS Accession No. ML092990438).

24.

Nuclear Energy Institute, NEI 06-12, "B.5.b Phase 2 & 3 Submittal Guideline,"

Revision 2, December 2006 (ADAMS Accession No. ML070090060).

25.

Dyer, J. E., U.S. Nuclear Regulatory Commission, letter to Anthony Pietrangelo, Nuclear Energy Institute, endorsing NEI 06-12, "B5.b Phases 2 & 3 Submittal Guideline," dated December 22, 2006 (not publicly available; security-related information).

26.

U.S. Nuclear Regulatory Commission, Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events," dated March 12, 2012 (ADAMS Accession No. ML12054A735).

27.

U.S. Nuclear Regulatory Commission, Order EA-12-051, "Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation," dated March 12, 2012 (ADAMS Accession No. ML12054A679).

28.

U.S. Nuclear Regulatory Commission, Office of Nuclear Security and Incident Response (NSIR), Division of Preparedness and Response (DPR), Interim Staff Guidance (ISG) document NSIR/DPR-ISG-02, "Emergency Planning Exemption Requests for Decommissioning Nuclear Power Plants," dated May 11, 2015 (ADAMS Accession No. ML14106A057).

29.

U.S. Department of Homeland Security/Federal Emergency Management Agency and U.S. Nuclear Regulatory Commission, "Memorandum of Understanding Between the Department of Homeland Security/Federal Emergency Management Agency and Nuclear Regulatory Commission Regarding Radiological Emergency Response, Planning, and Preparedness," dated December 5, 2017 (ADAMS Accession No. ML15344A371 ).

30.

Scott, M. L., U.S. Nuclear Regulatory Commission, letter to Hampton H. Hart, Federal Emergency Management Agency, "Proposed Commission Paper Language for the Oyster Creek Nuclear Generating Station Emergency Plan Decommissioning Exemption Request," dated March 9, 2018 (ADAMS Accession No. ML18032A656).

31.

Casey, M., Federal Emergency Management Agency, letter to Michael Scott, U.S. Nuclear Regulatory Commission, "Proposed Commission Paper Language for the Oyster Creek Nuclear Generating Station Emergency Plan Decommissioning Exemption Request," dated April 2, 2018 (ADAMS Accession No. ML18093A071).

32.

U.S. Nuclear Regulatory Commission, SECY-18-0062, "Request by the Exelon Generation Company, LLC for Exemptions from Certain Emergency Planning Requirements for the Oyster Creek Nuclear Generating Station," dated May 31, 2018 (ADAMS Accession No. ML180308359).

33.

U.S. Nuclear Regulatory Commission, "Staff Requirements - SECY-18-0062, Request by the Exelon Generation Company, LLC for Exemptions from Certain Emergency Planning Requirements for the Oyster Creek Nuclear Generating Station," dated July 17, 2018 (ADAMS Accession No. ML18198A449).

34.

Scaletti, D., U.S. Nuclear Regulatory Commission, letter to Oliver D. Kingsley, Commonwealth Edison Company, "Request for Approval of Defueled Station Emergency Plan and Exemption from Certain Requirements of 10 CFR 50.47, 'Emergency Plans' -

Zion Nuclear Power Station, Units Nos. 1 and 2 (TAC Nos. MA5253 and MA5254),"

dated August 31, 1999 (ADAMS Accession No. ML17227A235).

35.

U.S. Nuclear Regulatory Commission, NUREG-0396 (EPA 520/1-78-016), "Planning Basis for the Development of State and Local Government Radiological Emergency Response Plans in Support of Light Water Nuclear Power Plants," December 1978 (ADAMS Accession No. ML051390356).

36.

U.S. Nuclear Regulatory Commission, "Spent Fuel Project Office Interim Staff Guidance-16, Emergency Planning," dated June 14, 2000 (ADAMS Accession No. ML003724570).

37.

Hendricks, L., Nuclear Energy Institute, letter to the U.S. Nuclear Regulatory Commission transmitting industry commitments, dated November 12, 1999 (ADAMS Accession No. ML993340413).

38.

U.S. Nuclear Regulatory Commission, Regulatory Guide 1.174, Revision 2, "An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis," May 2011 (ADAMS Accession No. ML100910006).

39.

U.S. Nuclear Regulatory Commission, Regulatory Guide 1.183, "Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors,"

July 2000 (ADAMS Accession No. ML003716792).

40.

Helker, D. P., Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "Updated Final Safety Analysis Report (UFSAR), Revision 19, Fire Hazards Analysis Report (FHAR), Revision 18, UFSAR and FHAR Reference Drawings," dated October 15, 3015 (ADAMS Accession No. ML15307A558).

41.

U.S. Nuclear Regulatory Commission, SECY-99-168, "Improving Decommissioning Regulations for Nuclear Power Plants," dated June 30, 1999 (ADAMS Accession No. ML12265A598).

42.

DiFrancesco, N.J., U.S. Nuclear Regulatory Commission, letter to Bryan C. Hanson, Exelon Generation Company, LLC, "Oyster Creek Nuclear Generating Station - Staff Assessment of Information Provided Pursuant to Title 1 O of the Code of Federal Regulations Part 50, Section 50.54(f) Seismic Hazard Reevaluations for Recommendation 2.1 of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident (CAC No. MF5257)," dated February 17, 2016 (ADAMS Accession No. ML15350A353).

43.

U.S. Nuclear Regulatory Commission, NUREG-0612, "Control of Heavy Loads at Nuclear Power Plants: Resolution of Generic Technical Activity A-36," July 1980 (ADAMS Accession No. ML070250180).

44.

U.S. Nuclear Regulatory Commission, Regulatory Guide 1.13, Revision 2, "Spent Fuel Storage Facility Design Basis," March 2007 (ADAMS Accession No. ML070310035).

45.

Lamb, J., U.S. Nuclear Regulatory Commission, electronic mail to David Helker, Exelon Generation Company, LLC, "Oyster Creek Nuclear Generating Station - Request for Additional Information Regarding License Amendment Request for Emergency Plan Exemption (CAC No. MG0153; EPID L-2017-LLE-020)," dated November 16, 2017 (ADAMS Accession No. ML17320A637).

46.

U.S. Nuclear Regulatory Commission Bulletin 2005-02, "Emergency Preparedness and

. Response Actions for Security-Based Events," dated July 18, 2005 (ADAMS Accession No. ML051740058).

47.

Nuclear Energy Institute, NEI 99-01, Revision 6, "Development of Emergency Action Levels for Non-Passive Reactors," November 2012 (ADAMS Accession No. ML12326A805).

48.

Thaggard, M., U.S. Nuclear Regulatory Commission, letter to Susan Perkins-Grew, Nuclear Energy Institute, "U.S. Nuclear Regulatory Commission Review and Endorsement of NEI 99-01, Revision 6, dated November 2012 {TAC No. D92368),"

dated March 28, 2013 (ADAMS Accession No. ML12346A463).

49.

Gallagher, M. P, Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "License Amendment Request - Proposed Changes to the Oyster Creek Emergency Plan for Permanently Defueled Emergency Plan and Emergency Action Level Scheme," dated August 29, 2017 (ADAMS Accession No. ML17241A065).

50.

U.S. Nuclear Regulatory Commission, NUREG-0696, "Functional Criteria for Emergency Response Facilities, Final Report," February 1981 (ADAMS Accession No. ML051390358).

51.

Lamb, J., U.S. Nuclear Regulatory Commission, electronic mail to David Helker, Exelon Generation Company, LLC, "Oyster Creek Nuclear Generating Station - Oyster Creek Permanently Ceases Power Operations)," dated September 17, 2018 (ADAMS Accession No. ML18263A163).

52.

Gallagher, M. P, Exelon Generation Company, LLC, letter to U.S. Nuclear Regulatory Commission, "Certification of Permanent Removal of Fuel from the Reactor Vessel for Oyster Creek Nuclear Generating Station," dated September 25, 2018 (ADAMS Accession No. ML18268A258).

Principal Contributors: J. Arce, NSIR G. Curran, NRR S. Jones, NRR E. Dickson, NRR Date: October 16, 2018

Ltr and SE ML18220A980; Exemption ML18220B027; Exemption FRN ML18220A971

  • via memo; -via email OFFICE NRR/DORL/LSPB/PM NRR/DORL/LSPB/LA NRR/DSS/SBPB/BC*'*

NSIR/DPR/RLB/BC*

NAME JLamb JBurkhardt RDennig JAnderson DATE 08/09/18 08/13/18 03/22/18 05/31/18 OFFICE NMSS/DUWP/RDB/BC** NRR/DRA/ARCB/BC*

OGC-NLO*'*

NRR/DORL/LSPB/BC NAME BWatson KHsueh JWachutka DBroaddus DATE 08/15/18 05/11/18 08/23/18 10/03/18 OFFICE NRR/DORL/DD NRR/DORL/LSPB/PM NAME KBrock JLamb DATE 10/09/18 10/16/18