- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance
- Supplement, Supplement, Supplement
Results
Other: ML071210530, ML071840939, ML072830629, ML083360115, ML083540614, ML090790176, ML090790187, ML090820316, ML090820317, ML090820318, ML090820319, ML092860253, ML102930012, ML103060210, ML110200539, ML110350022, ML11187A054, ML11187A055, ML11200A052, ML11276A008, ML11286A140, ML11290A232, ML11305A021, ML12055A234, ML12055A254, ML12157A287, ML12165A684, ML13014A633, ML13161A389, ML13162A604, ML13162A616, ML14136A005, ML14192B395, ML14192B409, ML14220A317, ML15114A080, ML15114A081, ML15114A082, ML15114A083, ML15114A084, ML15114A085, ML15166A070, NL-08-023, Entrainment and Impingement at IP2 and IP3: a Biological Impact Assessment, NL-11-024, Letter from Fred Dacimo to Andrew Stuyvenberg Regarding Endangered Species Act Consultation for Indian Point Nuclear Generating Unit Nos. 2 & 3, NL-11-078, License Renewal Thermal Study Documents, NL-11-081, Clean Water Act Section 401 Water Quality Certification Waiver
|
MONTHYEARML0712105302007-04-23023 April 2007 License Renewal Application. Appendix E, Applicants Environment Report Project stage: Other ML0719900932007-06-26026 June 2007 Ltr. Michael Kaplowitz Re Incompleteness and Inaccurate License Renewal Application for Indian Point Energy Center, Units 2 and 3 Project stage: Request ML0718409392007-08-0606 August 2007 Notice of Intent to Prepare an Environmental Impact Statement and Conduct Scoping Process for License Renewal for the Indian Point Nuclear Generating Units 2 and 3 (TAC MD5411 and MD 5412) Project stage: Other ML0728901992007-09-19019 September 2007 Transcript of Indian Point License Renewal Public Meeting: Afternoon Session, September 19, 2007, Pages 1-105 Project stage: Meeting ML0728902092007-09-19019 September 2007 Transcript of Indian Point License Renewal Public Meeting: Evening Session, September 19, 2007, Pages 1-126 Project stage: Meeting ML0728306292007-09-19019 September 2007 License Renewal Application Environmental Scoping Mtg., Written Submittals from Audience - 1:30 Project stage: Other ML0728306132007-09-19019 September 2007 License Renewal Application, Environmental Scoping Meeting - September 19, 2007, Written Submittals from Audience - 7:00 Pm Project stage: Meeting ML0728508952007-10-11011 October 2007 License Renewal Environmental Scoping Meeting Project stage: Meeting ML0728510792007-10-24024 October 2007 Summary of Public Environmental Scoping Meetings Related to the Review of the Indian Point Nuclear Generating Unit Nos. 2 and 3, License Renewal Application Project stage: Meeting ML0731009852007-10-25025 October 2007 Revised Fuse Comments on Scope of Environmental Impact Statement and Scoping Process Indian Point Energy Center Unit 2 and Unit 3 Project stage: Request ML0733309312007-12-0505 December 2007 Request for Additional Information Regarding Environmental Review for Indian Point Nuclear Generating Unit Nos. 2 and 3 License Renewal Project stage: RAI ML0731104472007-12-0707 December 2007 Request for Additional Information Regarding Severe Accident Mitigation Alternatives for Indian Point Nuclear Generating Unit Nos. 2 and 3 License Renewal Project stage: RAI ML0734800712007-12-14014 December 2007 LB Memorandum (Regarding the Status of the Crorip Petition to Intervene and Section 2.335 Petition) Project stage: Request ML0800700352008-01-0404 January 2008 NRC Staffs Motion to Strike the Superceding Request for Hearing and Petition to Intervene Filed by Friends United for Sustainable Energy, USA (Fuse) Project stage: Request ML0802200732008-01-10010 January 2008 Motion of Entergy Nuclear Operations, Inc. to Strike Superceding Request for Hearing and Petition to Intervene by Friends United for Substainable Energy, USA Project stage: Request ML0803800962008-01-30030 January 2008 Supplemental Response to Request for Additional Information Regarding Environmental Review for License Renewal Application Project stage: Supplement NL-08-023, Entrainment and Impingement at IP2 and IP3: a Biological Impact Assessment2008-01-31031 January 2008 Entrainment and Impingement at IP2 and IP3: a Biological Impact Assessment Project stage: Other NL-08-028, Reply to Request for Additional Information Regarding License Renewal Application - Severe Accident Mitigation Alternatives Analysis2008-02-0505 February 2008 Reply to Request for Additional Information Regarding License Renewal Application - Severe Accident Mitigation Alternatives Analysis Project stage: Response to RAI ML12090A7912008-02-0505 February 2008 Entergy Pre-Filed Hearing Exhibit ENT000460, NL-08-028, Letter from Fred Dacimo, Entergy, to NRC Reply to Request for Additional Information Regarding License Renewal Application - Severe Accident Mitigation Alternatives Analysis (Feb. 5, 2 Project stage: Response to RAI ML0809904032008-02-28028 February 2008 Essential Fish Habitat Information Request for Docket 50-247 and 50-286; Indian Point Nuclear Generating Units 2 and 3 License Renewal, at the Village of Buchanan, Town of Cortlandt, Westchester County, Ny Project stage: Request ML0807704572008-03-0707 March 2008 Document Request for Additional Information Regarding Environmental Review for License Renewal Application - Hudson River Fisheries Program Data (Year Class Report) Project stage: Request ML0808801042008-04-0909 April 2008 Request for Additional Information, Review of License Renewal Application Project stage: RAI ML0809209832008-04-0909 April 2008 Summary of Telephone Conference Call Between NRC and Entergy Nuclear Operations, Inc., Pertaining to the Indian Point Units 2 & 3, License Renewal Application - Environmental Request for Additional Information Project stage: RAI ML0809404082008-04-14014 April 2008 Request for Additional Information Regarding the Review of the License Renewal Application for Indian Point Nuclear Generating Unit Nos. 2 & 3 Project stage: RAI NL-08-061, Reply to Document Request for Additional Information Regarding Site Audit Review of License Renewal Application2008-04-23023 April 2008 Reply to Document Request for Additional Information Regarding Site Audit Review of License Renewal Application Project stage: Request ML0810004412008-04-23023 April 2008 Revision of Schedule for the Review of the Indian Point Nuclear Generating Unit Nos. 2 and 3 License Renewal Application Project stage: Approval ML0833805912008-04-30030 April 2008 SEIS Reference - Assessment of United Water New York Supply by Rockland County Department of Health Project stage: Request NL-08-083, Reply to Request for Additional Information Regarding License Renewal Application - Refurbishment2008-05-14014 May 2008 Reply to Request for Additional Information Regarding License Renewal Application - Refurbishment Project stage: Response to RAI ML0833805612008-05-21021 May 2008 SEIS Reference - Chemicals in Sportfish and Game: 2007-2008 Health Advisories by Nydoh Project stage: Request NL-08-086, Supplemental Reply to Request for Additional Information Regarding License Renewal Application - Severe Accident Mitigation Alternatives Analysis2008-05-22022 May 2008 Supplemental Reply to Request for Additional Information Regarding License Renewal Application - Severe Accident Mitigation Alternatives Analysis Project stage: Supplement ML0833900172008-07-17017 July 2008 SEIS Reference - Online Conservation Guide for Glyptemys Muhlenbergii Project stage: Request ML0835405942008-12-0101 December 2008 NUREG-1437, Suppl. 38, Vol. 1, Dfc, Generic Environmental Impact Statement for License Renewal of Nuclear Plants, Supplement 38, Regarding Indian Point Nuclear Generating, Unit Nos. 2 and 3, Main Report Project stage: Acceptance Review ML0835406142008-12-0101 December 2008 NUREG-1437, Suppl. 38, Vol. 2, Dfc, Generic Environmental Impact Statement for License Renewal of Nuclear Plants, Supplement 38, Regarding Indian Point Nuclear Generating, Unit Nos. 2 and 3, Appendices Project stage: Other ML0833900342008-12-0202 December 2008 SEIS Reference - Significant Habitats and Habitat Complexes of the New York Bight Watershed by Fws Project stage: Request ML0833900322008-12-0202 December 2008 SEIS Reference - Westchester County Federally Listed Endangered and Threatened Species and Candidate Species by Fws Project stage: Request ML0833900302008-12-0202 December 2008 SEIS Reference - Cynoscion Regalis Gray Weakfish Project stage: Request ML0833900252008-12-0202 December 2008 SEIS Reference - Native Plant Database by Npin Project stage: Request ML0833900232008-12-0202 December 2008 SEIS Reference - Maryland Fish Facts: American Gizzard Shad by Mdnr Project stage: Request ML0833806192008-12-0303 December 2008 SEIS Reference - Status of Fishery Resources Off the Northeastern U.S.: Atlantic and Shortnose Sturgeons Project stage: Request ML0833805702008-12-0303 December 2008 SEIS Reference - Plant Fact Sheets by NCSU Project stage: Request ML0833806612008-12-0303 December 2008 SEIS Reference - Annual Drinking Water Quality Report for 2005 by Wjww Project stage: Request ML0833805532008-12-0303 December 2008 SEIS Reference - New York State Amphibian and Reptile Atlas Project by NYSDEC, Species of Turtles Found in New York Project stage: Request ML0833805452008-12-0303 December 2008 SEIS Reference - Bog Turtle Fact Sheet by NYSDEC Project stage: Request ML0833805422008-12-0303 December 2008 SEIS Reference - Peregrine Falcon by NYSDEC Project stage: Request ML0833805402008-12-0303 December 2008 SEIS Reference - Peregrine Falcon Fact Sheet by NYSDEC Project stage: Request ML0833805722008-12-0303 December 2008 SEIS Reference - Shortnose Sturgeon (Acipenser Brevirostrum) by Opr Project stage: Request ML0833805752008-12-0303 December 2008 SEIS Reference - Butterflies and Moths of North America Project stage: Request ML0833805352008-12-0303 December 2008 SEIS Reference - Bald Eagles of the Hudson River by NYSDEC Project stage: Request ML0833806322008-12-0303 December 2008 SEIS Reference - New York Quickfacts: Dutchess, Orange, Putnam, and Westchester Counties Project stage: Request ML0833806672008-12-0303 December 2008 SEIS Reference - Trinectes Maculates Fasciatus: Hogchoker Project stage: Request 2008-01-04
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 18, 2014 LICENSEE:
Entergy Nuclear Operations, Inc.
FACILITY:
Indian Point Nuclear Generating Unit Nos. 2 and 3
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON DECEMBER 4, 2014, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC. CONCERNING THE REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 LICENSE RENEWAL APPLICATION ENVIRONMENTAL REVIEW (TAC NOS. MD5411 AND MD5412)
The U.S. Nuclear Regulatory Commission (NRC) staff and representatives of Entergy Nuclear Operations, Inc., (Entergy) held a telephone conference call on December 4, 2014, to discuss and clarify the NRC staffs request for additional information (RAI) concerning the Indian Point Nuclear Generating Unit Nos. 2 and 3 license renewal application environmental review.
provides a listing of the participants and Enclosure 2 contains a listing of the RAIs discussed with Entergy, including a brief description of the status.
Entergy had an opportunity to comment on this summary.
/RA/
Michael Wentzel, Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-247 and 50-286
Enclosure:
As stated cc w/encl: Listserv
ML14344A965
- concurrence via e-mail OFFICE LA:DLR PM:RPB2:DLR BC:RPB2:DLR PM:RPB2:DLR NAME IBetts MWentzel BWittick MWentzel DATE 12/16/2014 12/18/14 12/18/14 12/18/14
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE CALL HELD ON DECEMBER 4, 2014, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC. CONCERNING THE REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 LICENSE RENEWAL APPLICATION ENVIRONMENTAL REVIEW (TAC NOS. MD5411 AND MD5412)
DISTRIBUTION:
HARD COPY:
DLR RF E-MAIL:
PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsNrrDlrRerb Resource RidsNrrDlrRsrg Resource RidsOgcMailCenter Resource MWentzel MGray, RI SKlementowicz ABurritt, RI BWittick DonaldJackson, RI DWrona GMeyer, RI DPickett MModes, RI STurk, OGC NSheehan, RI OPA BMizuno, OGC DScrenci, RI OPA DRoth, OGC DTifft, RI BHarris, OGC NMcNamara, RI SBurnell, OPA GNewman, RI DMcIntyre, OPA JSStewart, RI JWeil, OCA AmiPatel, RI
ENCLOSURE 1 TELEPHONE CONFERENCE CALL INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS DECEMBER 4, 2014 PARTICIPANTS:
AFFILIATIONS:
Steve Klementowicz U.S. Nuclear Regulatory Commission (NRC)
Michael Wentzel NRC Rick Buckley Entergy Nuclear Operations, Inc. (Entergy)
John Curry Entergy Dara Gray Entergy Rich Louie Entergy
ENCLOSURE 2 TELEPHONE CONFERENCE CALL INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 LICENSE RENEWAL APPLICATION REQUESTS FOR ADDITIONAL INFORMATION DECEMBER 4, 2014 The U.S. Nuclear Regulatory Commission (NRC) staff and representatives of Entergy Nuclear Operations, Inc., (Entergy) held a telephone conference call on December 4, 2014, to discuss and clarify the following requests for additional information (RAIs) concerning the license renewal application environmental review.
RAI 1 (Category 1 Issues)
Table 1. New Category 1 Issues Resource Category Issue
- 1.
Air Quality Air quality impacts (all plants)
- 2.
Geologic Environment Geology and soils
- 3.
Surface Water Resources Effects of dredging on surface water quality
- 4.
Terrestrial Resources Exposure of terrestrial organisms to radionuclides
- 5.
Aquatic Resources Exposure of aquatic organisms to radionuclides
- 6.
Effects of dredging on aquatic organisms
- 7.
Impacts of transmission line right-of-way (ROW) management on aquatic resources
- 8.
Human Health Human health impact from chemicals
- 9.
Physical occupational hazards
- 1. Based on the guidance in Regulatory Guide 4.2, Supplement 1, Revision 1 (RG 4.2) (June 2013), please provide a description of the affected environment and any environmental resources pertinent to the new Category 1 issues listed in Table 1 above that apply to the IP2 and IP3 site. Please include information on environmental characteristics, personnel protection programs, physical features, and, as appropriate, historical monitoring data that may be relevant to the Staffs discussion of these issues in the FSEIS supplement.
In addition to the guidance in RG 4.2, please include the following matters in your description of the affected environment for the identified resource areas:
- a. Air quality impacts: On November 3, 2009, the Commission issued a decision in the William States Lee and Bellefonte combined operating license (COL) proceedings (CLI-09-21), in which it provided guidance to the NRC staff regarding the need to include consideration of carbon dioxide and other greenhouse gas emissions (GHG) in its environmental reviews for major licensing actions under the National Environmental Policy Act.
- i. In support of NRC staffs greenhouse gas (GHG) and climate change impact analysis, please provide any significant information beyond that addressed in the GEIS. This should include, as appropriate, site-wide emission data (annual) for GHGs for the most recent 5 years. Emission data should include stationary combustion sources (e.g., generators, boilers, etc.), mobile sources (e.g. commuters, visitors, delivery vehicle, etc.) and other sources (e.g., refrigerant leakage, emissions from switchyard). Please:
- 1. identify and discuss the GHG emission sources
- 2. provide information (e.g. operating hours per year, fuel consumption and rates, and energy rating as applicable for each source) used to support the GHG emission values provided; ii. State whether Entergy has received any Notices of Violation for the most recent 5 years from the New York State Department of Environmental Conservation (NYSDEC) associated with IP2 and IP3 air permits (3-5522-00011/00026 and 3-5522-000105/00009)? If, so please identify and summarize the violations and any corrective actions taken.
iii. Describe the compliance history associated with the IP2 and IP3 air permits for the most recent 5 years.
- b. Effects of dredging on surface water quality: Please provide a summary discussion of dredging practices conducted in the vicinity of surface water intakes, discharge structures, or shoreline structures, and of associated dredge spoil disposal practices. Consider activities conducted over the past 5 years and identify methods, frequency, and whether associated sediment and/or water quality analyses are performed (and summarize results). Provide copies of current, applicable U.S. Army Corps of Engineers (USACE) or NYSDEC permits which govern Entergys dredging and discharge activities.
- c. Effects of dredging on aquatic organisms: Please provide a written discussion of the effects on aquatic organisms due to dredging conducted in the vicinity of IP2 and IP3 surface water intakes, discharge structures, and shoreline structures. Consider dredging activities conducted over the past 5 years. Also, please include a discussion of any biological studies of species, populations, or communities that are potentially affected by dredging operations near Indian Point, including the stated purpose, methods, results, and discussion of those studies. If the USACE or NYSDEC permits assessed the environmental impacts of dredging, please provide copies of those assessments.
- d. Human health impact from chemicals: Please provide a summary discussion of the nonradioactive chemical management program and procedures for the use, storage, and discharge of chemicals and sanitary wastes at the site to minimize the impacts to human health.
- e. Physical occupational hazards: Please provide a summary discussion of occupational safety program.
- 2. Please provide an evaluation of any new and significant information of which you are aware that pertains to these issues, beyond the information addressed in the GEIS, regarding the environmental impacts of IP2/IP3 license renewal.
RAI 2 (Category 2 Issues)
Table 2. New Category 2 Issues Resource Category Issue
- 1.
Groundwater Resources Radionuclides released to groundwater
- 2.
Terrestrial Resources Effects on terrestrial resources (non-cooling system impacts)
- 3.
Environmental Justice Minority and low-income populations
- 4.
Cumulative Impacts Cumulative impacts
- 1. Based on the guidance in RG 4.2, please provide relevant information and an analysis of the new Category 2 issues listed in Table 2 above. To the extent that an issue may have been reviewed previously in the 2010 FSEIS or the 2013 FSEIS supplement, you may identify and incorporate the relevant information that was previously reviewed in your response, and provide any additional information needed to satisfy the guidance in RG4.2. Further, please provide an evaluation of any new and significant information regarding the affected environment and the environmental impacts of license renewal of which you are aware, beyond the information considered in the 2010 FSEIS or the 2013 FSEIS supplement.
Discussion:
Entergy requested clarification as to whether or not the NRC staff was requesting information pertaining to hazardous air pollutants in question 1.a of RAI 1. Entergy noted that information pertaining to hazardous air pollutants had been requested in similar RAIs issued for other environmental reviews. The NRC staff confirmed that it was not requesting information on hazardous air pollutants. Entergy stated that it understood the NRC staffs request and requested a 90-day response time from the date of the letter.