ML14027A217

From kanterella
Jump to navigation Jump to search

Schedule Revision for Environmental Review of Davis-Besse Nuclear Power Station License Renewal Application
ML14027A217
Person / Time
Site: Davis Besse 
Issue date: 01/30/2014
From: John Lubinski
Division of License Renewal
To: Lieb R
FirstEnergy Nuclear Operating Co
Elaine Keegan 301-8517
References
TAC ME4613
Download: ML14027A217 (4)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 30, 2014 Mr. Raymond A. Lieb, Site Vice President FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station Mail Stop A-DB-3080 5501 North State Route 2 Oak Harbor, OH 43449-9760

SUBJECT:

SCHEDULE REVISION FOR THE ENVIRONMENTAL REVIEW OF THE DAVIS-BESSE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION (TAC NO. ME4613)

Dear Mr. Lieb:

By letter dated August 27, 2010, FirstEnergy Nuclear Operating Company submitted an application pursuant to Title 1 0 of the Code of Federal Regulations ( 1 0 CFR) Part 51 and 10 CFR Part 54, to renew operating license NPF-003 for the Davis-Besse Nuclear Power Station, Unit 1 (Davis-Besse), for review by the U.S. Nuclear Regulatory Commission (NRC) staff. This letter is to inform you of a change in the environmental review schedule for the Davis-Besse license renewal review.

Enclosed is the NRC staff's revised environmental review schedule for the Davis-Besse license renewal application. The draft Supplemental Environmental Impact Statement (SEIS) is in the final stages of review and is being prepared for publication. Due to the current and projected workload of the NRC's publishing resources, the projected date for publication of the draft SEIS is being revised from January 2014, to February 2014. The new date for publishing the final SEIS is being revised from July 2014, to September 2014, to allow adequate time for the NRC staff to address public comments anticipated on the draft SEIS.

If you have any questions on the environmental schedule, please contact Ms. Elaine Keegan, project manager for the Davis-Besse license renewal applica *on environmental review by telephone at 301-415-8517 or by e-mail at =E.:.:::Ia::.:..in.:.:::e:.:.:..k.:.:::e:...:::e=~..:...:.;..:::..:.o::z.:~

Docket No. 50-346

Enclosure:

Revised Environmental Review Schedule cc w/encl: Listserv i, Director Division of License Renewal Office of Nuclear Reactor Regulation

ML14027A217 Sincerely, IRA/

John W. Lubinski, Director Division of License Renewal Office of Nuclear Reactor Regulation

  • concurred via email OFFICE LA: DLR/RPB2*

PM:DLR/RPB2 BC: DLR/RPB2 D:DLR NAME I King EKeegan BWittick LJames for JLubinski DATE 01/27/14 01/27/14 01/28/14 01/30/14

Letter toR. Lieb from J. Lubinski dated January 30, 2014

SUBJECT:

SCHEDULE REVISION FOR THE ENVIRONMENTAL REVIEW OF THE DAVIS-BESSE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION (TAC NO ME4613)

DISTRIBUTION:

E~MAIL:

PUBLIC RidsNrrDir Resource RidsNrrDirRpb1 Resource RidsNrrDirRpb2 Resource RidsNrrDirRarb Resource RidsNrrDirRapb Resource RidsNrrDirRasb Resource RidsNrrDirRerb Resource RidsNrrDirRpob Resource RidsNrrDraApla Resource EKeegan JUri be BWittick BHarris, OGC EBrown A Wang MMahoney DMclntyre, OPA VMitlyng,OPA TRiley,OCA EWilliamson, OGC RRihm, EDO JCameron, Rill

DAVIS-BESSE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION UPDATED ENVIROMENTAL REVIEW SCHEDULE Milestones Schedule Date Receive license renewal application (LRA) 08/30/2010 Publish Federal Register notice (FRN) ~ LRA receipt and 09/17/2010 availability Publish FRN ~ LRA acceptability and opportunity for hearing 10/20/2010 Public Meeting - License Renewal Process and Environmental 11/04/2010 Scoping Deadline for filing hearing requests and petitions for intervention 12/24/2010 Audit - scoping and screening methodology 01/24/2011 Audit - aging management programs (AMPs) 02/14/2011 Inspection - scoping, screening, and AMPs 04/2011 Safety requests for additional information (RAis)- Issued 04/29/2011 Safety RAis - first round responses received 05/30/2011 Issue draft supplemental environmental impact statement 02/2014 (SEIS)

Public Meeting ~ Draft SEIS 03/2014 End of comment period for the draft SEIS 03/2014 Issue safety evaluation report (SER) with open items(s) 7/2012 Advisory Committee on Reactor Safeguards (ACRS) 09/19/2012 subcommittee meeting on SER with open item(s)

Issue SER 9/2013 ACRS second subcommittee meeting on SER 10/2013 ACRS full committee meeting on SER 12/2013 Issue final SEIS 09/2014 Office Nuclear Reactor Regulation Decision TBD Commission Decision (hearing pending)

TBD Actual Date 08/30/2010 09/20/2010 10/25/2010 11/04/2010 12/24/2010 01/24/2011 02/14/2011 04/25/2011 04/29/2011 05/30/2011 07/31/2012 09/19/2012 09/03/2013 TBD TBD