Text
IBUTION AFTER ISSUANCE OF OPERATING LICENSE U.S. NUCI.EAR REGULATORY COMIV N
NRC DISTRIBUTION FDR PART 50 DOCKET MATERIAL DOCKET NUMBER FILE NUMBER G Lear gJ ETTER PfORIGINAI CICOP Y DESCRIPTION E3NOTORIZED UNC LASS IF I E D PROP INPUT FORM ENCLOSURE FROM:'iagara Mohawk Pwr Corp
- Syracuse, NY G KRhode DATE OF DOCUMENT 9-29-77 DATE RECEIVED 10-3-77 NUMBER OF COPIES RECEIVED lp addi info concerning spent fuel pool modificatio as requested in NRC ltr dtd 9-1-77..............
9p PLANT NAME:
Nine Mile Pt glil~r.~
le-3-77
+f SAFETY BRANCH CHIEF:
7 FOR ACTION/INFORMATION G FILE NRC PDR I a E (2)
OELD HANAUER CHECK STELLO EISENHUT SHAO BAER BUTLER GRIMES J.
COLLINS INTERNALD RI BUTION LPDR:
TIC NSIC 16 CYS ACRS SENT CATE 0 EXTERNALDISTRIBUTION CONTROL NUMBER
'}r v~jy I'j
(
l t.'
I II/ P gpss NIAGARAMOHAWKPOWER CORPORATION
>>Ill&~',
NIAGARA l
'OHAWK 300 ERIE BOULEVARD, WEST SYRACUSE. N. Y. I3202 September 29, 1977 Director of Nuclear. Reactor Regulation Attn:
Mr. George Lear, Chief Operating Reactors Branch g3 U.
S. Nuclear Regulatory Commission Washington, D.
C.
20555 l
f / f c7
~Cfog 64~f g Cr Re:
Nine Mile Point Unit 1 Docket No. 50-220 DPR-63
Dear Mr. Lear:
Your letter of September 1,
1977 requested additional information regarding the spent fuel pool modification for Nine Mile Point Unit,l.
The enclosed information responds to, your request.
Very truly yours, NIAGARA MOHAWK POWER CORPORATION erald Rhode Vice President-ngineering
/szd Enclosure
I' A,I
Respons es to September 1,
1977 Nuclear Re ulator Commission uest;ions Nine Nile Point Unit 1 Docl<et No. 50-220 DPR-63 QUESTION 1:
.Provide the average burn up expected for the spent fuel in the spent fuel pool (SFP).
RESPONSE
The average burn up of spent fuel in the spent fuel pool from the beginning of reactor life to the date at which the pool is completely filled (1984 fuel assemblies) is projected to be approximately 23,200 MK/NTU.
The projected average burn up assumes no spent fuel is shipped off site.
QUESTION 2:
Discuss any expected change in the radiological liquid effluents from the Liquid Radioactive Waste Disposal System (LRWDS) because of the proposed mod'ification.
Discuss the impact of the filter precoat being transferred from the Spent Fuel Storage Pool Filtering System to the LRWDS.
RESPONSE.
While there may be a slight increase in the volume of filter sludge transferred
-to the LRWDS due to the expected slight increase in filter change frequency, there should be no significant increase in the volume or concentration of liquid radio-active waste effluents.
At the present time, the spent fuel pool filter sludge is transferred to the LRWDS where it is filtered and concentrated.
The filter cake and concentrator liquid are disposed of off site as solid radioactive waste.
The waste disposal system is presently operating at approximately 60% of capacity.
The modification is expected to increase the LRWDS usage by 1 percent.
Discuss the disposition of the material to be removed from the spent fuel pool (e.g.,
spent fuel
- racks, seismic restraints) during the proposed modification. If the material to be removed will be disposed of as solid waste, provide the volume of the package waste.
RHSPONSE:
The existing spent fuel racks plus hardware will be removed from the spent fuel pool and disposed of in two phases.
Phase 1 will clear the north half of the pool. It is anticipated that fuel and channel racks removed during Phase 1 will be disposed of as low level, shallow burial solid radwaste and will consist'of four shipments 9 feet by 8 feet by 15 feet in volume resulting in a total volume of 4,320 cubic feet, It is anticipated that the Phase 2 solid radwaste will be treated as Phase 1.
The total volume of Phase 2 radwaste will be approximately equal to that of Phase -l.
Provide the volume of solid waste to be generated by the replacement of the filter precoat in the Spent Fuel Pool Filtering System.
Provide the current frequency of operation and the normal flow rate through the filter.
Provide the current frequency of replacing the filter precoat.
Discuss and quantify any expected changes in the above due to the proposed modification.
RESPONSE
Presently the Spent Fuel Pool Filtration.System is operated continuously at a flow rate of approximately 600 gallons per minute.
The filter precoat is changed approximately once every three months yielding an estimated 5 cubic feet of radioactive solids after waste treatment.
The maximum expected filter change frequency will be once per two months to maintain the spent fuel pool radionuclide concentrations at present levels.
This increase in filter change frequency would increase the spent fuel pool contribution to solid xadioactive waste by approximately 2.5 cubic feet per 3 months or approximately 1% of our total quarterly radioactive waste generation f om filter sludge disposal in all systems.
QUESTION 5:
Explain why no equipment modifications for the Spent Fuel Storage Pool Filtering System (SFSPFS) were proposed.
Consider that the proposed SFP modification may result in a factor of approximately eight times more fuel movements during the modification than during a normal refueling which may increase the level of crud in the pool above that expe ted during a normal refueling.
Justify why SFSPFS is adequate to maintain low fuel pool concentration of radioactivity including crud so that there are reasonably low exposure levels in and around the fuel pool area during and after the modification.
RESPONSE
The expansion of the spent fuel capacity at Unit 1 will be done in phases.
During the first phase of installation approximately 1000 storage locations will be installed in the north half of the pool.
The north half of the pool contains less than 200 spent fuel bundles, there-fore, the first phase should require moving only these fuel assemblies.
During a normal refueling, approximately 150 to 200 fuel bundles are transferred from the core to the spent fuel pool.
The fuel moves performed during a normal refueling would result in a higher concentration of radioactivity than the moves required for the first phase of installation due to length of time since shutdown associated with the bundles.
The fuel bundles discharged during a refueling would be the most recently. irradiated exhibiting the highest radioactivity levels.
The fuel bundles to be moved during the first phase of installation will have been in storage for a period of time, decreasing the crud radioactivity levels.
Therefore, fuel moves associated with the first phase of installation are not expected to result in any substantial increase in the level of crud in the pool above that expected during a normal refueling.
The
. econd phase of installation is not expected to take place until approximately 1980-81.
Prior to this time, fuel assemblies in the south end of the pooi will on a gradual basis be transferred to the north end of the pool to allow adequate room for the second phase of installation.
The movement of these fuel assemblies during this time period is not expected to result in any increase in the level of crud in the pool above that expected during a normal refueling.
RESPONSE
5:
Continued Host of the dose rate contribution above the pool is due to activity in the water from recently discharged spent fuel bundles.
Since the proposed expansion would not increase the number of recently discharged
- bundles, the change in dose rates above the pool is expected to be insignificant.
Presently, the dose rate above the pool is controlled to between 5 and 10 MR/HR, by controlling the frequency of change of the spent fuel pool filter.
As shown
- above, the expansion is not expected to result in any substantial increase in the level of crud in the pool above that normally expected during a refueling outage.
Since the policy of changing the spent fuel filters as often as necessary to maintain the radiation dose rate around the spent fuel storage pool to levels between 5 and 10 MR/HR will continue, no increased occupational exposure is anticipated due to personnel working in the pool vicinity and no equipment modifications for the Spent Fuel Storage Pool Filtering System are required.
QUESTION 6:
Provide a discussion of the increases and the doses to personnel from radionuclide concentrations in the SPP due to the expansion of the capacity of the
- SFP, including the following:
a)
Identify t:he principle radionuclides and their respective concentrations in the spent fuel pool water found by gamma isotopic analysis during all operations.
Identify the sample with respect to a specific operation (i.e.,
refueling, fuel handling, etc,).
b)
Provide an estimate of the man-rem exposure that will be received during removal of the old racks and installation of the new ones.
c)
Provide an estimate of the dose rates above
'he spent fuel pool from the concentrations of the radionuclides identified in (a),
and the concomitant occupational
- exposure, in annual man-rem, due to all operations associated with fuel handling in the spent fuel pool area.
Describe the impact of the proposed modifications on these estimates.
Include in your analysis the expected exposure from more frequent changing of the filter precoat.
RESPONSE
r The attached isotopic analysis and gross activity data indicate activity levels expected during normal operating refueling operations as well as those found during fuel channel cutting, crushing, and packaging.
The fuel channel work is performed during normal station operation.
A preliminary conservative estimate of exposure during removal of the old racks and installation of new ones is approximately 16 man-rems.
As working procedures are finalized, a more accurate exposure may be obtain-able.
The 16 man-rems is based on the following assumptions".
8 weeks of installation (18 personnel around pool)
Use of a Diver (4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> per day for 10 days) 5 MR/hr around pool 50 MR/hr in the pool This estimate is conservative when compared to rack replacements performed at Oyster Creek and Ginna.
RESPONSE
6:
Continued Vhole body dose rates at the spent fuel pool rail generally vary between 5 and 10 millirem.
Effective dose rates for work carried on in the vicinity of the pool amount to less than 5 millirem/hr because rates in many areas of the floor are only 1 to 2
millirem/hr.
An estimate of annual man-rems associated with fuel pool area work can be made by using the portion of refueling exposure received by operators, reactor
- physists, and instrument technicians (maintenance exposure should not be included since this exposure category includes drywe11 and vessel disas'sembly, decontamination, and reassembly).
Contractor exposures should also be included.
NAN-RENS 1975 (including Refuelin Outa e) 1976 (Ho Refuelin Outa e)
Operators Reactor Physists Instrument 6 Control Contractors
.9
- 0. 046
- 0. 588
- 5. 134 0.05 0.000 0.010 2.652 The proposed modifications will not affect the portion of the exposure received during refueling.
Since shipment of the spent fuel will be postponed, the modification ultimately will result in lower exposure for that operation due to increased decay time prior to shipment.
Since dose rate at the fuel pool rail only varies slightly with fuel pool activity, and since this activity is easily controlled, the only impact on man-rems received in the fuel pool area will be that received during the modification.
The average man-rems received during waste processing and. shipment was 102 in 1975 and 104 in 1976.
Xt is expected that filter sludge volume may increase by approximately 1%.
This could increase exposures by approximately one man-rem/year if it were conservatively assumed all waste processing exposures were attributable to filter sludge.
Spent Fuel Pool Data Operation D
'~1977 Normal Operation CPM/ml 200-1000 MR/HR Anal sis pci/ml Cs-134 Cs-137 Co-60 (x 10
)
~(x 10
~x10 Refueling
~2400 Fuel Channel Crusbing
& Cutting 200-2700 5-10 14