MONTHYEARML16041A2282016-02-11011 February 2016 Interim Staff Response to Reevaluated Flood Hazards Submitted in Response to 10 CFR 50.54(f) Information Request - Flood-Causing Mechanism Reevaluation Project stage: Other ML16131A5822016-06-0909 June 2016 NRC Report for the Audit of Luminant Generation Company, Llc'S Flood Hazard Reevaluation Report Submittal Relating to the Near-Term Task Force Recommendation 2.1-Flooding for Comanche Peak Nuclear Power Plant, Units 1 and 2 Project stage: Other CP-201700033, Mitigating Strategies Assessment Flood Report, NEI 12-06, Appendix G, Revision 2, G.4.1 Path2017-02-0909 February 2017 Mitigating Strategies Assessment Flood Report, NEI 12-06, Appendix G, Revision 2, G.4.1 Path Project stage: Other ML17067A1662017-06-13013 June 2017 Staff Assessment of Response to 10 CFR 50.54(f) Information Request - Flood-Causing Mechanism Reevaluation Project stage: Acceptance Review 2016-06-09
[Table View] |
|
---|
Category:Audit Report
MONTHYEARML24024A2102024-01-29029 January 2024 Summary of Regulatory Audit Regarding a License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems, and Components for Nuclear Power Reactors ML23172A1472023-08-0909 August 2023 Breakout Questions - Aging Management Audit - Comanche Peak Units 1 and 2 - License Renewal Application ML23172A1462023-08-0909 August 2023 Aging Management Audit Report - Comanche Peak Units 1 and 2 - License Renewal Application ML22152A0412022-06-10010 June 2022 Summary of Regulatory Audit License Amendment Request to Revise TS to Adopt TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times RITSTF Initiative 4b ML16131A5822016-06-0909 June 2016 NRC Report for the Audit of Luminant Generation Company, Llc'S Flood Hazard Reevaluation Report Submittal Relating to the Near-Term Task Force Recommendation 2.1-Flooding for Comanche Peak Nuclear Power Plant, Units 1 and 2 ML15180A2612015-08-0505 August 2015 Report for the Audit Regarding Implementation of Mitigating Strategies Related to Order EA-12-049 ML14213A0332014-09-0202 September 2014 Audit of the Licensee'S Management of Regulatory Commitments, Audit Performed July 15-17, 2014 ML13225A5752013-12-19019 December 2013 Interim Staff Evaluation Relating to Overall Integrated Plan in Response to Order EA-12-049 - Mitigation Strategies ML13296A5432013-11-22022 November 2013 Audit Report for 7/9-11/2013 Audit Seismic Walkdowns to Support Implementation of Near-Term Task Force Recommendation 2.3 Related to Fukushima Dai-Ichi Nuclear Power Plant Accident ML1124405142011-09-23023 September 2011 Audit of the Licensee'S Management of Regulatory Commitments, Audit Performed August 16-17, 2011 ML0819706662008-07-31031 July 2008 Audit of the Licensee'S Regulatory Commitment Management Program, Audit Performed 6/9/2008 to 6/11/2008 ML0434203082004-12-16016 December 2004 Regulatory Commitments Management Program Audit Report 2024-01-29
[Table view] Category:Letter
MONTHYEARCP-202400030, License Renewal Application Revision 0 - Supplement 3, Revision 12024-01-31031 January 2024 License Renewal Application Revision 0 - Supplement 3, Revision 1 IR 05000445/20230042024-01-29029 January 2024 Integrated Inspection Report 05000445/2023004 and 05000446/2023004 CP-202400034, (CPNPP) - Core Operating Limits Report (Colr), Unit 2 Cycle 21, (ERX-23-001, Revision 1)2024-01-29029 January 2024 (CPNPP) - Core Operating Limits Report (Colr), Unit 2 Cycle 21, (ERX-23-001, Revision 1) ML24024A2102024-01-29029 January 2024 Summary of Regulatory Audit Regarding a License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems, and Components for Nuclear Power Reactors ML24025A0052024-01-25025 January 2024 Review of the Spring 2023 Steam Generator Tube Inspection Report ML24023A0242024-01-24024 January 2024 Correction to Amendment Nos. 185 and 185 Regarding Implementation of Full Spectrum Loss-of-Coolant Accident Methodology ML24018A1072024-01-18018 January 2024 Notification of Commercial Grade Dedication Inspection (05000445/2024012 and 05000446/2024012) and Request for Information ML23159A2082023-12-20020 December 2023 Request for Withholding Information from Public Disclosure ML23319A3872023-12-20020 December 2023 Issuance of Amendment Nos. 185 and 185 Regarding Implementation of Full Spectrum Loss-of-Coolant Accident (Fsloca) Methodology ML23348A2392023-12-19019 December 2023 Nonacceptance of License Amendment Request to Relocate Technical Specification 3.9.3, Nuclear Instrumentation, to the Technical Requirements Manual CP-202300575, (Cpnpp), License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors Supplement 22023-12-13013 December 2023 (Cpnpp), License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors Supplement 2 ML23333A0872023-12-13013 December 2023 Transmittal of Dam Safety Inspection Report - Public CP-202300566, (Cpnpp), Special Report 1-SR-23-001-00, Inoperable Post Accident Monitoring Instrumentation2023-12-12012 December 2023 (Cpnpp), Special Report 1-SR-23-001-00, Inoperable Post Accident Monitoring Instrumentation CP-202300494, License Renewal Application Revision 0, Supplement 32023-12-0606 December 2023 License Renewal Application Revision 0, Supplement 3 ML23313A0732023-12-0606 December 2023 Issuance of Amendment Nos. 184 and 184 Regarding Revision to Technical Specifications to Implement WCAP-17661-P-A, Rev. 1, Improved Roac and CAOC Fq Surveillance Technical Specifications ML23291A4382023-11-30030 November 2023 Notice of Availability of the Draft Plant-Specific Supplement 60, to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants Regarding Comanche Peak Nuclear Power Plant, Unit Numbers 1 and 2, License Renewal Applica ML23325A0182023-11-30030 November 2023 Schedule Revision for the License Renewal Application Review IR 05000445/20234022023-11-30030 November 2023 NRC Security Inspection Report 05000445/2023402 and 05000446/2023402 CP-202300349, License Amendment Request (Lar) 23-004 Technical Specifications (TS) 3.9.3, Nuclear Instrumentation2023-11-20020 November 2023 License Amendment Request (Lar) 23-004 Technical Specifications (TS) 3.9.3, Nuclear Instrumentation ML23308A0032023-11-17017 November 2023 Letter to R. Nelson, Executive Director; Achp; Re., Comanche Peak Draft Environmental Impact Statement ML23308A0022023-11-17017 November 2023 Letter to M. Wolfe, Executive Director; Shpo; Re., Comanche Peak Draft Environmental Impact Statement ML23317A3002023-11-13013 November 2023 Letter to R. Sylestine, Chairman, Alabama-Coushatta Tribe of Texas Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2972023-11-13013 November 2023 Letter to R. Martin, President, Tonkawa Tribe of Oklahoma Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2872023-11-13013 November 2023 Letter to J. Garza, Chairman, Kickapoo Traditional Tribe of Texas Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2832023-11-13013 November 2023 Letter to D. Dotson, President, Delaware Nation Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2852023-11-13013 November 2023 Letter to E. Martinez, President, Mescalero Apache Tribe Regarding Comanche Peak Draft Environmental Impact Statement ML23306A0302023-11-13013 November 2023 Letter to J. Cernek, Chairman; Coushatta Tribe of Louisiana Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2902023-11-13013 November 2023 Letter to M. Pierite, Chairman, Tunica Biloxi Tribe of Louisiana Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2982023-11-13013 November 2023 Letter to R. Morrow, Town King, Thlopthlocco Tribal Town Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2842023-11-13013 November 2023 Letter to D. Kaskaske, Chairman, Kickapoo Tribe of Oklahoma Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2822023-11-13013 November 2023 Letter to D. Cooper, Chairman, Apache Tribe of Oklahoma Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2962023-11-13013 November 2023 Letter to M. Woommavovah, Chairman, Comanche Nation Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2812023-11-13013 November 2023 Letter to C. Hoskin, Principal Chief, Cherokee Nation; Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2862023-11-13013 November 2023 Letter to J. Bunch, Chief, United Keetoowah Band of Cherokee Indians Regarding Comanche Peak Draft Environmental Impact Statement ML23317A3032023-11-13013 November 2023 Letter to W. Yargee, Chief, Alabama-Quassarte Tribal Town Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2882023-11-13013 November 2023 Letter to L. Johnson, Chief, Seminole Nation of Oklahoma Regarding Comanche Peak Draft Environmental Impact Statement ML23317A3012023-11-13013 November 2023 Letter to S. Yahola, Mekko, Kialegee Tribal Town Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2792023-11-13013 November 2023 Letter to B. Gonzalez, Chairman, Caddo Nation Regarding Comanche Peak Draft Environmental Impact Statement ML23317A3022023-11-13013 November 2023 Letter to T. Parton, President, Wichita and Affiliated Tribes Regarding Comanche Peak Draft Environmental Impact Statement ML23317A2892023-11-13013 November 2023 Letter to L. Spottedbird, Chairman, Kiowa Indian Tribe Regarding Comanche Peak Draft Environmental Impact Statement ML23311A2082023-11-0909 November 2023 Reassignment of U.S. Nuclear Regulatory Commission Branch Chief in the Division of Operating Reactor Licensing for Plant Licensing Branch IV ML23360A6312023-10-26026 October 2023 FEMA, Submittal of Radiological Emergency Preparedness Final Report for the Comanche Peak Nuclear Power Plant Medical Services Drill Evaluated on August 23, 2023 CP-202300416, Supplemental Information to Facilitate Acceptance of Licensee Amendment Request 23-002, Application Regarding GDC-5 Shared System Requirements2023-10-12012 October 2023 Supplemental Information to Facilitate Acceptance of Licensee Amendment Request 23-002, Application Regarding GDC-5 Shared System Requirements CP-202300432, Response to Request for Additional Information Regarding the Safety Review of the License Renewal Application - Set 42023-10-0404 October 2023 Response to Request for Additional Information Regarding the Safety Review of the License Renewal Application - Set 4 ML23237B4222023-09-28028 September 2023 Energy Harbor Nuclear Corp. - Vistra Operations Company LLC - Letter Regarding Order Approving Transfer of Licenses and Draft Conforming License Amendments ML23263A0242023-09-21021 September 2023 Revision of Schedule for the Environmental Review of the Comanche Peak Nuclear Power Plant Units 1 and 2 License Renewal Application 2024-01-31
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 June 9, 2016 Mr. Ken J. Peters Senior Vice President and Chief Nuclear Officer Attention: Regulatory Affairs Luminant Generation Company, LLC P.O. Box 1002 Glen Rose , TX 76043
SUBJECT:
NUCLEAR REGULATORY COMMISSION REPORT FOR THE AUDIT OF LUMINANT GENERATION COMPANY, LLC.'S FLOOD HAZARD REEVALUATION REPORT SUBMITTAL RELATING TO THE NEAR-TERM TASK FORCE RECOMMENDATION 2.1-FLOODING FOR COMANCHE PEAK NUCLEAR POWER PLANT, UNITS 1 AND 2 (CAC NOS. MF1099 AND MF1100)
Dear Mr. Peters:
By letter dated June 11 , 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML15148A677), the U.S. Nuclear Regulatory Commission (NRC) informed you of the staff's plan to conduct a regulatory audit of the Luminant Generation Company, LLC's (Luminant, the licensee) Flood Hazard Reevaluation Report (FHRR) submittal related to the Near-Term Task Force Recommendation 2.1-Flooding for Comanche Peak Nuclear Power Plant, Units 1 and 2 (Comanche Peak) . The audit was intended to support the NRC staff review of the licensee's FHRR and the subsequent issuance of a staff assessment.
The NRC conducted the audit and associated follow-up calls on July 6, 2015, December 10, 2015, and January 20, 2016. The audits were performed consistent with NRC Office of Nuclear Reactor Regulation , Office Instruction LIC-111 , "Regulatory Audits ," dated December 29, 2008, (ADAMS Accession No. ML082900195). The purpose of this letter is to provide you with the final audit report which summarizes and documents the NRC's regulatory audit of the licensee's FHRR submittal.
K. Peters If you have any questions, please contact me at (301) 415-2915 or by e-mail at Victor.Hall@nrc.gov.
Sincerely, V:x 2- ~
Victor Hall, Senior Project Manager Office of Nuclear Reactor Regulation Japan Lessons-Learned Division Hazards Management Branch Docket Nos.: 50-445 and 50-446
Enclosure:
Audit Report cc w/encl : Distribution via Listserv
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 AUDIT REPORT BY THE OFFICE OF NUCLEAR REACTOR REGULATION FOR THE AUDIT OF LUMINANT GENERATION COMPANY, LLC'S FLOOD HAZARD REEVALUATION REPORT SUBMITTAL RELATING TO THE NEAR-TERM TASK FORCE RECOMMENDATION 2.1-FLOODING FOR COMANCHE PEAK NUCLEAR POWER PLANT, UNITS 1 AND 2 DOCKET NOS. 50-445 AND 50-446 BACKGROUND AND AUDIT BASIS By letter dated March 12, 2012, the U.S. Nuclear Regulatory Commission (NRC) issued a request for information to all power reactor licensees and holders of construction permits in active or deferred status, pursuant to Title 10 of the Code of Federal Regulations (10 CFR),
Section 50.54(f) "Conditions of license" (hereafter referred to as the "50.54(f) letter). The request was issued in connection with implementing lessons-learned from the 2011 accident at the Fukushima Dai-ichi nuclear power plant, as documented in The Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident. Recommendation 2.1 in that document recommended that the NRC staff issue orders to all licensees to reevaluate seismic and flooding for their sites against current NRC requirements and guidance. Subsequent Staff Requirements Memoranda associated with Commission Papers SECY 11-0124 and SECY-11-0137 , instructed the NRC staff to issue requests for information to licensees pursuant to 10 CFR 50.54(f).
By letter dated March 12, 2013, Luminant Generation Company, LLC (Luminant, the licensee) submitted its Flood Hazard Reevaluation Report (FHRR) for Comanche Peak Nuclear Power Plant, Units 1 and 2 (Comanche Peak) (Agencywide Documents Access and Management System Accession No. ML13074A058) . The NRC has reviewed the submittal and has completed a regulatory audit of the licensee to better understand the development of the subm ittal , identify any similarities with past work completed and ultimately aid in its review of the licensees' FHRR. This audit summary was completed in accordance with the guidance set forth in NRC Office of Nuclear Reactor Regulation , Office Instruction LIC-111 , "Regulatory Audits ,"
dated December 29, 2008 (ADAMS Accession No. ML082900195).
AUDIT LOCATION AND DATES The audit was completed at NRC Headquarters in Rockville , MD, on July 6, 2015, by document review via the licensee's established electronic reading room and by teleconferences on December 10, 2015, and January 20, 2016.
Enclosure
DOCUMENTS AUDITED The documents reviewed by the NRC staff were located in an electronic reading room during the NRC staff's review. Documents used by the NRC staff to support the technical analysis will be referenced in the staff assessment.
AUDIT TEAM The NRC audit team , and audit partipants were as follows:
AUDIT TEAM July 6, 2015 December 10, 2015 January 20, 2016 NRC Staff Victor Hall, Team Leader, NRR x x x Andy Campbell, NRO x x Mohamed Shams, NRR x x Chris Cook, NRO x Aida Rivera-Varona , NRO x Nebiyu Tiruneh , NRO x x Laura Quinn-Willingham , NRO x Oak Ridge National Laboratories Contractors Scott DeNeale (via telecon) x x David Watson (via telecon) x x AUDIT TEAM July 6, 2015 December 10, 2015 January 20, 2016 Luminant Tom McCool x x x Carl Corbin x x x Mike Osterman x x Norman Terrel x x x Tim Hope x Westinghouse Mark Moenssens x x x Richard Giachetti x Rizzo Associates Ahmed "Jemie" Dababneh x x Jeffrey Oskamp x Mark Schwartz x Tom Edwards x
AUDIT ACTIVITIES The audit focused on gaining a better understanding of the local intense precipitation modeling results for the Comanche Peak FHRR. Luminant, in coordination with Westinghouse and Rizzo Associates Inc. made presentations and shared revised modeling results. The audit included discussions regarding the licensees's use of Hydrologic Engineering Center (HEC) River Analysis System (RAS) modeling, and the licensee's quasi 2-D approach in HEC-RAS. During the discussions, the staff and licensee discussed the use of water elevation 810.6' as the local intense precipitation flood level for all the power block structures systems and components as a reasonable estimate.
EXIT MEETING/BRIEFING By letter dated , February 11 , 2016, the NRC staff issued a summary of the reevaluated flood-causing mechanisms (ADAMS Accession No. ML16041A228). That letter concluded that the licensee's reevaluated flooding hazard information is a suitable input for the mitigating strategies assessment as well as assessments associated with Near-Term Task Force Recommendation 2.1 "Flooding ," thus closing out the discussion of the technical topics described above.
K. Peters If you have any questions, please contact me at (301) 415-2915 or by e-mail at Victor.Hall@nrc.gov.
Sincerely, IRA/
Victor Hall, Senior Project Manager Office of Nuclear Reactor Regulation Japan Lessons-Learned Division Hazards Management Branch Docket Nos. : 50-445 and 50-446
Enclosure:
Audit Report cc w/encl : Distribution via Listserv DISTRIBUTION :
PUBLIC JLD R/F RidsNRRJLD Resource VHall , NRR LQuinn-Willingham , NRO RidsNroDsea Resource RidsNrrDorllpl4-1 Resource RidsNrrDorl Resource RidsNrrComanchePeak Resource RidsRgn4MailCenter Resource RidsNrrLASLent RidsOgcMailCenter Resource RidsOpaMail Resource RidsAcrsAcnw_MailCtr Resource CCook , NRO ARivera-Varona , NRO KErwin, NRO ACampbell , NRO MWillingham , NRO RRivera-Lugo , NRO BHarvey, NRO MShams, NRR NTiruneh, NRO ADAMS Accession No.: ML16131A582 *via email OFFICE NRR/JLD/JHMB/PM NRR/JLD/JHMB/LA NRO/DSENRHM2!TR* NRO/DSENRHM2/BC NAME VHall Slent NTiruneh ARivera-Varona DATE 05/09/2016 05/10/2016 06/01/2016 06/07/2016 OFFICE NRR/JLD/JHMB/BC NRR/JLD/JHMB/PM NAME MShams VHall DATE 05/15/2016 06/09/2016 OFFICAL RECORD COPY