Analytical Results by Area 1 2 3

)...

',i

f Background ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty GAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA1.1.1 SAMPLE 1/4/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.173 14952-40-0 PCl/G UI 0.339 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.15 0.247 14952-40-0 PCl/G u 0.450 1.00 22.9 BGA1.1.1 SAMPLE 1/11/2016 388119 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 23.8 4.96 12587-46-1 PCl/G 3.49 4.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Americium-241 R

DOE EML HASL-300, Am-05-RC Modified

-0.00264 0.0397 14596-10-2 PCl/G u 0.0927 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0231 0.0671 14234-35-6 PCl/G u 0.125 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00342 0.0904 14234-35-6 PCl/G u 0.170 1.00 22.9 BGA1.1.1 SAMPLE 1/11/2016 388119 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 24.9 3.46 12587-47-2 PCl/G 3.81 10.0 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.860 0.631 14913-49-6 PCl/G 0.659 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.782 14913-49-6 PCl/G UI 1.46 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.784 0.134 14733-03-0 PCl/G 0.0993 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.956 0.166 14733-03-0 PCl/G 0.129 1.00 22.9 BGA1.1.1 SAMPLE 1/19/2016 388119 Carbon-14 R

EPA EERF C-01 Modified

-0.335 0.796 14762-75-5 PCl/G u 1.37 2.00 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.167 0.0417 10045-97-3 PCl/G 0.0456 0.100 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.120 0.0534 10045-97-3 PCl/G 0.0683 0.100 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0105 0.0323 10198-40-0 PCl/G u 0.0489 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.012 0.040 10198-40-0 PCl/G u 0.0814 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Curium-242 R

DOE EML HASL-300, Am-05-RC Modified 0.00 0.0289 OER-100-93 PCl/G 0.043 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Curium-243/244 R

DOE EML HASL-300, Am-05-RC Modified 0.0298 0.0526 PCl/G 0.0797 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Curium-245/246 R

DOE EML HASL-300, Am-05-RC Modified 0.0569 0.067 PCl/G 0.0725 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0356 0.111 15585-10-1 PCl/G u 0.185 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00899 0.117 15585-10-1 PCl/G u 0.227 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016, 388119 lodine-129 R

DOE EML HASL-300,1-01 Modified 0.00 0.921 15046-84-1 PCl/G UI 0.525 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.40 0.0952 15092-94-1 PCl/G 0.0765 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.28 0.141 15092-94-1 PCl/G 0.120 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.10 0.128 15067-28-4 PCl/G 0.235 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.36 0.208 15067-28-4 PCl/G 0.368 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Neptunium-237 R

ASTM C 1476-00 Modified 0.0614 0.230 13994-20-2 PCl/G u 0.388 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Plutonium-238 R

DOE EML HASL-300, Pu-11-RC Modified 0.0173 0.0668 13981-16-3 PCl/G u 0.129 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Plutonium-239/240 R

DOE EML HASL-300, Pu-11-RC Modified 0.0288 0.0655 OER-100-70 PCl/G u 0.112 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/14/2016 388119 Plutonium-241 R

DOE EML HASL-300, Pu-11-RC Modified

-5.07 6.92 14119-32-5 PCl/G u 12.2 15.0 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.9 1.08 13966-00-2 PCl/G 0.437 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.2 1.51 13966-00-2 PCl/G 0.743 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.532 14331-85-2 PCl/G UI 0.596 1.00 22.9 BGA1.1.1. SAMPLE 1/20/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00

.0.695 14331-85-2 PCl/G UI 0.927 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.784 0.134 13982-63-3 PCl/G 0.0993 1.00 22.9 BGA1.U SAMPLE 1/20/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.956 0.166 13982-63-3 PCl/G 0.129 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.00 0.218 15262-20-1 PCl/G 0.218 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.23 0.287 15262-20-1 PCl/G 0.261 1.00 22.9 BGA1.1.1 SAMPLE 1/7/2016 388119 Strontium-90 R

EPA 905.0 Modified/DOE RP501 Rev. 1 Modified

-0.842 0.757 10098-97-2 PCl/G u 1.66 2.00 1.00 22.9 BGA1.1.1 SAMPLE 1/19/2016 388119 Technetium-99 R

DOE EML HASL-300, Tc-02-RC Modified

-0.214 1.64 14133-76-7 PCl/G u 2.88 5.00 1.00 22.9 BGA1.1.1 SAMPLE 1/4/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.392 0.0606 14913-50-9 PCl/G 0.0466 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.374 0.0803 14913-50-9 PCl/G 0.0698 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Thorium-228 R

DOE EML HASL-300, Th-01-RC Modified 1.01 0.607 14274-82-9 PCl/G 0.483 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016

.388119 Thorium-229 R

DOE EML HASL-300, Th-01-RC Modified 0.143 0.280 15594-54-4 PCl/G 0.389 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Thorium-230 R

DOE EML HASL-300, Th-01-RC Modified 1.36 0.675 14269-63-7 PCl/G o*.388 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Thorium-232 R

DOE EML HASL-300, Th-01-RC Modified 0.887 0.549 7440-29-1 PCl/G 0.242 1.00 1.00 22.9 BGA1.1.1 SAMPLE.

1/4/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0645 PCl/G UI 0.0681 1.00 22.9 BGA1.1.1 SAMPLE 1/20/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.116 PCl/G UI 0.174 1.00 22.9 BGA1.1.1 SAMPLE 1/11/2016 388119 Tritium R

EPA 906.0 Modified 0.104 2.36 10028-17-8 PCl/G u 4.09 6.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Uranium-232 R

DOE EML HASL-300, U-02-RC Modified

-0.00902 0.0623 14158-29-3 PCl/G u 0.152 1.00 1.00 22.9

Backgroun ackgrour:td Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty* CAS Units Lab Qu MDL CRDL Dilution % Moist!

BGA1.1.1 SAMPLE 1/12/2016 388119 Uranium-233/234 R

DOE EML HASL-300, U-02-RC Modified 0.855 0.246 13968-55-3/139 PCl/G 0.123 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Uranium-235/236 R

DOE EML HASL-300, U-02-RC Modified 0.136 0.104 15117-96-1/139 PCl/G 0.0842 1.00 1.00 22.9 BGA1.1.1 SAMPLE 1/12/2016 388119 Uranium-238 R

DOE EML HASL-300, U-02-RC Modified 0.863 0.246 7440-61-1 PCl/G 0.107 1.00 1.00 22.9 BGA1.1.1 MS 1/20/2016 388119 Carbon-14 R

EPA EERF C-01 Modified 97.6 1.79 14762-75-5 1.40 2.00 1.00 22.9 BGA1.1.1 MS 1/20/2016 388119 lodine-129 R

DOE EML HASL-300,1-01 Modified 79.7 3.30 15046-84-1 1.57 1.00 1.00 22.9 BGA1.1.1 MS 1/12/2016 388119 Tritium R

EPA 906.0 Modified 103 9.58 10028-17-8 9.54 6.00 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.191 0.269 14952-40-0 PCl/G u 0.461 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.129 0.299 14952-40-0 PCl/G u 0.556 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0895 14234-35-6 PCl/G UI 0.178 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0387 0.0983 14234-35-6 PCl/G u 0.179 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.878 14913-49-6 PCl/G UI 1.33 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00*

0.807 14913-49-6 PCl/G UI 1.48 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.905 0.177 14733-03-0 PCl/G 0.127 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.15 0.203 14733-03-0 PCl/G 0.141 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Carbon-14 R

EPA EERF C-01 Modified 0.0673 0.802 14762-75-5 PCl/G u 1.37 2.00 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0764 0.0702 10045-97-3 PCl/G 0.065 0.100 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.191 0.0737 10045-97-3 PCl/G 0.0693 0.100 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0167 0.0338 10198-40-0 PCl/G u 0.0729 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0268 0.0429 10198-40-0 PCl/G u 0.0758 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0389 0.101 15585-10-1 PCl/G u 0.220 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.127 0.125 15585-10-1 PCl/G u 0.201 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 lodine-129 R

  • DOE EML HASL-300,1-01 Modified 0.042 0.239 15046-84-1 PCl/G u 0.564 1.00 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Lead-210 R

DOE HASL 300, 4.5.2.3/Ga-01-R 3.06 5.61 14255-04-0 PCl/G u 10.4 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.28 0.131 15092-94-1 PCl/G 0.108 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.34 0.134 15092-94-1 PCl/G 0.114 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.979 0.166 15067-28-4 PCl/G 0.126 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.10 0.197 15067-28-4 PCl/G 0.136 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 15.4 1.26 13966-00-2 PCl/G 0.467 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.5 1.48 13966-00-2 PCl/G 0.588 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.483 14331-85-2 PCl/G UI 0.985 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.458 0.704 14331-85-2 PCl/G u 1.04 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.905 0.177 13982-63-3 PCl/G 0.127 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.15 0.203 13982-63-3 PCl/G 0.141 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.37 0.253 15262-20-1 PCl/G 0.226 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.05 0.365 15262-20-1 PCl/G 0.286 1.00 22.9 BGA1.1.1 DUP 1/19/2016 388092 Technetium-99 R

DOE EML HASL-300, Tc-02-RC Modified

-1.03 1.70 14133-76-7 PCl/G u 3.04 5.00 1.00 22.9 BGA1.1.1 DUP 1/19/2016 388119 Technetium-99 R

DOE EML HASL-300, Tc-02-RC Modified

-1.03 1.70 14133-76-7 PCl/G u 3.04 5.00 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.332 0.0625 14913-50-9 PCl/G 0.0625 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.445 0.0796 14913-50-9 PCl/G 0.0738 1.00 22.9 BGA1.1.1 DUP 1/5/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.117 PCl/G UI 0.155 1.00 22.9 BGA1.1.1 DUP 1/20/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.120 PCl/G UI 0.131 1.00 22.9 BGA1.1.1 DUP 1/12/2016 388119 Tritium R

EPA 906.0 Modified

-0.262 2.36 10028-17-8 PCl/G u 4.12 6.00 1.00 22.9 BGA1.1.2 SAMPLE 1/4/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0853 0.176 14952-40-0 PCl/G u 0.309 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.104 0.253 14952-40-0 PCl/G u 0.495 1.00 22.6 BGA1.1.2 SAMPLE 1/11/2016 388119 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 15.8 3.99 12587-46-1 PCl/G 3.93 4.00 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0408 0.059 14234-35-6 PCl/G u 0.112 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0805 0.0929 14234-35-6 PCl/G u 0.188 1.00 22.6 BGA1.1.2 SAMPLE 1/11/2016 388119 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 23.0 3.30 12587-47-2 PCl/G 3.77 10.0 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.25 0.490 14913-49-6 PCl/G 0.641 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.765 14913-49-6 PCl/G UI 1.39 1.00 22.6

Background ackground Sample.No. Type Analyzed SDG Parameter

    • Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist!

BGA1.1.2 SAMPLE 1/4/2016 388119 Bismuth-214

  • R DOE HASL 300, 4.5.2.3/Ga-01-R 0.769 0.117 14733-03-0 PCl/G 0.083 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Bism uth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.06 0.200 14733-03-0 PCl/G 0.136 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0378 10045-97-3 PCl/G UI 0.0434 0.100 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0435 10045-97-3 PCl/G UI 0.0915 0.100 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0108 0.0262 10198-40-0 PCl/G u 0.0462 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0278 0.0434 10198-40-0 PCl/G u 0.0918 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0256 0.0807 15585-10-1 PCl/G u 0.143 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.073 0.131 15585-10-1 PCl/G u 0.271 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.40 0.0923 15092-94-1 PCl/G 0.0697 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.39 0.136 15092-94-1 PCl/G 0.104 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.15 0.120 15067-28-4 PCl/G 0.089 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.36 0.175 15067-28-4 PCl/G

. 0.162 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.6 0.965 13966-00-2 PCl/G 0.415 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 13.4 1.45 13966-00-2 PCl/G 0.575 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.425 14331-85-2 PCl/G UI 0.589 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.614 14331-85-2 PCl/G UI 0.769 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.769 0.117 13982-63-3 PCl/G 0.083 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.06 0.200 13982-63-3 PCl/G 0.136 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.23 0.204 15262-20-1 PCl/G 0.164 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.25 0.390 15262-20-1 PCl/G 0.278 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.372 0.0487 14913-50-9 PCl/G 0.045 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.380 0.0818 14913-50-9 PCl/G 0.0811 1.00 22.6 BGA1.1.2 SAMPLE 1/4/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.093 PCl/G UI 0.0983 1.00 22.6 BGA1.1.2 SAMPLE 1/20/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.156 PCl/G UI 0.110 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0748 0.235 14952-40-0 PCl/G u 0.426 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.151 0.320 14952-40-0 PCl/G u 0.624 1.00 22.6 BGA1.1.3 SAMPLE 1/11/2016 388119 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 16.5 3.71 12587-46-1 PCl/G 3.41 4.00 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01~R 0.0429 0.0809 14234-35-6 PCl/G u 0.154 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0191 0.106 14234-35-6 PCl/G u 0.194 1.00 22.6 BGA1.1.3 SAMPLE 1/11/2016 388119 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 28.9 3.25 12587-47-2 PCl/G 3.42 10.0 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.84 0.712 14913-49-6 PCl/G 0.852 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.877 14913-49-6 PCl/G UI 1.42 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.844 0.140 14733-03-0 PCl/G 0.128 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.18 0.196 14733-03-0 PCl/G 0.129 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0159 0.0356 10045-97-3 PCl/G u 0.0661 0.100 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.017 0.0446 10045-97-3 PCl/G u 0.0808 0.100 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0384 10198-40-0 PCl/G UI 0.0636 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.023"4 0.0491 10198-40-0 PCl/G u 0.0913 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0175 0.0999 15585-10-1 PCl/G u 0.187 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0454 0.155 15585-10-1 PCl/G u 0.290 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.63 0.112 15092-94-1 PCl/G 0.0948 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.46 0.153 15092-94-1 PCl/G 0.128 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.15 0.155 15067-28-4 PCl/G 0.124 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.44 0.223 15067-28-4 PCl/G 0.400 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 13.6 1.19 13966-00-2 PCl/G 0.547 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.7 1.64 13966-00-2 PCl/G 0.638 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.701 14331-85-2 PCl/G UI 0.763 1.00 22.6.

BGA1.1.3 SAMPLE 1/20/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.659 14331-85-2 PCl/G UI 1.32 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.844 0.140 13982-63-3 PCl/G 0.128 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.18 0.196 13982-63-3 PCl/G 0.129 1.00 22.6

Backgroun ackground Sample No. Type.

Analyzed SDG Parameter Fraction Method Result Uncertainty GAS Units Lab*Qu MDL CRDL Dilution % Moist1 BGA1.1.3 SAMPLE 1/4/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.42 0.261 15262-20-1 PCl/G 0.237 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.36 0.404 15262-20-1 PCl/G 0.267 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.479 0.0749 14913-50-9.

PCl/G 0.0617 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.427 0.0988 14913-50-9 PCl/G 0.0815 1.00 22.6 BGA1.1.3 SAMPLE 1/4/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.109 PCl/G UI 0.141 1.00 22.6 BGA1.1.3 SAMPLE 1/20/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.154 PCl/G UI 0.181 1.00 22.6 BGA1.1.4 SAMPLE 1/4/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0553 0.191 14952-40-0.

PCl/G u 0.341 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0889 0.295 14952-40-0 PCl/G u 0.499 1.00 20.3 BGA1.1.4 SAMPLE 1/11/2016 388119 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 10.7 3.19 12587-46-1 PCl/G 3.95 4.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Americium-241 R

DOE EML HASL-300, Am-05-RC Modified 0.0135 0.0507 14596-10-2 PCl/G u 0.0854 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0116 0.0691 14234-35-6 PCl/G u 0.121 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Antimony-125 R

  • DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0245 0.103*

14234-35-6 PCl/G u 0.182 1.00 20.3 BGA1.1.4 SAMPLE 1/11/2016 388119 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 22.5 2.85 12587-47-2 PCl/G 3.21 10.0 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Bismuth-212

  • R DOE HASL 300, 4.5.2.3/Ga-01-R 1.04 0.545 14913-49-6 PCl/G 0.632 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.33 0.849

.14913-49-6 PCl/G 0.903 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.911 0.122 14733-03-0 PCl/G 0.0868 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.07 0.162 14733-03-0 PCl/G 0.132 1.00 20.3 BGA1.1.4 SAMPLE 1/19/2016 388119 Carbon-14 R

EPA EERF C-01 Modified

-0.0544 0.757 14762-75-5 PCl/G u 1.29 2.00 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.134 0.0444 10045-97-3 PCl/G 0.0488 0.100 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.175 0.0599 10045-97-3 PCl/G 0.0849 0.100 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00101 0.0251 10198-40-0 PCl/G u 0.0477 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Cobalt-60 R

DOE HASL 300,4.5.2.3/Ga-01-R 0.021 0.0391 10198-40-0 PCl/G u 0.0817 1.00.

20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Curium-242 R

DOE EML HASL-300, Am-05-RC Modified 0.00 0.0389 OER-100-93 PCl/G 0.0579 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Curium-243/244 R

DOE EML HASL-300, Am-05-RC Modified

-0.00844 0.0373 PCl/G u 0.0974 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Curium-245/246 R

DOE EML HASL-300, Am-05-RC Modified 0.0106 0.0589 PCl/G u 0.113 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0224 0.0896 15585-10-1 PCl/G u 0.171 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0778 0.132 15585-10-1 PCl/G u 0.268 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 lodine-129 R

DOE EML HASL-300,1-01 Modified 0:0342 0.644 15046-84-1 PCl/G u 1.17 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.32 0.0983 15092-94-1 PCl/G 0.0807 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.41 0.136 15092-94-1 PCl/G 0.106 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.17 0.128 15067-28-4 PCl/G 0.0984 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.29 0.194 15067-28-4 PCl/G 0.354 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Neptunium-237 R

ASTM C 1476-00 Modified 0.0027 0.200 13994-20-2 PCl/G u 0.445 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Plutonium-238 R

DOE EML HASL-300, Pu-11-RC Modified 0.0447 0.0611 13981-16-3 PCl/G 0.0833 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Plutonium-239/240 R

DOE EML HASL-300, Pu-11-RC Modified

-0.00927 0.0419 OER-100-70 PCl/G u 0.106 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/14/2016 388119 Plutonium-241 R

DOE EML HASL-300, Pu-11-RC Modified

-6.99 5.82 14119-32-5 PCl/G u 10.4 15.0 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.7 1.06 13966-00-2 PCl/G 0.356 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 13.1 1.43 13966-00-2 PCl/G 0.619 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.413 14331-85-2 PCl/G UI 0.732 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.655 14331-85-2 PCl/G UI 0.880 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.911 0.122 13982-63-3 PCl/G 0.0868 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.07 0.162 13982-63-3 PCl/G 0.132 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.41 0.222 15262-20-1 PCl/G 0.165 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.35 0.340 15262-20-1 PCl/G 0.293 1.00 20.3 BGA1.1.4 SAMPLE 1/7/2016 388119 Strontium-90 R

EPA 905.0 Modified/DOE RP501 Rev. 1 Modified

-0.228 0.549 10098-97-2 PCl/G u 1.14 2.00 1.00 20.3 BGA1.1.4 SAMPLE 1/19/2016 388119 Technetium-99 R

DOE EML HASL-300, Tc-02-RC Modified

-0.814 1.80 14133-76-7 PCl/G u 3.21 5.00 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.349 0.0564 14913-50-9 PCl/G 0.0425 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.348 0.0917 14913-50-9 PCl/G 0.0701 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Thorium-228 R

DOE EML HASL-300, Th-01-RC Modified 1.28 0.653 14274-82-9 PCl/G 0.517 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Thorium-229 R

DOE EML HASL-300, Th-01-RC Modified 0.227 0.336 15594-54-4 PCl/G 0.492 1.00 1.00 20.3

.,j

Background ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Maish BGA1.1.4 SAMPLE 1/12/2016 388119 Thorium-230 R

DOE EML HASL-300, Th-01-RC Modified 1.21 0.623 14269-63-7 PCl/G 0.455 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Thorium-232 R

DOE EML HASL-300, Th-01-RC Modified 0.929 0.548 7440-29-1 PCl/G 0.411 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/4/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0793 PCl/G UI 0.0803 1.00 20.3 BGA1.1.4 SAMPLE 1/20/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.135 PCl/G UI 0.124 1.00 20.3 BGA1.1.4 SAMPLE 1/11/2016 388119 Tritium R

EPA 906.0 Modified 0.101 2.30 10028-17-8 PCl/G u 3.98 6.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Uranium-232 R

DOE EML HASL-300, U-02-RC Modified 0.0496 0.0715 14158-29-3 PCl/G 0.0863 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Uranium-233/234 R

DOE EML HASL-300, U-02-RC Modified 0.847 0.220 13968-55-3/139 PCl/G 0.105 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Uranium-235/236 R

DOE EML HASL-300, U-02-RC Modified 0.0502 0.0636 15117-96-1/139 PCl/G 0.079 1.00 1.00 20.3 BGA1.1.4 SAMPLE 1/12/2016 388119 Uranium-238 R

DOE EML HASL-300, U-02-RC Modified 0.730 0.203 7440-61-1 PCl/G 0.0869 1.00 1.00 20.3 BGA1.1.5 SAMPLE 1/4/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0103 0.190 14952-40-0 PCl/G u 0.355 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.139 0.339 14952-40-0 PCl/G u 0.659 1.00 23.8 BGA1.1.5 SAMPLE 1/11/2016 388119 ALPHA R

EPA 900.0/SW846 9310/SM 711 OB Modified 15.9 3.56 12587-46-1 PCl/G 3.41 4.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Americium-241 R

DOE EML HASL-300, Am-05-RC Modified 0.00962 0.0535 14596-10-2 PCl/G u 0.102 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0414 0.0774 14234-35-6 PCl/G u 0.141 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Antimony-125 R.

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0346 0.122 14234-35-6 PCl/G u 0.232 1.00 23.8 BGA1.1.5 SAMPLE 1/11/2016 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 27.1 3.05 12587-47-2 PCl/G 3.11 10.0 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00.

0.634 14913-49-6 PCl/G UI 1.24 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 1.03 14913-49-6 PCl/G UI 1.57 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.974 0.142 14733-03-0 PCl/G 0.130 1.00 23.8 I

BGA1.1.5 SAMPLE 1/20/2016 388119 Bism uth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.02 0.224 14733-03-0 PCl/G 0.141 1.00 23.8 BGA1.1.5 SAMPLE 1/19/2016 388119 Carbon-14 R

EPA EERF C-01 Modified

-0.512 0.792 14762-75-5 PCl/G u 1.37 2.00 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.138 0.0683 10045-97-3 PCl/G 0.0821 0.100 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.147 0.0731 10045-97-3 PCl/G 0.0901 0.100 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00687 0.045 10198-40-0 PCl/G u 0.0864 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0204 0.0402 10198-40-0 PCl/G u 0.0738 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Curium-242 R

DOE EML HASL-300, Am-05-RC Modified 0.00 0.0404 OER-100-93 PCl/G 0.0602 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Curium-243/244 R

DOE EML HASL-300, Am-05-RC Modified 0.0365 0.0626 PCl/G 0.0548 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Curium-245/246 R

DOE EML HASL-300, Am-05-RC Modified.

0.00 0.0427 PCl/G 0.0635 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.120 0.156 15585-10-1 PCl/G u 0.271 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0712 0.147 15585-10-1 PCl/G u 0.268 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 lodine-129 R

DOE EML HASL-300,1-01 Modified 0.0755 0.352 15046-84-1 PCl/G u 0.767 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Lead-210 R

DOE HASL 300, 4.5.2.3/Ga-01-R 2.26 0.726 14255-04-0 PCl/G 0.596 4.00 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.33 0.0985 15092-94-1 PCl/G 0.0763 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.33 0.158 15092-94-1 PCl/G 0.140 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.987 0.144 15067-28-4 PCl/G 0.108 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.29 0.201 15067-28-4 PCl/G 0.187 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Neptunium-237 R

ASTM C 1476-00 Modified 0.00 0.147 13994-20-2 PCl/G 0.218 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Plutonium-238 R

DOE EML HASL-300, Pu-11-RC Modified 0.0457 0.0678 13981-16-3 PCl/G 0.0991 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Plutonium-239/240 R

DOE EML HASL-300, Pu-11-RC Modified 0.0012 0.0553 OER-100-70 PCl/G u 0.121 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/14/2016 388119 Plutonium-241 R

DOE EML HASL-300, Pu-11-RC Modified

-4.61 6.11 14119-32-5 PCl/G u 10.8 15.0 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.8 1.39 13966-00-2 PCl/G 0.659 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.6 1.60 13966-00-2 PCl/G 0.754 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.585 14331-85-2 PCl/G UI 0.691 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.695 14331-85-2 PCl/G UI 1.34 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.974 0.142 13982-63-3 PCl/G 0.130 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.02 0.224 13982-63-3 PCl/G 0.141 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.10 0.362 15262-20-1 PCl/G 0.301 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.47 0.344 15262-20-1 PCl/G 0.289 1.00 23.8 BGA1.1.5 SAMPLE 1/6/2016 388119

EPA 905.0 Modified/DOE RP501 Rev. 1 Modified

-0.319 0.841 10098-97-2 PCl/G u 1.72 2.00 1.00 23.8 BGA1.1.5 SAMPLE 1/19/2016 388119 Technetium-99 R

DOE EML HASL-300, Tc-02-RC Modified

-0.48 2.20 14133-76-7 PCl/G u 3.87 5.00 1.00 23.8

Backgroun ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA1.1.5 SAMPLE 1/4/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.376 0.0762 14913-50-9 PCl/G 0.0638 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.348 0.0995 14913-50-9 PCl/G 0.0845 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Thorium-228 R

DOE EML HASL-300, Th-01-RC Modified 0.998 0.610 14274-82-9 PCl/G 0.524 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Thorium-229 R

DOE EML HASL-300, Th-01-RC Modified 0.143 0.281 15594-54-4 PCl/G 0.389 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Thorium-230 R

DOE EML HASL-300, Th-01-RC Modified 0.632 0.511 14269-63-7 PCl/G 0.568 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Thorium-232 R

DOE EML HASL-300, Th-01-RC Modified 1.45 0.691 7440-29-1 PCl/G 0.242 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/4/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.065 PCl/G UI 0.0656 1.00 23.8 BGA1.1.5 SAMPLE 1/20/2016 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.157 PCl/G UI 0.146 1.00 23.8 BGA1.1.5 SAMPLE 1/11/2016 388119 Tritium R

EPA 906.0 Modified 1.29 2.38 10028-17-8 PCl/G u 4.05 6.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Uranium-232 R

DOE EML HASL-300, U-02-RC Modified 0.013 0.0487 14158-29-3 PCl/G u 0.0818 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Uranium-233/234 R

DOE EML HASL-300, U-02-RC Modified 0.644 0.235 13968-55-3/139 PCl/G 0.117 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/'2016 388119 Uranium-235/236 R

DOE EML HASL-300, U-02-RC Modified 0.0212 0.0595 15117-96-1/139 PCl/G 0.0635 1.00 1.00 23.8 BGA1.1.5 SAMPLE 1/12/2016 388119 Uranium-238 R

DOE EML HASL-300, U-02-RC Modified 0.670 0.238 7440-61-1 PCl/G 0.101 1.00 1.00 23.8 BGA1.2.1 SAMPLE 1/4/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0242 0.188 14952-40-0 PCl/G u 0.338 1.00 25.3 BGA1.2.1 SAMPLE 1/20/2016 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.137 0.289 14952-40-0 PCl/G u 0.514 1.00 25.3 BGA1.2.1 SAMPLE 1/11/2016 388119 ALPHA R

EPA 900.0/SW846 931 O/SM 711 OB Modified 19.7 4.53 12587-46-1 PCl/G 3.23 4.00 1.00 25.3 BGA1.2.1 SAMPLE 1/4/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0359 0.0799 14234-35-6 PCl/G u 0.128 1.00 25.3 BGA1.2.1 SAMPLE 1/20/2016 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0241 0.114 14234-35-6 PCl/G u 0.211 1.00 25.3 BGA1.2.1 SAMPLE 1/11/2016 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 23.8 3.42 12587-47-2 PCl/G 3.91 10.0 1.00 25.3 BGA1.2.1 SAMPLE 1/4/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.726 0.653 14913-49-6 PCl/G 0.631 1.00 25.3 BGA1.2.1 SAMPLE 1/20/2016 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 1.06 14913-49-6 PCl/G UI 0.968 1.00 25.3 BGA1:2.1 SAMPLE 1/4/2016.

388119 Bismuth-214

  • R DOE HASL 300, 4.5.2.3/Ga-01-R
  • 0.758 0.102 14733-03-0 PCl/G 0.0887 1.00 25.3 BGA1.2.1 SAMPLE 1/20/2016 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.987 0.171 14733-03-0 PCl/G 0.129 1.00 25.3 BGA1.2.1 SAMPLE 1/4/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.228 0.071 10045-97-3 PCl/G 0.0449 0.100 1.00 25.3 BGA1.2.1 SAMPLE 1/20/2016 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.206 0.0839 10045-97-3 PCl/G 0.0956 0.100 1.00 25.3 BGA1.2.1 SAMPLE 1/4/2016 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00185 0.0276 10198-40-0 PCl/G u 0.0513 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00495 0.0479 10198-40-0 PCl/G u 0.0939 1.00 25.3 BGA1.2.1 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

. 0.00 0.0963 15585-10-1 PCl/G UI 0.163 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0883 0.125 15585-10-1 PCl/G u 0.213 1.00 25.3 BGA1.2.1 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.01 0.0906 15092-94-1 PCl/G 0.077 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.892 0.128 15092-94-1 PCl/G 0.121 1.00 25.3 BGA1.2.1 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.02 0.127 15067-28-4 PCl/G 0.210 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.901 0.214 15067-28-4 PCl/G 0.141 1.00 25.3 BGA1.2.1 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 13.8 1.16 13966-00-2 PCl/G 0.470 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.7 1.53 13966-00-2 PCl/G 0.550 1.00 25.3 BGA1.2.1 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.407 14331-85-2 PCl/G UI 0.681 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0225 0.647 14331-85-2 PCl/G u 1.14 1.00 25.3 BGA1.2.1 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.758 0.102 13982-63-3 PCl/G 0.0887 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.987 0.171 13982-63-3 PCl/G 0.129 1.00 25.3 BGA1.2.1 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.891 0.201 15262-20-1 PCl/G 0.160 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.722 0.376 15262-20-1 PCl/G 0.360 1.00 25.3 BGA1.2.1 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.287 0.0617 14913-50-9 PCl/G 0.0438 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.265 0.0727 14913-50-9 PCl/G 0.0728 1.00 25.3 BGA1.2.1 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0911 PCl/G UI 0.110 1.00 25.3 BGA1.2.1 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.140 PCl/G UI 0.177 1.00 25.3 BGA1.2.2 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.041 0.209 14952-40-0 PCl/G u 0.398 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.199 0.317 14952-40-0 PCl/G u 0.619 1.00 18.8 BGA1.2.2 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 17.1 3.52 12587-46-1 PCl/G 3.36 4.00 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0116 0.080 14234-35-6 PCl/G u 0.144 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0697 0.120 14234-35-6 PCl/G u 0.207 1.00 18.8

Background ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA1.2.2 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 21.5 2.70 12587-47-2 PCl/G 2.80 10.0 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.51 0.591 14913-49-6 PCl/G 0.731 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.897 14913-49-6 PCl/G UI 1.50 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.915 0.136 14733-03-0 PCl/G 0.108 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.934 0.202 14733-03-0 PCl/G 0.178 1.00 18.8 BGA1.2.2.

SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.185 0.0502 10045-97-3 PCl/G 0.0548 0.100 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.178 0.092 10045-97-3 PCl/G 0.0999 0.100 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0141 0.0331 10198-40-0 PCl/G u 0.0657 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0237 0.0465 10198-40-0 PCl/G u 0.0861 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0841 0.119 15585-10-1 PCl/G u 0.235 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0872 0.152 15585-10-1 PCl/G u 0.274 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.12 0.0982 15092-94-1 PCl/G 0.083 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.32 0.153 15092-94-1 PCl/G 0.134 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.21 0.148 15067-28-4 PCl/G 0.269 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.24 0.205 15067-28-4 PCl/G 0.168 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.7 1.19 13966-00-2 PCl/G 0.423 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.8 1.71 13966-00-2 PCl/G 0.841 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.498 14331-85-2 PCl/G UI 0.624 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.677 14331-85-2 PCl/G UI 1.38 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.915 0.136 13982-63-3 PCl/G 0.108 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.934 0.202 13982-63-3 PCl/G 0.178 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.15 0.270 15262-20-1 PCl/G 0.231 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.10 0.344 15262-20-1 PCl/G 0.289 1.00 '

18.8 BGA1.2.2 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.302 0.066 14913-50-9 PCl/G 0.0547 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R

  • 0.360 0.095 14913-50-9 PCl/G 0.0783 1.00 18.8 BGA1.2.2 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.112 PCl/G UI 0.105 1.00 18.8 BGA1.2.2 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.169 PCl/G UI 0.196 1.00 18.8 BGA1.3.1 SAMPLE 42373 388119 Actiriium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.104 0.193 14952-40-0 PCl/G u 0.360 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.205 0.293 14952-40-0 PCl/G u 0.518 1.00 42.6 BGA1.3.1 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 711 OB Modified 11.8 3.23 12587-46-1 PCl/G 3.61 4.00 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0505 0.0785 14234-35-6 PCl/G u 0.144 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0316 0.110 14234-35-6 PCl/G (J

0.196 1.00 42.6 BGA1.3.1 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 21.8 2.94 12587-47-2 PCl/G 3.45 10.0 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.32 0.565 14913-49-6 PCl/G 0.663 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.819 14913-49-6 PCl/G UI 1.51 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.791 0.115 14733-03-0

  • PCl/G 0.0959 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.02 0.177 14733-03-0 PCl/G 0.144 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.328 0.0532 10045-97-3 PCl/G 0.0538 0.100 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.354 0.0766 10045-97-3 PCl/G 0.0703 0.100 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.000158 0.0319 10198-40-0 PCl/G u 0.0588 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0406 0.0557 10198-40-0 PCl/G u 0.095 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0688 0.090 15585-10-1 PCl/G u 0.152 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0171 0.114 15585-10-1 PCl/G u 0.233 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.03 0.0913 15092-94-1 PCl/G 0.0813 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.964 0.126 15092-94-1 PCl/G 0.115 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.04 0.128 15067-28-4 PCl/G 0.236 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.10 0.190 15067-28-4 PCl/G 0.162 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119.

Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.3 1.01 13966-00-2 PCl/G 0.422 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 13.2 1.62 13966-00-2 PCl/G 0.683 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.557 14331-85-2 PCl/G UI 0.615 1.00 42.6

Backgroun ackground Sample No. Type Analyz_ed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA1.3.1 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.352 0.882 14331-85-2 PCl/G u 1.02 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.791 0.115 13982-63-3 PCl/G 0.0959 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.02 0.177 13982-63-3 PCl/G 0.144 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.04 0.209 15262-20-1 PCl/G 0.177 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.953 0.287 15262-20-1 PCl/G 0.272 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.265 0.0647 14913-50-9 PCl/G 0.0506 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.258 0.0895 14913-50-9 PCl/G 0.0752 1.00 42.6 BGA1.3.1 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0852 PCl/G UI 0.077 1.00 42.6 BGA1.3.1 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.102 PCl/G UI 0.130 1.00 42.6 BGA1.3.2 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0251 0.216 14952-40-0 PCl/G u 0.389 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0671 0.372 14952-40-0 PCl/G u 0.683 1.00 22.8 BGA1.3.2 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 16.5 3.79 12587-46-1 PCl/G 3.43 4.00 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00835 0.0791 14234-35-6 PCl/G u 0:141 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0362 0.148 14234-35-6 PCl/G u 0.274 1.00 22.8 BGA1.3.2 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 21.8 2.81 12587-47-2 PCl/G 3.15 10.0 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.22 0.706 14913-49-6 PCl/G 0.739 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.810 0.901 14913-49-6 PCl/G u 1.93 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.837 0.137 14733-03-0 PCl/G 0.115 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.01 0.252 14733-03-0 PCl/G 0.229 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.284 0.0735 10045-97-3 PCl/G 0.0611 0.100 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.299 0.137 10045-97-3 PCl/G 0.136 0.100 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2:3/Ga-01-R

-0.0051 0.0285 10198-40-0 PCl/G u 0.0522 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00414 0.0597 10198-40-0 PCl/G u 0.122 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0753 0.107 15585-10-1 PCl/G u 0.170 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.132 15585-10-1 PCl/G UI 0.387 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.19 0.0991 15092-94-1 PCl/G 0.0829 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.27 0.172 15092-94-1 PCl/G 0.165 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.12 0.160 15067-28-4 PCl/G 0.259 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.15 0.302 15067-28-4 PCl/G 0.202 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.6 1.29 13966-00-2 PCl/G 0.537 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.6 2.22 13966-00-2 PCl/G 1.15 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.478 14331-85-2 PCl/G UI 0.696 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.953 14331-85-2 PCl/G UI 1.19 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.837 0.137 13982-63-3 PCl/G 0.115 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.01 0.252 13982-63-3 PCl/G 0.229 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.12 0.269 15262-20-1 PCl/G 0.229 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.29 0.421 15262-20-1 PCl/G 0.396 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.322 0.0541 14913-50-9 PCl/G 0.0545 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.425 0.119 14913-50-9 PCl/G 0.0976 1.00 22.8 BGA1.3.2 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.106 PCl/G UI 0.110 1.00 22.8 BGA1.3.2 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.145 PCl/G UI 0.173 1.00 22.8 BGA1.4.1 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0795 0.184 14952-40-0 PCl/G u 0.334 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0553 0.311 14952-40-0 PCl/G u 0.591 1.00 33.2 BGA1.4.1 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 10.8 3.17 12587-46-1 PCl/G 3.92 4.00 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00677 0.0659 14234-35-6 PCl/G u 0.122 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0409 0.122 14234-35-6 PCl/G u 0.220 1.00 33.2 BGA1.4.1 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 20.0 2.79 12587-47-2 PCl/G 3.35 10.0 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.562 0.471 14913-49-6 PCl/G 0.700 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.992 14913-49-6 PCl/G UI 1.54 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.749 0.132 14733-03-0 PCl/G 0.0953 1.00 33.2

Background ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units LabQu MDL CRDL Dilution % Moist1 BGA1.4.1 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.965 0.191 14733-03-0 PCl/G 0.164 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.260 0.0542 10045-97-3 PCl/G 0.0569 0.100 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.232 0.0868 10045-97-3 PCl/G 0.0891 0.100 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00557 0.0266 10198-40-0 PCl/G u 0.051 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0271 0.0479 10198-40-0 PCl/G u 0.103 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0608 0.0935 15585-10-1 PCl/G u 0.158 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0468 0.154 15585-10-1 PCl/G u 0.283 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.03 0.0865 15092-94-1 PCl/G 0.0754 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.986 0.154 15092-94-1 PCl/G 0.128 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.986 0.124 15067-28-4 PCl/G 0.0995 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.05 0.206 15067-28-4 PCl/G 0.382 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 11.4 1.01 13966-00-2 PCl/G 0.467 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.8 1.60 13966-00-2 PCl/G 0.834 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.524 14331-85-2 PCl/G UI 0.616 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.191 0.683 14331-85-2 PCl/G u 1.19 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.749 0.132 13982-63-3 PCl/G 0.0953 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.965 0.191 13982-63-3 PCl/G 0.164 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.729 0.190 15262-20-1 PCl/G 0.175 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.15 0.297 15262-20-1 PCl/G 0.316 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.226 0.0523 14913-50-9 PCl/G 0.0517 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.301 0.0957 14913-50-9 PCl/G 0.0847 1.00 33.2 BGA1.4.1 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0881 PCl/G UI 0.0983 1.00 33.2 BGA1.4.1 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0994 0.141 PCl/G u 0.263 1.00 33.2 BGA1.4.2 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0875 0.181 14952-40-0 PCl/G u 0.289 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.042 0.260 14952-40-0 PCl/G u 0.490 1.00 22 BGA1.4.2 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 13.6 3.55 12587-46-1 PCl/G 3.94 4.00 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0107 0.0647 14234-35-6 PCl/G u 0.117 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00353 0.0985 14234-35-6 PCl/G u 0.179 1.00 22 BGA1.4.2 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 931 O/SM 711 OB Modified 20.0 2.67 12587-47-2 PCl/G 3.04 10.0 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.634 14913-49-6 PCl/G UI 0.850 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.598 14913-49-6 PCl/G UI 1.16 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.654 0.130 14733-03-0 PCl/G 0.0828 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.889 0.169 14733-03-0 PCl/G 0.137 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.188 0.0539 10045-97-3 PCl/G 0.0457 0.100 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.215 0.0782 10045-97-3 PCl/G 0.0609 0.100 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00729 0.0276 10198-40-0 PCl/G u 0.0525 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0209 0.0343 10198-40-0 PCl/G u 0.0482 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.S.2.3/Ga-01-R 0.00 0.0769 15585-10-1 PCl/G UI 0.162 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00916 0.091 15585-10-1 PCl/G u 0.180 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.02 0.088 15092-94-1 PCl/G 0.0697 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Lead-212 R.

DOE HASL 300, 4.5.2.3/Ga-01-R 1.18 0.123 15092-94-1 PCl/G 0.100 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.968 0.123 15067-28-4 PCl/G 0.0908 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.950 0.175 15067-28-4 PCl/G 0.143 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 11.9 0.981 13966-00-2 PCl/G 0.367 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 11.7 1.37 13966-00-2 PCl/G 0.571 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.472 14331-85-2 PCl/G UI 0.584 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.646 14331-85-2 PCl/G UI 0.803 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.654 0.130 13982-63-3 PCl/G 0.0828 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.889 0.169 13982-63-3 PCl/G 0.137 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.784 0.199 15262-20-1 PCl/G 0.167 1.00 22

Backgroun Sample No. Ty e Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA1.4.2 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.945 0.227 15262-20-1 PCl/G 0.212 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.274 0.0594 14913-50-9 PCl/G 0.0434 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.313 0.0725 14913-50-9 PCl/G 0.0624 1.00 22 BGA1.4.2 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0816 PCl/G UI 0.0809 1.00 22 BGA1.4.2 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.122 PCl/G UI 0.124 1.00 22 BGA1.5.1 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0237 0.279 14952-40-0 PCl/G u 0.517 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.25 0.269 14952-40-0 PCl/G u 0.456 1.00 27.6 BGA1.5.1 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 931 O/SM 711 OB Modified 13.2 3.60 12587-46-1 PCl/G 3.89 4.00 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0439 0.113 14234-35-6 PCl/G u 0.209

~ 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.289 14234-35-6 PCl/G UI 0.192 1.00 27.6 BGA1.5.1 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 30.3 3.31 12587-47-2 PCl/G 3.56 10.0 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.914 14913-49-6 PCl/G UI 1.33 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.847 14913-49-6 PCl/G UI 1.43 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.959 0.160 14733-03-0 PCl/G 0.141 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Bismuth-214.

R DOE HASL 300, 4.5.2.3/Ga-01-R 1.10 0.198 14733-03-0 PCl/G 0.146 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.337 0.0867 10045-97-3 PCl/G 0.0828 0.100 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.391 0.0852 10045-97-3 PCl/G 0.0851 0.100 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00312 0.0437 10198-40-0 PCl/G u 0.084 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0127 0.0439 10198-40-0 PCl/G u 0.0823 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.138 15585-10-1 PCl/G UI 0.295 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.134 0.184 15585-10-1 PCl/G u 0.254 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.16 0.127 15092-94-1 PCl/G 0.116

. 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.09 0.121 15092-94-1 PCl/G 0.126 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.04 0.180 15067-28-4 PCl/G 0.318 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.18 0.175 15067-28-4 PCl/G 0.152 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 11.7 1.43 13966-00-2 PCl/G 0.676 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.5 1.46 13966-00-2 PCl/G 0.692 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.413 0.587 14331-85-2 PCl/G u 1.08 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.828 14331-85-2 PCl/G UI 0.916 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.959 0.160 13982-63-3 PCl/G 0.141 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.10 0.198 13982-63-3 PCl/G 0.146 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.801 0.349 15262-20-1 PCl/G 0.274 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.01 0.299 15262-20-1 PCl/G 0.300 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.314 0.0879 14913-50-9 PCl/G 0.0738 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.267 0.0959 14913-50-9 PCl/G 0.0704 1.00 27.6 BGA1.5.1 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0903 PCl/G UI 0.0929 1.00 27.6 BGA1.5.1 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0914 PCl/G UI 0.128 1.00 27.6 BGA1.5.2 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.018 0.229 14952-40-0 PCl/G u 0.413 1.00 21.2 BGA1.5.2 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.179 0.275 14952-40-0 PCl/G u 0.518 1.00 21.2 BGA1.5.2 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 11.4 3.40 12587-46-1 PCl/G 4.05 4.00 1.00 21.2 BGA1.5.2 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0897 14234-35-6 PCl/G UI 0.149 1.00 21.2 BGA1.5.2 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00353 0.102 14234-35-6 PCl/G u 0.186 1.00 21.2 BGA1.5.2 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 711 OB Modified 20.7 2.90 12587-47-2 PCl/G 3.22 10.0 1.00 21.2 BGA1.5.2 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.533 14913-49-6 PCl/G UI 1.02 1.00 21.2 BGA1.5.2 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.924 14913-49-6 PCl/G UI 0.913 1.00 21.2 BGA1.5.2 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.740 0.150 14733-03-0 PCl/G 0.109 1.00 21.2 BGA1.5.2 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.895 0.179 14733-03-0 PCl/G 0.127 1.00 21.2 BGA1.5.2 SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.220 0.0693 10045-97-3 PCl/G 0.0563 0.100 1.00 21.2 BGA1.5.2 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.241 0.079 10045-97-3 PCl/G 0.078 0.100 1.00 21.2 BGA1.5.2 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0138 0.030 10198-40-0 PCl/G u 0.061 1.00 21.2

Background ackground Sample No. Type Analyzed SDG Parameter Fraction Method BGA1.5.2 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA1.5.2 MSD 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified BGA1.5.2 MSD 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified BGA1.5.2 MS 42383 388119 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified BGA1.5.2 MS 42383 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified BGA1.5.2 DUP 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified BGA1.5.2 DUP 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 711 OB Modified BGA2.1.1 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 931 O/SM 711 OB Modified BGA2.1.1 SAMPLE 42381 388119 Americium-241 R

DOE EML HASL-300, Am-05-RC Modified BGA2.1.1 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified BGA2.1.1 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42388 388119 Carbon-14 R

EPA EERF C-01 Modified BGA2.1.1 SAMPLE 42373 388119 Cesium-137 R

DOE.HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42381 388119 Curium-242 R

DOE EML HASL-300, Am-05-RC Modified BGA2.1.1 SAMPLE 42381 388119 Curium-243/244 R

DOE EML HASL-300, Am-05-RC Modified BGA2.1.1 SAMPLE 42381 388119 Curium-245/246 R

DOE EML HASL-300, Am-05-RC Modified BGA2.1.1 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42389 388119 lodine-129 R

DOE EML HASL-300,1-01 Modified BGA2.1.1 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R BGA2.1.1 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R Result Uncertainty CAS

-0.0111 0.0361 10198-40-0 0.00543 0.107 15585-10-1

-0.0451 0.111 15585-10-1 1.00 0.102 15092-94-1 1.12 0.121 15092-94-1 1.04 0.164 15067-28-4 1.12 0.156 15067-28-4 12.7 1.11 13966-00-2 12.8 1.21 13966-00-2 0.317 0.551 14331-85-2 0.00 0.650 14331-85-2 0.740 0.150 13982-63-3 0.895 0.179 13982-63-3 0.00 0.218 15262-20-1 1.01 0.257 15262-20-1 0.358 0.0662 14913-50-9 0.309 0.085 14913-50-9 0.00 0.0913 0.00 0.117 114 16.0 12587-46-1 117 17.9 12587-47-2 75.5 13.5 12587-46-1 120 18.9 12587-47-2 10.8 3.35 12587-46-1 24.2 3.42 12587-47-2

-0.0573 0.237 14952-40-0 0.114 0.379 14952-40-0 9.23 3.11 12587-46-1

-0.0317 0.0399 14596-10-2

-0.0159 0.0898 14234-35-6 0.107 0.138 14234-35-6 15.0 2.62 12587-47-2 0.00 0.651 14913-49-6 0.00 0.762 14913-49-6 0.550 0.116 14733-03-0 0.688 0.199 14733-03-0

-0.12 1.00 14762-75-5 0.646 0.0907 10045-97-3 0.769 0.127 10045-97-3

-0.00335 0.0336 10198-40-0

-0.0248 0.0464 10198-40-0 0.0136 0.051 OER-100-93 0.00457 0.0477 0.0287 0.066

-0.0293 0.090 15585-10-1

-0.0558 0.150 15585-10-1

-0.0504 0.472 15046-84-1 0.513 0.0947 15092-94-1 0.692 0.128 15092-94-1 0.618 0.144 15067-28-4 Units Lab Qu MDL PCl/G u 0.0657 PCl/G u 0.201 PCl/G u 0.199 PCl/G 0.0894 PCl/G 0.109 PCl/G 0.268 PCl/G 0.136 PCl/G 0.572 PCl/G 0.659 PCl/G u 0.762 PCl/G UI 0.907 PCl/G 0.109 PCl/G 0.127 PCl/G UI 0.425 PCl/G 0.273 PCl/G 0.0556 PCl/G 0.0664 PCl/G UI 0.125 PCl/G UI 0.164 6.42 4.17 6.49 3.93 PCl/G 3.98 PCl/G 4.00 PCl/G u 0.423 PCl/G u 0.685 PCl/G 3.78 PCl/G u 0.133 PCl/G u 0.158 PCl/G u 0.272 PCl/G 3.19 PCl/G UI 0.950 PCl/G UI 1.61 PCl/G 0.108 PCl/G 0.200 PCl/G u 1.72 PCl/G 0.0647 PCl/G 0.0823 PCl/G u 0.0642 PCl/G u 0.0807 PCl/G u 0.0858 PCl/G u 0.0996 PCl/G 0.105 PCl/G u 0.167 PCl/G u 0.269 PCl/G u 0.928 PCl/G 0.108 PCl/G 0.140 PCl/G 0.249 CRDL 4.00 10.0 4.00 10.0 4.00 10.0 4.00 1.00 10.0 2.00 0.100 0.100 1.00 1.00 1.00 1.00 Dilution % Moist1 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 21.2 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 1.00 39.4 J

Backgroun Sample No. Ty e Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA2.1.1 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.819 0.193 15067-28-4 PCl/G 0.393 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Neptunium-237 R

ASTM C 1476-00 Modified

-0.0585 0.264 13994-20-2 PCl/G u 0.666 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Plutonium-238 R

DOE EML HASL-300, Pu-11-RC Modified

-0.0073 0.0323 13981-16-3 PCl/G u 0.0843 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Plutonium-239/240 R

DOE EML HASL-300, Pu-11-RC Modified 0.0195 0.0536 OER-100-70 PCl/G u 0.0929 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42383 388119 Plutonium-241 R

DOE EML HASL-300, Pu-11-RC Modified

-9.13 6.96 14119-32-5 PCl/G u 12.5 15.0 1.00 39.4 BGA2.1.1 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 6.95 1.01 13966-00-2 PCl/G 0.562 1.00 39.4 BGA2.1.1 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 6.78 1.27 13966-00-2 PCl/G 0.930 1.00 39.4 BGA2.1.1 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.793 14331-85-2 PCl/G UI 0.732 1.00 39.4 BGA2.1.1 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.104 0.747 14331-85-2 PCl/G u 1.28 1.00 39.4 BGA2.1.1 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.550 0.116 13982-63-3 PCl/G 0.108 1.00 39.4 BGA2.1.1 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.688 0.199 13982-63-3 PCl/G 0.200 1.00 39.4

  • BGA2.1.1 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.270 15262-20-1 PCl/G UI 0.454 1.00 39.4 BGA2.1.1 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.248 15262-20-1 PCl/G UI 0.546 1.00 39.4 BGA2.1.1*

SAMPLE 42375 388119 Strontium-90 R

EPA 905.0 Modified/DOE RP501 Rev. 1 Modified

-0.638 0.832 10098-97-2 PCl/G u 1.76 2.00 1.00

'39.4 BGA2.1.1 SAMPLE 42388 388119 Technetium-99 R

DOE EML HASL-300, Tc-02-RC Modified

-0.715 2.78 14133-76-7 PCl/G u 4.91 5.00 1.00.

39.4 BGA2.1.1 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.158 0.0635 14913-50-9 PCl/G 0.0621 1.00 39.4 BGA2.1.1 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.181 0.115 14913-50-9 PCl/G 0.092 1.00 39.4 BGA2:'1.1 SAMPLE 42381 388119 Thorium-228 R

DOE EML HASL-300, Th-01-RC Modified 0.584 0.535 14274-82-9 PCl/G 0.498 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Thorium-229 R

DOE EML HASL-300, Th-01-RC Modified 0.00 0.203 15594-54-4 PCl/G 0.303 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Thorium-230 R

DOE EML HASL-300, Th-01-RC Modified 0.733 0.599 14269-63-7 PCl/G 0.615 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Thorium-232 R

DOE EML HASL-300, Th-01-RC Modified 1.20 0.711 7440-29-1 PCl/G 0.301 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga~01-R 0.00 0.0987 PCl/G UI 0.112 1.00 39.4 BGA2.1.1 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0534 0.128 PCl/G u 0.210 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Tritium R

EPA 906.0 Modified 0.867 3.05 10028-17-8 PCl/G u 5.24 6.00 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Uranium-232 R

DOE EML HASL-300, U-02-RC Modified 0.0228 0.114 14158-29-3 PCl/G u 0.227 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Uranium-233/234 R

DOE EML HASL-300, U-02-RC Modified 0.775 0.411 13968-55-3/139 PCl/G 0.368 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Uranium-235/236 R

DOE EML HASL-300, U-02-RC Modified 0.0495 0.169 15117-96-1/139 PCl/G u 0.314 1.00 1.00 39.4 BGA2.1.1 SAMPLE 42381 388119 Uranium-238 R

DOE EML HASL-300, U-02-RC Modified 0.690 0.374 7440-61-1 PCl/G 0.263 1.00 1.00 39.4 BGA2.1.2 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0855 0.169 14952-40-0 PCl/G u 0.327 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0727 0.203 14952-40-0 PCJ/G u 0.405 1.00 29 BGA2.1.2 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 6.21 2.78 12587-46-1 PCJ/G 3.75 4.00 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.023 0.0617 14234-35-6 PCl/G u 0.108 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.049 0.0737 14234-35-6 PCl/G u 0.151 1.00 29 BGA2.1.2 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 16.9 2.73 12587-47-2 PCl/G 3.25 10.0 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.394 14913-49-6 PCl/G UI 0.782 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.11 0.730 14913-49-6 PCJ/G 0.748 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.622 0.0988 14733-03-0 PCl/G 0.0855 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.697 0.165 14733-03-0 PCl/G 0.121 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0421 0.0404 10045-97-3 PCl/G 0.0501 0.100 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0238 0.0366 10045-97-3 PCl/G u 0.0753 0.100 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.000729 0.0259 10198-40-0 PCl/G u 0.0511 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0115 0.0345 10198-40-0 PCl/G u 0.0643 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0571 0.177 15585-10-1 PCl/G u 0.148 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0429 0.0913 15585-10-1 PCl/G u 0.199 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.814 0.0842 15092-94-1 PCl/G 0.075 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.802 0.106 15092-94-1 PCl/G 0.079 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.799 0.130 15067-28-4 PCl/G 0.218 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.908 0.141 15067-28-4 PCl/G 0.105 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 7.51 0.844 13966-00-2 PCJ/G 0.402 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 8.30 1.10 13966-00-2 PCJ/G 0.105 1.00 29

Background ackground Sample No.. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab.Ou MDL CRDL Dilution % Moistt

  • BGA2.1.2 SAMPLE 42373 388119 Protactinium-231 R

. DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.407 14331-85-2 PCl/G UI 0.737 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.295 0.576 14331-85-2 PCl/G u 0.789 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.622 0.0988 13982-63-3 PCl/G 0.0855 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.697 0.165 13982-63-3 PCl/G 0.121 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.719 0.195 15262-20-1 PCl/G 0.209 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.880 0.266 15262-20-1 PCl/G 0.214 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.236 0.0559 14913-50-9 PCl/G 0.0392 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.178 0.0626 14913-50-9 PCl/G 0.0582 1.00 29 BGA2.1.2 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0799 PCl/G UI 0.0968 1.00 29 BGA2.1.2 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0828 PCl/G UI 0.0856 1.00 29 BGA2.1.3 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00612 0.188 14952-40-0 PCl/G u 0.355 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0587 0.247 14952-40-0 PCl/G u 0.488 1.00 20.7 BGA2.1.3 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 931 O/SM 71108 Modified 12.0 3.16 12587-46-1 PCl/G 3.81 4.00 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0248 0.0711 14234-35-6 PCl/G u 0.127 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0904 0.203 14234-35-6 PCl/G u 0.208 1.00 20.7 BGA2.1.3 SAMPLE 42380.388119 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 21.4 2.56 12587-47-2 PCl/G 2.74 10.0 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.642 14913-49-6 PCl/G UI 0.979 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.689 14913-49-6 PCl/G UI 1.50 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.737 0.142 14733-03-0 PCl/G 0.0964 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.808 0.216 14733-03-0 PCl/G 0.148 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00545 0.0263 10045-97-3 PCl/G u 0.0487 0.100 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0157 0.0492 10045-97-3 PCl/G u 0.0896 0.100 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0184 0.0299 10198-40-0 PCl/G u 0.055 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0456 0.0544 10198-40-0 PCl/G u 0.122 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00608 0.102 15585-10-1 PCl/G u 0.166 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0917 0.179 15585-10-1 PCl/G u 0.373 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.940 0.0898 15092-94-1 PCl/G 0.0733 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.01 0.121 15092-94-1 PCl/G 0.0941 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.04 0.143 15067-28-4 PCl/G 0.0993 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.949 0.185 15067-28-4 PCl/G 0.163 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.9 1.06 13966-00-2 PCl/G 0.430 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 11.4 1.66 13966-00-2 PCl/G 0.787 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.526 14331-85-2 PCl/G UI 0.599 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.264 0.603 14331-85-2 PCl/G u 1.06 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.737 0.142 13982-63-3 PCl/G 0.0964 1.00 20.7

DOE HASL 300, 4.5.2.3/Ga-01-R 0.808 0.216 13982-63-3 PCl/G 0.148 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.860 0.210 15262-20-1 PCl/G 0.180 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.783 0.296 15262-20-1 PCl/G 0.440 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.300 0.0573.

14913-50-9 PCl/G 0.044 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.225 0.0966 14913-50-9 PCl/G 0.0737 1.00 20.7 BGA2.1.3 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0496 0.118 PCl/G u 0.119 1.00 20.7 BGA2.1.3 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.083 PCl/G UI 0.0788 1.00 20.7 BGA2.1.4 SAMPLE 42373 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0441 0.260 14952-40-0 PCl/G u 0.453 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0202 0.292 14952-40-0 PCl/G u 0.536 1.00 22 BGA2.1.4 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 19.7 3.82 12587-46-1 PCl/G 2.43 4.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Americium-241 R

DOE EML HASL-300, Am-05-RC Modified 0.0274 0.063 14596-10-2 PCl/G 0.0999 1.00 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0373 0.110 14234-35-6 PCl/G u 0.207 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0796 0.110 14234-35-6 PCl/G u 0.185 1.00 22 BGA2.1.4 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 35.2 3.16 12587-47-2 PCl/G 2.74 10.0 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.173 0.908 14913-49-6 PCl/G u 1.54 1.00 22

Backgroun ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA2.1.4 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.80 1.06 14913-49-6 PCl/G 1.16 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.24 0.185 14733-03-0 PCl/G 0.153 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.990 0.189 14733-03-0 PCl/G 0.140 1.00 22 BGA2.1.4 SAMPLE 42388 388119 Carbon-14 R

EPA EERF C-01 Modified

-0.537 0.766 14762-75-5 PCl/G u 1.33 2.00 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0037 0.0503 10045-97-3 PCl/G u 0.0905 0.100 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0611 0.0503 10045-97-3 PCl/G 0.082 0.100 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.021 0.0446 10198-40-0 PCl/G u 0.093 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0108 0.0486 10198-40-0 PCl/G u 0.089 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Curium-242 R

DOE EML HASL-300, Am-05-RC Modified

-0.00469 0.0405 OER-100-93 PCl/G u 0.0938 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Curium-243/244 R

DOE EML HASL-300, Am-05-RC Modified 0.00926 0.0515 PCl/G u 0.0986 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Curium-245/246 R

DOE EML HASL-300, Am-05-RC Modified 0.00 0.0416 PCl/G 0.0619 1.00 1.00 22 BGA2.1.4

  • SAMPLE 42373 388119 Europium-154 R*

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0938 0.143 15585-10-1 PCl/G u 0.297 1.00 22*

BGA2.1.4 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0959 0.149 15585-10-1 PCl/G u 0.301 1.00 22 BGA2.1.4 SAMPLE 42389 388119 lodine-129 R

DOE EML HASL-300,1-01 Modified

-0.146 0.331 15046-84-1 PCl/G u 0.621 1.00 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.36 0.123 15092-94-1 PCl/G 0.101 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.53 0.140 15092-94-1 PCl/G 0.108 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.10 0.210 15067-28-4 PCl/G 0.147 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.46 0.205 15067-28-4 PCl/G 0.381 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Neptunium-237 R

ASTM C 1476-00 Modified

-0.0358 0.158 13994-20-2 PCl/G u 0.413 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Plutonium-238 R

DOE EML HASL-300, Pu-11-RC Modified 0.00414 0.0471 13981-16-3 PCl/G u 0.100 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Plutonium-239/240 R

DOE EML HASL-300, Pu-11-RC Modified 0.0357 0.0514 OER-100-70 PCl/G 0.062 1.00 1.00 22 BGA2.1.4 SAMPLE 1/2015/2016 388119 Plutonium-241 R

DOE EML HASL-300, Pu-11-RC Modified

-6.29 6.10 14119-32-5 PCl/G u 10.9 15.0 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 23.6 2.02 13966-00-2 PCl/G 0.777 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 25.6 1.94 13966-00-2 PCl/G 0.651 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.437 0.609 14331-85-2 PCl/G u 1.06 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.857 14331-85-2 PCl/G UI 0.983 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.24 0.185 13982-63-3 PCl/G 0.153 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.990 0.189 13982-63-3 PCl/G 0.140 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.21 0.378 15262-20-1 PCl/G 0.336 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.08 0.369 15262-20-1 PCl/G 0.282 1.00 22 BGA2.1.4 SAMPLE 42376 388119 Strontium-90 R

EPA 905.0 Modified/DOE RP501 Rev. 1 Modified

-0.758 0.512 10098-97-2 PCl/G u 1.21 2.00 1.00 22 BGA2.1.4 SAMPLE 42388 388119 Technetium-99 R

DOE EML HASL-300, Tc-02-RC Modified 2.01 2.78 14133-76-7 PCl/G u 4.71 5.00 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.405 0.0953 14913-50-9 PCl/G 0.0723 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.355 0.0809 14913-50-9 PCl/G 0.0811 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Thorium-228 R

DOE EML HASL-300, Th-01-RC Modified 1.06 0.649 14274-82-9 PCl/G 0.553 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Thorium-229 R

DOE EML HASL-300, Th-01-RC Modified 0.218 0.346 15594-54-4 PCl/G 0.478 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Thorium-230 R

DOE EML HASL-300, Th-01-RC Modified 0.820 0.565 14269-63-7 PCl/G 0.477 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Thorium-232 R

DOE EML HASL-300, Th-01-RC Modified 1.03 0.608 7440-29-1 PCl/G 0.258 1.00 1.00 22 BGA2.1.4 SAMPLE 42373 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.128 PCl/G UI 0.118 1.00 22 BGA2.1.4 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.142 PCl/G UI 0.172 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Tritium R

EPA 906.0 Modified 0.719 2.35 10028-17-8 PCl/G u 4.03 6.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Uranium-232 R

DOE EML HASL-300, U-02-RC Modified 0.0136 0.0511 14158-29-3 PCl/G u 0.0859 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Uranium-233/234 R

DOE EML HASL-300, U-02-RC Modified 1.01 0.261 13968-55-3/139 PCl/G 0.111 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Uranium-235/236 R

DOE EML HASL-300, U-02-RC Modified 0.0508 0.0668 15117-96-1/139 PCl/G 0.0508 1.00 1.00 22 BGA2.1.4 SAMPLE 42381 388119 Uranium-238 R

DOE EML HASL-300, U-02-RC Modified 1.10 0.271 7440-61-1 PCl/G 0.103 1.00 1.00 22 BGA2.1.5 SAMPLE 42374 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0321 0.235 14952-40-0 PCl/G u 0.440 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.403 14952-40-0 PCl/G UI 0.637 1.00 40.7 BGA2.1.5 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 4.38 2.43 12587-46-1 PCl/G 3.62 4.00 1.00 40.7 BGA2.1.5 SAMPLE 42382 388119 Americium-241 R

DOE EML HASL-300, Am-05-RC Modified 0.00764 0.0424 14596-10-2 PCl/G u 0.0814 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00271 0.109 14234-35-6 PCl/G u 0.177 1.00 40.7

~*

Background ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty GAS Units Lab Qu MDL CRDL Dilution % Moist!

BGA2.1.5 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0668 0.106 14234-35-6 PCl/G u 0.213 1.00 40.7 BGA2.1.5 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 14.1 2.54 12587-47-2 PCl/G 3.31 10.0 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.570 0.625 14913-49-6 PCl/G 0.735 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.23 0.578 14913-49-6 PCl/G 0.873 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.469 0.170 14733-03-0 PCl/G 0.138 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.526 0.153 14733-03-0 PCl/G 0.153 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Carbon-14 R

EPA EERF C-01 Modified

-0.485 1.02 14762-75-5 PCl/G u 1.76 2.00 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.850 0.122 10045-97-3 PCl/G 0.0792 0.100 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.865 0.110 10045-97-3 PCl/G 0.0589 0.100 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0168 0.0342 10198-40-0 PCl/G u 0.0751 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.019 0.0344 10198-40-0 PCl/G u 0.0665 1.00 40.7 BGA2.1.5 SAMPLE 42382 388119 Curium-242 R

DOE EML HASL-300, Am-05-RC Modified 0.00 0.0323 OER-100-93 PCl/G 0.048 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42382 388119 Curium-243/244 R

DOE EML HASL-300, Am-05-RC Modified 0.0221 0.0507 PCl/G 0.0804 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42382 388119 Curium-245/246 R

DOE EML HASL-300, Am-05-RC Modified 0.0168 0.0473 PCl/G 0.0504 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0534 0.120 15585-10-1 PCl/G u 0.211 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.116 15585-10-1 PCl/G UI 0.316 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 lodine-129 R

DOE EML HASL-300,1-01 Modified

-0.408 0.472 15046-84-1 PCl/G u 0.670 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.648 0.104 15092-94-1 PCl/G 0.100 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.676 0.120 15092-94-1 PCl/G 0.123 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.701 0.140 15067-28-4 PCl/G 0.153 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.777 0.187 15067-28-4 PCl/G 0.171 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Neptunium-237 R

ASTM C 1476-00 Modified

-0.0315 0.271 13994-20-2 PCl/G u 0.629 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Plutonium-238 R

DOE EML HASL-300, Pu-11-RC Modified 0.0599 0.0706 13981-16-3 PCl/G 0.0764 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Plutonium-239/240 R

DOE EML HASL-300, Pu-11-RC Modified 0.0325 0.0647 OER-100-70 PCl/G 0.105 1.00 1.00 40.7 BGA2.1.5 SAMPLE 1/2015/2016 388119 Plutonium-241 R

DOE EML HASL-300, Pu-11-RC Modified

-4.32 6.45 14119-32-5 PCl/G u 11.4 15.0 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 6.75 1.12 13966-00-2 PCl/G 0.714 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 6.88 1.22 13966-00-2 PCl/G 0.897 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.161 0.517 14331-85-2 PCl/G u 0.962 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0165 0.551 14331-85-2 PCl/G u 0.997 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.469 0.170 13982-63"3 PCl/G 0.138 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.526 0.153 13982-63-3 PCl/G 0.153 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.753 0.257 15262-20-1 PCl/G 0.279 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.593 0.293 15262-20-1 PCl/G 0.244 1.00 40.7 BGA2.1.5 SAMPLE 42375 388119 Strontium~90 R

EPA 905.0 Modified/DOE RP501 Rev. 1 Modified

-0.686 0.653 10098-97-2 PCl/G u 1.41 2.00 1.00 40.7 BGA2.1.5 SAMPLE 42388 388119 Technetium-99 R

DOE EML HASL-300, Tc-02-RC Modified 0.839 2.33 14133-76-7 PCl/G u 3.98 5.00 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.210 0.0766 14913-50-9 PCl/G 0.0788 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.225 0.0615 14913-50-9 PCl/G 0.0782 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Thorium-228 R

DOE EML HASL-300, Th-01-RC Modified 0.517 0.497 14274-82-9 PCl/G 0.600 1.cio 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Thorium-229 R

DOE EML HASL-300, Th-01-RC Modified 0.0661 0.248 15594-54-4 PCl/G u 0.417 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Thorium-230 R

DOE EML HASL-300, Th-01-RC Modified 0.867 0.565 14269-63-7 PCl/G 0.260 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Thorium-232 R

DOE EML HASL-300, Th-01-RC Modified 0.370 0.423 7440-29-1 PCl/G 0.528 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42374 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0453 0.0905 PCl/G u 0.149 1.00 40.7 BGA2.1.5 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0714 0.0922 PCl/G u 0.172 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Tritium R

EPA 906.0 Modified

-0.806 3.02 10028-17-8 PCl/G u 5.28 6.00 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Uranium-232 R

DOE EML HASL-300, U-02-RC Modified

-0.0535 0.122 14158~29-3 PCl/G u 0.332 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Uranium-233/234 R

DOE EML HASL-300, U-02-RC Modified 0.591 0.273 13968-55-3/139 PCl/G 0.0934 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Uranium-235/236 R

DOE EML HASL-300, U-02-RC Modified 0.0624 0.107 15117-96-1/139. PCl/G 0.0936 1.00 1.00 40.7 BGA2.1.5 SAMPLE 42381 388119 Uranium-238 R

DOE EML HASL-300, U-02-RC Modified 1.02 0.356 7440-61-1 PCl/G 0.149 1.00 1.00 40.7 BGA2.1.5 DUP 42375 388092 Strontium-90 R

EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 0.240 0.795 10098-97-2 PCl/G u 1.43 2.00 1.00 40.7 BGA2.1.5 DUP 42375 388119 Strontium-90 R

EPA 905.0 Modified/DOE RP501 Rev. 1 Modified 0.240 0.795 10098-97-2 PCl/G u 1.43 2.00 1.00 40.7 J

Backgroun ackgrouna Sample No. Type.

Analyzed "SDG Parameter Fraction Method Result.

Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA2.1.6 SAMPLE 42380 388121 Actinium-227 R

EPA 901.1

-11.7 28.8 14952-40-0 PCl/L u

49.4 1.00 100 BGA2.1.6 SAMPLE 42375 388121 ALPHA R

EPA 900.0/SW846 9310

-1.01 1.07 12587-46-1 PCl/L u

2.98 5.00 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Antimony-125 R

EPA 901.1 6.50 9.82 14234-35-6 PCl/L u

18.1 1.00 100 BGA2.1.6 SAMPLE 42375 388121 BETA R

EPA 900.0/SW846 9310

-2.69 2.41 12587-47-2 PCl/L u

4.84 5.00 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Bismuth-212 R

EPA 901.1 43.0 51.7 14913-49-6 PCl/L u

102 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Bismuth-214 R

EPA 901.1 0.00 14.7 14733-03-0 PCl/L UI 15.9 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Cesium-137 R

EPA 901.1

-0.165 3.50 10045-97-3 PCl/L u

6.42 10.0 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Cobalt-60 R

EPA 901.1

-1.18 3.60 10198-40-0 PCl/L u

6.09 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Europium-154 R

EPA 901.1

-0.889 10.4 15585-10-1 PCl/L u

19.7 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Lead-212 R

EPA 901.1 6.25 13.6 15092-94-1 PCl/L u

13.1 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Lead-214 R

EPA 901.1 5.16 10.4 15067-28-4 PCl/L u

17.3 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Potassium-40 R

EPA 901.1 19.7 64.9 13966-00-2 PCl/L u

65.0 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Protactinium-231 R

EPA 901.1

-15.1 54.0 14331-85-2 PCl/L u

92.8 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Radium-228 R

EPA 901.1

-0.994 16.1 15262-20-1 PCl/L u

27.9 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Thallium-208 R

EPA 901.1 2.84 4.56 14913-50-9 PCl/L u

7.67 1.00 100 BGA2.1.6 SAMPLE 42380 388121 Tin-126 R

EPA 901.1

-0.907 8.81 PCl/L u

15.9 1.00 100 BGA2.2.1 SAMPLE 42374 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.281 0.398 14952-40-0 PCl/G u 0.756 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.112 0.409 14952-40-0 PCl/G u 0.710 1.00 38.7 BGA2.2.1 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 13.0 3.73 12587-46-1 PCl/G 3.89 4.00 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0738 0.146 14234-35-6 PCl/G u 0.259 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0293 0.152 14234-35-6 PCl/G u 0.270 1.00 38.7 BGA2.2.1 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 29.4 3.35 12587-47-2.

PCl/G 3.64 10.0 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.998 1.00 14913-49-6 PCl/G 1.49 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.598 1.34 14913-49-6 PCl/G u 1.89 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.892 0.217 14733-03-0 PCl/G 0.242 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.871 0.248 14733-03-0 PCl/G 0.203 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.323 0.120 10045-97-3 PCl/G 0.112 0.100 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.292 0.114 10045-97-3 PCl/G 0.102 0.100 1.00*

38.7 BGA2.2.1 SAMPLE 42374 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0312 0.0465 10198-40-0 PCl/G u 0.107 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0223 0.0647 10198-40-0 PCl/G u 0.134 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0121 0.216 15585-10-1 PCl/G u 0.407 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0458 0.198 15585-10-1 PCl/G u 0.397 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.02 0.156 15092-94-1 PCl/G 0.167 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.902 0.195 15092-94-1 PCl/G 0.217 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.983 0.250 15067-28-4 PCl/G 0.202 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.839 0.252 15067-28-4 PCl/G 0.187 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 17.4 2.13 13966-00-2 PCl/G 1.10 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 20.1 2.44 13966-00-2 PCl/G 1.18 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.380 0.777 14331-85-2 PCl/G u 1.40 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.946 14331-85-2 PCl/G UI 1.33 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.892 0.217 13982-63-3 PCl/G 0.242 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.871 0.248 13982-63-3 PCl/G 0.203 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.888 0.362 15262-20-1 PCl/G 0.430 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.05 0.326 15262-20-1 PCl/G 0.319 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.362 0.103 14913-50-9 PCl/G 0.0953 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.395 0.115 14913-50-9 PCl/G 0.117 1.00 38.7 BGA2.2.1 SAMPLE 42374 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.136 PCl/G UI 0.249 1.00 38.7 BGA2.2.1 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.027 0.159 PCl/G u 0.253 1.00 38.7 BGA2.2.2 SAMPLE 42374 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0141 0.380 14952-40-0 PCl/G u 0.693 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.247 0.309 14952-40-0 PCl/G u 0.600 1.00 37.3

Background ackground Sample No. Type Analyzed SDG

  • Parameter Fraction Method Result Uncertainty CAS*

Units Lab Qu MDL CRDL BGA2.2.2 SAMPLE 42380 388119 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 13.9 3.30 12587-46-1 PCl/G 3.07 4.00 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0256 0.135 14234-35-6 PCl/G u 0.250 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0877 0.124 14234-35-6 PCl/G u 0.206 1.00 37.3 8GA2.2.2 SAMPLE 42380 388119 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 17.4 2.86 12587-47-2 PCl/G 3.53 10.0 1.00 37.3 8GA2.2.2 SAMPLE 42374 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.24 1.36 14913-49-6 PCl/G 1.36 1.00 37.3 8GA2.2.2 SAMPLE 42389 388119 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.774 14913-49-6 PCl/G UI 1.45 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.750 0.214 14733-03-0 PCl/G 0.183 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.13 0.222 14733-03-0 PCl/G 0.170 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.192 0.0717 10045-97-3 PCl/G 0.103 0.100 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.181 0.0803 10045-97-3 PCl/G 0.0989 0.100 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0441 0.0537 10198-40-0 PCl/G u 0.115 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0148 0.0527 10198-40-0 PCl/G u 0.0945 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0371 0.240 15585-10-1 PCl/G u 0.449 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.108 0.185 15585-10-1 PCl/G u 0.263 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.25 0.165 15092-94-1 PCl/G 0.156 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.18 0.175 15092-94-1 PCl/G 0.169 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.904 0.266 15067-28-4 PCl/G 0.214 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.07 0.220 15067-28-4 PCl/G 0.190 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 19.5 2.12 13966-00-2 PCl/G 0.694 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 18.1 1.79 13966-00-2 PCl/G 0.730 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.760 14331-85-2 PCl/G UI 1.07 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.706 14331-85-2 PCl/G UI 1.18 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.750 0.214 13982-63-3 PCl/G 0.183 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.13 0.222 13982-63-3 PCl/G 0.170 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.34 0.421 15262-20-1 PCl/G 0.395 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.25 0.360 15262-20-1 PCl/G 0.318 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Thallium-208.

R DOE HASL 300, 4.5.2.3/Ga-01-R 0.461 0.104 14913-50-9 PCl/G 0.0941 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Thallium-208 R

DOE HASL 300, 4.5.2.3/Gia-01-R 0.412 0.0854 14913-50-9 PCl/G 0.083 1.00 37.3 BGA2.2.2 SAMPLE 42374 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.156 PCl/G UI 0.230 1.00 37.3 BGA2.2.2 SAMPLE 42389 388119 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.062 0.219 PCl/G u 0.205 1.00 37.3 BGA2.3.1 SAMPLE 42374 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00108 0.299 14952-40-0 PCl/G u 0.564 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0372 0.321 14952-40-0 PCl/G u 0.608 1.00 32.7 BGA2.3.1 SAMPLE 42381 388121 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 11.9 3.86 12587-46-1 PCl/G 3.97 4.00 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0187 0.112 14234-35-6 PCl/G.U 0.210 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0053 0.116 14234-35-6 PCl/G u 0.219 1.00 32.7 BGA2.3.1 SAMPLE 42381 388121 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 21.4 3.07 12587-47-2 PCl/G 2.91 10.0 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 2.03 0.748 14913-49-6 PCl/G 1.11 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.685 14913-49-6 PCl/G UI 1.37 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.876 0.161 14733-03-0 PCl/G 0.149 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.765 0.157 14733-03-0 PCl/G 0.152 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.359 0.0772 10045-97-3 PCl/G 0.0565 0.100 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.328 0.0933 10045-97-3 PCl/G 0.0929 0.100 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0388 0.0387 10198-40-0 PCl/G u 0.0589 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0242 0.0413 10198-40-0 PCl/G u 0.0913 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00175 0.134 15585-10-1 PCl/G u 0.263 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0709 0.160 15585-10-1 PCl/G u 0.287 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.984 0.137 15092-94-1 PCl/G 0.122 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.885 0.139 15092-94-1 PCl/G 0.138 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.09 0.202 15067-28-4 PCl/G 0.367 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.896 0.217 15067-28-4 PCl/G 0.178 1.00 32.7

Backgroun ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 8GA2.3.1 SAMPLE 42374 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.8 1.66 13966-00-2 PCl/G 0.861 1.00 32.7 8GA2.3.1 SAMPLE 42389 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.4 1.54 13966-00-2 PCl/G 0.649 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.699 14331-85-2 PCl/G UI 1.02 1.00 32.7 8GA2.3.1 SAMPLE 42389 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.338 0.673 14331-85-2 PCl/G u 1.20 1.00 32.7 8GA2.3.1 SAMPLE 42374 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.876 0.161 13982-63-3 PCl/G 0.149 1.00 32.7 8GA2.3.1 SAMPLE 42389 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.765 0.157 13982-63-3 PCl/G 0.152 1.00 32.7 8GA2.3.1 SAMPLE 42374 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.799 0.303 15262-20-1 PCl/G 0.292 1.00 32.7 8GA2.3.1 SAMPLE 42389 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.556 0.366 15262-20-1 PCl/G 0.357 1.00 32.7 8GA2.3.1 SAMPLE 42374 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.260 0.102 14913-50-9 PCl/G 0.0894 1.00 32.7 8GA2.3.1 SAMPLE 42389 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.295 0.106 14913-50-9 PCl/G 0.0872 1.00 32.7 BGA2.3.1 SAMPLE 42374 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.137 PCl/G UI 0.197 1.00 32.7 BGA2.3.1 SAMPLE 42389 388121 Tin-126 R

DOE HASL 300, 4.5.2:3/Ga-01-R 0.00 0.376

  • PCl/G UI 0.215 1.00 32.7 BGA2.3.2 SAMPLE 42374 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00517 0.245 14952-40-0 PCl/G u 0.466 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121

  • Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0775 0.263 14952-40-0 PCl/G u 0.476 1.00 27.5 BGA2.3.2 SAMPLE 42381 388121.

ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 5.20 2.84 12587-46-1 PCl/G.

3~85 4.00 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00452 0.0846 14234-35-6 PCl/G u 0.158 1.00 27.5 8GA2.3.2 SAMPLE 42389 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0243 0.0906 14234-35-6 PCl/G u 0.171 1.00 27.5 BGA2.3.2 SAMPLE 42381 388121 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 17.3 2.80 12587-47-2 PCl/G 2.62 10.0 1.00 27.5 8GA2.3.2 SAMPLE 42374 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.783 14913-49-6 PCl/G UI 0.901 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.835 0.657 14913-49-6 PCl/G 0.835 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.735 0.163 14733-03-0 PCl/G 0.130 1.00 27.5 BGA2.3.2 SAMPLE*

42389 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.918 0.156 14733-03-0 PCl/G 0.110 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.287 0.0663 10045-97-3 PCl/G 0.0767 0.100 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.217 0.0904 10045-97-3 PCl/G 0.0654 0.100 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0165 0.0366 10198-40-0 PCl/G u 0.0796 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00721 0.0411 10198-40-0 PCl/G u 0.0674 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0959 0.111 15585-10-1 PCl/G u 0.187 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0784 0.125 15585-10-1 PCl/G u 0.219 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.03 0.116 15092-94-1 PCl/G 0.0935 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.990 0.119 15092-94-1 PCl/G 0.107 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.05 0.176 15067-28-4 PCl/G 0.329 1.00 27.5 8GA2.3.2 SAMPLE 42389 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.08 0.187 15067-28-4 PCl/G 0.144 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.7 1.46 13966-00-2 PCl/G 0.644 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 14.0 1.42 13966-00-2 PCl/G 0.651 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.943 14331-85-2 PCl/G UI 0.930 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.570 14331-85-2 PCl/G UI 1.00 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.735 0.163 13982-63-3 PCl/G 0.130 1.00 27.5 8GA2.3.2 SAMPLE 42389 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.918 0.156 13982-63-3 PCl/G 0.110 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.02 0.263 15262-20-1 PCl/G 0.301 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.841 0.206 15262-20-1 PCl/G 0.177 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.225 0.0914 14913-50-9 PCl/G 0.0657 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R.

0.362 0.0776 14913-50-9 PCl/G 0.0586 1.00 27.5 BGA2.3.2 SAMPLE 42374 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0994 PCl/G UI 0.123 1.00 27.5 BGA2.3.2 SAMPLE 42389 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0595 0.0951 PCl/G u 0.144 1.00 27.5 BGA2.4.1 SAMPLE 42374 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0778 0.269 14952-40-0 PCl/G u 0.495 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00457 0.297 14952-40-0 PCl/G u 0.539 1.00 36.4 BGA2.4.1 SAMPLE 42381 388121 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 12.5 3.50 12587-46-1 PCl/G 3.90 4.00 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0537 0.121 14234-35-6 PCl/G u 0.244 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0689 0.111 14234-35-6 PCl/G u 0.220 1.00 36.4 BGA2.4.1 SAMPLE 42381 388121 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 23.6 3.45 12587-47-2 PCl/G 4.02 10.0 1.00 36.4

Background ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA2.4.1 SAMPLE 42374 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.702 14913-49-6 PCl/G UI 1.53 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.619 0.674 14913-49-6 PCl/G u 1.39 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.561 0.228 14733-03-0 PCl/G 0.223 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.851 0.159 14733-03-0 PCl/G 0.130 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.293 0.105 10045-97-3 PCl/G 0.102 0.100 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R

. 0.279 0.103 10045-97-3 PCl/G 0.0909 0.100 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00712 0.0619 10198-40-0 PCl/G u 0.126 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00501 0.0478 10198-40-0 PCl/G u 0.0922 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0744 0.163 15585-10-1 PCl/G u 0.298 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0601 0.161 15585-10-1 PCl/G u 0.324 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.776 0.115 15092-94-1 PCl/G 0.116 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.835 0.111 15092-94-1 PCl/G 0.108 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.912 0.221 15067-28-4 PCl/G 0.372 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.835 0.186 15067-28-4 PCl/G 0.146 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 13.0 1.87 13966-00-2 PCl/G 1.51 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 11.8 1.58 13966-00-2 PCl/G 0.444 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.876 14331-85-2 PCl/G UI 0.897 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.583 14331-85-2 PCl/G UI 0.963 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.561 0.228 13982-63-3 PCl/G 0.223 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.851 0.159 13982-63-3 PCl/G 0.130 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.716 0.331 15262-20-1 PCl/G 0.290 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.664 0.346 15262-20-1 PCl/G 0.255 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.208 0.0856 14913-50-9 PCl/G 0.106 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.275 0.085 14913-50-9 PCl/G 0.0737 1.00 36.4 BGA2.4.1 SAMPLE 42374 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0798 PCl/G UI 0.0849 1.00 36.4 BGA2.4.1 SAMPLE 42389 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.112 PCl/G UI 0.0927 1.00 36.4 BGA2.4.1 MSD 42380 388121 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 103 13.7 12587-46-1 4.48 4.00 1.00 36.4 BGA2.4.1 MSD 42380 388121 BETA R

EPA 900.0/SW846 931 O/SM 711 OB Modified 113 16.1 12587-47-2 5.29 10.0 1.00 36.4 BGA2.4.1 MS 42381 388121 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 97.5 13.9 12587-46-1 7.51 4.00 1.00 36.4 BGA2.4.1 MS 42381 388121 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 112 15.8 12587-47-2 5.57 10.0 1.00 36.4 BGA2.4.1 DUP 42381 388121 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 11.5 3.38 12587-46-1 PCl/G 3.94 4.00 1.00 36.4 BGA2.4.1 DUP 42381 388121 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 18.0 2.87 12587-47-2 PCl/G 3.28 10.0 1.00 36.4 BGA2.4.2 SAMPLE 42374 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.000969 0.269 14952-40-0 PCl/G u 0.511 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.167 0.247 14952-40-0 PCl/G u 0.478 1.00 31.9 BGA2.4.2 SAMPLE 42381 388121 ALPHA R

EPA 900.0/SW846 9310/SM 7110B Modified 10.0 3.36 12587-46-1 PCl/G 3.88 4.00 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.037 0.101 14234-35-6 PCl/G u 0.198 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0192 0.091 14234-35-6 PCl/G u 0.177 1.00 31.9 BGA2.4.2 SAMPLE 42381 388121 BETA R

EPA 900.0/SW846 9310/SM 7110B Modified 20.1 2.90 12587-47-2 PCl/G 2.83 10.0 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.827 14913-49-6 PCl/G UI 1.37 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.628 14913-49-6 PCl/G UI 1.02 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.671 0.168 14733-03-0 PCl/G 0.149 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.516 0.144 14733-03-0 PCl/G 0.123 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.291 0.0772 10045-97-3 PCl/G 0.0898 0.100 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.255 0.0656 10045-97-3 PCl/G 0.0605 0.100 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00111 0.0367 10198-40-0 PCl/G u 0.0757 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00105 0.0322 10198-40-0 PCl/G u 0.0629 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0484 0.120 15585-10-1 PCl/G u 0.227 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0762 0.105 15585-10-1 PCl/G u 0.179 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.725 0.154 15092-94-1 PCl/G 0.140 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.926 0.117 15092-94-1 PCl/G 0.0967 1.00 31.9

Backgroun ackground Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA2.4.2 SAMPLE 42374 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.905 0.189 15067-28-4 PCl/G 0.328 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.793 0.194 15067-28-4 PCl/G 0.129 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 11.9 1.49 13966-00-2 PCl/G 0.826 1.00 31.9

. BGA2.4.2 SAMPLE 42389 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 12.1 1.42 13966-00-2 PCl/G 0.588 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.274 0.601 14331-85-2 PCl/G u 1.05 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.803 14331-85-2 PCl/G UI 0.910 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.671 0.168 13982-63-3 PCl/G 0.149 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.516 0.144 13982-63-3 PCl/G 0.123 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.599 0.271 15262-20-1 PCl/G 0.326 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.723 0.246 15262-20-1 PCl/G 0.235 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.236 0.0736 14913-50-9 PCl/G 0.0718 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.193 0.0628 14913-50-9 PCl/G 0.0574 1.00 31.9 BGA2.4.2 SAMPLE 42374 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.011 0.109 PCl/G u 0.191 1.00 31.9 BGA2.4.2 SAMPLE 42389 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0836 PCl/G UI 0.141.

1.00 31.9 BGA2.4.2 DUP 42374 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0942 0.253 14952-40-0 PCl/G u 0.443 1.00 31.9 BGA2.4.2 DUP 42389 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.236 0.230 14952-40-0 PCl/G u 0.412 1.00 31.9 BGA2.4.2 DUP 42374 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0194 0.0892 14234-35-6 PCl/G u 0.160 1.00 31.9 BGA2.4.2 DUP 42389 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.017 0.086 14234-35-6 PCl/G u 0.160 1.00 31.9 BGA2.4.2 DUP 42374 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.742 14913-49-6 PCl/G UI 1.10 1.00 31.9 BGA2.4.2 DUP 42389 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.160 0.702 14913-49-6 PCl/G u 1.12 1.00 31.9 BGA2.4.2 DUP 42374 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.637 0.172 14733-03-0 PCl/G 0.115 1.00 31.9 BGA2.4.2

  • DUP 42389 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.643 0.162 14733-03-0 PCl/G 0.120 1.00 31.9 BGA2.4.2 DUP 42374 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.242 0.0599 10045-97-3 PCl/G 0.0402 0.100 1.00 31.9 BGA2.4.2 DUP 42389 388121

  • cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.253 0.0815 10045-97-3 PCl/G 0.0688 0.100 1.00 31.9 BGA2.4.2 DUP 42374 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0189 0.0333 10198-40-0 PCl/G u 0.0726 1.00 31.9 BGA2.4.2 DUP 42389 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0133 0.0377 10198-40-0 PCl/G u 0.0706 1.00 31.9 BGA2.4.2 DUP 42374 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0473 0.107 15585-10-1 PCl/G u 0.203 1.00 31.9 BGA2.4.2 DUP 42389 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0462 0.094 15585-10-1 PCl/G u 0.167 1.00 31.9 BGA2.4.2 DUP 42374 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.814 0.110 15092-94-1 PCl/G 0.0934 1.00 31.9 BGA2.4.2 DUP 42389 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.921 0.138 15092-94-1 PCl/G 0.105 1.00 31.9 BGA2.4.2 DUP 42374 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.742 0.150 15067-28-4 PCl/G 0.129 1.00 31.9 BGA2.4.2 DUP 42389 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.855 0.166 15067-28-4 PCl/G 0.143 1.00 31.9 BGA2.4.2 DUP 42374 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 13.3 1.41 13966-00-2 PCl/G 0.658 1.00 31.9 BGA2.4.2 DUP 42389 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 11.0 1.24 13966-00-2 PCl/G 0.580 1.00 31.9 BGA2.4.2 DUP 42374 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.878 14331-85-2 PCl/G UI 0.787 1.00 31.9 BGA2.4.2 DUP 42389 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.667 14331-85-2 PCl/G UI 0.800 1.00 31.9 BGA2.4.2 DUP 42374 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.637 0.172 13982-63-3 PCl/G 0.115 1.00 31.9 BGA2.4.2 DUP 42389 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.643 0.162 13982-63-3 PCl/G 0.120 1.00 31.9 BGA2.4.2 DUP 42374 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.832 0.246 15262-20-1 PCl/G 0.250 1.00 31.9 BGA2.4.2 DUP 42389 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.677 0.217 15262-20-1 PCl/G 0.220 1.00 31.9 BGA2.4.2 DUP 42374 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.243 0.070 14913-50-9 PCl/G 0.0528 1.00 31.9 BGA2.4.2 DUP 42389 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.229 0.0758 14913-50-9 PCl/G 0.0609 1.00 31.9 BGA2.4.2 DUP 42374 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.0791 PCl/G UI 0.106 1.00 31.9 BGA2.4.2 DUP 42389 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.136 PCl/G UI 0.140 1.00 31.9 BGA2.5.1 SAMPLE 42374 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.00301 0.316 14952-40-0 PCl/G u 0.590 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.150 0.286 14952-40-0 PCl/G u 0.555 1.00 44.7 BGA2.5.1 SAMPLE 42381 388121 ALPHA R

EPA 900.0/SW846 9310/SM 71108 Modified 8.75 3.18 12587-46-1 PCl/G 3.99 4.00 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00046 0.124 14234-35-6 PCl/G u 0.230 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.171 14234-35-6 PCl/G UI 0.236 1.00 44.7 BGA2.5.1 SAMPLE 42381 388121 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 22.9 2.90 12587-47-2 PCl/G 2.84 10.0 1.00 44.7

~

I Background ackground I

Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units Lab Qu MDL CRDL Dilution % Moist1 BGA2.5.1 SAMPLE 42374 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.882 14913-49-6 PCl/G UI 1.75 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.796 14913-49-6 PCl/G UI 1.56 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.726 0.178 14733-03-0 PCl/G 0.166 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.674 0.176 14733-03-0 PCl/G 0.155 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.372 0.122 10045-97-3 PCl/G 0.0885 0.100 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.427 0.0877 10045-97-3 PCl/G 0.0836 0.100 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0499 0.0474 10198-40-0 PCl/G u 0.073 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0092 0.0425 10198-40-0 PCl/G u 0.0874 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.169 0.167 15585-10-1 PCl/G u 0.267 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0872 0.118 15585-10-1 PCl/G u 0.262 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.875 0.180 15092-94-1 PCl/G 0.196 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.980 0.125 15092-94-1 PCl/G 0.113 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.01 0.213 15067-28-4 PCl/G 0.200 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.988 0.205 15067-28-4 PCl/G 0.151 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 13.8 1.76 13966-00-2 PCl/G 0.715 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 15.5 1.69 13966-00-2 PCl/G 0.728 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.557 0.674 14331-85-2 PCl/G u 1.27 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.520 0.655 14331-85-2 PCl/G u 1.15 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.726 0.178 13982-63-3 PCl/G 0.166 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.674 0.176 13982-63-3 PCl/G 0.155 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.941 0.384 15262-20-1 PCl/G 0.369 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.989 0.262 15262-20-1 PCl/G 0.299 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.312 0.0932 14913-50-9 PCl/G 0.0858 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.333 0.0805 14913-50-9 PCl/G 0.082 1.00 44.7 BGA2.5.1 SAMPLE 42374 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0536 0.183 PCl/G u 0.252 1.00 44.7 BGA2.5.1 SAMPLE 42389 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.127 PCl/G UI 0.142 1.00 44.7 BGA2.5.2 SAMPLE 42374 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.186 0.310 14952-40-0 PCl/G u 0.542 1.00 30.5 BGA2.5.2 SAMPLE.

42389 388121 Actinium-227 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.493 0.387 14952-40-0 PCl/G u 0.597 1.00 30.5 BGA2.5.2 SAMPLE 42381 388121 ALPHA R

EPA 900.0/SW846 931 O/SM 711 OB Modified 12.9 4.02 12587-46-1 PCl/G 3.92 4.00 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0366 0.141 14234-35-6 PCl/G u 0.230 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Antimony-125 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.109 0.155 14234-35-6 PCl/G u 0.269 1.00 30.5 BGA2.5.2 SAMPLE 42381 388121 BETA R

EPA 900.0/SW846 9310/SM 71108 Modified 25.2 3.30 12587-47-2 PCl/G 2.97 10.0 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.811 14913-49-6 PCl/G UI 1.67 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Bismuth-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.848 1.16 14913-49-6 PCl/G u 1.99 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.849 0.191 14733-03-0 PCl/G 0.179 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Bismuth-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.876 0.282 14733-03-0 PCl/G 0.192 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.114 0.0534 10045-97-3 PCl/G 0.0927 0.100 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Cesium-137 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.134 0.0807 10045-97-3 PCl/G 0.105 0.100 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00308 0.0518 10198-40-0 PCl/G u 0.102 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Cobalt-60 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0205 0.0643 10198-40-0 PCl/G u 0.140 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R

-0.0672 0.166 15585-10-1 PCl/G u 0.301 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Europium-154 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0568 0.152 15585-10-1 PCl/G u 0.347 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.12 0.142 15092-94-1 PCl/G 0.132 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Lead-212 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.15 0.162 15092-94-1 PCl/G 0.155 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.940 0.242 15067-28-4 PCl/G 0.170 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Lead-214 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.15 0.276 15067-28-4 PCl/G 0.224 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 17.6 1.80 13966-00-2 PCl/G 0.741 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Potassium-40 R

DOE HASL 300, 4.5.2.3/Ga-01-R 19.5 2.57 13966-00-2 PCl/G 1.10 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.968 14331-85-2 PCl/G UI 1.04 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Protactinium-231 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 1.16 14331-85-2 PCl/G UI 1.23 1.00 30.5

Backgroun ackground, Sample No. Type Analyzed SDG Parameter Fraction Method Result Uncertainty CAS Units

  • Lab Qu MDL CRDL Dilution % Moist1 BGA2.5.2 SAMPLE 42374 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.849 0.191 13982-63-3 PCl/G 0.179 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Radium-226 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.876 0.282 13982-63-3 PCl/G 0.192 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.937 0.362 15262-20-1 PCl/G 0.283 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Radium-228 R

DOE HASL 300, 4.5.2.3/Ga-01-R 1.10 0.366 15262-20-1 PCl/G 0.454 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.354 0.0785 14913-50-9 PCl/G 0.0832 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Thallium-208 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.312 0.137 14913-50-9 PCl/G 0.106 1.00 30.5 BGA2.5.2 SAMPLE 42374 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.00 0.156 PCl/G UI 0.215 1.00 30.5 BGA2.5.2 SAMPLE 42389 388121 Tin-126 R

DOE HASL 300, 4.5.2.3/Ga-01-R 0.0749 0.204 PCl/G u 0.222 1.00 30.5