December 2014 River Bend Station NRC Initial License Examination Reactor Operator 1
QUESTION 1 Rev 1 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295001 AK2.02 IR 3.2 Knowledge of the interrelations between PARTIAL OR COMPLETE LOSS OF FORCED CORE FLOW CIRCULATION and the following: Nuclear boiler instrumentation.
Proposed Question:
The plant was operating at 100% power when a transient occurs resulting in the following conditions:
RPV level 35 inches and stable Reactor Power is 73% and stable Total Core Flow is 51.5 x 106 lbm/hr and stable The cause of this transient was the receipt of a signal from the ___.
A. ATWS/ARI logic.
B. EOC-RPT logic.
C. Recirc Flow Control Valve Runback logic D. Recirc Pump Cavitation Interlock Circuitry Proposed Answer:
C Explanation A. The ATWS logic uses high RPV pressure and/or low RPV water level to trip the Recirc pumps to OFF.
Core flow would indicate the Recirc pumps are still running.
B. This logic uses Turbine stop valve/first stage pressure to trip the Recirc pumps to SLOW, however, Slow speed Recirc Pumps would have altered Reactor power and core flow to less than given in stem.
C. Correct - The Reactor power and the Total Core Flow are consistent with a FCV Runback.
D. The cavitation interlocks will trip the Recirc pumps to slow speed; Reactor power and core flow are inconsistent with Recirc pumps in slow speed.
Technical Reference(s):
R-STM-0053, Rev 13, p. 40 of 76 AOP-0024, Thermal Hydraulic Stability, Rev 25 Attachment 1 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0053, Obj 2 Question Source:
Bank #
October 2000 NRC exam #26 Question History:
Last NRC Exam October 2000 Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 2
QUESTION 2 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295004 AK1.04 IR 2.8 Knowledge of the operational implications of the following concepts as they apply to PARTIAL OR COMPLETE LOSS OF DC POWER : Effect of battery discharge rate on capacity.
Proposed Question:
A 125 VDC bus has experienced a trip of its battery charger supply breaker. Efforts to restore the battery charger to service have been unsuccessful. Assuming battery loading remains un-changed; predict the change in bus voltage under these conditions.
Voltage will _____.
A. decrease sharply and then level off.
B. decrease in a linear fashion.
C. slowly lower and then drop sharply.
D. stair step down as individual cells are depleted.
Proposed Answer:
C Explanation A. See C B. See C C. Correct - Battery voltage will decrease slowly then drop sharply as battery voltage reversal occurs as seen in SER 3-99.
D. See C Technical Reference(s):
RPPT-STM-0305-ILO Rev 2, Slide 95; SER 3-99 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0305, Obj 8 Question Source:
Bank #
March 2014 NRC exam #48 Question History:
Last NRC Exam March 2014 Exam #48 Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.8 Comments: Appeared on one of last 2 NRC exams (1 of 2)
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 3
QUESTION 3 Rev 1 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295005 AK2.07 IR 3.6 Knowledge of the interrelations between MAIN TURBINE GENERATOR TRIP and the following: Reactor pressure control Proposed Question:
The plant is performing a Startup, operating at 30% power when a break occurs in the EHC Hydraulic Supply line to the #2 Main Stop Valve Actuator. The Standby EHC pump starts on low pressure and the main turbine trips.
In this transient, with no operator action, the Turbine Bypass Valves will _(1)_ and the Reactor will scram due to _(2)_.
A. (1) open ;
(2) high pressure.
B. (1) fail open ; (2) MSIV closure after a low steam line pressure.
C. (1) fail closed ; (2) high pressure.
D. (1) open ;
(2) turbine stop valve fast closure.
Proposed Answer:
A Explanation A. Correct - BPVs remain available for automatic pressure control due to an independent hydraulic system; due to the turbine trip, pressure will rise and the BPVs will try to control pressure by opening. If power were above 30.92%, then the Control Valve Fast closure scram would be enabled to send a trip signal to RPS, but this feature is not enabled so pressure will rise until the high pressure scram setpoint.
B. BPVs remain available for automatic pressure control due to an independent hydraulic system.
C. BPVs remain available for automatic pressure control due to an independent hydraulic system.
D. See A.
Technical Reference(s):
R-STM-0509, pp. 15, 54 of 81 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0509, Obj 10d Question Source:
Bank #
RBS-OPS-3478 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.7 Comments: Replaced question to better match the KA
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 4
QUESTION 4 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295006 AK3.03 IR 3.8 Knowledge of the operational implications of the following concepts as they apply to SCRAM: Reactor pressure response Proposed Question:
A reactor plant has been operating at 100% power for an extended period when a scram occurs. Operators are executing AOP-0001, Reactor Scram. For a period of several minutes after the scram, there will be a _(1)_ due to _(2)_.
A. (1) drop in RPV level; (2) Recirc pumps shifting to slow speed B. (1) rise in RPV level; (2) rise in void content C. (1) rise in reactor pressure; (2) decay heat D. (1) drop in reactor pressure; (2) automatic operation of SRVs Proposed Answer:
C Explanation A. Part 1 is correct, but it is due to an automatic feature of the feed water level control system; not because of Recirc pumps shifting.
B. Part 1 is seen in plant operation due to the setpoint set down feature of the Feedwater level control system; it is not because of void content.
C. Correct - reactor pressure does go up and must be controlled with one of the following: the turbine, turbine bypass valves, or safety relief valves (IAW AOP-1); the reason pressure rises for several minutes after a scram is because of decay heat: 7% for first 8-10 seconds, then drops to about 1% after 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
D. Both parts are incorrect: for part 1 see C Technical Reference(s):
GFES - Reactor Operational Physics, pp. 63-64 of 83; AOP-0001 Proposed references to be provided to applicants during examination:
None Learning Objective:
GFES Reactor Operational Physics, Obj 31 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.1 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 5
QUESTION 5 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295016 AA1.06 IR 4.0 Knowledge of the operational implications of the following concepts as they apply to CONTROL ROOM ABANDONMENT:
Reactor water level Proposed Question:
The Main Control Room must be abandoned due to Halon actuation; there is not a fire in the MCR. In accordance with AOP-0031, Shutdown from Outside the Main Control Room, what systems will be initiated for RPV level control?
A. LPCS, HPCS, and RCIC B. HPCS, and RCIC only C. RCIC only D. All Division 1 ECCS systems Proposed Answer:
A Explanation A. Correct - Subsequent actions for abandonment of the control room without a fire direct initiation of HPCS, LPCS, and RCIC.
B. See A this answer does not include LPCS C. See A this answer does not include LPCS or RCIC D. See A this answer does not include HPCS, and should not include RHR-A Technical Reference(s):
AOP-0031, Rev 322 p.10 of 122 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-OPS-AOP-0031, Obj 4 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 6
QUESTION 6 Rev 1 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295018 AA2.04 IR 2.9 Ability to determine and/or interpret system flow as it applies to PARTIAL OR COMPLETE LOSS OF COMPONENT COOLING WATER.
Proposed Question:
With the plant operating at 100%, the following annunciators are received:
TURB CMPNT CLG WATER SYSTEM LOW PRESSURE TURB CMPNT CLG WTR SYS SURGE TK LOW LEVEL On H13-P870, the unit operator observes:
All 3 CCS pumps are running with elevated amps MWS-AOV132 TPCCW SURGE TK MAKE-UP VALVE is OPEN Which of the following is the cause of the above?
A. CCS piping failure has caused a loss of inventory.
B. GSN-PCV1C, MANIFOLD REGULATOR (Nitrogen Pressure Control Valve to TPCCW Surge Tank) has failed closed.
C. CCS-LT113, SURGE TANK LEVEL TRANSMITTER has failed low.
D. CCS-PV111, MINIMUM FLOW AND PRESSURE CONTROL VALVE, has failed OPEN.
Proposed Answer:
A Explanation A. Correct - A large leak would cause all the indications, low pressure - starts stby pump, max amps as the pumps operate in runout condition, and loss of inventory causes the surge tank low level condition and opening of the makeup valve.
B. The TPCCW surge tank is blanketed with 18 psig nitrogen for NPSH and for corrosion control; if this valve fails closed it would lower system pressure, but not surge tank level.
C. The surge tank level transmitter failing low would cause the surge tank low level alarm and the opening of the surge tank makeup valve, but would not cause all pumps to run with maximum amps, nor would it cause a system low pressure alarm.
D. This would lower system pressure, but would not account for a low Surge Tank level.
Technical Reference(s):
ARP-P870-55-B01, C02, PID 09-07A Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-116 Obj 2, 5 Question Source:
Bank #
RBS Audit Exam, March 2010 #6 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.4 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 7
QUESTION 7 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295019 G2.4.47 IR 4.2 Ability to diagnose and recognize trends in an accurate and timely manner utilizing the appropriate control room reference material.
Proposed Question:
The plant is operating at 100% power when the following alarms annunciate:
P870-51A-A01, INSTRUMENT AIR COMPRESSOR TROUBLE P870-51A-B01, SAS COMPRESSOR ALIGNED TO IA SYSTEM The Unit Operator notices the following:
Instrument Air Header Pressure on IAS-PI105 is trending downward at a rate of 1 psig every 10 seconds.
A and B IAS compressors amber lights lit; C IAS compressor red light is lit Assuming the situation continues to degrade, which of the following represents the correct sequence of events?
A. Feedwater Reg Valves Lock-up; then SAS-AOV133, Service Air Header Block Valve, closes; then MSIVs fail shut B. Instrument Air to the Lower Fuel Pools Gate Seals is replaced by the passive nitrogen back-up system; then Feedwater Reg Valves Lock-up; then Condensate and Heater Drain Pump Recirc valves fail open C. P870-51A-B02, Instrument Air Header Pressure Low Annunciator Alarms; then SAS-AOV133, Service Air Header Block Valve, closes; then Feedwater Reg Valves Lock-up D. Feedwater Reg Valves Lock-up; then P870-51A-B02, Instrument Air Header Pressure Low Annunciator Alarms; then MSIVs fail shut Proposed Answer:
C Explanation A. (also B. and D.) See C C. Correct - the cross tie valve opens at 113 psig; the low air header pressure alarm and the service air block valve closing both occur at 110 psig ; FRVs lock-up at 85 psig; MSIVs go closed at 65 psig; Fuel Pool Gates switch to nitrogen at 32 psig.
Technical Reference(s):
AOP-0008, Loss of Instrument Air, Rev 37, p. 4 of 21 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-0527, Obj 4 Question Source:
Modified Bank # RBS December 2008 NRC Exam #8 Question History:
Last NRC Exam December 2008 NRC Exam #8 Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 8
QUESTION 8 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295021 AK1.03 IR 3.9 Knowledge of the operational implications of the following concepts as they apply to LOSS OF SHUTDOWN COOLING :
Adequate core cooling Proposed Question:
The plant has been in MODE 4 for 25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br />, cooling down for a refueling outage with the following conditions:
RHR-B is in Shutdown Cooling mode of operation Recirc Pump A is tagged out Recirc Pump B is running in slow speed Reactor Coolant Temperature is 190F RPV level +38 and steady RHR Pump B trips on motor overload and RHR Pump A will not start.
Which of the following operator actions would assure adequate core cooling?
A. Align RWCU for Alternate Shutdown Cooling.
B. Align for Main Steam Line Flooding C. Align SPC/ADHR in Configuration 1 D. Raise RPV level to greater than 75 inches Proposed Answer:
C Explanation A. RWCU is only aligned for ADHR in mode 5 with coolant temperature below 125F B. MSL Flooding can only be used between 120 and 170F C. Correct - SPC/ADHR is available when reactor coolant temperature is below 200F (Configuration 1 takes a suction from SDC and discharges through LPCI-C injection line)
D. Raising RPV level to +75 ensures natural circulation to prevent stratification and inadvertent pressurization, but does not assure adequate core cooling Technical Reference(s):
OSP-0041, Alternate Decay Heat Removal, Rev 306 pp 8, 18, 40 AOP-0051, Loss of Decay Heat Removal, Rev 312 pp 5&6 of 30 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-543, Obj 5 Question Source:
Bank 2010 Grand Gulf NRC exam Q#40 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 9
QUESTION 9 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295023 AK2.05 IR 3.5 Knowledge of the interrelations between REFUELING ACCIDENTS and the following: Secondary containment ventilation Proposed Question:
Refueling operations are in progress when an irradiated fuel bundle is dropped in the spent fuel pool. The refueling team on the lower bridge reports bubbles rising from the dropped fuel bundle and the following annunciators are received in the MCR:
H13-P863-75A-H01, DIV I Fuel Bldg Exh PAM Gaseous Radn Alarm RMS-DSPL230-1GE005, Fuel Build Stack/Vent Exhaust A - High RMS-DSPL230-2GE005, Fuel Build Stack/Vent Exhaust A - High Which of the following describes the Fuel Building ventilation lineup after the conditions given above?
A. Fuel Building Ventilation is completely isolated B. Supply air is via normal supply fans and exhaust is through the Div 1 charcoal filter trains C. Supply air is via Fuel Receiving Area and exhaust is through both Div 1 and Div 2 charcoal filter trains D. Supply air is via Fuel Receiving Area and exhaust is through the Div 1 charcoal filter trains Proposed Answer:
C Explanation A. A high radiation condition in the fuel building does not isolate the ventilation system; it isolates the normal supply and exhaust fans, and starts the charcoal filtration system.
B. A high radiation condition in the fuel building isolates the normal supply and exhaust fans, and starts the charcoal filtration system.
C. Correct - RMS-RE5A is the instrument that drives all three annunciators; this instrument will start the Div 1 filter train only, however a low flow signal will also start the Div 2 train.
D. This instrument will send a start signal to the Div 1 filter train only, but both will start (see C)
Technical Reference(s):
R-STM-0406, pp 19 & 41 of 50, ARP-H13-P863-75A-H01 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0406, Obj 11 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 10 QUESTION 10 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295024 EK3.06 IR 4.0 Knowledge of the reasons for the following responses as they apply to HIGH DRYWELL PRESSURE: Reactor Scram Proposed Question:
What is the reason for the reactor scram that occurs due to a High Drywell Pressure?
A. To minimize the possibility of fuel damage due to a reactor coolant pressure boundary leak by reducing the amount of energy being added to the coolant.
B. To ensure the Pressure Suppression function of the containment is maintained in the event Emergency Depressurization is required.
C. To ensure that offsite dose limits are not exceeded during a reactor coolant pressure boundary leak.
D. To avoid clearing of the suppression pool vents due to high drywell pressure.
Proposed Answer:
A Explanation A high drywell pressure condition results due to a leak of the primary system. Due to the loss of coolant, an inability to cool the fuel may result. A reactor scram occurs to minimize the energy being produced.
The pressure suppression function of the containment is based on containment pressure not drywell pressure. Offsite dose limits are prevented from being exceeded by the high drywell pressure containment isolation, not the high drywell pressure reactor scram. Although the scram signal will reduce the energy being leaked into the drywell, and may avoid clearing of the suppression pool vents, this is not the reason for the scram.
Technical Reference(s):
R-STM-0508, RPS, Rev 6 p. 46 of 59 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0508 Obj 2 Question Source:
Bank #
2008 NRC Exam Q#11 Question History:
Last NRC Exam RBS 2008 Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.6 Comments: Rejected KA: EK3.04 ; Randomly selected new KA statement EK3.06 (RBS has no guidance to Emergency Depressurize for a High DW D/P
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 11 QUESTION 11 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295025 EA1.05 IR 3.7 Ability to operate and/or monitor the following as they apply to HIGH REACTOR PRESSURE: RCIC: Plant-Specific Proposed Question:
The plant is operating at 93% power.
A RCIC lube oil change has just been completed and RCIC has been started with the slow-roll startup section of SOP-0035 in the RPV Pressure Control lineup (CST to CST). All MSIVs go closed and the reactor scrams.
What is the status of RCIC after the scram?
A. RCIC will isolate on steam supply line high flow.
B. RCIC will re-align to inject to the RPV.
C. RCIC will isolate on high steam line pressure.
D. RCIC will remain in a CST to CST lineup.
Proposed Answer:
D Explanation A. High steam line flow can be a cause for RCIC isolation, but MSIV isolation does not cause this.
B. RCIC initiation occurs at RPV Level 2 (-43)
C. Low Steam Line Pressure, not high, can cause a RCIC isolation D. Correct - There is no logic setpoints reached to cause a realignment of RCIC Technical Reference(s):
R-STM-0209, Rev 10, pp. 26,27,43 of 52 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0209, Obj 7, 12 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 12 QUESTION 12 Rev 1 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295026 EA2.03 IR 3.9 Ability to determine and/or interpret the following as they apply to SUPPRESSION POOL HIGH WATER TEMPERATURE: Reactor pressure Proposed Question:
Following a loss of offsite power, the plant is experiencing an ATWS. Suppression Pool level is currently 19 feet, 11 inches.
In accordance with the Pressure leg of EOP-1A, RPV Control, ATWS, which of the following pressure band/suppression pool temperature combinations would result in the need for emergency depressurization?
RPV Pressure Supp Pool Temperature A. 800 - 1090 psig 131F B. 800 - 1090 psig 137F C. 500 - 700 psig 139F D. 500 - 700 psig 142F Proposed Answer:
B Explanation B. Correct - The pressure leg of EOP-1A has an override step in RPA-4 that directs maintaining RPV pressure below the HCTL: Suppression pool level, stated as 1911 in the stem, requires the examinee to use the 196 line on the HCTL curve (not allowed to interpolate). The pressure bands are common given bands for the given plant condition and the top of the band must be used to determine if the HCTL will be reached. The lowest s.p. temperature that would require ED for 700 psig is 145F; the lowest temperature for 1090 psig is 133F.
Technical Reference(s):
EOPs, Heat Capacity Temperature Limit Curve Proposed references to be provided to applicants during exam: Heat Capacity Temperature Limit Curve Learning Objective:
RLP-HLO-517, Obj 2 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 13 QUESTION 13 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295027 G2.4.20 IR 3.8 Knowledge of the operational implications of EOP warnings, cautions, and notes Proposed Question:
A suppression pool temperature of 180F may result in ___.
A. direct pressurization of containment from RCIC turbine exhaust during operation.
B. damage to the RCIC turbine during operation due to reduced lube oil cooling.
C. inability to monitor suppression pool temperature due to instrument being off scale high.
D. inability to monitor suppression pool level due to temperature being greater than instrumentation environmental ratings.
Proposed Answer:
B Explanation A. Direct pressurization is a concern with a high suppression pool level, not temperature (EOP Caution 4)
B. Correct-the lube oil and control oil for RCIC is cooled by process flow; the max allowable cooling water temperature for RCIC lube oil is 140F (EOP Caution 3)
C. Design temperature of containment is 185F, some of the RTDs are designed for Post Accident Monitoring and are tested to readings of 200F. (STP-555-4203)
D. See explanation in C; EOP Caution 7 warns of the inability to trust suppression pool temperatures with suppression pool water level too low.
Technical Reference(s):
EOP-1 Caution 3, Bases p. B-5-10 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-OPS-HLO-511, Obj 6 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 4 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.9 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 14 QUESTION 14 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295028 EK1.01 IR 3.5 Knowledge of the operational implications of the following concepts as they apply to HIGH DRYWELL TEMPERATURE:
Reactor water level measurement Proposed Question:
EOP-1 Caution 1, part 2 identifies RPV levels above which RPV level instruments may be used when the containment or drywell temperature near the reference legs is at the specified limits. At these elevated RUN TEMPERATURES, the instrument would ___.
A. continue to indicate level on-scale when actual RPV level went off-scale high (above the indicating range).
B. fail off-scale low.
C. continue to indicate level on-scale when actual RPV level went below the variable leg tap.
D. provide erratic level indication when actual RPV level went off-scale low due to loss of the variable leg.
Proposed Answer:
C Explanation A. Caution 1 deals with low RPV level, not high B. see C.
C. Correct-indicated level would be on-scale while actual level would be below the variable leg tap.
D. Erratic indication would be a sign of boiling in the reference leg.
Technical Reference(s):
EOP Caution 1, Bases p. B-5-2 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-OPS-HLO-511, Obj 6 Question Source:
Bank #
RBS-NRC-706 Question History:
Last NRC Exam Audit Exam March 2008 Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.2 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 15 QUESTION 15 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295030 EK2.08 IR 3.5 Knowledge of the interrelations between LOW SUPPRESSION POOL WATER LEVEL and the following: SRV discharge submergence Proposed Question:
For normal SRV operations, which of the following suppression pool levels is based on direct pressurization of containment air space?
A. 13 feet B. 15 feet, 5 inches C. 21 feet, 3 inches D. 21 feet, 6 inches Proposed Answer:
A Explanation A. Correct - This is the elevation of the top of the SRV discharge device below which opening of an SRV may cause pressurization of the containment air space B. 155 is 2 feet above the horizontal vents; this level is associated with a leak from the DW passing through the horizontal vents.
C. 213 is the SRV tail pipe level limit; operation of an SRV above this limit may cause damage to the SRV discharge lines.
D. 216 is based on the Pressure Suppression Pressure (PSP) Curve; the PSP pressure is a function of suppression pool level.
Technical Reference(s):
EOP Bases p. B-6-56 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-514, Obj 5 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.9 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 16 QUESTION 16 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295031 EK2.03 IR 4.2 Knowledge of the interrelations between REACTOR LOW WATER LEVEL and the following: Low pressure core spray Proposed Question:
An STP is being performed that directs the operator to close E21-MOV F011, LPCS Min Flow Valve; all other valves are in their normal, standby positions. A valid RPV low level, Low Pressure Core Spray (LPCS) initiation signal is received.
Assuming no operator action, how will the LPCS system respond?
A. The LPCS Min Flow Valve will remain closed until the initiation signal is reset.
B. The LPCS Min Flow Valve will open until system flow rises above 875 gpm.
C. The LPCS Pump will not receive a start signal because of the pump protection logic permissive not being met.
D. The LPCS Pump will start and will eventually overheat.
Proposed Answer:
B Explanation A. The reset pushbutton is in the LPCS initiation sequence logic; the min flow valve is not part of this logic.
B. Correct - the design logic for the min flow valve is to OPEN when the pump breaker is closed and the sensed flow is less than 875 gpm.
C. The pump start logic does not include a permissive from the min flow valve D. The pump would overheat without a flow path providing at least 500 gpm; the min flow valve will open with the given conditions.
Technical Reference(s):
R-STM-0205 pp.13-14,16 of 33 ; STP-205-4201, Rev 301 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0205, Obj 4,9 Question Source:
Modified Bank # RBS-OPS-5554 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 17 QUESTION 17 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295037 EA1.06 IR 4.1 Ability to operate and/or monitor the following as they apply to SCRAM CONDITION PRESENT AND REACTOR POWER ABOVE APRM DOWNSCALE OR UNKNOWN: Neutron monitoring system Proposed Question:
The plant was operating at 80% power when a transient in the Fancy Point Switchyard resulted in a Main Turbine trip. All control rods did not fully insert.
Current parameters:
Reactor Power 22.5%
Reactor Pressure 900 psig RPV Level
-50 inches (Wide Range)
Feed Flow 2.79 Mlbm/hr IRM and SRM detectors have been inserted Main Steam Bypass Valves are both full open Two SRVs are open To avoid exceeding the Heat Capacity Temperature Limit Curve, the CRS has directed pressure lowered to 700 psig using SRVs.
Immediately following the opening of SRVs, indicated reactor power will ___.
A. rise due to the lowering of the reactor coolant temperature adding positive reactivity.
B. rise due to the water level inside the core rising, causing more neutron moderation.
C. lower due to voiding as the water in the core flashes to steam.
D. lower due to the moderator temperature rising with the low flow in the core.
Proposed Answer:
C Explanation A. reactor power would lower; later as pressure stabilizes, and the water that flashed to steam is replaced with Feedwater, coolant temperature will add positive reactivity, but not immediately.
B. reactor power would lower; voiding causes less moderation C. Correct - lowering pressure will flash the water in the core and therefore causing void volume to rise.
Neutron moderation would decrease, thereby lowering power.
D. reactor power will lower, but it is due to voiding, not a temperature change Technical Reference(s):
GFES Components BC070 Proposed references to be provided to applicants during examination:
None Learning Objective:
BC07022 Question Source:
Bank #
RBS-NRC-569 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.1 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 18 QUESTION 18 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295038 EA2.03 IR 3.5 Ability to determine and/or interpret the following as they apply to HIGH OFF-SITE RELEASE RATE: Radiation levels Proposed Question:
The radioactivity release control leg of EOP-0003, Secondary Containment and Radioactive Release Control is entered when radiation monitors reach the rate levels corresponding to the ___ action level defined in the Site Emergency Plan.
A. NOUE B. ALERT C. SITE AREA EMERGENCY D. GENERAL EMERGENCY Proposed Answer:
B Explanation A. NOUE is below the entry level for EOP-0003 B. Correct-Entry into EOP-0003 radioactive release leg corresponds to the ALERT action level; radiation monitors setpoints are set accordingly.
C. See B D. See B Technical Reference(s):
EOP-0003 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-515, Obj 2 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 19 QUESTION 19 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
600000 G2.4.11 IR 4.0 Knowledge of abnormal condition procedures Proposed Question:
The plant is operating at 100% power. Standby Gas Treatment Filter Train "A" is being operated for surveillance testing.
The Auxiliary Building Operator reports smoke coming from the "A" Standby Gas Treatment Filter Train and the filter train case is glowing red.
Which one of the following describes the method to combat a fire in the Standby Gas Treatment Filter Train?
A. The Fire Protection System will initiate the automatic deluge system and fill the filter train with water.
B. The Fire Protection System will automatically open a deluge isolation valve, however, valves must be manually opened to admit water to the filter train.
C. The Fire Protection system Deluge Valve will have to be manually initiated via the pull station to admit water to the filter train.
D. The Fire Protection System at the filter train must be manually valved in to admit water to the filter train.
Proposed Answer:
D Explanation A. There is no automatic fire suppression for the GTS train B. The isolation valves must be manually opened, however there is no auto fire suppression for GTS C. Some deluge systems on site have this capability but not for the GTS train D. The isolation valves must be manually opened, no deluge valve actuation is needed.
Technical Reference(s):
Pre-Fire Strategy AB-141-531 SGTS Filter A Room Fire Area AB-14 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0257, Obj 4 Question Source:
Bank # RBS-NRC-654 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 20 QUESTION 20 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
700000 AK1.03 IR 3.3 Knowledge of the operational implications of the following concepts as they apply to GENERATOR VOLTAGE AND ELECTRIC GRID DISTURBANCES: Under-excitation Proposed Question:
Under-excitation of the Main Generator results in ___.
A. Turbine rotor overheating.
B. Generator field overheating.
C. the Voltage Regulator shifting to Manual.
D. Generator armature overheating.
Proposed Answer:
D Explanation A. A loss of generator field causes turbine torque oscillation which leads to the Turbine rotor overheating.
B. Over-excitation causes the Generator field to overheat.
C. An exciter field overcurrent causes the Voltage Regulator to shift to Manual.
D. Correct - Under-excitation causes overheating of the armature.
Technical Reference(s):
R-STM-0310, Rev 8 p. 29 of 76 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0310, Obj 3,10 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41b.5 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 21 QUESTION 21 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
295007 AK2.01 IR 3.5 Knowledge of the interrelations between HIGH REACTOR PRESSURE and the following: Reactor/turbine pressure regulating system Proposed Question:
The plant is starting up and is currently operating at 60% power when the A Recirc. Flow Control valve ramps open.
How will the EHC pressure control system respond to this condition?
The EHC pressure control system will cause generator load to _(1)_ and reactor pressure will _(2)_
A. (1) rise (2) lower B. (1) rise (2) remain steady C. (1) lower (2) lower D. (1) lower (2) remain steady Proposed Answer:
B Explanation As the FCV opens at this power level reactor power will rise and reactor pressure will follow. The pressure regulating system will open the turbine control valves causing generator load to rise. Reactor pressure will remain the same as the turbine control valves open to control reactor pressure. B is the correct answer.
Technical Reference(s):
R-STM-0509, Rev 14 p.51 of 81 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0509, Obj 10 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.5 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 22 QUESTION 22 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
295008 AA2.05 IR 2.9 Ability to determine and/or interpret the following as they apply to HIGH REACTOR WATER LEVEL: Swell Proposed Question:
River Bend was operating at full power with RCIC tagged out. A loss of offsite power occurred and HPCS recovered RPV level. Operators have closed the HPCS injection valve with an RPV water level of +20 inches. Current conditions are as follows:
MSIVs are closed Reactor pressure is 700 psig and rising at 10psig per minute Time after scram is 5 minutes Drywell pressure is 0.3 psid What is the expected RPV water level response over the next 10 minutes and why?
A. RPV level will rise due to swell from decay heat B. RPV level will rise due to feed regulating valve leak by C. RPV level will lower due to cool down D. RPV level will lower due to injection being secured Proposed Answer:
A Explanation A. Correct-Level rises due to expansion cause by the heat up from decay heat B. Feedwater is not available due to the loss of offsite power C. RPV water level will rise not lower D. RPV water level will rise not lower Technical Reference(s):
RLP-HLO-168, Rev 06, Thermodynamics: Steam, pp. 35-37 of 73 Proposed references to be provided to applicants during examination:
None Learning Objective:
HLO-167, Obj 2 Question Source:
Modified Bank # RBS-NRC-01108 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.14 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 23 QUESTION 23 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
295011 G2.4.04 IR 4.5 Ability to recognize abnormal indications for system operating parameters that are entry-level conditions for emergency and abnormal operating procedures: High Containment Temperature Proposed Question:
Based on the following conditions, which one of the following describes the Emergency Operating Procedure(s) that should be entered?
Reactor Power 0% (all rods in)
RPV Pressure 970 psig RPV Level 20 inches Containment Temperature 92F Containment Pressure 0.25 psig Drywell Temperature 140F Drywell Pressure 0.75 psid Annulus Differ. Pressure
-1.3 in WC A. EOP-1, RPV Control ONLY B. EOP-1, RPV Control AND EOP-2, Primary Containment Control C. EOP-2, Primary Containment Control ONLY D. EOP-2, Primary Containment Control AND EOP-3, Secondary Containment and Radioactivity Release Proposed Answer:
C Explanation A. No EOP-1 Entry Condition exists.
B. No EOP-1 Entry Condition exists C. Correct-EOP-0002 Entry Condition is Containment Temperature above 90F D. No EOP-3 Entry Condition exists.
Technical Reference(s):
EOP-1, -2, and -3 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-514, Obj 3 Question Source:
Modified Bank #
RBS-NRC-444 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments: KA rejected because there is no Alarm or ARP for Cont. High Temperature.
Redrew from the 50 possible choices in the G2.4 category to get 2.4.4
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 24 QUESTION 24 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
295012 AK1.02 IR 3.1 Knowledge of the operational implications of the following concepts as they apply to HIGH DRYWELL TEMPERATURE :
Reactor power level control Proposed Question:
Prior to Emergency Depressurization on High Drywell Temperature, EOP-1 is directed to be entered to assure, if possible, ___.
A. that RPV pressure is lowered as low as possible by steam loads before RPV depressurization is initiated.
B. that the reactor is scrammed and shutdown by control rod insertion before RPV depressurization is initiated C. that RPV water level is raised as high as possible by Feed water before RPV depressurization is initiated D. that the suppression pool is cooled and lowered by RHR before RPV depressurization is initiated Proposed Answer:
B Explanation A. While a lower pressure is desirable it is not specifically directed by the EOP prior to ED B. Correct-Per EOP Bases the reactor is scrammed and shutdown if possible to minimize the amount of energy sent to containment C. While a higher level is desirable to minimize inventory loss it is not specifically directed by the EOP prior to ED D. While a cooler suppression pool is desired it is not directed by EOP-0001 Technical Reference(s):
EOP BASES p. B-8-6 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-514, Obj 5 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.9 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 25 QUESTION 25 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
295013 AK2.01 IR 3.6 Knowledge of the interrelations between HIGH SUPPRESSION POOL TEMPERATURE and the following: Suppression pool cooling Proposed Question:
A safety relief valve has opened and AOP-0035, SAFETY RELIEF VALVE STUCK OPEN has been entered. Following reduction in reactor power to 89%, the CRS has directed you to place RHR A in suppression pool cooling mode.
Why is suppression pool cooling initiated?
A. to obtain localized suppression pool temperature B. to minimize containment atmospheric activity C. to reject suppression pool level D. to establish bulk mixing of the suppression pool Proposed Answer:
D Explanation A. T.S. and TRM actions are based on average temperature not localized temperature B. SP cooling does not significantly affect containment activity levels and the reason for establishing SP cooling is to establish bulk mixing and to cool the pool C. While reject may become required, the reason for establishing SP cooling is to establish bulk mixing and to cool the pool D. Correct-RHR A is placed in suppression pool cooling mode to establish bulk mixing of the suppression pool such that an average suppression pool temperature may be obtained Technical Reference(s):
AOP-0035, Safety Relief Valve Stuck Open, Rev 19 p. 5 of 10 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-OPS-AOP035, Obj 4 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 26 QUESTION 26 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
295029 EK3.03 IR 3.04 Knowledge of the reasons for the following responses as they apply to HIGH SUPPRESSION POOL WATER LEVEL :
Reactor SCRAM Proposed Question:
EOP-2, Suppression Pool Level Control, requires entry into EOP-1, RPV Control if suppression pool level cannot be maintained below 21 feet.
Entering EOP-1 ___.
A. will allow actions to take place that support terminating injection of water from sources external to containment.
B. will force a scram and shutdown of the reactor; this will make the requirement of maintaining Suppression Pool Level below 21 feet no longer applicable.
C. will allow for a reactor shutdown prior to flooding the drywell.
D. is required so the required emergency depressurization can be accomplished.
Proposed Answer:
A Explanation A. Correct-EOP bases states that prior entry to EOP-1 requires control of RPV level and reactor power and therefore, facilitates making the determination if a system taking suction from a source external to the containment is needed for RPV injection or to shutdown the reactor B. EOP-2 is still applicable when the reactor is shutdown C. EOP-1 entry on SP level is based on SRV component loading and injection source termination.
D. EOP-1 entry on SP level is based on SRV component loading and injection source termination Technical Reference(s):
EOP Bases p. B-8-21 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-514, Obj 5 Question Source:
Bank #
RBS-NRC-20 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 27 QUESTION 27 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
295032 EA1.01 IR 3.6 Ability to operate and/or monitor the following as they apply to HIGH SECONDARY CONTAINMENT AREA TEMPERATURE : Area temperature monitoring system Proposed Question:
The plant is at 100% power.
Alarm P601/21A/H02, AIR TEMP MON R608 RCIC RM TEMP HIGH is received. The CRS has directed you to monitor and trend the value for the high area temperature.
What temperature monitoring equipment will be used to obtain this information?
A. ERIS computer data via the Plant Data Server System B. H13-P632 Vent Diff Temperature recorder C. H13-P632 Area Temperature recorder D. Local temperature monitoring by a building operator Proposed Answer:
C Explanation A. The ERIS computer does not monitor this area of secondary containment B. This recorder only supplies unit cooler differential temperature indication C. The alarm response procedure directs the use of H13-P632 Area Temperature recorder D. While this is not disallowed the alarm setpoint for this alarm is 144ºF and is a high dose area. This would be a safety and rad concern to enter the area to obtain temperatures.
Technical Reference(s):
P601-21A-H02 PDS data point list Proposed references to be provided to applicants during examination:
None Learning Objective:
None Identified Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 28 QUESTION 28 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
203000 K4.03 IR 3.2 Knowledge of RHR/LPCI: INJECTION MODE (PLANT SPECIFIC) design feature(s) and/or interlocks which provide for the following: Pump minimum flow protection Proposed Question:
The reactor has been shut down due to a transient.
Current plant conditions are:
Reactor pressure is 528 psig and slowly decreasing Reactor water level is -120 inches and slowly decreasing Drywell pressure is 1.78 psid and slowly increasing All low pressure ECCS systems are running as designed What is the status of the RHR C system?
A. Injection valve (F042C) is open and pump minimum flow valve F064C is closed.
B. Injection valve (F042C) is open and pump minimum flow valve F064C is open.
C. Injection valve (F042C) is closed and pump minimum flow valve F064C is closed.
D. Injection valve (F042C) is closed and pump minimum flow valve F064C is open.
Proposed Answer:
D Explanation A. and B are not correct, the injection valve, F064C will not open until reactor pressure is below 487 psig.
C. With the injection valve closed, system flow will be 0 gpm, the min flow valve is a normally open valve and is interlocked to open when flow is <1100 gpm.
D. Correct, see C Technical Reference(s):
R-STM-0204, RHR, Rev 11 pp. 12,14,15 of 63 Proposed references to be provided to applicants during examination: None Learning Objective: RLP-STM-0204, Obj 6 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content:
55.41.b.7 Comments: Rejected KA K4.09 ; for inability to write psychometrically sound question; Randomly selected K4.03 Wording of KA suggests How do design features/interlocks provide for STPs
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 29 QUESTION 29 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
205000 K5.02 IR 2.8 Knowledge of the operational implications of the following concepts as they apply to SHUTDOWN COOLING SYSTEM (RHR SHUTDOWN COOLING MODE) : Valve operation Proposed Question:
The plant is shut down. RHR A is operating in Shutdown Cooling mode (SDC) with an RPV water level of 75 inches.
Operation from the main control room of which of the following valves would lead to an OPDRV (Operations with a Potential to Drain the Reactor Vessel)?
A. E12-F004A, RHR PUMP A SUP PL SUCTION VALVE B. E12-F006A, RHR PUMP A SDC SUCTION VALVE C. E12-F024A, RHR PUMP A TEST RTN TO SUP PL D. E12-F042A, RHR PUMP A LPCI INJECTION ISOL VALVE Proposed Answer:
C Explanation A. Interlocks prevent opening of E12-F004A with E12-F006A already open B. closure of E12-F006A would cause to the RHR pump to trip but would not cause an OPDRV C. Correct-There are no interlocks preventing operation and opening of E12-F024 would direct RPV water to the suppression pool D. Open of E12-F042A would redirect water through the LPCI injection line but would not cause an OPDRV Technical Reference(s):
R-STM-0204, RHR, Rev 11 pp. 16,21 of 63 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0204, Obj 6 Question Source:
Bank #
RBS-NRC-182 Question History:
Last NRC Exam NRC Exam 7/1997 Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 30 QUESTION 30 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
209001 K6.03 IR 3.3 Knowledge of the effect that a loss or malfunction of the following will have on the LOW PRESSURE CORE SPRAY SYSTEM : Torus/suppression pool water level Proposed Question:
The Low Pressure Core Spray (LPCS) pump should not be run with suction from the suppression pool if level is less than 13 ft 3in, except in accordance with the EOPs because of the need to ____.
A. install an EOP-0005 enclosure to allow operation.
B. assure adequate net positive suction head.
C. provide cooling to the pump bearings.
D. maximize pump injection time following a LOCA.
Proposed Answer:
B Explanation A. There are NO interlocks between suppression pool level and LPCS operation B. Correct-SOP-0032 Precaution and Limitation 2.10 Lists 133 as the necessary level to assure NPSH C. The pump bearings are NOT cooled by system flow D. While a high suppression pool level will allow longer pump run time prior to loss of NPSH it is not the reason behind the limitation of 133 Technical Reference(s):
SOP-0032, LPCS, Rev 23 P&L 2.10 (p. 3 of 30)
Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0205, Obj 8 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 31 QUESTION 31 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
209001 A3.03 IR 3.5 Ability to monitor automatic operations of the LOW PRESSURE CORE SPRAY SYSTEM including: System pressure Proposed Question:
The Low Pressure Core Spray (LPCS) system is running in the test return to the suppression pool mode at 5050 gpm.
A leak has caused drywell pressure to increase to 1.95 psid.
Reactor water level is -62 inches Reactor pressure is 450 psig Which of the following identifies the expected AUTOMATIC response?
A. The Test Return Valve to the Suppression Pool (E21-F012) closes, Injection Isolation Valve (E21-F005) opens and discharge pressure rises.
B. The Test Return Valve to the Suppression Pool (E21-F012) closes, Injection Isolation Valve (E21-F005) opens and discharge pressure lowers.
C. The Test Return Valve to the Suppression Pool (E21-F012) remains open, Injection Isolation Valve (E21-F005) remains closed and discharge pressure rises.
D. The Test Return Valve to the Suppression Pool (E21-F012) remains open, the Injection Isolation Valve (E21-F005) remains closed and discharge pressure lowers.
Proposed Answer:
A Explanation A. Upon a LOCA signal of 1.68 drywell diff pressure the LPCS system automatically aligns to inject into the RPV, the test return valve closes, if open, the injection valve opens, if RPV pressure is below 487 psig and the min flow valve opens if flow drops below 875 gpm. Since the stem RPV pressure is below the injection valve interlock pressure but above the pump shut off head (282 psig) the injection valve will open but the pump will not flow into the RPV. The min flow valve will open, flow will drop from the 5050 gpm and discharge pressure will rise. For these reasons all other choices are incorrect.
B, C, D. See A Technical Reference(s):
R-STM-0205, LPCS, Rev 5 pp. 17-18 Proposed references to be provided to applicants during examination: None Learning Objective:
RLP-STM-0205, Obj 9 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 4 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 32 QUESTION 32 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
209002 A1.08 IR 3.1 Ability to predict and/or monitor changes in parameters associated with operating the HIGH PRESSURE CORE SPRAY SYSTEM (HPCS) controls including: System lineup: BWR-5,6 Proposed Question:
Following a loss of normal Feedwater, HPCS initiated and is restoring level. At 0 inches in the RPV, the operator closes the HPCS injection valve. How will the HPCS Discharge Pressure and HPCS Flow Rate parameters change?
Discharge Pressure Flow Rate A. Rise Rise B. Rise Lower C. Lower Rise D. Lower Lower Proposed Answer:
B Explanation A. See B B. Correct-as the pumps discharge is constrained to the min flow capacity of 500 gpm, discharge pressure will rise and flow rate will lower C. See B D. See B Technical Reference(s):
R-STM-0203, HPCS, Rev 8 pp.15,16,20 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0203, Obj 9 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.8 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 33 QUESTION 33 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
211000 K5.06 IR 3.0 Knowledge of the operational implications of the following concepts as they apply to STANDBY LIQUID CONTROL SYSTEM: Tank level measurement Proposed Question:
An ATWS has occurred and the CRS has directed SLC injection. The hard card directs you to monitor SLC tank level and to report when Hot Shutdown Boron Weight is achieved. If the initial SLC tank level is 2666 gallons, which of the following is the highest tank level at which Hot Shutdown Boron Weight should be reported as having been injected?
A. 1986 gallons B. 2036 gallons C. 1866 gallons D. 1966 gallons Proposed Answer:
D Explanation A. See D B. See D C. See D D. Correct-Note above tank levels in OSP-0053 states that When tank level falls between values, then the smaller value should be used, with an initial value of 2666 gallons the level must be the highest level that is below 1974 gallons which is 1966 gallons Technical Reference(s):
OSP-0053, Emergency & Transient Response, Attachment 13, Rev 22 Proposed references to be provided to applicants during examination: OSP-53, Attach. 13 p. 2 of 2 only Learning Objective:
RLP-STM-0201, Standby Liquid Control, Obj 1 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 34 QUESTION 34 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
211000 A2.03 IR 3.2 Ability to (a) predict the impacts of the following on the STANDBY LIQUID CONTROL SYSTEM ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: A.C. power failures Proposed Question:
Following a LOSS of RSS #1 Plant conditions are as follows:
All control rods did not insert Reactor power is 38%
Division 1 DG started but tripped Division 2 DG is in standby Division 3 DG is running supplying its bus Which of the following is a correct statement with regard to SLC operation?
A. SLC injection is required using SLC Pump A B. SLC injection is required using SLC Pump B C. EOP-0005 Enclosure 15 for alternate SLC is required D. SLC injection is not required Proposed Answer:
B Explanation A. No power is available to SLC pump A B. Correct - 38% power exceeds the drain and bypass valve capacity so SLC injection is required; power is only available to Div 2 (SLC pump B)
C. Power is available to SLC pump B, Alternate SLC injection is not warranted.
D. See B Technical Reference(s):
R-STM-0201, SLC, Rev 7 pp. 22,32 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-513, Obj 3 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 35 QUESTION 35 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
212000 A3.06 IR 4.2 Ability to monitor automatic operations of the REACTOR PROTECTION SYSTEM including: Main turbine trip: Plant-Specific Proposed Question:
Following a main turbine trip from 100% power, the reactor will scram first on which of the following signals?
A. Low water level due to shrink B. High pressure due to control valve closure C. High neutron flux due to pressure rise D. Turbine stop valve position Proposed Answer:
D Explanation A. See D B. See D C. See D D. Correct - This scram anticipates the rise in reactor pressure, neutron flux and heat flux resulting from the loss of heat sink on a turbine trip Technical Reference(s):
R-STM-0508, RPS, Rev 6 p. 47 of 59 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0508, Obj 2 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.6 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 36 QUESTION 36 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
215003 A4.05 IR 3.4 Ability to manually operate and/or monitor in the control room: Trip bypasses Proposed Question:
A plant startup is in progress. Reactor power is on range 5 of the IRMs.
IRM-F amplifier card fails, causing an INOP condition on IRM-F and a 1/2 Scram.
The CRS directs you to bypass IRM-F and reset the 1/2 Scram.
To bypass the IRM you should:
A. Rotate the IRM draw mode switch to the STANDBY position B. Fully withdraw IRM-F and down range to range 1 C. Rotate the IRM draw mode switch to the TRIP/TEST position D. Place the IRM bypass Select Switch to the IRM-F position Proposed Answer:
D Explanation A. Rotating this switch to standby generates an INOP condition for the IRM and does not change the status B. This will only bypass the IRM if the reactor mode switch is in RUN C. See A D. Correct - This is the only method for the control room operator to bypass IRM-F in these conditions Technical Reference(s):
SOP-0074, Neutron Monitoring, Rev 306 R-STM-0503, Neutron Monitoring, Rev 8 p. 42 of 112 Proposed references to be provided to applicants during examination:
None Learning Objective:
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.2 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 37 QUESTION 37 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
215004 K2.01 IR 2.6 Knowledge of electrical power supplies to the following: SRM channels/detectors Proposed Question:
The power supply to SRM C detector is ___.
A. RPS A B. RPS B C. VBS-PNL01A1 D. VBS-PNL01B1 Proposed Answer:
C Explanation A. Correct - RPS A is the power supply to SRM A & C B. RPS B is the power supply to SRM B & D C. VBS-PNL01A1 is the power supply to neutron monitoring recorders D. VBS-PNL01B1 is the power supply to neutron monitoring recorders Technical Reference(s):
R-STM-0503, Neutron Monitoring, Rev 8 p.84 of 112 Proposed references to be provided to applicants during examination:
None Learning Objective:
R-STM-0503, Obj 7 Question Source:
Modified Bank #
Nov 2010 Audit Q#36 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.2 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 38 QUESTION 38 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
215004 G2.4.4 IR 4.5 Knowledge of annunciator alarms, indications, or response procedures. SRMs Proposed Question:
During a reactor startup, the ATC has been withdrawing SRMs in accordance with GOP-0001, Plant Startup. All SRMs except C indicate full out; SRM C is reading offscale high and indicates driving out. The following alarm is in:
SRM UPSCALE OR INOPERATIVE Which of the following additional conditions will initiate a Control Rod Withdraw Block?
A. Mode switch in RUN and all IRMs on Range 8 B. Mode switch in STARTUP/HOT STBY and all IRMs on Range 7 C. Mode switch in STARTUP/HOT STBY and SRM C Bypassed D. Mode switch in RUN and SRM C Selector switch in Standby Proposed Answer:
B Explanation A. and D. The rod withdrawal block is bypassed when the mode switch in run B. Correct-If IRMs are not on Range 8 or above in Mode 2, an SRM UPSC or INOP initiates a rod withdrawal block.
C. The rod withdrawal block is bypassed when the affected SRM is bypassed Technical Reference(s):
ARP-P680-05-C05 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0503, Obj 5,7 Question Source:
Modified Bank # RBS-NRC-53 Question History:
Last NRC Exam NA (original question was on the 1997 NRC exam)
Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.6 Comments: Rejected KA: There is no AOP or EOP entry conditions having to do with SRMs.
The only G2.4 category applicable to SRMs is G2.4.31
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 39 QUESTION 39 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
215005 K1.09 IR 3.6 Knowledge of the physical connections and/or cause-effect relationships between AVERAGE POWER RANGE MONITOR/LOCAL POWER RANGE MONITOR SYSTEM and the following: Reactor recirculation system: BWR-5,6 Proposed Question:
Core flow rate is provided to the APRMs for use by the flow control trip reference cards to establish control rod withdrawal blocks and scram trip setpoints, this flow rate is obtained from which of the following sources?
A. the calibrated jet pumps B. the above and below core plate differential pressure C. the elbow taps on both recirculation loops D. the steam flow feed flow differential summer Proposed Answer:
C Explanation A. See C B. See C C. Correct-A d/p signal is provided to the APRMs from elbow taps on both recirculation loops D. See C Technical Reference(s):
R-STM-0503, Neutron Monitoring, Rev 7 p. 60 of 112 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0503, Obj 27 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.2 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 40 QUESTION 40 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
217000 K2.01 IR 2.8 Knowledge of electrical power supplies to the following: Motor operated valves Proposed Question:
The normal power supply to E51-F063, RCIC STEAM SUPPLY INBD ISOL VALVE is A. EHS-MCC2L B. EHS-MCC2D C. ENB-MCC1 D. BYS-SWG01B Proposed Answer:
B Explanation A. EHS-MCC2L is an alternate source of power to E51-F063 utilized for AOP-0031 B. Correct-EHS-MCC2D is the normal power source to E51-F063 C. DC supply ENB-MCC1 is the source of power to many E51 MOVs but NOT to E51-F063 D. DC supply BYS-SWG01B is the source of power to the RCIC gland seal compressor NOT to E51-F063 Technical Reference(s):
R-STM-0209, RCIC, Rev 10 p. 42 of 52 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0209, Obj 13 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.8 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 41 QUESTION 41 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
218000 K3.02 IR 4.5 Knowledge of the effect that a loss or malfunction of the AUTOMATIC DEPRESSURIZATION SYSTEM will have on following: Ability to rapidly depressurize the reactor Proposed Question:
The plant is operating in the Emergency Operating Procedures following a significant transient. During the transient, a short resulted in the loss of ENB-PNL02A.
Plant conditions require Emergency Depressurization per the Emergency Operating Procedures.
Which of the following represents the method that should be used to accomplish Emergency Depressurization?
A. At H13-P601, open 7 ADS/SRVs.
B. At H13-P631, open 7 ADS/SRVs.
C. Arm and depress the Division 1 ADS Manual Initiate pushbuttons.
D. Alternate depressurization methods listed in the EOPs should be utilized due to SRV failure.
Proposed Answer:
B.
Explanation:
A. Loss of power to ENB-PNL02A prevents use of Div 1 SRV solenoids; the switches on P601 are Div 1.
B. Correct - Div 2 solenoids are still available to open the SRVs.
C. Div 1 solenoids are de-energized.
D. This would only be required if SRVs could not be opened. Div 2 solenoids are still available.
Technical Reference(s):
R-STM-0202, ADS, Rev 2 pp. 20,21 of 36 R-STM-0109, Main Steam, Rev 13 p. 12 of 95 Proposed references to be provided to applicants during examination:
None Learning Objective:
R-STM-0202 Obj. 6,12 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41b.3 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 42 QUESTION 42 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
218000 A4.02 IR 4.2 Ability to manually operate and/or monitor in the control room: ADS logic initiation Proposed Question:
The plant has scrammed due to a loss of offsite power.
Neither HPCS nor RCIC will start.
Approximately 5 minutes later, RPV water level decreases below -143 inches, the DIV 2 ADS LOGIC TIMER INITIATED annunciator illuminates.
The Unit Operator is directed to INHIBIT ADS per EOP-0001.
Later the Operator ARMS and Depresses the ADS B MANUAL INITIATION pushbuttons.
What is the response of the ADS System in this situation?
ADS will initiate:
A. immediately, if any Div 2 low pressure ECCS subsystem pressure permissive is satisfied.
B. in 105 seconds, if any Div 2 low pressure subsystem pressure permissive is satisfied.
C. immediately, regardless of low pressure ECCS subsystem status.
D. In 105 seconds, regardless of low pressure ECCS subsystem status.
Proposed Answer:
A Explanation A. Correct-ADS Logic only requires subsystem pressure permissive prior to manual initiation B. See A C. See A D. See A Technical Reference(s):
R-STM-0202, ADS, Rev 2 p.38 of 41 (Figure 2)
Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0202, Obj 7 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.8 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 43 QUESTION 43 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
223002 K4.01 IR 3.0 Knowledge of PRIMARY CONTAINMENT ISOLATION SYSTEM/NUCLEAR STEAM SUPPLY SHUT-OFF design feature(s) and/or interlocks which provide for the following: Redundancy Proposed Question:
Why do systems penetrating containment which are part of the reactor coolant boundary have redundant isolation valves?
A. To allow one valve to be removed from service for maintenance activities.
B. To ensure that multiple failure will not prevent at least a single valve isolation of the process line C. To allow for manual isolation from the control room in case the automatic isolation does not work D. To ensure that a single failure will not prevent at least a single valve isolation of the process line.
Proposed Answer:
D Explanation A. See D B. Multiple failures could still prevent penetration isolation C. Both valves must be automatic isolations per design criteria D. Correct-10CFR50, General Design Criteria 55 Technical Reference(s):
R-STM-0058, CRVICS, Rev 9 p. 5 of 63 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0058, Obj 11 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.3 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 44 QUESTION 44 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
239002 K5.04 IR 3.3 Knowledge of the operational implications of the following concepts as they apply to RELIEF/SAFETY VALVES : Tail pipe temperature monitoring Proposed Question:
The plant had been operating at 100% power when a severe over-pressure transient resulted in ALL Safety Relief Valves (SRV) opening in the "relief" mode.
RPV pressure peaked at 1200 psig Current reactor pressure is 500 psig and lowering One SRV remains stuck open Which of the following describes the resulting tailpipe temperature trend as the plant cools down and depressurizes through the stuck open SRV? (Assume containment pressure is 0 psig and remains constant.)
SRV tailpipe temperature will ___ and will then slowly fall, following reactor pressure during the depressurization below 500 psig.
A. Start at 285°F, currently 280°F B. Start at 285°F, currently 330°F C. Start at 330°F, currently 280°F D. Start at 330°F, currently 320°F Proposed Answer:
B Explanation A, Correct starting point, however tail pipe temperature will rise to 330ºF as pressure falls.
B. Correct - At onset of this event the tail pipe temperature would be 285ºF ( the isentropic value for 1200 psig and ~25 psia)(14.7 plus 10 feet of water over the tail pipe quencher). Tail pipe temperature will rise to 330ºF as pressure falls to 500 psig.
C and D cannot be true due to temperature dropping Technical Reference(s):
HLO-168 Steam Tables Proposed references to be provided to applicants during examination:
Mollier Diagram (large)
Learning Objective:
Question Source:
Modified Bank # RBS-NRC-459 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.14 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 45 QUESTION 45 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
259002 K6.03 IR 3.1 Knowledge of the effect that a loss or malfunction of the following will have on the REACTOR WATER LEVEL CONTROL SYSTEM : Main steam flow input Proposed Question:
While operating at 100% power, the C Main Steam Line flow transmitter fails low.
What is the expected response of the Feedwater level control system with no operator actions taken?
A. RPV level will lower until it reaches Level 3 and the reactor scrams.
B. RPV level will lower and stabilize at a new lower level above Level 3.
C. RPV level will rise and stabilize at a new higher level below Level 8.
D. RPV level will rise until it reaches Level 8 and the reactor scrams.
Proposed Answer:
B Explanation A. Only first part is correct; see B B. Correct - A loss of 1 out of 4 steam flow transmitters results in a sensed reduction in steam flow of 25%;
this sensed reduction will cause the FWLC system to close the Feed Reg Valves and consequently RPV level will lower. Level will stabilize below its normal level (but above the Level 3 scram setpoint) because the FWLC system is level dominant.
C. This is the expected response for a single steam line transmitter failing high D. This is the expected response for a single feed flow transmitter failing low Technical Reference(s):
R-STM-0107, Feedwater, Rev 27 p. 71 of 105 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0107, Obj B14 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.4 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 46 QUESTION 46 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
261000 A1.01 IR 2.9 Ability to predict and/or monitor changes in parameters associated with operating the STANDBY GAS TREATMENT SYSTEM controls including: System flow Proposed Question:
A leak has occurred in the Drywell and Drywell pressure is 2.14 psid and stable. Both trains of Standby Gas Treatment (GTS) started and consequently OSP-0053 Hard Card 1, Operating Auxiliary Building Ventilation was used to reduce to one train of SBGT running; GTS-A is running. Subsequently, a loss RSS#1 occurred and the Div 1 Diesel Generator failed to start.
What is the status of GTS-B following the loss of RSS#1?
A. GTS-B may only be started in High Volume Purge mode due to power failure.
B. GTS-B must be manually initiated due to manually securing.
C. GTS-B will restart automatically due to low flow in GTS-A.
D. GTS-B will restart automatically due to undervoltage trip of GTS-A.
Proposed Answer:
C Explanation A. Power is only lost to Div 1; Div 2 is still available B. Securing per the hard card places GTS-B in standby; C. Correct - DW 1.68 is still locked in, so when low flow occurs in Div 1 due to the loss of power, then the Div 2 will automatically restart.
D. The interlock that will start GTS-B is low flow in the running GTS; not undervoltage.
Technical Reference(s):
R-STM-0257, Standby Gas Treatment, Rev 5 p. 15 of 28 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0257, Obj 5,12 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 47 QUESTION 47 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
262001 A2.11 IR 3.2 Ability to (a) predict the impacts of the following on the A.C. ELECTRICAL DISTRIBUTION ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:
Degraded system voltages Proposed Question:
The plant is operating at 100% power when alarm P808-86A, Grid Trouble is received.
SPI-REC102 on P808 indicates 230 KV system voltage at Fancy Point to be 223.3 KV.
The SOC contacts the control room and indicates that a transient has occurred and Fancy Point stability cannot be determined at this time.
The synchroscope for Division I D/G is indicating erratically.
(1) What is the impact to plant equipment?
(2) What actions should be taken to mitigate this event?
A. (1) Amps will increase on the running equipment.
(2) Perform a normal start of the D/G, parallel it to offsite power and disconnect the bus from the grid.
B. (1) Amps will increase on the running equipment.
(2) Perform an emergency start of the D/G and open the safety related bus supply breaker.
C. (1) Amps will decrease on the running equipment.
(2) Perform an emergency start of the D/G and open the safety related bus supply breaker.
D. (1) Amps will decrease on the running equipment.
(2) Perform a normal start of the D/G, parallel it to offsite power and disconnect the bus from the grid.
Proposed Answer:
B Explanation Plant indications show that Fancy Point is NOT stable(second note on page 64 of AOP-64)
A. Would be correct if Fancy Point was stable B. Correct per steps:5.5.3.1 and 5.5.3.4 C. and D. Running equipment amps will rise as voltage lowers. Normal voltage is 230KV the stem gives 223.3KV Technical Reference(s):
AOP-0064, Degraded Grid, Rev 6 p 8 of 11 Proposed references to be provided to applicants during examination:
AOP-0064 Degraded Grid, Rev 6 Learning Objective:
_________________________ (As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 4 10 CFR Part 55 Content: 55.41.b.5 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 48 QUESTION 48 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
262002 A3.01 IR 2.8 Ability to monitor automatic operations of the UNINTERRUPTABLE POWER SUPPLY (A.C./D.C.) including: Transfer from preferred to alternate source Proposed Question:
BYS-INV01A displays the following information:
Rectifier Output 0 amps Battery Output Normal at 135 VDC Inverter Output Normal at 122 VAC What is the status of the loads normally supplied by this inverter?
A. Loads are currently de-energized B. Loads are currently being supplied by the battery via the inverter C. Loads are currently being supplied by the normal AC source via the inverter D. Loads have automatically swapped to the alternate AC source Explanation A. The inverter output has power, so the loads have power B. Correct - The normal AC source is unavailable based on the rectifier output; output of the battery and inverter reveal that the battery is supplying power to the inverter and the inverter is powering the loads C. Rectifier output reveals that the normal AC power source is de-energized D. Alternate AC power source is provided through a Manual Bypass Switch (which has not been turned)
Proposed Answer:
B Technical Reference(s):
R-STM-0300, AC Electrical Distr., Rev 26 pp. 28-29 of 105 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0300, Obj 12 Question Source:
Bank #
RBS Nov 2008 Audit Q#49 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 49 QUESTION 49 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
263000 A4.01 IR 3.3 Ability to manually operate and/or monitor in the control room: Major breakers and control power fuses: Plant-Specific Proposed Question:
A breaker test is being performed on ENS-ACB03, E12-C002A RHR A PUMP breaker.
The breaker will be in the TEST position with control power fuses INSTALLED. The breaker will then be CLOSED.
Which of the following represents the expected control room light indications for the RHR Pump A breaker when the test conditions mentioned above are established?
A. Red light OFF, Green light OFF, White light OFF B. Red light OFF, Green light OFF, White light ON C. Red light ON, Green light OFF, White light OFF D. Red light ON, Green light OFF, White light ON Proposed Answer:
C Explanation A. B. and D. See C C. While in the test position the control room breaker indication for the red and green lights will be the same as the local indication however the white power available light will not be lite even with the control power fuses installed unless the breaker is in the connect position. All other combination of light indication s are incorrect Technical Reference(s):
OSP-0052, Breaker Racking, Rev 18 p Proposed references to be provided to applicants during examination:
None Learning Objective:
Not available Question Source:
Bank #
RBS-OPS-07756 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 50 QUESTION 50 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
264000 K1.05 IR 3.2 Knowledge of the physical connections and/or cause-effect relationships between EMERGENCY GENERATORS (DIESEL/JET) and the following: Emergency generator fuel oil supply system Proposed Question:
The correct fuel oil supply flowpath for operation of the Div 1 Standby Emergency Diesel Generator is from its associated storage tank through the _____, to the injectors.
A. fuel oil transfer pump, strainer, duplex filter, fuel oil day tank B. strainer, fuel oil transfer pump, fuel oil day tank, duplex filters C. strainer, fuel oil transfer pump, fuel oil day tank, booster pump D. fuel oil transfer pump, strainer, fuel oil day tank, booster pump Proposed Answer:
D Explanation A. the filter is located after the day tank B. the strainer is after the transfer pump C. the strainer is after the transfer pump D. Correct - The full flowpath of fuel oil is storage tank, transfer pump, day tank, duplex strainer, booster pump, duplex filter, injector pump, injectors Technical Reference(s):
R-STM-0309S, Rev 14, pp. 17 & 20 of 117 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0309S, Obj 2 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.8 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 51 QUESTION 51 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
264000 G2.1.31 IR 4.6 Ability to locate control room switches, controls, and indications, and to determine that they correctly reflect the desired plant lineup. Emergency Diesel Generators Proposed Question:
The Div 2 Emergency Diesel Generator is operating and tied to ENS-SWG 1B. The unit operator rotates the DG Voltage Regulator Control Switch to raise. Which indication shows the largest change (1) if offsite is paralleled to the bus, and (2) if offsite is NOT paralleled to the bus.
(1)
(2)
A. Reactive Load (KVAR)
Frequency (Hz)
B. Real Load (KW)
Voltage (VAC)
C. Reactive Load (KVAR)
Voltage (VAC)
D. Real Load (KW)
Frequency (Hz)
Proposed Answer:
C Explanation A. (1) is correct however, Frequency is controlled by the Vovernor control switch when not in parallel B. Generator load (KW) is adjusted with the Governor Control switch when the EDG is in parallel C. Correct - The voltage regulator control switch varies excitation current and will adjust generator reactive load when in parallel and adjusts voltage when not in parallel.
D. Generator load (KW) is adjusted with the Governor Control switch when the EDG is in parallel Technical Reference(s):
R-STM-0309S, Rev 13 pp. 43-44 of 117 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0309S, Obj 8 Question Source:
Modified Bank # RBS-OPS-3255 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 52 QUESTION 52 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
300000 K2.01 IR 2.8 Knowledge of electrical power supplies to the following: Instrument air compressor Proposed Question:
The Instrument air compressors A, B, and C are powered from ___, ___, and ___
respectively.
A. NJS-SWG 1G, 1H, and 1F B. NJS-SWG 1E, 1J, and 1K C. NHS-MCC 1L, 1M, and 1M D. NHS-MCC 1L, 1L, and 1M Proposed Answer:
A Explanation A. Correct-these are the power supplies to the IAS compressors B. these are the power supplies to the Service Air compressors C. these are the power supplies to the IAS trim coolers D. these are the power supplies to the SAS trim coolers Technical Reference(s):
R-STM-0121, Rev 16 p. 9 of 69 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0121, Obj 10 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.4 Comments: rejected KA K2.02; re-selected K2.01 - RBS has diesel operated emergency air compressor
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 53 QUESTION 53 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
400000 K3.01 IR 2.9 Knowledge of the effect that a loss or malfunction of the CCWS will have on the following: Loads cooled by CCWS Proposed Question:
The Division 2 isolation valves in the Reactor Plant Component Cooling Water System (CCP) have closed on a 56 psig isolation signal.
What equipment is still receiving cooling water from the CCP system?
A. Recirc pumps, RWCU NRHXs, RWCU pumps B. RWCU pumps, RHR Pump A Seal Coolers, RWCU NRHXs C. RWCU pumps, Reactor Plant Sampling panel, Fuel Pool Cooler 1A D. Recirc pumps, RHR Pump A Seal Coolers, Reactor Plant Sampling panel Proposed Answer:
A Explanation A. Correct - The Safety loop isolates which secures cooling to the RHR Pump Seal Coolers, Fuel pool coolers, and CRD pumps. Cooling is not isolated to the three loads listed.
B. RHR Pump Seal Coolers (both divisions) are isolated as part of the safety loop C. Fuel Pool Coolers (both divisions) are isolated as part of the safety loop D. RHR Pump Seal Coolers (both divisions) are isolated as part of the safety loop Technical Reference(s):
R-STM-0115, Rev 6 pp. 12-14 of 35 and Figure 1 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0115, Obj 4,8,11 Question Source:
Bank #
RBS-OPS-1789 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 54 QUESTION 54 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
201003 A4.02 IR 3.5 Ability to manually operate and/or monitor in the control room: CRD mechanism position: Plant-Specific Proposed Question:
The ATC operator just selected a control rod to move in accordance with an approved reactivity maneuver plan when the Control Rod Withdrawal Block Alarm annunciates.
The RC & IS Operator Control Module (OCM) also displays the following:
- DATA FAULT pushbutton is backlit
- CHANNEL DISAGREE is backlit The rod position displayed on the full core display for the selected rod is flashing alternately between 08 and - -.
What operator action would allow this rod to be moved?
A. Isolating the rod electrically within the Rod Gang Drive Cabinet B. Depressing the DATA MODE pushbutton on the OCM C. Depressing the DATA SOURCE pushbutton on the OCM D. Depressing the ENTER SUBST pushbutton on the OCM Proposed Answer:
D Explanation A. Electrically isolating the rod in RGDC will prevent rod movement; bypassing the rod in RACS (Rod Action Control System would allow rod movement.
B. This pushbutton works in conjunction with the Data Source pushbutton to allow you to choose either single channel or alternating channel(s) to display on the full core display; this would make the alternating rod position indication to stop, but not clear the rod block.
C. This pushbutton allows you to choose which of the the 2 channels to display on the full core display; pushing this button would show first one channel then pushing it again would show the other.
D. Correct - This pushbutton forces the single channel of bad data to be replaced with the other channels good data; thereby allowing rod movement.
Technical Reference(s):
R-STM-0500, Rev 3 pp. 19-25 of 46; SOP-0071, Rev 29, Section 5.12 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0500, Obj 7,9 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.6 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 55 QUESTION 55 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
201005 A1.01 IR 3.2 Ability to predict and/or monitor changes in parameters associated with operating the ROD CONTROL AND INFORMATION SYSTEM (RCIS) controls including: First stage shell pressure/turbine load: BWR-6 Proposed Question:
Given the following plant conditions:
- Reactor power 45%
- Generator load 480 MWe Power ascension is in progress. The next step of the Reactivity Maneuvering Plan is to select and continuously withdraw control rod 28-49 from position 12 to position 24.
Just prior to withdrawing the rod, the Main Turbine First Stage Shell Pressure transmitter output signal fails upscale.
When the withdraw button is pushed, control rod 28-49 will ___.
A. remain at position 12 B. withdraw to position 16 and settle C. withdraw to position 20 and settle D. withdraw to position 24 and settle Proposed Answer:
B Explanation A. If turbine first stage shell pressure was indicating failed low, the Rod Pattern Controller logic would be enabled and could cause a rod withdraw blow (depending on the current rod pattern)
B. Correct-the rod withdrawal limitations are dependent on reactor power as sensed by First Stage Shell Pressure. An upscale failure would indicate reactor power above the high power setpoint to RC&IS. The Rod Withdrawal Limiter will then limit rod withdrawals to 2 notches (12-16).
C. See B D. See B Technical Reference(s):
R-STM-0500, Rev 3 p.16 of 46 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0500, Obj 22 Question Source:
Bank #
RBS-NRC-665 Question History:
Last NRC Exam Dec 2008 Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.6 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 56 QUESTION 56 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
202001 K4.02 IR 3.1 Knowledge of RECIRCULATION System design feature(s) and/or interlocks which provide for the following: Adequate recirculation pump NPSH Proposed Question:
When total Feedwater flow drops below the Reactor Recirc system interlock level, the Reactor Recirc Pumps downshift from fast speed to slow speed. This interlock ___.
A. prevents flow velocity effects on the wide range level indication.
B. prevents thermal stress on the Recirc pump C. prevents cavitation in the Recirc pumps D. adds negative reactivity in anticipation of an imminent reactor scram Proposed Answer:
C Explanation A. the interlock associated with wide range flow velocity effects is the low reactor level interlock B. the interlock associated with thermal stress is the Steam Dome to Vessel Bottom Head delta T C. Correct - Cavitation is prevented by inhibiting high speed operation of pumps with feed flow < 19.9%
D. the EOC-RPT interlock anticipates a reactor scram based on a turbine trip causing a pressure transient, which will rapidly add positive reactivity.
Technical Reference(s):
R-STM-0053, Rev 13 p. 27 of 76 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0053, Obj 17 Question Source:
Modified Bank # RBS-NRC-168 Question History:
Last NRC Exam 1995 Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.2 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 57 QUESTION 57 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
202002 K1.09 IR 3.1 Knowledge of the physical connections and/or cause-effect relationships between RECIRCULATION FLOW CONTROL SYSTEM and the following: Reactor water level Proposed Question:
The plant is operating at 100% power. The A narrow range level channel is selected as the input to the Feedwater Level Control System. A leak has developed in the reference leg of the A narrow range level transmitter.
The ATC operator promptly placed the Master Feedwater Level Controller in MANUAL.
As a result of this condition, both Recirc pumps will ___.
A. remain at their present speed, and the Recirc Flow Control Valves will runback to 60% drive flow position.
B. transfer to SLOW speed operation, and the Recirc Flow Control Valves will remain at their present position.
C. transfer to SLOW speed operation, and the Recirc Flow Control Valves will runback to 60% drive flow position.
D. remain at their present speed, and the Recirc Flow Control Valves will remain at their present position.
Proposed Answer:
D Explanation A. first part is correct, but the reference leg leak will cause a false high level indication; FCVs will not runback due to a high level B. and C. The reference leg leak will cause a false high level indication, Recirc pumps will not downshift due to a high RPV level.
D. Correct - Recirc Pumps and FCVs logic receive level signal from the narrow range selected (A); the reference leg leak will cause transmitter differential pressure to rise, therefore the Recirc system will not receive a low RPV level (Recirc pumps downshift at level 3 and FCVs runback at level 4)
Technical Reference(s):
R-STM-0107B, Rev 27 pp. 58-59 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0107B, Obj 10 Question Source:
Bank #
Dec 2008 NRC Exam Q#57 Question History:
Last NRC Exam Dec 2008 Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.2 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 58 QUESTION 58 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
216000 K6.01 IR 3.1 Knowledge of the effect that a loss or malfunction of the following will have on the NUCLEAR BOILER INSTRUMENTATION: A.C. electrical distribution Proposed Question:
A loss of RPS Bus A causes which RPV level indication on the 680 panel to fail downscale?
A. B21-R604, Wide Range meter B. C33-R606A, Narrow Range Channel A meter C. C33-R608B, Narrow Range recorder D. C33-R608R, Upset Range recorder Proposed Answer:
A Explanation A. Correct - power supply to the wide range meter comes from RPS -A and fails downscale B. power supplied by inverter 1VBN-PNL01B1 C. power supplied by inverter 1VBN-PNL01B1 D. The narrow range/upset range recorder has a single power supply (1VBN-PNL01B1)
Technical Reference(s):
R-STM-0051, Rev 5 p. 23 of 47 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0051, Obj 13; RLP-STM-0508, Obj 7 Question Source:
Bank #
RBS-NRC-808 Question History:
Last NRC Exam Feb 2003 Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 59 QUESTION 59 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
219000 K2.02 IR 3.1 Knowledge of electrical power supplies to the following: Pumps (RHR-Supp Pool Cooling)
Proposed Question:
The electrical power supplies to (1) RHR Pump C, and (2) its associated line fill pump is
___ and ___.
A. (1) ENS-SWG1A ; (2) ENS-SWG1A B. (1) ENS-SWG1B ; (2) EJS-SWG1A C. (1) ENS-SWG1B ; (2) EJS-SWG1B D. (1) ENS-SWG1A ; (2) ENS-SWG1B Proposed Answer:
C Explanation A. Both part 1 and 2 are incorrect; See C B. First part is correct; See C for part 2 C. Correct - RHR pumps B & C power supply is ENS-SWG1B; the line fill pump for Div 2 is EJS-SWG1B D. Part 1 is incorrect; See C Technical Reference(s):
R-STM-0204, p. 25 of 63 ; EE-001AC Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0204, Obj 11 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.8 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 60 QUESTION 60 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
223001 G2.1.28 IR 4.1 Knowledge of the purpose and function of major system components and controls. Primary Containment Systems Proposed Question:
The function of the ___ System is to control hydrogen concentration that would be generated during a Design Basis Accident. If hydrogen is detected in the drywell or containment, proper operation of this system alone is sufficient to consume the hydrogen being generated.
A. Containment Hydrogen Purge B. Hydrogen Igniter C. Hydrogen Mixing D. Hydrogen Recombiner Proposed Answer:
B Explanation A. This system designed as a backup to the H2 Recombiners; there is no EOP/SAP guidance for its use B. Correct - The H2 igniters are designed to handle 75% of the Metal-Water Reaction rate; they are designed to mitigate the consequences of a generation event more severe than a design basis LOCA.
The Igniter system bounds the DBA scenario used in sizing the H2 Mixing and H2 Recombiner Systems.
C. Primary function is to mix containment and drywell atmospheres thereby temporarily diluting the H2 D. Recombiners are started 14 days after a DBA Technical Reference(s):
EOP Bases, Rev 16, p. B-8-30, 31 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0057, Obj 20 Question Source:
Modified Bank # RBS-OPS-06288 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.9 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 61 QUESTION 61 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
239001 K3.15 IR 3.5 Knowledge of the effect that a loss or malfunction of the MAIN AND REHEAT STEAM SYSTEM will have on following:
Reactor water level control Proposed Question:
The plant is operating at 70% reactor power when one inboard MSIV fails closed.
RPV level will ___.
A. (1) increase and stabilize at a higher level.
B. (1) decrease and stabilize at a lower level.
C. (1) decrease and then return to normal level.
D. (1) increase and then return to normal level.
Proposed Answer:
C Explanation A. RPV level indication measures water level in the downcomer region and due to steam flow across the dryers, level is approximately 7 inches higher in the downcomer than the core. When an MSIV closes, pressure will go up momentarily and concurrently collapse some of the steam void in the core. Water levels equalize and then FWLC will compensate and get level back to the the setpoint on the tape set B. First part is correct, but RPV level is being controlled by FWLC system and will return to whatever the tape set is dialed to (setpoint setdown is not activated)
C. Correct - RPV level initially drops due to a pressure transient causing voids to collapse; water from downcomer flows into the core and then FWLC compensates and level returns to normal.
D. See A Technical Reference(s):
RPPT-HLO-0316, Slide 46 of 72 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0109, Obj 2, 19; RLP-HLO-0316, Obj 1, 2 Question Source:
Bank #
RBS-NRC-308 Question History:
Last NRC Exam June 1995 Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.5 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 62 QUESTION 62 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
241000 A2.01 IR 3.5 Ability to (a) predict the impacts of the following on the REACTOR/TURBINE PRESSURE REGULATING SYSTEM ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Loss of turbine inlet pressure signal Proposed Question:
The plant is starting up and reactor power is currently 8%. EHC Pressure Regulator Channel A is selected for pressure control. Pressure Regulator Channel B is in TEST.
If the Averaging Manifold Pressure transmitter for Pressure Regulator Channel A fails to 0 psig, the Turbine Control Valves will __(1)__ and the steam Bypass Valves __(2)__.
A. (1) fully open; (2) remain closed B. (1) fully close; (2) fully open C. (1) fully close; (2) remain closed D. (1) fully open; (2) fully open Proposed Answer:
C Explanation A. The pressure regulator sensing a low pressure, will close (not open) the TCVs trying to raise pressure.
B. TCVs will close causing pressure to rise, but the BPVs use the same pressure transmitter and therefore would remain closed (not open).
C. Correct - Turbine Control Valves will close and the BPVs use the same pressure transmitter and therefore would also remain closed D. The pressure regulator sensing a low pressure, will close (not open) the TCVs trying to raise pressure Technical Reference(s):
R-STM-0509, Rev 14 p.51 of 81 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0509, Obj 10 Question Source:
Modified Bank # RBS-LOR-1252 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.5 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 63 QUESTION 63 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
272000 K4.02 IR 3.7 Knowledge of RADIATION MONITORING System design feature(s) and/or interlocks which provide for the following:
Automatic actions to contain the radioactive release in the event that the predetermined release rates are exceeded Proposed Question:
The plant is operating at 100% power. Annulus Pressure Control system is in operation with HVR-FN16A, Annulus Pressure Control (APC) Fan A running.
RMS-RE11A, Div 1 Annulus Exhaust Radiation Monitor goes into High Alarm (reading greater than 3.89E-5 µci/cc). Which of the following describes the ventilation lineup after this event?
A. HVR-FN16A trips; Both Standby Gas Treatment Trains are running B. HVR-FN16A stays running; Both Standby Gas Treatment Trains are running C. HVR-FN16A stays running; ONLY Standby Gas Treatment Train A is running D. HVR-FN16A trips; ONLY Standby Gas Treatment Train A is running Proposed Answer:
A Explanation A. Correct - RMS-RE11A sends a signal to trip FN16A and start GTS-FNA; GTS-FNB will start due to a low APC System flow B. RMS-RE11A sends a signal to trip FN16A C. RMS-RE11A sends a signal to trip FN16A D. Part 1 is correct; Part 2 is wrong because GTS-FNB will start due to a low APC System flow Technical Reference(s):
ARP-DSPL230-1GP011, Rev 9 R-STM-0511, Radiation Monitoring, Rev 15 p. 46 of 48 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0511, Obj 4,6 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.11 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 64 QUESTION 64 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
288000 A3.01 IR 3.8 Ability to monitor automatic operations of the PLANT VENTILATION SYSTEMS including: Isolation/initiation signals Proposed Question:
Containment Unit Coolers 1A and 1B are running.
Which of the following signals will cause (1) chilled water to the Containment Unit Coolers to isolate, and (2) Service Water to the Containment Unit Coolers to align?
A. (1) High Negative D/P between Containment and Annulus (greater than -12) ;
(2) RPV level 2 (-43)
B. (1) High Drywell D/P (1.68) ;
(2) RPV level 1 (-143) after 60 sec time delay C. (1) RPV level 1 (-143) ; (2) RPV level 1 (-143) after 60 sec time delay D. (1) RPV level 2 (-43) ; (2) RPV level 2 (-43)
Proposed Answer:
B Explanation A. Part 1 is correct ; SW aligns on RPV level 1 after 60 time delay B. Correct - chill water isolates on RPV level2, DW D/P, and -12; Service Water does not align until level 1 is reached and then after a time delay of 60 seconds to allow separation between CW and SW.
C. Part 1 is incorrect - Level 2 signal isolates CW; D. Part 1 is correct ; SW aligns on RPV level 1 after 60 time delay Technical Reference(s):
R-STM-0403, Reactor Building HVAC, Rev 8 pp. 7-11 of 50 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0403, Obj 6 Question Source:
Modified Bank #
RBS-OPS-2307 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.7 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 65 QUESTION 65 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
290003 K5.01 IR 3.2 Knowledge of the operational implications of the following concepts as they apply to CONTROL ROOM HVAC: Airborne contamination (e.g., radiological, toxic gas, smoke) control Proposed Question:
A high-high radiation condition has been detected by RMS-RE13A and 13B, Main Control Room Local Intake A and B.
Which of the following represents the effect on the Control Building HVAC system?
HVC-MOV1A/B HVC-AOD19C/D/E/F CR AHU Outside Supply HVC Local Air Intake A.
OPEN OPEN B.
OPEN CLOSE C.
CLOSE OPEN D.
CLOSE CLOSE Proposed Answer:
C Explanation A high-high rad detected by RMS-RE13 will cause the following: HVC-MOV1 to close, HVC-AOD19s to open, and HVC-FN1 to start, Making C correct.
Technical Reference(s):
ARP-P863-74A-H03 and -H08, Rev 24 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0402, Obj 7 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.11 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 66 QUESTION 66 Rev 0 Examination Outline Cross-
Reference:
G2.1.7 IR 4.4 Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation Proposed Question:
OSP-0053, Emergency and Transient Response Support Procedure, contains Post-Scram Level Control Strategies.
In non-ATWS conditions, when MSIVs are closed, the prescribed level band is _(1)_.
In an ATWS condition, with Reactor power at 30% and the Turbine on-line, the prescribed level band is _(2)_.
A. (1) 10 to 51 inches; (2) -60 to -140 inches B. (1) -20 to 51 inches; (2) -100 to -140 inches C. (1) 10 to 51 inches; (2) -100 to -140 inches D. (1) -20 to 51 inches; (2) -60 to -140 inches Proposed Answer:
D Explanation A. Part one would only be correct if MSIVs were open B. Part 1 is correct, part two would be correct if SRVs were required for pressure control C. see A D. Correct - The prescribed level band for a non-ATWS condition is normally 10 to 51, except when certain plant conditions described in the EOP bases are present. One such condition is closure of MSIVs where the expanded band is prescribed. In an ATWS when conditions are not present that would challenge containment (SRVs are not required for pressure control), then the level control band should remain -60 to -100 inches.
Technical Reference(s):
OSP-0053, Rev 22 pp. 16-19 of 74 EOP Bases pp. B-6-12 & -13; B-7-21 & -22 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-OPS-0512, Obj 5 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 67 QUESTION 67 Rev 0 Examination Outline Cross-
Reference:
G2.1.31 IR 4.6 Ability to locate control room switches, controls, and indications, and to determine that they correctly reflect the desired plant lineup Proposed Question:
The main turbine has just tripped while operating at 40% power.
The operator will see ___.
A. all 8 Scram Pilot Solenoid Valve indicating lights out on H13-P691.
B. Turbine Bypass Valves indicating open on H13-P680.
C. ENS-SWG1A aligned to NNS -SWG1B on H13-P808.
D. the main generator output breakers tripped and the exciter field breaker closed on H13-P680.
Proposed Answer:
B.
Explanation:
A. The 8 scram pilot lights are on H13-P680. P691 contains the RPS trip unit that input to the trip logic.
B. Correct-Bypass valve indications are on H13-P680 and they would be open as a result of the turbine trip.
C. ENS-SWG1A is normally aligned to NNS-SWG1A. This transient would not change that lineup.
D. Exciter field breaker would also be tripped for this transient.
Technical Reference(s):
AOP-0001, Reactor Scram, Rev 28 p. 4 of 10; AOP-0002, Turbine Trip, Rev 26 p. 6 of 10 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0310 Obj. 8 Question Source:
Bank #
RBS-NRC-01183 Question History:
Last NRC Exam RBS Dec. 2010 Q# 67 Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41b.4 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 68 QUESTION 68 Rev 0 Examination Outline Cross-
Reference:
G2.1.40 IR 2.8 Knowledge of refueling administrative requirements Proposed Question:
During refueling activities, Main Control Room personnel are required to maintain constant communication with the ___.
A. Fuel Movement Supervisor B. Bridge Driver/Fuel Handler C. IFTS Operator D. Refuel Senior Reactor Operator Proposed Answer:
D Explanation: Required by FHP-0003, Roles and Responsibilities of Refuel SRO Step 2.1 Technical Reference(s):
TR 3.9.11, Communications during core alts EN-FAP-OU-108, Fuel Handling Process, Rev 5 pp. 3,4 of 39 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-OPS-0410, Obj 1 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 4 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 69 QUESTION 69 Rev 0 Examination Outline Cross-
Reference:
G2.2.6 IR 3.0 Knowledge of the process for making changes to procedures Proposed Question:
In accordance with RBNP-001, DEVELOPMENT AND CONTROL OF RBS PROCEDURES, a Comment PAR, may be used for which of the following?
A. To make minor changes that result in a change of intent.
B. To correct typographical errors to a procedure that is being implemented.
C. To make suggestions for future procedure improvements.
D. To change acceptance criteria.
Proposed Answer:
C Explanation A. A procedure Revision is required for changes that result in a change of intent.
B. This requires an Editorial change.
C. Correct - This choice describes a Comment.
D. A change in acceptance criteria also results in a change of intent, so would require a Revision Technical Reference(s):
RBNP-001, Development and Control of Procedures, Rev 35 p. 19 of 43 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-0202, Obj 1 Question Source:
Bank # RBS-OPS-1667 Question History:
Last NRC Exam RBS April 2010 Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 70 QUESTION 70 Rev 0 Examination Outline Cross-
Reference:
G2.2.14 IR 3.9 Knowledge of the process for controlling equipment configuration or status Proposed Question:
A decon technician has called the RO requesting permission to open an MWS supply valve to obtain water for deconning purposes. What action is required?
A. The RO can authorize the manipulation and logging is not required as long as the tech calls back before the end of shift stating that the valve is closed B. The OSM/CRS must authorize the manipulation and it must be logged in the control room log or manipulated device log book.
C. The RO can authorize the manipulation and it must be logged in the control room log or manipulated device log book D. The OSM/CRS must authorize the manipulation and logging is not required as long as the tech calls back before the end of shift stating that the valve is closed.
Proposed Answer:
B Explanation A. See B B. Correct OSP-0014 requires OSM/CRS approval and logging for configuration control purposes when manipulating plant components outside of procedures C. See B D. See B Technical Reference(s):
OSP-0014, Administrative Control of Equipment, Rev 304 p. 6 of 16 Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 71 QUESTION 71 Rev 0 Examination Outline Cross-
Reference:
G2.2.35 IR 3.6 Ability to determine Technical Specification Mode of Operation Proposed Question:
The following plant conditions exist:
Reactor Coolant temperature is 115F The mode switch position is Shutdown Refueling operations have been completed and the last head bolt has been tensioned What mode of operation is the plant in?
A. Mode 2 Startup B. Mode 3 Hot Shutdown C. Mode 4 Cold Shutdown D. Mode 5 Refueling Proposed Answer:
C Explanation A. See C B. See C C. Correct - Per Tech Spec Definitions Table 1.1-1 D. See C Technical Reference(s):
Tech Spec Definitions Table 1.1-1 Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 72 QUESTION 72 Rev 0 Examination Outline Cross-
Reference:
G2.3.11 IR 3.8 Ability to control radiation releases Proposed Question:
Due to a steam leak, the Main Steam Tunnel area temperatures have caused automatic isolations to occur as designed. Because of the location of the leak, no LOCA signals have been generated by RPV level or DW pressure. An ALERT has been declared due to offsite release rate.
Which one of the following will reduce the UNMONITORED release rate?
A. Shutdown the Turbine Building Ventilation System, if operating.
B. Shutdown the Fuel Building Ventilation System, if operating.
C. Start the Turbine Building Ventilation System, if not operating.
D. Start the Fuel Building Charcoal Ventilation System, if not operating.
Proposed Answer:
C Explanation A. This action would raise the unmonitored release rate B. The fuel building normal and charcoal filtration systems are both monitored; this would not affect unmonitored release C. Correct - IAW EOP-0003 D. See B Technical Reference(s):
EOP-0003 p. B-10-3 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-515, Obj 6 Question Source:
Bank #
RBS-NRC-797 Question History:
Last NRC Exam RBS 2003 NRC Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 73 QUESTION 73 Rev 0 Examination Outline Cross-
Reference:
G2.3.13 IR 3.4 Knowledge of radiological safety procedures pertaining to licensed operator duties, such as response to radiation monitor alarms, containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc Proposed Question:
For which of the following evolutions is the licensed operator in the control room procedurally required to notify Radiation Protection prior to performance?
A. Suppression Pool reject to Radwaste with Residual Heat Removal (RHR)
B. Placing Heater Drain pumps in the PUMP FORWARD mode C. Startup of Circulating Water Blowdown D. Reactor Core Isolation Cooling (RCIC) slow roll startup Proposed Answer:
D Explanation:
A. See D. (SOP-0031)
B. See D. (SOP-0010)
C. See D. (SOP-0006)
D. Although notifying RP prior to any of the 4 choices demonstrate good teamwork, only RCIC slow roll startup specifically requires notification per SOP-0035.
Technical Reference(s):
SOP-0035, RCIC, Rev 47 p. 16 of 76 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0209 Obj 10c Question Source:
Bank #
RBS Oct 2012 Audit Q#72 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 4 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 74 QUESTION 74 Rev 0 Examination Outline Cross-
Reference:
G2.4.12 IR 4.0 Knowledge of general operating crew responsibilities during emergency operations Proposed Question:
To which of the following Emergency Response Organization facilities is the Fire Brigade assigned to when not performing fire fighting functions?
A. Operations Support Center (OSC)
B. Technical Support Center (TSC)
C. Emergency Operating Facility (EOF)
D. Joint Information Center (JIC)
Proposed Answer:
A Explanation A. Correct - per EIP-2-016.
B. C. and D. See A Technical Reference(s):
EIP-2-016, Operations Support Center, Rev 29 p. 5 of 31 Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
Bank #
RBS Oct 2008 Audit Q#75 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments:
December 2014 River Bend Station NRC Initial License Examination Reactor Operator 75 QUESTION 75 Rev 0 Examination Outline Cross-
Reference:
G2.4.26 IR 3.1 Knowledge of facility protection requirements, including fire brigade and portable fire fighting equipment usage Proposed Question:
According to EN-OP-115, Conduct of Operations, a Fire Brigade of at least _(1)_
members shall be maintained on site at all times; the fire brigade members shall NOT include the _(2)_.
A. (1) Four ;
(2) Shift Technical Advisor (STA)
B. (1) Five ;
(2) Duty Manager C. (1) Five ;
(2) Shift Technical Advisor (STA)
D. (1) Four ;
(2) Duty Manager Proposed Answer:
C Explanation A. EN-OP-115 requires a minimum of 5 Fire Brigade Members B. Part 1 is correct; The Duty Manager is not designated as being precluded by procedure C. Correct - The fire brigade shall not include the OSM, CRS, STA, ATC, and 1 NEO D. EN-OP-115 requires a minimum of 5 Fire Brigade Members Technical Reference(s):
EN-OP-115, Conduct of Operations, Rev 15 p. 78 of 89 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-0206, Obj 7 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content: 55.41.b.10 Comments: Similar to Bank Question #RBS-OPS-3382
December 2014 River Bend Station NRC Examination Senior Reactor Operator 76 QUESTION 76 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295004 G2.2.44 IR 4.4 Ability to interpret control room indications to verify the status and operation of a system, and understand how operator actions and directives affect plant and system conditions (Partial or Complete Loss of DC)
Proposed Question:
During normal plant operation, several alarms are received on H13-P601 Insert 16, including:
DIV III 125VDC SYSTEM TROUBLE DIV III BATTERY CHARGER TROUBLE In addition to these alarms, the (2) 125VDC white power available lights on H13-P601 High Pressure Core Spray area are extinguished.
Which of the following procedures should the CRS enter to mitigate this condition?
A. SOP-0030, HIGH PRESSURE CORE SPRAY SYSTEM B. SOP-0049, 125 VDC SYSTEM C. AOP-0014, LOSS OF 125 VDC D. AOP-0042, LOSS OF INSTRUMENT BUS Proposed Answer:
C.
Explanation:
A. This procedure is for normal operation of the High Pressure Core Spray System. The stem indicates abnormal conditions.
B. This procedure is for normal operation of the 125 VDC System. The stem indicates abnormal conditions.
C. Correct-The conditions in the stem indicate that 125 VDC to the HPCS has been lost. The correct procedure for this condition is AOP-0014.
D. This procedure deals with the loss of various uninterruptible power supplies. These UPS systems are associated with Div 1, Div 2 and non-safety related components.
Technical Reference(s):
AOP-0014 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-OPS-0532 Obj 2 Question Source:
Bank#
April 2010 NRC Exam Question History:
Last NRC Exam April 2010 Q#77 Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.43.b.5 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 77 QUESTION 77 Rev 1 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295006 G2.4.34 IR 4.2 Knowledge of RO tasks performed outside the main control room during an emergency and the resultant operational effects. (SCRAM)
Proposed Question:
The plant has experienced an ATWS. The following conditions exist at the 680 panel:
The Mode Switch is in Shutdown ARI has been initiated Approximately 50% of the withdrawn rods fully inserted All eight white scram solenoid lights are extinguished The SDV Vent and Drain Valve position green lights are on and red lights are off Annunciator 680-05A-C08, SCRAM Pilot Valve Air Header Low Pressure NOT lit In accordance with EOP Enclosure 26, Control Rod Insertion Method Determination, which procedure should be directed to allow insertion of control rods?
A. EOP Enclosure 10, De-Energizing SCRAM Solenoids B. EOP Enclosure 11, Venting SCRAM Air Header C. EOP Enclosure 13, Opening Individual SCRAM Test Switches D. EOP Enclosure 17, Venting CRD Overpiston Volumes Proposed Answer:
B A. The stem conditions are indicative the failure of the scram air header to vent; scram solenoids are already de-energized.
B. Correct - this enclosure will vent the scram air header and allow the rods to be inserted.
C. and D. These two enclosures are used after the scram air header is depressurized.
Technical Reference(s): EOP-0001A RPV Control - ATWS; EOP-0005 Enclosure 26, Control Rod Insertion Method Determination Proposed references to be provided to applicants during examination:
None.
Learning Objective:
RLP-HLO-0513, Obj 5 Question Source:
Modified Bank#
RBS-OPS-06265 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.43.b.5 Comments: Original KA was G2.4.2, re-rolled (drew G2.4.34) ; The original KA was not conducive to writing an SRO level question.
December 2014 River Bend Station NRC Examination Senior Reactor Operator 78 QUESTION 78 Rev 1 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295021 AA2.04 IR 3.6 Ability to determine and/or interpret the following as they apply to LOSS OF SHUTDOWN COOLING : Reactor water temperature Proposed Question:
The plant is Shutdown in Mode 4 following 400 days of continuous operation.
A spurious Group 3 isolation occurs and the logic cannot be reset.
Reactor water temperature rises to 205F What is the time limit for notification to the NRC?
A. Immediate notification (within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />)
B. 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> notification C. 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> notification D. 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> notification Proposed Answer:
A Explanation A Correct - the conditions are indicative of a NOUE; a group 3 isolation would cause a loss of shutdown cooling; temperature rose enough for a mode change; notification is required immediately B 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> is a valid notification time but not for this condition.
C. 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> would be for an valid ESF actuation/isolation D. 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is a valid notification time but not for this condition.
Technical Reference(s):
EIP-2-001, Classification of Emergencies, Rev 24, Attach 10 EIP-2-002, Classification Actions, Rev 31, p. 7 of 20 Proposed references to be provided to applicants during examination: EIP-2-001, Attach 10 only Learning Objective:
(As available)
Question Source:
Bank# GGNS 2013 AUDIT Q# 79 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 4 10 CFR Part 55 Content: 55.43.b.5 Comments: Replaced question to make this SRO level
December 2014 River Bend Station NRC Examination Senior Reactor Operator 79 QUESTION 79 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295028 G2.4.21 IR 4.6 Knowledge of the parameters and logic used to assess the status of safety functions, such as reactivity control, core cooling and heat removal, reactor coolant system integrity, containment conditions, radioactivity release control, etc. (High Drywell Temperature)
Proposed Question:
A transient occurred that caused the Control Room Team to enter the Alternate Level Control Leg of EOP-1. While executing the ALC steps, a large break LOCA, ALL RPV level instruments indicated off-scale low.
Five seconds later, the Fuel Zone Level instruments returned on scale. The following conditions now exist:
Containment temperature 91°F (at EL 119 ft)
Drywell temperature 285°F (at EL 145 ft)
RPV Pressure 10 psig Fuel Zone Level indication -290 inches, rising and falling rapidly With these conditions, Fuel Zone Level indication ____ be used to determine RPV level ;
the CRS should direct ____.
A. CANNOT ; Emergency Depressurizing per EOP-1 B. CANNOT ; exiting EOP-1 and entering EOP-4 C. CAN ; restoring and maintaining RPV level above -162 inches per EOP-1 D. CAN ; exiting the ALC leg and entering the Steam cooling leg of EOP-1 Proposed Answer:
B Explanation A. Incorrect per override RC-2 of EOP-1 B Correct per override RC-2 EOP-4 must be entered C, D - Incorrect, FZ level indication is unreliable due to boiling in the instrument line run Technical Reference(s):
EOP-1, RPV Control, Rev 26 Proposed references to be provided to applicants during examination: Caution 1 of EOP-1 Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.43.b._
Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 80 QUESTION 80 Rev 1 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
295031 EA2.04 IR 4.8 Ability to determine and/or interpret the following as they apply to REACTOR LOW WATER LEVEL: Adequate core cooling Proposed Question:
The following conditions exist:
Reactor Pressure is 943 psig RHR pumps A and C are lined up for injection HPCS injection has commenced Reactor water level is -190 and slowly lowering Which of the following is correct concerning cooling of the core, and Which procedural action should the SRO direct next?
A. Adequate core cooling exists and Steam Cooling is required.
B. Adequate core cooling exists and Spray Cooling is required.
C. Adequate core cooling does not exist and Emergency Depressurization is required.
D. Adequate core cooling does not exist and Containment Flooding is required.
Proposed Answer: C Explanation A. -200 is the water level for steam cooling without injection B. -211 is the water level for spray cooling, at 943 psig HPCS will not develop 5000 gpm C. Correct - adequate core cooling does not exist, ED is necessary to allow low pressure ECCS to inject D. Containment flooding would be required if adequate core cooling could not be restored and maintained.
Technical Reference(s):
EOP Bases Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.43.b.5 Comments: Revised question to include procedural choice to make this SRO level
December 2014 River Bend Station NRC Examination Senior Reactor Operator 81 QUESTION 81 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
600000 AA2.16 IR 3.5 Ability to determine and interpret the following as they apply to PLANT FIRE ON SITE: Vital equipment and control systems to be maintained and operated during a fire Proposed Question:
The control room has received a report of a fire on the east side crescent area of the auxiliary building. The reactor has been shut down and the current conditions are:
Reactor Recirc Pumps both in slow speed Reactor pressure 125 psig and lowering RPV level 36 and steady What direction should the CRS give concerning Shutdown Cooling (SDC) operation?
A. Place RHR-B in normal SDC per SOP-0031, RHR System B. Place RHR-A in normal SDC per SOP-0031, RHR System C. Place RHR-C in alternate SDC per AOP-0020, Alternate Decay Heat Removal D. Place RHR-B in alternate SDC per AOP-0020, Alternate Decay Heat Removal Proposed Answer:
B Explanation A. C. and D. Per AOP-0052, Attachment 1 Div 2 equipment is not available B. Correct-Per AOP-0052, Attachment 1 this equipment is available Technical Reference(s):
AOP-0052, Fire Outside the MCR, Rev 25 Attachment 1 Proposed references to be provided to applicants during examination: of AOP-52 Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.43.b.5 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 82 QUESTION 82 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 1 K/A #
700000 G2.2.37 IR 4.6 Ability to determine operability and/or availability of safety related equipment (Generator Voltage and Electric Grid Disturbances)
Proposed Question:
The plant is operating at rated power.
A grid disturbance occurs that causes:
Alarm P808-86A-H09, PFD STA XFMR 1RTX-XSR1C VOLTAGE LOW ENS-ACB06 ENS-SWG1A PFD Supply BKR trips on under voltage Div I DG starts and ties to the bus An attempt to re-close ENS-ACB06 was unsuccessful A CR has been initiated concerning the status of the ENS-ACB06 ENS-SWG1A PFD Supply BKR.
What Operability Code should be assigned to the initial screening of this CR in PCRS?
AND Which T.S., if any, should be entered?
A. INOPERABLE and T.S. 3.8.1. condition A B. OPERABLE and no T.S. entry C. INOPERABLE-OP EVAL and T.S. 3.8.1. condition A D. OPERABLE-COMP MEAS and no T.S. entry Proposed Answer:
A Technical Reference(s):
AOP-0064, Degraded Grid, Rev 6 ENS-DC-199, Offsite Power Supply Design Requirements, Attach 9.3 Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 10 CFR Part 55 Content: 55.43.b.2 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 83 QUESTION 83 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
295015 AA2.02 IR 4.2 Ability to determine and/or interpret the following as they apply to INCOMPLETE SCRAM : Control rod position Proposed Question:
Following a high drywell differential pressure scram signal, the following conditions exist:
142 control rods indicate Full-In 3 control rods are not full in and are at various positions Reactor power indicates 0%
SRMs are inserted and count rates are lowering (1) What is the status of the reactor and (2) what procedure does the CRS direct?
A. The reactor will remain shutdown without boron; Enter EOP-1, RPV Control B. It can NOT be determined that the reactor will remain shutdown under all conditions without boron; Enter EOP-1, RPV Control and transition to EOP-1A, RPV Control, ATWS.
C. It can NOT be determined that the reactor will remain shutdown under all conditions without boron; Enter EOP-1, RPV Control, EOP-1A is NOT applicable with reactor power less than 5%.
D. The reactor will remain shutdown without boron; Enter EOP-1, RPV Control and transition to EOP-1A, RPV Control, ATWS Proposed Answer:
B Explanation A. and D. With more than one rod out, it can not be determined that the reactor will remain shutdown. IAW EOP Bases, For the current fuel design and core load, the MSBWP is all control rods fully inserted.
B. Correct - With more than one rod out, it can not be determined that the reactor will remain shutdown under all conditions without boron; A high drywell differential pressure scram signal is an EOP-0001 entry condition, transition to EOP-1A is required due to override step RC-2 in EOP-1.
C. First part correct, however, EOP-1 override RC-2 directs exiting EOP-1 and entering EOP-1A Technical Reference(s):
EOP Bases p. B-6-5 Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
Modified Bank # 2008 Audit Q#25 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.43.b.5 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 84 QUESTION 84 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
295029 G2.2.25 IR 4.2 Knowledge of the bases in Technical Specifications for limiting conditions for operations and safety limits (High Suppression Pool Wtr Lvl)
Proposed Question:
Technical Specifications (TS) require suppression pool water level to be < 20 ft 0 inches.
What is the TS basis for this upper limit?
A. Above 20 ft 0 inches, excessive pressure could build up in the drywell before the drywell horizontal vents are cleared during a DBA LOCA.
B. Water levels above 20 ft 0 inches would cause low pressure ECCS systems to operate outside of their design NPSH values.
C. Water levels above 20 ft 0 inches would overflow the drywell weir wall and cause inaccurate drywell leakage indications due to excessive pedestal sump discharge flow.
D. Above 20 ft 0 inches, SRV tail pipe pressure could build up too high during SRV operation and damage the tail pipes.
Proposed Answer: D Explanation A. A higher DW pressure buildup would occur as suppression pool level rises but this is within design analysis and excessive pressure buildup would not occur. This condition is not mentioned in the bases.
B. Levels above 20 ft would raise NPSH of the low pressure ECCS pumps but would not cause them to operate outside of design parameters.
C. The weir wall would overflow at 21 ft 3 inches and cause the pedestal sump to cycle but this is not mentioned as a basis for the upper limit D. Correct - TS 3.6.2.2 Bases Statement; If the suppression pool water level is too high, it could result in excessive clearing loads from S/RV discharges.
Technical Reference(s):
Tech Spec 3.6.2.2 and Bases Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.43.b.2 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 85 QUESTION 85 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 1 Group # 2 K/A #
500000 EA2.03 IR 3.8 Ability to determine and / or interpret the following as they apply to HIGH PRIMARY CONTAINMENT HYDROGEN CONCENTRATIONS: Combustible limits for drywell Proposed Question:
The plant has experienced a LOCA. The following conditions exist:
RPV pressure is 250 psig RPV level is +10 inches and slowly rising Containment pressure is 1.5 psig Drywell temperature is 200°F Drywell hydrogen concentration is 2 percent Containment hydrogen concentration is 2 percent Based on this, the SRO should ________.
A. Enter EOP-2 at Hydrogen Control and Verify start of Div. I and Div. II H2 monitoring systems B. Continue EOP-1 at Pressure Control and initiate shutdown cooling C. Enter EOP-2 at Hydrogen Control and operate all hydrogen igniters D. Exit all EOPs and enter the SAPs Proposed Answer:
C Explanation With hydrogen concentration above 1.5%, all igniters should be operated A - Hydrogen mixing not authorized in EOP-2 B - Shutdown cooling interlock not clear D - Drywell / Containment H2 concentration is not high enough Technical Reference(s):
EOP Bases p. B-8-26 & 27 Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.43.b.2 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 86 QUESTION 86 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
205000 A2.03 IR 3.2 Ability to (a) predict the impacts of the following on the SHUTDOWN COOLING SYSTEM (RHR SHUTDOWN COOLING MODE) ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: A.C. failure Proposed Question:
The plant is shutdown, in Mode 4 with RHR A in SDC mode and no Recirc Pumps running. A leak in the drywell causes RPV Level to lower. An operator begins to line up RHR A for Injection mode.
When E12-F006A, RHR Pump A SDC Suction Valve begins to close, electrical power is lost to the valve. The operator closes E12-F008 and -F009, RHR Shutdown Cooling Outboard and Inboard Isolation valves.
The CRS will direct ___ ; and RHR A Shutdown Cooling is ___.
A. Manually closing E12-F006A ;
Operable B. Aligning RHR Injection through E12-F0053A, RHR A SDC Injection Valve ;
Operable C. Manually closing E12-F006A ;
Inoperable D. Aligning RHR Injection through E12-F0053A, RHR A SDC Injection Valve ;
Inoperable Proposed Answer:
A Explanation A. Correct - The RHR Suppression Pool Injection Suction Valve (F004) cannot be opened with the F006 valve not full closed, but the F006 valve can be manually closed thereby allowing the F004 valve to be opened; Without opening closing the F006 and opening the F004, there is no suction path available to allow for injecting in any path.
RHR is operable because the LCO statement reads: An OPERABLE RHR shutdown cooling subsystem consists of one OPERABLE RHR pump, two heat exchangers in series, and the associated piping and valves. Each shutdown cooling subsystem is considered OPERABLE if it can be manually aligned (remote or local) in the shutdown cooling mode for removal of decay heat.
Technical Reference(s):
AOP-0051, Loss of Decay Heat Removal, Rev 312 Tech Spec Bases 3.4.10 p. 3.4-48 and 49 Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.43.b.2 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 87 QUESTION 87 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
212000 G2.2.12 IR 4.1 Knowledge of surveillance procedures (RPS)
Proposed Question:
The plant is operating at 90% power. STP-508-0201, Manual Scram Channel Functional Test and LSFT is being performed. The last division is being restored.
When the operator attempted to reset the half-scram, status light H13-P680-11E1, RPS DIV 4 SCRAM SOV VALVES OPEN - CR 4B white light is NOT on.
All other SOV status lights are lit.
A loss of RPS Bus B occurs; what is the expected plant response and what AOP(s) should be entered?
A. All of the control rods will scram ;
AOP-0001, Reactor Scram only B. Approximately 1/4 of the control rods will scram ;
AOP-0001, Reactor Scram only C. Approximately 1/4 of the control rods will scram ;
AOP-0001, Reactor Scram, and AOP-0010, Loss of RPS Bus D. None of the control rods will scram ;
AOP-0010, Loss of RPS Bus only Proposed Answer:
D Explanation A. See D B. See D C. See D D. Correct - The loss of RPS B will only cause a half-scram signal; The Div 4 SOV is powered by RPS-B, so a loss of RPS B would have de-energized the CR4B which is already de-energized; IF the transient had been a loss of RPS A, it would have caused approximately 1/4 of the rods to scram due to de-energizing the second SOV in Div 4 and actions would need to be taken to insert a manual scram and enter AOP-1.
AOP-0010 must be entered in order to restore power to the bus and reset isolation signals.
Technical Reference(s):
R-STM-508, RPS, Rev 5 p. 23 of 59; STP-508-0201, Rev 14 pp 19-20 of 26 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0508, Obj 8 Question Source:
Modified Bank # RBS-NRC-937 Question History:
Last NRC Exam Sept 2004 NRC Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.43.b.5 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 88 QUESTION 88 Rev 1 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
215005 A2.02 IR 3.7 Ability to (a) predict the impacts of the following on the AVERAGE POWER RANGE MONITOR/LOCAL POWER RANGE MONITOR SYSTEM ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Upscale or downscale trips Proposed Question:
GOP-0001 Plant Startup requires verification that all APRMs are >5% prior to taking the mode switch to RUN. This step was signed and then a shift turnover occurred.
The mode switch is taken to run. APRMs B & C are both reading <5%.
All other APRMs are operable and are reading >5%.
The result of this condition is a ___; the CRS will direct ___.
A. reactor scram ; actions according to EOP-0001, RPV Control.
B. Control Rod Withdrawal Block ; bypassing APRMs B & C to clear the rod block per EN-OP-115, Conduct of Operations C. Control Rod Withdrawal Block ; be in Mode 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> in accordance with Tech Specs.
D. half scram ; transfer the Mode Switch back to START & HOT STBY per GOP-0002, Power Decrease/Plant Shutdown.
Proposed Answer:
B Explanation A. There will be a rod withdraw block not a scram.
B. Correct - With mode switch in run and APRMs <5%, a rod withdraw block will occur; not a scram. With all other APRMs operable, B & C can be bypassed to clear the rod block. Tech Specs allow bypassing one channel from each trip system. Rods can be withdrawn to bring B & C above 5%.
C. First Part is correct, but this Tech Specs required action is for when one or more required channels are inoperable; Tech Specs only requires 3 channels per trip system (which in the given condition, is met)
D. A half scram is not present for two APRMs < 5%.
Technical Reference(s):
SOP-0074, Neutron Monitoring, Rev 306 p.20 of 74 R-STM-0503, RPS, Rev 7, pp. 63,68,106 of 112 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0503, Obj 26,28 Question Source:
Bank #
2008 RBS AUDIT Q#89 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.43.b.5 Comments: Question revised to force procedure selection to make it SRO level
December 2014 River Bend Station NRC Examination Senior Reactor Operator 89 QUESTION 89 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
239002 A2.06 IR 4.3 Ability to (a) predict the impacts of the following on the RELIEF/SAFETY VALVES ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Reactor high pressure Proposed Question:
While operating at 100% power, a loss of condenser vacuum occurs..
After a reactor scram, the following plant conditions exist:
Reactor pressure spiked to 1140 psig Main Turbine has tripped Condenser vacuum 0 (1) What is the current pressure control band for SRV 51D?
(2) What direction does the CRS give to control Reactor pressure?
A. (1) 1063 psig to 956 psig (2) Stabilize pressure with SRVs, then establish a band of 500 to 1090 pounds in accordance with OSP-0053, Emergency and Transient Response.
B. (1) 1063 psig to 956 psig (2) Install Enclosure 9, Defeating MSIV Isolation Interlocks, and open MSIVs C. (1) 1103 psig to 966 psig (2) Stabilize pressure with SRVs, then establish a band of 500 to 1090 pounds in accordance with OSP-0053, Emergency and Transient Response.
D. (1) 1103 psig to 966 psig (2) Install Enclosure 9, Defeating MSIV Isolation Interlocks, and open MSIVs Proposed Answer:
A Explanation A. Correct - set points for 51D ; SRVs are the only available system due to low vacuum B. First part is correct; Encl 9 is only allowed for alternate pressure control in this condition C.. and D. First part is incorrect - these are the LLS set points for SRV 51C Technical Reference(s):
R-STM-0109, Main Steam, Rev 13 pp. 36,37,60 of 95 EOP-1, RPV Control Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0109, Obj 22 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 3 10 CFR Part 55 Content: 55.43.b.5 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 90 QUESTION 90 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
262001 G2.2.25 IR 4.2 Knowledge of the bases in Technical Specifications for limiting conditions for operations and safety limits (AC Electrical Distribution)
Proposed Question:
Due to a loss of EJS*LDC2A, you have entered TS 3.8.9 condition A (One or more Division I or II AC electrical power distribution subsystems inoperable). The required action is to Restore Division I and II AC electrical power distribution subsystems to OPERABLE status.
The 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> completion time for this LCO action is based on:
A. the unit is more vulnerable to a complete loss of AC power B. the plant is significantly more vulnerable to a complete loss of all uninterruptible power.
C. the plant is significantly more vulnerable to a complete loss of DC power.
D. the plant is significantly more vulnerable to a complete loss of D/G power.
Proposed Answer:
A Explanation A. Correct-copied from the bases for condition A B. This applies to condition B C. This applies to condition C D. This applies to TS 3.8.1 condition A Technical Reference(s):
Tech Spec Bases 3.8.9 p. B 3.8-81 Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 4 Comprehension or Analysis 10 CFR Part 55 Content: 55.43.b.2 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 91 QUESTION 91 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
201005 G2.1.23 IR 4.4 Ability to perform specific system and integrated plant procedures during all modes of plant operation (RCIS)
Proposed Question:
GOP-001, Plant Startup is in progress currently in Section C (Approach to Critical:
Instructions). Pulling control rods began two hours ago. The dedicated reactor operator has just informed you that a single control rod was pulled out of sequence (4 notches).
What will you direct the reactor operator to do?
A. Manually scram the reactor and enter AOP-0001, Reactor Scram B. Perform a MON calculation to determine margin to Preconditioning Envelope per GOP-0001, Plant Startup.
C. Select and continuously insert the control rod to position 00 per AOP-0061 Mispositioned Control Rod.
D. Suspend all rod motion and enter AOP-0061, Mispositioned Control Rod.
Proposed Answer:
D Explanation A. This action is directed in AOP-61 when more than one rod has scrammed or been fully inserted.
B. This would be a required action if a control rod is found in an unintended position or a single rod scram were to have occurred.
C. This is the required action for a drifting rod.
D. Correct - GOP-1 Caution for step 11 directs IF an out of sequence rod should be withdrawn, THEN suspend rod motion, notify the OSM, and reference AOP-0061. AOP-61, Step 5.2 directs returning the rod to its required position and notify Reactor engineering.
Technical Reference(s):
GOP-0001, Plant Startup, Rev 82 p. 34 of 103 AOP-0061, Mispositioned Control Rod, Rev 7 p. 5 of 8 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-0711, Obj 4 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.43.b.5 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 92 QUESTION 92 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
204000 A2.14 IR 3.2 Ability to (a) predict the impacts of the following on the REACTOR WATER CLEANUP SYSTEM ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:
System High Temperature Proposed Question:
A partial loss of Reactor Plant Component Cooling Water (CCP) has resulted in reduced cooling to the Reactor Water Cleanup System (RWCU).
How will the RWCU system respond, and what actions are required to mitigate that response?
A. G33-F001, RWCU Pumps Inbd Suction Valve will close when NRHX outlet temperature 140°F ;
Transfer resin to the holding tank until CCP restored per SOP-0090.
B. G33-F001, RWCU Pumps Inbd Suction Valve will close when NRHX outlet temperature 140°F ;
Secure RWCU per SOP-0090.
C. G33-F004, RWCU Pumps Outbd Suction Valve will close when NRHX outlet temperature 140°F ;
Transfer resin to the holding tank until CCP restored per SOP-0090.
D. G33-F004, RWCU Pumps Outbd Suction Valve will close when NRHX outlet temperature 140°F ;
Secure RWCU per SOP-0090.
Proposed Answer:
D Explanation A. See D B. See D C. Part 1 is correct; See D for Part 2 D. Correct - G33-F001 and F004 are interlocked to close on SLC injection, but only F004 is interlocked to close on Filter/Demin inlet temperature; The ARP requires either reducing flow through demins (Alarm at 130°F) or securing the system Technical Reference(s):
ARP-680-01-B01 & -C01; R-STM-0601, RWCU, Rev 8 pp. 15-16, 25-26 of 51 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0601, Obj 7 Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.43.b.5 Comments: Original KA was A2.02, re-rolled (drew 2.14). RBS does not have Low Press RWCU.
December 2014 River Bend Station NRC Examination Senior Reactor Operator 93 QUESTION 93 Rev 0 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 2 K/A #
290001 A2.04 IR 3.7 Ability to (a) predict the impacts of the following on the SECONDARY CONTAINMENT; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:
High airborne radiation Proposed Question:
A RWCU leak has occurred in the RWCU pump room and control room attempts to isolate the leak have failed. Work management is establishing a team to enter the Aux Building to attempt to drive the isolation valves closed from the motor control centers.
Area temperature monitors show the following readings:
RWCU PUMP ROOM 210F RHR EQUIPMENT AREA A 90F RCIC EQUIPMENT AREA 150F RHR EQUIPMENT AREA B 85F The Digital Radiation Monitoring System (DRMS) shows the following indications:
RMS-RE110, AUX BLDG VENT - Alarm (RED)
RMS-RE213, RHR EQUIPMENT ROOM A - Normal (Green)
RMS-RE214, RHR EQUIPMENT ROOM B - Normal (Green)
RMS-RE215, RHR EQUIPMENT ROOM C - ALERT (Yellow)
RMS-RE217, HPCS PENETRATION AREA - Normal (Green)
RMS-RE218, LPCS PENETRATION AREA - Normal (Green)
RMS-RE219 RCIC EQUIPMENT ROOM - ALERT (Yellow)
What impact could these radiation levels have and what procedural actions should be directed A. High Radiation levels will have no impact they only provide indication that water from a primary system may be discharging into secondary containment; the RPV should be emergency depressurized.
B. High radiation levels may preclude personnel access and lead to equipment failure; the Aux building should be isolated per OSP-0053 Attachment 21 hard card.
C. High Radiation levels may preclude personnel access and lead to equipment failure; the RPV should be emergency depressurized.
D. High Radiation levels will have no impact they only provide indication that water from a primary system may be discharging into secondary containment; the Aux building should be isolated per OSP-0053 Attachment 21 hard card.
Proposed Answer:
B
December 2014 River Bend Station NRC Examination Senior Reactor Operator 94 Explanation A. While high radiation levels are indication that there may be a primary system discharging into secondary containment there is still the potential for radiation levels to preclude access and cause equipment failure. Criteria for ED have not been met.
B. Correct - High radiation levels have the potential to preclude access and cause equipment failure, with RMS-RE110 in alarm the auxiliary building should be isolated and exhaust processed through the standby gas system to minimize release to the public.
C. Criteria for ED have not been met.
D. While high radiation levels are indication that there may be a primary system discharging into secondary containment there is still the potential for radiation levels to preclude access and cause equipment failure Technical Reference(s):
EOP BASES Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 4 10 CFR Part 55 Content: 55.43.b.5 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 95 QUESTION 94 Rev 0 Examination Outline Cross-
Reference:
G2.1.20 IR 4.6 Ability to interpret and execute procedure steps Proposed Question:
Refueling is in progress. Reactor Recirculation and Reactor Water Cleanup System are secured for system maintenance.
How is TR 3.4.13, Chemistry satisfied for reactor coolant conductivity during this portion of a refueling outage?
A. The conductivity of the reactor coolant is recorded continuously.
B. An in-line conductivity measurement is obtained every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
C. An in-line conductivity measurement is obtained every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
D. Not required to be met in this mode.
Proposed Answer:
C.
Explanation:
A. With both Reactor Recirculation and RWCU secured, continuous monitoring is not available.
B. This would be required in Modes 1, 2, & 3.
C. Correct - Continuous monitoring is not available so an inline conductivity measurement must be obtained every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
D. Required at all times.
Technical Reference(s):
TR 3.4.13 Proposed references to be provided to applicants during examination:
TR 3.4.13 Learning Objective:
RLP-STM-0601 Obj. 9 Question Source:
Bank # Dec 2010 NRC Q#95 Question History:
Last NRC Exam Dec 2010 NRC Cognitive Level:
Memory or Fundamental Knowledge Comprehension or Analysis 2 10 CFR Part 55 Content: 55.43.b.2 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 96 QUESTION 95 Rev 0 Examination Outline Cross-
Reference:
G2.1.36 IR 4.1 Knowledge of procedures and limitations involved in core alterations Proposed Question:
During a refuel outage, the Outage Control Center notifies the main control room that core alterations are scheduled to commence next shift.
Select the procedure below which the CRS utilizes to ensure that all requirements for core alterations have been met.
A. STP-000-0005, DAILY REFUELING LOGS B. GMP-0102, REACTOR VESSEL DISASSEMBLY C. FHP-0001, CONTROL OF FUEL HANDLING AND REFUELING OPERATIONS D. FHP-0003, REFUEL PLATFORM OPERATION Proposed Answer:
C.
Explanation:
A. See C.
B. See C.
C. Correct - FHP-0001 Attachment 2 contains a list of Applicalbe Mode 5 Tech Specs which includes (section 2) a list of requirements to commence core alterations.
D. See C.
Technical Reference(s): FHP-0001, Control of Fuel Handling & Refueling Ops, Rev 35 pp. 4, 35 of 40 Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-STM-0055 Obj 6 & 9 Question Source:
Bank #
Nov 2012 NRC Q#95 Question History:
Last NRC Exam Nov 2012 NRC Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.43.b.7 Comments: Appeared on one of last 2 NRC exams (2 of 2):
December 2014 River Bend Station NRC Examination Senior Reactor Operator 97 QUESTION 96 Rev 0 Examination Outline Cross-
Reference:
G2.2.11 IR 3.3 Knowledge of the process for controlling temporary design changes Proposed Question:
An event has occurred which presents an imminent threat to the safety of the plant.
In order to mitigate the event a temporary modification must be installed as directed by the Shift Manager. Whose concurrence is required to implement the emergency temporary modification?
A. Another SRO B. The RBS Vice President (VP)
C. The General Manager Plant Operations (GMPO)
D. The Engineering Director or his designee Proposed Answer:
D Explanation A. See D B. See D C. See D D. Correct - Per EN-DC-136, the concurrence of the Engineering Director, or designee is required Technical Reference(s):
EN-DC-136, Temporary Modifications, Rev 10 Section 5.3 Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.43.b.3 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 98 QUESTION 97 Rev 0 Examination Outline Cross-
Reference:
G2.2.38 IR 4.5 Knowledge of conditions and limitations in the facility license Proposed Question:
Which of the Limiting Conditions for Operation (LCOs) listed below provide guidance concerning when changes in mode or other specified conditions are allowed when an LCO is not met?
A. LCO 3.0.2 B. LCO 3.0.3 C. LCO 3.0.4 D. LCO 3.0.6 Proposed Answer:
C.
Explanation:
A. 3.0.2 establishes that upon discovery to meet an LCO, the associated ACTIONS must be met.
B. 3.0.3. establishes the actions that must be met when an LCO is not met and the actions and completions times are not met and no other actions apply.
C. Correct D. 3.0.6 establishes exception to 3.0.2 for support systems that have an LCO in the Tech Specs.
Technical Reference(s):
LCO 3.0.4 Bases Proposed references to be provided to applicants during examination:
None Learning Objective:
RLP-HLO-416 Obj 15.
Question Source:
Bank #
Nov 2010 Audit Q#96 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 4 Comprehension or Analysis 10 CFR Part 55 Content: 55.43.b.1 Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 99 QUESTION 98 Rev 1 Examination Outline Cross-
Reference:
G2.3.14 IR 3.8 Knowledge of radiation or contamination hazards that may arise during normal, abnormal, or emergency conditions or activities Proposed Question:
Which of the following statements explains the significance of the Maximum Safe Area Radiation Level being reached in the areas identified in EOP-0003, Secondary Containment and Radioactive Release Control?
A. This is the value that requires entry into EOP-0003.
B. This is the value that requires isolating all systems discharging into the area except systems (1) required for damage control, and (2) required to be operated by EOPs.
C. This value in any one area requires the plant to be shutdown per GOP-0002 Plant Shutdown IAW EOP-0003.
D. This value along with a primary system discharging into secondary containment requires entry into EOP-0001 RPV Control IAW EOP-0003.
Proposed Answer:
D Explanation A. The maximum normal operating value is the entry condition for EOP-0003.
B. The max normal operating value is used as the stop sign before this action in EOP-3.
C. EOP-0003 requires two areas to be at the Maximum Safe value prior to shutting down per GOP-0002 Plant Shutdown D. Correct -
Technical Reference(s): EOP Bases Proposed references to be provided to applicants during examination:
None Learning Objective:
(As available)
Question Source:
New Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.43.b.5 Comments: Distractor B replaced due to plausibility
December 2014 River Bend Station NRC Examination Senior Reactor Operator 100 QUESTION 99 Rev 0 Examination Outline Cross-
Reference:
G2.4.16 IR 4.4 Knowledge of EOP implementation hierarchy and coordination with other support procedures or guidelines such as, operating procedures, abnormal operating procedures, and severe accident management guidelines Proposed Question:
The plant is at 100% power when a manual reactor scram is inserted due to a steam leak on Moisture Separator Reheater B.
The Control Room Supervisor should:
A. Enter AOP-0001, REACTOR SCRAM, AOP-0002, TURBINE TRIP and EOP-0001, RPV CONTROL concurrently. EOP-0001 may be exited when it is determined that an emergency no longer exists.
B. Enter AOP-0001, REACTOR SCRAM and AOP-0002, TURBINE TRIP. After AOP immediate actions and required subsequent actions are complete, enter EOP-0001, RPV CONTROL. EOP-0001 may be exited when it is determined that an emergency no longer exists.
C. Enter EOP-0001, RPV CONTROL and exit when it is determined that an emergency no longer exists. Then enter AOP-0001, REACTOR SCRAM and AOP-0002, TURBINE GENERATOR TRIP.
D. Enter AOP-0001, REACTOR SCRAM, AOP-0002 TURBINE GENERATOR TRIP, and EOP-0001, RPV CONTROL concurrently. EOP-0001 may only be exited when directed by exit steps in the procedure.
Proposed Answer:
A.
Explanation:
A. Correct - The AOPs and EOP are entered concurrently. The EOP is exited when the emergency no longer exits.
B. The listed procedures are executed concurrently.
C. The listed procedures are executed concurrently.
D. First part is correct, but the EOP may be exited when the emergency no longer exists. Exit steps normally only are provided for escalating conditions.
Technical Reference(s):
OSP-0009, Section 10.2 Proposed references to be provided to applicants during examination: None Learning Objective: R-LPOPS-HLO218 Obj 4; R-LP-OPS-HLO520 Obj 2; R-LPOPS-HLO512 Obj 4 Question Source:
Bank #
Oct 2012 Audit #99 Question History:
Last NRC Exam NA Cognitive Level:
Memory or Fundamental Knowledge 2 Comprehension or Analysis 10 CFR Part 55 Content:
55.43.b.5 Comments:
Comments:
December 2014 River Bend Station NRC Examination Senior Reactor Operator 101 QUESTION 100 Rev 0 Examination Outline Cross-
Reference:
G2.4.44 IR 4.4 Knowledge of emergency plan protective action recommendations Proposed Question:
Following the declaration of a General Emergency, Protective Action Recommendations (PARs) are issued by ______________.
A. Parish Officials.
B. State Officials.
C. Federal Emergency Management Agency.
D. Emergency Director.
Proposed Answer:
D.
Explanation:
A. See D.
B. See D.
C. See D.
D. The Emergency Director issues PARs. Offsite agencies determine whether or not to act upon the recommendation.
Technical Reference(s):
EIP-2-007, Protective Action Recommendations, Rev 25 p. 3 of 9 Proposed references to be provided to applicants during examination:
None Learning Objective:
None identified.
Question Source:
Bank #
RBS-Audit 2010 #99 Question History:
Last NRC Exam RBS NRC 2007 Cognitive Level:
Memory or Fundamental Knowledge 3 Comprehension or Analysis 10 CFR Part 55 Content: 55.43.b.5 Comments:
RBS December 2014 NRC Initial Written Exam Modified Question - Parent Questions Q#
Parent Question 7
RBS December 2008 NRC Exam #8 16 RBS-OPS-5554 22 RBS-NRC-01108 23 RBS-NRC-444 37 Nov 2010 Audit Q#36 38 RBS-NRC-53 44 RBS-NRC-459 51 RBS-OPS-3255 56 RBS-NRC-168 60 RBS-OPS-06288 62 RBS-LOR-1252 64 RBS-OPS-2307 77 RBS-OPS-06265 83 2008 Audit Q#25 87 RBS-NRC-937
Exam Question # 7 Modified from Parent Q# RBS December 2008 NRC Exam #8 QUESTION 8 Rev 0 Examination Outline Cross-
Reference:
1 Group #
1 K/A #
295019 AA1.03 Importance Rating 3.0 Proposed Question:
Due to severe weather in the area around River Bend Station, a loss of offsite power has occurred.
All three diesel generators have started and are supplying safety related loads.
What is the status of the Plant Air Systems?
- a. The Service Air compressors will be de-energized. Instrument Air compressors will be supplied by a safety related power source.
- b. The Instrument Air compressors will be de-energized. SAS-AOV134 cross-connect valve will open to maintain IAS header pressure with the SAS compressors.
- c. Instrument Air and Service Air compressors will both be de-energized. The diesel air compressor will automatically start to supply plant air needs.
- d. Instrument Air and Service Air compressors will both be de-energized. The diesel air compressor must be manually started to supply plant air needs.
Proposed Answer:
D.
Exam Question # 16 Modified from Parent Q# RBS-OPS-5554 As part of a routine surveillance, valve timing is being performed on the Low Pressure Core Spray (LPCS) system valves. Currently all valves are in their normal standby position except for E21-MOVF001, Suppression Pool Suction Valve, which is closed. A valid high drywell pressure, Low Pressure Core Spray (LPCS) initiation signal is received.
Assuming no operator action, which of the following statements identifies the expected response of LPCS?
A. LPCS Pump will start and run with pump suction valve E21-MOVF001 closed.
B. LPCS Pump will start and then immediately trip because it has no suction path.
C. LPCS Pump will not receive a start signal because the suction path permissive is not met.
D. E21-MOVF001 receives an automatic open signal and the LPCS Pump starts when the valve is full open.
Answer: A
Exam Question # 22 Modified from Parent Q# RBS-NRC-01108 River Bend was operating at full power with RCIC tagged out. A trip of all Reactor Feedwater Pumps caused RPV level to drop and a Reactor scram to occur on low RPV water level. HPCS recovered RPV level and E22-F004, HPCS INJECT ISOL VALVE was closed when RPV water level reached +35 inches. Conditions are currently:
Vessel is isolated from the condenser Reactor pressure 700 psig (rising at 10 psig per minute)
Time after scram 5 minutes CRD pumps both tripped Drywell pressure 0.3 psid If no additional operator actions are taken other than the ones listed, what is the expected RPV water level response over the next 10 minutes and why?
A. rise due to swell from decay heat.
B. rise due to Feed Reg. Valve leakage exceeding heat requiements.
C. lower due to cooldown.
D. lower due to steam loads reducing RPV water inventory.
Answer: A
Exam Question # 23 Modified from Parent Q# RBS-NRC-444 Given the following plant conditions:
- Reactor Power 0% (all rods in)
- Reactor Level +33 inches
- Reactor Pressure 890 psig
- Drywell Pressure 1.8 psid
- Drywell Temperature 138°F
- Containment Temperature 88°F
- Containment Pressure 0.35 psig
- Annulus Differential Pressure -4.5 in.WC Based on the above conditions, which one of the following describes the Emergency Operating Procedures that should be entered?
A. EOP-1 ONLY B. EOP-1 and 2 C. EOP-2 ONLY D. EOP-2 and 3 Answer: B
Exam Question # 37 Modified from Parent Q# Nov 2010 Audit Q# 36 Examination Outline Cross-
Reference:
Level RO SRO Tier # 2 Group # 1 K/A #
215004 IR 2.6 Knowledge of the electrical power supplies to SRM channels/detectors.
Proposed Question:
The power supply to SRM A detector is ______________.
A. VBS-PNL01A B. VBS-PNL01B C. RPS A D. RPS B Proposed Answer:
C.
Exam Question # 38 Modified from Parent Q# RBS-NRC-53 During a reactor startup the ATC has been withdrawing SRM detectors per GOP-0001.
All SRMs except A indicate full out. SRM A has an upscale high and an upscale High-high trip indicated and is reading off-scale high. The P680 indications show the detector is "driving out."
The ATC should...
A. Immediately insert control rods to return SRM A readings on-scale.
B. Insert a Div I half scram and continue with the plant startup.
C. Check the SRM A drive power fuses, if the problem is not corrected, obtain reactor engineering assistance..
D. Since the other drive OUT lights are on, SRM A drive has power therefore contact I &
C for assistance.
Answer: C
Exam Question # 44 Modified from Parent Q# RBS-NRC-459 Given the following conditions:
- The plant had been operating at 100% power
- A severe over-pressure transient resulted in ALL Safety Relief Valves (SRV) opening in the "relief" mode and then lifting in their "safety" mode
- RPV pressure peaked at 1200 psig
- All valves have closed (reseated) with the exception of one SRV that remains open in its "safety" mode
- The required actions of AOP-0035, "Safety Relief Valve Stuck Open", have been taken including scramming the reactor but the SRV has not closed.
Which of the following describes the resulting tailpipe temperature trend as the plant cools down and depressurizes through the stuck open SRV? (Assume containment pressure is 0 psig and remains constant.)
SRV tailpipe temperature will:
A. start at 260 °F, rise to approximately 290 °F and then will slowly fall following reactor pressure during the depressurization below 500 psig.
B. start at 525 °F and will slowly fall following reactor pressure during the depressurization.
C. start at 285 °F, rise to approximately 325 °F and then will slowly fall following reactor pressure during the depressurization below 500 psig.
D. start at 305 °F and will slowly fall following reactor pressure during the depressurization.
Answer: C
Exam Question # 51 Modified from Parent Q# RBS-OPS-3255 The "A" Standby Diesel Generator is operating in parallel with the offsite power supply.
If the operator takes the DG Voltage Regulator Control Switch to raise, which of the following indications should be showing the LARGEST change?
A. Frequency (HZ)
B. Real Load (KW)
C. Engine Speed (RPM)
D. Reactive Load (KVAR)
Answer: D
Exam Question # 56 Modified from Parent Q# RBS-NRC-168 If total feedwater flow drops below the reactor recirculation system interlock level, the Reactor Recirculation pumps will downshift to slow speed.
What is the PRIMARY reason for this interlock?
A. pump cavitation.
B. flow control valve cavitation.
C. excessive axial thrust on the pump.
D. inaccurate wide range level indication.
Answer: B
Exam Question # 60 Modified from Parent Q# RBS-OPS-06288 The primary means of hydrogen control following a LOCA utilizes:
A. Hydrogen Igniters B. Hydrogen Recombiners C. Containment Purge subsystem D. Drywell Purge subsystem Answer: A
Exam Question # 62 Modified from Parent Q# RBS-LOR-1252 The plant is operating at 80% power with EHC Pressure Regulator Channel A selected for pressure control. Pressure Regulator Channel B is in TEST.
Which one of the following describes the plant response if the Pressure Regulator Channel A Averaging Manifold Pressure transmitter fails to 0 psig?
A. Turbine control valves fully open, steam bypass valves fully open, reactor pressure lowers until MSIVs close.
B. Turbine control valves fully close, steam bypass valves fully open, reactor pressure rises until a reactor scram occurs.
C. Turbine control valves fully open, steam bypass valves remain closed, reactor pressure lowers until MSIVs close.
D. Turbine control valves fully close, steam bypass valves remain closed, reactor pressure rises until a reactor scram occurs.
Answer: D
Exam Question # 64 Modified from Parent Q# RBS-OPS-2307 The HVN Chilled Water system Supply and Return valves to Containment (HVN-MOV127, 128, 129, 130, 102) will AUTO-CLOSE upon __________.
A. RPV Level 1 (-143")
B. RPV Level 2 (-43")
C. Drywell to Annulus d/p greater than 12 inches D. Opening of Service Water supply and Return valves to Containment Answer: B
Exam Question # 77 Modified from Parent Q# RBS-OPS-06265 The plant has experienced an ATWS. The following conditions exist at P680:
All eight white scram solenoid lights are extinguished Annunciator P680-05-C08 SCRAM PILOT VLV AIR HEADER LOW PRESSURE is alarming SDV Vent and Drain valve position lights indicate all four valves are closed Approximately 20% of the withdrawn control rods fully inserted CRD cooling water differential pressure has been maximized ARI has been inititated Which of the following methods for alternate control rod insertion should be attempted next?
A. venting the scram air header.
B. resetting and reinitiating ARI.
C. removing the scram solenoid power fuses.
D. resetting the scram and intiating a manual scram.
Answer: D
Exam Question # 83 Modified from Parent Q# 2008 Audit Q# 25 Examination Outline Cross-
Reference:
1 Group #
2 K/A #
295015 AA2.02 Importance Rating 4.1 Proposed Question:
Following a Level 3 scram signal, the following conditions exist:
143 control rods indicate full-in 2 control rods are not full-in Reactor power indicates 0%
Which of the following concerning reactor status and required procedure implementation is correct?
- a. It can NOT be determined that the reactor will remain shutdown under all conditions without boron. Transition to EOP-0001A is required.
- b. It can be determined that the reactor will remain shutdown without boron, EOP-0001A is NOT applicable.
- c. It can NOT be determined that the reactor will remain shutdown under all conditions without boron, but with reactor power less than 5%, EOP-0001A is NOT applicable.
- d. It can NOT be determined that the reactor will remain shutdown under all conditions without boron, but no EOP entry condition exists.
Proposed Answer:
A.
Exam Question # 87 Modified from Parent Q# RBS-NRC-937 The plant is operating at 85% power. The Manual Scram Pushbutton Surveillance is being performed. After arming and depressing the last Manual Scram Pushbutton for DIV 4, the half scram is reset. However, a failure of the K14D relay contacts to reclose when re-energized results in the "B" RPS DIV 4 SCRAM SOV VALVES OPEN light above the DIV 4 Manual Scram Pushbutton on P680 remaining out. All other RPS scram solenoid valve white lights on P680 are lit.
If a loss of RPS Bus A occurs at this time, which one of the following is the expected response and appropriate action to be taken?
A. None of the control rods will scram. Transfer RPS Bus A to Alternate power per AOP-0010, Loss of RPS Bus.
B. Approximately 1/4 of the control rods will scram. Manually scram the reactor and enter AOP-0001 and AOP-0010.
C. Approximately 1/4 of the control rods will scram. Transfer RPS Bus A to Alternate power per AOP-0010, Loss of RPS Bus.
D. All of the control rods will scram. Manually scram the reactor and enter AOP-0001 and AOP-0010.
Answer: B
Proposed handouts for the Draft Written Exam submittal follow this coversheet.
CONTINUOUS USE ATTACHMENT 13 PAGE 2 OF 2 INITIATING STANDBY LIQUID CONTROL OSP-0053 REV - 022 PAGE 47 OF 74 STANDBY LIQUID CONTROL INJECTION REQUIREMENTS TANK LEVEL PRIOR TANK LEVEL AFTER TANK LEVEL AFTER TO INJECTION INJECTION OF 69 lb Boron INJECTION OF 166 lb Boron (approximately 16 min inj time)
(approximately 38 min inj time)
GAL GAL GAL NOTE WHEN tank level falls between values, THEN the smaller value should be used.
1531 905 0
1550 924 19 1600 974 69 1700 1074 169 1800 1174 269 1900 1274 369 2000 1374 469 2100 1474 569 2200 1574 669 2300 1674 769 2400 1774 869 2500 1874 969 2600 1974 1069 2700 2074 1169 2800 2174 1269 2900 2274 1369 3000 2374 1469 3100 2474 1569 3200 2574 1669 3300 2674 1769 3400 2774 1869 3500 2874 1969 3600 2974 2069 3700 3074 2169 3800 3174 2269 3900 3274 2369 4000 3374 2469 4100 3474 2569 4200 3574 2669
'328-2939797)
+
6-:)6&)2(78%8-32
78%8-3234)6%8-2+1%29%0
%&2361%034)6%8-2+463')(96)
()+6%()(+6-(
463')(96)291&)6
%34
6):-7-32291&)6
)JJIGXMZI(EXI
238)7-+2%896)7%6)32*-0)
-2()<-2+-2*361%8-32
'328-2939797)
%346):4%+)3*
8%&0)3*',%2+)7
0)88)6()7-+2%8-32
86%'/-2+291&)6
()8%-0)(()7'6-48-323*',%2+)7
%346)'%
%HHIHTVSGIHYVEPVIJIVIRGIXS7XIT
%HHIHGPEVMJ]MRKFYPPIXIHWXITWXS7XITERHEGPEVMJ]MRK
2SXIXS7XIT
'SVVIGXIHWIRXIRGIWXVYGXYVIMR7XIT
'328-2939797)
%346):4%+)3*
8%&0)3*'328)287 7)'8-32
4%+)23
496437)(-7'977-32
7=148317
%9831%8-'%'8-327
-11)(-%8)34)6%836%'8-327
79&7)59)2834)6%836%'8-327
6)*)6)2')7
'328-2939797)
%346):4%+)3*
496437)(-7'977-32
8LITYVTSWISJXLMWTVSGIHYVIMWXS
4VSZMHIMRWXVYGXMSRWMRXLIIZIRXSJEHIKVEHIHKVMHGSRHMXMSRSV)RXIVK]XVERWQMWWMSR
WYWTIRWMSRSJQSRMXSVMRKSJXLI)RXIVK]XVERWQMWWMSRKVMH
'VIEXIEGSRWMWXIRXQIGLERMWQJSVXMQIP]RSXMJMGEXMSRSJTSXIRXMEPSVHIZIPSTMRKKVMH
GLERKIWXLEXGSYPHMQTEGX)27SJJWMXITS[IVWYTTP]HIWMKRVIUYMVIQIRXW
4VSZMHIKYMHIPMRIWXS1EMR'SRXVSP6SSQ3TIVEXMSRWXSIRWYVIXLEXKVMHVIPMEFMPMX]MW
QEMRXEMRIH
)WXEFPMWLGSQQYRMGEXMSRWTVSXSGSPHYVMRKHIKVEHIHKVMHRSXMJMGEXMSRFIX[IIRXLI
7]WXIQ3TIVEXMSRW'IRXIVERHXLI1EMR'SRXVSP6SSQ3TIVEXMSRW7XEJJ
(IJMRMXMSRW
7]WXIQ3TIVEXMSRW'IRXIV73' 8LEXTEVXSJXLI)RXIVK]8VERWQMWWMSR
SVKERM^EXMSRVIWTSRWMFPIJSVSZIVEPPSTIVEXMSRERHQSRMXSVMRKSJXLI)RXIVK]
XVERWQMWWMSRKVMH
8VERWQMWWMSR3TIVEXMRK'IRXIV83' 8LEXTEVXSJ)RXIVK]8VERWQMWWMSR
SVKERM^EXMSRVIWTSRWMFPIJSVXLIHE]XSHE]STIVEXMSRERHQSRMXSVMRKSJXLI
PSGEPKVMH*SV6&74MRI&PYJJ
- ERG]4SMRX1EMRXIRERGI4SMRX3J'SRXEGX43' 6&7WMXITIVWSR[LSMW
XLIQEMRTSMRXSJGSRXEGXPMEMWSR FIX[IIR6&7ERH73'83'JSVQEXXIVW
GSRGIVRMRKMWWYIVIWSPYXMSR
3**0-2)1SRMXSVMRK8LITVSGIWWSJYWMRKHEMP]EREP]WIWJSVXLITYVTSWI
SJTVSNIGXMRK)27WMXITSWXXVMTZSPXEKIWHYVMRKXLITIVMSHSJMRXIVIWX-J
VIUYMVIHXLMWEPPS[WXLIETTPMGEXMSRSJGSVVIGXMZIQIEWYVIWERHRSXMJMGEXMSRXS
XLIEJJIGXIH)27WMXIW SJTSWXXVMTZSPXEKIWFIPS[XLIEPPS[EFPIPMQMXWSJXLEX
JEGMPMX]
320-2)1SRMXSVMRK8LITVSGIWWSJTVSZMHMRKFSXLRIEVVIEPXMQI
GSRXMRKIRG]EREP]WMWQSRMXSVMRKSJ)27TSWXXVMTTVSNIGXIHZSPXEKIWERH
VIEPXMQIQSRMXSVMRKSJTVIWIRXGSRHMXMSRW
- SPXEKI7YTTSVX(MVIGXMZIW1:%61IKE:SPX%QT6IEGXMZI HMVIGXMZIW
VIGIMZIHJVSQXLI73'83'XSQEMRXEMRXLIZSPXEKISJXLIKVMH(MVIGXMZIW
HMJJIVJVSQRSVQEPSVHIVWMRXLEXXLI][MPPGSRXEMRXLITLVEWI8LMWMWE
HMVIGXMZI
'328-2939797)
%346):4%+)3*
6IWTSRWMFMPMXMIW
73'7LMJX7YTIVZMWSVQSRMXSVWXLI)RXIVK]8VERWQMWWMSRKVMHERHTVSZMHIW
XMQIP]RSXMJMGEXMSRXSXLI6MZIV&IRH7XEXMSR1EMR'SRXVSP6SSQMJTVSNIGXIH
RYGPIEVSJJWMXITS[IVWYTTP]HIWMKRVIUYMVIQIRXWEVIRSXQEMRXEMRIH[MXLMR
WTIGMJMIHPMQMXW
1EMR'SRXVSP6SSQ3TIVEXMSRW7LMJX1EREKIV1'6371
'SQQYRMGEXMRK[MXLXLI73'7LMJX7YTIVZMWSV[LIRRSXMJMIHXLEXRIEVVIEP
XMQISRPMRIQSRMXSVMRKSVTVSNIGXIHRYGPIEVSJJWMXITS[IVWYTTP]HIWMKR
VIUYMVIQIRXWEVIRSXQEMRXEMRIH[MXLMRXLIWTIGMJMIHPMQMXW8LMW
VIWTSRWMFMPMX]MRGPYHIWWGLIHYPMRKER]RIGIWWEV]JSPPS[YTGEPPW[MXLXLI
73'7LMJX7YTIVZMWSV6IJ)27('
4IVJSVQMRMXMEPEWWIWWQIRXSJ8VERWQMWWMSRRSXMJMGEXMSRWERHMRMXMEXI
ETTVSTVMEXIEGXMSRWEWRIGIWWEV]8LMWVIWTSRWMFMPMX]MRGPYHIWMRMXMEXMSRSJ
'SRHMXMSR6ITSVXWERHTIVJSVQERGISJ3TIVEFMPMX](IXIVQMREXMSRWMR
EGGSVHERGI[MXLTPERXTVSGIHYVIW
1EMRXEMRWE[EVIRIWWSJXLIWMXIWTIGMJMGHIWMKRVIUYMVIQIRXWJSVSJJWMXI
TS[IVERHXLIFEWMWJSVXLSWIVIUYMVIQIRXWMRXLISTIVEXMSRSJXLIWXEXMSR
-RMXMEXIWETTVSTVMEXIEGXMSRWEWRIGIWWEV]MRSVHIVXSQEMRXEMRKVMHVIPMEFMPMX]
MREGGSVHERGI[MXLTVSGIHYVIWERHTVSXSGSP
'SQTP][MXLHMVIGXMZIWYRPIWWWYGLEGXMSRW[SYPHZMSPEXIWEJIX]
IUYMTQIRXSVVIKYPEXSV]SVWXEXYXSV]VIUYMVIQIRXW9RHIVXLIWI
GMVGYQWXERGIWXLI73'WLEPPFIMQQIHMEXIP]MRJSVQIHSJXLIMREFMPMX]XS
TIVJSVQXLIHMVIGXMZIWSXLEXXLI6IPMEFMPMX]'SSVHMREXSVQE]MQTPIQIRX
EPXIVREXIVIQIHMEPEGXMSRW
6IZMI[TVSGIHYVIWJSVTIVJSVQERGIERHSVW]WXIQGSRJMKYVEXMSR
VIEPMKRQIRXWIRWYVIZYPRIVEFMPMXMIWXSGSQQSRGEYWIERHGSQQSRQSHI
JEMPYVIWEVIIZEPYEXIHJSVGYVVIRXTPERXGSRHMXMSRWXSTVSXIGXWEJIX]WSYVGIW
ERHWEJIX]XVEMRW73)66IGSQQIRHEXMSR)QIVKIRG]4S[IV
6IPMEFMPMX] 6IJ
'328-2939797)
%346):4%+)3*
8EOIEGXMSRWEWRIIHIHHYVMRKIZIRXWSJKVMHMRWXEFMPMX]ERHZSPXEKI
HIKVEHEXMSRSVXLIKVMHSTIVEXSVWTVIHMGXMSRSJMRWYJJMGMIRXSJJWMXIZSPXEKI
PIZIPWJSPPS[MRKETPERXXVMTF]TPEGMRKWEJIX]W]WXIQWSRFEGOYTTS[IV
WYTTPMIWERHGSRWIVZEXMZIP]TPEGMRKXLITPERXMREWEJISTIVEXMRKSVWLYXHS[R
GSRHMXMSR8LIETTPMGEFPITVSGIHYVIWWLEPPFIYWIHXSQERYEPP]GSRJMKYVI
IPIGXVMGEPFYWIW[LIREYXSQEXMGFYWXVERWJIVWJEMPXSEGXYEXISV[LIRQERYEP
EPMKRQIRXSJIQIVKIRG]TS[IVMWRIGIWWEV]-JSJJWMXITS[IVMWPSWXXLI
XMQIP]VIWXSVEXMSRSJSJJWMXITS[IVERHVIWIXXMRKSJWEJIX]W]WXIQIPIGXVMGEP
WIUYIRGMRKIUYMTQIRXMWXLIQSWXWMKRMJMGERXSTIVEXSVEGXMSRXSQMXMKEXIGSVI
HEQEKI8LISTIVEXMRKGVI[WMQQIHMEXIJSGYWWLSYPHFIWXEFMPM^MRKXLI
TPERXFIJSVIGSRWMHIVEXMSRMWKMZIRXSVIXYVRMRKXLITPERXXSTS[IVSTIVEXMSR
73)66IGSQQIRHEXMSRWEFGH0SWW3J+VMH 6IJ
-*ER73'2SXMJMGEXMSRSJ320-2)1SRMXSVMRK8SSP2SX%ZEMPEFPISGGYVW8,)2
GPSWIP]QSRMXSVXLIZSPXEKIWERHJVIUYIRGMIWSR74-6)'VIGSVHIVSR,4ERH
EPEVQWHMWGYWWIHMR7IGXMSR8LMWHSIWRSXGSRWXMXYXIKVMHHIKVEHEXMSR
7=148317
8LI73'LEWRSXMJMIHXLI371'67XLEXKVMHHIKVEHEXMSRGYVVIRXP]I\\MWXWSVRSXMJMGEXMSR
XLEXTSWXXVMTSVEGXYEPW[MXGL]EVHZSPXEKIHSIWRSXWYTTSVXEGGMHIRXPSEHMRK
+VMH3WGMPPEXMSRWSJXLIQEMRKIRIVEXSVJVIUYIRG]ERHSVZSPXEKI
%RRYRGMEXSV4%,+6-(8639&0)
,MKL*VIUYIRG]
,^
0S[*VIUYIRG]
,^
0S[:SPXEKI
/Z
0S[ZSPXEKIEPEVQW
%RRYRGMEXSV4%+4*(78%<*1668<<76):308%+)03;
OZSPXW
%RRYRGMEXSV4%,4*(78%<*1668<<76':308%+)03;
ZSPXW
%RRYRGMEXSV4%+4*(78%<*1668<<76*03;:308%+)
OZSPXW
%RRYRGMEXSV4%,4*(78%<*1668<<76(03;:308%+)
ZSPXW
'328-2939797)
%346):4%+)3*
%9831%8-'%'8-327
2SRI
-11)(-%8)34)6%836%'8-327
2SRI
79&7)59)2834)6%836%'8-327 238) 7XITWQE]FITIVJSVQIHGSRGYVVIRXP]EWETTVSTVMEXI
-*%RRYRGMEXSV4%,+6-(8639&0)EPEVQW8,)2GSRXEGXXLI73'4MRI
&PYJJTVMQEV] SV83'&IEYQSRXFEGOYT XSHIXIVQMRIXLIVIEWSRERHI\\XIRXSJXLI
(IKVEHIH+VMH
4VMQEV]73'4MRI&PYJJ6MRKHS[R4LSRI*E\\
&EGOYT83'&IEYQSRX4LSRI*E\\
'SRXEGXXLI(YX]1EREKIV
238) 8LI1EMR+IRIVEXSV)QIVKIRG]1:%67PMQMXMW
1:%67XS1:%67
-*TSWWMFPI8,)2QEMRXEMRXLI1EMR+IRIVEXSV1:%67FIX[IIR1:%67ERH
1:%67TIV734
1EMRXEMRXLIKVMHZSPXEKIEXXLI6&7W[MXGL]EVHFIX[IIR/:ERH/:F]
%HNYWXMRK1:%67TIV7XIT
'SRXEGXMRKXLI73'SV83'JSVKVMHZSPXEKIEWWMWXERGI
'328-2939797)
%346):4%+)3*
-*MXMWHIXIVQMRIHXLEXKVMHZSPXEKIGERRSXFIQEMRXEMRIHEFSZI/:
8,)2TIVJSVQXLIJSPPS[MRK
'SRWYPX[MXL73'83'VIKEVHMRKWXEFMPMX]SJXLIKVMHRIEV6&7
-*73'83'MRHMGEXIWXLEXXLI*ERG]4SMRXMWWYJJMGMIRXP]WXEFPI8,)2
238)
-XMWTVIJIVVIHXLEX(MZ(+MWXVERWJIVVIHJMVWXERHXLI
HMZMWMSRXLEXLEW,:/VYRRMRKXVERWJIVVIHPEWXXSTVIZIRX
EPXIVREXMRK,:/X[MGI
4IVJSVQE2SVQEPWXEVXSJEPPXLVII)QIVKIRG](MIWIP+IRIVEXSVW
238)
-JXLIW]RGLVSWGSTIJSVXLI(MIWIP+IRIVEXSVW WLS[WIVVEXMG
QSZIQIRXXLIRXLIKVMHWLSYPHFIGSRWMHIVIHYRWXEFPIERH
W]RGLVSRM^MRKXLI(MIWIP+IRIVEXSVXSXLIKVMHWLSYPHFI
EZSMHIH
9WIXLIW]RGLVSWGSTIWYWIHJSVTEVEPPIPMRKXLI(MIWIP+IRIVEXSVWXSXLI
WEJIX]FYWWIWEWERMRWXERXERISYWMRHMGEXMSRSJMRWXEFMPMX]SRXLIKVMH
238)
%RYRWXEFPIKVMH[MPPVIWYPXMRW[MRKWMREXPIEWXSRISJXLI
JSPPS[MRKHEXETSMRXW
9WIXLIJSPPS[MRKXSXVIRHXLIKVMHWXEFMPMX]FIJSVITEVEPPIPMRKXLI(MIWIP
+IRIVEXSVXSXLIKVMHF]GSQTEVMRKXLIXVIRHW[MXLLMWXSVMGEPHEXE
MRWTIGXMRKJSVIVVEXMGFILEZMSVWYGLEWWYHHIRWTMOIWERHHMTW
-*XLI1EMR+IRIVEXSV:SPXEKI6IKYPEXSVMWMR%YXS8,)2XVIRHXLI
4(7HEXEJSV1EMR+IRIVEXSV1:%6W4(74SMRX74+)%
-*XLI1EMR+IRIVEXSV:SPXEKI6IKYPEXSVMWMR1ERYEP8,)2XVIRH
XLI4(7HEXEJSV1EMR+IRIVEXSV:SPXEKISYXTYX4(74SMRX
74+)%
8VIRH4(7HEXEJSVXLI1EMR8YVFMRI7TIIH4(74SMRX2)%
-*XLIKVMHMWZIVMJMIHWXEFPI8,)24EVEPPIPXLI)QIVKIRG](MIWIP
+IRIVEXSVW[MXLSJJWMXITS[IV%2(HMWGSRRIGXXLIFYWJVSQXLIKVMH
'328-2939797)
%346):4%+)3*
-*73'83'36TPERXMRHMGEXMSRWYWIHMRWXITMRHMGEXIXLEXXLI*ERG]
4SMRXMW238WYJJMGMIRXP]WXEFPI8,)2
)QIVKIRG]7XEVXIEGLHMIWIPKIRIVEXSV
- IVMJ]HMIWIPW]WXIQTEVEQIXIVWEVIRSVQEP
)RWYVIEPPMWSPEXMSRWEVIVIWIXJSVXLIETTPMGEFPIWEJIX]VIPEXIHFYWTVMSVXS
GSRXMRYMRKXSXLIRI\\XFYW
'%98-32
-*647MWFIMRKWYTTPMIHJVSQXLI%PXIVREXIWSYVGI8,)2HIIRIVKM^MRKXLIHMZMWMSREPWEJIX]
VIPEXIHFYW[MPPGEYWIE647LEPJ7'6%1ERH-RFSEVHSV3YXFSEVH&34MWSPEXMSR
238)
-XMWTVIJIVVIHXLEX(MZ(+MWXVERWJIVVIHJMVWXERHXLI
HMZMWMSRXLEXLEW,:/VYRRMRKXVERWJIVVIHPEWXXSTVIZIRX
EPXIVREXMRK,:/X[MGI
3TIRWYTTP]FVIEOIVXSEWMRKPIHMZMWMSREPWEJIX]VIPEXIHFYW
6IWXSVIMWSPEXMSRWERHW]WXIQWEWRIGIWWEV]
- IVMJ]EPEVQWGEYWIHF]PSWWSJTS[IVGPIEVYTSRTS[IVVIWXSVEXMSR
6IWXSVI6;'9ERH74'-*MWSPEXIHSRPSWWSJTS[IVXSPIEOHIXIGXMSR
6IWIXLEPJMWSPEXMSRWJSV6;'9ERH170(VEMRWTIV%34
%YXSQEXMG-WSPEXMSRW
6IWXEVX6EH1SRMXSVW
6IWIX647%PXIVREXI)4%&VIEOIVW
%PXIVREXI(MZMWMSRWSJ,:/MJRIGIWWEV]
6IWIX76:%GGSYWXMG1SRMXSVW(MZMWMSR
6IWIX&IEVMRK0MJX4YQTWJSPPS[MRKPSWWSJTS[IVTIV
%64%%(MZMWMSR
6IWXSVI+IRIVEXSV7IEP3MPXSRSVQEPPMRIYTTIV734+IRIVEXSV
7IEP3MP7]WXIQ(MZMWMSR
6ITIEXWXITXLVSYKLJSVVIQEMRMRKWEJIX]VIPEXIHFYWWIW
'328-2939797)
%346):4%+)3*
4IVJSVQ7844S[IV(MWXVMFYXMSR7]WXIQ3TIVEFMPMX]'LIGOXSZIVMJ]
STIVEFMPMX]SJWEJIX]W]WXIQFYWIW
6IJIVXSXLIJSPPS[MRK87JSV3TIVEFMPMX]
1SHIWSV%'7SYVGIW3TIVEXMRKERH(MWXVMFYXMSR7]WXIQW
3TIVEXMRK
1SHIWSV%'WSYVGI7LYXHS[RERH(MWXVMFYXMSR7]WXIQW7LYXHS[R
8LI371WLEPPTIVJSVQERMRMXMEPEWWIWWQIRXERHMRMXMEXIETTVSTVMEXIEGXMSRW[LIR
RSXMJMIH8LMWVIWTSRWMFMPMX]MRGPYHIWXLIJSPPS[MRK
7GLIHYPMRKER]RIGIWWEV]JSPPS[YTGEPPW[MXLXLI73'
-RMXMEXMRKE'SRHMXMSR6ITSVXERHTIVJSVQER3TIVEFMPMX](IXIVQMREXMSR
'SRXEGXMRK)RKMRIIVMRKJSVEWWMWXERGIMRIZEPYEXMRKKVMHGSRHMXMSRWERHSTXMSRW
-RVIWTSRWIXSE73'KVMHHIKVEHEXMSRRSXMJMGEXMSRXLI371WLSYPHTIVJSVQXLI
JSPPS[MRK
4VSQTXP]MRMXMEXIXLIVIUYIWXIHEGXMSRWQIKE[EXXWQIKEZEVWIXG MRVIWTSRWIXS
73'KVMHYVKIRG]HMVIGXMZI
4IVJSVQEVMWOEWWIWWQIRXYWMRK%(16MWO1EREKIQIRX4VSKVEQ
-QTPIQIRXEXMSRERH3R0MRI1EMRXIRERGI6MWO%WWIWWQIRX
8IVQMREXIERHSVWYWTIRHEPPEGXMZMXMIWXLEXQE]VIHYGIKIRIVEXMRKGETEFMPMX]GEYWIE
YRMXWLYXHS[RSVMQTEGXGVMXMGEPIPIGXVMGEPHMWXVMFYXMSR
238)
(MWGVIXMSRWLSYPHFIYWIHMRIZEPYEXMSRSJTPERXXIWXMRK
ERHSVSTIVEXMSREPEGXMZMXMIWXLEXVEMWIWXLIVMWOSJYRMX
PSWW1ERHEXSV]XIWXMRKERHSVSTIVEXMSREPEGXMZMXMIWQE]
FIEPPS[IHTVSZMHIHWYGLEGXMZMX]MWRIGIWWEV]HYIXSXMQI
GSRWXVEMRXW1EMRXIRERGIXLEXMWTIVJSVQIHSRYRMX
EY\\MPMEVMIWXSIRWYVIYRMXVIPMEFMPMX]FYXVEMWIWXLIVMWOSJ
YRMXPSWWVIUYMVIWIZEPYEXMSR
%ZSMHEGXMSRWXLEXVEMWITPERXVMWOW
1EMRXEMRSVVIXYVR)QIVKIRG](MIWIP+IRIVEXSVW)(+W XSEWXERHF]WXEXYWEWWSSR
EWTVEGXMGEP
'328-2939797)
%346):4%+)3*
1EMRXEMRKIRIVEXSVTEVEQIXIVWMREGGSVHERGI[MXL73'VIUYIWXWERHKIRIVEXSV
STIVEXMRKTVSGIHYVIW
(YVMRKRSVQEP[SVOMRKLSYVWRSXMJ]XLI7MXI*ERG]4SMRX1EMRXIRERGI4SMRX3J
'SRXEGX43' SJXLIGSRHMXMSR8LMWTIVWSR[MPPEGXEWETSMRXSJGSRXEGXJSVER]
EGXMSRWXSXEOITPEGIMRXLIW[MXGL]EVHSVXLITPERX3YXWMHIRSVQEP[SVOMRKLSYVWSV
MJXLI43'GERRSXFIGSRXEGXIH8,)23TIVEXMSRW[MPPFIXLITSMRXSJGSRXEGX
- IVMJ]EPP0MQMXMRK'SRHMXMSRWJSV3TIVEXMSR0'3W EVIIRXIVIH[LIRGSRHMXMSRW
VIUYMVI
- IVMJ]EPPEFRSVQEPTVSGIHYVIWEVIIRXIVIH[LIRGSRHMXMSRWVIUYMVI
1SRMXSVKVMHZSPXEKIERHJVIUYIRG]SRVIGSVHIV74-6)'SR,4ERH
ERRYRGMEXSV,4%,+6-(8639&0)ERHXEOIEGXMSREWHMVIGXIHF]
%64
-*RSXMJMIHF]XLI73'XLEXEREP]WMWMRHMGEXIWXLEXXLIKVMH[MPP238FIEFPIXS
TVSZMHIXLIVIUYMVIHTSWXXVMTZSPXEKIXSWYTTSVXSJJWMXITS[IVSTIVEFMPMX]MRXLIIZIRX
SJEVIEGXSVWGVEQKIRIVEXSVXVMT8,)2HIGPEVIXLISJJWMXITS[IVW]WXIQ
-234)6%&0)ERHXEOIXLIVIUYMVIHEGXMSRWXSIZEPYEXIXLIGSRHMXMSRERHSVVIXYVRXS
3TIVEFPIWXEXYW
-RMXMEXIE'SRHMXMSR6ITSVX
7]WXIQ3TIVEXMSRW'IRXIV1EMR'SRXVSP6SSQ-RXIVJEGI
8LI73'WLEPPTVSZMHIXLI1'6371[MXLIEVP][EVRMRKSJTSXIRXMEPSV
HIZIPSTMRKKVMHMWWYIWXLVSYKLHMVIGXRSXMJMGEXMSR8LMWRSXMJMGEXMSRHMWGYWWMSR
WLSYPHMRGPYHI73)66IGSQQIRHEXMSRF
G0SWW3J+VMH 6IJ
)\\TIGXIHHYVEXMSRSJHIKVEHIHGSRHMXMSR
%GXMSRWFIMRKXEOIRERHTPERRIHXSVIWXSVIKVMHXSEREGGITXEFPIGSRHMXMSR
)WXEFPMWLQIRXSJTIVMSHMGGSQQYRMGEXMSRYRXMPXLIKVMHMWVIWXSVIHXSXLI
HIWMVIHGSRHMXMSR
8LI73'[MPPRSXMJ]XLI371[LIRKVMHHIKVEHEXMSRI\\MWXWGYVVIRXP]36XLEX
GSRHMXMSRWEVITVSNIGXIHXSSGGYVEXEWTIGMJMGXMQI36XLEX)RXIVK]
XVERWQMWWMSRQSRMXSVMRKSJKVMHWXEFMPMX]LEWFIIRWYWTIRHIH
'328-2939797)
%346):4%+)3*
-RVIWTSRWIXSE73'KVMHHIKVEHEXMSRRSXMJMGEXMSRXLI371WLSYPHEZSMHTIVJSVQMRKXLI
JSPPS[MRK
-QTPIQIRXMRKEGXMSRWXLEXVEMWITPERXVMWOW
4EVEPPIPMRK)(+W[MXLYRWXEFPISJJWMXITS[IVWSYVGIWQE]GEYWIWIZIVIPSEHW[MRKW
ERHSZIVPSEHXLI)(+W
4VSEGXMZISTIVEXMSRSJTPERXIUYMTQIRXXLEXQE]VEMWITPERXVMWOWF]F]TEWWMRKSV
GMVGYQZIRXMRKEYXSQEXMGTVSXIGXMZIJIEXYVIW
6IJIVXSXLIJSPPS[MRKGSVTSVEXITVSGIHYVIW
)27(')278VERWQMWWMSR+VMH1SRMXSVMRK
238)
)27('%XXEGLQIRXMHIRXMJMIWXLISTIVEXMSREP
VIUYMVIQIRXWJSVXLI6&7SJJWMXITS[IVWYTTP]8LIWI
VIUYMVIQIRXWEVITEVXSJXLI6&7HIWMKRFEWMWERHPMGIRWMRK
FEWMW*EMPYVIXSQIIXXLIWIVIUYMVIQIRXWQE]VIRHIVXLI
SJJWMXITS[IVWYTTP]MRSTIVEFPIXLYWVIUYMVMRKXLISTIVEXMRK
6&7YRMXXSWLYXHS[R*EMPYVIXSQIIXXLIWIVIUYMVIQIRXW
QYWXFIMQQIHMEXIP]GSQQYRMGEXIHXS6&7ERHMXWSTIVEXMRK
WXEJJJSVSTIVEFMPMX]HIXIVQMREXMSR
)27('3JJ7MXI4S[IV7YTTP](IWMKR6IUYMVIQIRXW73)6
6IGSQQIRHEXMSR0SWW3J+VMH 6IJ
- MXLXLI6&7YRMXWSJJPMRIXLIO
- SJJWMXITS[IVWSYVGIWLSYPHFIGETEFPISJ
TVSZMHMRK1;ERH1:%6XS6&7JSVWXEVXYTSVJSVWEJIWLYXHS[RERH
HIWMKRFEWMWEGGMHIRXQMXMKEXMSR
6)*)6)2')7
)27(')278VERWQMWWMSR+VMH1SRMXSVMRK
)27('3JJ7MXI4S[IV7YTTP](IWMKR6IUYMVIQIRXW
73)66IGSQQIRHEXMSR)QIVKIRG]4S[IV6IPMEFMPMX]
73)66IGSQQIRHEXMSRF
G0SWW3J+VMH
73)66IGSQQIRHEXMSREFGH0SWW3J+VMH
73)66IGSQQIRHEXMSR0SWW3J+VMH
HAZARDS AND OTHER CONDITIONS AFFECTING PLANT SAFETY OPERATING MODES:
GENERAL EMERGENCY SITE AREA EMERGENCY ALERT NOUE SYSTEM MALFUNCTION OPERATING MODES:
GENERAL EMERGENCY SITE AREA EMERGENCY ALERT NOUE Loss of AC Pow SG1 Prolonged loss of all offsite and all onsite AC power to emergency busses Emergency Action Level(s):
- b. Either of the following:
Restoration of at least one emergency bus in < 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> is not likely OR SS1 Loss of all offsite and all onsite AC power to emergency busses for > 15 minutes Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition has exceeded, or will likely exceed, the applicable time.
1.
Loss of all offsite power and all onsite AC SA1 AC power capability to emergency busses reduced to a single power source for > 15 minutes such that any additional single failure would result in station blackout Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition has exceeded, or will likely exceed, the applicable time.
SU1 Loss of all offsite AC power to emergency busses for > 15 minutes Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition has exceeded, or will likely exceed, the applicable time.
1.
Loss of all offsite AC power to Div I and II 1
2 3
4 5
D 1
2 3
4 5
D Plant Modes (white boxes indicate applicable modes) 1 Power Operations 2
Startup 3
Hot Shutdown 4
Cold Shutdown 5
Refuel D
Defueled EMERGENCY CLASSIFICATION USER AID 1 MODES 1 - 3 ABNORMAL RADIATION LEVELS / RADIOLOGICAL EFFLUENT OPERATING MODES:
GENERAL EMERGENCY SITE AREA EMERGENCY ALERT NOUE Radi AG1 Offsite dose resulting from an actual or IMMINENT release of gaseous radioactivity > 1000 mR TEDE or 5000 mR thyroid CDE for the actual or projected duration of the release using actual meteorology Emergency Action Level: (1 or 2 or 3)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time. If dose assessment results are available, the classification should be based on EAL #2 instead of EAL #1. Do not delay declaration awaiting AS1 Offsite dose resulting from an actual or IMMINENT release of gaseous radioactivity > 100 mR TEDE or 500 mR thyroid CDE for the actual or projected duration of the release Emergency Action Level(s) (1 or 2 or 3)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time. If dose assessment results are available, the classification should be based on EAL #2 instead of EAL #1. Do not delay declaration awaiting AA1 Any release of gaseous or liquid radioactivity to the environment > 200 times the ODCM limit for > 15 minutes Emergency Action Level(s): (1 or 2 or 3)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the release duration has exceeded, or will likely exceed the applicable time. In the absence of data to the contrary, assume that the release duration has exceeded the applicable time if an ongoing release is AU1 Any release of gaseous or liquid radioactivity to the environment > 2 times the ODCM limit for > 60 minutes Emergency Action Level(s): (1 or 2 or 3)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the release duration has exceeded, or will likely exceed the applicable time. In the absence of data to the contrary, assume that the release duration has exceeded the applicable time if an ongoing release is detected and the release start time is unknown.
1 2
3 4
5 D
1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D EIP-2-001 CLASSIFICATION USER AID ATTACHMENT 10 PAGE 1 of 2 1 2 3 4 5 D Security HG1 HOSTILE ACTION resulting in loss of physical control of the facility Emergency Action Level(s): (1 or 2) 1.
A HOSTILE ACTION has occurred such that plant personnel are unable to operate equipment required to maintain safety functions OR 2.
A HOSTILE ACTION has caused failure of Spent Fuel Cooling Systems and HS1 HOSTILE ACTION within the PROTECTED AREA Emergency Action Level(s):
1.
A HOSTILE ACTION is occurring or has occurred within the PROTECTED AREA as reported by the RBS security shift supervision HA1 HOSTILE ACTION within the OWNER CONTROLLED AREA or airborne attack threat Emergency Action Level(s): (1 or 2) 1.
A HOSTILE ACTION is occurring or has occurred within the OWNER CONTROLLED AREA as reported by the RBS security shift supervision OR 2.
A validated notification from NRC of an HU1 Confirmed SECURITY CONDITION or threat which indicates a potential degradation in the level of safety of the plant Emergency Action Level(s):(1 or 2 or 3) 1.
A SECURITY CONDITION that does NOT involve a HOSTILE ACTION as reported by the RBS security shift supervision OR 2.
A credible site specific security threat notification 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D wer OR RPV level cannot be maintained
> -162 inches.
1.
Loss of all offsite power and all onsite AC power to Div I, II and III ENS busses for > 15 minutes or will likely exceed, the applicable time.
- 1. a. AC power capability to Div I and Div II ENS busses reduced to a single power source for > 15 minutes AND
- b. Any additional single failure will result in a station blackout 1.
Loss of all offsite AC power to Div I and II ENS busses for > 15 minutes Failure of Reactor Protecti SG3 Automatic scram and all manual actions fail to shutdown the reactor and indication of an extreme challenge to the ability to cool the core exists Emergency Action Level(s):
1.a.
An automatic scram failed to shutdown the reactor AND
- b. All manual actions do not shutdown the reactor as indicated by reactor power > 5%
AND c.
Either of the following exist or have occurred due to continued power generation:
SS3 Automatic scram fails to shutdown the reactor and the manual actions taken from the reactor control console are not successful in shutting down the reactor Emergency Action Level(s):
1.a. An automatic scram failed to shutdown the reactor AND
- b. Manual actions taken at the reactor control console do not shutdown the reactor as indicated by reactor power > 5%
SA3 Automatic scram fails to shutdown the reactor and the manual actions taken from the reactor control console are successful in shutting down the reactor Emergency Action Level(s):
- 1. a. An automatic scram failed to shutdown the reactor AND
- b. Manual actions taken at the reactor control console successfully shutdown the reactor as indicated by reactor power < 5%
iological Effluents dose assessment results.
1.
VALID reading on any of the radiation monitors in Table R1 > the GENERAL EMERGENCY reading for > 15 minutes OR 2.
Dose assessment using actual meteorology indicates doses > 1000 mR TEDE or 5000 mR thyroid CDE at or beyond the SITE BOUNDARY OR 3.
Field survey results indicate closed window dose rates >
1000 mR/hr expected to continue for > 60 minutes; or analyses of field survey samples indicate thyroid CDE >
5000 mR for one hour of inhalation, at or beyond the SITE BOUNDARY dose assessment results.
1.
VALID reading on any of the radiation monitors in Table R1 > the SITE AREA EMERGENCY reading for > 15 minutes OR 2.
Dose assessment using actual meteorology indicates doses
> 100 mR TEDE or 500 mR thyroid CDE at or beyond the SITE BOUNDARY OR 3.
Field survey results indicate closed window dose rates >
100 mR/hr expected to continue for > 60 minutes; or analyses of field survey samples indicate thyroid CDE >
500 mR for one hour of inhalation, at or beyond the SITE BOUNDARY detected and the release start time is unknown.
1.
VALID reading on any of the radiation monitors in Table R1 > the Alert reading for > 15 minutes OR 2.
For RMS-RE107 effluent monitor:
EITHER VALID reading > 200 times the alarm setpoint established by a current radioactivity discharge permit for > 15 minutes OR VALID reading > 1.27E-01 µCi/ml for > 15 minutes OR 3.
Confirmed sample analysis for gaseous or liquid releases indicate concentrations or release rates > 200 times the ODCM limit for > 15 minutes 1.
VALID reading on any of the radiation monitors in Table R1 > the NOUE reading for > 60 minutes OR 2.
VALID reading on RMS-RE107 effluent monitor > 2 times the alarm setpoint established by a current radioactivity discharge permit for > 60 minutes OR 3.
Confirmed sample analyses for gaseous or liquid releases indicate concentrations or release rates > 2 times the ODCM limit for >60 minutes AA2 Damage to irradiated fuel or loss of water level that has resulted or will result in the uncovering of irradiated fuel outside the reactor vessel Emergency Action Level(s): (1 or 2) 1.
A water level drop in the reactor refueling cavity, spent fuel pool or fuel transfer canal that will result in i
di t d f l b i
d AU2 UNPLANNED rise in plant radiation levels Emergency Action Level(s): (1 or 2)
- 1. a. UNPLANNED water level drop in a reactor refueling pathway as indicated by any of the following:
Water level drop in the reactor refueling cavity, spent fuel pool, or fuel transfer canal indication on Control R
P l 870 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D Spent Fuel Cooling Systems and IMMINENT fuel damage is likely for a freshly off-loaded reactor core in pool 2.
A validated notification from NRC of an airliner attack threat within 30 minutes of the site OR 3.
A validated notification from NRC providing information of an aircraft threat Discretionary HG2 Other conditions exist which in the judgment of the Emergency Director warrant declaration of a General Emergency Emergency Action Level(s):
1.
Other conditions exist which in the judgment of the Emergency Director indicate that events are in progress or have occurred which involve actual or IMMINENT substantial core degradation or melting with potential for loss of containment integrity or HOSTILE ACTION that results in an actual loss of physical control of the facility. Releases can be reasonably expected to exceed EPA Protective Action Guideline exposure levels offsite for more than the immediate site area HS2 Other conditions exist which in the judgment of the Emergency Director warrant declaration of a SITE AREA EMERGENCY Emergency Action Level(s):
1.
Other conditions exist which in the judgment of the Emergency Director indicate that events are in progress or have occurred which involve actual or likely major failures of plant functions needed for protection of the public or HOSTILE ACTION that results in intentional damage or malicious acts: (1) toward site personnel or equipment that could lead to the likely failure of or: (2) that prevent effective access to equipment needed for the protection of the public. Any releases are not expected to result in exposure levels which exceed EPA Protective Action Guideline exposure levels beyond the SITE BOUNDARY HA2 Other conditions exist which in the judgment of the Emergency Director warrant declaration of an ALERT Emergency Action Level(s):
1.
Other conditions exist which in the judgment of the Emergency Director indicate that events are in progress or have occurred which involve actual or likely potential substantial degradation of the level of safety of the plant or a security event that involves probable life threatening risk to site personnel or damage to site equipment because of HOSTILE ACTION.
Any releases are expected to be limited to small fractions of the EPA Protective Action Guideline exposure levels HU2 Other conditions exist which in the judgment of the Emergency Director warrant declaration of a NOUE Emergency Action Level(s):
1.
Other conditions exist which in the judgment of the Emergency Director indicate that events are in progress or have occurred which indicate a potential degradation of the level of safety of the plant or indicate a security threat to facility protection has been initiated.
No releases of radioactive material requiring offsite response or monitoring are expected unless further degradation of safety systems occurs 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D ion System p
g Core cooling is extremely challenged as indicated by RPV level cannot be restored and maintained > -186 inches OR Heat removal is extremely challenged as indicated by RPV pressure and Suppression Pool temperature cannot be maintained in the EOP Heat Capacity Temperature Limit (HCTL) Safe Zone Loss of DC Power SS4 Loss of all vital DC power for > 15 minutes Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition has exceeded, or will likely exceed, the applicable time.
1.
< 105 VDC on all vital DC busses > 15 minutes SS6 SA6 SU6 Abnormal Radiation Levels irradiated fuel becoming uncovered OR
- 2. A VALID reading on any of the following radiation monitors due to damage to irradiated fuel or loss of water level:
RMS-RE140 2000 mR/hr RMS-RE141 2000 mR/hr RMS-RE192 2000 mR/hr RMS-RE193 2000 mR/hr RMS-RE5A 1.64E+03 Ci/sec RMS-RE5B (GE) 5.29E-04 Ci/ml Room Panel 870 Personnel observation by visual or remote means.
AND
- b. UNPLANNED VALID area radiation monitor alarm on any of the following:
RMS-RE140 RMS-RE141 RMS-RE192 RMS-RE193 OR 2.
UNPLANNED VALID area radiation monitor readings or survey results indicate a rise by a factor of 1000 over normal* levels NOTE: For area radiation monitors with ranges incapable of measuring 1000 times normal* levels, classification shall be based on VALID full scale indications unless surveys confirm that area radiation levels are below 1000 times normal* within 15 minutes of the area radiation monitor indications going full scale.
- Normal can be considered the highest reading in the past 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> excluding the current peak value.
AA3 Rise in radiation levels within the facility that impedes Control Room Evacuation HS3 Control room evacuation has been initiated and plant control cannot be established Emergency Action Level(s):
- 1. a. Control room evacuation has been initiated AND
- b. Control of the plant cannot be established in accordance with AOP-0031, Shutdown from Outside the Main Control Room, within 15 minutes HA3 Control room evacuation has been initiated Emergency Action Level(s):
1.
AOP-0031, Shutdown from Outside the Main Control Room requires Control Room evacuation Fire HA4 FIRE or EXPLOSION affecting the operability of plant safety systems required to establish or maintain safe shutdown Emergency Action Level(s):
1.
FIRE or EXPLOSION resulting in VISIBLE DAMAGE to any of the structures or areas in Table H2 containing safety systems or components or Control Room indication of degraded performance of those safety systems HU4 FIRE within the PROTECTED AREA not extinguished within 15 minutes of detection or EXPLOSION within the PROTECTED AREA Emergency Action Level(s): (1 or 2)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the duration has exceeded, or will likely exceed, the applicable time.
1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D BOUNDARY Table R1 EAL THRESHOLD Method GENERAL DRMS Threshold SITE AREA DRMS Threshold ALERT DRMS Threshold NOUE DRMS Threshold Main Plant Primary Secondary 4GE125 4.70E+08 Ci/sec N/A 4GE125 4.70E+07 Ci/sec N/A 4GE125 3.06E+07 Ci/sec 1GE126 2.82E-01 Ci/ml 4GE125 3.06E+05 Ci/sec 1GE126 5.26E-03 Ci/ml FB Vent Primary Secondary 4GE005 6.70E+07 Ci/sec N/A 4GE005 6.70E+06 Ci/sec N/A 4GE005 2.19E+06 Ci/sec 5GE005 2.82E-01 Ci/ml 4GE005 2.19E+04 Ci/sec 5GE005 4.65E-03 Ci/ml RW Vent P i 4GE006 2 58E+06 Ci/sec 4GE006 2 58E+04 Ci/sec Loss of Annunciation / Indication Inability to monitor a SIGNIFICANT TRANSIENT in progress Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition has exceeded, or will likely exceed, the applicable time.
- 1. a. UNPLANNED loss of > approximately 75%
of the following for > 15 minutes:
Control Room safety system annunciation OR Control Room safety system indication AND
- b. A SIGNIFICANT TRANSIENT is in progress AND
- c. Compensatory indications are unavailable UNPLANNED loss of safety system annunciation or indication in the control room with either (1) a SIGNIFICANT TRANSIENT in progress, or (2) compensatory non-alarming indicators are not available Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition has exceeded, or will likely exceed, the applicable time.
- 1. a. UNPLANNED loss of > approximately 75%
of the following for > 15 minutes:
Control Room safety system annunciation OR Control Room safety system indication AND
- b. Either of the following:
A SIGNIFICANT TRANSIENT is in progress OR Compensatory indications unavailable UNPLANNED loss of safety system annunciation or indication in the Control Room for > 15 minutes Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition has exceeded, or will likely exceed, the applicable time.
1.
UNPLANNED loss of > approximately 75%
of the following for > 15 minutes:
- a. Control Room safety system annunciation OR
- b. Control Room safety system indication operation of systems required to maintain plant safety functions Emergency Action Level: (s) 1.
Dose rate > 15 mR/hr in any of the following areas requiring continuous occupancy to maintain plant safety functions:
Main Control Room CAS 1.
FIRE not extinguished within 15 minutes of Control Room notification or verification of a Control Room FIRE alarm in any Table H2 structure or area OR
- 2. EXPLOSION within the PROTECTED AREA Toxic or Flammable Gass HA5 Access to a VITAL AREA is prohibited due to toxic, corrosive, asphyxiant or flammable gases which jeopardize operation of operable equipment required to maintain safe operations or safely shutdown the reactor Emergency Action Level(s):
NOTE: If the equipment in the stated area was already inoperable, or out of service, before the event occurred, then this EAL should not be declared as it will have no adverse impact on the ability of the plant to safely operate or safely shutdown beyond that already allowed by Technical Specifications at the time of the event.
HU5 Release of toxic, corrosive, asphyxiant or flammable gases deemed detrimental to NORMAL PLANT OPERATIONS Emergency Action Level(s) (1 or 2) 1.
Toxic, corrosive, asphyxiant or flammable gases in amounts that have or could adversely affect NORMAL PLANT OPERATIONS OR 2.
Report by West Feliciana Parish for evacuation or sheltering of site personnel based on an offsite event 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D Primary Secondary N/A N/A 4GE006 2.58E+06 Ci/sec 5GE006 6.84E-02 Ci/ml 4GE006 2.58E+04 Ci/sec 5GE006 6.84E-04 Ci/ml FISSION PRODUCT BARRIER OPERATING MODES:
GENERAL EMERGENCY SITE AREA EMERGENCY ALERT NOUE FPB Loss / Potential Loss FG1 Loss of ANY two barriers AND loss or potential loss of third barrier Emergency Action Level(s):
- 1. Loss of any two barriers AND Loss or potential loss of the third barrier FS1 Loss or potential loss of ANY two barriers Emergency Action Level(s):
1.
Loss or potential loss of any two barriers FA1 ANY loss or ANY potential loss of EITHER fuel clad or RCS Emergency Action Level(s):
- 1. Any loss or any potential loss of fuel clad OR Any loss or any potential loss of RCS FU1 ANY loss or ANY potential loss of containment Emergency Action Level(s):
- 1. Any loss or any potential loss of containment FUEL CLAD (FC) Barrier REACTOR COOLANT SYSTEM (RC) Barrier PRIMARY CONTAINMENT (PC) Barrier Parameter Loss Potential Loss Parameter Loss Potential Loss Parameter Loss Potential Loss FC1 Primary coolant activity level Coolant activity
> 300 µCi/gm dose equivalent I131 None RC1 Drywell pressure Drywell pressure > 1.68 psid with indications of reactor coolant leak in drywell.
None PC1 Primary containment conditions
- 1. Rapid unexplained loss of PC pressure following initial pressure rise OR
- 1. PC pressure > 15 psig and rising OR 2 a PC hydrogen in the Compensatory indications unavailable RCS Leakage SU7 RCS leakage Emergency Action Level(s): (1 or 2)
NOTE: A relief valve that operates and fails to close per design should be considered applicable if the relief valve cannot be isolated.
1.
Unidentified or pressure boundary leakage > 10 gpm OR 2.
Identified leakage > 35 gpm Loss of C SU8 Loss of all onsite or offsite communication capabilities Emergency Action Level(s): (1 or 2) 1.
Loss of all of the following onsite communications methods affecting the ability to perform routine operations:
Plant radio system l
i 1
2 3
4 5
D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D ses 1.
Access to Main Control Room, Auxiliary Building, or 95 Control Building is prohibited due to toxic, corrosive, asphyxiant or flammable gases which jeopardize operation of systems required to maintain safe operations or safely shutdown the reactor HA6 Natural or destructive phenomena affecting VITAL AREAS Emergency Action Level(s): (1 or 2 or 3 or 4 or 5 or 6) 1.a. Seismic event > Operating Basis Earthquake (OBE) as indicated by:
Annunciator Seismic Tape Recording System Start (P680-02A-D06)
AND Event Indicator on ERS-NBI-102 is white AND Receipt of EITHER 1 OR 2:
1.
Annunciator Seismic Event High (P680-02A-C06)
HU6 Natural or destructive phenomena affecting the PROTECTED AREA Emergency Action Level(s):(1 or 2 or 3 or 4 or 5) 1.
Seismic event identified by any 2 of the following:
Seismic event confirmed by activated seismic switch as indicated by receipt of EITHER a OR b:
a.
Annunciator Seismic Tape Recording SYS Start (P680-02A-D06)
- b. Event Indicator on ERS-NBI-102 is white Earthquake felt in plant 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D activity level OR
- 2. PC pressure response not consistent with LOCA conditions
- 3. RPV pressure and suppression pool temperature cannot be maintained below the HCTL FC2 Reactor vessel water level RPV water level cannot be restored and maintained above
-186 inches RPV water level cannot be restored and maintained above -162 inches or cannot be determined RC2 Reactor vessel water level RPV water level cannot be restored and maintained above -162 inches or cannot be determined None PC2 Reactor vessel water level None Entry into PC flooding procedures SAP-1 and SAP-2 FC3 Primary containment radiation monitors Containment radiation monitor RMS-RE16 reading > 3,000 R/hr None RC3 RCS Leak Rate
- 1. UNISOLABLE main steam line break as indicated by the failure of both MSIVs in any one line to close AND High MSL flow annunciator (P601-19A-A2)
- 2. UNISOLABLE RCS leakage outside PC as indicated by exceeding either of the following:
- a. Max Normal Operating Temperature (Table F2)
PC3 Primary containment isolation failure or bypass
- 1. a. Failure of both valves in any one line to close AND
- b. Direct downstream pathway to the environment exists after PC isolation OR
- 2. Intentional PC venting per EOPs or SAPs None ommunication Plant paging system Sound powered phones In-plant telephones OR 2.
Loss of all of the following offsite communications methods affecting the ability to perform offsite notifications:
All telephones NRC phones State of Louisiana Radio Offsite notifications system and hotline Cladding Degradation SU9 Fuel clad degradation Emergency Action Level(s): (1 or 2) 1.
Offgas pre-treatment radiation monitor reading
> the Table S1 Dose Rate Limit for the actual indicated offgas flow indicating fuel clad degradation > T.S. allowable limits OR 2.
Reactor coolant sample activity value indicating fuel clad degradation > T.S. allowable limits
> 4.0 µCi/gm dose equivalent I-131 OR
> 0.2 µCi/gm dose equivalent I-131 for > 48 Natural or Destructive Phenomena (P680-02A-C06)
- 2. Annunciator Seismic Event High-High (P680-02A-B06) AND amber light(s) on panel NBI-101 AND
- b. Earthquake confirmed by any of the following:
Earthquake is felt in plant National Earthquake Center Control Room indication of degraded performance of systems required for safe shutdown of the plant OR 2.
Tornado striking resulting in VISIBLE DAMAGE to any of the Table H2 structures or areas containing safety systems or components or Control Room indication of degraded performance of those safety systems OR 3.
Internal flooding in Auxiliary Building 70 ft elevation resulting in an electrical shock hazard that precludes access to operate or monitor safety equipment or Control Room indication of degraded performance of those safety systems OR Earthquake felt in plant National Earthquake Center OR 2.
Tornado striking within the PROTECTED AREA boundary OR
- 3. Internal flooding that has the potential to affect safety related equipment required by Technical Specifications for the current operating mode in any Table H1 area OR
- 4. Turbine failure resulting in casing penetration or damage to turbine or generator seals OR
- 5. Severe weather or hurricane conditions with indication of SUSTAINED high winds > 74 mph within the PROTECTED AREA boundary Table H2 Structures Containing Functions or Systems Required for Safe Shutdown Reactor Building Standby Cooling Tower Auxiliary Building Diesel Generator Building Control Building Tunnels (B, D, E, F, G)
Table H1 Uncontrolled Flooding Threshold Area Water Level Affected Location /
Parameter Max Safe Operating Value / Indicator Aux Bldg 6 inches above floor 1 2 3 4 5 D Table S1 Flow (cfm)
Dose Rate (mR/hr)
<15 9000
>15-17 8000
>17-20 7000
>20-25 5000
>25-30 4000
>30-60 2000 OR
- b. Max Normal Area Radiation (Table F2)
- 3. UNISOLABLE RCS leakage outside PC as indicated by exceeding either of the following:
- a. Max Safe Operating Temperature (Table F1)
- b. Max Safe Area Radiation (Table F1)
RC4 Drywell radiation Drywell radiation monitor RMS-RE20 reading > 100 R/hr due to reactor coolant leakage None PC4 Primary containment radiation monitors None Containment radiation monitor RMS-RE16 reading
> 10,000 R/hr FC4 Emergency Director judgment Any condition in the opinion of the Emergency Director that indicates loss of the Fuel Clad barrier Any condition in the opinion of the Emergency Director that indicates potential loss of the Fuel Clad barrier RC5 Emergency Director judgment Any condition in the opinion of the Emergency Director that indicates loss of the RCS barrier Any condition in the opinion of the Emergency Director that indicates potential loss of the RCS barrier PC5 Emergency Director judgment Any condition in the opinion of the Emergency Director that indicates loss of the Primary Containment barrier Any condition in the opinion of the Emergency Director that indicates potential loss of the Primary Containment barrier TABLE F1 TABLE F2
µ g
q hours Inadvertent Criticality SU10 Inadvertent criticality Emergency Action Level(s):
1.
UNPLANNED sustained positive period observed on nuclear instrumentation TECH SPEC Time Limit Ex SU11 Inability to reach required operating mode within Technical Specification limits Emergency Action Level(s):
1.
Plant is not brought to required operating mode within Technical Specifications LCO Action Statement time EVENTS RELATED TO ISFSI OPERATING MODES:
4.
Turbine failure-generated PROJECTILES resulting in VISIBLE DAMAGE to or penetration of any of the Table H2 structures or areas containing safety systems or components or Control Room indication of degraded performance of those safety systems OR 5.
Vehicle crash resulting in VISIBLE DAMAGE to any of the Table H2 structures or areas containing safety systems or components or Control Room indication of degraded performance of those safety systems OR 6.
Hurricane or high SUSTAINED wind conditions > 74 mph within the PROTECTED AREA boundary and resulting in VISIBLE DAMAGE to any of the Table H2 structures or areas containing safety systems or components or Control Room indication of degraded performance of those safety systems 1 2 3 4 5 D 1 2 3 4 5 D 1
2 3
4 5
D Building G)
Fuel Building Aux Bldg Crescent Area 70 EL 6 inches above floor (must be verified locally)
HPCS Room 70EL 4 inches above floor (P870-51A-G4)
RHR A Room 70EL 4 inches above floor (P870-51A-G4)
RHR B Room 70EL 4 inches above floor (P870-51A-G4)
RHR C Room 70EL 4 inches above floor (P870-51A-G4)
LPCS Room 70EL 4 inches above floor (P870-51A-G4)
RCIC Room 70EL 4 inches above floor (P870-51A-G4)
>60-140 1000
>140-200 700 PC 3 Loss of Primary Containment Parameter Area Temperature Max Safe Operating Value Area Radiation Level DRMS Grid 2 Max Safe Operating Value RHR A equip area 200º F 1213 9.5E+03 mR/hr RHR B equip area 200º F 1214 9.5E+03 mR/hr RHR C equip area N/A 1215 9.5E+03 mR/hr RCIC room 200º F 1219 9.5E+03 mR/hr MSL Tunnel 200º F N/A RWCU pump room 1 (A) / 2 (B) 200º F N/A RC 3 Potential Loss of RCS Parameter Area Temperature (isolation temperature alarm)
Area Radiation Level DRMS Grid 2 Max Normal Operating Value RHR A equip area 117º F (P601-20A-B4) 1213 8.2E+01 mR/hr RHR B equip area 117º F (P601-20A-B4) 1214 8.2E+01 mR/hr RHR C equip area N/A 1215 8.2E+01 mR/hr RCIC room 182º F (P601-21A-B6) 1219 1.20E+02 mR/hr MSL Tunnel 173º F (P601-19A-A1/A3/B1/B3)
N/A RWCU pump room 1 (A) / 2 (B) 165º F (P680-1A-A2/B2)
N/A xceeded GENERAL EMERGENCY SITE AREA EMERGENCY ALERT NOUE Cask Damage E-HU1 Damage to a loaded cask CONFINEMENT BOUNDARY Emergency Action Level(s):
1.
Damage to a loaded cask CONFINEMENT BOUNDARY 1 2 3 4 5 D EIP-2-001 ATT 10 USER AID 1 Revision D EIP-2-001 REV - 24 PAGE 157 of 158
EMERGENCY CLASSIFICATION USER AID 2 MODES 4, 5, and Defueled COLD SHUTDOWN / REFUELING OPERATING MODES:
GENERAL EMERGENCY SITE AREA EMERGENCY ALERT NOUE CG1 Loss of RCS/RPV inventory affecting fuel clad integrity with containment challenged Emergency Action Level(s): (1 or 2)
CS1 Loss of RCS/RPV inventory affecting core decay heat removal capability Emergency Action Level(s): (1 or 2 or 3)
CA1 Loss of RCS inventory Emergency Action Level(s): (1 or 2)
NOTE: The Emergency Director should not wait CU1 RCS leakage Emergency Action Level(s):
NOTE: The Emergency Director should not wait 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D ATTACHMENT 10 PAGE 2 of 2 EIP-2-001 CLASSIFICATION USER AID 1
2 3
4 5
D Plant Modes (white boxes indicate applicable modes) 1 Power Operations 2
Startup 3
Hot Shutdown 4
Cold Shutdown 5
Refuel D
Defueled ABNORMAL RADIATION LEVELS / RADIOLOGICAL EFFLUENT OPERATING MODES:
GENERAL EMERGENCY SITE AREA EMERGENCY ALERT NOUE AG1 Offsite dose resulting from an actual or IMMINENT release of gaseous radioactivity > 1000 mR TEDE or 5000 mR thyroid CDE for the actual or projected duration of the release using actual meteorology AS1 Offsite dose resulting from an actual or IMMINENT release of gaseous radioactivity > 100 mR TEDE or 500 mR thyroid CDE for the actual or projected duration of the release AA1 Any release of gaseous or liquid radioactivity to the environment > 200 times the ODCM limit for > 15 minutes Emergency Action Level(s): (1 or 2 or 3)
AU1 Any release of gaseous or liquid radioactivity to the environment > 2 times the ODCM limit for > 60 minutes Emergency Action Level(s): (1 or 2 or 3)
NOTE: The Emergency Director should not wait until the 1
2 3
4 5
D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D HAZARDS AND OTHER CONDITIONS AFFECTING PLANT SAFETY OPERATING MODES:
GENERAL EMERGENCY SITE AREA EMERGENCY ALERT NOUE 1
2 3
4 5
D HG1 HOSTILE ACTION resulting in loss of physical control of the facility Emergency Action Level(s): (1 or 2)
HS1 HOSTILE ACTION within the PROTECTED AREA Emergency Action Level(s):
HA1 HOSTILE ACTION within the OWNER CONTROLLED AREA or airborne attack threat HU1 Confirmed SECURITY CONDITION or threat which indicates a potential degradation in the level of safety of the plant 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D Loss of RCS/RPV Inventory EmergencyAction Level(s): (1 or 2)
- b. Any containment challenge indication in Table C1 OR
- 2. a. RCS level cannot be monitored with core uncovery indicated by any of the following for > 30 minutes:
- RMS-RE16 reading > 100 R/hr
- Erratic source range monitor indication
- Unexplained rise in floor or equipment sump level, Suppression Pool level, vessel make-up rate or observation of leakage or inventory loss AND
- b. Any containment challenge indication in Table C1 NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time.
1.
With CONTAINMENT CLOSURE not established, UNPLANNED RPV level < -49 inches OR 2.
With CONTAINMENT CLOSURE established, RPV level < -162 inches (TAF)
- 3. RCS level cannot be monitored for >
30 minutes with a loss of RCS inventory as indicated by any of the following:
RMS-RE16 reading > 100 R/hr Erratic Source Range Monitor indication Unexplained rise in floor or equipment sump level, Suppression Pool level, vessel make-up rate or observation of leakage or inventory loss NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time.
1.
UNPLANNED loss of RCS inventory as indicated by RPV level < -43 inches (Level 2)
OR 2.
RCS level cannot be monitored for > 15 minutes with a loss of RCS inventory as indicated by an unexplained rise in floor or equipment sump level, Suppression Pool level, vessel make-up rate or observation of leakage or inventory loss NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time.
1.
RCS leakage results in the inability to maintain or restore RPV level > +9.7 inches (Level 3) for > 15 minutes Table C1 Containment Challenge Indications Radiological Effluents Emergency Action Level: (1 or 2 or 3)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time. If dose assessment results are available, the classification should be based on EAL #2 instead of EAL #1. Do not delay declaration awaiting dose assessment results.
1.
VALID reading on any of the radiation monitors in Table R1 > the GENERAL EMERGENCY reading for > 15 minutes OR 2.
Dose assessment using actual meteorology indicates doses > 1000 mR TEDE or 5000 mR thyroid CDE at or beyond the SITE BOUNDARY OR 3.
Field survey results indicate closed window dose rates >
1000 mR/hr expected to continue for > 60 minutes; or analyses of field survey samples indicate thyroid CDE >
5000 mR for one hour of inhalation, at or beyond the SITE BOUNDARY Emergency Action Level(s) (1 or 2 or 3)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time. If dose assessment results are available, the classification should be based on EAL #2 instead of EAL #1. Do not delay declaration awaiting dose assessment results.
1.
VALID reading on any of the radiation monitors in Table R1 > the SITE AREA EMERGENCY reading for > 15 minutes OR 2.
Dose assessment using actual meteorology indicates doses
> 100 mR TEDE or 500 mR thyroid CDE at or beyond the SITE BOUNDARY OR 3.
Field survey results indicate closed window dose rates >
100 mR/hr expected to continue for > 60 minutes; or analyses of field survey samples indicate thyroid CDE >
500 mR for one hour of inhalation, at or beyond the SITE BOUNDARY NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the release duration has exceeded, or will likely exceed the applicable time. In the absence of data to the contrary, assume that the release duration has exceeded the applicable time if an ongoing release is detected and the release start time is unknown.
1.
VALID reading on any of the radiation monitors in Table R1 > the Alert reading for > 15 minutes OR 2.
For RMS-RE107 effluent monitor:
EITHER VALID reading > 200 times the alarm setpoint established by a current radioactivity discharge permit for > 15 minutes OR VALID reading > 1.27E-01 µCi/ml for > 15 minutes OR 3.
Confirmed sample analysis for gaseous or liquid releases indicate concentrations or release rates > 200 times the ODCM limit for > 15 minutes applicable time has elapsed, but should declare the event as soon as it is determined that the release duration has exceeded, or will likely exceed the applicable time. In the absence of data to the contrary, assume that the release duration has exceeded the applicable time if an ongoing release is detected and the release start time is unknown.
1.
VALID reading on any of the radiation monitors in Table R1 > the NOUE reading for > 60 minutes OR 2.
VALID reading on RMS-RE107 effluent monitor > 2 times the alarm setpoint established by a current radioactivity discharge permit for > 60 minutes OR 3.
Confirmed sample analyses for gaseous or liquid releases indicate concentrations or release rates > 2 times the ODCM limit for > 60 minutes Security Emergency Action Level(s): (1 or 2) 1.
A HOSTILE ACTION has occurred such that plant personnel are unable to operate equipment required to maintain safety functions OR 2.
A HOSTILE ACTION has caused failure of Spent Fuel Cooling Systems and IMMINENT fuel damage is likely for a freshly off-loaded reactor core in pool Emergency Action Level(s):
1.
A HOSTILE ACTION is occurring or has occurred within the PROTECTED AREA as reported by the RBS security shift supervision Emergency Action Level(s): (1 or 2) 1.
A HOSTILE ACTION is occurring or has occurred within the OWNER CONTROLLED AREA as reported by the RBS security shift supervision OR 2.
A validated notification from NRC of an airliner attack threat within 30 minutes of the site Emergency Action Level(s):(1 or 2 or 3) 1.
A SECURITY CONDITION that does NOT involve a HOSTILE ACTION as reported by the RBS security shift supervision OR 2.
A credible site specific security threat notification OR 3.
A validated notification from NRC providing information of an aircraft threat Discretionary HG2 Other conditions exist which in the judgment of the Emergency Director warrant declaration of a General Emergency Emergency Action Level(s):
1.
Other conditions exist which in the judgment of the Emergency Director indicate that events are in progress or have occurred which involve actual or IMMINENT substantial core degradation or melting with potential for loss of containment integrity or HOSTILE ACTION that results in an actual loss of HS2 Other conditions exist which in the judgment of the Emergency Director warrant declaration of a SITE AREA EMERGENCY Emergency Action Level(s):
1.
Other conditions exist which in the judgment of the Emergency Director indicate that events are in progress or have occurred which involve actual or likely major failures of plant functions needed for protection of the public or HOSTILE ACTION that results in intentional damage or malicious acts: (1)
HA2 Other conditions exist which in the judgment of the Emergency Director warrant declaration of an ALERT Emergency Action Level(s):
1.
Other conditions exist which in the judgment of the Emergency Director indicate that events are in progress or have occurred which involve actual or likely potential substantial degradation of the level of safety of the plant or a security event that involves probable life threatening risk to site personnel or damage to HU2 Other conditions exist which in the judgment of the Emergency Director warrant declaration of a NOUE Emergency Action Level(s):
1.
Other conditions exist which in the judgment of the Emergency Director indicate that events are in progress or have occurred which indicate a potential degradation of the level of safety of the plant or indicate a security threat to facility protection has been initiated.
No releases of radioactive material requiring 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D Loss of RCS/RPV Inventory CU2 UNPLANNED loss of RCS/RPV inventory Emergency Action Level(s): (1 or 2)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time.
- 1. UNPLANNED RCS level drop as indicated by either of the following:
- a. RCS water level drop below the RPV flange for > 15 minutes when the RCS level band is established above the RPV flange OR
- b. RCS water level drop below the RPV level band for > 15 minutes when the RCS level band is established below the RPV flange CONTAINMENT CLOSURE not established Explosive mixture inside containment UNPLANNED rise in containment pressure Secondary containment area radiation monitor above EOP Max Safe Operating Value below:
Area DRMS Grid 2 Max Safe Operating Value RHR Equip Rm A 1213 9.5E+03 mR/hr RHR Equip Rm B 1214 9.5E+03 mR/hr RHR Equip Rm C 1215 9.5E+03 mR/hr 1 2 3 4 5 D Abnormal Radiation Levels AA2 Damage to irradiated fuel or loss of water level that has resulted or will result in the uncovering of irradiated fuel outside the reactor vessel Emergency Action Level(s): (1 or 2) 1.
A water level drop in the reactor refueling cavity, spent fuel pool or fuel transfer canal that will result in irradiated fuel becoming uncovered OR
- 2. A VALID reading on any of the following radiation monitors due to damage to irradiated fuel or loss of water level:
RMS-RE140 2000 mR/hr RMS-RE141 2000 mR/hr RMS-RE192 2000 mR/hr RMS-RE193 2000 mR/hr RMS-RE5A 1.64E+03 Ci/sec RMS-RE5B (GE) 5.29E-04 Ci/ml AU2 UNPLANNED rise in plant radiation levels Emergency Action Level(s): (1 or 2)
- 1. a. UNPLANNED water level drop in a reactor refueling pathway as indicated by any of the following:
Water level drop in the reactor refueling cavity, spent fuel pool, or fuel transfer canal indication on Control Room Panel 870 Personnel observation by visual or remote means.
AND
- b. UNPLANNED VALID area radiation monitor alarm on any of the following:
RMS-RE140 RMS-RE141 RMS-RE192 RMS-RE193 OR 2.
UNPLANNED VALID area radiation monitor readings or survey results indicate a rise by a factor of 1000 over normal* levels NOTE: For area radiation monitors with ranges incapable of measuring 1000 times normal* levels, classification shall be based on VALID full scale indications unless surveysconfirm that area radiation levels are below 1 2 3 4 5 D 1 2 3 4 5 D ACTION that results in an actual loss of physical control of the facility. Releases can be reasonably expected to exceed EPA Protective Action Guideline exposure levels offsite for more than the immediate site area intentional damage or malicious acts:(1) toward site personnel or equipment that could lead to the likely failure of or: (2) that prevent effective access to equipment needed for the protection of the public. Any releases are not expected to result in exposure levels which exceed EPA Protective Action Guideline exposure levels beyond the SITE BOUNDARY site equipment because of HOSTILE ACTION.
Any releases are expected to be limited to small fractions of the EPA Protective Action Guideline exposure levels offsite response or monitoring are expected unless further degradation of safety systems occurs Control Room Evacuation HS3 Control room evacuation has been initiated and plant control cannot be established Emergency Action Level(s):
- 1. a. Control room evacuation has been initiated AND
- b. Control of the plant cannot be established in accordance with AOP-0031, Shutdown from Outside the Main Control Room, within 15 minutes HA3 Control room evacuation has been initiated Emergency Action Level(s):
1.
AOP-0031, Shutdown from Outside the Main Control Room requires Control Room evacuation HA4 FIRE or EXPLOSION affecting the operability of plant safety systems required to establish or maintain safe shutdown HU4 FIRE within the PROTECTED AREA not extinguished within 15 minutes of detection or EXPLOSION within the PROTECTED AREA 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D band is established below the RPV flange OR
- 2. RCS level cannot be monitored with a loss of RCS inventory as indicated by an unexplained rise in floor or equipment sump level, Suppression Pool level, vessel make-up rate or observation of leakage or inventory loss Loss of Decay Heat R CA3 Inability to maintain plant in cold shutdown Emergency Action Level(s):(1or 2) 1.
An UNPLANNED event results in RCS temperature > 200 °F > the specified duration in Table C2 OR 2.
An UNPLANNED event results in RCS pressure rise > 10 psig due to a loss of RCS cooling CU3 UNPLANNED loss of decay heat removal capability with irradiated fuel in the RPV Emergency Action Level(s): (1 or 2)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time.
1.
An UNPLANNED event results in RCS temperature exceeding 200°F OR 2.
Loss of all RCS temperature and RCS/RPV level indication for > 15 minutes 1 2 3 4 5 D 1 2 3 4 5 D Table C2 RCS Reheat Duration Thresholds RCS Containment Closure Duration Table R1 EAL THRESHOLD surveysconfirm that area radiation levels are below 1000 times normal* within 15 minutes of the area radiation monitor indications going full scale.
- Normal can be considered the highest reading in the past 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> excluding the current peak value.
AA3 Rise in radiation levels within the facility that impedes operation of systems required to maintain plant safety functions Emergency Action Level: (s) 1.
Dose rate > 15 mR/hr in any of the following areas requiring continuous occupancy to maintain plant safety functions:
Main Control Room CAS 1 2 3 4 5 D Fire Emergency Action Level(s):
1.
FIRE or EXPLOSION resulting in VISIBLE DAMAGE to any of the structures or areas in Table H2 containing safety systems or components or Control Room indication of degraded performance of those safety systems AREA Emergency Action Level(s): (1 or 2)
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the duration has exceeded, or will likely exceed, the applicable time.
1.
FIRE not extinguished within 15 minutes of Control Room notification or verification of a Control Room FIRE alarm in any Table H2 structure or area OR
- 2. EXPLOSION within the PROTECTED AREA To HA5 Access to a VITAL AREA is prohibited due to toxic, corrosive, asphyxiant or flammable gases which jeopardize operation of operable equipment required to maintain safe operations or safely shutdown the reactor Emergency Action Level(s):
HU5 Release of toxic, corrosive, asphyxiant or flammable gases deemed detrimental to NORMAL PLANT OPERATIONS Emergency Action Level(s) (1 or 2) 1.
Toxic, corrosive, asphyxiant or flammable gases in amounts that have or could adversely 1 2 3 4 5 D 1 2 3 4 5 D EVENTS RELATED TO ISFSI OPERATING MODES:
Removal Loss of AC Pow CA5 Loss of all offsite and all onsite AC power to emergency busses for >15 minutes Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time.
1.
Loss of all offsite and all onsite AC power to CU5 AC power capability to emergency busses reduced to a single power source for > 15 minutes such that any additional single failure would result in station blackout Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time.
1 2 3 4 5 D 1 2 3 4 5 D 1
2 3
4 5
D Intact N/A 60 minutes*
Not intact Established 20 minutes*
Not Established 0 minutes
- If and RCS heat removal system is in operation within this time frame and RCS temperature is being reduced, the EAL is not applicable.
Method GENERAL DRMS Threshold SITE AREA DRMS Threshold ALERT DRMS Threshold NOUE DRMS Threshold Main Plant Primary Secondary 4GE125 4.70E+08 Ci/sec N/A 4GE125 4.70E+07 Ci/sec N/A 4GE125 3.06E+07 Ci/sec 1GE126 2.82E-01 Ci/ml 4GE125 3.06E+05 Ci/sec 1GE126 5.26E-03 Ci/ml FB Vent Primary Secondary 4GE005 6.70E+07 Ci/sec N/A 4GE005 6.70E+06 Ci/sec N/A 4GE005 2.19E+06 Ci/sec 5GE005 2.82E-01 Ci/ml 4GE005 2.19E+04 Ci/sec 5GE005 4.65E-03 Ci/ml RW Vent Primary Secondary N/A N/A 4GE006 2.58E+06 Ci/sec 5GE006 6.84E-02 Ci/ml 4GE006 2.58E+04 Ci/sec 5GE006 6.84E-04 Ci/ml oxic or Flammable Gasses g
y
( )
NOTE: If the equipment in the stated area was already inoperable, or out of service, before the event occurred, then this EAL should not be declared as it will have no adverse impact on the ability of the plant to safely operate or safely shutdown beyond that already allowed by Technical Specifications at the time of the event.
1.
Access to Main Control Room, Auxiliary Building, or 95 Control Building is prohibited due to toxic, corrosive, asphyxiant or flammable gases which jeopardize operation of systems required to maintain safe operations or safely shutdown the reactor g
y affect NORMAL PLANT OPERATIONS OR 2.
Report by West Feliciana Parish for evacuation or sheltering of site personnel based on an offsite event HA6 Natural or destructive phenomena affecting VITAL AREAS Emergency Action Level(s): (1 or 2 or 3 or 4 or 5 or 6) 1.a. Seismic event > Operating Basis Earthquake (OBE) as indicated by:
HU6 Natural or destructive phenomena affecting the PROTECTED AREA Emergency Action Level(s):(1 or 2 or 3 or 4 or 5)
- 1. Seismic event identified by any 2 of the following:
Seismic event confirmed by activated 1 2 3 4 5 D 1 2 3 4 5 D GENERAL EMERGENCY SITE AREA EMERGENCY ALERT NOUE Confinement Boundary damage / loss E-HU1 Damage to a loaded cask CONFINEMENT BOUNDARY Emergency Action Level(s):
1.
Damage to a loaded cask CONFINEMENT BOUNDARY er p
Div I and Div II ENS busses for > 15 minutes
- 1. a. AC power capability to Div I and Div II ENS busses reduced to a single power source for > 15 minutes AND
- b. Any additional single power source failure will result in station blackout Loss of DC Power CU6 Loss of required DC power for >15 minutes Emergency Action Level(s):
NOTE: The Emergency Director should not wait until the applicable time has elapsed, but should declare the event as soon as it is determined that the condition will likely exceed the applicable time.
1.
< 105 VDC on required Vital DC busses for > 15 minutes Inadverte CU7 Inadvertent criticality Emergency Action Level(s):
1 2 3 4 5 D 1 2 3 4 5 D 1 2 3 4 5 D Natural or Destructiv Annunciator Seismic Tape Recording System Start (P680-02A-D06)
AND Event Indicator on ERS-NBI-102 is white AND Receipt of EITHER 1 OR 2:
- 1. Annunciator Seismic Event High (P680-02A-C06)
- 2. Annunciator Seismic Event High-High (P680-02A-B06) AND amber light(s) on panel NBI-101 AND
- b. Earthquake confirmed by any of the following:
Earthquake is felt in plant National Earthquake Center Control Room indication of degraded performance of systems required for safe shutdown of the plant OR 2.
Tornado striking resulting in VISIBLE DAMAGE to any of the Table H2 structures or areas containing safety systems or components or Control Room indication of degraded performance of those safety systems seismic switch as indicated by receipt of EITHER a OR b:
a.
Annunciator Seismic Tape Recording SYS Start (P680-02A-D06) b.
Event Indicator on ERS-NBI-102 is white Earthquake felt in plant National Earthquake Center OR
- 2. Tornado striking within the PROTECTED AREA boundary OR
- 3. Internal flooding that has the potential to affect safety related equipment required by Technical Specifications for the current operating mode in any Table H1 area OR
- 4. Turbine failure resulting in casing penetration or damage to turbine or generator seals OR
- 5. Severe weather or hurricane conditions with indication of SUSTAINED high winds > 74 mph within the PROTECTED AREA boundary Table H2 Structures Containing Functions or Systems Required for Safe Shutdown Reactor Standby Cooling Table H1 ent Criticality Emergency Action Level(s):
1.
UNPLANNED sustained positive period observed on nuclear instrumentation Loss of Communications CU8 Loss of all onsite or offsite communications capabilities Emergency Action Level(s): (1 or 2) 1.
Loss of all of the following onsite communication methods affecting the ability to perform routine operations:
Plant radio system Plant paging system Sound powered phones In-plant telephones OR 2.
Loss of all of the following offsite communication methods affecting the ability to perform offsite notifications:
All telephones NRC phones State of Louisiana Radio Offsite notification system and hotline 1 2 3 4 5 D ve Phenomena OR 3.
Internal flooding in Auxiliary Building 70 ft elevation resulting in an electrical shock hazard that precludes access to operate or monitor safety equipment or Control Room indication of degraded performance of those safety systems OR 4.
Turbine failure-generated PROJECTILES resulting in VISIBLE DAMAGE to or penetration of any of the Table H2 structures or areas containing safety systems or components or Control Room indication of degraded performance of those safety systems OR 5.
Vehicle crash resulting in VISIBLE DAMAGE to any of the Table H2 structures or areas containing safety systems or components or Control Room indication of degraded performance of those safety systems OR 6.
Hurricane or high SUSTAINED wind conditions > 74 mph within the PROTECTED AREA boundary and resulting in VISIBLE DAMAGE to any of the Table Reactor Building Standby Cooling Tower Auxiliary Building Diesel Generator Building Control Building Tunnels (B, D, E, F, G)
Fuel Building Table H1 Uncontrolled Flooding Threshold Area Water Level Affected Location /
Parameter Max Safe Operating Value / Indicator Aux Bldg Crescent Area 70 EL 6 inches above floor (must be verified locally)
HPCS Room 70EL 4 inches above floor (P870-51A-G4)
RHR A Room 70EL 4 inches above floor (P870-51A-G4)
RHR B Room 70EL 4 inches above floor (P870-51A-G4)
RHR C Room 70EL 4 inches above floor (P870-51A-G4)
LPCS Room 4 inches above floor hotline EIP-2-001 ATT 10 USER AID 2 Revision D EIP-2-001 REV - 24 PAGE 158 of 158 in VISIBLE DAMAGE to any of the Table H2 structures or areas containing safety systems or components or Control Room indication of degraded performance of those safety systems 70EL (P870-51A-G4)
RCIC Room 70EL 4 inches above floor (P870-51A-G4)
CONTINUOUS USE ATTACHMENT 1 PAGE 1 OF 8 AVAILABLE SAFE SHUTDOWN SYSTEMS AOP-0052 REV - 025 PAGE 9 OF 62 Fire Area:
AB-1 AB-2 AB-3 AB-4 AB-5 AB-6 AB-7 AB-10 AB-13 West Side HPCS &
MS Tunnel Standby Gas Crescent HPCS Hatch RHR B
& RWCU RHR A LPCS Hatch D-Tunnel South End Treatment B Electrical Power Div. I X
X X
X X
X Div.
II X
X X
X X
X X
Div. III X
X X
X X
X Offsite RPV Level Control HPCS (Div. III)
X X
X X
X RCIC (Div. I)
X X
X LPCS (Div. I)
X X
X X
X X
LPCI-RHR C (Div. II)
X X
X X
X X
RPV Pressure Control Div. I SRVs X
X X
X X
X Div. II SRVs X
X X
X X
X X
Decay Heat Removal RHR A Suppression Pool Cooling X
X X
X X
RHR A Alternate Shutdown Cooling X
X X
X X
RHR A Normal Shutdown Cooling RHR B Suppression Pool Cooling X
X X
X X
X RHR B Alternate Shutdown Cooling X
X X
X X
X RHR B Normal Shutdown Cooling Mech./Environ. Support Div. I Standby Service Water X
X X
X X
X Div. I HVAC Systems X
X X
X X
X Div. I Containment/RPV Monitoring X
X X
X X
X Div. II Standby Service Water X
X X
X X
X X
Div. II HVAC Systems X
X X
X X
X X
Div. II Containment/RPV Monitoring X
X X
X X
X X
Normal Service Water Equipment availability depends upon fire location in Fire Area Local Manual Action Required?
N Y
Y N
N N
Y N
N
CONTINUOUS USE ATTACHMENT 1 PAGE 2 OF 8 AVAILABLE SAFE SHUTDOWN SYSTEMS AOP-0052 REV - 025 PAGE 10 OF 62 Fire Area:
AB-14 AB-15 AB-17 AB-18 C-1 C-2 C-3 C-4 Standby Gas East Side Cont. Vent D-Tunnel Cable Chase Cable Chase Rm. North of ACU Rooms Treatment A Crescent Flt. Train Rm. Cable Chase I (NE)
II (SE)
ACU Rooms East West Electrical Power Div.
I X
X X
X X
X X
Div. II X
X partial X
X Div. III X
X X
X X
X Offsite RPV Level Control HPCS (Div. III)
X X
X X
X RCIC (Div. I)
X X
X X
LPCS (Div. I)
X X
X X
X X
X LPCI-RHR C (Div. II)
X X
X X
RPV Pressure Control Div. I SRVs X
X X
X X
X X
Div. II SRVs X
X X
X Decay Heat Removal RHR A Suppression Pool Cooling X
X X
X X
X X
RHR A Alternate Shutdown Cooling X
X X
X X
X X
RHR A Normal Shutdown Cooling X
RHR B Suppression Pool Cooling X
X X
X RHR B Alternate Shutdown Cooling X
X X
X RHR B Normal Shutdown Cooling Mech./Environ. Support Div. I Standby Service Water X
X X
1 pump 1 pump X
X Div. I HVAC Systems X
X X
X X
X X
Div. I Containment/RPV Monitoring X
X X
X X
X X
Div. II Standby Service Water X
X X
X Div. II HVAC Systems X
X X
X Div. II Containment/RPV Monitoring X
X X
X Normal Service Water Equipment availability depends upon fire location in Fire Area X
Local Manual Action Required?
N Y
N Y
Y Y
N N
N
CONTINUOUS USE ATTACHMENT 1 PAGE 3 OF 8 AVAILABLE SAFE SHUTDOWN SYSTEMS AOP-0052 REV - 025 PAGE 11 OF 62 Fire Area:
C-5 C-6 C-7 C-9 C-10 C-11 C-13E C-13W C-14 Cable Area Remainder Post-Accid.
Cable Chase Cable Chase Vestibule HVK Chiller HVK Chiller Div. II Stby.
S. of ACU of El. 70 Rad. Monit.
III (NW)
IV (SW)
(NW Corner)
East Side West Side Swgr. Rm.
Electrical Power Div.
I X
X X
X Div. II X
X X
X X
Div. III X
X X
Offsite RPV Level Control HPCS (Div. III)
X X
X RCIC (Div.
I)
X X
X LPCS (Div. I)
X X
X X
LPCI-RHR C (Div. II)
X X
X X
X RPV Pressure Control Div. I SRVs X
X X
X Div. II SRVs X
X X
X X
Decay Heat Removal RHR A Suppression Pool Cooling X
X X
X RHR A Alternate Shutdown Cooling X
X X
X RHR A Normal Shutdown Cooling RHR B Suppression Pool Cooling X
X X
X X
RHR B Alternate Shutdown Cooling X
X X
X X
RHR B Normal Shutdown Cooling Mech./Environ. Support Div. I Standby Service Water 1 pump 1 pump X
1 pump Div. I HVAC Systems X
X X
X Div. I Containment/RPV Monitoring X
X X
X Div. II Standby Service Water X
X X
X X
Div. II HVAC Systems X
X X
X X
Div. II Containment/RPV Monitoring X
X X
X X
Normal Service Water Equipment availability depends upon fire location in Fire Area Local Manual Action Required?
Y Y
N N
N N
N N
Y
CONTINUOUS USE ATTACHMENT 1 PAGE 4 OF 8 AVAILABLE SAFE SHUTDOWN SYSTEMS AOP-0052 REV - 025 PAGE 12 OF 62 Fire Area:
C-15 C-16 C-17 C-18 C-19 C-21 C-22 C-24 C-27 Div. I Stby.
Remote Control Bldg.
ENB A Batt.
ENB B Batt.
HPCS Batt.
HPCS Remainder East Pipe Swgr. Rm.
S/D Room Vent. Room
& Inv/Chgr.
& Inv/Chgr.
& Chgr. Rms.
Swgr. Rm.
of El. 116 Chase Electrical Power Div. I X
X X
X Div. II X
X X
X X
X Div. III X
X X
X Offsite RPV Level Control HPCS (Div. III)
X X
X RCIC (Div. I)
X X
X X
LPCS (Div. I)
X X
X LPCI-RHR C (Div. II)
X X
X X
X X
RPV Pressure Control Div. I SRVs X
X X
X Div. II SRVs X
X X
X X
X Decay Heat Removal RHR A Suppression Pool Cooling X
X X
X RHR A Alternate Shutdown Cooling X
X X
RHR A Normal Shutdown Cooling X
RHR B Suppression Pool Cooling X
X X
X X
X RHR B Alternate Shutdown Cooling X
X X
X X
X RHR B Normal Shutdown Cooling Mech./Environ. Support Div. I Standby Service Water X
X 1 pump X
Div. I HVAC Systems X
X X
X Div. I Containment/RPV Monitoring X
X X
X Div. II Standby Service Water X
X X
X X
X Div. II HVAC Systems X
X X
X X
X Div. II Containment/RPV Monitoring X
X X
X X
X Normal Service Water Equipment availability depends upon fire location in Fire Area Local Manual Action Required?
N N
Y N
N Y
N Y
N
CONTINUOUS USE ATTACHMENT 1 PAGE 5 OF 8 AVAILABLE SAFE SHUTDOWN SYSTEMS AOP-0052 REV - 025 PAGE 13 OF 62 Fire Area:
C-29 C-30 DG-1 DG-2 DG-3 DG-4 DG-5 DG-6 DG-7 NW Stairwell Div. II Fuel Div. III Fuel Div. I Fuel Div. II Diesel Div. III Diesel Div. I Diesel Div.II Diesel Vestibule No. 1 Storage Tk.
Storage Tk.
Storage Tk.
Gen. Room Gen. Room Gen. Room Elec. Tunnel Electrical Power Div. I X
X X
X X
X Div.
II X
X X
X X
X Div.
III X
X X
X X
X X
Offsite RPV Level Control HPCS (Div. III)
X X
X X
X X
X RCIC (Div. I)
X X
X X
X X
LPCS (Div. I)
X X
X X
X X
LPCI-RHR C (Div. II)
X X
X X
X X
RPV Pressure Control Div. I SRVs X
X X
X X
X Div. II SRVs X
X X
X X
X Decay Heat Removal RHR A Suppression Pool Cooling X
X X
X X
X RHR A Alternate Shutdown Cooling X
X X
X X
X RHR A Normal Shutdown Cooling RHR B Suppression Pool Cooling X
X X
X X
X RHR B Alternate Shutdown Cooling X
X X
X X
X RHR B Normal Shutdown Cooling Mech./Environ. Support Div. I Standby Service Water X
X X
1 pump X
X Div. I HVAC Systems X
X X
X X
X Div. I Containment/RPV Monitoring X
X X
X X
X Div. II Standby Service Water X
X X
X X
X Div. II HVAC Systems X
X X
X X
X Div. II Containment/RPV Monitoring X
X X
X X
X Normal Service Water Equipment availability depends upon fire location in Fire Area Local Manual Action Required?
N N
N N
N N
N N
N
CONTINUOUS USE ATTACHMENT 1 PAGE 6 OF 8 AVAILABLE SAFE SHUTDOWN SYSTEMS AOP-0052 REV - 025 PAGE 14 OF 62 Fire Area:
ET-1 ET-2 ET-3 ET-4 ET-5 ET-6 FB-1 MG-1 B-Tunnel B-Tunnel T-Tunnel T-Tunnel B-Tunnel C-Tunnel Fuel LFMG East (DG)
West (FB)
West El.676 West El.95 South Building Building Electrical Power Div.
I X
X X
X X
X X
Div.
II X
X X
X X
X X
Div. III X
X X
X X
X X
Offsite RPV Level Control HPCS (Div. III)
X X
X X
X X
RCIC (Div. I)
X X
X X
X X
LPCS (Div. I)
X X
X X
X X
X LPCI-RHR C (Div. II)
X X
X X
X X
X RPV Pressure Control Div. I SRVs X
X X
X X
X X
Div.
II SRVs X
X X
X X
X X
Decay Heat Removal RHR A Suppression Pool Cooling X
X X
X X
X X
RHR A Alternate Shutdown Cooling X
X X
X X
X X
RHR A Normal Shutdown Cooling RHR B Suppression Pool Cooling X
X X
X X
X X
RHR B Alternate Shutdown Cooling X
X X
X X
X X
RHR B Normal Shutdown Cooling Mech./Environ. Support Div. I Standby Service Water X
X X
X X
X X
Div. I HVAC Systems X
X X
X X
X X
Div. I Containment/RPV Monitoring X
X X
X X
X X
Div. II Standby Service Water X
X X
X X
X X
Div. II HVAC Systems X
X X
X X
X X
Div. II Containment/RPV Monitoring X
X X
X X
X X
Normal Service Water Equipment availability depends upon fire location in Fire Area Local Manual Action Required?
N Y
N N
N N
Y N
CONTINUOUS USE ATTACHMENT 1 PAGE 7 OF 8 AVAILABLE SAFE SHUTDOWN SYSTEMS AOP-0052 REV - 025 PAGE 15 OF 62 Fire Area:
PH-1 PH-2 PH-3 PH-4 PH-5 PT-1 PT-2 Stby. Cooling Stby. Cooling Remote Air Div. II SCT Div. I SCT E, F &
E-Tunnel Twr. (Div. I)
Twr. (Div. II)
Intake Room Fans Fans G-Tunnels (SWP/CCP)
Electrical Power Div. I X
X X
X X
X Div. II X
X X
X X
Div. III X
X X
X X
X X
Offsite X
RPV Level Control HPCS (Div. III)
X X
X X
X X
X RCIC (Div. I)
X X
X X
X X
LPCS (Div. I)
X X
X X
X X
LPCI-RHR C (Div. II)
X X
X X
X RPV Pressure Control Div. I SRVs X
X X
X X
X Div. II SRVs X
X X
X X
Decay Heat Removal RHR A Suppression Pool Cooling X
X X
X X
X RHR A Alternate Shutdown Cooling X
X X
X X
X RHR A Normal Shutdown Cooling RHR B Suppression Pool Cooling X
X X
X X
RHR B Alternate Shutdown Cooling X
X X
X X
RHR B Normal Shutdown Cooling Mech./Environ. Support Div. I Standby Service Water X
X X
X Div. I HVAC Systems X
X X
X X
X Div. I Containment/RPV Monitoring X
X X
X X
X Div. II Standby Service Water X
X X
X Div. II HVAC Systems X
X X
X X
Div. II Containment/RPV Monitoring X
X X
X X
Normal Service Water X
Equipment availability depends upon fire location in Fire Area Local Manual Action Required?
N N
N N
N N
N
CONTINUOUS USE ATTACHMENT 1 PAGE 8 OF 8 AVAILABLE SAFE SHUTDOWN SYSTEMS AOP-0052 REV - 025 PAGE 16 OF 62 Fire Area:
RC-2 RC-3 RC-4 RC-6 RDW-1 MS Tunnel, N Reactor Bldg Reactor Bldg Annulus Area Drywell of Imp. Wall East All Elev West All Elev East West East West Electrical Power Div. I X
X X
X Div. II X
X X
X Div. III X
X X
X X
Offsite RPV Level Control HPCS (Div. III)
X X
X X
X X
RCIC (Div. I)
LPCS (Div. I)
X X
X X
X X
LPCI-RHR C (Div. II)
X X
X X
RPV Pressure Control Div. I SRVs X
X X
X Div. II SRVs X
X X
X Decay Heat Removal RHR A Suppression Pool Cooling X
X X
X RHR A Alternate Shutdown Cooling X
X X
X RHR A Normal Shutdown Cooling RHR B Suppression Pool Cooling X
X X
X RHR B Alternate Shutdown Cooling X
X X
X RHR B Normal Shutdown Cooling Mech./Environ. Support Div. I Standby Service Water X
X X
X Div. I HVAC Systems X
X X
X Div. I Containment/RPV Monitoring X
X X
X Div. II Standby Service Water X
X X
X Div. II HVAC Systems X
X X
X Div. II Containment/RPV Monitoring X
X X
X Normal Service Water Equipment availability depends upon fire location in Fire Area Local Manual Action Required?
N N
N N
N N
N
Chemistry TR 3.4.13 RIVER BEND TR 3.4-13 Revision 5 (33i)
TR 3.4.13 CHEMISTRY TLCO 3.4.13 The chemistry of the reactor coolant system shall be maintained within the limits specified in Table 3.4.13-1.
APPLICABILITY:
At all times.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
In MODE 1, with the conductivity, chloride concentration or pH exceeding the limit specified in Table 3.4.13-1.
A.1 Restore to within limits.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> B.
Required Action A.1 and associated Completion Time not met.
OR Conductivity or chloride concentration exceeds the limit specified in Table 3.4.13-1 while in MODE 1 for > 336 hours0.00389 days <br />0.0933 hours <br />5.555556e-4 weeks <br />1.27848e-4 months <br /> in any 365 day period.
B.1 Be in Mode 2.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> C.
In MODE 2 and 3 with the conductivity, chloride concentration or pH exceeding the limit specified in Table 3.4.13-1.
C.1 Restore to within limits.
48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> (continued)
Chemistry TR 3.4.13 RIVER BEND TR 3.4-14 Revision 5 (33ii)
ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME D.
Required Action C.1 and associated Completion Time not met.
OR The identification while in MODE 1, that conductivity exceeds 10
µmho/cm at 25°C or chloride concentration exceeds 0.5 ppm D.1 Be in Mode 3.
AND D.2 Be in Mode 4.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> 36 hours E.
At all times other than MODE 1, 2 or 3, with the conductivity or pH exceeding the limit specified in Table 3.4.13-1.
E.1 Restore the conductivity and pH to within the limit.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> F.
At all times other than MODE 1, 2 or 3, with the chloride concentration exceeding the limit specified in Table 3.4.13-1.
F.1 Restore chloride concentration to within limit.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> G.
Required Action F.1 and associated Completion Time not met.
G.1 Perform an engineering evaluation to determine the effects of the out-of-limit condition on the structural integrity of the reactor coolant system.
Prior to exceeding 200 F RCS temperature.
Chemistry TR 3.4.13 RIVER BEND TR 3.4-15 Revision 39 (33iii)
SURVEILLANCE REQUIREMENTS
NOTE------------------------------------
The reactor coolant shall be determined to be within the specified chemistry limit by performance of the following:
SURVEILLANCE FREQUENCY TSR 3.4.13.1 Determine reactor coolant to be within the specified chemistry limit by analyzing a sample of the reactor coolant for chlorides.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> AND
NOTE------
When conductivity is greater than the limit in Table 3.4.13-1.
8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> TSR 3.4.13.2 Determine reactor coolant to be within the specified chemistry limit by analyzing a sample of the reactor coolant for conductivity.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.
TSR 3.4.13.3
NOTE---------------------
Not required to be met when conductivity is 1.0 mhos/cm @25°C.
Determine reactor coolant to be within the specified chemistry limit by analyzing a sample of the reactor coolant for pH.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> AND
NOTE------
When conductivity is greater than the limit in Table 3.4.13-1.
8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> TSR 3.4.13.4
NOTE--------------------
Not required to be met when obtaining in-line conductivity measurements per TSR 3.4.13.5 Record the conductivity of the reactor coolant.
Continuously Continued
Chemistry TR 3.4.13 RIVER BEND TR 3.4-16 Revision 5 (33iv)
SURVEILLANCE FREQUENCY TSR 3.4.13.5
NOTE-------------------
Not required to be met when the continuous recording conductivity monitor is operable.
Obtain an in-line conductivity measurement.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> in MODE 1, 2 or 3 AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> TSR 3.4.13.6
NOTE-----------------
Not required to be met when obtaining in-line conductivity measurements per TSR 3.4.13.5.
Perform a CHANNEL CHECK of the continuous conductivity monitor with an in-line flow cell.
7 days AND
NOTE-------
When conductivity is greater than the limit in Table 3.4.13-1.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> TABLE 3.4.13-1 REACTOR COOLANT SYSTEM CHEMISTRY LIMITS CONDUCTIVITY MODE CHLORIDES
( mhos/cm @25°C) pH 1
0.2 ppm 1.0 5.6 pH 8.6 2 and 3 0.1 ppm 2.0 5.6 pH 8.6 At all other times 0.5 ppm 10.0 5.3 pH 8.6