Appendix H38 -

RES RAD 7.0 Output for Area 3.1 Pu

L Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit= 180 days 07/22/2016 11:17 Page summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...

2 Site-Specific Parameter Surmnary..........................

5 Summary of Pathway Selections............................

9 Contaminated Zone and Total Dose Summary.................

10 Total Dose Components Time O.OOOE+OO Time l.OOOE+OO Time 3.000E+OO Time l.OOOE+Ol Time 3.000E+Ol Time l.OOOE+02 Time Time 3.000E+02 l.OOOE+03 Dose/Source Ratios Summed Over All Pathways..............

Single Radionuclide Soil Guidelines......................

Dose Per Nuclide Summed Over All Pathways................

Soil Concentration P~r Nuclide...........................

11 12 13 14 15 16 17 18 19 20 22 24 Page 1of25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit~ 180 days 07/22/2016 11:17 Page 2

Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 11 Current Base Parameter Menu Parameter Value#

Case*

Name A-1 DCF's for external ground radiation, (mrem/yr)/(pCi/g)

A-1 Ac-227 (Source: FGR 12) 4.951E-04 4.951E-04 DCFl (

1)

A-1 At-219 (Source: no data)

O.OOOE+OO

~2.000E+OO DCFl (. 2)

A-1 Ba-137m (Source: FGR 12) 3.606E+OO 3.606E+OO DCFl (.

3)

A-1 Bi-211 (Source: FGR 12) 2.559E-01 2.559E-01 DCFl (

4)

A-1 Bi-215 (Source: no data) 0.000E+OO

-2.000E+OO DCFl (

5)

A-1 Cs-137 (Source: FGR 12) 7.510E-04 7.510E-04 DCFl (

6)

A-1 Fr-223 (Source: FGR 12) 1.980E-01 l.980E-01 DCFl (

7)

A-1 Pa-231 (Source: FGR 12)

1. 906E-01
  • 1.906E-01 DCFl (
8)

A-1 Pb-211 (Source: FGR 12) 3.064E-01 3.064E-01 DCFl (

9)

A-1 Po-211 (Source: FGR 12)

4. 764E-02 4.764E-02 DCFl ( 10)

A-1 Po-215 (Source: FGR 12)

1. 016E-03
1. 016E-03 DCFl ( 11)

A-1 Pu-239 (Source: FGR 12) 2.952E-04 2.952E-04 DCFl ( 12)

A-1 Ra-223 (Source: FGR 12) 6.034E-01 6.034E-01 DCFl ( 13)

A-1 Rn-219 (Source: FGR 12) 3.083E-01 3.083E-01 DCFl ( 14)

A-1 Sr-90 (Source: FGR 12) 7.043E-04 7,043E-04 DCFl ( 15)

A-1 Th-227

(*Source: FGR 12) 5.212E-01 5.212E-01 DCFl ( 16)

A-1 Th-231 (Source: FGR 12) 3.643E-02 3.643E-02 DCFl ( 17)

A-1 Tl-207 (Source: FGR 12i

1. 980E-02 l.980E-02 DCFl ( 18)

A-1 U-235 (Source: FGR 12)

7. 211E-01
7. 211E-01 DCFl ( 19)

A-1 U-235m (Source: no data)

O.OOOE+OO

-1.000E+OO DCFl ( 20)

A-1 Y-90 (Source: FGR 12) 2'. 391E-02 2.391E-02 OCFl ( 21)

B-1 Dose conversion factors for inhalation, mrem/pCi.:

B-1 Ac-227+0 6.724E+OO 6.700E+OO OCF2 (

1)

B-1 Ac-227+01 6.724E+OO 6.700E+OO OCF2 ( '2)

B.-1 Ac-227+02 6.708E+OO 6.700E+00 OCF2 (

3)

B-1 Ac-227+03 6.708E+OO

6. 70.0E+OO OCF2 (
4)

B-1 Ac-227+04 6.700E+OO 6.700E+OO OCF2 (

5)

B-1 Ac-227+D5 6.700E+OO 6.700E+OO DCF2(

6)

B-1 Cs-137+D 3.190E-05 3.190E-05 OCF2 (

7)

B-1 Pa-231.

l.280E+OO 1.280E+OO DCF2 (

8)

B-1 Pu-239

4. 290E-01
4. 290E-01 DCF2 ( 14)

B-1 Pu-239+0 4.290E-01 4.290E-01 OCF2 ( 20)

B-1 Sr-90+0 l.308E-03 l.300E-03 OCF2 ( 26)

B-1 U-235+0 l.230E-01

1. 230E-01 OCF2 ( 27)

D-1 Dose conversion factors for ingestion, mrem/pCi:

D-1 Ac-227+D

1. 4 80E-02
1. 410E-02 OCF3(
1)

D-1 Ac-227+Dl

1. 4 80E-02
1. 410E-02 OCF3 (
2)

D-1 Ac-227+02

1. 4 77E-02
1. 410E-02 OCF3(
3) 0-1 Ac-227+03
1. 4 77E-02
1. 410E-02 OCF3(
4) 0-1 Ac-227+04
1. 4 llE-,-02
1. 410E-02 DCF3 (
5) 0-1 Ac-227+D5
1. 4 llE-02
1. 410E-02 OCF3 (
6) 0-1 Cs-137+D 5.000E-05 5.000E-05 OCF3 (
7)

D-1 Pa-231 l.060E-02

1. 060E-02 OCF3 (
8)

D-1 Pu-239 3.540E-03 3.540E-03 DCF3 ( 14) 0-1 Pu-239+D 3.540E-03 3.540E-03 DCF3 ( 20) 0-1 Sr-90+0

1. 528E-04 1.420E-04 DCF3 ( 26) 0-1 U-235+0 2.673E-04 2.660E-04 OCF3 ( 27)

Page 2 of 25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0

~Limit= 180 days 07/22/2016 11:17 Page 3

Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR 11 Current Base Parameter Menu Parameter Value#

Case*

Name D-34

-Food transfer factors:

D-34 Ac-227+0

' plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(

1, 1) 0-34 Ac-227+0

' beef/livestock-intake ratio, (pCi/kgl I (pCi/d)

2. OOOE-05 2.000E-05 RTF(

1, 2')

0-34 Ac-227+0 milk/livestock-intake ratio, (pCi/L)/(pCi/d)

2. OOOE-05 2.000E-05 RTF(

1,3) 0-34 0-34 Ac-227+01 ' plant/soil concentration ratio, dimensionless 2.500E-03 2.500E RTF(

2, 1)

D-34 Ac-.227+01 ' beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-05 2.000E-05

  • RTF(

2,2) 0-34 Ac-227+01 ' milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-05 2.000E-05 RTF(

2,3) 0-34 0-34 Ac-227+02 ' plant/soil concentration ratio, dirnensiorlless 2.500E-03 2.500E-03 RTF(

3,1) 0-34 Ac-227+02 ' beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-05 2.000E-05 RTF(

3,2) 0-34 Ac-227+02 ' milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-05 2.000E-05 RTF(

3,3) 0-34 0-34 Ac-227+03 ' plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(

4,1) 0-34 Ac-227+03 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-05 2.000E-05 RTF(

4,2) 0-34 Ac-227+03 ' milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-05 2.000E-05 RTF(

4,3) 0-34 D-34 Ac-227+04 ' plant/soil concentration ratio, dimensionless

2. 500E-03.

2.500E-03 RTF(

5, 1) 0-34 Ac-227+04 ' beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-05 2.000E-05 RTF(

5,2)

D-34 Ac-227+04 milk/li vestoc_k-intake rat~o, "(pCi/L) I (pCi/d) 2.000E-05

'2.000E-05 RTF(

5,3) 0-34 D-34 Ac-227+05 ' plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF(

6, 1) 0-34 Ac-227+05 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-05 2.000E-05 RTF(

6, 2) 0-34 Ac-227+05 ' milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-05 2.000E-05

6, 3) 0-34 0-34 Cs-137+0 plant/soil concentration ratio, dimensionless

4. OOOE-02 4.000E-02 RTF(

7' 1) 0-34 Cs-137+0

' beef/livestocktintake ratio, (pCi/kg)/(pCi/d) 3.000E-02 3.000E-02 RTF(

7' 2) 0-34 Cs-137+0

' milk/livestock-intake ratio, (pCi/L)/(pCi/d) 8.000E-03 8.000E-03 RTF(

7' 3) 0-34 0-34 Pa-231

' plant/soil concentration ratio, dimensionless l.OOOE-02 1.000E-02 RTF(

8' 1) 0-34 Pa-231

' beef/livestock-intake ratio, (pCi/kg) I (pCi/d) 5.000E-03

5. OOOE-03 RTF(

8,2) 0-34 Pa-231

' milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.000E-06 5.000E-06 RTF(

8,3) 0-34 0-34 Pu-239 plant/soil concentration ratio, dimensionless 1.000E-03 l.OOOE-03 RTF( 14,1) 0-34 Pu-239 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) l.OOOE-04 l.OOOE-04 RTF( 14,2) 0-34 Pu-239 milk/livestock-intake ratio, (pCi/L)/(pCi/d)

1. OOOE-06 1.000E-06 RTF( 14,3) 0-34 0-34
  • Pu-239+0 plant/soil concentration ratio, dimensionless
1. OOOE-03 l.OOOE-03 RTF( 20,1) 0-34 Pu-239+0

' beef/livestock-intake ratio, (pCi/kg) I (pCi/d) 1.000E-04 1.000E-04 RTF( 20, 2) 0-34 Pu-239t0 ' milk/livestock-intake ratio, (pCi/L)/(pCi/d)

1. OOOE-06
1. OOOE-06 RTF( 20,3) 0-34 D-34 Sr-90+0

' plant/soil concentration ratio, dimensionless.

3.000E-01 3.000E-01 RTF( 26,1) 0-34 Sr-90+0

' beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-03 8.000E-03 RTF( 26;2) 0-34 Sr-90+0

' milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-03 2.000E-03 RTF( 26,3)

D-34

  • 0-34 U-235+0

' plant/soil concentration ratio, dimensionless 2.500E-03 2.500E-03 RTF( 27,1) 0-34 U-235+0 beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.400E-04 3.400E-04 RTF( 27,2) 0-34 U-235+0

' milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-04 6.000E-04 RTF( 27,3) 0-34 Page 3 o~25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T'> Limit~ 180 days 07/22/2016 11:17 Page Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)

Dose Library: FGR *11 Current Base Parameter Menu Parameter Value#

Case*

Name D-5 Bioaccumulation factors, fresh water, L/kg:

D-5 Ac-227+D fish l.500E+Ol 1.500E+Ol BIOFAC (

1, 1)

D-5 Ac-227+D

' crustacea and mollusks 1.000E+03 l.000E+03 BIOFAC (

1, 2)

D-5 D-5 Ac-227+Dl ' fish l.500E+Ol l.500E+Ol BIOFAC (

2, 1)

D-5 Ac-227+Dl ' crustacea and mollusks 1.000E+03 l.000E+03 BIOFAC(

2,2)

D-5 D-5 Ac-227+D2 fish 1.500E+Ol l.500E+Ol BIOFAC (

3, 1)

D-5

.Ac-227+D2 ' crustacea and mollusks 1.000E+03 l.OOOE+03 BIOFAC (

3, 2)

D-5 D-5 Ac-227+D3 ' fish 1.500E+Ol 1.500E+Ol BIOFAC (

4' 1)

D-5 Ac-227+D3 ' crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC(

4,2)

D-5 D-5 Ac-227+D4 ' fish 1.500E+Ol 1.500E+Ol BIOFAC(

5, 1)

D-5 Ac-227+D4 crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC (

5, 2)

D-5 D-5 Ac-227+D5 ' fish 1:500E+Ol 1.500E+Ol BIOFAC (

6, 1)

D-5 Ac-227+05 ' crustacea and mollusks l.OOOE+03 1.0QOE+03 BIOFAC (

6, 2)

D-5 D-5 Cs-137+D

' fish 2.000E+03 2.000E+03 BIOFAC(

7' 1)

D-5 Cs-137+D ' crustacea and mollusks 1.000E+02

  • 1. OOOE+02 BIOFAC(

7' 2)

D-5 D-5 Pa-231

' fish l.OOOE+Ol 1.000E+Ol BIOFAC (

8, 1)

D-5 Pa-231

' crustacea and mollusks 1.100E+02 1.100E+02 BIOFAC(

8,2)

D-5 D-5 Pu-239 fish 3.000E+Ol 3.000E+Ol BIOFAC( 14, 1)

D-5 Pu-239

' crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC ( 14' 2)

D-5 D-5 Pu-239+D

' fish 3.000E+Ol 3.000E+Ol BIOFAC( 20,1)

D-5 Pu-239+D crustacea and mollusks 1.000E+02 l.OOOE+02 BIOFAC ( 20,2)

D-5 D-5 Sr-90+D

' fish 6.000E+Ol 6.000E+Ol BIOFAC( 26, 1)

D-5 sr~90+D

' crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 26, 2)

D-5 D-5 U-235+D

' fish l.000Ef01 1.000E+Ol BIOFAC( 27,1)

D-5 U-235+D

' crust ace a and mollusks 6.000E+Ol 6.000E+Ol BIOFAC( 27,2)

D-5

  1. For DCFl(xxx) only, factors are for infinite depth & area.

See ETFG table in Ground Pathway of Detailed Report.

  • Base Case means Default.Lib w/o Associate Nuclide contributions.

Page 4 of 25,

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T" Limit~ 180 days 07/22/2016 11:17 Page 5

Summary RESRAD Default Parameters File C:\\RESRAD_:_FAMILY\\RESRAD\\7*.0\\USERFILES\\AREA 3.1 PU.RAD Menu ROll ROll ROll ROll ROll ROll ROll ROll R0.11 ROll ROll ROll ROll ROll "ROll R012 R012 R012 R012 R012 R012 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R014 R014 R014 R014 R014 R014 R014 R014 Site-Specific Parameter Summary User Parameter Area of contaminated zone (m**2)

Thickness of contaminated zone (m)

Fraction of contamination that is submerged Length paral.lel to aquifer flow (m)

Basic radiation dose limit (mrem/yr)

Time since placement of material (yr)

Times for calculations (yr)

Times for calculations (yr)

Times for calculations (yr)

Times for calculations (yr)

Times for calculations (yr)

Times for calculations (yr)

Times for calculations (yr)

Times for calculauions (yr)

Times for calculations (yr)

Initial principal radionuclide Initial principal radionuclide Initial principal radionuclide Concentration in groundwater Concentration in groundwater Concentration in groundwater Cover depth (m)

(pCi/g)':

(pCi/g):

(pCi/g):

(pCi/L):

(pCi/L):

(pCi/L):

Density of cover material (g/cm**3)

Cover depth erosion rate (m/yr)

Density of contaminated zone (g/cm**3)

Contaminated zone erosion rate (m/yr)

Contaminated zone total porosity Contaminated zone field capacity Cs-137 Pu~239 Sr-90 Cs-137 Pu-239 Sr-90 Contaminated zone hydraulic conductivity (m/yr)

Contaminated zone b parameter Average annual wind speed (m/sec)

Humidity in air (g/m**3)

Evapotranspiration coefficient

  • Precipitation (m/yr)

Irrigation (m/yr)

Irrigation mode Runoff coefficient Watershed area for nearby stream or pond (m**2)

Accuracy for water/soil computations Density of saturated zone (g/cm**3)

Saturated zone total porosity Saturated zone effective porosity Saturated zone field capacity Saturated zone hydraulic conductivity (m/yr)

Saturated zone hydraulic gradient Saturated zone b parameter Water table drop rate (m/yr)

Input Default

6. 4 SOE+04 l.OOOE+OO O.OOOE+OO l.650E+02 2.SOOE+Ol O.OOOE+OO l.OOOE+OO
3. OOOE+OO l.OOOE+Ol 3.000E+Ol l.OOOE+02 3.000E+02 l.OOOE+03 not used not used.

.1. 016E+00 l.091E+OO 5.620E-01 not used not used not used O.OOOE+OO not used not used l.700E+OO O.OOOE+OO 3.600E-01 2.000E-01 l.400E+02 l.400E+OO 2.600E+OO not used 7.800E-01

1. l 60E+OO 4.700E-01 overhead 4.lOOE-01 l.370E+07

.l.OOOE-03 1.700E+OO

3. 600E-01 2.500E-01 2.000E-01 1.400E+03 3.000E-02 not used O.OOOE+OO l.OOOE+04 2.000E+OO 0.000E+OO 1.000E+02 3.000E+Ol O.OOOE+OO 1.000E+OO 3.000E+OO 1.000E+Ol 3.000E+Ol 1.000E+02 3.000E+02 1.000E+03 O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO O:OOOE+OO O.OOOE+OO 1.SOOE+OO
1. OOOE-03 l.SOOE+OO
1. OOOE-03 4.000E-01

.2. OOOE-01 1.000E+Ol 5.300E+OO

. 2. OOOE+OO 8.000E+OO

5. OOOE-01 1.000E+OO 2.000E-01 overhead 2.000E-01 1.000E+06 1.000E-03 1.500E+OO 4.000E-01 2.000E-01
2. OOOE-01.

l.OOOE+02 2.000E-02 5.300E+OO 1.000E-03 Page 5 of 25 Used by RESRAD (If different from user input)

Parameter Name AREA THICKO SUBMFRACT LCZPAQ BRDL TI Tl 2)

T( 3)

TI 4)

T ( 5)

TI 6)

T( 7)

T ( 8)

T( 9)

T(lO)

Sl(7)

Sl(l4)

Sl (26)

Wl I 7).

Wl (14)

Wl (26)

COVE RO DENSCV vcv DENSCZ vcz TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI I DITCH RUNOFF WAREA EPS DENSAQ TPSZ EPSZ FCSZ HCSZ HGWT BSZ VWT

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 r;,, Limit= 180 days 07/22/2016 11:17 Page 6

Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Site-Specific Parameter Summary (continued)

Menu R014 R014 R014 R015 R015 R015 R015 R015 R015 R015 R015 Parameter Well pump intake depth (m below water table)

Model: Nondispersion (ND) or Mass-Balance (MB)

Well pumping rate (m**3/yr)

Number of unsaturated zone strata Unsat. zone 1, thickness (m)

Unsat. zone 1, soil density (g/cm**3)

Unsat. zone 1, total porosity Unsat. zone 1, effective porosity Unsat. zone 1, field capacity Unsat. zone 1, soil-specific b parameter Unsat. zone 1, hydraul~c conductivity (m/yr)

R016 Distribution coefficients for cs-137 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 R016 Contaminated zone (cm**3/g)

Unsaturated zone 1 (cm**3/g)

Saturated zone (cm**3/g)

Leach rate (/yr)

Solubility constant Distribution coefficients for Pu-'239 Contaminated zone (cm**3/g)

Unsaturated zone 1 (cm**3/g)

Saturated zone (cm**3/g)

Leach rate (/yr).

Solubility constant Distribution coefficients for Sr-90 Contaminated zone (cm**3/g)

Unsaturated zone 1 (cm**3/g)

Saturated zone (cm**3/g)

Leach rate (/yr)

Solubility cqnstant Distribution coefficients for daughter Ac-227 Contaminated zone (cm**3/g)

Unsaturated zone 1 (cm**3/g)

Saturated zone (cm**3/g)

Leach rate (/yr)

Solubility constant Distribution coefficie.nts for daughter Pa-231 Contaminated.zone (cm**3/g)

Unsaturated zone 1 (cm**3/g)

Saturated zone (cm**3/g)

Leach rate (/yr)

Solubility constant User Input 5.000E+OO ND 5.720E+03 2.000E+OO

1. 7.00E+OO 3.600E-01 2.500E-01 2.000E-01
1. 4 OOE+OO
1. 4 OOE+02 2.800E+02 2.800E+02 2.800E+02 O.OOOE+OO O.OOOE+OO 2.600E+03 2.600E+03 2.600E+03 O.OOOE+OO 0.000E+OO 5.000E+OO 5.000E+OO 5.000E+OO O.OOOE+OO 0.000E+OO 1.740E+03 1.740E+03
1. 740E+03 O.OOOE+OO O.OOOE+OO 2.040E+03 2.040E+03 2.040E+03 0.000E+OO O.OOOE+OO Default 1.000EtOl ND 2.500E+02 4.000E+OO 1.500E+OO 4.000E-01 2.000E-01 2.000E-01 5.300E+OO 1.000E+Ol 4.600E+03 4.600E+03
4. 600E+03*

O.OOOE+OO 0.000E+OO 2.000E+03 2.000E+03 2.000E+03 0.000E+OO O.OOOE+OO 3.000E+Ol 3.000E+Ol 3.000E+Ol 0.000E+OO O.OOOE+OO 2.000E+Ol 2.000E+Ol 2.000E+Ol O.OOOE+OO 0.000E+OO 5.000E+Ol 5.000E+Ol 5.000E+Ol O.OOOE+OO 0.000E+OO I Page 6 of 25 Used by RESRAD (If different from user input) 5.333E-04 not used 5.746E-05 not used 2.919E-02 not used 8.585E-05 not used 7.323E-05 not used Pararnete~

Name DWIBWT MODEL uw NS H(l)

DENSUZ(l)

TPUZ(l)

EPUZ(l)

FCUZ(l)

BUZ(l)

HCUZ (1)

DCNUCC( 7)

DCNUCU( 7,1)

DCNUCS( 7)

ALEACH( 7)

SOLUBK( 7)

DCNUCC (14)

DCNUCU(14, 1)

DCNUCS (14)

AlEACH(l4)

SOLUBK(l4)

DCNUCC(26)

DCNUCU(26, 1)

DCNUCS (26)

ALEACH(26)

SOLUBK(26)

DCNUCC( 1)

DCNUCU ( 1, 1)

DCNUCS ( 1)

ALEACH( 1)

SOLUBK( 1)

DCNUCC ( 8)

DCNUCU ( 8, 1)

DCNUCS( 8)

ALEACH( 8)

SOLUBK( 8)

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit= 180 days 07/22/2016 11:17 Page 7

Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Site-Specific Parameter Summary (continued)

User Used by RESRAD Menu Parameter Input Default (If different from user input)

R016 R016 R016 R016 R016 R016 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 ROl 7 ROl 7 R017 ROl 7 R017 R017 R017 R017 R017 R017 R017 R017 R018 R018 R018 R018 R018 R018 R018 Distribution coefficients for daughter U-235 Contaminated zone (cm**3/g)

Unsaturated zone 1 (cm**3/g)

Saturated 'zone (cm**3/g)

Leach rate (/yr)

Solubility constant Inhalation rate (m**.3/yr)

Mass loading for inhalation (g/m**J)

Exposure duration Shielding factor, inhalation Shielding factor, external gamma Fraction of time spent indoors Fraction of time spent outdoors (on site)

Shape factor flag, external gamma Radii of shape factor array (used if FS = -1):

Outer annular radius (m), ring 1:

Outer annular radius (m), ring 2:

Outer annular radius (m), ring 3:

Outer annular radius (m), ring 4:

Outer annular radius (m), ring 5:

Outer annular radius (m), ring 6:

Outer annular radius (m), ring 7:

Outer annular radius

(~), ring 8:

Outer annular radius (m), ring 9:

Outer annular radius (m), ring 10:

Outer annular radius (m), ring 11:

Outer annular radius.(m), ring 12 :.

Fractions of annular areas within AREA:

Ring 1

Ring 2

Ring 3

Ring 4

Ring 5

Ring 6

Ring 7

Ring 8

Ring 9

Ring 10 Ring 11 Ring 12 Fruits, vegetables and grain consumption (kg/yr)

Leafy vegetable consumption (kg/yr)

Milk consumption (L/yr)

Meat and poultry consumption (kg/yr)

Fish consumption (kg/yr)

Other seafood consumption (kg/yr)

Soil ingestion rate (g/yr) 3.500E+Ol 3.500E+Ol 3.500E+Ol O.OOOE+OO O.OOOE+OO

8. 4 OOE+03
1. 4 80E-05 l.OOOE+OO 1.000E+OO 2.730E-Ol 6.600E-01 2.500E-01 l.OOOE+OO not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used l.120E+02 2.lOOE+Ol 2.330E+02 6.500E+Ol 9.000E+OO 0.000E+OO 1.830E+Ol 5.000E+Ol 5.000E+Ol 5.000E+Ol O.OOOE+OO 0.000E+OO 8.400E+03 1.000E-04 3.000E+Ol 4:000E-01 7.000E-01
5. OOOE-01

.2.500E-01 1.000E+OO 5.000E+Ol

7. 071E+Ol O.OOOE+OO O.OOOE+OO 0.000E+OO O.OOOE+OO
0. OOOE+OO O.OOOE+OO 0.000E+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO
1. OOOE+OO 2.732E-01 O.OOOE+OO O.OOOE+OO O.OOOE+OO 0.000E+OO 0.000E+OO
0. OOOE+O.O O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO
1. 600E+02 1.400E+Ol 9.200E+Ol 6.300E+01 5.400E+OO
9. 000E-01 3.650E+Ol Page 7 of 25 4.254E-03 not used

>0 shows circular AREA.

Parameter Name DCNUCC(27)

DCNUCU (27, 1)

DCNUCS (27)

ALEACH(27)

SOLUBK(27)

INHALR MLINH ED SHF3 SHFl FTND FOTD FS RAD SHAPE ( 1 )

RAD::: SHAPE ( 2 )

RAD SHAPE( 3)

RAD:::SHAPE( 4)

RAD _SHAPE ( 5)

RAD_SHAPE ( 6)

RAD_SHAPE( 7)

RAD_SHAPE( 8)

RAD SHAPE ( 9)

RAD::: SHAPE ( 10)

RAD SHAPE (11)

RAD:::SHAPE(12)

FRACA( 1)

FRACA( 2)

FRACA( 3)

FRACA( 4)

FRACA( 5)

FRACA( 6)

FRACA( 7)

FRACA( 8)

FRACA( 9)

FRACA(lO)

FRACA(ll)

FRACA(12)

DIET (1)

DIET(2)

DIET(3)

DIET(4)

DIET(5)

DIET ( 6)

SOIL

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit= 180 days 07/22/2016 11:17 Page Summary RESRAD Default Parameters File C: \\RESRAD_FAMILY\\RESRAD\\ 7. 0\\USERF.ILES\\AREA 3.1 PU. RAD Site-Specific Parameter Summary (continued)

Menu R018 R018 R018 R018 R018 R018 R018 R018 R018 R019 R019 R019 R019 R019 R019 R019 R019

'R019 R019 R019 R019 R19B R19B R19B Rl9B R19B R19B R19B R19B R19B R19B R19B R19B R19B R19B R19B R19B Cl4 Cl4 Cl4 Cl4 Cl4 Cl4 CliJ Cl4 Cl4 Parameter Drinking water intake IL/yr)

Contamination fraction of drinking water Contamination fraction of household water Contamination fraction of livestock water Contamination fraction of irrigation water Contamination fraction of aquatic food Contamination fraction of plant food Contamination fraction of meat Contamination fraction of milk Livestock fodder intake for meat (kg/day)

Livestock fodder intake for milk (kg/day)

Livestock water intake for meat (L/day)

Livestock water intake for milk IL/day).

Livestock soil intake (kg/day)

Mass loading for foliar deposition (g/m**3)

Depth of soil mixing layer (m)

Depth of roots (m)

Drinking water fraction from ground water Household water fraction from ground water Livestock water fraction from ground water Irrigation fraction from ground water Wet weight crop yield for Non-Leafy I kg/m* *2 J Wet weight crop yield for Leafy (kg/m**2)

Wet weight crop yield for Fodder (kg/m**2)

Growing Season for Non-Leafy (years)

Growing Season for Leafy (years)

Growing Season for Fodder (years)

Translocation Factor for Non-Leafy Translocation Factor for Leafy Translocation Factor for Fodder Dry Foliar Interception Fraction for Non-Leafy.

Dry Foliar Interception Fraction for Leafy Dry Foliar Interception Fraction for Fodder Wet Foliar Interception Fraction for Non-Leafy Wet Foliar Interception Fraction for Leafy Wet Foliar Interception Fraction for Fodder Weathering Removal Constant for Vegetation C-12 concentration in water (g/cm**3)

C-12 concentration in contaminated soil (g/g)

Fraction of vegetation carbon from soil Fraction of vegetation carbon from air C-14'evasion layer thickness in soil (m)

C-14 evasion flux rate from soil (1/sec)

C-12 evasion flux rate from soil (1/sec)

Fraction of grain in beef cattle feed*

Fraction of grain i.n milk cow feed User Input 7.300E+02 l.OOOE+OO not used l.OOOE+OO 1.000E+OO 1.000E+OO 1.000E+OO 1.000E+OO 1.000E+OO 2.730E+Ol

6. 420E+Ol 5.000E+Ol 1.600E+02 5.000E-01 4.000E-04 1.SOOE-01 9.000E-01 1.000E+OO not used 1.000E+OO 1.000E+OO
1. 750E+OO l.500E+OO 1.lOOE+OO
1. 700E-01 2.SOOE-01 8.000E-02
1. OOOE-01 1:000E+OO 1.000E+OO 2.500E-01 2.SOOE-01 2.500E-01 2.500E-01 6.700E-01 2.500E-01
1. 800E+Ol
  • not used not used not used not used not used not used not used not used not used Default 5.100E+02 1.000E+OO 1.000E+OO 1.000E+OO 1.000E+OO 5.000E-01

-1

-1

-1 6.SOOE+Ol 5.500E+Ol 5.000E+Ol l.600E+02 5.000E-01 1.000E-04 l.500E-01 9.000E-01 1.000E+OO 1.000E+OO 1.000E+OO 1.000E+OO 7.000E-01 1.500E+OO 1.lOOE+OO

1. 700E-01 2.500E-01 8.000E-02
1. OOOE-01 l.OOOE+OO l.OOOE+OO 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.000E+Ol 2.000E-05 3.000E-02 2.000E-02 9.800E-01 3.000E-01 7.000E-07 1.000E-10 8.000E-01 2.000E-01 Page 8 of 25 Used by RESRAD (If different from user input)

Parameter Name DWI FDW FHHW FLW FIRW FR9 FPLANT FMEAT FM ILK LFI5 LFI6 LWI5 LWI6 LSI MLFD DM DROOT FGWDW FGWHH FGWLW FGWIR YV(l)

YV(2)

YV(3)

TE(l)

TE(2)

TE(3)

TIV(l)

TIV(2)

TIV(3)

RDRY ( 1 I RDRY(2)

RDRY(3)

RWET(l)

RWET (2)

RWET (3)

WLAM Cl2WTR Cl2CZ CS OIL CAIR DMC EVSN REV SN AVFG4 AVFG5

Appendix H38: RESRAD 7.0 Output for'Area 3.1 Pu-239 RESRAD,' Version 7.0 Tu Limit= 180 days 07/22/2016 11:17 Page 9

summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD site-Specific Parameter Surrunary (continued)

Menu STOR STOR STOR STOR STOR STOR STOR STOR STOR STOR R021 R021 R021 R021.

R021 R021 R021 R021 R02_1.

R021 R021 R021 R021 R021 R021 R021 R021 TITL TITL TITL Parameter Storage times of contaminated foodstuffs (days):

Fruits, non-leafy vegetables, and grain Leafy vegetables Milk Meat and poultry Fish Crustacea and mollusks Well water Surface water Livestock fodder Thickness of building foundation Im)

Bulk density of building foundation (g/cm**3)

Total porosity of the cover material Total porosity of the building foundation Volumetric water content of the cover material Volumetric water content of the foundation Diffusion coefficient for radon gas (m/sec):

in cover material in foundation material in contaminated zone soil Radon vertical dimension of mixing (m)

Average building air exchange rate (1/hr)

Height of the building (room)

(m)

Building interior area factor Building depth below ground surface (m)

Emanating power of Rn-222 gas Emanating power of Rn-220 gas Number of graphical time points Maximum number of integration points for dose Maximum number of integration points for risk Summary of Pathway Selections Pathway 1

external gamma 2

inhalation (w/o radon}

3 plant ingestion 4

meat ingestion 5

milk ingestion 6

aquatic foods 7

drinking water 8

soil ingestion radon Find peak pathway doses User Selection active active active active active active active active suppressed

-suppressed User Input

1. 400E+Ol 1.000E+OO 1.000E+OO 2.000E+Ol 7.000E+OO 7.000E+OO 1.000E+OO 1.000E+OO 4.500E+Ol not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used 32 17 257 Default
1. 400E+Ol l.OOOE+OO l.OOOE+OO 2.000E+Ol 7.000E+OO 7.000E+OO 1.000E+OO 1.000E+OO 4.500E+Ol
1. 500E-01 2.400E+OO 4.000E-01
1. OOOE-01 5.000E-02 3.000E-02 2.000E-06 3.000E-07 2: OOOE-0"6 2.000E+OO 5.000E-01 2.500E+OO O.OOOE+OO

-1.000E+OO 2.500E-01

1. 500E-01 Page 9 of 25 Used by RESRAD (If different from user input)

Parameter Name STOR T(l)

STOR-T(2)

STOR-T(3)

STOR-T(4)

STOR-T(5)

STOR-T(6)

STOR-T(7)

STOR-T(8)

STOR::)(9)

FLOORl DENS FL TPCV TPFL PH20CV PH20FL DIFCV DIFFL DIFCZ HMIX REXG HRM FAI DMFL EMANA(l)

EMANA(2)

NPTS LYMAX KYMAX

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit= 180 days 07/22/2016 11:17 Page 10 Summary RESRAD Default Parameters File

C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Contaminated Zone Dimensions Area:

64500.00 square meters Thickness:

1.00 meters Cover Depth:

0.00 meters Initial Soi*l Concentrations, pCi/g Cs-137 Pu-239 Sr-90

1. 016E+OO
1. 091E+OO 5.620E-01 Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+Ol mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years):

TDOSE (t):

M(t):

O.OOOE+OO l.OOOE+OO 3.000E+OO 7.237E+OO 6.954E+OO 6.427E+OO 2.895E-01 2.782E-01 2.571E-01 l.OOOE+Ol 4.932E+OO l.973E-01 3.000E+Ol 2.567E+OO l.027E-01 l.OOOE+02 9.482E-01 3.793E-02 Maximum TDOSE(t):

7.237E+00 mrem/yr at t = 0.000E+OO years Page 10 of 25 3.000E+02 5.912E-Ol 2.365E-02 l.000E+03

5. 54 9E-01 2.220E-02

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit= 180 days 07/22/2016 11:17 Page 11 summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Total Dose Contributions TDOSE (i, p, t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 0.000E+OO years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

Cs-137

1. 422E+O.O 0.1965 7.081E-07 0.0000 O.OOOE+OO 0.0000. 2. 671E-01 0.0369 1.559E-01 0. 0215 2.873E-01 0.0397 8.361E-04 0.0001 Pu-239 l.357E-04 0.0000 l.035E-02 0. 0014 O.OOOE+OO 0.0000 5.163E-01 0. 0713 1.325E-02 0.0018 5.091E-04 0.0001 6.431E-02 0.0089 Sr-90 5.613E-03 0.0008 1.583E-05 0.0000 0.000E+OO 0.0000 3:340E+OO 0. 4 615
3. 796E-01 0.0525
7. 726E-01 0. 1068 l.393E-03 0.0002 Total
1. 427E+OO 0.1972
1. 036E-02 0. 0014 0.000E+OO 0.0000 4.123E+OO 0.5697 5.488E-01 0.0758 1.060E+OO 0.1465 6.654E-02 0. 0092 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t O.OOOE+OO years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/y:i:

fract.

mrem/yr fract.

Cs-137 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 2.133E+OO 0.2947 Pu-239 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O,OOOE+OO 0.0000 O.OOOE+OO 0.0000 6.048E-01 0.0836 Sr-90 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000. 0. OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 4.499E+OO 0.6217 Total O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 7.237E+OO 1. 0000

  • Sum a*f all water independent and dependent pathways.

Page 11of25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit~ 180 days 07/22/2016 11:17 Page 12 Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t

~ l.OOOE+OO years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.

Cs-137 Pu-239 Sr-90 Total l.389E+OO 0.1997 l.357E-04 0.0000 5.321E-03 0.0008

1. 394E+OO 0. 2005 mrem/yr fract.

6.917E-07 0.0000 l.035E~02 0.0015 l.501E-05 0.0000 l.036E-02 0.0015 mrem/yr fract.

O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 Total Dose Contributions TDOSE(i,p,t) mrem/yr fract.

2.609E-01 0.0375 5.162E-01 0.0742 3.167E+OO 0.4554 3.944E+OO 0.5671 mrem/yr fract.

l.523E-01 0.0219

1. 325E-02 0. 0019 3.601E-01 0.0518 5.2S7E-01 0.0756 for Individual Radionuclides (i) and As mrem/yr and Fraction of Total Dose At t l.OOOE+OO years Water Dependent Pathways Water Fish

. Radon Plant Meat Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

  • cs-137 0.000E+OO 0.0000 0.000E+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 Pu-239 0.000E+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO. 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 Sr-90 O.OOOE+OO 0.0000 0.000E+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 0.000E+OO 0.0000 Total O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000
  • Sum of all water independent and dependent pathways.

Page 12 of 25 mrem/yr fract.

2.806E~Ol b.0403 5.090E-04 0.0001 7.328E-01 0.1054 l.014E+OO 0.1458 Pathwa.ys (p)

Milk mrem/yr fract.

O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 0.000E+OO 0.0000 O.OOOE+OO 0.0000 Soil mrem/yr fract.

8:167E-04 0.0001 6.431E-02 0.0092 l.320E-03 0.0002 6.644E-02 0.0096 All Pathways*

mrem/yr fract.

2.083E+OO 0.2996 6.048E-01 0.0870 4.266E+OO 0.6135 6.954E+OO 1.0000

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T'< Limit= 180 days 07/22/2016 11:17 Page 13 summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Total Dcise Contributions TDOSE(i,p,t) for Indiv'idual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 3.000E+OO years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

Cs-137 l.325E+OO 0.2061 6.599E-07 0.0000 O.OOOE+OO 0.0000

2. 4 90E-01 0.0387
1. 453E-01 0.0226 2.677E-01 0.0417 7.792E-04 0.0001 Pu-239
1. 357E-04 0.0000 l.034E-02 0.0016 0.000E+OO 0.0000 5.162E-01 0.0803 l.325E-02 o.002i.

5.089E-04 0.0001

6. 430E-02 0.0100 Sr-90 4.784E-03 0.0007
1. 34 9E-05 0.0000 O.OOOE+OO 0.0000 2.847E+oo 0.4429 3.237E-01 0.0504 6.587E-Ol 0.1025 l.187E-03 0.0002 Total l.330E+00 0.2069 l.036E-02 0.0016 O.OOOE+OO 0.0000 3.612E+OO *0.5619 4.823E-01 0.0750 9.270E-01 0.1442
6. 626E-02 0.0103 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t 3.000E+OO years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

Cs-137 O.OOOE+OO 0.0000 O.OOOE+OO 0.000Q O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 l.988E+OO 0.3092 Pu-239 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0:0000 O.OOOE+OO 0.0000. O.OOOE+OO 0.0000 6.047E-01 0.0941 Sr-90 O.OOOE+OO 0.0000 0.000E+OO 0.0000 0.000E+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 3.835E+OO 0.5967 Total O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000

6. 427E+00 1.0000
  • Sum of all water independent and dependent pathways.

Page 13 of 25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0

!'->Limit= 180 days 07/22/2016 11:17 Page 14 Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = l.OOOE+Ol years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract.

mrem/yr fract.

Cs-137 Pu-239 Sr-90 l.124E+OO 0.2279 5.598E-07 0.0000 l.356E-04 0.0000 l.034E-02 0.0021 3.295E-03 0.0007" 9.293E-06 0.0000 mrem/yr fract.

0. OOOE+.00 0. 0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 mrem/yr fract.

2.112E-01 0.0428 5.158E-01 0.1046

1. 961E+OO 0. 3976 mrern/yr fraci:.

l,233E-01 0.0250

1. 324E-02 0. 0027 2.230E-01 0.0452 mrem/yr fract.

rnrem/yr fract.

2.271E-01 0.0460 *6.609E-04 0.0001 5.086E-04 0.0001 6.426E-02 0.0130 4.537E-Ol 0.0920 8.175E-04 0.0002 Total l.127E+OO 0.2286 l.035E-02 0.0021 O.OOOE+OO 0.0000 2.688E+OO 0.5450 3.595E-01 0.0729 6.813E-01 0.1381 6.574E-02 0.0133 Radio-Nuclide Cs-137 Pu-239 Sr-90 Total Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t l.OOOE+Ol years Water Dependent Pathways Water Fish Radon Plant Meat Milk.

mrern/yr fract.

rnrem/yr fract.

O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 rnrern/yr fract..

rnrem/yr fract.

rnrem/yr fract.

O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+00.0.0000 O.OOOE+OO 0.0000. 0.000E~OO 0.0000 mrem/yr fract.

O.OOOE+OO 0.0000 O.OOOE+00.0.0000 O.OOOE+OO 0.0000 All Pa.thways*

mrern/yr fract.

1. 68 6E+OO 0. 3419 6.043E-01 0.1225 2.641E+OO 0.5356 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO o.*oooo O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 4.932E+OO 1.0000
  • Sum of all water independent and dependent pathways.

Page 14 of 25.

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 l"' Limit= 180 days 07/22/2016 11:17 Page 15 summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Total Dose Contributions TDOSE(i,p,t) for *Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Tota-1 Dose At t =. 3. OOOE+Ol years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil R.adio-Nuclide mrem/yr fract.

mrem/yr fr21ct.

mrem/yr fract.

mrem/yr

  • fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

Cs-137 7.Q23E-01 0.2736 3.498E-07 0.0000 O.OOOE+OO 0.0000 l.320E-01 0.0514 7.703E-02 0.0300

1. 419E-01 0.0553 4.130E-04 0.0002 Pu-239
1. 354E-04 0.0001 l.032E-02 0.0040 O.OOOE+OO 0.0000 5.150E-01 0.2006 l.322E-02 0.0051 5.078E-04 0. 0002 6: 415E-02 0.0250 Sr-90 l.135E-03 0.0004 3.202E-06 0.0000 O.OOOE+OO 0.0000 6.757E-01 0. 2632 7.683E-02 0.0299 l.563E-01 0.0609 2.817E-04 0.0001 Total 7.035E-01 0.2741 l.032E-02 0.0040 O.OOOE+OO 0.0000 l.323E+OO 0.5152 l.671E-01 0.0651 2.988E-01 0.1164 6.484E-02 0.0253 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t 3.000E+Ol years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract.

mrem/yr fract, mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

Cs-137 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 0.1JOOE+00 0.. 0000 O.OOOE+OO 0.0000 1.054E+00 0.4104 Pu-239 O.OOOE+OO 0.0000 O.OOOE+OO 0. oo.oo O.OOOE+OO 0.0000 O.OOOE+OO 0. 0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 6.033E-01 0.2350 Sr-90 0.000E+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0. 0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 9.103E-01 0.3546 Total O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 2.567E+OO 1.0000

  • Sum of all water independent and dependent pathways.

Page 15 of 25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit= 180 days 07/22/2016 11:17 Page 16 Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and As mrem/yr and Fraction of Total Dose At t = l.OOOE+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

Cs-137 l.354E-01 0. 1428 6.746E-08 0.0000 O.OOOE+OO 0.0000 2.545E-02 0.0268

1. 486E-02 0.0157 Pu-239
1. 34 6E-04 0.0001
1. 026E-02 0.0108 O.OOOE+OO 0.0000 5.119E-01 0.5398
1. 314E-02 0.0139 Sr-90 2.728E-05 0.0000 7.693E-08 0.0000 O.OOOE+OO o. ooo*o
1. 623E-02 0. 0171
1. 84 6E-03 0.0019

=

Total

1. 356E-01 0.1430
1. 026E-02 0.0108 O.OOOE+OO 0.0000 5.535E-01 0.5838 2.984E-02 0.0315 Pathways (p)

Milk Soil mrem/yr fract.

mrem/yr fract.

2.737E-02 0.0289 7.966E-05 "0.0001 5.047E-04 0.0005

  • 6.376E-02 0.0672 3.756E-03 0.0040 6.768E~06 0.0000 3.163E-02 0.0334 6.385E-02 0.0673 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

Cs-137 O.OOOE+OO 0.0000 0.. OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 2.032E-01 0. 2143 Pu-239 0.000E+OO o.ouoo O.OOOE+OO 0.0000 0.000E+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 5.997E-01 0.6324 Sr-90 6.740E-02 0. 0711

1. l 77E-03 0.0012 0.000E+OO 0.0000 2.697E-02 0.0284 8~420E-03 0.0089 1.954E-02 0.0206
1. 454E-01 0.1533 Total 6.740E-02 0. 0711 l.177E-03 0.0012 O.OOOE+OO 0.0000 2.697E-02 0.0284 8.420E-03 0.0089 l.954E-02 0.0206
9. 482E-01 1. 0000
  • sum of all water independent and dependent pathways.

Page 16 of 25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit= 180 days 07/22/2016 11:17 Page 17

.Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (pl As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

m7em/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

Cs-137 l.229E-03 0. 0021 6.123E-10 0.0000 0.. OOOE+OO 0.0000 2.310E-04 0.0004

1. 34 8E-04 0.0002 2.484E-04 0.0004 7.230E-07 0.0000 Pu-239 l.323E-04 0.0002 l.008E-02 0. 0171 O.OOOE+OO 0.0000 5.031E-Ol 0.8509
1. 291E-02 0.0218 4.961E-04 0.0008 6.267E-02 0.1060 Sr-90 6.442E-10 0.0000
1. 817E-12 0.0000 0.000E+OO 0.0000 3.833E-07 0.0000 4.359E-08 0.0000 8.870E-08 0.0000
1. 598E-10 0.0000 Total
1. 362E-03 0.0023 l.008E-02 0.0171 O.OOOE+OO 0.0000 5.033E-Ol 0.8513
1. 305E-02 0. 0221 7.446E-04 0. 0013 6.267E-02 0,.1060 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t 3.000E+02 years Water Dependent Pathways

. Water Fish Radon Plant Meat Milk All Pathways*

Radio-Nuclide mrem/yr fr act.

mr;em/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

Cs-137 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 0.000E+OO 0.0000

0. OOOE+.00 0.0000 O.OOOE+OO 0.0000
1. 844E-03 0. 0031 Pu-239 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 5.894E-01 0.9969 Sr-90 l.592E-06 0.0000 2.780E-08 0.0000 O.OOOE+OO 0.0000 6.370E-07 0.0000 l.989E-07 0.0000 4.616E-07 0.0000 3.433E-06 0.0000 Total l.592E-06 0.0000 2.780E-08 0.0000 0.000E+OO 0.0000
6. 370E'...07 0.0000 l.989E-07 0.0000 4.616E-07 0.0000 5.912E-01 1. 0000
  • Sum of all water independent and dependent pathways..

Page 17 of 25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T'> Limit= 180 days 07/22/2016 11:17 Page 18 Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)

Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr* fract.

mrem/yr "fract.

mrem/yr tract.

Cs-137

8. 759E-11 0.0000 4.362E-17 0.0000 O.OOOE+OO 0.0000
1. 646E-11 0.0000 9.607E-12 0.0000
1. 770E-ll 0.0000 5.151E-14 0.0000 Pu-239
1. 246E-04 0.0002
9. 4 92E-03 0. 0171 O.OOOE+OO 0.0000.4. 736E-01 0.8536
1. 216E-02 0.0219 4.670E-04 *0.0008 5.900E-02 0.1063 Sr-90 4.124E-26 0.0000 l.163E-28 0.0000 O.OOOE+OO 0.0000 2.454E-23 0.0000 2.791E-24 0.0000 5.679E-24 0.0000
1. 023E-26 0.0000 Total
1. 246E-04 0.0002
9. 4 92E-03 0. 0171 O.OOOE+OO 0.0000 4.736E-01 0.8536
1. 216E-02 0.0219
4. 670E-04 0.0008 5.900E-02 0.1063 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)

As mrem/yr and Fraction of Total Dose At t

1. OOOE+03 years Water Dependent Pathways Water Fl sh Radon Plant*

Meat Milk All Pathways*

Radio-Nuclide mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fract.

mrem/yr fr act.

mrem/yr fract.

mrem/yr fract.

Cs-137

0. OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+oo 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000 O.OOOE+OO 0.0000
1. 314E-10 0.0000 Pu-239 2.614E-07 0.0000 7.637E-10 0.0000 O.OOOE+OO 0.0000 1.0lOE-07 0.0000
1. 476E-09 0.0000 2.223E-08 0.0000 5.549E-01 1.0000 Sr-90
1. 019E-22 0.0000
1. 779E-24 0.0000 O.OOOE+OO 0.0000. 4. 078E'-23 0.0000
1. 273E-23 0. 0000_

2.955E-23 0.0000 2.198E-22 0.0000 Total 2.614E-07 0.0000 7.637E-10 0.0000 O.OOOE+OO 0.0000 l.OlOE-07 0.0000 l.476E-09 0.0000 2.223E-08 0.0000 5.549E-01 1. 0000

  • Sum of all water independent and dependent pathways.

Page 18 of 25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, version 7.0

!"> Limit ~ 180 days 07/22/2016 11: 17 Page 19 Summary : RESRAD Default Parameters File

C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated 0

Parent Product Thread DSR (j, t) At Time in Years (mrem/yr)/(pCi/g)

(i)

(j)

Fraction O.OOOE+OO 1.000E+OO 3.000E+OO 1. OOOE+Ol 3. OOOE+Ol 1.000E+02 3. 00.0E+02 1.000E+03 Cs-137+D Cs-137+D 1.000E+OO 2.099E+OO 2.051E+OO 1. 956E+OO 1.659E+OO 1. 037E+OO 2.000E-01 1. 815E-03 l.293E-10 OPu-239 Pu-239 5.901E-04 3.271E-04 3.271E-04 3. 271E-04 3.269E-04 3.263E-04 3.243E-04 3.188E-04 3.00lE-04 Pu-239 U-235+D 5.901E-04 1.274E-13 3.838E-13 8.936E-13 2.643E-12 7.359E-12 2. 097E-11 4. 302E-ll 2.621E-10 Pu-239 Pa-231 5.901E-04 3.166E-17 2.340E-16 1. 263E-15 1.133E-14 9.314E-14 9.172E-13 6.329E-12 3. 641E-ll Pu-239 Ac-227+D 5.901E-04 1.393E-19 1. 795E-l8. 1.882E-17 4.437E-16 8.995E-15 1. 935E-13 1. 941E-12 1. 414E-ll Pu-239 WSR(j)

3. 271E-04 3. 271E-04 3.271E-04 3.269E-04 3.263E-04 3.243E-04 3.188E-04 3. OOlE-04 OPu-239 Pu-239 1.633E-06 9.054E-07 9.053E-07 9 :052E-:07 9.046E-07 9.031E-07 8.976E-07 8.823E-07 8.306E-07 Pu-239 U-235+D 1.633E-06 3.525E-16 1. 0°62E-15 2.473E-15 7.:i16E-15 2.037E-14 5.805E-14 1.191E-13 7.253E-13 Pu-239 Pa-231 1.633E-06 8.762E-20 6.476E-19 3.496E-18 3.135E-17 2.578E-16 2.538E-15 1. 752E-14 l.008E-13 Pu-239 Ac-227+Dl 1.633E-06 2.521E-22 3. 962E-21 4.665E-20 1. lBOE-18 2. 453E-17 5.325E-16 5.354E-15 3.905E-14 Pu-239 WSR(j) 9.054E-07 9.053E-07 9.052E-07 9.046E-07 9.031E-07 8.976E-07 8.823E-07 8 *. 306E-07 OPu-239 Pu-239 8.257E-06 4.577E-06 4.577E-06 4. 576E-06 4.573E-06 4. 566E-06 4.538E-06 4.461E-06 4.199E-06 Pu-239 U-235+D 8.257E-06 1.782E-15 5.370E-15 1. 250E-14 3.699E-14 1. 030E-13 2. 935E-13 6.020E-13 3.667E-12 Pu-239 Pa-231 8.257E-06 4.430E-19 3.274E-18 1. 767E-17 1. 585E-16 1. 303E-15 1. 283E-14 8.855E-14 5.095E-13 Pu-239 Ac-227+D2 8.257E-06 1.239E-21 1.950E-20 2.297E-19 5.816E-18 1.209E-16 2.624E-15 2.638E-14 1.930E-13 Pu-239 EDSR(j) 4.577E-06 4.577E-06 4. 576E-06 4.573E-06 4.566E-06 4:538E-06 4.461E-06 4.199E-06 OPu-239
Pu-239 2.285E-08 l.267E-08 1. 267E-08 1. 267E-08 1. 266E-08 1. 2 64E-08 1.256E-08 1.235E-08 1.162E-08 Pu-239 U-235+D 2.285E-08
4. 932E-18 1. 486E-l 7 3. 4 60E-17 1.024E-16 2.850E-16 8.122E-16 1. 666E-15 1.015E-14 Pu-239 Pa-231 2.285E-08
1. 226E-21 9.062E-21 4. 891E-20 4.386E-19 3.607E-18 3.552E-17 2.451E-16 1. 410E-15 Pu-239 Ac-227+D3 2.285E-08 3.436E-24 5.407E-23 6.370E-22 1.613E-20 4.351E-19 7.276E-18 7.315E-17 5.349E-'16 Pu-239 EDSR(j) 1.267E-08 1.267E-08 1. 267E-08 1.266E-08 1. 264E-08 1. 256E-08 1. 235E-08 1.162E-08 OPu-239 Pu-239 4.954E-10 2.747E-10 2.746E-10 2.746E-10 2.744E-10 2.740E-10 2.723E-10 2.677E-10 2.520E-10 Pu-239 U-235+D 4.954E-10
1. 069E-19 3.222E-19 7.503E-19 2.219E-18 6.179E-18 1.761E-17 3.612E-17 2.200E-16 Pu-239 Pa-231 4.954E-10 2.658E-23 1.965E-22 1. 060E-21 9.509E-21 7. 820E-20 7.701E-19 5.313E-18 3.057E-17 Pu-239 Ac-227+D4 4.954E-10 6.634E-26 1. 048E-24 l.237E-23 3.134E-22 6. 516E-21 1. 415E-19 l.422E-18 1. 049E-17 Pu-239 EDSR(j) 2.747E-10 2.746E-10 2.746E-10 2.744E-10 2.740E-10 2. 723E-10 2. 677E-10* 2.520E-10 OPu-239 Pu-239
1. 371E-12 7.602E-13 7. 601E-13 7. 600E-13 7. 595E-13 7. 582E-13 7.536E-13 7. 408E-13 6.974E-13 Pu-239 U-235+D
1. 371E-12

~.959E-22 8.918E-22 2. 076E-21 6.142E-21 1. 710E-20 4.873E-20 9.997E-20 6.089E-19

1. 371E-12
7. 356E-26 5. 437E-25 2.935E-24 2.632E-23 2.164E-22 2.131E-21 1. 471E-20 8.461E-20 Pu-239 Ac-227+D5* 1.371E-12
1. 840E-28 2.907E-27 3.431E-26 8.693E-25 1. 807E-23 3.924E-22 3.945E-21 2.908E-20 Pu-239 EDSR(j) 7.602E-13 7.601E-13 7.600E:-13 7. 595E-13 7.582E-13 7. 536E-13 7.408E-13 6. 974E-13 0Pu-239+D Pu-239+D 9,829E-01 5.449E-01 5.449E-01 5.448E-01 5. 444E-01 5.435E-01 5.402E-01 5.310E-01 4.999E-01 Pu-239+D U-235+D 9.829E-01 2.121E-10 6.393E-10 1. 488E-09 4.403E-09 1. 226E-08 3.493E-08 7.166E-08 4. 365E-07 Pu-239+D Pa-231 9.829E-01 5.273E-14 3.898E-13 2.. 104E-12 1. 887E-11 1.551E-10 l.528E-09 1. 054E-08 6. 065E-08 Pu~239+D Ac-227+D 9.829E-01 2.320E-16 2.989E-15 3.135E-14 7. 391E-13 1. 4 98E-ll 3.223E-10 3.233E-09 2.355E-08 Pu-239+D EDSR(j) 5.449E-:01 5.449E-01 5.448E-01 5. 444E-01 5. 4 35E-01 5.402E-01 5.310E-01 4.999E-01 Page 19 of 25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RES RAD, Version 7.0 T~ Limit = 180 days 07/22/2016 11: 17 Page 20 Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated 0

Parent Product Thread DSR (j, t) At Time in Years (mrem/yr)/(pCi/g)

(i)

(j)

Fraction O.OOOE+OO 1.000E+OO 3.000E+OO 1.000E+Ol 3.000E+Ol Pu-239+D Pu-239+D

2. 720E-03 l.508E-03 1.508E-03 1.508E-03 1.507E-03 l.504E-03 Pu-239+D U-235+D 2.720E-03 5.871E-13 1. 769E-12 4.119E-12 l.219E-11 3. 393E-11 Pu-239+D Pa-231
2. 720E-03 l.459E-16 1. 079E-15 5.823E-15 5.221E-14 4.294E-13 Pu-239+D Ac-227+Dl
2. 720E-03 4.199E-19 6.599E-18 7.770E-17 1. 966E-15 4. 086E-14 Pu-239+D

~DSR(j) 1.508E-03 l.508E-03 1.508E-03 1. 507E-03* 1. 504E-03 0Pu-239+D Pu-239+D

1. 375E-02.7. 624E-03 7.624E-03 7.623E-03 7.618E-03 7.605E-03 Pu-239+D U-235+D
1. 375E-02 2.968E-12 8.945E-12 2. 083E-ll 6.161E-11 1.715E-~0 Pu-239+D Pa-231
1. 375E-02 7.378E-16 5.454E-15 2.944E-14 2.640E-13 2.171E-12 Pu-239+D Ac-227+D2 1.375E-02 2.064E-18 3. 247E-17 3.827E-16 9.687E-15 2. 013E-13 Pu-239+D

. EDSR(j) 7.624E-03 7.624E-03 7.623E-03 7.618E-03 7.605E-03 0Pu-239+D Pu-239+D

3. 806E-05
2. llOE-05 2. llOE-05 2. llOE-05 2.108E-05 2.105E-05 Pu-239+D U-235+D 3.806E-05 8.215E-15 2.476E-14 5. 764E-14 1. 705E-13 4.747E-13 Pu-239+D Pa-231
3. 806E-05 2.042E-18 1. 509E-17 8.148E-17 7.306E-16 6.008E-15 Pu-239+D Ac-227+D3 3.806E-05
5. 724E-21 9. 006E-20 1.061E-18 2.686E-17 5.582E-16 Pu-239+D EDSR(j)
2. llOE-05 2. llOE-05 2.llOE-05 2.108E-05 2.105E-05 0Pu-239+D Pu-239+D 8.252E-07 4.575E-07 4.575E-07 4.574E-07 4.571E-07 4.563E-07 Pu-239+D U-235+D 8.252E-07
1. 781E-16 5.367E-16 1. 250E-15 3.697E-15 1.029E-14 Pu-239+D Pa-231 8.252E-07 4.427E-20 *3. 272E-19 1. 766E-18 1. 584E-17 1. 303E-16 Pu-239+D Ac-227+D4 8.252E-07 1.105E-22 l.745E-21 2.060E-20 5.221E-19 1. 085E-17 Pu-239+D EDSR(j) 4.575E-07 4.575E-07 4.574E-07 4. 571E-07 4.563E-07 0Pu-239+D Pu-239+D 2.284E-09. 1. 266E-09 1. 266E-09 1. 266E-09 1. 265E-09 1. 263E-09.

Pu-239+D U-235+D

2. 284E-09 4.930E-19 1. 486E-18 3.459E-18 1.023E-17 2.848E-17 Pu-239+D Pa-23-1
2. 284E-09 1.225E-22 9.057E-22 4.889E-21 4.384E-20 3.605E-19 Pu-239+D Ac-227+D5 2.284E-09 3.065E-25 4.841E-24 5.714E-23 1. 448E-21 3.0lOE-20 Pu-239+D EDSR(j)
1. 266E-09 1. 266E-09 1. 266E-09 1. 265E-09 1. 263E-09 0Sr-90+D Sr-90+D 1.000E+OO 8.005E+OO 7.591E+OO 6. 824E+OO 4.700E+OO 1.620E+OO The DSR includes contributions from associated (half-life ~ 180 days) daughters.

ONuclide (i) t= O.OOOE+OO Cs-137

1. 191E+Ol Pu-239 4.509E+Ol Sr-90 3.123E+OO
  • At.specific activity Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Li~t = 2.500E+Ol mrem/yr 1.000E+OO 3.000E+OO l.OOOE+Ol 3.000E+Ol 1.000E+02
1. 219E+Ol 1.278E+Ol
1. 507E'1-0l
2. 4 llE+Ol 1.250E+02 4.510E+Ol
4. 511E+Ol 4.513E+Ol 4.521E+Ol 4.548E+Ol 3.293E+OO 3.664E+OO
  • 5.319E+OO 1.544E+Ol 9.664E+Ol limit*

Page 20 of 25 1.000E+02 3.000E+02 1.000E+03

1. 4 95E-03 1. 4 70E-03 1.384E-03
9. 668E-ll 1. 983E-10 1.208E-09 4.228E-12 2. 917E-11 1. 679E-10 8.870E-13 8.918E-12 6.504E-11
1. 4 95E-03 1. 4 70E-03 1.384E-03 7.559E-03 7. 430E-03 6.995E-03
4. 888E-l.O 1.003E-09 6.108E-09 2.138E-11 1. 4 75E-10 8.486E-10
4. 371E-12 4. 394E-ll 3.214E-10 7.559E-03 7.430E-03 6.995E-03 2.092E-05 2.056E-05 1.936E-05
1. 353E-12 2.775E-12 1. 690E-ll 5.916E-14 4. 082E-13 2.349E-12
1. 212E-14 1.218E-13 8.910E-13 2.092E-05 2.056E-05 1.936E-05 4.536E-07 4.458E-07 4.197E-07
2. 93.3E-14 6. 017E-14 3.665E-13 1.283E-15 8.850E-15 5.092E~14 2.356E-16 2.369E-15 1. 747E-14 4.536E-07 4.458E-07 4.197E-07 l.255E-09 1. 234E-09 1.162E-09
8. llBE-17 1. 665E-16 1. 014E-15 3.550E-18 2.449E-17 1. 409E-16 6.536E-19 6.571E-18 4.844E-17 1.255E-09 1. 234E-09 1~l62E-09 2.587E-01 6.109E-06 3. 911E-22 3.000E+02 1.000E+03
1. 377E+04
1. 933E+ll 4.628E+Ol

.4 *. 915E+Ol 4.092E+06

  • 1. 366E+14

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T'> Limi.t = 180 days 07/22/2016 11:17 Page 21 summary RESRAD Default Parameters File C: \\RESRAD_FAMILY\\RESRAD\\ 7. 0\\USERFILES\\AREA 3.1 PU.RAD Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin time of minimum single radionuclide soil guideline and at tmax time of maximum total dose = O.OOOE+OO years ONuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)

(i)

(pCi/g)

(years)

(pCi/g)

(pCi/g)

Cs-137 l.016E+OO Pu-239 l.091E+OO Sr-90 5.620E-01 O.OOOE+OO 0.000E+OO O.OOOE+OO 2.099E+OO l.191E+Ol 2.099E+00 l.191E+Ol 5.544E-01 4.509E+Ql 5.544E-01 4.509E+Ol 8.00SE+OO 3.123E+OO 8.00SE+OO 3.123E+OO Page 21of25

Apperidix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit ~ 180 days.

07/22/2016 11: 17 Page 22 Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated ONuclide Parent THF(i)

DOSE(j,t), rnrern/yr (j)

(i) t~ O.OOOE+OO 1.000E+OO 3.000E+OO 1.000E+Ol 3.000E+Ol 1.000E+02 3.000E+02 1.000E+03 Cs-137 Cs-137

1. OOOE+OO 2.133E+00 2.083E+00 1.988E+OO 1. 686E+OO 1. 054E+OO 2.032E-01 1. 844E-03 1. 314E-10 OPu-239 Pu-239
5. 901E-04 3.569E-04 3.569E-04 3.568E-04 3.566E-04 3.560E-04 3.538E-04 3.478E-04 3.274E-04 Pu-239 Pu-239 1.633E-06 9.878E-07 9.877E-07 9.875E-07 9.869E-07 9.852E-07 9.793E-07 9.626E-07 9.062E-07 Pu-239 EDOSE(j) 3.579E-04 3.579E-04 3.578E-04 3.576E-04 3.570E-04 3.548E-04 3.488E-04 3.283E-04 OU-235 Pu-239 5.901E-04 l.390E-13 4.187E-13 9.749E-13 2.884E-12 8.029E-12 2.288E-11 4. 694E-11 2.859E-10 U-235 Pu-239 1.633E-06 3.846E-16 1.159E-15 2.698E-15 7.982E-15 2.222E-14 6.333E-14 1. 299E-13 7.913E-13 U-235 Pu-239 8.257E-06 1.944E-15 5.859E-15 1. 364E-14 4.035E-l4 1.123E-13 3. 202E-13 6.568E-13 4.000E-12 U-235 Pu-239 2.285E-08 5.381E-18 1. 622E-17 3.775E-17 1.117E-16 3.109E-16 8. 861E-16 1. 818E-15 1.107E-14 U-235 Pu"-239 4.954E-10 1.167E-19 3.516E-19 8.185E-19 2.421E-18 6.741E-18 1.921E-17 3.941E-17 2.400E-16 U-235 Pu-239
1. 371E-12 3.229E-22 9.730E-22 2.265E-21 6.701E-21 1. 866E-20 5.317E-20 1. 091E-19 6.643E-19 U-235 Pu-239 9.829E-01 2.314E-10 6. 97*5E-10 1. 624E-09 4. 804E-09 *1. 337E-08 3. 811E-OB 7.819E-08 4. 762E-07 U-235 Pu-239
2. 720E-03 6.406E-13 l.930E-12 4. 494E-12 1. 329E-11 3. 701E-11 1. 055E-10 2.164E-10 1. 318E-09 U-235 Pu-2'39 1.375E-02 3.238E-12 9.759E-12 2. 272E-11 6. 721E-11 1.871E-10 5.333E-10 1. 094E-09 6.663E-09 U-235 Pu-239 3.806E-05 8.963E-15 2.701E-14 6.289E-14 1. 860E-13 5.179E-13 1. 476E-12 3.028E-12 1. 844E-ll U-235 Pu-239 8.252E-07
1. 943E-16 5.856E-16 1.363E-15 4.033E-15 1.123E-14 3.200E-14 6.564E-14 3.998E-13 U-235 Pu-239 2.284E-09 5.378E-19 1. 621E-18 3.773E-18 1.116E-17 3.108E-17 8.856E-17 1. 817E-16 1.107E-15 U-235 EDOSE(j) 2.355E-10 7.096E-10 1.652E-09 4.887E-09 1. 361E-08 3.878E-08 7.955E-08 4. 8.45E-07 OPa-231 Pu-239
5. 901E-.04 3.454Ec-17 2.553E-16 1. 378E-15 1. 236E-14 1. 016E-13 1.00lE-12 6.904E-12 3. 972E-11 Pa-231 Pu-239
1. 633E-06 9.559E-20 7.065E-19 3.814E-18 3. 420E-17 2.812E-16 2.769E-15 1. 911E-14 1. 099E-13 Pa-231 Pu-239 8.257E-06 4.833E-19 3. 572E-18 1. 928E-17 1. 729E-16 1. 422E-15 1. 400E-14 9. 661E-14 5.558E-13 Pa-231 Pu-239 2.285E-08 1.:i'37E-21 9.886E-21 5.337E-20 4.785E-19 3.935E-18 3.875E-17 2.674E-16 1. 538E-15 Pa-231 Pu-239 4.954E-10 2.900E-23 2.143E-22 1.157E-21 1.037E-20 8.532E-20 8.401E.-19 5.797E-18 3.335E-17 Pa-231 Pu-239
1. 371E-12 8.025E-26 5.932E-25 3.202E-24 2.871E-23 2.361E-22 2.325E-21 1.604E-20 9.231E-20 Pa-231 Pu-239 9.829E-01 5.753E-14 4.252E-13 2.295E-12 2.058E-11 1.693E-10 1.667E-09 1.150E-08 6.617E-08 Pa-231 Pu-239 2.720E-03
1. 592E-16 1. l 77E-15 6.353E-15 5. 696E-14 4.685E-13 4. 613E-12 3.183E-11 1. 831E-10 Pa-231 Pu-239 l.375E-02 8.050E-16 5.950E-l5 3.212E-14 2. 880E-13 2.368E-12 2.332E-11 1. 609E-10 9.258E-10 Pa-231 Pu-239 3.806E-05 2.228E-18 1.647E-17 8.889E-17 7.971E-16 6.555E-15 6.455E-14 4.454E-13. 2.562E-12 Pa-231 Pu-239 8.252E-07 4.830E-20 3.. 570E-19 1. 927E-18 1. 728E-17 1. 421E-16 1. 399E-15 9.656E-15 5.555E-14 Pa-231 Pu-239 2.284E-09 l.337E-22 9.881E-22 5.334E-21 4.783E-20 3.933E-19 3.873E-18 2. 672E-l 7 1. 538E-16 Pa-231 EDOSE(j) 5.853E-14 4.326E-13 2.335E-12 2. 094E-11 1. 722E-10 1. 696E-09 1. l 70E-08 6.732E-08 OAc-227 Pu-239 5.901E-04
1. 520E-19 1. 958E-18 2.053E-17 4.841E-16 9.814E-15 2. lllE-13 2.llSE-12 1. 543E-11 Ac-227 Pu-239 9.829E-01 2.531E-16 3. 261E-15 3. 420E-14 8.063E-13 1. 635E-ll 3.517E-10 3.527E-09 2.570E-08 Ac-227 EDOSE(j) 2.533E-16 3.263E-15 3.422E-14 8. 068E-13 1. 636E-11 3.. 519E-10 3.529E-09 2.571E-08 OAc-227 Pu-239 l.633E-06 2.751E-22 4.322E-21 5.089E-20 1. 288E-18 2.676E-17 5.810E-16 5.841E-15 4.260E-14 Ac-227 Pu-239 8.257E-06 1.352E-21 2 *. 127E-20 2.506E-19 6.345E-18 l.319E-16 2.863E-15 2.878E-14 2.105E-13 Ac-227 Pu-239
2. 720E-03 4.582E-19 7.199E-18 8.477E-17 2.145E-15 4.458E-14 9.677E-13 9. 729E-12 7. 095E-11 Ac-227 EDOSE(j) 4.598E-19 7.225E-18 8.508E-17 2.153E-15 4.474E-14 9.712E-13 9.764E-12 7.121E-11 OPu-239 Pu-239 8.257E-06 4.994E-06 4.994E-06 4.993E-06 4.990E-06 4.981E-06 4.951E-06 4.866E-06 4.582E-06 Pu-239 Pu-239 2.285E-08 l.382E-08 1.382E-08 1.382E-08 1. 381E-08 1. 379E-08 1.370E-08 1. 34 7E-08 1. 268E-08 Pu-239 EDOSE(j) 5.00SE-06 5.007E-06 5.007E-06 5.003E-06 4.995E-06 4. 965E-06 4.880E-06 4.594E-06 OAc-227 Pu-239 2.285E-08 3.749E-24 5.899E-23 6.950E-22 1. 759E-20 3.656E-19 7.938E-18 7. 980E-17 5.836E-16 Ac-227 Pu-239 4.954E-10 7.238E-26 1.143E-24 l.349E-23 3.419E-22 7.109E-21 l.543E-19 1. 552E-18 1.144E-17 Page 22 of 25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RES RAD, Version 7.0 T" Limit = 180 days 07/22/2016 11: 17 Page 23 summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Individual Nuclide Dose Surmned Over All Pathways Parent Nuclide and Branch Fraction Indicated ONuclide Parent THF(i)

DOSE(j,t), mrem/yr

( j)

(i) t= 0.000E+OO 1. OOOE+OO 3.000E+OO 1. OOOE+Ol 3.000E+Ol l.OOOE+02 3.000E+02 1. OOOE+03 Ac-227 Pu-239 3.806E-05 6.245E-21 9.825E-20 l.158E-18 2. 930E-17 6.090E-16 1. 322E-14 1:329E-13 9.721E-13 Ac-227 l:DOSE(j) 6.249E-21 9.831E-20 l.158E-18 2.932E-17 6.094E-16 l.323E-14 1. 330E-13 9.727E-13 OPu-239 Pu-239 4.954E-10 2.997E-10 2.996E-10 2. 996E-10 2.994E-10 2.989E-10 2.971E-10 2.920E-10 2.749E-10 Pu-239 Pu-239

1. 371E-12 8.293E-13 8.293E-13 8. 291E-13 8.286E-13 8. 272E-13 8. 222E-13 8. 082E-13 7.608E-13 Pu-239 l:DOSE(j) 3.00SE-10 3.005E-10 3.004E-10 3.002E-10 2.997E-10 2.979E-10 2.928E-10 2.757E-10 OAc-227 Pu-239
1. 371E-12 2.00SE-28 3.171E-27 3.743E-26 9.484E-25 1. 972E-23 4.281E-22 4.304E-21 3.173E-20 Ac-227 Pu-239 2.284E-09 3.344E-25 5.282E-24 6.234E-23 1.SSOE-21 3.284E-20 7.130E-19 7.169E-18 5.285E-17 Ac-227 l:DOSE(j) 3.346E-25 5.285E-24 6.238E-23 l.581E-21 3.286E-20 7.135E-19 7.173E-18 5.288E-17 OPu-239 Pu-239 9.829E-01 5.945E-01 5.944E-01 5.943E-01 5.940E-01 5.930E-01 5.894E-01 5.793E-01 5.454E-01 Pu-239 Pu-239
2. 720E-03 l.645E-03 1.645E-03 l.645E-03 1. 644E-03 1.641E-03 1. 631E-03 1.603E-0~ l.509E-03 Pu-239 l:DOSE(j) 5.961E-01 5. 961E-01 5*. 960E-01 5.956E-01 5.946E-01 5.910E-01 5.809E-01 5.469E-01 OPu-239 Pu-239 l.375E-02 8.318E-03 8.318E-03 8. 316E--03 8. 311E-03 8.297E-03 8.247E-03 8.106E-03 7.631E-03 Pu-239 Pu-239 3.806E-05 2.302E-05 2.302E-05 2.302E-05 2.300E-05 2. 2 96E-05 2.282E-05 2.243E-05 2.112E-05 Pu-239 l:DOSE(j) 8.341E-03 8.341E-03 8.339E-03 8.334E-03 8.320E-03 8.270E-03 8.128E-03 7.652E-03 OAc-227 Pu-239 l.375E-02 2.252E-18 3. 543E-17 4.175E-16 1. 057E-14 2.196E-13 4.768E-12 4.794E-ll 3.507E-10 OPu-239 Pu-239 8.252E-07 4.991E-07 4. 991E-07 4.990E-07 4.987E-07 4.978E-07 4.948E-07 4.864E-07 4.579E-07 Pu-239 Pu-239 2.284E-09
1. 381E-09 l.381E-09 1. 381E-09 1. 380E-09 l.378E-09 1. 370E-09 1. 346E-09 1. 267E-09 Pu-239 l:DOSE(j) 5.005E-07 5.00SE-07 5.004E-07 5.00lE-07 4. 992E-07 4. 962E-07 4.877E-07 4.592E-07 OAc-227 Pu-239 8.252E-07
1. 206E-22 l.904E-21 2.248E-20 5. 696E-19 l.184E-17 2.571E-16 2.585E-15 1. 906E-14 OSr-90 Sr-90
1. OOOE+OO 4.499E+OO 4.266E+OO 3.835E+OO 2.641E+00 9.103E-01 1. 454E-01 3.433E-06 2.198E-22

==----

THF(i) is the thread fraction of the parent nuclide.

Page 23 of 25

Appendix H38: RESRAD 7.0 Output for Area 3.1 Pu-239 RESRAD, Version 7.0 T~ Limit = 180 days 07/22/2016 11: i7 Page 24 Summary RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated ONuclide Parent THF(i) s (j,t)' pCi/g I j l (i) t= O.OOOE+OO 1.000E+OO 3.000E+OO 1.000E+Ol 3.000E+Ol 1.000E+02 3.000E+02 1. 00.0E+03 Cs-137 Cs-137 1.000E+OO

1. 016E+OO 9.924E-01 9.468E-Ol 8.031E-01 5.019E-01 9.680E-02 8.786E-04 6. 259E-11 OPu-239 Pu-239 5.901E-04 6.438E-04 6.437E-04 6. 436E-04 6. 432E-04 6.421E-04 6.383E-04 6.273E-04 *5. 906E-04 Pu-239 Pu-239 l.633E-06
1. 782E-06 l.782E-06 1. 781E-06 1. 780E-06 1. 777E-06 1. 766E-06 1. 736E-06 1.635E-06 Pu-239 ES (j):
6. 456E-04 6. 4 55E-04 6.454E-04 6.450E-04 6.439E-04 6.400E-04 6.291E-04 5.922E-04 0\\)-235 Pu-239 5.901E-04 O.OOOE+OO 6.325E-13 l.889E-12 6.203E-12 1. 783E-ll 5.139E-ll 1. 058E-10 l.374E-10 U-235 Pu-239 1.633E-06 0.000E+OO l.750E-15 5.229E-15 1.717E-14 4.934E-14 1. 422E-13 2.927E-13 3. 802E-13 U-235 Pu-239 8.257E-06 O.OOOE+OO 8.850E-15 2.643E-14 8.679E-14 2.495E-13 7.191E-13 1. 480E-12 1.922E-12 U-235 Pu-239 2.285E-08 0.000E+OO 2. 449E-17 7. 316E-17 2.402E-16 6.904E-16 1. 990E-15 4.095E-15 5.319E-15 U-235 Pu-239 4.954E-10 O.OOOE+OO 5.310E-19 l.586E-18 5.208E-18 1.497E-17 4.315E-17 8.879E-17 1.153E-16 U-235 Pu-239
1. 371E-12 O.OOOE+OO 1.470E-21 4.390E-21 1. 4 4 lE-20 4.143E-20 1.194E-19 2.457E-19 3.192E-19 U-235 Pu-239 9.829E-01 0.000E+OO 1. 054E-09 3.147E-09 1.033E-08 2.970E-08 8.560E-08 1. 762E-07 2.288E-07 U-235 Pu-239
2. 720E-03 O.OOOE+OO 2.916E-12 8.709E-12 2.860E-ll 8. 219E-ll 2.369E-10 4.875E-10 6.332E-10 U-235 Pu-239 1.375E-02 O.OOOE+OO 1. 474E-11 4. 403E-11 1. 446E-10 4.155E-10 1.198E-09 2. 4 65E-09 3.201E-09 U-235 Pu-239 3.806E-05 O.OOOE+OO 4.080E-14 1. 219E-13 4.00lE-13 1.150E-12 3.315E-12 6.822E-12 8.860E-12 U-235 Pu-239 8.252E-07 O.OOOE+OO 8.845E-16 2.642E-15 8.. 675E-15 2.493E-14 7.187E-14 1. 4 79E-13 1. 921E-13 U-235
    • Pu-239 2.284E-09 O.OOOE+OO 2.448E-18 7.312E-18 2.401E-17 6.901E-17 1. 989E-16 4.093E-16 5.317E-16 U-235 ES (j) :

0.000E+OO l.072E-09 3.202E-09 l.051E-08 3.021E-08 8.709E-08 1. 792E-07 2.328E-07 OPa-231 Pu-239 5.901E-04 O.OOOE+OO 6.696E-18 6. OOBE-17 6.608E-16 5.776E-15 5.812E-14 4.035E-13 2.247E-12 Pa-231 Pu-239 1.633E-06 O.OOOE+OO 1. 853E-20 1.663E-19 l.829E-18 1. 599E-17 1. 608E-16 1.117E-15 6.219E-15 Pa-231 Pu-239 8.257E-06 0.000E+OO 9.369E-20 8.407E-19 9.246E-18 8.082E-17 8.132E-16 5.645E-15 3.144E-14 Pa-231 Pu-239 2.285E-08 O.OOOE+OO 2.593E-22 2.327E-21 2.559E-20 2.237E-19 2.251E-18 l.562E-17 8.702E-17 Pa-231 Pu-239

4. 954E-10 O.OOOE+OO 5.622E-24 5.045E-23 5.548E-22 4.849E-21 4.879E-20 3.387E-19 l.887E-18 Pa-231 Pu-239
1. 371E-12 O.OOOE+OO 1. 556E-26 1. 396E-25 1.535E-24 1. 342E-23 1.350E-22 9.375E-22 5.222E-21

'Pa-231 Pu-239 9.829E-01 O.OOOE+OO 1.115E-14 1. OOlE-13 1.lOlE-12 9.621E-12 9. 680E-ll 6.720E-10 3.743E-09 Pa-231 Pu-239 2.720E-03 O.OOOE+OO 3.087E-17 2.770E-16 3.046E-15 2.663E-14 2.679E-13 1. 860E-12 1. 036E-ll Pa-231 Pu-239

1. 375E-02 0.000E+OO 1. 561E-16 1. 400E-15 l.540E-14 1.'346E-13 1.354E-12 9.403E-12 5. 237E-ll Pa-231 Pu-239 3.806E-05 O.OOOE+OO 4. 31.9E-19. 3.876E-18 4.262E-17 3.726E-16 3.749E-15 2.603E-14 1. 449E-13 Pa-231 Pu-239 8.252E-07 O.OOOE+OO 9.364E-21 8.403E-20 9.241E-19 8.077E-18 8.127E-17 5.642E-16 3.142E-15 Pa-231 Pu-239 2.284E-09 O.OOOE+QO 2.592E-23 2.326E-22 2.557E-21 2.236E-20 2.249E-19 1. 562E-18 8.697E-18 Pa-231 ES (j):

O.OOOE+OO 1.135E-14 1. 018E-13 1.120E-12 9.788E-12 9.849E-11 6.837E-10 3.808E-09 OAc-227 Pu-239 5.901E-04 O.OOOE+OO 7.052E-20 1..870E-18 6. 509E-17 1. 485E-15 3.330E-14 3.375E-13 2.157E-12 Ac-227 Pu-239 9.829E-01 0.000E+OO.1.175E-16 3.115E-15 1. 084E-13 2.474E-12 5. 546E-11 5.622E-10 3.592E-09 Ac-227 ES (j):

O.OOOE+OO 1.175E-16 3. ll 7E-15 1.085E-13 2.475E-12 5.549E-ll 5.625E-10 3.594E-09 OAc-227 Pu-239 1.633E-06 O.OOOE+OO l.952E-22 5.175E-21 1.802E-19 4. llOE-18 9.215E-17 9.341E-16 5.969E-15 Ac-227 Pu-239 8.257E-06 O.OOOE+OO 9. 867E-22 2.617E-20 9.108E-19 2.078E-17 4.659E-16 4. 723E-15 3.018E-14 Ac-227 Pu-239

2. 720E-03 O.OOOE+OO 3.251E-19 8.621E-18 3.00lE-16 6.846E-15 1. 535E-13 1.556E-12 9.942E-12 Ac-227 ES (j):

0.. OOOE+OO 3.263E-19 8.652E-18 3.012E-16 6.871E-15 1. 540E-13 1. 562E-12 9.978E-12 OPu-239 Pu-239 8.257E-06 9.008E-06 9.007E-06 9.006E-06 9.000E-06*8.985E-06 8.931E-06 8; 778E-06 8.264E-06 Pu-239 Pu-239 2.285E-08 2.493E-08 2.493E-08 2.492E-08 2.491E-08 2.487E-08 2. 4 72E-08 2.429E-08 2.287E-08 Pu-239 ES (j):

9.033E-06 9.032E-06 9.031E-06 9.025E-06 9.0lOE-06 8.955E-06 8.802E-06 8.287E-06 OAc-227 Pu-239 2.285E-08 O.OOOE+OO 2.731E-24 7.242E-23 2.521E-21 5.751E-20 L 289E-18 l.307E-17 8.352E-17 Ac-227 Pu-239 4.954E-10 O.OOOE+OO 5.921E-26 1.570E-24 5.465E-23 1.247E-21 2.795E-20 2.834E-19 1. SllE-18 Page 24 of 25

Appendix H38: RESRAD 7.0 Output for Area 3:1 Pu-239 RESRAD, Version 7.0 Tu Limit= 180 days 07/22/2016 11:17 Page

  • 25 summary,: RESRAD Default Parameters File C:\\RESRAD_FAMILY\\RESRAD\\7.0\\USERFILES\\AREA 3.1 PU.RAD Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated ONuclide Parent THF(i) s (j' t)' pCi/g (j I Iii t= 0.000E+OO 1.000E+OO 3.000E+OO 1.000E+Ol 3.000E+Ol 1.000E+02 3.000E+02 1.000E+03 Ac-227 Pu-239 3.806E-05
0. OOOE.+00 4.549E-21 1. 206E-19 4.199E-18 9.580E-17 2.148E-15 2.177E-14 1.391E-13 Ac-227 ES (j I:

O.OOOE+OO 4.552E-21 1. 207E-19 4.201E-18 9.586E-17 2.149E-15 2.178E-14 1. 392E-13 OPu-239 P.u-239 4.954E-10 5.405E-10 5.405E-10 5.404E-10 5.400E-10 5.391E-10 5.359E-10 5. 267E-10 4.959E-10 Pu-239 Pu-239

1. 371E-12
1. 496E-12 1..4 96E-12 1.496E-12 1. 495E-12 1. 492E-12 1. 483E-12 1.458E-12 1. 372E-12 Pu-239 ES (j I:
5. 420E-10 5. 420E-10 5.419E-10 5.415E-10 5.406E-10 5.374E-10 5.282E-10 4.972E-10 OAc-227 Pu.:.239
1. 371E-12 O.OOOE+OO 1. 63 9E-28 4.345E-27 l.513E-25 3.451E-24 7.737E-23 7.843E-22 5. OllE-21 Ac-227 Pu-239 2.284E-09 0.000E+OO 2.729E-25 7.238E-24 2.519E-22 5.748E-21 1.289E-19 1.306E-18 8.347E-18 Ac-227 ES (j I:

0.000E+OO 2.731E-25 7.242E-24 2.521E-22 5.752E-21 1.289E-19 l.307E-18 8.352E-18 OPu-239 Pu-239 9.829E-01 1.072E+OO 1.072E+OO 1. 072E+OO 1.071E+OO l.070E+00 1.063E+OO 1.045E+OO 9. 838E-01 Pu-239 Pu-239 2.720E-03

2. 968E-03 2.968E-03 2.967E-03 2. 965E-03 2.960E-03 2.942E-03 2.892E-03 2.723E-03 Pu-239 ES (j):
1. 075E+OO 1. 075E+OO 1. 075E+OO 1. 074E+OO 1.073E+OO 1.066E+OO 1. 04 SE+OO 9.865E-01*

OPu-239 Pu-239

1. 375E-02 1.SOOE-02 1.SOOE-02 1. 500E-02 1. 4 99E-02 1. 4 97E-02 1*. 4 88E-02 1. 4 62E-02 1.377E-02 Pu-239 Pu-239 3.806E-05 4.153E-05 4.152E-05 4.152E.,-05 4.149E-05 4.142E-05 4.117E-05 4.047E-05 3.810E-05 Pu-239 ES (j I:

1.505E-02 1. 504E-02 1. 504E-02 1. 503E-02 l.501E-02 1. 4 92E-02 1. 4 66E-02 1.380E-02 OAc-227 Pu-239 1.375E-02 O.OOOE+OO 1. 644E-18 4.358E-17 1. 517E-15 3.461E-14 7.760E-13 7. 8 66E-.12 5. 026E-11 OPu-239 Pu-239 8.252E-07 9.003E-07 9.002E-07 9.00lE-07 8.995E-07 8.980E-07 8.926E-07 8. 773E-07 8. 260E-07 Pu-239 Pu-239 2.284E-09 2.492E-09 2.492E-09 2.491E-09 2.490E-09 2.485E-09 2.470E-09 2.428E-09 2.286E-09 Pu-239 ES (j I:

9.028E-07 9:027E-07 9.026E-07 9.020E-07 9.005E-07 8.951E-07 8.798E-07 8.282E-07 OAc-227* Pu-239 8.252E-07 O.OOOE+OO 9.862E-23 2.615E-21 9.103E-20 2.077E-18 4.656E-17 4.720E-16 3.016E-15 OSr-90 Sr-90 l.OOOE+OO 5.620E-01 5.328E-01 4.790E-01 3.299E-01 1.137E-01 2.731E-03 6. 4 SOE-08 4.129E-24

==

THF(i) is the thread fraction of the parent nuclide.

ORESCALC.EXE execution time =

7.70 seconds Page 25 of 25