MONTHYEARML24025A1592024-01-25025 January 2024 NRR E-mail Capture - Shearon Harris Nuclear Power Plant, Unit 1 - Request for Additional Information - Rvi AMP and Inspection Plan (L-2023-LLL-0016) ML23177A1992023-06-26026 June 2023 NRR E-mail Capture - Acceptance Review - Shearon Harris Nuclear Power Plant, Unit 1 - RA-23-0005 - LAR to Align Certain TSs with ISTS (L-2023-LLA-0078) ML23172A0132023-06-20020 June 2023 Duke Fleet - Correction to June 2, 2023, Request for Additional Information Proposed License Amendment Request to Revise Restrictive Surveillance Requirement Frequencies ML23153A1892023-06-0202 June 2023 Duke Fleet - Request for Additional Information Proposed License Amendment Request to Revise Restrictive Surveillance Requirement Frequencies ML23151A3482023-05-30030 May 2023 Duke Fleet - Request for Additional Information Proposed Alternative for Pressurizer Welds in Accordance with 10 CFR 50.55a(z)(1) ML23142A2732023-05-22022 May 2023 Duke Fleet - Request for Additional Information Proposed Alternative for Steam Generator Welds in Accordance with 10 CFR 50.55a(z)(1) ML23124A1212023-05-0404 May 2023 Acceptance of Requested Licensing Action Duke Fleet Proposed Alternative for Pressurizer Welds in Accordance with 10 CFR 50.55a(z)(1) ML23082A0432023-03-23023 March 2023 002 Radiation Safety Baseline Inspection Information Request Final ML23073A2282023-03-13013 March 2023 Duke Fleet- Adoption of TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements - Acceptance Review ML23065A0942023-03-0606 March 2023 NRR E-mail Capture - Acceptance Review - Shearon Harris Nuclear Power Plant, Unit 1 - RA-22-0081 - LAR to Address Administrative Changes to the Operating License and Technical Specifications (L-2023-LLA-0020) ML23058A0562023-02-27027 February 2023 Acceptance of Amendment to Revise Surveillance Frequencies for RCS Pressure Isolation Valve Operational Leakage Testing and Reactor Trip System Instrumentation ML23048A1512023-02-16016 February 2023 Acceptance Review - Proposed Alternative for Steam Generator Welds (L-2023-LLR-0003) ML22237A1632022-08-25025 August 2022 004 Radiation Safety Baseline Inspection Information Request ML22115A1412022-04-25025 April 2022 NRR E-mail Capture - Duke Common EOF Relocation - Request for Addition Information ML22108A0182022-04-15015 April 2022 NRR E-mail Capture - Accepted for Review - Duke Energy Relief Request for Harris Nuclear Plant Inservice Testing Program Plan - Fourth Ten-Year Interval to Extend Type C Test to 75 Months ML22083A0702022-03-24024 March 2022 NRR E-mail Capture - Catawba Nuclear Station, Units 1 and 2, Shearon Harris Nuclear Power Plant, Unit 1, and McGuire Nuclear Station, Units 1 and 2 - Acceptance Review for TSTF-569 LAR ML22083A0282022-03-23023 March 2022 Email Snsb Safety Evaluation for Harris LAR to Revise Reactor Protection System TS ML22038A1572022-02-0707 February 2022 NRR E-mail Capture - Duke Energy Fleet - Acceptance of License Amendment Request Regarding Adoption of TSTF-541, Revision 2 ML22018A0272022-01-18018 January 2022 2022 All RFI Responses - Exercise and Program Inspections - Revl ML21361A0122021-12-23023 December 2021 NRR E-mail Capture - Accepted for Review - Duke Energy Fleet License Amendment Request to Relocate Emergency Operations Facility ML21354A8612021-12-15015 December 2021 NRR E-mail Capture - Request for Additional Information - Duke Fleet Request RA-19-0352 - Alternative for RPV Closure Stud Exams (L-2020-LLR-0156) ML21321A3782021-11-16016 November 2021 NRR E-mail Capture - Energy Harbor Fleet, Beaver Valley Units 1 and 2 and DAVIS-BESSEL Unit 1 - Acceptance of License Amendment Request Adoption of TSTF-554 EPID-L-2021-LLA-0193 ML21288A0802021-10-15015 October 2021 NRR E-mail Capture - Acceptance Review - Shearon Harris Nuclear Power Plant, Unit 1 - RA-21-0213 - Remove Limitations to Perform Certain SRs During Shutdown (L-2021-LLA-0167) ML21295A0372021-10-0505 October 2021 NRR E-mail Capture - Accepted for Review - Duke Energy Fleet License Amendment Request to Adopt TSTF-577 Revised Frequencies for Steam Generator Tube Inspections ML21252A0112021-08-30030 August 2021 NRR E-mail Capture - Acceptance Review - Shearon Harris Nuclear Power Plant, Unit 1- RA-21-0191 - Revised TS Related to Reactor Trip System Instrumentation (L-2021-LLA-0149) ML21189A0282021-07-0101 July 2021 NRR E-mail Capture - Acceptance Review - Shearon Harris Nuclear Power Plant, Unit 1 - RA-21-0112 - Revise TS to Reflect Development of TRM (L-2021-LLA-0108) ML21172A2432021-06-21021 June 2021 NRR E-mail Capture - Request for Additional Information - Harris RA-20-0252 - LAR to Remove Extraneous Requirements from OL and TS (L-2021-LLA-0027) ML21106A0112021-04-15015 April 2021 NRR E-mail Capture - Acceptance Review - Shearon Harris Nuclear Power Plant, Unit 1 - RA-21-0052 - Revise Containment Spray Nozzle Surveillance Frequency (L-2021-LLA-0058) ML21084A2492021-03-24024 March 2021 Notification of Inspection and Request for Information ML21084A2512021-03-22022 March 2021 NRR E-mail Capture - Acceptance Review - Shearon Harris Nuclear Power Plant, Unit 1 - RA-20-0252 - LAR to Remove Extraneous Content and Requirements from the OL and TS (L-2021-LLA-0027) ML21039A6382021-02-0808 February 2021 NRR E-mail Capture - Acceptance Review - Shearon Harris Nuclear Power Plant, Unit 1-RA-20-0311 - 10 CFR 50.69 Categorization Process to Reflect an Alternative Seismic Approach (L-2021-LLA-0003) ML21036A1142021-02-0505 February 2021 NRR E-mail Capture - Request for Additional Information - Harris - Relief Request RA-20-0312 - SW Pinhole Leak (L-2020-LLR-0143) ML21049A2632021-02-0404 February 2021 NRR E-mail Capture - Request for Additional Information - Duke Energy Fleet License Amendment Request to Revise Emergency Plan ML21033A8452021-02-0202 February 2021 NRR E-mail Capture - State Notification of Amendments to Shearon Harris Nuclear Power Plant, Unit 1 - Revision Minimum RCS Flow Rate and Update COLR References ML21033B1062021-02-0202 February 2021 NRR E-mail Capture - (External_Sender) (External) State Notification of Amendments to Shearon Harris Nuclear Power Plant, Unit 1 - Revision Minimum RCS Flow Rate and Update COLR References ML21032A0492021-02-0101 February 2021 NRR E-mail Capture - Request for Additional Information - Duke Fleet RA-20-0263 - Use of Later ASME B&Pv, XI for Repair - Replacement (L-2020-LLR-0124) ML21025A2922021-01-25025 January 2021 NRR E-mail Capture - (External_Sender) State Notification of Amendment to Shearon Harris Nuclear Power Plant, Unit 1 - Revise TS 3/4.4.9, Pressure/Temperature Limits - Reactor Coolant System ML21007A3722021-01-0707 January 2021 NRR E-mail Capture - Acceptance Review - Duke Fleet - RA-19-0352 - Proposed Alternative for Reactor Vessel Close Stud Examinations (L-2020-LLR-0156) ML21006A4302021-01-0606 January 2021 Acceptance Review - Duke Fleet RA-20-0207 Request to Revise the Technical Specification for Engineered Safety Feature Actuation System (ESFAS) Instrumentation ML21006A4042021-01-0606 January 2021 NRR E-mail Capture - State Notification of Amendment to Shearon Harris Nuclear Power Plant, Unit 1 - Revise TS 3/4.4.9, Pressure/Temperature Limits - Reactor Coolant System ML20345A3052020-12-10010 December 2020 NRR E-mail Capture - (External_Sender) (External) State Notification of Amendments to Shearon Harris Nuclear Power Plant, Unit 1 - Revise TS 3.3.3.6 and TS 3.9.2 ML20344A4192020-12-0909 December 2020 NRR E-mail Capture - State Notification of Amendments to Shearon Harris Nuclear Power Plant, Unit 1 - Revise TS 3.3.3.6 and TS 3.9.2 ML20328A0802020-11-23023 November 2020 NRR E-mail Capture - Acceptance Review - Shearon Harris Nuclear Power Plant, Unit 1 - RA-20-0312-Relief Request, Service Water Pinhole Leak in a Socket Weld, Inservice Inspection (L-2020-LLR-0143) ML20323A4072020-11-18018 November 2020 NRR E-mail Capture - Request for Additional Information - Brunswick License Exemption Request from 10CFR73 Annual Force on Force Exercise Requirements (EPIC L-2020-LLE-0180) ML20297A3102020-10-13013 October 2020 NRR E-mail Capture - Acceptance Review - Duke Fleet - RA-20-0191 - Request to Use a Provision of a Later Edition of the ASME B&PV Code, Section XI - IWA-5120, IWA-5213, IWA-5241, IWA-5242, and IWA-5250 (L-2020-LLR-0126) ML20297A3072020-10-13013 October 2020 NRR E-mail Capture - Request for Additional Information - Shearon Harris Nuclear Power Plant, Unit 1 - RCS Flowrate Reduction/Lbloca LAR ML20297A3082020-10-0707 October 2020 NRR E-mail Capture - Acceptance Review - Duke Fleet - RA-20-0263 - Request to Use a Provision of a Later Edition of the ASME B&PV Code, Section XI for Repair/Replacement (L-2020-LLR-0124) ML20297A3092020-10-0606 October 2020 NRR E-mail Capture - Acceptance Review - Duke Fleet - RA-20-0262 - Request to Use a Provision of a Later Edition of the ASME B&PV Code, Section XI - IWA-4540(b) (L-2020-LLR-0125) ML20274A0462020-09-29029 September 2020 Request for Additional Information Regarding License Amendment Request to Adopt TSTF-505, Revision 2 ML20247J3822020-09-0303 September 2020 Request for Additional Information - Shearon Harris Nuclear Power Plant, Unit 1 - Revise TS Related to Accident Monitoring and RFO Instrumentation 2024-01-25
[Table view] |
Text
NRR-PMDAPEm Resource From: Barillas, Martha Sent: Friday, October 21, 2016 3:43 PM To: Caves, John; McDaniel, Sarah A; Tanya.Hamilton@duke-energy.com Cc: Dion, Jeanne; Hon, Andrew; Alley, David; Tsao, John
Subject:
Harris RR I3R16 RVCH Nozzle Repair Technique, ISI Program, Third Ten-Year Interval DRAFT RAI (MF8487)
Attachments: Harris RR I3R16 draft RAI MF8487.docx Mr. Caves, By letter dated October 19, 2016 (Agencywide Documents Access and Management System (ADAMS)
Accession No. ML16294A218) as supplemented by letter dated October 21, 2016 (ADAMS Accession No. ML16295A159), Duke Energy Progress, LLC (the licensee) submitted relief request (RR) I3R-16 for Shearon Harris Nuclear Power Plant, Unit 1. The RR I3R-16 requests to use an alternate method in accordance with the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, to do the repair of flaw indications detected during the Inservice Inspection (ISI) program ultrasonic examination of the reactor vessel closure head penetration nozzles 30, 40, and 51. The RR I3R-16 is for the third 10-year Inservice Inspection (ISI) interval, which is scheduled to end on May 1, 2017. To complete its review, the NRC staff has the following request for additional information attached in DRAFT form.
If a clarification call is needed to discuss the attached draft RAI, it is requested you respond by October 24, 2016. Otherwise, we request the RAI response by October 26, 2016, in order to support your request. If you do not believe you can meet this date, please provide an acceptable alternate date and justification for extending the response date.
If you need to contact me, I may be reached at (301) 415-2760 or via e-mail Martha.Barillas@nrc.gov.
Respectfully, Martha Barillas Project Manager Shearon Harris Nuclear Power Plant, Unit 1 NRR/DORL/Licensing Branch II-2 US Nuclear Regulatory Commission 301-415-2760 1
Hearing Identifier: NRR_PMDA Email Number: 3123 Mail Envelope Properties (Martha.Barillas@nrc.gov20161021154300)
Subject:
Harris RR I3R16 RVCH Nozzle Repair Technique, ISI Program, Third Ten-Year Interval DRAFT RAI (MF8487)
Sent Date: 10/21/2016 3:43:12 PM Received Date: 10/21/2016 3:43:00 PM From: Barillas, Martha Created By: Martha.Barillas@nrc.gov Recipients:
"Dion, Jeanne" <Jeanne.Dion@nrc.gov>
Tracking Status: None "Hon, Andrew" <Andrew.Hon@nrc.gov>
Tracking Status: None "Alley, David" <David.Alley@nrc.gov>
Tracking Status: None "Tsao, John" <John.Tsao@nrc.gov>
Tracking Status: None "Caves, John" <John.Caves@duke-energy.com>
Tracking Status: None "McDaniel, Sarah A" <Sarah.McDaniel@duke-energy.com>
Tracking Status: None "Tanya.Hamilton@duke-energy.com" <Tanya.Hamilton@duke-energy.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 1664 10/21/2016 3:43:00 PM Harris RR I3R16 draft RAI MF8487.docx 25556 Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received:
DRAFT REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST I3R-16 ALTERNATE REPAIR OF REACTOR VESSEL CLOSURE HEAD NOZZLES 30, 40, and 51 SHEARON HARRIS NUCLEAR POWER PLANT UNIT NO.1 DUKE ENERGY PROGRESS, LLC DOCKET NO. 50-400 By letter dated October 19, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16294A218) as supplemented by letter dated October 21, 2016 (ADAMS Accession No. ML16295A159), Duke Energy Progress, LLC (the licensee) submitted relief request (RR) I3R-16 for Shearon Harris Nuclear Power Plant, Unit 1. The RR I3R-16 requests to use an alternate method in accordance with the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, to do the repair of flaw indications detected during the Inservice Inspection (ISI) program ultrasonic examination of the reactor vessel closure head penetration nozzles. The RR I3R-16 is for the third 10-year Inservice Inspection (ISI) interval, which is scheduled to end on May 1, 2017. To complete its review, the NRC staff requests the following additional information.
- 1. Section 1 of the letter referenced above identified the affected components as Reactor Vessel Closure Head (RVCH) Penetration Nozzles without identifying specific nozzles.
Section 4 of the letter referenced above identified nozzle numbers 30, 40 and 51 that need to be repaired. Clarify whether the relief request is applicable to only RVCH nozzle numbers 30, 40 and 51 or to all RVCH nozzles that have not been repaired.
- 2. In a letter dated April 29, 2015, the licensee notified the NRC that its evaluation of the impact of a residual flaw in the J-groove weld contained an error as documented in Calculation 32-9176350-001, Shearon Harris Unit 1 CRDM/CET Nozzle As-Left J-groove Weld Analysis. The licensee submitted calculation 32-9176350-001 to support relief request I3R-13 (ADAMS Accession No. ML13330A996). The licensee referenced calculation 32-9176350-001 in the original RR I3R-15 submittal dated April 2, 2015.
Subsequently, the licensee corrected the original calculation and submitted the revised Calculation 32-9176350-002 as documented in enclosure 3 of the submittal dated April 29, 2015 (ADAMS Accession No. 15120A406). Confirm that the error in Calculation 32-9176350-001 in Relief Request I3R-13 has been removed and is not contained in Calculation 32-9176350-003 that is a part of the current Relief Request I3R-16.
- 3. Discuss how the roll expansion joint will be applied and measures will be taken in the repair of the three RVCH nozzles in the Fall 2016 refueling outage to minimize stresses in the region above the roll expansion so as to prevent primary stress corrosion cracking in that region.
- 4. During the current Fall 2016 refueling outage, the licensee discovered an indication in repaired RVCH nozzle number 23 as discussed in Event Notification (EN) 52297.
Discuss the measures and/or procedures that the proposed repair in Relief Request I3R-16 will implement or were implemented to minimize the occurrence of the indication that
was discovered in nozzle number 23. If no measures have been implemented, provide justification.
- 5. In Relief Request I3R-15, the licensee stated that the nozzle numbers 14, 18 and 23 that were repaired in 2015 have a design life of 2.2 effective full power years. Section 5, page 11, of current Relief Request I3R-16 discussed a limiting life of 5 years for the subject nozzle numbers 30, 40 and 51. Section 6 of I3R-16 states that The minimum life of 5 years is predicted based on the as-left J-groove flaw evaluation. The 2.2 EFPY is based on a separate PWSCC evaluation in the exposed original Alloy 600 nozzle. The overall acceptable life of the repair design is based on the most limiting life predicted amongst the weld anomaly analysis, the as-left J-groove analysis and the PWSCC evaluation of the original Alloy 600 nozzle, which is 2.2 EFPY... Clarify whether the design life for the subject nozzle numbers 30, 40 and 51 is 2.2 EFPY or 5 years.