05000272/LER-1981-008, Forwards LER 81-008/03L-0

From kanterella
Jump to navigation Jump to search
Forwards LER 81-008/03L-0
ML18085A906
Person / Time
Site: Salem PSEG icon.png
Issue date: 02/12/1981
From: Uderitz R
Public Service Enterprise Group
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18085A907 List:
References
NUDOCS 8102250659
Download: ML18085A906 (2)


LER-1981-008, Forwards LER 81-008/03L-0
Event date:
Report date:
2721981008R00 - NRC Website

text

~-:.:..,.*

a

.. ~

OPS~G Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 Phone 201/430-7000 Mr. Boyce H. Grier Director of USNRC February 12, 1981 Off ice of Inspection and Enforcement Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Grier:

LICENSE NO. DPR-70 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 81-08/03L Pursuant to the requirements of Salem Generating Station Unit No. 1 Technical Specifications, Section 6.9.1, we are submitting Licensee Event Report for Reportable Occurrence 81-08/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours,

/£2&14/

R. A. uderitz General Manager -

Nuclear Production CC:

Director, Office of Inspection and Enforcement (30 copies)

Director, Office of Management Information and Program Control (3 copies)

~~

~

"* U:\\HSOF St:ll\\U'E

\\ ?-7P.

Report Number:

81-08/03L Report Date:

February 12, 1981 Occurrence Date:

1/24/81 Facility:

Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancock's Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Auxiliary Annunciator Typewriter Failure CO~DITIONS PRIOR TO OCCURRENCE:

Mode 1 -

Rx Power 95% - Unit Load 1050 MW DESCRIPTION OF OCCURRENCE:

During normal operation at 0550 hours0.00637 days <br />0.153 hours <br />9.093915e-4 weeks <br />2.09275e-4 months <br /> on January 24, 1981, the carriage guide wire of the auxiliary annunciator typewriter broke.

This resulted in the loss of the Containment Sump Level Monitoring System.

Action Statement 3.4.6.1.b was entered which allows operation to continue for up to 30 days with this system inoperable.

A lamp was connected across the Containment Sump Pump Breaker and an operator was stationed at the breaker to record the operating time of the pump until repairs to the typewriter were completed.

This occurrence constituted operati9n in a degraded mode IAW Technical Specification 6.9.1.9.b.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

Equipment Failure ANALYSIS OF OCCURRENCE:

With an operator stationed at the Containment Sump Pump Breakers, all operations of the pump were recorded.

CORRECTIVE ACTION

The broken carriage guide wire was replaced by an IBM maintenance technician.

The Action Statement was terminated at 2106 hours0.0244 days <br />0.585 hours <br />0.00348 weeks <br />8.01333e-4 months <br /> on January 24, 1981.

FAILURE DATA:

IBM Fixed Typewriter -

Type CORR - Model 73-5 Prepared By w. J. Steele Manager -

Malem Generating Station SORC Meeting No.

81-07