05000272/LER-1981-020-03, /03L-0:on 810224,snubber on Top of RHR Pump 11 Was Found to Be Defective.Probably Caused by Intermittent Seizing of Balls in Race Due to Internal Corrosion.Snubber Replaced

From kanterella
(Redirected from ML18086A652)
Jump to navigation Jump to search
/03L-0:on 810224,snubber on Top of RHR Pump 11 Was Found to Be Defective.Probably Caused by Intermittent Seizing of Balls in Race Due to Internal Corrosion.Snubber Replaced
ML18086A652
Person / Time
Site: Salem 
Issue date: 03/25/1981
From: Steele W
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18086A651 List:
References
IEB-81-01, IEB-81-1, LER-81-020-03L, LER-81-20-3L, NUDOCS 8106090571
Download: ML18086A652 (1)


LER-1981-020, /03L-0:on 810224,snubber on Top of RHR Pump 11 Was Found to Be Defective.Probably Caused by Intermittent Seizing of Balls in Race Due to Internal Corrosion.Snubber Replaced
Event date:
Report date:
2721981020R03 - NRC Website

text

" *

  • F OhiVI 366

{7* 17)..

e LICENSEE EVENT REPORT 9'

CONTROL BLOCK: ~~-~'

  • __ 1.-l__l_j 8 (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 6

~IM rJ Isl GI sl1 101 01 01 -Io! ol 01 ol o! -1 oj o!G)[~_J_1l 1l 1l 1101 I 10 7

8 9

'LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 CON'T ITI1J 7

B

~:~~~~©I ol 51 olo I ol 21 71 210101212 1418 ll IG)I Ol3 I 2ls I Bl1 IG) f'O 61 DOCKET NUMBER 6B 69 EVENT DATE 74 75 REPORT DATE BO EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

!During normal operations at 1925 hours0.0223 days <br />0.535 hours <br />0.00318 weeks <br />7.324625e-4 months <br /> on 2/24/81, the No. 11 RHR Pump was

[£))] I declared inoperable in order to perform Engineering Test DCR #1EI1153 IAW NRC

~

jBulletin 81-01, "Surveillance of Mechanical Snubbers".

Action Statement 3.5.2 was [QJ]J I entered.at this time.

The snubber mounted on the top of the pump motor was found [9J}] 1to be defective.

Previous similar occurrences:

79-54 and 81-17.

[ill]

7 8

9

~

7 8

SYSTEM CODE Is IF I@

9 10

CAUSE

CAUSE CODE SUB CODE

~@ ~@

11 12 COMPONEfl.1T CODE I s I ujP I 01 RI Tl~

13 18 SEQUENTIAL OCCURRENCE

(,':;\\

LE R RO CV ENT YE/o.R REPORT NO.

CODE

\\'.__'.) NRC:,.~~~ I 8 I 1 I I

I I 0 12 I 0 I I/ I I 0 I 3 I 2,

22 23 24 26 2 7 28 29 COMP.

SUB CODE

~@

19 REPORT TYPE L!J 30 VALVE SUBCODE LJ@

20 l=:J 31 ACTION FUTURE EFFECT SHUTDOWN r:;::.,

ATTACHMENT NPAD-4 FOAM !:>UB.

PRIME COMP.

SUPPLIER REVISION NC.

LQJ 32 COMPOl\\E'-IT MANUFACTURER 80 TAKE!*

ACTION ON PLANT METHOD HOURS ~ SUBMITTED

@J@l_U@ W@

~ I 01 oj 01 oJ

~@

33 34 3~

36 37 40 41 L.!J@

L2:.J@

I I I l I 3 I 7 J@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

42 43 44 47 jThe apparent cause of the snubbers failure appears to be the result of internal o::IJJ 1corrosion that caused intermittent seizing of the balls in the race.

The OJ)) I defective snubber was replaced in kind with one that was tested satisfactory.

The ITl2J jAction Statement was terminated at 2015 hours0.0233 days <br />0.56 hours <br />0.00333 weeks <br />7.667075e-4 months <br /> on 2/25/81.

7 8

9 FACILITY f:30\\

STATUS

~;.POWER OTHEASTATUS ~

80 METHOD OF A

[QI] ~@

11 I 0 I 0 1@).._I __

N-"-/A ___

J DISCOVERY DISCOVERY DESCRIPTION 6 l_:j~l.._~~-I_n_s_e_r_v~i_c_e~I~n_s_p_e_c_t~i_o_n~~~~~~~~--'

7 8

9 ACTIVITY 10 CONTENT 12 13 44 RELEASED OF RELEASE AMOUNT OF ACTIVITY 0 C2:TIJ ~@) W@...... I ____

__,N/_A __

7 8

9 10 11 44 PERSONNEL EXPOSURES r:;;:;.,

45 80 LOCATION OF RELEASE @

N/A 45 BO NUMBER

(:;::;\\TYPE

DESCRIPTION

ITI2J I 0 I 0 I 010~@.___ __ ~NL-"A~-----------------------'

7 B

9 11 12 13 80 PERSONNEL INJURIES

(,;":;\\

NUMBER DESCAIPTION6 EID ol ol ol@).__~~~~~N~A=-~--~---------~-------~

7 8

9 11 12 80 LOSS OF OR DAMAGE TO FACILITY (,8\\

TYPE

DESCRIPTION

i.::_::,I E::TIJ W@

NA 7

B 9

1~0~~~~~~~~~~~-'-'~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~---'

80 PUBLICITY

~

ISSUED(,;";\\ DESCRIPTION~

I2:Ifil l.BJ~'--~~~~~~~~~N"'-"-'A~~~~~~~~~~~~~~~~-J NRC USE ONLY I I I I I I I I I I I IJ B

9 10 r::.7 I

J 0 () 09 O NAM~F PR~ARER ___

W_._J_. -----------

7 68 69 BO Steele 609-935-0998 PHONE:

c; 0

II.